About this file

This solicitation notice is for a new construction project at Camp Perry Logistics Complex in Port Clinton, Ohio. The project has an estimated value between $5-10 million and has been set aside for small businesses with a NAICS code of 236220 and size standard of $39.5 million average annual revenue. Interested contractors must register in SAM and review plans and specifications through the federal contracting opportunities portal. The pre-bid conference will follow registration and base access requirements. Questions should be submitted using the template in the instructions to bidders. Bids are due October 31, 2022 and will be evaluated without discussions. Award will be made to the responsible bidder providing the best value in accordance with FAR procedures. The 179th Airlift Wing Contracting Office is the issuing office. Construction will include a new logistics complex to support the 200th Camp Perry Ohio Army National Guard.

View the file

Other files for this federal contract opportunity

Other files attached to Camp Perry Logistics Complex, newest first.
File Type Posted
Abstract REV01_Complex.pdf PDF
Abstract_Complex.pdf PDF
Sign in sheet_Complex.pdf PDF
W50S8R-22-B-0001 0008.pdf PDF
Request for Information (RFI) document_06.pdf PDF
Request for Information (RFI) document_05.pdf PDF
W50S8R-22-B-0001 0007.pdf PDF
W50S8R-22-B-0001 0006.pdf PDF
Request for Information (RFI) document_04.pdf PDF
Request for Information (RFI) document_03.pdf PDF
W50S8R-22-B-0001 0005.pdf PDF
W50S8R-22-B-0001 0004.pdf PDF
Request for Information (RFI) document_02.pdf PDF
W50S8R-22-B-0001 0003.pdf PDF
RFI 01_Red Horse Site Plan.pdf PDF
RFI 01_Geotechnical Report.pdf PDF
RFI 01_Environmental Report.pdf PDF
Request for Information (RFI) document_01.pdf PDF
W50S8R-22-B-0001 0002.pdf PDF
sign in sheet.pdf PDF
Pre-Bid Conference minutes_Complex.pdf PDF
Pre-Bid Conference-slides.pptx PPTX presentation
W50S8R-22-B-0001 0001.pdf PDF
Attachment 01-G_Drawings.pdf PDF
Exhibit A_Sealed Bid Checklist Reminders.pdf PDF
Attachment 01-I_Drawings.pdf PDF
Attachment 01-H_Drawings.pdf PDF
Attachment 01-D_Drawings.pdf PDF
Attachment 01-B_Drawings.pdf PDF
Attachment 03_Specifications Vol 02.pdf PDF
Attachment 02_Specifications Vol 01.pdf PDF
Attachment 01-F_Drawings.pdf PDF
Attachment 01-E_Drawings.pdf PDF
Attachment 01-A_Drawings.pdf PDF
Exhibit B_Checklist for Bid Bonds.pdf PDF
W50S8R-22-B-0001.pdf PDF
Show all 36

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A501

EXTERIOR WALL SECTIONS

BN

BN/CO

RKF

D W

G

N

A M

E

C

U

S E

R S

O

U A

P P

D A

T A

L O

C A

L P

R O

J E

C T

W I S

E W

O R

K D

I R

M

O T

T U

S E

P

W D

M S

A

D

W G

S

A V

E

D

A T

E

P

M

B

Y

O

U

L O

T

D

A T

E

P

M

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

APRIL 13 2022

507101745

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

P r o j e c t

N o

E

U B

C

P o r t

C l i n t o n

O

H

C a m p

P e r r y t h

R

E D

H

O R q u a d r o n

C

B

A

D

C

B

A

54321

1 W oo d A ve S ou th

Ise lin

, N J 0

-4

3.3

.34

| m ott ma c.c om

R E

D

H

O R o g i s t i c s

C o m p l e x

B-3 SUBMISSION - BID SET

BG

SCALE: 1-1/2" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

STANDING SEAM METAL ROOFING SYSTEM (SEE ROOF DETAILS TYP)

AutoCAD SHX Text

THERMAL SPACER (R-3)

AutoCAD SHX Text

R-11 BATT INSULATION BETWEEN ROOF PURLING

AutoCAD SHX Text

CONT. R-19 BATT INSULATION

AutoCAD SHX Text

ROOF PURLING

AutoCAD SHX Text

PREFINISHED MTL GUTTER

AutoCAD SHX Text

BUILDING GIRT

AutoCAD SHX Text

R-21 VINYL FACE BATT INSULATION

AutoCAD SHX Text

PREFINISHED MTL WALL PANEL

AutoCAD SHX Text

NOTE: ALL EXPOSED STRUCTURAL STEEL SHALL BE PAINTED SEE ROOM FINISH SCHEDULE

AutoCAD SHX Text

STRUCTURAL FRAME BEYOND

AutoCAD SHX Text

SNOW GUARD (SEE ROOF DETAILS TYP)

AutoCAD SHX Text

AutoCAD SHX Text A503

AutoCAD SHX Text A501

AutoCAD SHX Text

CONCRETE SLAB (SEE STRUCTURAL DWGS)

AutoCAD SHX Text

VAPOR BARRIER

AutoCAD SHX Text

6" COMPACTED FILL

AutoCAD SHX Text

COMPACTED BACKFILL

AutoCAD SHX Text

PREMOLDED FILLER

AutoCAD SHX Text

PREFINISHED MTL WALL PANEL

AutoCAD SHX Text

AutoCAD SHX Text A502

AutoCAD SHX Text A501

AutoCAD SHX Text

FIN GRADE (SEE CIVIL DWGS)

AutoCAD SHX Text

WALL LINER PANEL

AutoCAD SHX Text

SEE STRUCTURAL DWGS FOR FOUNDATION DETAILS

AutoCAD SHX Text

DRAIN TILE (SEE CIVIL DWGS)

AutoCAD SHX Text

3" THINK RIGID INSULATION @ PERIMETER

AutoCAD SHX Text

SEE STRUCTURAL DWGS FOR FOUNDATION DETAILS

AutoCAD SHX Text

3" THINK RIGID INSULATION @ PERIMETER

AutoCAD SHX Text

VINYL BASE OVER STUD WALL. (SEE WALL TYPE FOR DETAILS)

AutoCAD SHX Text

FIN FLOOR (SEE ROOM FIN SCHEDULE)

AutoCAD SHX Text

8" CMU (SEE STRUCTURAL DWGS FOR REINFORCEMENT)

AutoCAD SHX Text

CONCRETE SLAB (SEE STRUCTURAL DWGS)

AutoCAD SHX Text

BOND BEAM (SEE STRUCTURAL DWGS FOR DETAILS)

AutoCAD SHX Text

VAPOR BARRIER

AutoCAD SHX Text

6" COMPACTED FILL

AutoCAD SHX Text

COMPACTED BACKFILL

AutoCAD SHX Text

FIN GRADE (SEE CIVIL DWGS)

AutoCAD SHX Text

AutoCAD SHX Text A502

AutoCAD SHX Text A501

AutoCAD SHX Text

AutoCAD SHX Text A502

AutoCAD SHX Text A501

AutoCAD SHX Text

STEEL TRUSS SYSTEM (SEE STRUCTURAL DWGS)

AutoCAD SHX Text

STANDING SEAM METAL ROOFING SYSTEM (SEE ROOF DETAILS TYP)

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text

SELF-ADHERED MOISTURE/ AIR BARRIER

AutoCAD SHX Text

CONT. R-30 RIGID INSULATION

AutoCAD SHX Text

PREFINISHED MTL GUTTER

AutoCAD SHX Text

SNOW GUARD (SEE ROOF DETAILS TYP)

AutoCAD SHX Text .080" THK ALUM 1-1/2" GUTTER HANGER AT 30" O.C. STAGGERED FROM STRAP WRAP W/ 2" WIDE PREFINISHED ALUM COVER OVER HANGER

AutoCAD SHX Text

SELF-ADHERED MOISTURE/ AIR BARRIER

AutoCAD SHX Text 3/4" THK EXTERIOR GRADE FIRE RETARDANT TREATED PLYWOOD SHEATHING FASTENED W/ #10 SS SCREWS

AutoCAD SHX Text

METAL ROOF FACIA

AutoCAD SHX Text

METAL SOFFIT

AutoCAD SHX Text

22 GA PREFINISHED GALV ANGLE TRIM W/ HEMMED DRIP EDGE

AutoCAD SHX Text

INSULATED METAL PANEL

AutoCAD SHX Text

ROOF DECK

AutoCAD SHX Text

SELF-ADHERED MOISTURE/ AIR BARRIER

AutoCAD SHX Text

ROOF DECK

AutoCAD SHX Text

AutoCAD SHX Text A503

AutoCAD SHX Text A501

AutoCAD SHX Text CONT 16 GA 7/8" HAT CHANNEL FASTENED W/ 3/16" SS TAPCON FASTENERES AT 8" O.C. STAGGERED

AutoCAD SHX Text 9'-0"

AutoCAD SHX Text 9'-0"

AutoCAD SHX Text

ACOUSTICAL CEILING TILE SYSTEM

AutoCAD SHX Text

SEE STRUCTURAL DWG FOR FRAMING AND BENT PLATE DETAIL

AutoCAD SHX Text

FOAM SPRAY INSULATION

AutoCAD SHX Text

STANDING SEAM METAL ROOFING SYSTEM (SEE ROOF DETAILS TYP)

AutoCAD SHX Text

THERMAL SPACER (R-3)

AutoCAD SHX Text

R-11 BATT INSULATION BETWEEN ROOF PURLING

AutoCAD SHX Text

CONT. R-19 BATT INSULATION

AutoCAD SHX Text

BUILDING GIRT

AutoCAD SHX Text

R-21 VINYL FACE BATT INSULATION

AutoCAD SHX Text

PREFINISHED MTL WALL PANEL

AutoCAD SHX Text

NOTE: ALL EXPOSED STRUCTURAL STEEL SHALL BE PAINTED SEE ROOM FINISH SCHEDULE

AutoCAD SHX Text

STRUCTURAL FRAME BEYOND

AutoCAD SHX Text

OVERLAP LITE PANEL OVER WALL PANEL AND SET IN SEALANT

AutoCAD SHX Text

TRANSLUCENT LITE PANEL

AutoCAD SHX Text

INNER TRANSLUCENT LITE PANEL

AutoCAD SHX Text

STEEL GIRT

AutoCAD SHX Text

STEEL GIRT

AutoCAD SHX Text

PREFINISHED MTL CLOSURE W/ DRIP EDGE

AutoCAD SHX Text

JAMB CHANNEL BEYOND

AutoCAD SHX Text

PREFINISHED MTL WALL PANEL

AutoCAD SHX Text

SEE ELEVATION

AutoCAD SHX Text

SEE ELEVATION

AutoCAD SHX Text

AutoCAD SHX Text A503

AutoCAD SHX Text A501

AutoCAD SHX Text

FIN GRADE (SEE CIVIL DWGS)

