Attachment #2 HDR Riverwalk Basis of_Design_(15%)-Plans_2020-06-30.pdf
PDF 4 MB Posted
- Attached to
- Boardwalk construction
- Solicitation number
- IFB-114989
- Issued by
- Covington City, Virginia
About this file
This document is a 15% Basis of Design Plans set prepared by HDR Engineering Inc. for the City of Hopewell, Virginia Department of Development, dated June 30, 2020, detailing Phase 2 of the Hopewell Riverwalk Connector project (DCR RTP # VRT-316-D-170). The design plans include approximately 241 linear feet of covered timber riverwalk with an 8-foot 8-inch width, a Phase 2 overlook expansion, concrete plaza areas, asphalt and concrete pathways, and associated planting beds with trees and groundcover. The scope encompasses connections to existing dock infrastructure, integration with the Virginia American Water (VAW) boardwalk system, and installation of timber canopy structures with 8-inch diameter pilings. The plans feature detailed construction details across multiple sheets (L-901 through L-906), site plan enlargements, and specifications for timber components including 2"x12" girders, 2"x10" joists, 2"x8" rails, and 8"x8" posts. The design includes provisions for future phase expansion and pipe extensions, with all work subject to City of Hopewell Department of Development permits and Virginia Department of Transportation specifications for right-of-way construction.
The plans establish comprehensive construction requirements including geotechnical engineering services monitoring during engineered fill placement with minimum 95% compaction density for all fill zones exceeding two feet in elevation, complete subgrade inspection and proofrolling with 10-ton trucks prior to pavement placement, and Call 811 utility locating procedures 48 hours before excavation. Pavement design specifications mandate residential street standards with 6 inches of 21A aggregate base, 3.5 inches of BM-25 base course asphalt, and 2 inches of SM-9.5A surface course asphalt, subject to CBR soil sampling at 500-foot intervals or at grade changes. All work in the public right-of-way requires Department of Public Works permits, pre-construction conferences, utility clearance, and compliance with VDOT I&I LD-94 storm sewer standards using reinforced tongue and groove concrete pipe (minimum Class III). Trench restoration for utility cuts requires asphalt pavement thickness of 1.5 times the existing section or minimum 8 inches, with over-milling of adjacent surface course a minimum 1.25 inches beyond each trench wall. The contractor bears responsibility for utility relocation costs, environmental compliance under Section 404 of the Clean Water Act and Section 10 of the Rivers and Harbors Act, protection of VAW water intake infrastructure, and compliance with the Chesapeake Bay Preservation Act and Virginia Coastal Zone Management Program requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
15% PLANS
RIVERWALK CONNECTOR (RIVERWALK PHASE 2)
CITY OF HOPEWELL, VA
DCR RTP # VRT-316-D-170
SHEET INDEX
ENGINEER: HDR ENGINEERING INC. OF VIENNA, VA
PRIMARY: BRIAN MELI, PE
PHONE: (571)327-5891
EMAIL: BRIAN.MELI@HDRINC.COM
CONTACTS
AERIAL SITE MAP
W
E
S
T
R
A
N
D
O
L
P
H
D
SITE
APPOMATTOX RIVER
CITY OF HOPEWELL
OWNER/DEVELOPER
JUNE 30, 2020
G-001
L-101
L-102
L-901
L-902
L-903
L-904
L-905
L-906
DEPARTMENT OF DEVELOPMENT
ALL MATERIALS AND CONSTRUCTION WITHIN THE PUBLIC RIGHT OF
WAY SHALL BE IN ACCORDANCE WITH CURRENT VIRGINIA
DEPARTMENT OF TRANSPORTATION SPECIFICATIONS
LAND USE PERMITS MUST BE OBTAINED FROM THE CITY OF
HOPEWELL, DEPARTMENT OF DEVELOPMENT - BUILDING CODE PRIOR
TO BEGINNING ANY CONSTRUCTION WITHIN THE EXISTING
RIGHT-OF-WAY (INCLUDING ACCESS).
THE CONTRACTOR SHALL VERIFY THE ELEVATIONS OF ALL POINTS OF
CONNECTION OR PROPOSED WORK TO EXISTING CURBS, SANITARY
LINES, WATER LINES, ETC., PRIOR TO CONSTRUCTION.
UPON DISCOVERY OF SOILS THAT ARE UNSUITABLE FOR
FOUNDATIONS, SUBGRADES, OR OTHER ROADWAY CONSTRUCTION
PURPOSES, THE CONTRACTOR SHALL IMMEDIATELY CONTACT A
GEOTECHNICAL ENGINEER AND CITY OF HOPEWELL, DEPT. OF
DEVELOPMENT. THESE AREAS SHALL BE EXCAVATED BELOW PLAN
GRADE AS DIRECTED BY THE GEOTECHNICAL ENGINEER, BACKFILLED
WITH SUITABLE MATERIAL AND COMPACTED IN ACCORDANCE WITH
CURRENT VDOT SPECIFICATIONS.
ALL STORM SEWER DESIGN AND CONSTRUCTION TO BE IN
ACCORDANCE WITH VDOT I & I LD-94 (D) 121.13.
ALL STORM SEWER PIPE SHALL BE REINFORCED TONGUE AND
GROOVE CONCRETE PIPE IN ACCORDANCE WITH ASTM-C-76. PIPE
WITHIN THE RIGHT OF WAY SHALL BE A MINIMUM CL- III OR
GREATER IN ACCORDANCE WITH CURRENT VDOT STANDARDS AND
SPECIFICATIONS.
ALL PRE-CAST UNITS SHALL BE VDOT APPROVED. CERTIFICATION
AND VDOT STAMP WILL BE REQUIRED ON ALL UNITS.
