Summary: Addendum No. 1 Drawings - Building 53 Security System Upgrades

This document comprises detailed architectural and electrical drawings for the West Virginia General Services Building 53 Security System Upgrades project located at 153 West Main Street, Clarksburg, West Virginia 26301. The project involves comprehensive security system modernization including access control panel installation, security camera deployment, card reader integration, door contact systems, and wireless lock interfaces throughout a multi-story government building. The scope encompasses demolition plans for all building levels (basement through roof), proposed security plans with device placement specifications, and detailed installation instructions. Security equipment includes multiple camera types (ranging from 4MP to 12MP with various mounting configurations), multi-technology card readers (MTB15 model), door contacts, wireless locks (Schlage AD-400), and panel interface boards. The design incorporates five security network racks distributed across building floors with fiber optic connectivity (12-strand OM4 armored cable) and includes provisions for access control panels, uninterruptible power supplies, network switches, and monitoring stations. Installation details address requirements for plenum-rated cabling, conduit routing, fire-rated penetration protection, ceiling-mounted and surface-mounted device specifications, and integration with existing infrastructure including legacy Honeywell and Schlage systems.

The project documentation specifies that existing functional equipment including Schlage AD-400 wireless network locks and panel interface boards shall remain integrated into the new system, with migration occurring door-by-door to ensure continuous security. The contractor is required to disconnect and remove only designated equipment while maintaining continuity for devices remaining in service. All communication cables must be installed in conduit, cable tray, or supported by cable hooks with bushings at conduit ends and cable hooks above accessible ceilings. Electrical power requirements include two 120V, 20A circuits for each security network rack location, with power derived from the nearest electrical panel. The drawings establish specific camera mounting heights (14-24 feet AFF depending on location), specify fire alarm interface requirements, and mandate surge protection for all exterior cameras. Labeling requirements are extensive, including cable identification with floor designation, IDF location, jack number, and jack color. The project requires coordination among general contractors, security contractors, door hardware suppliers, and electrical contractors to ensure proper installation sequencing and interface functionality during the transition from existing to new systems.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOT FOR CONSTRUCTION

ZDS Design/ Consulting Services

Mechanical * Electrical * IAQ * Energy * Commissioning

135 Corporate Center Dr., Suite 532 Scott Depot, WV 25560

Ph: (304) 755-0075 Fx: (304) 755-0076

Web: www.zdsdesign.com Email: contact@zdsdesign.com

OWNER REVIEW SET

C :\U se rs

\e di so n.

ad ki ns \D oc um en ts

\G

SD

2C

_2

4-

-0 4_

BL

D

G

C

LA

R

KS

BU

R

G _e di so n.

ad ki ns

.rv t

WEST VIRGINIA GENERAL SERVICES

BUILDING 53 SECURITY SYSTEM UPGRADES

ZDS Project Number: GSD-252-C 8/5/2026

153 West Main Street Clarksburg, WV 26301

PROJECT VICINITY MAP

OS

DL

CO

T

CO

LC

F

F

F

DH

DCL

XXX

XXXX

XX

J

J F1

DO

M

N

X

TV

XXXX

CR

CK

TV

CC

DC

ES

IC

ML

RX

REX

MD

XXX

OS

1P 1 Pole (2P, 3P, 4P, ETC.)

A, Amp Ampere AC Above Counter ACLG Above Ceiling ADO Automatic Door Opener AF Amp Frame AFF Above Finished Floor AFG Above Finished Grade AFI Arc Fault Circuit

Interrupter AHU Air Handling Unit AL Aluminum ALT Alternate AMP Ampere AMPL Amplifier ANNUN Annunciator APPROX Approximately AQ-STAT Aquastat ARCH Architect, Architectural AS Amp Switch AT Amp Trip ATS Automatic Transfer Switch AUTO Automatic AUX Auxiliary AV Audio Visual AWG American Wire Gauge BATT Battery BD Board BLDG Building BMS Building Management System C Conduit CAB Cabinet CAT Catalog CATV Cable Television CB Circuit Breaker CCTV Closed Circuit Television CKT Circuit CLG Ceiling COMB Combination CMPR Compressor CONN Connection CONST Construction CONT Continuation Or Continuous CONTR Contractor CONV Convector CP Circulating Pump CRT Cathode-Ray Tube CT Current Transformer CTR Center CU Copper DCP Domestic Water Circulating Pump DEPT Department DET Detail DIA Diameter DISC Disconnect DIST Distribution DN Down DPR Damper DS Safety Disconnect Switch DT Double Throw DWG Drawing EC Electrical Contractor ELEC Electric, Electrical ELEV Elevator ELU Emergency Lighting Unit EM Emergency EMS Energy Management System EMT Electrical Metallic Tubing EP Electric Pneumatic EQUIP Equipment EWC Electric Water Cooler EXIST Existing EXH Exhaust EXP Explosion Proof FA Fire Alarm FABP Fire Alarm Booster Power

Supply Panel FACP Fire Alarm Control Panel FCU Fan Coil Unit FIXT Fixture FLR Floor FLUOR Fluorescent FU Fuse FUDS Fused Safety Disconnect Switch GA Gauge GAL Gallon GALV Galvanized GC General Contractor GEN Generator GFI Ground Fault Circuit Interrupter GFP Ground Fault Protector GND Ground GRS Galvanized Rigid Steel (Conduit) GYP BD Gypsum Board HOA Hands-Off-Automatic Switch HORIZ Horizontal HP Horsepower HPF High Power Factor HT Height HTG Heating HTR Heater HV High Voltage HVAC Heating, Ventilating And Air

Conditioning IC Interrupting Capacity IG Isolated Ground IMC Intermediate Metal Conduit INCAND Incandescent IR Infrared I/W Interlock With J-BOX Junction Box KV Kilovolt KVA Kilovolt-Ampere KVAR Kilovolt-Ampere Reactive KW Kilowatt KWH Kilowatt Hour LOC Locate Or Location LT Light LTG Lighting LTNG Lightning LV Low Voltage MAX Maximum MAG.S Magnetic Starter M/C Momentary Contact MC Mechanical Contractor

Electrical Abbreviations

Electrical DeviceTags: Uppercase letter(s) indicates Panel ID and circuit number. Lowercase letter indicates designation of controlling switch (where applicable).

Switch ID indicated by a lowercase letter. Switch IDs are unique per space. A switch with an ID "a" controls all devices within the space in which it is located tagged with "a". A switch without a tagged ID controls all lighting fixtures within a space. ID tags may be used on control devices other than switches, such as occupancy sensors or contactors.

Equipment Tags: Equipment ID is indicated by an underlined tag adjacent to the equipment. See the equipment connection schedule for description, electrical requirements, and panel and circuit number. Symbols/graphic appearance of equipment varies.

Solid, arced lines connecting equipment, devices, or fixtures indicate unswitched power circuiting. Wires are only intended to indicate to what circuit devices are connected. Actual connections, circuit routing, installtion, junction boxes, etc. shall be field-determined by the contractor.

Home run to branch circuit panelboard. The equipment name and circuit number(s) are indicated, separated by a hyphen. Homeruns are only intended to indicate panel and circuit number. Actual homerun location shall be field-determined by the contractor.