AutoCAD SHX Text

CONCRETE SLAB (SEE STRUCTURAL DWGS)

AutoCAD SHX Text

PAINTED PRE-ENGINEERED STEEL STRUCTURE BEYOND

AutoCAD SHX Text

AutoCAD SHX Text A502

AutoCAD SHX Text A501

AutoCAD SHX Text

VAPOR BARRIER

AutoCAD SHX Text

6" COMPACTED FILL

AutoCAD SHX Text

COMPACTED BACKFILL

AutoCAD SHX Text

SEE STRUCTURAL DWGS FOR FOUNDATION DETAILS

AutoCAD SHX Text

3" THINK RIGID INSULATION @ PERIMETER

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

TYP. WALL SECTION

AutoCAD SHX Text

@ PRE-ENGINEERED BLDG

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text

AutoCAD SHX Text A301

AutoCAD SHX Text A501

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

TYP. WALL SECTION

AutoCAD SHX Text

@ CMU WALL

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text

AutoCAD SHX Text A301

AutoCAD SHX Text A501

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

TYP. WALL SEC. W/ TRANSLUCENT PANEL

AutoCAD SHX Text

@ PRE-ENGINEERED BLDG

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text

AutoCAD SHX Text A301

AutoCAD SHX Text A501

A502

EXTERIOR WALL SECTIONS

BN

BN/CO

RKF

D W

G

N

A M

E

C

U

S E

R S

O

U A

P P

D A

T A

L O

C A

L P

R O

J E

C T

W I S

E W

O R

K D

I R

M

O T

T U

S E

P

W D

M S

A

D

V

E

D

A T

E

O

U

O

T

D

A T

E

P

M

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

APRIL 13 2022

507101745

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

P r o j e c t

N o

E

U B

C

P o r t

C l i n t o n

O

H

C a m p e r r y

R u a d r o n

C

B

A

D

C

B

A

54321

1 W oo d A ve S ou th

Ise lin

, N J 0

-4

3.3

.34

| m ott ma c.c om

R E

D

H

O R g i s t i c s

C o m p l e x

B-3 SUBMISSION - BID SET

BG

SCALE: 1-1/2" = 1'-0"

SCALE: 3" = 1'-0"

10 10 2 4

SCALE: 1/2" = 1'-0"

AutoCAD SHX Text

STANDING SEAM METAL ROOFING SYSTEM (SEE ROOF DETAILS TYP)

AutoCAD SHX Text

THERMAL SPACER (R-3)

AutoCAD SHX Text

R-11 BATT INSULATION BETWEEN ROOF PURLING

AutoCAD SHX Text

CONT. R-19 BATT INSULATION

AutoCAD SHX Text

ROOF PURLING

AutoCAD SHX Text

PREFINISHED MTL GUTTER

AutoCAD SHX Text

SNOW GUARD (SEE ROOF DETAILS TYP)

AutoCAD SHX Text

AutoCAD SHX Text A503

AutoCAD SHX Text A502

AutoCAD SHX Text

SEE WALL SECTION 3/A501 AT BREAK LINE FOR OPTION NO.6

AutoCAD SHX Text

STANDING SEAM METAL ROOFING SYSTEM (SEE ROOF DETAILS TYP)

AutoCAD SHX Text

SELF-ADHERED MOISTURE/ AIR BARRIER

AutoCAD SHX Text

RIGID INSULATION

AutoCAD SHX Text

ROOF DECK

AutoCAD SHX Text

STELL TRUSS SYSTEM (SEE STRUCTURAL DWGS)

AutoCAD SHX Text

BUILDING GIRT

AutoCAD SHX Text

R-21 VINYL FACE BATT INSULATION

AutoCAD SHX Text

PREFINISHED MTL WALL PANEL

AutoCAD SHX Text

STRUCTURAL FRAME BEYOND

AutoCAD SHX Text

PREFINISHED FLASHING W/ HEMMED EDGES

AutoCAD SHX Text

AutoCAD SHX Text A503

AutoCAD SHX Text A502

AutoCAD SHX Text

PREFINISHED TRANSITION FLASHING

AutoCAD SHX Text

PREFINISHED FLASHING

AutoCAD SHX Text

EXTERIOR GRADE PLYWOOD SHEATHING

AutoCAD SHX Text

ACOUSTICAL CEILING TILE SYSTEM

AutoCAD SHX Text

VAPOR BARRIER

AutoCAD SHX Text

6" COMPACTED FILL

AutoCAD SHX Text

COMPACTED BACKFILL

AutoCAD SHX Text

ADMINISTRATION SUITE SIDE

AutoCAD SHX Text

VINYL BASE OVER STUD WALL (SEE WALL TYPE FOR DETAILS)

AutoCAD SHX Text

FIN FLOOR (SEE ROOM FIN SCHEDULE)

AutoCAD SHX Text

8" CMU (SEE STRUCTURAL DWGS FOR REINFORCEMENT)

AutoCAD SHX Text

CONCRETE SLAB (SEE STRUCTURAL DWGS)

AutoCAD SHX Text

BOND BEAM (SEE STRUCTURAL DWGS FOR DETAILS)

AutoCAD SHX Text

PRE-ENGINEERED STRUCTURE BEYOND

AutoCAD SHX Text

POLISHED/ SEALED CONCRETE (SEE ROOM FINISH SCHEDULE)

AutoCAD SHX Text

WAREHOUSE/VEHICLE MAINTENANCE SIDE

AutoCAD SHX Text

8" CMU. SEE STRUCTURAL DWGS FOR REINFORCEMENT

AutoCAD SHX Text

ADMIN SUITE

AutoCAD SHX Text

WAREHOUSE/VEHICLE MAINTENANCE SIDE

AutoCAD SHX Text

2" INSUL. METAL PANEL

AutoCAD SHX Text

PRE-ENGINEERED STL COLUMN

AutoCAD SHX Text

CORNER TRIM

AutoCAD SHX Text

1/8" RIVET @ 8" O.C

AutoCAD SHX Text

CONT. SEALANT TAPE (TYP)

AutoCAD SHX Text

1/4" PANCAKE FASTENER

AutoCAD SHX Text

CORNER TRIM

AutoCAD SHX Text

1/4" PANCAKE FASTENER

AutoCAD SHX Text

BUTYL SEALANT

AutoCAD SHX Text

1/8" RIVET @ HAT CHANNEL

AutoCAD SHX Text

EXPANDABLE FOAM

AutoCAD SHX Text

1/8" RIVET @ 8" O.C

AutoCAD SHX Text

MTL WALL PANEL

AutoCAD SHX Text

FIN GRADE (SEE CIVIL DWGS)

AutoCAD SHX Text

14 GA GALV. SUPPORT ANGLE

AutoCAD SHX Text

CONT. SEALANT (TYP)

AutoCAD SHX Text

BASE FLASHING

AutoCAD SHX Text

1/8" RIVET @ 12" O.C

AutoCAD SHX Text

ANGLE TRIM

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text

MTL WALL PANEL

AutoCAD SHX Text

FIN GRADE (SEE CIVIL DWGS)

AutoCAD SHX Text

14 GA GALV. SUPPORT ANGLE

AutoCAD SHX Text

CONT. SEALANT (TYP)

AutoCAD SHX Text

BASE FLASHING

AutoCAD SHX Text

1/8" RIVET @ 12" O.C

AutoCAD SHX Text

ANGLE TRIM

AutoCAD SHX Text

SELF-ADHERED MOISTURE/ AIR BARRIER

AutoCAD SHX Text

CONT. SELF-ADHERED MOISTURE/ AIR BARRIER

AutoCAD SHX Text

STL PURLIN

AutoCAD SHX Text

2" METAL PANEL

AutoCAD SHX Text

CORNER TRIM

AutoCAD SHX Text

BUTYL SEALANT

AutoCAD SHX Text

1/8" RIVET @ STL PURLIN

AutoCAD SHX Text

1/8" RIVET

AutoCAD SHX Text

1/4" PANCAKE FASTENER

AutoCAD SHX Text

CONT. SEALANT TAPE (TYP)

AutoCAD SHX Text

EXPANDABLE FOAM

AutoCAD SHX Text

CORNER TRIM

AutoCAD SHX Text

PRE-ENGINEERED STL COLUMN

AutoCAD SHX Text

EXTERIOR

AutoCAD SHX Text

WAREHOUSE/VEHICLE MAINTENANCE SIDE

AutoCAD SHX Text

PREFINISHED STEP FLASHING

AutoCAD SHX Text

PREFINISHED METAL WALL PANEL

AutoCAD SHX Text

TRANSLUCENT WALL PANEL (OPTION NO.6)

AutoCAD SHX Text

OUTLINE OF ADMIN SUITE BUILDING

AutoCAD SHX Text

AutoCAD SHX Text A503

AutoCAD SHX Text A301

AutoCAD SHX Text

REFER TO ROOF TRANSITION DETAIL 7/A502/A503 FOR EXPANSION JOINT

AutoCAD SHX Text

STAINLESS STEEL DRAWBAND

AutoCAD SHX Text

SELF-ADHERED MOISTURE/ AIR BARRIER

AutoCAD SHX Text

METAL WALL PANEL

AutoCAD SHX Text

CMU

AutoCAD SHX Text

SEALANT

AutoCAD SHX Text

SEALANT

AutoCAD SHX Text

SEE WALL TYPES FOR DETAILS

AutoCAD SHX Text

SELF-ADHERED MOISTURE/ AIR BARRIER FLASHING STRIP

AutoCAD SHX Text

BATT INSULATION

AutoCAD SHX Text

CLOSED CELL FIRE RETARDANT SPRAY FOAM INSULATION

AutoCAD SHX Text 2-PIECE 22 GA PREFINISHED GALVALUME COVER PLATE SET IN SEALANT AND RIVETED TO PANEL AT 3" O.C. (RIVET TO MATCH PANEL COLOR)