THE DEVELOPER IS RESPONSIBLE FOR FURNISHING AND INSTALLING
STOP SIGNS AT STREET INTERSECTIONS.
DESIGN CHANGES, SPECIFIED MATERIALS CHANGES AND/OR FIELD
CHANGES FROM THE APPROVED PLANS NEED TO BE RESUBMITTED TO
THE CITY ENGINEER PRIOR TO PROCEEDING WITH THE WORK. A
LETTER OF EXPLANATION SHALL ACCOMPANY THE REVISED PLANS
AND/OR DRAINAGE CALCULATIONS, WHICH MUST BE SUBMITTED, TO
CITY OF HOPEWELL, DEPT. OF DEVELOPMENT FOR REVIEW AND
APPROVAL BY THE CITY ENGINEER.
CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF ALL
UNDERGROUND UTILITIES SHOWN ON PLANS IN AREAS OF
CONSTRUCTION PRIOR TO STARTING WORK. CONTACT ENGINEER
IMMEDIATELY IF LOCATION IS DIFFERENT FROM THAT SHOWN ON
PLAN. IF THERE APPEARS TO BE A CONFLICT, AND/OR UPON
DISCOVERY OF ANY UTILITY NOT SHOWN ON THIS PLAN, CALL MISS
UTILITY OF CENTRAL VIRGINIA AT 1-800-552-7001. THE DEVELOPER
SHALL BE RESPONSIBLE FOR THE RELOCATION OF ANY UTILITY
WITHIN EXISTING AND/OR RIGHT OF WAY REQUIRED BY THE
DEVELOPMENT.
CITY OF HOPEWELL, DEPT. OF DEVELOPMENT APPROVAL OF
CONSTRUCTION PLANS DOES NOT PRECLUDE THE RIGHT TO REQUIRE
ADDITIONAL FACILITIES AS DEEMED NECESSARY FOR ACCEPTANCE OF
THE ROADS INTO THE CITY'S SECONDARY ROAD SYSTEM.
A PRIME COAT SEAL BETWEEN THE AGGREGATE BASE AND BITUMINOUS
CONCRETE WILL BE REQUIRED AT A RATE OF 0.30 GALLONS PER
SQUARE YARD (REC-250 PRIME COAT) PER VDOT STANDARDS AND
SPECIFICATIONS.
THE SCHEDULING OF AGGREGATE BASE INSTALLATION AND
SUBSEQUENT PAVING ACTIVITIES SHALL ACCOMMODATE FORECAST
WEATHER CONDITIONS PER SECTION 315 OF THE VDOT ROAD AND
BRIDGE SPECIFICATIONS.
APPROVAL OF A DETAILED CONSTRUCTION
SEQUENCING/MAINTENANCE OF TRAFFIC NARRATIVE FOR THE WORK
ZONE IS A PREREQUISITE FOR ISSUANCE OF A LAND USE PERMIT
ALLOWING ACCESS TO AND CONSTRUCTION WITHIN RIGHT OF WAY.
GEOTECHNICAL NOTES
FOR THE CITY OF HOPEWELL DEPARTMENT OF PUBLIC WORKS
AND COMMUNITY DEVELOPMENT
ENGINEERED FILL
1. ALL CONTROLLED FILL ZONES ARE TO BE MONITORED BY A FULL TIME
GEOTECHNICAL ENGINEERING SERVICES FIRM.
2. ENGINEERED FILLS SHALL BE PROPERLY PLACED ACCORDING TO THE
RECOMMENDATIONS OF THE GEOTECHNICAL ENGINEER.
3. ALL SUMMARY REPORTS FROM THE GEOTECHNICAL ENGINEER REPRESENTING
THE PROJECT MUST STATE HIS PROFESSIONAL OPINION ON THE
SATISFACTORILY COMPLETED PHASES OF CONSTRUCTION, SUCH AS; SLOPE
CUTS, SUBDRAINAGE SYSTEMS, PREPARATION OF SUBGRADES AND
COMPACTION OF EARTH FILLS.
4. NO FILLS SHALL HAVE ZONES THAT EXCEED TWO (2) FEET IN ELEVATION
WITHOUT CONDUCTING COMPACTION TEST AND OBTAINING RESULTS OF 95% OR
GREATER.
5. THE GEOTECHNICAL ENGINEER MUST SUBMIT A DETAILED ANALYSIS, ITEMIZING
THE FIELD DENSITY TEST RESULTS. THIS REPORT SHALL BE ACCOMPANIED WITH
A COPY OF THE SITE PLAN SHEET AND INDICATE THE TEST LOCATIONS AND
ELEVATIONS. THE GEOTECHNICAL ENGINEER MUST PROVIDE ENOUGH
DESIGNATED TESTING IN ALL FILL ZONES TO ADEQUATELY EXAMINE AND
CERTIFY THE INTEGRITY OF THE FILL.
6. THE GEOTECHNICAL ENGINEER MUST SUBMIT A CERTIFIED BUILDING PAD
REPORT FOR EACH FILL PAD LOCATION. THIS REPORT SHALL PROFILE THE FILL
MATERIAL PLACEMENT AND PROVIDE THE COMPACTION TEST RESULTS. ALL
REPORTS WILL BE ACCOMPANIED BY THE SITE PLAN, INDICATING THE TEST
LOCATIONS AND ELEVATIONS.
7. NO BUILDING PADS IN FILL ZONES WILL HAVE STRATUMS EXCEEDING TWO (2)
FEET IN ELEVATION WITHOUT TEST VERIFYING DENSITY.
8. THESE GEOTECHNICAL NOTES SHALL IN NO WAY LESSEN THE REQUIREMENTS
OF THE SUBMITTED SOILS REPORT.