Power Symbols

Electrical Symbol Legend

Room

MCB Main Circuit Breaker MCC Motor Control Center MDC Main Distribution Center MDP Main Distribution Panel MFR Manufacturer MFS Main Fused Disconnect Switch MH Manhole MIC Microphone MIN Minimum MISC Miscellaneous MLO Main Lugs Only MMS Manual Motor Starter MOA Multioutlet Assembly MSP Motor Starter Panelboard MSBD Main Switchboard MSS Motor Starter Switch MT Mount MT.C Empty Conduit MTS Manual Transfer Switch MTR Motor, Motorized N.C. Normally Closed NEC National Electrical Code NEMA National Electrical

Manufacturer's Association NFDS Non-Fused Safety Disconnect

Switch NIC Not In Contract NL Night Light N.O. Normally Open NPF Normal Power Factor NTS Not To Scale OC On Center OH Overhead OL Overloads PA Public Address PB Pull Box Or Pushbutton PE Pneumatic Electric PED Pedestal PF Power Factor PH Phase PIV Post Indicating Valve PNL Panel PP Power Pole PR Pair PRI Primary PROJ Projection PRV Power Roof Ventilator PT Potential Transformer PVC Polyvinyl Chloride (Conduit) PWR Power QUAN Quantity RCPT Receptacle REQD Required RM Room RSC Rigid Steel Conduit RTU Roof Top Unit SC Surface Conduit SEC Secondary SHT Sheet SIM Similar SLD Single-Line Diagram S/N Solid Neutral SPEC Specification SPKR Speaker SP Spare SPP Single-Point Power SR Surface Raceway SS Stainless Steel SSW Selector Switch S/S Stop/Start Pushbuttons STA Station STD Standard SURF Surface Mounted SW Switch SWBD Switchboard SYM Symmetrical SYS System TEL Telephone TERM Terminal TL Twist Lock TR Tamper Resistant T-STAT Thermostat TTC Telephone Terminal Cabinet TV Television TVTC Television Terminal Cabinet TYP Typical UC Under Counter UE Underground Electrical UG Underground UH Unit Heater UT Underground Telephone UTIL Utility UV Ultraviolet V Volt VA Volt-Amperes VDT Video Display Terminal VERT Vertical VFD Variable Frequency Drive VOL Volume W Watt W/ With WG Wire Guard WH Water Heater W/O Without WP Weatherproof XFMR Transformer XFR Transfer

∠ Angle @ At ▲ Delta ' Feet " Inches # Number Ø Phase C Center Line P Plate

Exit Light, Wall-Mounted.

Shading and arrows indicate faces and directional chevrons.

Wall-mounted fixtures, Typical (Various Symbols)

Emergency Lighting Unit, Wall-Mounted, Remote Battery

Emergency Lighting Unit, Wall-Mounted, Integral Battery

Emergency Lighting Unit, Ceiling-Mounted, Integral Battery Emergency Lighting Unit, Ceiling-Mounted, Remote Battery

Lighting Fixtures, Typical, Rectangular (Various Symbols) Filled circles indicate recessed.

Open circles indicate surface-mounted.

Diagonal line indicates lensed.

Outer dots indicate suspended.

Lighting Fixtures, Typical, Round (Various Symbols) Center dot indicates pendant.

Diagonal line indicates lensed.

Chevron indicates wall wash.

Strip Fixture

Directional Light, Track Light, Flood Light

Exit Light, Ceiling-Mounted.

Shading and arrows indicate faces and directional chevrons.

Linear Light, Tape Light

Exit/ELU Combo

Diagonal hatch indicates light on a critical circuit.

Solid hatch indicates light on an emergency or life safety circuit.

Pole/Area Lights

Post-Top Area Light

Bollard Light

Single-Pole Switch Two-Pole Switch Three-Pole Switch Switch Modifiers:

3: 3-Way 4: 4-Way K: Keyed D: Dimming T: Timer

OS: Occupancy Sensor VS: Vacancy Sensor AC: Above-Counter LV: Low-Voltage M: Motor-Rated

Lighting Contactor

Lighting Control Panel

Occupancy Sensor

Daylight Harvesting Sensor

Smoke Detector

Heat Detector

Carbon Monoxide Detector

Beam Detector T: Transmitter R: Receiver

Combination Detector (Up to Three)

Duct Smoke Detector

Manual Pull Station

Horn, Wall

Horn, Ceiling

Strobe, Wall, Candela as indicated

Strobe, Ceiling, Candela as indicated

Horn/Strobe, Wall, Candela as indicated

Horn/Strobe, Ceiling, Candela as indicated

Remote Indicator w/ Test Switch, Wall

Remote Indicate w/ Test Switch, Ceiling

Door Holder

Door Closer

Fire Service Phone

Addressible Module AIM: Addressible Input Module AOM:Addressible Output Control Module AIO: Addressible Input/Output Module

Fire Alarm Control Unit EVAC: Voice Evacuation Control Panel FAA: Fire Alarm Annunciator FACP: Fire Alarm Control Panel FATC: Fire Alarm Terminal Cabinet NACP: Notification Appliance Circuit Panel FAMN: Fire Alarm Mass Notification Control Panel

Supervisory or Interface Device PIV: Post Indicator Valve Supervisory PS: Pressure Switch R: Non-Addressible Relay VS: Valve Supervisory Switch WF: Water Flow Switch

Simplex Receptacle

Duplex Receptacle

Quadruplex Receptacle

Special Receptacle, Type as Indicated W all Ce ilin g

Flo or

Receptacle Modifiers:

##": Height AFF OC AC: Above Counter GFI: Ground-Fault Circuit Interrupter WP: Weatherproof In-Use Cover

Half shading indicates split (typically switched) Outside shading indicates emergency circuit Center shading indicates isolated ground

Multioutlet Assembly Filled squares indicate 120V outlet Open squares indicate with USB

Cord Reel, Device Varies

Drop Cord, Device Varies

Junction Box Floor Box, see schedule for type

Emergency Power Off

Door Opener Push Plate

Power Meter Safety Switch, Fused

Safety Switch, Unfused

Motor Starter

Combination Starter/Disconnect

Ground Rod

Ground Rod with Test Well

Lightning Protection Air Terminal

Lightning Protection Conductor Splice

Static Ground Receptacle

Data Outlet

Telephone Outlet

Data/Telephone Outlet

W all

Ce ilin g

Flo or

Outlet Modifiers:

##": Height AFF OC AC: Above Counter

Wireless Access Point

Nurse Call Corridor Light Number of lights as indicated

Nurse Call Device B: Code Blue D: Duty Station E: Emergency P: Patient Call S: Staff

TV Outlet

Nurse Call Control Unit NCAP: Nurse Call Annunciator Panel NCHS: Nurse Call Host Constroller NCPA: Nurse Call Power Supply NCTC: Nurse Call Terminal Cabinet NCUPS: Uninterruptable Power Supply

Lighting Symbols

Contactor

Single-Pole Switch Two-Pole Switch Three-Pole Switch Switch Modifiers:

K: Keyed T: Timer AC: Above-Counter M: Motor-Rated

Fire Alarm Symbols

Grounding and Lightning Protection Symbols

Security Camera PTZ: Pan/Tilt/Zoom

Card Reader

Card Reader with Keypad

Closed Circuit TV Outlet

Door Contact

Electric Strike

Intercom

Magnetic Lock

Request to Exit Button

Request to Exit Sensor

Motion Detector

Security Control Unit SCP: Security Control Panel SPS: Security Power Supply Unit ACP: Access Control Panel WI: Wiegand Interface Unit PI: Wireless Lock Panel Interface Board IAC: Networked Lock with Integrated

Reader SWKS: Security Workstation MON: Video Monitor ARAM: Area of Rescue Assistance

Master Station ARAR: Area of Rescue Assistance

Remote Station

Telecom Symbols

Nurse Call Symbols

Security Symbols a

A A1a

Equipment is tagged with Panel Name and with Panel ID in parentheses. Panel ID is intended as a design documentation aid only. Do not include Panel ID in field-applied circuit directories or labels.

Hatched fill indicates distribution panel or switchboard.

Solid fill indicates branch panel or load center.

Dashed box indicates code-required clearance (width and depth).