AutoCAD SHX Text

PIPE

AutoCAD SHX Text

SELF-ADHERED MOISTURE/ AIR BARRIER

AutoCAD SHX Text

CMU

AutoCAD SHX Text

SEE FLOOR PLAN FOR WALL TYPE

AutoCAD SHX Text

INSULATED WALL PANEL

AutoCAD SHX Text

CONT 16 GA - 7/8" HAT CHANNEL

AutoCAD SHX Text

SEE STRUCTURAL DWGS FOR CMU REINFORCEMENT

AutoCAD SHX Text

RUBBER CONTROL JOINT GASKET

AutoCAD SHX Text

POLYURETHANE SEALANT

AutoCAD SHX Text

POLYURETHANE SEALANT

AutoCAD SHX Text

ZINC CONTROL JOINT

AutoCAD SHX Text

LATEX SEALANT

AutoCAD SHX Text

CONTROL JOINT

AutoCAD SHX Text

NOTE: SEE BUILDING ELEVATIONS ON SHEET A201, A202 FOR CONTROL JOINT LOCATIONS

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

WALL SECTION

AutoCAD SHX Text

@ BLDG TRANSITION

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text

AutoCAD SHX Text A301

AutoCAD SHX Text A502

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

WALL DETAIL

AutoCAD SHX Text

@ BLDG TRANSITION

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A101

AutoCAD SHX Text A502

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

ENLARGED BASE DETAIL

AutoCAD SHX Text

@ PRE-ENG BLDG

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A101

AutoCAD SHX Text A502

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

ENLARGED BASE DETAIL

AutoCAD SHX Text

@ CMU WALL

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A101

AutoCAD SHX Text A502

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

TYP. CORNER DETAIL

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A101

AutoCAD SHX Text A502

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

ENLARGED ELEVATION @ ROOF TRANSITION

AutoCAD SHX Text 1/2"

AutoCAD SHX Text

AutoCAD SHX Text A201

AutoCAD SHX Text A502

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

PIPE PENETRATION DETAIL @ METAL WALL PANEL

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A101

AutoCAD SHX Text A502

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

CMU BEARING CONTROL JOINT PLAN DETAIL

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A101

A502

A503

ROOF DETAILS

BN

BN/CO

RKF

D W

G

N

A M

E

C

U

S E

R S

O

U A

P P

D A

T A

L O

C A

L P

R O

J E

C T

W I S

E W

O R

K D

I R

M

O T

T U

S E

P

W D

M S

A

D

V

E

D

A T

E

O

U

O

T

D

A T

E

P

M

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

APRIL 13 2022

507101745

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

P r o j e c t

N o

E

U B

C

P o r t

C l i n t o n

O

H

C a m p

P e r r y

R u a d r o n

C

B

A

D

C

B

A

54321

1 W oo d A ve S ou th

Ise lin

, N J 0

-4

3.3

.34

| m ott ma c.c om

R E

D

H

O R g i s t i c s

C o m p l e x

B-3 SUBMISSION - BID SET

BG

SCALE: 3" = 1'-0"

10 1

SCALE: 1-1/2" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PREFINISHED ALUM DRIP EDGE

AutoCAD SHX Text

PREFINISHED ALUM FACIA

AutoCAD SHX Text

PREFINISHED ALUM SOFFIT

AutoCAD SHX Text

SEE STRUCTURAL DWGS FOR POST DETAILS

AutoCAD SHX Text

AutoCAD SHX Text A503

AutoCAD SHX Text A503

AutoCAD SHX Text

PREFINISHED MTL GUTTER

AutoCAD SHX Text

PREFINISHED MTL RIDGE FLASHING (SEE RIDGE DETAIL 3/A503/A502)

AutoCAD SHX Text

AutoCAD SHX Text A503

AutoCAD SHX Text A503

AutoCAD SHX Text

SIM

AutoCAD SHX Text

METAL DECKING

AutoCAD SHX Text STRUCTURAL STANDING SEAM METAL ROOFING SYSTEM SANDWICH PANEL W/ 6" THK RIGID INSULATION (SEE ROOFING DETAILS)

AutoCAD SHX Text

SIM

AutoCAD SHX Text

PAINTED STEEL POST BEYOND, SEE STRUCTURAL DWGS

AutoCAD SHX Text

SEE STRUCTURAL DWGS FOR TUBE DETAIL

AutoCAD SHX Text

AutoCAD SHX Text A503

AutoCAD SHX Text A503

AutoCAD SHX Text

SEE STRUCTURAL DWGS FOR TUBES AND PLATES DETAILS

AutoCAD SHX Text

SEE STRUCTURAL DWGS FOR TUBE AND CONNECTION DETAILS

AutoCAD SHX Text

WOOD BLOCKING

AutoCAD SHX Text

METAL DECKING

AutoCAD SHX Text

METAL DECK CLOSURE

AutoCAD SHX Text

PREFINISHED MTL PANEL END CAP

AutoCAD SHX Text

PREFINISHED MTL RIDGE FLASHING

AutoCAD SHX Text

2" THK SPRAY FOAM INSULATION

AutoCAD SHX Text

PANEL CLIP

AutoCAD SHX Text

CONT SEALANT TAPE

AutoCAD SHX Text

PREFINISHED MTL PANEL CLOSURE

AutoCAD SHX Text

CONT SEALANT TAPE

AutoCAD SHX Text STRUCTURAL STANDING SEAM METAL ROOFING SYSTEM SANDWICH PANEL W/ 6" THK RIGID INSULATION

AutoCAD SHX Text

DOUBLE PITCHED TOP CHORD BEARING TRUSS. SEE STRUCTURAL DWG FOR DETAILS

AutoCAD SHX Text 3"

AutoCAD SHX Text 3"

AutoCAD SHX Text

STL ROOF PURLIN

AutoCAD SHX Text

METAL CLOSURE

AutoCAD SHX Text

PANEL CLIP

AutoCAD SHX Text

CONT SEALANT TAPE

AutoCAD SHX Text

PREFINISHED MTL PANEL CLOSURE

AutoCAD SHX Text

STRUCTURAL STANDING SEAM METAL ROOFING SYSTEM W/ BATT INSULATION

AutoCAD SHX Text

BATT INSULATION

AutoCAD SHX Text

PREFINISHED MTL RIDGE FLASHING

AutoCAD SHX Text

PREFINISHED MTL PANEL END CAP

AutoCAD SHX Text

PRE-ENG. BLDG GIRT

AutoCAD SHX Text

PREFINISHED MTL WALL PANEL

AutoCAD SHX Text

PREFINISHED ALUM FLASHING W/ HEMMED EDGES MIN SLOPE 1/4"/FT

AutoCAD SHX Text

SLOPE

AutoCAD SHX Text

PREFINISHED TRANSITION FLASHING

AutoCAD SHX Text

R-21 BATT INSULATION

AutoCAD SHX Text

RAKE SUPPORT ANGLE

AutoCAD SHX Text

CONT. SELF-ADHERED MOISTURE/ AIR BARRIER

AutoCAD SHX Text

PANEL CLIP

AutoCAD SHX Text

ROOF DECK

AutoCAD SHX Text

8" CMU

AutoCAD SHX Text 1"

AutoCAD SHX Text 1"

AutoCAD SHX Text

3/4" EXTERIOR GRADE PLYWOOD SHEATHING

AutoCAD SHX Text

PREFINISHED FLASHING

AutoCAD SHX Text

MTE PLATE OVER MORTAR BED. SEE STRUCTURAL DWGS FOR DETAIL

AutoCAD SHX Text

SS SLIDING HOOK CLIP AT 4'-0" O.C. MAX

AutoCAD SHX Text

22 GA PREFINISHED GALVALUME STRUCTURAL STANDING SEAM ROOFING PANEL

AutoCAD SHX Text

KEYHOLE RIB CLOSURE

AutoCAD SHX Text 1" x 1" CONT DRIP ANGLE

AutoCAD SHX Text

22 GA PREFINISHED GALVALUME ALUM TRIM WITH 3/4" OPEN HEM

AutoCAD SHX Text 4" HIGH 16 GA COLD ROLLED GALVANIZED STEEL Z-GIRT AT 4'-0" O.C. FASTENED TO METAL DECK W/ 1/4" DIA SS TEK SCREWS AT 12" O.C.

AutoCAD SHX Text 2 LAYERS OF 2" THK EXTRUDED POLYSTYRENE INSULATION LOOSE LAID W/ TIGHT FIT BETWEEN Z-GIRTS (R-20)

AutoCAD SHX Text

EXTRUDED ALUM SNOW GUARD (SEE SNOW GUARD DETAIL)

AutoCAD SHX Text 1 LAYERS OF 2" THK CONTINUOUS EXTRUDED POLYSTYRENE INSULATION LOOSE LAID OVER Z-GIRTS (R-10)

AutoCAD SHX Text 22 GA GALVANIZED STEEL BEARING PLATE FASTENED TO WALL PANEL W/ #10 SS SCREWS AT 12" O.C.

AutoCAD SHX Text

SELF ADHERED SBS MODIFIED BITUMEN AIR BARRIER/ VAPOR RETARDER

AutoCAD SHX Text

SELF ADHERED SBS MODIFIED BITUMEN AIR BARRIER/ VAPOR RETARDER

AutoCAD SHX Text 3/4" THK EXTERIOR GRADE FIRE RETARDANT TREATED PLYWOOD SHEATHING FASTENED W/ #10 SS SCREWS

AutoCAD SHX Text PREFINISHED GALVALUME ANGLE TRIM W/ HEMMED EDGE RIVETED TO PANEL AT 12" O.C. (RIVET TO MATCH PANEL COLOR)

AutoCAD SHX Text 22 GA PREFINISHED GALVALUME FLUSH-SEAM METAL WALL PANELS W/ CONCEALED FASTENERS (FASTEN AT 6" O.C.)

AutoCAD SHX Text NOTE: SEE 4/A105/A503 FOR TYPICAL SEE 4/A105/A503 FOR TYPICAL GUTTER NOTES AND DIMENSIONS.

AutoCAD SHX Text 22 GA PREFINISHED GALVALUME FLUSH-SEAM PERFORATED METAL WALL PANELS W/ CONCEALED FASTENERS (FASTEN AT 6" O.C.)

AutoCAD SHX Text

SELF-ADHERED MOISTURE/ AIR BARRIER

AutoCAD SHX Text

SEE STRUCTURAL DWGS FOR TRUSS SYSTEM, ROOF DECK AND SOFFIT FRAMING

AutoCAD SHX Text 3/4" THK EXTERIOR GRADE FIRE RETARDANT TREATED PLYWOOD SHEATHING FASTENED W/ #10 SS SCREWS

AutoCAD SHX Text

SEE STRUCTURAL DWG FOR BENT PLATE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PREFINISHED MTL WALL PANEL

AutoCAD SHX Text

STL WALL PURLIN

AutoCAD SHX Text

BATT INSULATION

AutoCAD SHX Text .080" THK ALUM x 1-1/2" GUTTER STRAPS AT 30" O.C.