ROAD SUBGRADE
1. INSPECTION AND APPROVAL OF THE SUBGRADE WILL BE REQUIRED PRIOR TO
THE PLACEMENT OF THE APPROVED PAVEMENT SECTION MATERIAL.
2. ANY CLAY DEPOSITS IN THE TOP TWO FEET OF THE SUBGRADE MUST BE
REMOVED OR ADDRESSED AS RECOMMENDED BY THE GEOTECHNICAL
ENGINEER.
3. SUBGRADE APPROVAL SHALL BE ACCOMPANIED BY THE SUPPORTING
DOCUMENTATION VERIFYING DENSITY TEST RESULTS OF 95% OR GREATER.
THE ENTIRE SUBGRADE WILL HAVE BEEN PROOFROLLED IN THE PRESENCE
OF THE SITE INSPECTOR AND GEOTECHNICAL REPRESENTATIVE.
PROOFROLLING SHALL BE A RUBBER TIRE VEHICLE SUCH AS A LOADED TEN
(10) TON TRUCK OR APPROVED COMPACTION EQUIPMENT.
THE FINAL SUBGRADE SHALL BE APPROVED BY THE GEOTECHNICAL
ENGINEER AND SITE INSPECTOR BEFORE PLACEMENT OF PAVEMENT
SECTION MATERIALS.
RESIDENTIAL STREET PAVEMENT SECTIONS
1. ALTERNATE EQUIVALENT PAVEMENT SECTIONS MAY BE SUBSTITUTED FOR THE
CITY STANDARD PAVEMENT SECTION DESIGN WHEN PROPER METHODS OF
SUBGRADE SOILS ANALYSIS ARE CONDUCTED AND WITH THE APPROVAL OF THE
CITY ENGINEER.
2. CBR SAMPLING OF THE SUBGRADE SOILS FOR FINAL PAVEMENT DESIGN MUST BE
COORDINATED BY THE OWNER, THROUGH THE GEOTECHNICAL ENGINEER AND
VERIFIED BY THE ASSIGNED SITE INSPECTOR DURING THE CONSTRUCTION
PHASE.
FINAL PAVEMENT DESIGN SHALL BE CONDUCTED ON AN APPROVED REVEAL
AND SAMPLE OF THE SUBGRADE SOILS. THE SOIL SAMPLE TEST SHALL BE
MADE AT EACH INTERSECTION, CHANGES IN SUBGRADE SOILS, AND AT A
MAXIMUM SPACING OF 500 FEET. SAMPLES CAN BE PULLED WHEN THE
SUBGRADE PREPARATION IS AT ROUGH GRADE, WHICH IS DEFINED AS
WITHIN 6 INCHES OF FINAL GRADE ELEVATION. A MINIMUM OF TWO (2) CBR
SAMPLES WILL BE REQUIRED FOR ANY CUL-DE-SAC OR DEAD END STREET
LESS THAN 500 IN LENGTH.
TEST SPACING AND METHODS MUST FOLLOW THE APPROVED GUIDELINES
SET FORTH AND/OR AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER.
THE FINAL ALTERNATE EQUIVALENT PAVEMENT DESIGN MUST BE SUBMITTED
TO THE DPW CITY ENGINEER FOR APPROVAL. THE SUBMISSION WILL BE
ACCOMPANIED BY THE SUPPORTING GEOTECHNICAL REPORT AND DESIGNED
BY A PAVEMENT ENGINEER.
CLARIFICATION NOTE: PAVEMENT SECTIONS SHALL BE VERIFIED AS
ADEQUATE BASED ON CBR SAMPLING AND VDOT PAVEMENT DESIGN
FORMULAS FOR RESIDENTIAL STREETS. THE SUBMITTED ALTERNATE
EQUIVALENT DESIGN SECTION SHALL NOT BE REDUCED BELOW THE CITY'S
INDICATED RANGES. THE CITY ENGINEER MUST PRE-APPROVE ANY
ALTERNATE EQUIVALENT PAVEMENT DESIGN SECTION SUBMISSIONS
RESIDENTIAL STREET SECTIONS - BAR NO SPECIAL DESIGN SUBMISSION
AND APPROVAL BY THE CITY ENGINEER , THE REQUIRED MINIMUM
DESIGN THICKNESS OF THE AGGREGATE BASE (6”, 21A), BASE COURSE
ASPHALT (3.5”, BM-25) AND SURFACE COURSE ASPHALT (2”,SM-9.5A) AS
SHOWN IN THE STREET STANDARDS ILLUSTRATIONS.
ENGINEERED PAVEMENT SECTION DESIGN THICKNESS IS BASED ON A CBR
VALUE OF TEN, AND MAY BE INCREASED OR DECREASED AS ALLOWED BY
THE STANDARDS. IT SHALL NOT BE DECREASE BELOW THE CITY OF
HOPEWELL MINIMUM DESIGN STANDARD OF 6 INCHES OF 21A AGGREGATE
BASE, 2 INCHES OF SM-9.5A BASE COURSE ASPHALT, AND 1.5 INCHES OF
SM-9.5A SURFACE/TOP COURSE ASPHALT”
(LAST REVISION 6/14/07: JEB/CE)
CONSTRUCTION NOTES FOR PLAN & PERMIT PACKAGE ATTACHMENTS: CITY OF HOPEWELL ATTACHMENT: UTILITY “WORK IN THE CITY'S RIGHT-OF-WAYS”
FROM: DEPARTMENT OF PUBLIC WORKS - OFFICE OF THE CITY ENGINEER
1. ALL CUTS IN THE STREETS AND SIDEWALKS SHALL BE PERFORMED UNDER A PERMIT AND MONITORED BY THE DPW PERMIT INSPECTOR.
2. WORK SHALL NOT COMMENCE UNTIL THE PERMIT INSPECTOR HAS BEEN NOTIFIED, A PRE-CONSTRUCTION CONFERENCE HELD AND MISS UTILITY CLEARS.