Door indicates front of recessed panel.

Panelboards are assigned an abbreviated indicator (or Panel ID) for use with circuit numbers. Panel ID is listed within the panel schedule and in the panel abbreviation schedule.

Power Distribution Equipment

HP

1A

(B

LP

1A

(C

MD

P(

A)

SB1(S)

Devices and fixtures are tagged with Panel ID and circuit number. For example, a device tagged with "A1" indicates the device is circuited to panel designated "A," circuit number 1. The panel schedule circuit number contans both the panel abbreviation and the circuit number.

XX-1

Transformer: Typically transformer names begin with or contain the letter "T". See Single-Line Diagram for description and requirements.

T1

Dashed, arced lines connecting equipment, devices, or fixtures indicate switched power.

Absence of a switch designation on a lighting fixture indicates fixture is controlled by the only switch in the space. An "x" in place of the switch designation indicates unswitched.

Bottom Value, Lowercase Letter: Switch ID

Lighting Tags

Top Value: Fixture Type ID (Underlined)

Bottom Value, Uppercase Letter(s): Panel ID Bottom Value, Number(s): Circuit Number a a

C1a

Wiring

Power Device and Equipment Tags

Construction Phasing

Existing to Remain

Existing to Be Demolished

New

(Typical All Symbols and Equipment)

Existing to Be Demolished

Area Not in Contract

Miscellaneous

Keynote

Callout:

Top Value: Detail Number on Sheet Bottom Value: Sheet Number of Detail

Room Name and Number

Smoke Damper

FILE:

DRAWN BY:

CHECKED BY:

PROJ. NO:

DRAWING NO:

DRAWING TITLE:

PROJECT NAME:

http://www.ZDSDesign.com

135 Corporate Center Drive Suite 532 Scott Depot, WV 25560

TEL 304/755-0075

FAX 304/755-0076

THIS SQUARE APPEARS 1/2"x1/2"

ON FULL SIZE SHEETS

CLIENT:

XXX

C :\U se rs

\e di so n.

ad ki ns \D oc um en ts

\G

SD

2C

_2

4-

-0 4_

BL

D

G

C

LA

R

KS

BU

R

G _e di so n.

ad ki ns

.rv t

8/

/2

:3 7:

P

M

53-E-001

EA

TZ3

GSD-252-C

ELECTRICAL TITLE

SHEET

BUILDING 53 SECURITY

SYSTEM UPGRADES

153 West Main Street Clarksburg, WV 26301

WEST VIRGINIA

GENERAL SERVICES

ELECTRICAL SHEET INDEX

53-C001 COVER SHEET

53-E-001 ELECTRICAL TITLE SHEET

53-TD-101 DEMO PLAN BASEMENT

53-TD-102 DEMO PLAN FIRST FLOOR

53-TD-103 DEMO PLAN SECOND FLOOR

53-TD-104 DEMO PLAN THIRD FLOOR

53-TD-105 DEMO PLAN FOURTH FLOOR

53-TD-106 DEMO PLAN ROOF

53-TD-107 DEMO PLAN SITE

53-TY-101 BASEMENT SECURITY PLAN

53-TY-102 FIRST FLOOR SECURITY PLAN

53-TY-103 SECOND FLOOR SECURITY PLAN

53-TY-104 THIRD FLOOR SECURITY PLAN

53-TY-105 FOURTH FLOOR SECURITY PLAN

53-TY-106 ROOF SECURITY PLAN

53-TY-107 SITE SECURITY PLAN

53-TY-501 SECURITY DETAILS

53-TY-502 SECURITY DETAILS

53-TY-601 SECURITY SCHEDULES

NO DATE REVISION

BASEMENT

ELEV

E2

TRASH

STORAGE

G17

OUTDOOR

EQUIPMENT

G21

SPRINKLER

ROOM

G20

EMERGENCY

ELECTRICAL

EQUIPMENT

ROOM

G07A

ELEV

E1

TRASH

PICK-UP

G17A

RECEIVING

G23

STAIR

S2

STORAGE

G12

STORAGE

G13

STORAGE

G14

STORAGE

G15

CONFERENCE

ROOM

G08

9'-6" ACT

BREAK

ROOM

G01

8'-0" ACT

SHOWER

G02A

8'-0" GYP

CORRIDOR

G00

9'-0" ACT

EMPLOYEE

LOBBY

G0A 11'-0"

GYP

FREIGHT

E3

MECHANICAL

ROOM

G07

OFFICE

G18

9'-0" ACT

GENERATOR

ROOM

G22

JAN

G19

9'-0" GYP

STORAGE

G16

PUBLIC

MEETING

LOBBY

G09A

9'-0" ACT

DMV

HEARING

G11

9'-6" ACT

STORAGE

G03

7'-6" ACT

MENS

G04

7'-6"-GYP

WOMENS

G05

7'-6"-GYP

PUBLIC

MEETING

ROOM

G09

9'-6" ACT

CLOSET

G10

STAIR

S1

CORRIDOR

G24

9'-0" ACT

STORAGE

G12A

ELECTRICAL

SERVICE

ROOM

G07B

TELEDATA

G06

8'-51/2"-GYP

CORRIDOR

G23A

9'-0" ACT

ELEVATOR

MACHINE

ROOM

G25

9'-0" GYP

STORAGE

G26

9'-0" GYP

7'-6"

GYP

CORRIDOR

G00

9'-0" ACT

7'-0" GYP

967' - 9"

969' - 9"

969' - 9"

969' - 9"

969' - 9"

969' - 9"

969' - 9"

969' - 9"

969' - 9" 969' - 9"

969' - 9"

969' - 9"

969' - 9"

969' - 9"

969' - 9"

969' - 9"

967' - 9"

971' - 3"

969' - 9"

969' - 9"

969' - 9"

R

EF

D

W

UP

UP

UP

UP

UP

UP

DN

UP

A.B.C.D.E.F.G.

LINE OF

FLOOR ABOVE

RAMP

LINE OF

OVERHEAD SHAFT

LINE OF SHAFT

OVERHEAD

INDUSTRIAL RAIL

WI

WI

PI

WI

WI

PI

WI

WI

PI

CR

DL

DC

JB

WL

WL

WL

WL

WL

WL

WL

WL

WL

WL

WL

WL

WL

CR

DLDC

JB

WI

WI

PI

WI

WI

PI

WI

WI

PI

WI

WI

PI

ACP

PS

CR

CRCR

CR

DL

DC DC

JBJBJB

JB

DL

WI

CRCR

DLDL

DC DCJB JB

PS

PS

PS

ACP

CR

FILE:

DRAWN BY:

CHECKED BY:

PROJ. NO:

DRAWING NO:

DRAWING TITLE:

PROJECT NAME:

http://www.ZDSDesign.com

135 Corporate Center Drive Suite 532 Scott Depot, WV 25560

TEL 304/755-0075

FAX 304/755-0076

THIS SQUARE APPEARS 1/2"x1/2"

ON FULL SIZE SHEETS

CLIENT:

XXX

C :\U se rs

\e di so n.

ad ki ns \D oc um en ts

\G

SD

2C

_2

4-

-0 4_

BL

D

G

C

LA

R

KS

BU

R

G _e di so n.

ad ki ns

.rv t

8/

/2

:3 7:

P

M

53-TD-101

ELA

TZ3

GSD-252-C

DEMO PLAN BASEMENT

BUILDING 53 SECURITY

SYSTEM UPGRADES

153 West Main Street Clarksburg, WV 26301

WEST VIRGINIA

GENERAL SERVICES

# KEYNOTES

1 EXISTING PANEL INTERFACE BOARDS (SCHLAGE PIM400-TD2) FOR EXISTING

SCHLAGE AD-400 WIRELESS NETWORK LOCKS TO REMAIN. INTEGRATE EXISTING

WIRELESS LOCKS INTO NEW SYSTEM.