AutoCAD SHX Text .080" THK ALUM x 1-1/2" GUTTER HANGER AT 30" O.C. STAGGERED FROM STRAP WRAP W/ 2" WIDE PREFINISHED ALUM COVER OVER HANGER

AutoCAD SHX Text

22 GA PREFINISHED GALVALUME GUTTER WITH 6" WIDE OUTSIDE COVER PLATES

AutoCAD SHX Text 1" x 1" CONT DRIP ANGLE

AutoCAD SHX Text 22 GA GALVANIZED STEEL BEARING PLATE FASTENED TO WALL PANEL W/ #10 SS SCREWS AT 12" O.C.

AutoCAD SHX Text

SELF ADHERED SBS MODIFIED BITUMEN AIR BARRIER/ VAPOR RETARDER

AutoCAD SHX Text

KEYHOLE RIB CLOSURE

AutoCAD SHX Text

CONT SEALANT TAPE

AutoCAD SHX Text

STL ROOF PURLIN

AutoCAD SHX Text

STL BENT PLATE CLOSURE

AutoCAD SHX Text

BATT INSULATION

AutoCAD SHX Text

22 GA PREFINISHED GALVALUME TRIM WITH 3/4" OPEN HEM

AutoCAD SHX Text

SS SLIDING HOOK CLIP AT 4'-0" O.C. MAX

AutoCAD SHX Text

22 GA PREFINISHED GALVALUME STRUCTURAL STANDING SEAM ROOFING PANEL

AutoCAD SHX Text

EXTRUDED ALUM SNOW GUARD (SEE SNOW GUARD DETAIL)

AutoCAD SHX Text

SS SLIDING HOOK CLIP AT 4'-0" O.C. MAX

AutoCAD SHX Text

22 GA PREFINISHED GALVALUME STRUCTURAL STANDING SEAM ROOFING PANEL

AutoCAD SHX Text

GABLE CLIP AT 2'-0" O.C. MAX

AutoCAD SHX Text

GABLE FLASHING GALV STL CONT CLEAT

AutoCAD SHX Text

PAINTED FASTENERS AT 24" O.C.

AutoCAD SHX Text

6" X 6" 22 GA GALVANIZED STEEL PUNCHED BEARING PLATE

AutoCAD SHX Text

PREFINISHED METAL WALL PANEL W/ CONCEALED FASTENER

AutoCAD SHX Text

STL ROOF PURLIN W/ BATT INSULATION

AutoCAD SHX Text

PRE ENGINEERED BUILDING GIRT

AutoCAD SHX Text

PRE ENGINEERED STRUCTURE BEYOND

AutoCAD SHX Text

PREFINISHED ALUM DRIP EDGE

AutoCAD SHX Text

PREFINISHED ALUM FACIA

AutoCAD SHX Text

PREFINISHED ALUM SOFFIT

AutoCAD SHX Text

PAINTED STEEL POST, SEE STRUCTURAL DWGS

AutoCAD SHX Text 4" HIGH 16 GA COLD ROLLED GALVANIZED STEEL Z-GIRT AT 4'-0" O.C. FASTENED THROUGH 2"X WOOD BLOCKING

AutoCAD SHX Text 22 GA PREFINISHED GALVALUME GABLE FLASHING WITH GALV STL CONT CLEAT (W/ 4" SEALED JOINTS)

AutoCAD SHX Text

CONT 6"W 22 GA GALVANIZED STEEL BEARING PLATE

AutoCAD SHX Text

GABLE CLIP AT 2'-0" O.C. MAX

AutoCAD SHX Text

CANOPY RIDGE BEYOND

AutoCAD SHX Text

PAINTED FASTENERS AT 24" O.C.

AutoCAD SHX Text

TUBES AND PLATES BEYOND, SEE STRUCTURAL DWG

AutoCAD SHX Text

METAL STUD FRAMING TO SOFFIT FASCIA AND SOFFIT @ 12" OC

AutoCAD SHX Text

METAL STUD FRAMING TO SOFFIT FASCIA AND SOFFIT @ 12" OC

AutoCAD SHX Text

SEE STRUCTURAL DWGS FOR TUBE & BEARING DETAILS

AutoCAD SHX Text 4" HIGH 16 GA COLD ROLLED GALVANIZED STEEL Z-GIRT AT 4'-0" O.C. FASTENED THROUGH 2"X WOOD BLOCKING

AutoCAD SHX Text

PREFINISHED MTL VALLEY FLASHING W/ 4" SEALED LAP JOINTS

AutoCAD SHX Text

SELF-ADHERED MOISTURE/ AIR BARRIER

AutoCAD SHX Text

STANDING SEAM ROOF SYSTEM (TYP)

AutoCAD SHX Text

CONT TAPE SEALANT

AutoCAD SHX Text

PANEL CLOSURE

AutoCAD SHX Text

STANDING SEAM ROOF SYSTEM (TYP)

AutoCAD SHX Text

SEE STRUCTURAL DWGS FOR METAL DECK DETAILS

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

CANOPY SECTION

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text

AutoCAD SHX Text A301

AutoCAD SHX Text A503

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

TYP. RIDGE @ ADMIN. SUITE

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A105

AutoCAD SHX Text A503

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

TYP. EAVE @ ADMIN. SUITE

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A105

AutoCAD SHX Text A503

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

TYP. RIDGE @ PRE-ENG. BLDG

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A105

AutoCAD SHX Text A503

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

TYP. EAVE @ PRE-ENG. BLDG

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A105

AutoCAD SHX Text A503

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

TYP. RAKE @ PRE-ENG. BLDG

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A105

AutoCAD SHX Text A503

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

EXPANSION JOINT DETAIL

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A105

AutoCAD SHX Text A503

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

CANOPY TRANSITION DETAIL

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A105

AutoCAD SHX Text A503

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

CANOPY RAKE

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text

AutoCAD SHX Text A301

A503

A504

ROOF DETAILS

BN

BN/CO

RKF

D W

G

N

A M

E

C

U

S E

R S

O

U A

P P

D A

T A

L O

C A

L P

R O

J E

C T

W I S

E W

O R

K D

I R

M

O T

T U

S E

P

W D

M S

A

D

V

E

D

A T

E

O

U

O

T

D

A T

E

P

M

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

APRIL 13 2022

507101745

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

P r o j e c t

N o

E

U B

C

P o r t

C l i n t o n

O

H

C a m p

P e r r y

R u a d r o n

C

B

A

D

C

B

A

54321

1 W oo d A ve S ou th

Ise lin

, N J 0

-4

3.3

.34

| m ott ma c.c om

R E

D

H

O R g i s t i c s

C o m p l e x

B-3 SUBMISSION - BID SET

BG

SCALE: 3" = 1'-0"

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

DETAIL AT EXHAUST FAN HINGED CURB

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A105

AutoCAD SHX Text A504

AutoCAD SHX Text INSTALL EXHAUST FAN/ PENTHOUSE LOUVER/ GOOSENECK ON ROOF CURB (GPENTHOUSE LOUVER SHALL BE SAME COLOR AS ROOF)

AutoCAD SHX Text

GASKETED #12 SCREWS AT 12" O.C. (MIN 3 PER SIDE)

AutoCAD SHX Text

SEALANT TAPE

AutoCAD SHX Text INSULATED 18 GA GALVANIZED STEEL ROOF CURB FASTEN AT 12" O.C. W/ TEK SCREWS (MIN 3 PER SIDE)

AutoCAD SHX Text

SELF ADHERED SBS MODIFIED BITUMEN AIR BARRIER/ VAPOR RETARDER FLASHING

AutoCAD SHX Text

NOTE: SEE STRUCT DWGS FOR SEE STRUCT DWGS FOR CURB SUPPORT

AutoCAD SHX Text

22 GA PREFINISHED GALVALUME COUNTERFLASHING W/ DRIP EDGE

AutoCAD SHX Text 22 GA PREFINISHED GALVALUME SIDE FLASHING W/ 2" VERTICAL LEG TO FIT ADJACENT PANEL RIB

AutoCAD SHX Text

PANEL RIB CUT FROM PANEL

AutoCAD SHX Text SET SEALANT BETWEEN ADJACENT PANEL AND SIDE FLASHING VERTICAL LEG AND INSTALL CUT PANEL RIB OVER SET IN SEALANT AND RIVET AT 4" O.C.

AutoCAD SHX Text

ADJACENT STANDING SEAM ROOFING PANEL

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

EXHAUST FAN/PENTHOUSE CURB DETAIL

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A105

AutoCAD SHX Text A504

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

FLUE DETAIL (TYP)

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A105

AutoCAD SHX Text A504

AutoCAD SHX Text INSTALL EXHAUST FAN/ PENTHOUSE LOUVER/ GOOSENECK ON ROOF CURB (PENTHOUSE LOUVER SHALL BE SAME COLOR AS ROOF)

AutoCAD SHX Text

GASKETED #12 SCREWS AT 12" O.C. (MIN 3 PER SIDE)

AutoCAD SHX Text

SEALANT TAPE

AutoCAD SHX Text

SS SLIDING HOOK CLIP

AutoCAD SHX Text

STANDING SEAM ROOFING PANEL

AutoCAD SHX Text

CLOSURE WITH FOAM INSERT

AutoCAD SHX Text

ON BACK OF CLOSURE APPLY A CONT BEAD OF SEALANT TO BOTTOM AND SIDES

AutoCAD SHX Text

PAN END FULL WIDTH PANELS IN FRONT OF CURB

AutoCAD SHX Text 22 GA PREFINISHED GALVALUME APRON FLASHING FASTENED INTO CLOSURE W/ GASKETED FASTENERS (FORM 1" TABS ON ENDS OF APRON)

AutoCAD SHX Text

SEALANT TAPE

AutoCAD SHX Text INSULATED 18 GA GALVANIZED STEEL ROOF CURB FASTEN AT 12" O.C. W/ TEK SCREWS (MIN 3 PER SIDE)

AutoCAD SHX Text

SELF ADHERED SBS MODIFIED BITUMEN AIR BARRIER/ VAPOR RETARDER FLASHING

AutoCAD SHX Text

NOTE: SEE STRUCT DWGS FOR SEE STRUCT DWGS FOR CURB SUPPORT

AutoCAD SHX Text

22 GA PREFINISHED GALVALUME COUNTERFLASHING W/ DRIP EDGE

AutoCAD SHX Text

.040" MILL ALUM CURB BACK PAN W/ CRICKET AND 6" MIN WELDED CORNERS

AutoCAD SHX Text

22 GA PREFINISHED GALVALUME COUNTERFLASHING

AutoCAD SHX Text RIVET PANELS TO CLEAT AT 3" O.C. W/ 1" WIDE TAPE SEALANT BETWEEN (SEAL 2" ENDS OF STIFFENING BEADS W/ SEALANT)