3. CUTS SHALL BE AS CLEAN AND STRAIGHT AS POSSIBLE, WITH NO OUTLINE DIMENSIONS LESS THAN 3 FEET WITHOUT SPECIAL APPROVAL OF THE DEPARTMENT'S INSPECTOR.
4. THE DETAILS OF TRENCHING CUTS FOR UTILITY STRIPS MUST BE SHOWN IN A TYPICAL SECTION ON THE DRAWINGS OR PROVIDED IN A SUBMITTAL WITH CONSTRUCTION NOTES SPECIFYING WIDTHS, DEPTHS, METHODS, MATERIALS, COMPACTION REQUIREMENTS AND PAVEMENT RESTORATION OR ABIDING BY THE DPW ATTACHMENT STANDARD.
5. ALL ASPHALT PAVEMENT RESTORATION THICKNESS SHALL BE 1 1/2 TIMES THE EXISTING SECTION OR A MINIMUM OF 8-INCHES WHICHEVER IS GREATER. SEE THE DPW TRENCH RESTORATION
ILLUSTRATION FOR THE TYPICAL CONFORMANCE STANDARDS. NOTE: DPW HAS A THIN PAVEMENT SECTION RESTORATION DETAIL FOR ASPHALT PAVEMENTS 3-INCHES OR LESS. THESE ARE
PAVEMENT SECTIONS THAT CAN'T BE OVER-MILLED DUE TO THICKNESS LIMITATIONS. THE PERMITTEE SHOULD SEE THE DPW CONSTRUCTION INSPECTOR TO OBTAIN THIS SPECIAL RESTORATION
DETAIL.
6. THE FINAL RESTORATION ON OPEN TRENCH CUTS REQUIRES THE DISTURBED ASPHALT PAVEMENT ZONE TO BE A SQUARE POINTED OFF AND STRAIGHT LINE. THE AREA OF PAVEMENT RESTORATION
IS TO BE FULLY ENVELOPED BY THE FINAL SURFACE COURSE REPAIRS. THE ADJOINING SURFACE/TOP COURSE LAYER IS TO BE OVER-MILLED A MINIMUM DEPTH OF
1.25 INCHES OR MORE, A MINIMUM DISTANCE OF ONE FOOT BEYOND EACH SIDE OF THE TRENCH WALL. THIS STEP OUT IS TO OCCUR ALONG THE ENTIRE TRENCH LINE RUN AND/OR SQUARED
POINTED AREA. CUTS INVOLVING CONTINUOUS NETWORK RUNS, WHICH EXCEED 350 FEET IN LENGTH OR TYPICALLY OVER ONE FULL CITY BLOCK, WILL BE CONSIDERED MULTIPLE BLOCK CUTS. ON
MULTIPLE BLOCK CUT ZONES, THE OVER MILLING OF THE TRENCH LINE AND ADJOINING SURFACE COURSE LAYER MUST BE DONE WITH TYPICAL HIGH PRODUCTION ROADWAY COLD PLANNING
EQUIPMENT. IN MULTIPLE BLOCK RESTORATION CASES, WHERE THE HIGH PRODUCTION COLD PLANNER IS REQUIRED, FINAL PAVING SHALL BE DONE BY A HIGH PRODUCTION HIGHWAY PAVER.
7. PERMITTEE MUST PROVIDE AND COORDINATE THE NECESSARY GEOTECHNICAL SERVICES FROM A QUALIFIED FIRM TO INSURE COMPACTION APPROVAL. APPROVAL OF IN-PLACE MATERIAL MUST BE
FOLLOWED UP WITH A WRITTEN SUMMARY REPORT. COMPACTION REQUIREMENTS WILL BE REVIEWED FOR APPROVAL BY THE CITY ENGINEER OR HIS REPRESENTATIVE.
8. ALL DISTURBED SIDEWALK AND CURB SHALL BE REPAIRED AND REPLACED IN ACCORDANCE WITH CITY STANDARDS.
9. ALL UTILITY CUTS ARE TO BE EXAMINED AND APPROVED BY THE APPROPRIATE UTILITY INSPECTOR/REPRESENTATIVE.
10. ALL ENCROACHMENTS MUST BE SATISFIED BY ORDINANCE.
PAVEMENT DESIGN - CITY OF HOPEWELL
DESIGNS FOR “RESIDENTIAL SUBDIVISIONS” AND “NON-RESIDENTIAL” ROAD PAVEMENTS
1. RESIDENTIAL- THE REQUIRED DESIGN THICKNESS OF THE AGGREGATE BASE (6”, 21A), BASE COURSE ASPHALT (3.5”, BM-25) AND SURFACE COURSE ASPHALT (2”, SM-9.5A) ARE SHOWN IN THE STREET
STANDARDS ILLUSTRATIONS. PAVEMENT SECTION DESIGN THICKNESS IS BASED ON A CBR VALUE OF TEN AND MAY BE INCREASED OR DECREASED AS ALLOWED BY THE STANDARDS. IT SHALL NOT
BE DECREASE BELOW THE CITY OF HOPEWELL'S MINIMUM DESIGN STANDARD OF 6 INCHES OF 21A AGGREGATE BASE, 2 INCHES OF SM-9.5A BASE COURSE ASPHALT AND 1.5 INCHES OF SM-9.5A
SURFACE/TOP COURSE ASPHALT.