2 READER JUNCTION BOXES FOR ELEVATOR CARD READERS.

3 THIS LOCK NOT WORKING. REPLACE EXISTING LOCK AND INTERFACE WITH NEW

TO MATCH EXISTING. CONNECT TO NEW SYSTEM.

1/8" = 1'-0"53-TD-101

1 DEMO PLAN BASEMENT SECURITY

SYSTEMS DEMOLITION NOTES

1 DISCONNECT AND REMOVE ONLY SYSTEM DEVICES SHOWN TO BE DEMOLISHED.

2 DISCONNECT AND REMOVE ASSOCIATED CONDUIT AND WIRE BACK TO LAST

REMAINING DEVICE. FURNISH AND INSTALL CONDUIT AND WIRE AS NECESSARY

FOR CONTINUITY OF CIRCUIT(S) TO ANY EXISTING DEVICES TO REMAIN.

COORDINATE AND VERIFY REQUIREMENTS WITH NEW WORK IN AREA.

3 FURNISH AND INSTALL CONDUIT AND/OR SYSTEMS WIRING AS NECESSARY FOR

CONTINUITY OF ANY SYSTEMS EQUIPMENT OR DEVICES TO REMAIN. MODIFY OR

REPLACE AS REQUIRED.

4 FURNISH AND INSTALL BLANK COVER PLATES FOR ALL EXISTING UNUSED

OPENINGS.

5 BUILDINGS THAT HAVE CAMERAS THAT WORK OR WOULD WORK IF THE

SOFTWARE AND LICENSES WERE CURRENT SHOULD HAVE NEW NVRS INSTALLED

AND THE EXISTING CAMERAS CONNECTED TO THEM. AS NEW CAMERAS ARE

INSTALLED, REMOVE OLD CAMERAS FROM THE SYSTEM.

6 THE EXISTING ACCESS CONTROL SYSTEM IS TO REMAIN IN USE UNTIL THE NEW

SYSTEM IS COMPLETE. DOORS SHOULD BE MIGRATED TO THE NEW SYSTEM ONE

AT A TIME UNTIL ALL ARE ON THE NEW SYSTEM. DURING THIS MIGRATION, NO

DOOR IS TO REMAIN UNSECURED OR INOPERABLE AT THE END OF A WORKDAY.

WOMEN'S

9'-0" GYP

JAN

9'-0" GYP

ELEV

E1

ELEV

E2

FREIGHT

E3

EMPLOYEE

LOBBY

G0A

10'-0" GYP

STAIR

S2

PLATE /

INVENTORY

ROOM

10'-0" ACT

SUPERVISOR

10'-0" ACT

MANAGER

10'-0" ACT

LEADS (2)

111A

10'-0" ACT

DATA

111B

10'-0" ACT

CONFERENCE

/ TRAINING

10'-0" ACT

BREAK

ROOM

10'-0" ACT

UNISEX

TOILET

(ADA)

9'-0"ACT

UNISEX

TOILET

9'-0" ACT

SERVER

ROOM

9'-0" ACT

DMV

TELLER

9'-0" ACT

AUTOMATED

TESTING

10'-0"

INFO DESK

10'-0"

WORKFORCE

LOBBY

10'-0" ACT

INTERVIEW

10'-0" ACT

OFFICE

9'-0" ACT

CLASSROOM

9'-0" ACT

LARGE

CONFERENCE

9'-0" ACT

SMALL

CONFERENCE

9'-0" ACT

BREAKROOM

10'-0" ACT

OFFICE

10'-0" ACT

SECURITY

100A

DMV

10'-0" ACT

EXAMINATIONS

9'-0"

MEN'S

9'-0" GYP

PHOTO

103A 10'-0"

CHECK

OUT

10'-0" ACT

MAIL

100B

FILE/COPY

9'-0" ACT

RECEPTION

9'-0" ACT

OFFICE

10'-0" ACT

OFFICE

10'-0" ACT

OFFICE

10'-0" ACT

OFFICE

10'-0" ACT

FILE/

STORAGE

9'-0" ACT

FILE/

STORAGE

9'-0" ACT

FILE/

STORAGE

9'-0" ACT

MEETING/

CONFERENCE

10'-0" ACT

UNISEX

TOILET

(ADA)

9'-0" ACT

UNISEX

TOILET

9'-0" ACT

STORAGE

9'-0" ACT

STORAGE

9'-0" GYP

PHOTO

9'-0" ACT

TEL/DATA

9'-0" ACT ELEC

9'-0" ACT

LOBBY

10'-0" ACT

CORRIDOR

106A

9'-0"ACT

CORRIDOR

9'-0" ACT

ELEV

LOBBY

10'-6" ACT

STAIR

S1

INTERVIEW

125J

INTERVIEW

125C

INTERVIEW

125F

INTERVIEW

125D

INTERVIEW

125E

INTERVIEW

125G

INTERVIEW

125H

INTERVIEW

125A

INTERVIEW

125B

DMV

9'-0" ACT

DN

DN

DN

DN

DN

UP

UP

RAILING

RAILING

RAMP

RAILING

1 2 3

CR

CR

DL

DL

DC

DC

JB

JB

WL

WL

WL

WL

WL

WL

WL

WL

CR

DL

DC

DC

JB

PI

WI

WI

CR

DL

DC

JB

PB W

SCPKP

ACP PS

PS PS

4 (E)SNR0025

FILE:

DRAWN BY:

CHECKED BY:

PROJ. NO:

DRAWING NO:

DRAWING TITLE:

PROJECT NAME:

http://www.ZDSDesign.com

135 Corporate Center Drive Suite 532 Scott Depot, WV 25560

TEL 304/755-0075

FAX 304/755-0076

THIS SQUARE APPEARS 1/2"x1/2"

ON FULL SIZE SHEETS

CLIENT:

XXX

C :\U se rs

\e di so n.

ad ki ns \D oc um en ts

\G

SD

2C

_2

4-

-0 4_

BL

D

G

C

LA

R

KS

BU

R

G _e di so n.

ad ki ns

.rv t

8/

/2

:3 7:

P

M

53-TD-102

ELA

TZ3

GSD-252-C

DEMO PLAN FIRST

FLOOR

BUILDING 53 SECURITY

SYSTEM UPGRADES

153 West Main Street Clarksburg, WV 26301

WEST VIRGINIA

GENERAL SERVICES

# KEYNOTES

1 EXISTING PANEL INTERFACE BOARDS (SCHLAGE PIM400-TD2) FOR EXISTING

SCHLAGE AD-400 WIRELESS NETWORK LOCKS TO REMAIN. INTEGRATE EXISTING

WIRELESS LOCKS INTO NEW SYSTEM.

2 EXISTING HONEYWELL SECURITY PANEL AND KEYPAD TO REMAIN. SYSTEM TO

REMAIN INDEPENDENT.

3 WIRELESS PANIC PENDANT TO REMAIN.

4 EXISTING SECURITY RACK. REUSE EXISTING RACK.

5 INSTALL NEW NVR IN RACK AND CONNECT THE EXISTING CAMERAS. AS NEW

CAMERAS ARE INSTALLED, REMOVE OLD CAMERAS FROM THE SYSTEM.

1/8" = 1'-0"53-TD-102

1 DEMO PLAN FIRST FLOOR SECURITY

SYSTEMS DEMOLITION NOTES

1 DISCONNECT AND REMOVE ONLY SYSTEM DEVICES SHOWN TO BE DEMOLISHED.

2 DISCONNECT AND REMOVE ASSOCIATED CONDUIT AND WIRE BACK TO LAST

REMAINING DEVICE. FURNISH AND INSTALL CONDUIT AND WIRE AS NECESSARY

FOR CONTINUITY OF CIRCUIT(S) TO ANY EXISTING DEVICES TO REMAIN.