AutoCAD SHX Text

KEYHOLE RIB CLOSURE

AutoCAD SHX Text

STAINLESS STEEL DRAW BAND OVER FLUE

AutoCAD SHX Text

STANDING SEAM END CAP. RIVET TO STORM COLLAR BASE AND PANEL RIB W/ SEALANT

AutoCAD SHX Text

KEYHOLE CLOSURE

AutoCAD SHX Text

CLEAT FLASHING W/ HEM

AutoCAD SHX Text

CUT RIB FROM END AND FOLD FLUSH

AutoCAD SHX Text

CUT SLIT IN BASE

AutoCAD SHX Text

METAL STORM COLLAR TO MATCH ROOF. EXTEND TO COVER RIVETS AND SEALANT

AutoCAD SHX Text

RIVET PANEL TO CLEAT AT 3" O.C W/ 1" TAPE SEALANT AND PLUG PENCIL RIBS W/ CAULK

AutoCAD SHX Text

OFFSET CLEAT. RIVET TO BASE AT 3" OC W/ 1" TAPE SEALANT

AutoCAD SHX Text

KEYHOLE CLOSURE

AutoCAD SHX Text

1" THERMAL JOINT

AutoCAD SHX Text

METAL BASE. FINISH TO MATCH ROOF. EXTEND SIDES TO NEXT PANEL SEAM

AutoCAD SHX Text A. WIRE ROPE: 6X19 CLASS, 1/2" PREFORMED SS WIRE WIRE ROPE: 6X19 CLASS, 1/2" PREFORMED SS WIREROPE I.W.R.C. - TYPE 302/304 B. THIMBLES: HEAVY DUTY SS THIMBLES - EY 18-16 THIMBLES: HEAVY DUTY SS THIMBLES - EY 18-16 TYPE 302/304 C. CLIPS: MALLEABLE WIRE ROPE CLIPS, CP2-16P (MIN 4 CLIPS: MALLEABLE WIRE ROPE CLIPS, CP2-16P (MIN 4 PER CABLE END)

AutoCAD SHX Text

WIRE ROPE ASSEMBLY SHALL CONSIST OF THE FOLLOWING

AutoCAD SHX Text 1.

AutoCAD SHX Text

%%UNOTES:

AutoCAD SHX Text

1/4"/1FT

AutoCAD SHX Text

GIRT (TYP.)

AutoCAD SHX Text

3/4" SS EYEBOLT W/ 1 1/2"I.D. EYE-BOLT AND WELD TO CHANNEL

AutoCAD SHX Text

WIRE ROPE ASSEMBLY (SEE NOTE BELOW)

AutoCAD SHX Text

C6 GAL. CONT.

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

NTS

AutoCAD SHX Text

CANOPY AT SECIONAL DOOR

AutoCAD SHX Text

AutoCAD SHX Text A105

AutoCAD SHX Text A504

EXTERIOR WALL - REFER TO WALL DETAILS FOR ASSEMBLY

A601

ROOM FINISH SCHEDULE

AND DETAILS

BN

BN

RKF

D W

G

N

A M

E

C

U

S E

R S

O

U A

P P

D A

T A

L O

C A

L P

R O

J E

C T

W I S

E W

O R

K D

I R

M

O T

T U

S E

P

W D

M S

A

D

V

E

D

A T

E

O

U

O

T

D

A T

E

P

M

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

APRIL 13 2022

507101745

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

P r o j e c t

N o

E

U B

C

P o r t

C l i n t o n

O

H

C a m p e r r y

R u a d r o n

C

B

A

D

C

B

A

54321

1 W oo d A ve S ou th

Ise lin

, N J 0

-4

3.3

.34

| m ott ma c.c om

R E

D

H

O R g i s t i c s

C o m p l e x

B-3 SUBMISSION - BID SET

BG

SCALE: 3" = 1'-0"

10 84

SCALE: 1/4" = 1'-0"

0 2

AutoCAD SHX Text

12 GA HANGER WIRE

AutoCAD SHX Text 12 GA HANGER WIRE ANCHORED TO STRUCTURE ABOVE AND HUNG VERTICALLY A MAX OF 8" FROM THE PERIMETER

AutoCAD SHX Text

MAIN TEE SPLICE COUPLING (OCCURS AT RANDOM)

AutoCAD SHX Text "A"

AutoCAD SHX Text "A"

AutoCAD SHX Text

3/4" FLEX CONDUIT 1819 6'-0" LONG MAX

AutoCAD SHX Text

CROSS TEE 1 1/2" HIGH, @ 2'-0" O.C.

AutoCAD SHX Text

MAIN TEE, 24" O.C. MAX., SHAPE & DESIGN AS APPROVED

AutoCAD SHX Text

S-HOOK TO TAB OR THROUGH FIXTURE BODY (4) PER FIXTURE

AutoCAD SHX Text

FIXTURE VARIES W/ MANUFACTURER

AutoCAD SHX Text SIDE MOUNTING LEVELING LUG BY FIXTURE MANUFACTURER INSTALLATION BY CONTRACTOR AS PART OF FIXTURE (2 PER SIDE)

AutoCAD SHX Text

SECTION "A-A"

AutoCAD SHX Text

DETAIL AT WALL

AutoCAD SHX Text

NOTES

AutoCAD SHX Text

DETAIL AT WALL

AutoCAD SHX Text

7/8" METAL FURRING CHANNEL

AutoCAD SHX Text

7/8" HAT SHAPED METAL FURRING CHANNEL

AutoCAD SHX Text

1/4" DIA. GALVANIZED STEEL ROD NOT TO EXCEED 4'-0" O.C.

AutoCAD SHX Text

GAT CLIP 4B1.5L CATALOG #16.59.SM (OR APPROVED EQUAL)

AutoCAD SHX Text

1 1/2" 16 GA STEEL SUSPENSION CHANNEL .475# APPROXIMATELY 4'-0" O.C.

AutoCAD SHX Text FOR DESIGN AND INSTALLATION OF HANGERS AND THEIR TIP AND BOTTOM CONNECTIONS, ABOVE ASTM STANDARDS SHALL BE REVISED AS FOLLOWS:

AutoCAD SHX Text ASTM C636-STANDARD PRACTICE FOR INSTALLATION OF MTL CEILING SUSPENSION SYSTEM FOR ACT AND LAY-IN PANELS

AutoCAD SHX Text THE CONTRACTOR SHALL BE REQUIRED TO SUBMIT CATALOG CUTS, SAMPLES LAYOUT DWG. AND DETAILS OF ALL COMPONENTS OF THE CLG. SUPPORT SYSTEM FOR APPROVAL PRIOR TO THE START OF ANY WORK IN THE FIELD.

AutoCAD SHX Text

ASTM C635-STANDARD SPEC. FOR MTL SUSPENSION SYSTEM FOR ACT AND LAY-IN PANELS

AutoCAD SHX Text THE FOLLOWING STANDARDS SHALL BE USED FOR DESIGN AND INSTALLATION OF ALL BLDG. COMPONENTS EXCEPT HANGERS AND THEIR TOP AND BOTTOM CONNECTIONS:

AutoCAD SHX Text 2.

AutoCAD SHX Text 1.

AutoCAD SHX Text

TILE OPENING

AutoCAD SHX Text

FROM J. BOX

AutoCAD SHX Text THE TOTAL WEIGHT OF A LIGHT FIXTURE AND OTHER EQUIPMENT (AIR BOXES, ETC.) AND CEILING MATERIAL SUPPORTED BY THE MAIN BEAM MUST NOT EXCEED THE ALLOWABLE DEFLECTION OF 1/360 OF ITS SPAN, DEFLECTION DATA MUST BE FURNISHED AND CERTIFIED BY THE MANUFACTURER.

AutoCAD SHX Text THE HANGER AND ITS CONNECTIONS SHALL SAFELY CARRY THE TOTAL SUPPORTED LOAD PLUS 200 LBS. CHANNEL CLIPS SHALL HAVE B5 AND A RATINGS MEETING THIS REQUIREMENT.

AutoCAD SHX Text AT EACH END OF LIGHT FIXTURE AN INTERLOCKING CROSS TEE OR LOCKING BAR MUST BE USED.

AutoCAD SHX Text b.

AutoCAD SHX Text 12" O.C.

AutoCAD SHX Text

METAL FURRING CHANNEL CLIP

AutoCAD SHX Text

WALL MOULDING

AutoCAD SHX Text

SOUND SEALANT

AutoCAD SHX Text a.

AutoCAD SHX Text

RECESSED LIGHT FIXTURE

AutoCAD SHX Text c.

AutoCAD SHX Text SURFACE OR PENDANT FIXTURES MUST BE INDEPENDENTLY SUPPORTED FROM 1 1/2" BLACK IRON OR FROM BUILDING STRUCTURE.

AutoCAD SHX Text d.