2. ALTERNATE EQUIVALENT PAVEMENT SECTIONS MAY BE SUBSTITUTED FOR THOSE CALLED FOR IN THE STANDARDS. THE APPROVAL PROCEDURES CALL FOR A QUALIFIED PAVEMENT ENGINEER TO
REFERENCE AND FOLLOW THE ESTABLISHED VIRGINIA DEPARTMENT OF TRANSPORTATION GUIDELINES IN THEIR PAMPHLET ENTITLED, “PAVEMENT DESIGN GUIDE FOR SUBDIVISION AND
SECONDARY ROADS", YEAR 2000 EDITION, AS AMENDED. ALTERNATE PAVEMENT SECTIONS MUST BE PRE-APPROVED BY THE CITY ENGINEER. NOTE THE MINIMUM CITY OF HOPEWELL RESIDENTIAL
PAVEMENT SECTION DESCRIBED ABOVE.
3. NON-RESIDENTIAL STREET PAVEMENT SECTIONS MUST MEET THE MINIMUM DESIGN THICKNESS OF 8 INCHES OF 21A BASE AGGREGATE, 6 INCHES BM-25 BASE COURSE ASPHALT AND 2 INCHES OF
SM-9.5A SURFACE COURSE ASPHALT. ANY REQUESTED REDUCTIONS IN THIS DESIGN MUST BE FULLY SUPPORTED BY A COMPREHENSIVE ENGINEERING ANALYSIS.
4. NO REDUCTIONS IN THE MINIMUM PAVEMENT SECTION DESIGN THICKNESS (8 INCHES 21A BASE AGGREGATE, 6 INCHES BM-25 BASE COURSE ASPHALT AND 2 INCHES OF SM-9.5A SURFACE COURSE
ASPHALT) WILL BE CONSIDERED IN THE DOWNTOWN, ARTERIAL STREETS, MAJOR COLLECTORS AND/OR ANY OTHER MAJOR CONNECTION STREETS.
5. DESIGNATED DOWNTOWN AREAS, HEAVY COMMERCIAL ZONES, PARTICULARLY HIGH VOLUME BUS ROUTES, TURNING LANES, BUS BAYS AND MAJOR INDUSTRIAL ZONES WILL REQUIRE A HEAVY
DUTY PAVEMENT SECTIONS. HEAVY DUTY IS DESCRIBED AS A MINIMUM OF 8 INCHES OF 21A AGGREGATE BASE, WITH 8 INCHES OF BM-25 BASE COURSE ASPHALT AND 2 INCHES OF SM-9.5A SURFACE
COURSE ASPHALT. NO REDUCTIONS OF THIS PAVEMENT SECTION WILL BE ALLOWED IN SO DESIGNATED ZONES.
6. AS PER DIRECTION OF THE CITY ENGINEER OR THE DIRECTOR, THE PUBLIC WORKS PERMITTING REQUIREMENTS MAY DESIGNATE SPECIFIC ANTI-RUTTING TYPES OF ASPHALT MIX DESIGNS
REQUIREMENTS (I.E.SM-9.5D/SM-9.5E) THAT WILL BETTER SUIT PROBLEM CONDITIONS AND/OR BETTER SERVE LOCATIONS WITH CERTAIN TYPES AND VOLUMES OF TRAFFIC.
(LAST AMENDED 04/16/08 JEB/CE)
VA 811
THE CONTRACTOR SHALL CALL 811 48 HOURS PRIOR TO THE START
OF EXCAVATION. CONTRACTOR SHALL VERIFY LOCATION AND
ELEVATION OF ALL UNDERGROUND UTILITIES SHOWN ON PLANS IN
AREAS OF CONSTRUCTION PRIOR TO STARTING WORK. CONTACT THE
ENGINEER IMMEDIATELY IF THE LOCATION OR ELEVATION IS
DIFFERENT FROM THAT SHOWN ON THE PLAN, IF THERE APPEARS TO
BE A CONFLICT, AND/OR UPON DISCOVERY OF ANY UTILITY NOT
SHOWN ON PLAN. THE DEVELOPER SHALL BE RESPONSIBLE FOR THE
RELOCATION OF ANY UTILITY WITHIN THE EXISTING AND/OR RIGHT OF
WAY REQUIRED BY THE DEVELOPMENT.
COVER SHEET
SITE PLAN
ENLARGEMENT PLAN
CONSTRUCTION DETAILS
CONSTRUCTION DETAILS
CONSTRUCTION DETAILS
CONSTRUCTION DETAILS
CONSTRUCTION DETAILS
CONSTRUCTION DETAILS
R
I V
E
R
S
I D
E
V
E
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
15% PLANS
RIVERWALK CONNECTOR
(RIVERWALK PHASE 2)
BRIAN MELI
10198189
COVER SHEET
G-001
00G-001.dwg
N/A
APPROVED BY THE CITY OF HOPEWELL
CONSTRUCTION MANAGER DATE
CITY ENGINEER DATE
Y L O
R S
T R
E E
T
N
V
E
N
U
E
S
T
A
O
U
N
D
O
L
O
A
D
V
A
R
I
A
B
L
W
I
D
W
R
/W
W
L
E
Y
R
R
R
R
RIVERWALK WITH TIMBER CANOPY
(CENTERED BETWEEN EXISTING PIERS)
- SEE SHEET L-901, 902
PHASE 2 OVERLOOK
- SEE SHEET L-904
PHASE 1 WESTERN OVERLOOK
BEGIN COVERED
RIVERWALK
241'-0"+/-
END COVERED
RIVERWALK
PHASE 2 PROPOSED RIVERWALK, 8'-8'' WIDE, TYP.