COORDINATE AND VERIFY REQUIREMENTS WITH NEW WORK IN AREA.

3 FURNISH AND INSTALL CONDUIT AND/OR SYSTEMS WIRING AS NECESSARY FOR

CONTINUITY OF ANY SYSTEMS EQUIPMENT OR DEVICES TO REMAIN. MODIFY OR

REPLACE AS REQUIRED.

4 FURNISH AND INSTALL BLANK COVER PLATES FOR ALL EXISTING UNUSED

OPENINGS.

5 BUILDINGS THAT HAVE CAMERAS THAT WORK OR WOULD WORK IF THE

SOFTWARE AND LICENSES WERE CURRENT SHOULD HAVE NEW NVRS INSTALLED

AND THE EXISTING CAMERAS CONNECTED TO THEM. AS NEW CAMERAS ARE

INSTALLED, REMOVE OLD CAMERAS FROM THE SYSTEM.

6 THE EXISTING ACCESS CONTROL SYSTEM IS TO REMAIN IN USE UNTIL THE NEW

SYSTEM IS COMPLETE. DOORS SHOULD BE MIGRATED TO THE NEW SYSTEM ONE

AT A TIME UNTIL ALL ARE ON THE NEW SYSTEM. DURING THIS MIGRATION, NO

OFFICE

9'-0" ACT

OFFICE

9'-0" ACT

OFFICE

9'-0" ACT

OFFICE

9'-0" ACT

TELEDATA

9'-0" ACT

OFFICE

9'-0" ACT

OFFICE

9'-0" ACT

INTERVIEW

9'-0" ACT

INTERVIEW

9'-0" ACT

INTERVIEW

9'-0" ACT

OFFICE

9'-0" ACT

OFFICE

OFFICE

OFFICE

CSM

OFFICE

9'-0" ACT

INTERVIEW

9'-0" ACT

INTERVIEW

9'-0" ACT

INTERVIEW

9'-0" ACT

FILE

10'-0" ACT

WORK

STATIONS

10'-0"

OPEN OFFICE

WORKSTATIONS

10'-0" ACT

DHHR

LOBBY

10"-0" ACT

WORK

STATIONS

10'-0" ACT

CORRIDOR

10'-0" ACT

FAMILY

VISITATION

10'-0" ACT

MDT

CONFERENCE

ROOM

VIDEO

9'-0" ACT

UNISEX

TOILET

9'-0" ACT

RECEPTION

9'-0" ACT

OFFICE

9'-0" ACT

INTERVIEW

9'-0" ACT

INTERVIEW

9'-0" ACT

INTERVIEW

9'-0" ACT

OFFICE

9'-0" ACT

COPIER

9'-0" ACT

OFFICE

9'-0" ACT

BREAK

ROOM

10'-0" ACT

INTERVIEW

10'-0" ACT

MEN'S

9'-0" GYP

WOMEN'S

9'-0" GYP

OFFICE

9'-0" ACT

JAN

9'-0" GYP

ELEC

9'-0" ACT

CORRIDOR

9'-0" ACT

CORRIDOR

9'-0" ACT

CORRIDOR

9'-0" ACT

STAIR

S1

TOILET

9'-0" ACT

ELEV

E1

ELEV

E2

OFFICE

UNISEX

TOILET

9'-0" ACT

9'-0" ACT

OFFICE

9'-0" ACT

9'-0" ACT

OFFICE

9'-0" ACT

CORRIDOR

10'-0" ACT

CORRIDOR

9'-0" ACT

INTERVIEW

9'-0" ACT

OFFICE

9'-0" ACT

FREIGHT

E3

CORRIDOR

9'-0" ACT

WORK

STATIONS

9'-0"

9'-0" ACT

9'-0" ACT

WORK

STATIONS

10'-0"

WORK

STATIONS

9'-0"

DHHR

LOBBY

10"-0" ACT

DHS CASEWORK

AREA

CHILD

PROTECTIVE

SERVICES

UP

DN

UP

DN

CR

DL

DC

JB

WL

WL

WI

WI

PI

WI

WI

PI

WI

WI

PI

WL

WL

WL

WL

WL

WL

WL

WL

CR

DL

DC

JB

CRCR

CR

CR

DL

DL

DC

DC

JB JB

JB JB

WL

PIPIPIPI

WI

WI

WI

WI

WI

WI

WI

WI

CR

CR

CR

CR

DL

DL DC

JBJB

JB JB

ACP ACP

PS PS

PS PSPS

PS

WL

WL

RECEPTION

FILE:

DRAWN BY:

CHECKED BY:

PROJ. NO:

DRAWING NO:

DRAWING TITLE:

PROJECT NAME:

http://www.ZDSDesign.com

135 Corporate Center Drive Suite 532 Scott Depot, WV 25560

TEL 304/755-0075

FAX 304/755-0076

THIS SQUARE APPEARS 1/2"x1/2"

ON FULL SIZE SHEETS

CLIENT:

XXX

C :\U se rs

\e di so n.

ad ki ns \D oc um en ts

\G

SD

2C

_2

4-

-0 4_

BL

D

G

C

LA

R

KS

BU

R

G _e di so n.

ad ki ns

.rv t

8/

/2

:3 7:

P

M

53-TD-103

ELA

TZ3

GSD-252-C

DEMO PLAN SECOND

FLOOR

BUILDING 53 SECURITY

SYSTEM UPGRADES

153 West Main Street Clarksburg, WV 26301

WEST VIRGINIA

GENERAL SERVICES

# KEYNOTES

1 EXISTING PANEL INTERFACE BOARDS (SCHLAGE PIM400-TD2) FOR EXISTING

SCHLAGE AD-400 WIRELESS NETWORK LOCKS TO REMAIN. INTEGRATE EXISTING

WIRELESS LOCKS INTO NEW SYSTEM.

2 REMOVE WIRELESS LOCKSET AND REPLACE WITH MECHANICAL LOCKSET

(SCHLAGE ND80 LEVER SET, RHODES STYLE LEVERS, SATIN CHROME FINISH,

PRIMUS XP CYLINDER). FIELD VERIFY LOCKSET REQUIREMENTS.

1/8" = 1'-0"53-TD-103

1 DEMO PLAN SECOND FLOOR SECURITY

SYSTEMS DEMOLITION NOTES

1 DISCONNECT AND REMOVE ONLY SYSTEM DEVICES SHOWN TO BE DEMOLISHED.

2 DISCONNECT AND REMOVE ASSOCIATED CONDUIT AND WIRE BACK TO LAST

REMAINING DEVICE. FURNISH AND INSTALL CONDUIT AND WIRE AS NECESSARY

FOR CONTINUITY OF CIRCUIT(S) TO ANY EXISTING DEVICES TO REMAIN.

COORDINATE AND VERIFY REQUIREMENTS WITH NEW WORK IN AREA.

3 FURNISH AND INSTALL CONDUIT AND/OR SYSTEMS WIRING AS NECESSARY FOR

CONTINUITY OF ANY SYSTEMS EQUIPMENT OR DEVICES TO REMAIN. MODIFY OR

REPLACE AS REQUIRED.

4 FURNISH AND INSTALL BLANK COVER PLATES FOR ALL EXISTING UNUSED

OPENINGS.

5 BUILDINGS THAT HAVE CAMERAS THAT WORK OR WOULD WORK IF THE

SOFTWARE AND LICENSES WERE CURRENT SHOULD HAVE NEW NVRS INSTALLED

AND THE EXISTING CAMERAS CONNECTED TO THEM. AS NEW CAMERAS ARE

INSTALLED, REMOVE OLD CAMERAS FROM THE SYSTEM.