AutoCAD SHX Text

SOUND SEALANT

AutoCAD SHX Text

5/8" GWB

AutoCAD SHX Text

5/8" GYPUSM WALLBOARD

AutoCAD SHX Text

METAL CORNER BEAD

AutoCAD SHX Text

WALL TILE TCA W223

AutoCAD SHX Text

ORGANIC ADHESIVE BOND COAT

AutoCAD SHX Text

MOISTURE RESISTANT GWB

AutoCAD SHX Text

METAL STUDS

AutoCAD SHX Text

CERAMIC TILE

AutoCAD SHX Text

POLYMER-MODIFIED UNSANDED GROUT

AutoCAD SHX Text

WALL TILE TRANSITION DETAIL

AutoCAD SHX Text

ORGANIC ADHESIVE BOND COAT

AutoCAD SHX Text

MOISTURE RESISTANT GWB

AutoCAD SHX Text

METAL STUDS

AutoCAD SHX Text

CERAMIC TILE W/ BULLNOSE

AutoCAD SHX Text

NOTE: SEE TCA W223 FOR TYPICAL NOTES

AutoCAD SHX Text

PAINTED GWB

AutoCAD SHX Text

SEALANT

AutoCAD SHX Text

SHOWER ONLY WALL TILE TCA W224C-17

AutoCAD SHX Text

ORGANIC ADHESIVE BOND COAT

AutoCAD SHX Text

CEMENTITIOUS BACKER UNIT

AutoCAD SHX Text

METAL STUDS

AutoCAD SHX Text

CERAMIC TILE

AutoCAD SHX Text

POLYMER-MODIFIED UNSANDED GROUT

AutoCAD SHX Text

MOSAIC FLOOR TILE

AutoCAD SHX Text

CONCRETE

AutoCAD SHX Text

LATEX-PORTLAND CEMENT MORTAR BOND COAT

AutoCAD SHX Text

POLYMER-MODIFIED SANDED GROUT

AutoCAD SHX Text

CFT, FLOOR TILE TCA F122

AutoCAD SHX Text

FLUID APPLIED CRACK ISOLATION

AutoCAD SHX Text

WATER PROOF MEMBRANE

AutoCAD SHX Text

FLOOR TILE

AutoCAD SHX Text

CONCRETE

AutoCAD SHX Text

LATEX-PORTLAND CEMENT MORTAR BOND COAT

AutoCAD SHX Text

BACKER ROD

AutoCAD SHX Text

SAW-CUT CONTROL JOINT

AutoCAD SHX Text

SEALANT

AutoCAD SHX Text

FLUID APPLIED CRACK ISOLATION MEMBRANE

AutoCAD SHX Text

POLYMER-MODIFIED SANDED GROUT

AutoCAD SHX Text

BOND BREAKER TAPE

AutoCAD SHX Text

BACKER ROD

AutoCAD SHX Text

FLOOR TILE

AutoCAD SHX Text

CONCRETE

AutoCAD SHX Text

LATEX-PORTLAND CEMENT MORTAR BOND COAT

AutoCAD SHX Text

SEALANT

AutoCAD SHX Text

FLUID APPLIED CRACK ISOLATION MEMBRANE

AutoCAD SHX Text

POLYMER-MODIFIED SANDED GROUT

AutoCAD SHX Text

CONT ALUM RETAINER

AutoCAD SHX Text

#6 SHEET METAL SCREWS

AutoCAD SHX Text

1/4" RADIUS

AutoCAD SHX Text

IMPACT RESISTANT CONCEALED FASTENER PLASTIC CORNER GUARD

AutoCAD SHX Text

%%UACCESS DOOR SPECIFICATION:

AutoCAD SHX Text ACCESS DOOR SHALL BE 2'-0" x 2'-0".

AutoCAD SHX Text 1.

AutoCAD SHX Text

FRAME AND DOOR PANEL FRAME SHALL BE 16 GA STEEL.

AutoCAD SHX Text 2.

AutoCAD SHX Text 3.

AutoCAD SHX Text DOOR PANEL SHALL BE 20 GA STEEL WITH A CONTINUOUS STEEL ZINC PLATED HINGE. EXTERIOR LATCH OPERATED BY A FLUSH KEY. RIM CYLINDER LOCKS SHALL BE PROVIDED. DOOR SHALL BE INSULATED WITH FIRE RETARDANT INSULATION.

AutoCAD SHX Text 4.

AutoCAD SHX Text

ACCESS DOOR SYSTEM SHALL BE FACTORY PRIMED AND FIELD PAINTED.

AutoCAD SHX Text

SUBMIT SHOP DRAWINGS OF DOORS AND INSTALLATION DETAILS AND PRODUCT DATA.

AutoCAD SHX Text 5.

AutoCAD SHX Text

SEALANT

AutoCAD SHX Text

CONT ZINC PLATED STEEL HINGE

AutoCAD SHX Text

LATCH

AutoCAD SHX Text

FASTENER

AutoCAD SHX Text

2-1/2" METAL STUDS

AutoCAD SHX Text

GWB CEILING

AutoCAD SHX Text PROVIDE AN ACCESS DOOR AT ALL HARD CEILING LOCATIONS WHERE THERE IS SERVICEABLE EQUIPMENT ABOVE OR ANY WATER VALVES.

AutoCAD SHX Text 6.

AutoCAD SHX Text

PREFINISHED DOOR W/ FULL GLASS AND PULL HANDLE

AutoCAD SHX Text

SEE FLOOR PLANS FOR WALL TYPE 5

AutoCAD SHX Text

SEMI-RECESSED FIRE EXTINGUISHER CABINET

AutoCAD SHX Text

2 1/2" ROLLED EDGE

AutoCAD SHX Text

SIZED FOR 10 LB FIRE EXTINGUISHER

AutoCAD SHX Text

8" CMU

AutoCAD SHX Text

SEE STRUCTURAL DWGS FOR REINFORCEMENT

AutoCAD SHX Text

1" RADIUS

AutoCAD SHX Text

WALL TYPE 1A -SEE WALL TYPE DETAILS

AutoCAD SHX Text

WATERPROOFING MEMBRANE

AutoCAD SHX Text

SHOWER TILE BEYOND

AutoCAD SHX Text

SEALANT

AutoCAD SHX Text

FLOOR TILE

AutoCAD SHX Text

TERRAZZO WHEELCHAIR SHOWER RECEPTOR

AutoCAD SHX Text

DRAIN PIPE (SEE PLUMBING DWGS)

AutoCAD SHX Text

1/2" (MIN) MORTAR BED

AutoCAD SHX Text

FULLY APPLIED CRACK ISOLATION

AutoCAD SHX Text

2" SLAB DEPRESSION TO ACCOMODATE SHOWER RECEPTOR

AutoCAD SHX Text

AutoCAD SHX Text A601

AutoCAD SHX Text A601

AutoCAD SHX Text

AutoCAD SHX Text A601

AutoCAD SHX Text A601

AutoCAD SHX Text

AutoCAD SHX Text A601

AutoCAD SHX Text A601

AutoCAD SHX Text

AutoCAD SHX Text A601

AutoCAD SHX Text A601

AutoCAD SHX Text

FIN FL

AutoCAD SHX Text

EXTRUDED SANTOPRENE FILLER

AutoCAD SHX Text

CONCRETE SLAB

AutoCAD SHX Text

FASTENER AT 24" O.C.

AutoCAD SHX Text

LEVEL BASE

AutoCAD SHX Text

EXTRUDED VINYL HINGE

AutoCAD SHX Text

EXTRUDED ALUM TREAD RAIL

AutoCAD SHX Text

CONCRETE SLAB

AutoCAD SHX Text

FASTENER AT 24" O.C.

AutoCAD SHX Text

LEVEL BASE

AutoCAD SHX Text

EXTRUDED ALUM TREAD RAIL

AutoCAD SHX Text

FIN FL

AutoCAD SHX Text

ROOM FINISH SCHEDULE

AutoCAD SHX Text

MISCELLANEOUS

AutoCAD SHX Text

WALL

AutoCAD SHX Text

BASE

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text

CEILING

AutoCAD SHX Text

SPACE

AutoCAD SHX Text

NO.

AutoCAD SHX Text

AutoCAD SHX Text

VESTIBULE NO.1

AutoCAD SHX Text C-2

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

RM

AutoCAD SHX Text

AutoCAD SHX Text

TOOL CRIV AND MATERIAL STORAGE/ BENCH STOCK

AutoCAD SHX Text C-1

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

ACT

AutoCAD SHX Text

SSS

AutoCAD SHX Text

%%UFLOOR

AutoCAD SHX Text C-1

AutoCAD SHX Text

RB-1

AutoCAD SHX Text

4" RUBBER BASE

AutoCAD SHX Text

%%UBASE

AutoCAD SHX Text

%%UWALL

AutoCAD SHX Text

PT-1

AutoCAD SHX Text

PAINTED GYPSUM WALL BOARD-COLOR 1

AutoCAD SHX Text

%%UCEILING

AutoCAD SHX Text

ACT

AutoCAD SHX Text

ACOUSTICAL CEILING TILE 2'X2'

AutoCAD SHX Text

SEALED CONCRETE SYSTEM

AutoCAD SHX Text

AutoCAD SHX Text

BULK POL STO.

AutoCAD SHX Text C-1

AutoCAD SHX Text

AutoCAD SHX Text

PT-C

AutoCAD SHX Text

PT-D

AutoCAD SHX Text

PAINTED EXPOSED STEEL FRAME - COLOR: BLACK

AutoCAD SHX Text

AutoCAD SHX Text

VEHICLE MAINT. SHOP (COMBINED W/107,108,109,110,111)

AutoCAD SHX Text C-1

AutoCAD SHX Text

AutoCAD SHX Text

PT-C, PT-S

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TRANSPORTATION OFFICER

AutoCAD SHX Text C-2

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

ACT

AutoCAD SHX Text C-2

AutoCAD SHX Text

POLISHED CONCRETE SYSTEM

AutoCAD SHX Text

AutoCAD SHX Text

BREAKROOM

AutoCAD SHX Text C-2

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

ACT

AutoCAD SHX Text

PL, SS-2

AutoCAD SHX Text

AutoCAD SHX Text

SUPERINTENDENT (NCOIC)

AutoCAD SHX Text C-2

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

ACT

AutoCAD SHX Text

SS-3

AutoCAD SHX Text

AutoCAD SHX Text

CUSTOMER SUPPORT

AutoCAD SHX Text C-2

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

ACT

AutoCAD SHX Text

AutoCAD SHX Text

SIPR ROOM

AutoCAD SHX Text

CPT

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

ACT

AutoCAD SHX Text

AutoCAD SHX Text

OFFICER IN CHARGE (OIC)

AutoCAD SHX Text

CPT

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

ACT

AutoCAD SHX Text

SS-3

AutoCAD SHX Text

CPT

AutoCAD SHX Text

CARPET TILE

AutoCAD SHX Text

AutoCAD SHX Text

SERVICE COUNTER

AutoCAD SHX Text C-2

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

ACT

AutoCAD SHX Text

SS-3, SSS

AutoCAD SHX Text

AutoCAD SHX Text

WAREHOURSE (COMBIINED W/ 131)

AutoCAD SHX Text C-1

AutoCAD SHX Text

AutoCAD SHX Text

PT-C, PT-S

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

HAZMAT ROOM

AutoCAD SHX Text C-1

AutoCAD SHX Text

AutoCAD SHX Text

PT-C

AutoCAD SHX Text

PT-D

AutoCAD SHX Text

AutoCAD SHX Text

SUPERINDENDINT

AutoCAD SHX Text C-2

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

ACT

AutoCAD SHX Text

SS-3

AutoCAD SHX Text

AutoCAD SHX Text

RANGE SUPPLY EQUIP STORAGE

AutoCAD SHX Text C-2

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

ACT

AutoCAD SHX Text

SS-3

AutoCAD SHX Text

CERAMIC FLOOR TILE

AutoCAD SHX Text

CFT-1

AutoCAD SHX Text

CB-1

AutoCAD SHX Text

6" CERAMIC COVE BASE (WALL TILE)