- SEE SHEET L-903
CONNECTION TO EXISING DOCK
(SHALL BE ADA COMPLIANT,
UNDER 5% SLOPE)
18'-0"+/-
18'-0"+/-
FUTURE PHASE
- NOT IN CONTRACT
PHASE 2 EXPANSION OF WESTERN OVERLOOK
- SEE SHEET L-905
SEE ENLARGEMENT PLAN,
SHEET L-102
CONCRETE PLAZA
- SEE PLAZA DETAILS IN SHEET L-102
EXISTING VAW WALKWAY
EBL PIER 17 WBL PIER 18
EBL PIER 18
WBL BENT 19
15'
(NOTE A)
15'
(NOTE A)
20'
(NOTE B)
15'
(NOTE A)
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
15% PLANS
RIVERWALK CONNECTOR
(RIVERWALK PHASE 2)
BRIAN MELI
10198189
PLAN
NORTH
TIMBER CONCRETE PLANTING
MATERIAL LEGEND
ASPHALT
SITE PLAN
1"=100'-0"
L-101
0 100' 200'
00L-101.dwg
GENERAL NOTE - THE OVERALL AERIAL IMAGERY IS APPROXIMATE. THE LOCATIONS OF THE BRIDGE PIERS AND BENTS ARE THE SURVEYED LOCATIONS.
NOTE A - THE MINIMUM ALLOWABLE LATERAL DISTANCE FROM THE NEAR FACE OF THE PIER FOOTING TO THE NEAR LIMIT OF THE RIVERWALK TRESTLE IS 15'.
NOTE B - THE MINIMUM ALLOWABLE LATERAL DISTANCE FROM THE CENTERLINE OF THE BENT CAP TO TO THE NEAR LIMIT OF THE RIVERWALK TRESTLE IS 20'.
cbennett Polygon cbennett Text Box This section of Riverwalk Completed fall 2023
+ 5.50 (P)
3.10 (P)
5.06 (P)
+ 4.96 (P)
5.30 (P)
5.23 (P) +
5.30 (P)
5.43 (E) +
5.16 (P)
PROPOSED CONCRETE PLAZA - SEE PLAZA DETAIL
(24" MAX. HEIGHT BETWEEN TOP OF SLAB AND GRADE)
PROPOSED CONCRETE PATH TO
MEET EXISTING TOP OF CURB
EVENLY AND SMOOTHLY
PROPOSED ASPHALT PATH
(SHALL BE ADA COMPLIANT,
UNDER 5% SLOPE)
PROPOSED CONCRETE PAD TO
MEET EXISTING TOP OF DOCK
EVENLY AND SMOOTHLY,
CONTRACTOR TO TURN DOWN
CONCRETE ON THE NORTH SIDE
FOR A DEPTH OF 2'
EXISTING PIPE
TO REMAIN
18'-0"+/-
PROPOSED TIMBER
RIVERWALK
PROPOSED CANOPY
PROPOSED RIVERWALK TO
MEET EXIST. VAW WALKWAY
(ELEV. 5.50) EVENLY AND
SMOOTHLY
EXIST. VAW WALKWAY
ALLOW FOR 16' O.C. MIN. SPAN BETWEEN
RIVERWALK PILES IN THIS LOCATION TO
ALLOW FOR FUTURE PIPE EXTENSION IF
NEEDED - SEE CONSTRUCTION DETAILS,
SHEET L-906, A
R
PROPOSED PLANTING BED
- TYPE A, SEE NOTE 1
R
FUTURE PHASE - NOT IN CONTRACT
PROPOSED TREES (7)
- TYPE A, SEE NOTE 1
PROPOSED TREES (2)
- TYPE B, SEE NOTE 1
PROPOSED PLANTING BED
- TYPE A, SEE NOTE 1
PROPOSED PLANTING BED
- TYPE B, SEE NOTE 1
FUTURE PIPE EXTENSION
- NOT IN CONTRACT
5.40 (P)
T
Y
P
R
R
8'-5
E
B
W
E
W
N
T
SEE SHEET L-101
NOTE A
SEE SHEET L-101
NOTE B
SEE SHEET L-101
NOTE A
SEE SHEET L-101
NOTE A
SEE NOTE 3SEE NOTE 2
M
X
M
A X
M A
X
M
X
R
R
M A
X
R
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
15% PLANS
RIVERWALK CONNECTOR
(RIVERWALK PHASE 2)
BRIAN MELI
10198189
TIMBER CONCRETE PLANTING TREE
PLAZA DETAILS
NOTE 1
1. TREES
TYPE A - SWEETBAY MAGNOLIA (MAGNOLIA VIRGINIANA)
TYPE B - RED MAPLE (ACER RUBRUM)
2. PLANTING BED
TYPE A - MIXTURE OF GROUNDCOVER (1290 SF)
TYPE B - MIXTURE OF GROUNDCOVER ( 85 SF)
MATERIAL LEGEND
NOTE 2
1. ELEVATION
- X.XX (E): EXISTING ELEVATION
- X.XX (P): PROPOSED ELEVATION
ASPHALT
PLAN
NORTH
ENLARGEMENT PLAN
00L-102.dwg
N/A
L-102
0 20' 40'
0 10' 20'
NOTE 3
- CONTRACTOR TO ENSURE NO POSTS ARE LOCATED
WITHIN THE 15' PIER FOOTING OFFSET.
8'-0" TYP.
8'-0" TYP. 8'-8"+/-
2'-6" 2'-6"
14'-4"
7'-9"
8"X8" ROOF RAFTER, TYP.
2"X2" WIRE MESH SCREEN, TYP.