6 THE EXISTING ACCESS CONTROL SYSTEM IS TO REMAIN IN USE UNTIL THE NEW

SYSTEM IS COMPLETE. DOORS SHOULD BE MIGRATED TO THE NEW SYSTEM ONE

AT A TIME UNTIL ALL ARE ON THE NEW SYSTEM. DURING THIS MIGRATION, NO

TRAINING

ROOM

TRAINING

ROOM

CONFERENCE

ROOM

CLOSET

OFFICE

OFFICE

OFFICE

SMALL

COMPUTER

TRAINING

ROOM305

WOMEN'S

DHHR

TRAINING

LOBBY

OFFICE

9'-0" ACT

MEN'S

OFFICE

9'-0" ACT

TRAINING

ROOM

TRAINING

ROOM

TRAINING

ROOM

TELEDATA

JAN

CORRIDOR

WORK

STATIONS

OFFICE

CLOSET

316A

COPIER

318A

TRAINING

ROOM

BREAK

ROOM

10'-0" ACT

CORRIDOR

CORRIDOR

STAIR

S1

ELEV

E1

ELEV

E2

CORRIDOR

CONFERENCE

ROOM

OFFICE

CONFERENCE

FILE

OFFICE

OFFICE

BREAK

ROOM

OFFICE

OFFICE

FILE

9'-0" ACT

OFFICE

OFFICE

OFFICE

OFFICE

COPY

339A

RECEPTION

RECEPTION

CONFERENCE

10'-0" ACT

BREAK

ROOM

9'-0" ACT

CONFERENCE

AUDITOR

LOBBY

STATE

TAX

LOBBY

FREIGHT

E3

STORAGE

322A

ELEC

SECRETARY OF

STATE

WORK

STATIONS

CORRIDOR

3RD

FLOOR

LOBBY

CORRIDOR

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT 9'-0" ACT

10'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

10'-0" ACT

10'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" GYP

9'-0" GYP

9'-0" GYP

10'-0" ACT

10'-0" ACT

9'-0" ACT

9'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT 9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" GYP

9'-0" GYP

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

9'-0" ACT

VETERANS

SERVICES

UP

DN

UP

DN

JB

CR

DL

DC

WL

WL

WL

WL

WL

WL

WL

WL

WL

WL

WL

CR

DL

DC

JB

ACP

PIPIPIPI

WI

WI

WI

WI

WI

WI

WI

WI

WI

WI

WI

WI

PI

PI

PS

PS

WL

FILE:

DRAWN BY:

CHECKED BY:

PROJ. NO:

DRAWING NO:

DRAWING TITLE:

PROJECT NAME:

http://www.ZDSDesign.com

135 Corporate Center Drive Suite 532 Scott Depot, WV 25560

TEL 304/755-0075

FAX 304/755-0076

THIS SQUARE APPEARS 1/2"x1/2"

ON FULL SIZE SHEETS

CLIENT:

XXX

C :\U se rs

\e di so n.

ad ki ns \D oc um en ts

\G

SD

2C

_2

4-

-0 4_

BL

D

G

C

LA

R

KS

BU

R

G _e di so n.

ad ki ns

.rv t

8/

/2

:3 7:

P

M

53-TD-104

ELA

TZ3

GSD-252-C

DEMO PLAN THIRD

FLOOR

BUILDING 53 SECURITY

SYSTEM UPGRADES

153 West Main Street Clarksburg, WV 26301

WEST VIRGINIA

GENERAL SERVICES

# KEYNOTES

1 EXISTING PANEL INTERFACE BOARDS (SCHLAGE PIM400-TD2) FOR EXISTING

SCHLAGE AD-400 WIRELESS NETWORK LOCKS TO REMAIN. INTEGRATE EXISTING

WIRELESS LOCKS INTO NEW SYSTEM.

1/8" = 1'-0"53-TD-104

1 DEMO PLAN THIRD FLOOR SECURITY

SYSTEMS DEMOLITION NOTES

1 DISCONNECT AND REMOVE ONLY SYSTEM DEVICES SHOWN TO BE DEMOLISHED.

2 DISCONNECT AND REMOVE ASSOCIATED CONDUIT AND WIRE BACK TO LAST

REMAINING DEVICE. FURNISH AND INSTALL CONDUIT AND WIRE AS NECESSARY

FOR CONTINUITY OF CIRCUIT(S) TO ANY EXISTING DEVICES TO REMAIN.

COORDINATE AND VERIFY REQUIREMENTS WITH NEW WORK IN AREA.

3 FURNISH AND INSTALL CONDUIT AND/OR SYSTEMS WIRING AS NECESSARY FOR

CONTINUITY OF ANY SYSTEMS EQUIPMENT OR DEVICES TO REMAIN. MODIFY OR

REPLACE AS REQUIRED.

4 FURNISH AND INSTALL BLANK COVER PLATES FOR ALL EXISTING UNUSED

OPENINGS.

5 BUILDINGS THAT HAVE CAMERAS THAT WORK OR WOULD WORK IF THE

SOFTWARE AND LICENSES WERE CURRENT SHOULD HAVE NEW NVRS INSTALLED

AND THE EXISTING CAMERAS CONNECTED TO THEM. AS NEW CAMERAS ARE

INSTALLED, REMOVE OLD CAMERAS FROM THE SYSTEM.

6 THE EXISTING ACCESS CONTROL SYSTEM IS TO REMAIN IN USE UNTIL THE NEW

SYSTEM IS COMPLETE. DOORS SHOULD BE MIGRATED TO THE NEW SYSTEM ONE

AT A TIME UNTIL ALL ARE ON THE NEW SYSTEM. DURING THIS MIGRATION, NO

MEN'S

STAIR

S1

ELEV

E1

ELEV

E2

CORRIDOR

JANITOR

CONFERENCE/TRAINING

STORAGE

OFFICE

OFFICE

OFFICE

TOILET

OFFICE

TOILET

MAIL

406A

BREAK

ROOM

OFFICE

OFFICE

OFFICE

REHAB

LOBBY

OFFICE

TEL/DATA

OFFICE

OFFICE

FILE

RECEPTION

FREIGHT

E3

OFFICE

ELEC

CORRIDOR

CORRIDOR

STAIR

S2

RESERVE

CONFERENCE

ROOM

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

KITCHEN

OFFICE

OFFICE

OFFICE

OFFICE

UNASSIGNED

ROOM

CHILD SUPPORT

SERVICES

UNASSIGNED

ROOM

AUDITOR

OFFICE

UNASSIGNED

UNASSIGNED

UNASSIGNED

UNASSIGNED

OFFICE

OFFICE

425 OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

COPIER

421A

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT 10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

9'-0" ACT

9'-0" GYP

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

9'-0" ACT

9'-0" GYP 9'-0" GYP

9'-0" GYP

9'-0" GYP

9'-0" GYP

RESERVE

CONFERENCE

ROOM

10'-0" ACT

GYP BARREL CEILING

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT 10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT 10'-0" ACT

10'-0" ACT 10'-0" ACT

10'-0" ACT 10'-0" ACT

10'-0" ACT

DL

DC CR

JB WL

WL

WL

WI

WI PI

WI

WI PI

WI

WI PI

WI

WI PI

WI

WI PI

WL WL

WL

ACP

WI

WI PI

CR

DL

DC

JB

PS

PSPS

PS

WL

WL

W L

W L 1

FILE:

DRAWN BY:

CHECKED BY:

PROJ. NO:

DRAWING NO:

DRAWING TITLE:

PROJECT NAME:

http://www.ZDSDesign.com

135 Corporate Center Drive Suite 532 Scott Depot, WV 25560

TEL 304/755-0075

FAX 304/755-0076

THIS SQUARE APPEARS 1/2"x1/2"

ON FULL SIZE SHEETS

CLIENT:

XXX

C :\U se rs

\e di so n.

ad ki ns \D oc um en ts

\G

SD

2C

_2

4-

-0 4_

BL

D

G

C

LA

R

KS

BU

R

G _e di so n.

ad ki ns

.rv t

8/

/2

:3 7:

P

M

53-TD-105

ELA

TZ3

GSD-252-C

DEMO PLAN FOURTH

FLOOR

BUILDING 53 SECURITY

SYSTEM UPGRADES

153 West Main Street Clarksburg, WV 26301

WEST VIRGINIA

GENERAL SERVICES

# KEYNOTES

1 EXISTING PANEL INTERFACE BOARDS (SCHLAGE PIM400-TD2) FOR EXISTING

SCHLAGE AD-400 WIRELESS NETWORK LOCKS TO REMAIN. INTEGRATE EXISTING

WIRELESS LOCKS INTO NEW SYSTEM.

1/8" = 1'-0"53-TD-105

1 DEMO PLAN FOURTH FLOOR SECURITY

SYSTEMS DEMOLITION NOTES

1 DISCONNECT AND REMOVE ONLY SYSTEM DEVICES SHOWN TO BE DEMOLISHED.

2 DISCONNECT AND REMOVE ASSOCIATED CONDUIT AND WIRE BACK TO LAST

REMAINING DEVICE. FURNISH AND INSTALL CONDUIT AND WIRE AS NECESSARY

FOR CONTINUITY OF CIRCUIT(S) TO ANY EXISTING DEVICES TO REMAIN.

COORDINATE AND VERIFY REQUIREMENTS WITH NEW WORK IN AREA.

3 FURNISH AND INSTALL CONDUIT AND/OR SYSTEMS WIRING AS NECESSARY FOR

CONTINUITY OF ANY SYSTEMS EQUIPMENT OR DEVICES TO REMAIN. MODIFY OR

REPLACE AS REQUIRED.

4 FURNISH AND INSTALL BLANK COVER PLATES FOR ALL EXISTING UNUSED

OPENINGS.

5 BUILDINGS THAT HAVE CAMERAS THAT WORK OR WOULD WORK IF THE

SOFTWARE AND LICENSES WERE CURRENT SHOULD HAVE NEW NVRS INSTALLED

AND THE EXISTING CAMERAS CONNECTED TO THEM. AS NEW CAMERAS ARE

INSTALLED, REMOVE OLD CAMERAS FROM THE SYSTEM.

6 THE EXISTING ACCESS CONTROL SYSTEM IS TO REMAIN IN USE UNTIL THE NEW

SYSTEM IS COMPLETE. DOORS SHOULD BE MIGRATED TO THE NEW SYSTEM ONE

AT A TIME UNTIL ALL ARE ON THE NEW SYSTEM. DURING THIS MIGRATION, NO

5'-3 1/4"

5' -3

/4

DN

DN

R.D. O.F.

R.D. O.F.

R.D.

R.D. O.F.

ROOF CANT

ROOF CANT

ROOF CANT

ROOF CANT

TRASH CHUTE

O.F.

24X18 ELEVATOR LOUVER

ROOFTOP SHAFT LOUVER

ROOFTOP SHAFT LOUVER

SLOPE

SLOPE

DL DC

CRJB

DLDC

CRJB

STAIR PRESSURIZATION

FAN SPF-2

STAIR PRESSURIZATION

FAN SPF-1

FILE:

DRAWN BY:

CHECKED BY:

PROJ. NO:

DRAWING NO:

DRAWING TITLE:

PROJECT NAME:

http://www.ZDSDesign.com

135 Corporate Center Drive Suite 532 Scott Depot, WV 25560

TEL 304/755-0075

FAX 304/755-0076

THIS SQUARE APPEARS 1/2"x1/2"

ON FULL SIZE SHEETS

CLIENT:

XXX

C :\U se rs

\e di so n.

ad ki ns \D oc um en ts

\G

SD

2C

_2

4-

-0 4_

BL

D

G

C

LA

R

KS

BU

R

G _e di so n.

ad ki ns

.rv t

8/

/2

:3 7:

P

M

53-TD-106

ELA

TZ3

GSD-252-C

DEMO PLAN ROOF

BUILDING 53 SECURITY

SYSTEM UPGRADES

153 West Main Street Clarksburg, WV 26301

WEST VIRGINIA

GENERAL SERVICES

# KEYNOTES

1/8" = 1'-0"53-TD-106

1 DEMO PLAN ROOF SECURITY

SYSTEMS DEMOLITION NOTES

1 DISCONNECT AND REMOVE ONLY SYSTEM DEVICES SHOWN TO BE DEMOLISHED.

2 DISCONNECT AND REMOVE ASSOCIATED CONDUIT AND WIRE BACK TO LAST

REMAINING DEVICE. FURNISH AND INSTALL CONDUIT AND WIRE AS NECESSARY

FOR CONTINUITY OF CIRCUIT(S) TO ANY EXISTING DEVICES TO REMAIN.

COORDINATE AND VERIFY REQUIREMENTS WITH NEW WORK IN AREA.

3 FURNISH AND INSTALL CONDUIT AND/OR SYSTEMS WIRING AS NECESSARY FOR

CONTINUITY OF ANY SYSTEMS EQUIPMENT OR DEVICES TO REMAIN. MODIFY OR

REPLACE AS REQUIRED.

4 FURNISH AND INSTALL BLANK COVER PLATES FOR ALL EXISTING UNUSED

OPENINGS.

5 BUILDINGS THAT HAVE CAMERAS THAT WORK OR WOULD WORK IF THE

SOFTWARE AND LICENSES WERE CURRENT SHOULD HAVE NEW NVRS INSTALLED

AND THE EXISTING CAMERAS CONNECTED TO THEM. AS NEW CAMERAS ARE

INSTALLED, REMOVE OLD CAMERAS FROM THE SYSTEM.

6 THE EXISTING ACCESS CONTROL SYSTEM IS TO REMAIN IN USE UNTIL THE NEW

SYSTEM IS COMPLETE. DOORS SHOULD BE MIGRATED TO THE NEW SYSTEM ONE

AT A TIME UNTIL ALL ARE ON THE NEW SYSTEM. DURING THIS MIGRATION, NO

GUY

TEL.

MANHOLE

DN

DN

SECURED STATE

VEHICLE PARKING

LP LPLP

LP

LP

LP

LP

LP

LP

LP

FMB

FMB

FMB

FILE:

DRAWN BY:

CHECKED BY:

PROJ. NO:

DRAWING NO:

DRAWING TITLE:

PROJECT NAME:

http://www.ZDSDesign.com

135 Corporate Center Drive Suite 532 Scott Depot, WV 25560

TEL 304/755-0075

FAX 304/755-0076

THIS SQUARE APPEARS 1/2"x1/2"

ON FULL SIZE SHEETS

CLIENT:

XXX

C :\U se rs

\e di so n.

ad ki ns \D oc um en ts

\G

SD

2C

_2

4-

-0 4_

BL

D

G

C

LA

R

KS

BU

R

G _e di so n.

ad ki ns

.rv t

8/

/2

:3 7:

P

M

53-TD-107

ELA

TZ3

GSD-252-C

DEMO PLAN SITE

BUILDING 53 SECURITY

SYSTEM UPGRADES

153 West Main Street Clarksburg, WV 26301

WEST VIRGINIA

GENERAL SERVICES

# KEYNOTES

1 REMOVE EXISTING CAMERAS AND MOUNTS.

1/16" = 1'-0"53-TD-107

1 DEMO PLAN SITE SECURITY

SYSTEMS DEMOLITION NOTES

1 DISCONNECT AND REMOVE ONLY SYSTEM DEVICES SHOWN TO BE DEMOLISHED.

2 DISCONNECT AND REMOVE ASSOCIATED CONDUIT AND WIRE BACK TO LAST

REMAINING DEVICE. FURNISH AND INSTALL CONDUIT AND WIRE AS NECESSARY

FOR CONTINUITY OF CIRCUIT(S) TO ANY EXISTING DEVICES TO REMAIN.