AutoCAD SHX Text CERAMIC WALL TILE 3"x6", 1"X1" (SHOWER WALLS ONLY)

AutoCAD SHX Text

CWT

AutoCAD SHX Text

AutoCAD SHX Text

WOMEN'S RESTROOM (COMBINED W/ 122)

AutoCAD SHX Text

CFT-1

AutoCAD SHX Text

CB-1

AutoCAD SHX Text

CWT, PT-1

AutoCAD SHX Text

PT-1

AutoCAD SHX Text

PL, SS-1, SS-3

AutoCAD SHX Text

AutoCAD SHX Text

JANITOR'S CLOSET

AutoCAD SHX Text

CFT-1

AutoCAD SHX Text

CB-1

AutoCAD SHX Text

CWT

AutoCAD SHX Text

PT-1

AutoCAD SHX Text

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text C-2

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

ACT

AutoCAD SHX Text

AutoCAD SHX Text

ELECTRICAL ROOM

AutoCAD SHX Text C-1

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

AutoCAD SHX Text

SDT-1

AutoCAD SHX Text

STATIC DISSIPATIVE VINYL TILE

AutoCAD SHX Text

AutoCAD SHX Text

COMMUNICATIONS ROOM

AutoCAD SHX Text

SDT-1

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

ACT

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL ROOM

AutoCAD SHX Text C-1

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PAINT UNDERSIDE OF DECK AND EXPOSE ITEMS

AutoCAD SHX Text

AutoCAD SHX Text

CLASSROOM (COMBINED W/ 135, 136)

AutoCAD SHX Text C-2

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

ACT

AutoCAD SHX Text

PL, SS-3, SSS

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

CEILING ACCESS DOOR DETAIL

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A601

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

FIRE EXTINGUISHER

AutoCAD SHX Text

CABINET DETAIL

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A601

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

TYPICAL INTERIOR

AutoCAD SHX Text

CMU CORNER DETAIL

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A601

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

NTS

AutoCAD SHX Text

EXPOSED T-GRID CEILING SYSTEM AND GWB CEILING SYSTEM DETAILS

AutoCAD SHX Text

AutoCAD SHX Text A601

AutoCAD SHX Text

PT-C

AutoCAD SHX Text

%%UMISCELLANEOUS

AutoCAD SHX Text

SOLID SURFACE

AutoCAD SHX Text

SS-1

AutoCAD SHX Text

STAINLESS STEEL SURFACE

AutoCAD SHX Text

SSS

AutoCAD SHX Text

PL

AutoCAD SHX Text

PLASTIC LAMINATE

AutoCAD SHX Text

PX

AutoCAD SHX Text

EXPOSED STRUCTURE TO BE PAINTED

AutoCAD SHX Text

FOR ROOMS WITHOUT CEILINGS

AutoCAD SHX Text

ROOM FINISH SCHEDULE LEGEND

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

NTS

AutoCAD SHX Text

TYPICAL CERAMIC TILE DETAILS

AutoCAD SHX Text

AutoCAD SHX Text A601

AutoCAD SHX Text

PT-S

AutoCAD SHX Text

PAINTED CMU

AutoCAD SHX Text

PAINTED CONCRETE DECK

AutoCAD SHX Text

PT-D

AutoCAD SHX Text

SOLID SURFACE

AutoCAD SHX Text

SS-2

AutoCAD SHX Text

AutoCAD SHX Text

REFUELING VEHICLE SHOP

AutoCAD SHX Text C-1

AutoCAD SHX Text

AutoCAD SHX Text

PT-C, PT-S

AutoCAD SHX Text

PT-D

AutoCAD SHX Text

SOLID SURFACE

AutoCAD SHX Text

SS-3

AutoCAD SHX Text

PAINTED CONCRETE SURFACE

AutoCAD SHX Text

PT-S

AutoCAD SHX Text NOTES: 1. REFER TO SIGNAGE SCHEDULE FOR ROOM SIGNAGE REFER TO SIGNAGE SCHEDULE FOR ROOM SIGNAGE NUMBERS AND LOCATIONS.

AutoCAD SHX Text

PAINTED GYPSUM CEILING BOARD-COLOR 1

AutoCAD SHX Text

PT-1

AutoCAD SHX Text

PAINTED GYPSUM CEILING BOARD-COLOR 2

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

PAINTED GYPSUM WALL BOARD-COLOR 2

AutoCAD SHX Text

AutoCAD SHX Text

FIRE PUMP ROOM

AutoCAD SHX Text C-1

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-C

AutoCAD SHX Text

PT-D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

CORNER GUARD

AutoCAD SHX Text

PLAN DETAIL

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text A601

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

TERRAZZO SHOWER BASE DETAIL

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A601

AutoCAD SHX Text

AutoCAD SHX Text

VESTIBULE NO.2

AutoCAD SHX Text C-2

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

RM

AutoCAD SHX Text

AutoCAD SHX Text

READINNESS STAFF

AutoCAD SHX Text

CPT

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

ACT

AutoCAD SHX Text

SS-3

AutoCAD SHX Text

AutoCAD SHX Text

COMMANDER SUPPORT STAFF

AutoCAD SHX Text

CPT

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

ACT

AutoCAD SHX Text

SS-3

AutoCAD SHX Text

AutoCAD SHX Text

PRODUCTION CONTROLS (COMBINED W/ 117)

AutoCAD SHX Text C-2

AutoCAD SHX Text

RB

AutoCAD SHX Text

PT-2

AutoCAD SHX Text

ACT

AutoCAD SHX Text

SS-3, SSS

AutoCAD SHX Text

AutoCAD SHX Text

MEN'S RESTROOM (COMBINED W/ 124)

AutoCAD SHX Text

CFT-1

AutoCAD SHX Text

CB-1

AutoCAD SHX Text

CWT, PT-1

AutoCAD SHX Text

PT-1

AutoCAD SHX Text

PL, SS-1, SS-3

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

VESTIBULE NO.1

AutoCAD SHX Text

RECESSED MAT PLAN

AutoCAD SHX Text 3"

AutoCAD SHX Text 8A

AutoCAD SHX Text A601

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

VESTIBULE NO.2

AutoCAD SHX Text

RECESSED MAT PLAN

AutoCAD SHX Text 3"

AutoCAD SHX Text 8B

AutoCAD SHX Text A601

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

TYPICAL

AutoCAD SHX Text

RECESSED MAT DETAIL

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A601

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text = 1'-0"

AutoCAD SHX Text

TYPICAL

AutoCAD SHX Text

RECESSED MAT DETAIL

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text A601

AutoCAD SHX Text

RM

RECESSED DOOR MAT

A602

DOOR AND FRAME SCHEDULE

AND DETAILS

BEN

PF

RKF

D W

G

N

A M

E

C

U

S E

R S

O

U A

P P

D A

T A

L O

C A

L P

R O

J E

C T

W I S

E W

O R

K D

I R

M

O T

T U

S E

P

W D

M S

A

D

V

E

D

A T

E

O

U

O

T

D

A T

E

P

M

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

APRIL 13 2022

507101745

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

P r o j e c t

N o

E

U B

C

P o r t

C l i n t o n

O

H

C a m p

P e r r y

R u a d r o n

C

B

A

D

C

B

A

54321

1 W oo d A ve S ou th

Ise lin

, N J 0

-4

3.3

.34

| m ott ma c.c om

R E

D

H

O R g i s t i c s

C o m p l e x

B-3 SUBMISSION - BID SET

BG

SCALE: 1-1/2" = 1'-0"

SCALE: 1/4" = 1'-0"

0 2

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text

PREFINISHED ALUM DOOR

AutoCAD SHX Text

INSULATED AND LAMINATED GLASS

AutoCAD SHX Text D

AutoCAD SHX Text

LAMINATED GLASS

AutoCAD SHX Text

HOLLOW METAL DOOR

AutoCAD SHX Text B

AutoCAD SHX Text

SS HOOD

AutoCAD SHX Text

ROLLING COUNTER DOOR

AutoCAD SHX Text

HOLLOW METAL DOOR

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text G

AutoCAD SHX Text

SECTIONAL DOOR

AutoCAD SHX Text

SECTIONAL DOOR

AutoCAD SHX Text

SECTIONAL DOOR

AutoCAD SHX Text

LAMINATED GLASS

AutoCAD SHX Text

HM FRAME

AutoCAD SHX Text

SS FRAME

AutoCAD SHX Text

WELDED CORNER

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

HM FRAME

AutoCAD SHX Text

AutoCAD SHX Text

HM FRAME

AutoCAD SHX Text

INSULATED AND LAMINATED GLASS

AutoCAD SHX Text

AutoCAD SHX Text

INSULATED AND LAMINATED GLASS

AutoCAD SHX Text

AutoCAD SHX Text

STOREFRONT ALUM FRAME

AutoCAD SHX Text

FINISH FLOOR

AutoCAD SHX Text

MARBLE SADDLE

AutoCAD SHX Text

DOOR

AutoCAD SHX Text

CONC SLAB

AutoCAD SHX Text

ADA ALUM SADDLE SET IN SEALANT

AutoCAD SHX Text

DOOR

AutoCAD SHX Text

DOOR SWEEP

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

VINYL TRANSITION STRIP

AutoCAD SHX Text

DOOR

AutoCAD SHX Text

FINISH FLOOR

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

FINISH FLOOR

AutoCAD SHX Text

NOTE: STC-45 FOR DOOR 17

AutoCAD SHX Text

HM FRAME

AutoCAD SHX Text

WALL TYPE 5

AutoCAD SHX Text

3 FASTENERS PER JAMB

AutoCAD SHX Text

WALL TYPE 5

AutoCAD SHX Text

2- 3 5/8" 18 GAV. METAL STUDS

AutoCAD SHX Text

2- 3 5/8" 18 GAV. METAL STUDS

AutoCAD SHX Text

SEALANT BOTH SIDES

AutoCAD SHX Text

JAMB SHOWN

AutoCAD SHX Text

HEAD SHOWN

AutoCAD SHX Text

HM FRAME

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SS MOUNTING MEMBER

AutoCAD SHX Text

JAMB SHOWN

AutoCAD SHX Text

WALL TYPE 5

AutoCAD SHX Text

PILE LINING

AutoCAD SHX Text

FASTENERS AT 18" O.C. MAX

AutoCAD SHX Text

2- 3 5/8" 18 GAV. METAL STUDS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SEALANT ON BOTH SIDES