2"X10" TOP CAP
EXISTING GRADE / WATER LEVEL
8" DIA. TIMBER PILE, TYP.2"X12" GIRDER, TYP.2"X8" FLOOR PLANK, TYP.
2"X10" JOIST, TYP.
2"X8" RAIL, TYP.
8"X8" POST,
TYP.
8"X8" BEAM, TYP.
4'-0" TYP.
ELEVATION
N.T.S
SECTION
N.T.S
2"X10" TOP CAP, TYP.
2"X8" RAIL, TYP.
2"X2" WIRE MESH SCREEN,
TYP.
8"X8" POST BEYOND, TYP.
2"X12" GIRDER
2"X10" JOIST, TYP.
2'-0" 2'-0"
GENERAL NOTES
1. DETAILS MAY BE USED FOR APPROXIMATELY 241 LINEAR FEET FOR THE PROPOSED RIVER
WALK COVERED BRIDGE AT THE SUBJECT PROJECT IN THE LOCATION SHOWN ON THE SITE
PLAN.
2. DETAILS ON THIS SHEET ARE TO ILLUSTRATE DESIGN INTENT ONLY, NOT FOR
CONSTRUCTION. ALL TIMBER, FASTENER CONNECTIONS AND STRUCTURAL DETAILS AND
SPECIFICATIONS SHALL BE PROVIDED AT A LATER PHASE OF DOCUMENTATION.
ILLUSTRATIVE RENDERING
ROOF BATTEN, TYP.
8"X8" ROOF JOIST, TYP.
8"X8" BEAM, TYP.
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
15% PLANS
RIVERWALK CONNECTOR
(RIVERWALK PHASE 2)
BRIAN MELI
10198189
L-901
CONSTRUCTION DETAILS
- BOARDWALK WITH TIMBER CANOPY
N.T.S
00L-901.dwg
4'-0"
10'-0"
8"X8" POST,
TYP.
4'-0" TYP.
NORTH ELEVATION
N.T.S
6'-0" 6'-0"
EXISTING GRADE /
WATER LEVEL
PROTECT
EXISTING VAW PIPE
PROPOSED COVERED RIVERWALK
4'-0"
EXISTING VAW WALKWAY TO REMAIN
OPENING CENTERED ON
EXIST. VAW WALKWAY
8'-0" TYP.
PROPOSED GATE (SEE NOTES)
NOTES
1. EXISTING DECKING AT
INTERSECTION OF COVERED
RIVERWALK AND VAW
BOARDWALK TO BE REPLACED
TO MATCH PROPOSED
RIVERWALK DECKING
2. EXISTING VAW BOARDWALK
RAILING TO BE REMOVED AS
NECESSARY TO ALLOW FOR
UNOBSTRUCTED ROUTE ALONG
PROPOSED RIVERWALK
3. PROPOSED LOCKED GATES TO
BE PROVIDED AT BOTH SIDES
OF VAW BOARDWALK AND
RIVERWALK INTERSECTIONS (4
TOTAL) TO PREVENT PUBLIC
ACCESS ONTO VAW
BOARDWALKS. GATES TO BE
INTEGRATED WITH THE
PROPOSED RIVERWALK
CANOPY. GATE CONSTRUCTION
SHALL CONSIST OF WOOD AND
MESH MATERIALS TO MATCH
PROPOSED CANOPY DESIGN.
10'-0"
241'-0"+/-
200'-4"+/-
OVERALL NORTH ELEVATION
N.T.S
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
15% PLANS
RIVERWALK CONNECTOR
(RIVERWALK PHASE 2)
BRIAN MELI
10198189
L-902
CONSTRUCTION DETAILS
- RIVERWALK WITH TIMBER CANOPY
8'-0" TYP. 8'-8"+/-
7'-9"
2"X10" TOP CAP
EXISTING GRADE / WATER LEVEL
8" DIA. TIMBER PILE, TYP.2"X12" GIRDER, TYP.2"X8" FLOOR PLANK, TYP.
2"X10" JOIST, TYP.
2"X8" RAIL, TYP.
4'-0" TYP.
TYPICAL ELEVATION
N.T.S
TYPICAL SECTION
N.T.S
2"X10" TOP CAP, TYP.
2"X8" RAIL, TYP.
2"X12" GIRDER
2"X10" JOIST, TYP.
2'-0" 2'-0"
EXISTING PHASE 1 RIVERWALK PHOTOS FOR REFERENCE (*PHASE 2 RIVERWALK TO MATCH)
4"X4" POST, TYP.
4'-0" TYP.
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
15% PLANS
RIVERWALK CONNECTOR
(RIVERWALK PHASE 2)
BRIAN MELI
10198189
L-903
CONSTRUCTION DETAILS
- RIVERWALK
2"X10" TOP CAP
2"X12" GIRDER,
TYP.
2"X8" FLOOR PLANK,
TYP.
2"X10" JOIST,
TYP.
2"X8" RAIL, TYP.
8" DIA. TIMBER PILE, TYP.
4'-4"+/-
2"X10" TOP CAP, TYP.
2"X8" RAIL, TYP.
2"X12" GIRDER
2"X10" JOIST, TYP.
2'-2"
8" DIA. TIMBER PILE, TYP.
8'-8"+/- 8'-8"+/-
8'-0", TYP.
2"X12" GIRDER, TYP.
2"X8" FLOOR PLANK, TYP.
2"X10" TOP CAP
8" DIA. TIMBER PILE, TYP.
2'-0"2'-2"
8'-0", TYP.
24'-0"
24'-0"
2"X10" JOIST, TYP.
2"X8" RAIL, TYP.
BENCH, TYP.
BY OTHERS
EXISTING GRADE
/ WATER LEVEL
EXISTING GRADE
/ WATER LEVEL
ELEVATION
N.T.S
SECTION
N.T.S
PLANVIEW
N.T.S
NOTES
1. DETAILS ON THIS SHEET ARE TO ILLUSTRATE DESIGN INTENT
ONLY, NOT FOR CONSTRUCTION. ALL TIMBER, FASTENER
CONNECTIONS AND STRUCTURAL DETAILS AND SPECIFICATIONS
SHALL BE PROVIDED AT A LATER PHASE OF DOCUMENTATION.
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
15% PLANS
RIVERWALK CONNECTOR
(RIVERWALK PHASE 2)
BRIAN MELI
10198189
L-904
CONSTRUCTION DETAILS
- PHASE 2 OVERLOOK
8" DIA. TIMBER PILE, TYP.
16'-0" - EXPANSION
2"X10" TOP CAP
2"X12" GIRDER,
TYP.
2"X8" FLOOR
PLANK, TYP.
2"X10" JOIST,
TYP.
2"X8" RAIL, TYP.
16'-0" - EXISTING OVERLOOK
ELEVATION
N.T.S
4'-4"+/-
EXISTING GRADE
/ WATER LEVEL
SECTION
N.T.S
2"X10" TOP CAP, TYP.
2"X8" RAIL, TYP.
2"X12" GIRDER
2"X10" JOIST, TYP.
2"X10" JOIST, TYP.
8'-8"+/- 4'-4"+/-
16'-0" - EXISTING OVERLOOK
SEE ROOF PLAN VIEW
4'-0", TYP.
8" DIA. TIMBER PILE, TYP.
EXISTING GRADE
/ WATER LEVEL
2"X4" ROOF SLATS
8"X6" RAFTER, TYP.
8"X8" POST, TYP.
PLANVIEW
N.T.S
2'-2"
2'-0" 2'-2"
2"X4" ROOF SLATS
8"X6" BRACKET, TYP.
8"X8" POST, TYP.
4'-8"
5'-10"
8"X6" RAFTER, TYP.
EXIST. BENCHNEW BENCH
BY OTHERS
RELOCATED BENCH
BY OTHERS
6"X8" POST,
TYP.
2"X12" GIRDER,
TYP.
8" DIA. TIMBER PILE,
TYP.
2"X8" FLOOR PLANK, TYP.
2"X10" TOP CAP, TYP.
ROOF DETAILS
N.T.S
2"X8" RAIL, TYP.
2"X4" ROOF SLATS
4'-0", TYP.
8"X8" POST, TYP.
8"X6" BRACKET, TYP.
8"X6" RAFTER, TYP.
8'-0", TYP.
16'-0" - EXPANSION
8"X8" ROOF BEAM, TYP.
8"X8" ROOF BEAM, TYP.
EXISTING
EXPANSION
27'-0"
1'-6"
EXIST. BENCH TO BE RELOCATED
BY OTHERS
NOTES
1. REMOVE EAST SIDE CAP AND RAILINGS OF THE EXISTING
OVERLOOK.
2. DETAILS ON THIS SHEET ARE TO ILLUSTRATE DESIGN INTENT
ONLY, NOT FOR CONSTRUCTION. ALL TIMBER, FASTENER
CONNECTIONS AND STRUCTURAL DETAILS AND SPECIFICATIONS
SHALL BE PROVIDED AT A LATER PHASE OF DOCUMENTATION.
3. EXISTING OVERLOOK DIMENSIONS TO BE FIELD VERIFIED PRIOR
TO CONSTRUCTION. DIMENSIONS SHOWN ARE APPROXIMATE
BASED ON PHASE 1 DRAWINGS.
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
15% PLANS
RIVERWALK CONNECTOR
(RIVERWALK PHASE 2)
BRIAN MELI
10198189
L-905
CONSTRUCTION DETAILS
- EXPANSION OF WESTERN OVERLOOK
CONCRETE SLAB
WITH TURN-DOWN
GRADE
(24" MAX BELOW TOP OF SLAB)
AGGREGATE
M
I N
COMPACTED
SUBGRADE
1/4" MAX. GAP BETWEEN
CONCRETE AND BOARDWALK
A
NOTE
1. DETAILS ON THIS SHEET ARE TO ILLUSTRATE DESIGN INTENT ONLY, NOT FOR
CONSTRUCTION. ALL TIMBER, FASTENER CONNECTIONS AND STRUCTURAL DETAILS
AND SPECIFICATIONS SHALL BE PROVIDED AT A LATER PHASE OF DOCUMENTATION.
4'-0" , TYP.
8'-0"8'-0"
2"X10" TOP CAP
2"X8" RAIL, TYP.
4"X4" POST, TYP.
8" DIA. TIMBER PILE, TYP.
EXISTING GRADE
FUTURE PIPE EXTENSION IF NEEDED
BOARDWALK AT TRAILHEAD PLAZA AND DRAINAGE PIPE CROSSING
N.T.S
1'-6"
16'-10"
7'-4"
3'-8"
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
15% PLANS
RIVERWALK CONNECTOR
(RIVERWALK PHASE 2)
BRIAN MELI
10198189
L-906
CONSTRUCTION DETAILS
| 00G-001-G-001 |
| G-001 |
| 00L-101-L-101 |
| L-101 |
| 00L-102-L-102 |
| L-102 |
| 00L-901-L-901 |
| L-901 |
| 00L-901-L-902 |
| L-902 |
| 00L-901-L-903 |
| L-903 |
| 00L-901-L-904 |
| L-904 |
| 00L-901-L-905 |
| L-905 |
| 00L-901-L-906 |
| L-906 |
File details come from the government source that posted it. Updated .