AutoCAD SHX Text

AutoCAD SHX Text

SS JAMB TRIM

AutoCAD SHX Text

AutoCAD SHX Text

JAMB SHOWN

AutoCAD SHX Text

BACKER ROD AND SEALANT (ON BOTH SIDES)

AutoCAD SHX Text

HM FRAME

AutoCAD SHX Text

EXPANSION BOLT WITH WALL ANCHOR (3 PER JAMB)

AutoCAD SHX Text

WALL TYPE 3

AutoCAD SHX Text

2- 3 5/8" 18 GAV. METAL STUDS

AutoCAD SHX Text

GROUT SOLID

AutoCAD SHX Text

PRESSURE TREATED WOOD BLOCKING

AutoCAD SHX Text

COUNTER BELOW

AutoCAD SHX Text

NOTE: SEE DETAILS ON SHEET A604

AutoCAD SHX Text

NOTE: SEE DETAILS ON SHEET A604

AutoCAD SHX Text

NOTE: USE WALL TYPE 7 FOR DOOR 17

AutoCAD SHX Text

NOTE: USE WALL TYPE 7 FOR DOOR 17 USE WALL TYPE 7 FOR DOOR 17

AutoCAD SHX Text

BACKER ROD AND SEALANT (ON BOTH SIDES)

AutoCAD SHX Text

HM FRAME

AutoCAD SHX Text

BOLT WITH WALL ANCHOR (3 PER JAMB)

AutoCAD SHX Text

PRESSURE TREATED WOOD BLOCKING

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

JAMB SHOWN

AutoCAD SHX Text

HEAD SHOWN

AutoCAD SHX Text

JAMB SHOWN

AutoCAD SHX Text

HM FRAME

AutoCAD SHX Text

PRESSURE TREATED WOOD BLOCKING

AutoCAD SHX Text

BACKER ROD AND SEALANT (ON BOTH SIDES)

AutoCAD SHX Text

AutoCAD SHX Text

HEAD SHOWN

AutoCAD SHX Text

AutoCAD SHX Text

JAMB SHOWN

AutoCAD SHX Text

AutoCAD SHX Text

HEAD SHOWN

AutoCAD SHX Text

BACKER ROD AND SEALANT (ON BOTH SIDES)

AutoCAD SHX Text

HM FRAME

AutoCAD SHX Text

EXPANSION BOLT WITH WALL ANCHOR (3 PER JAMB)

AutoCAD SHX Text

PRESSURE TREATED WOOD BLOCKING

AutoCAD SHX Text

AutoCAD SHX Text

HEAD SHOWN

AutoCAD SHX Text

BOND BEAM (SEE STRUCT DWGS)

AutoCAD SHX Text

HM FRAME

AutoCAD SHX Text

PRESSURE TREATED WOOD BLOCKING

AutoCAD SHX Text

BACKER ROD AND SEALANT (ON BOTH SIDES)

AutoCAD SHX Text

GROUT SOLID

AutoCAD SHX Text

WALL TYPE 3

AutoCAD SHX Text

BOND BEAM (SEE STRUCT DWGS)

AutoCAD SHX Text

HM FRAME

AutoCAD SHX Text

BACKER ROD AND SEALANT (ON BOTH SIDES)

AutoCAD SHX Text

GROUT SOLID

AutoCAD SHX Text

PRESSURE TREATED WOOD BLOCKING

AutoCAD SHX Text

GROUT SOLID

AutoCAD SHX Text

AutoCAD SHX Text

JAMB SHOWN

AutoCAD SHX Text

STEEL JAMB TRIM

AutoCAD SHX Text

WALL TYPE 1

AutoCAD SHX Text

EXTERIOR

AutoCAD SHX Text

BOND BEAM LINTEL (SEE STRUCT DWGS)

AutoCAD SHX Text

INSULATED/ LAMINATED GLASS

AutoCAD SHX Text CONT 22 GA PREFINISHED GALVALUME JAMB FLASHING RIVETED TO PANEL AND LINER FLASHING AT 12" O.C. (RIVET TO MATCH PANEL COLOR)

AutoCAD SHX Text

EXTERIOR

AutoCAD SHX Text

ALUM CORNER BEAD

AutoCAD SHX Text

PRESSURE TREATED WOOD BLOCKING

AutoCAD SHX Text

ALUM CORNER BEAD

AutoCAD SHX Text

HOLLOW METAL FRAME

AutoCAD SHX Text

BACKER ROD AND SEALANT

AutoCAD SHX Text

BACKER ROD AND SEALANT (ON BOTH SIDES)

AutoCAD SHX Text

SEALANT

AutoCAD SHX Text

EXPANSION BOLT WITH WALL ANCHOR (4 PER JAMB)

AutoCAD SHX Text

PRESSURE TREATED WOOD BLOCKING

AutoCAD SHX Text

BACKER ROD AND SEALANT (ON BOTH SIDES)

AutoCAD SHX Text

SEALANT

AutoCAD SHX Text

HOLLOW METAL FRAME

AutoCAD SHX Text

GLASS STOP W/ SS SECURITY SCREWS SET IN SEALANT

AutoCAD SHX Text

GLAZING TAPE BOTH SIDES AND SET GLASS IN SEALANT

AutoCAD SHX Text

HOLLOW METAL DOOR

AutoCAD SHX Text

WALL TYPE 1

AutoCAD SHX Text

WALL TYPE 4/4A/4B

AutoCAD SHX Text

WALL TYPE 4/4A/4B

AutoCAD SHX Text

WALL TYPE 2

AutoCAD SHX Text

WALL TYPE 2

AutoCAD SHX Text

WALL TYPE 3

AutoCAD SHX Text

SS MOUNTING MEMBER

AutoCAD SHX Text

PILE LINING

AutoCAD SHX Text

FASTENERS AT 18" O.C. MAX

AutoCAD SHX Text

BRACKET MOUNTING FLAT

AutoCAD SHX Text

SEALANT BELOW

AutoCAD SHX Text

CONT 22 GA PREFINISHED GALVALUME LINER FLASHING

AutoCAD SHX Text CONT 22 GA PREFINISHED GALVALUME JAMB FLASHING RIVETED TO PANEL AND LINER FLASHING AT 12" O.C. (RIVET TO MATCH PANEL COLOR)

AutoCAD SHX Text CONT 22 GA PREFINISHED GALVALUME END PANEL FLASHING RIVETED TO PANEL AT 12" O.C. (RIVET TO MATCH PANEL COLOR)

AutoCAD SHX Text .040" THK PREFINISHED ALUM 2 PIECE FLASHING W/ HEMMED DRIP EDGE AND EXTERIOR HEAD TRIM

AutoCAD SHX Text

1/8" RIVETS@ 8" O.C. AND FLASHING SEALANT TAPE

AutoCAD SHX Text CONT 22 GA PREFINISHED GALVALUME END PANEL FLASHING RIVETED TO PANEL AT 12" O.C. (RIVET TO MATCH PANEL COLOR)

AutoCAD SHX Text .040" THK PREFINISHED ALUM 2 PIECE FLASHING W/ HEMMED DRIP EDGE AND EXTERIOR HEAD TRIM

AutoCAD SHX Text

1/8" RIVETS @ 8" O.C.AND FLASHING SEALANT TAPE

AutoCAD SHX Text

PAINTED STEEL HEAD CHANNEL

AutoCAD SHX Text

SECTIONAL DOOR VERTICAL TRACK ASSEMBLY

AutoCAD SHX Text

AutoCAD SHX Text

JAMB SHOWN

AutoCAD SHX Text

STL CHANNEL BELOW

AutoCAD SHX Text

PAINTED STEEL JAMB CHANNEL

AutoCAD SHX Text

SECTIONAL DOOR VERTICAL TRACK ASSEMBLY

AutoCAD SHX Text

WEATHER SEAL

AutoCAD SHX Text

SECTIONAL DOOR

AutoCAD SHX Text

AutoCAD SHX Text

HEAD SHOWN

AutoCAD SHX Text

AutoCAD SHX Text

JAMB SHOWN

AutoCAD SHX Text

AutoCAD SHX Text

HEAD SHOWN

AutoCAD SHX Text

BOND BEAM (SEE STRUCT DWGS)

AutoCAD SHX Text

HM FRAME

AutoCAD SHX Text

BACKER ROD AND SEALANT (ON BOTH SIDES)

AutoCAD SHX Text

PRESSURE TREATED WOOD BLOCKING

AutoCAD SHX Text

WALL TYPE 4A

AutoCAD SHX Text

WALL TYPE 2

AutoCAD SHX Text

AutoCAD SHX Text

JAMB SHOWN

AutoCAD SHX Text

AutoCAD SHX Text

HEAD SHOWN

AutoCAD SHX Text

BACKER ROD AND SEALANT (ON BOTH SIDES)

AutoCAD SHX Text

HM FRAME

AutoCAD SHX Text

BOLT WITH WALL ANCHOR (3 PER JAMB)

AutoCAD SHX Text

PRESSURE TREATED WOOD BLOCKING

AutoCAD SHX Text

HM FRAME

AutoCAD SHX Text

PRESSURE TREATED WOOD BLOCKING

AutoCAD SHX Text

BACKER ROD AND SEALANT (ON BOTH SIDES)

AutoCAD SHX Text

WALL TYPE 2A

AutoCAD SHX Text

WALL TYPE 2

AutoCAD SHX Text

TORX HEAD FASTNER THROUGH PANEL AND FASTENED TO HAT CHANNELS

AutoCAD SHX Text

SEALANT BELOW

AutoCAD SHX Text

CONT 22 GA PREFINISHED GALVALUME LINER FLASHING

AutoCAD SHX Text CONT 22 GA PREFINISHED GALVALUME JAMB FLASHING RIVETED TO PANEL AND LINER FLASHING AT 12" O.C. (RIVET TO MATCH PANEL COLOR)

AutoCAD SHX Text CONT 22 GA PREFINISHED GALVALUME END PANEL FLASHING RIVETED TO PANEL AT 12" O.C. (RIVET TO MATCH PANEL COLOR)

AutoCAD SHX Text .040" THK PREFINISHED ALUM 2 PIECE FLASHING W/ HEMMED DRIP EDGE AND EXTERIOR HEAD TRIM

AutoCAD SHX Text

1/8" RIVETS @ 8"O.C. AND FLASHING SEALANT TAPE

AutoCAD SHX Text

SEALANT BEYOND

AutoCAD…