COORDINATE AND VERIFY REQUIREMENTS WITH NEW WORK IN AREA.

3 FURNISH AND INSTALL CONDUIT AND/OR SYSTEMS WIRING AS NECESSARY FOR

CONTINUITY OF ANY SYSTEMS EQUIPMENT OR DEVICES TO REMAIN. MODIFY OR

REPLACE AS REQUIRED.

4 FURNISH AND INSTALL BLANK COVER PLATES FOR ALL EXISTING UNUSED

OPENINGS.

5 BUILDINGS THAT HAVE CAMERAS THAT WORK OR WOULD WORK IF THE

SOFTWARE AND LICENSES WERE CURRENT SHOULD HAVE NEW NVRS INSTALLED

AND THE EXISTING CAMERAS CONNECTED TO THEM. AS NEW CAMERAS ARE

INSTALLED, REMOVE OLD CAMERAS FROM THE SYSTEM.

6 THE EXISTING ACCESS CONTROL SYSTEM IS TO REMAIN IN USE UNTIL THE NEW

SYSTEM IS COMPLETE. DOORS SHOULD BE MIGRATED TO THE NEW SYSTEM ONE

AT A TIME UNTIL ALL ARE ON THE NEW SYSTEM. DURING THIS MIGRATION, NO

BASEMENT

ELEV

E2

TRASH

STORAGE

G17

OUTDOOR

EQUIPMENT

G21

SPRINKLER

ROOM

G20

EMERGENCY

ELECTRICAL

EQUIPMENT

ROOM

G07A

ELEV

E1

TRASH

PICK-UP

G17A

RECEIVING

G23

STAIR

S2

STORAGE

G12

STORAGE

G13

STORAGE

G14

STORAGE

G15

CONFERENCE

ROOM

G08

9'-6" ACT

BREAK

ROOM

G01

8'-0" ACT

SHOWER

G02A

8'-0" GYP

CORRIDOR

G00

9'-0" ACT

EMPLOYEE

LOBBY

G0A 11'-0"

GYP

FREIGHT

E3

MECHANICAL

ROOM

G07

OFFICE

G18

9'-0" ACT

GENERATOR

ROOM

G22

JAN

G19

9'-0" GYP

STORAGE

G16

PUBLIC

MEETING

LOBBY

G09A

9'-0" ACT

DMV

HEARING

G11

9'-6" ACT

STORAGE

G03

7'-6" ACT

MENS

G04

7'-6"-GYP

WOMENS

G05

7'-6"-GYP

PUBLIC

MEETING

ROOM

G09

9'-6" ACT

CLOSET

G10

STAIR

S1

CORRIDOR

G24

9'-0" ACT

STORAGE

G12A

ELECTRICAL

SERVICE

ROOM

G07B

TELEDATA

G06

8'-51/2"-GYP

CORRIDOR

G23A

9'-0" ACT

ELEVATOR

MACHINE

ROOM

G25

9'-0" GYP

STORAGE

G26

9'-0" GYP

7'-6"

GYP

CORRIDOR

G00

9'-0" ACT

7'-0" GYP

967' - 9"

969' - 9"

969' - 9"

969' - 9"

969' - 9"

969' - 9"

969' - 9"

969' - 9"

969' - 9" 969' - 9"

969' - 9"

969' - 9"

969' - 9"

969' - 9"

969' - 9"

969' - 9"

967' - 9"

971' - 3"

969' - 9"

969' - 9"

969' - 9"

R

EF

D

W

UP

UP

UP

UP

UP

UP

DN

UP

A.B.C.D.E.F.G.

LINE OF

FLOOR ABOVE

RAMP

LINE OF

OVERHEAD SHAFT

LINE OF SHAFT

OVERHEAD

INDUSTRIAL RAIL

PI

PI

PI

DL

JB

WL

WL

WL

WL

WL

WL

WL

WL

WL

WL

WL

WL

DL

JB

PI

PI

PI

PI

DL

JB

DL

DLDL

JB JB

CR

CR

CR

CR

CR CR

CR

DC

DC

DCDC

DC DC

CR

ACP ACP WL

CR

ACP

DC

DC

C001

TYPE B

C003

TYPE B

C015

TYPE A

DC002

C004

TYPE B

DC005

(E)PI005

(E)PI006

(E)PI007

CR001

(E)DL001DC001

(E)PI004

(E)PI003

(E)PI002

(E)PI001

(E)WL007

(E)WL004

(E)WL005

(E)WL006

(E)WL008

WL001

ACP001 ACP002

SNR001

DC003

(E)DL002

CR005

CR003

CR004

CR002

ACP008

(E)WL009

(E)WL013

DC004

CR006

(E)DL003

DC005

(E)DL004

CR007

(E)WL010

(E)WL011

(E)DL005

DC006

CR008 (E)WL012

(E)WL003

(E)WL002

(E)DL022

CR029

DC026

DC025

FILE:

DRAWN BY:

CHECKED BY:

PROJ. NO:

DRAWING NO:

DRAWING TITLE:

PROJECT NAME:

http://www.ZDSDesign.com

135 Corporate Center Drive Suite 532 Scott Depot, WV 25560

TEL 304/755-0075

FAX 304/755-0076

THIS SQUARE APPEARS 1/2"x1/2"

ON FULL SIZE SHEETS

CLIENT:

XXX

C :\U se rs

\e di so n.

ad ki ns \D oc um en ts

\G

SD

2C

_2

4-

-0 4_

BL

D

G

C

LA

R

KS

BU

R

G _e di so n.

ad ki ns

.rv t

8/

/2

:3 7:

P

M

53-TY-101

ELA

TZ3

GSD-252-C

BASEMENT SECURITY

PLAN

BUILDING 53 SECURITY

SYSTEM UPGRADES

153 West Main Street Clarksburg, WV 26301

WEST VIRGINIA

GENERAL SERVICES

1/8" = 1'-0"53-TY-101

1 PROPOSED BASEMENT SECURITY PLAN

KEYNOTES

1 ACCESS CONTROL PANEL FOR IN-CAB CARD READERS. PROVIDE OUTPUTS FOR

ALL FLOORS SERVED BY THE ELEVATORS. ACCESS SHALL BE CONTROLLABLE BY

THE INDIVIDUAL FLOOR. CURRENT CONFIGURATION LIMITS ACCESS TO THE

BASEMENT WITHOUT A VALID CREDENTIAL.

2 THIS LOCK NOT WORKING. REPLACE EXISTING LOCK AND INTERFACE WITH NEW

TO MATCH EXISTING. CONNECT TO NEW SYSTEM.

3 IN-CAB CARD READER. CURRENT CONFIGURATION LIMITS ACCESS TO THE

BASEMENT WITHOUT A VALID CREDENTIAL.

5 EXISTING PANEL INTERFACE BOARDS (SCHLAGE PIM400-TD2) FOR EXISTING

SCHLAGE AD-400 WIRELESS NETWORK LOCKS TO REMAIN. INTEGRATE EXISTING

WIRELESS LOCKS INTO NEW SYSTEM.

6 NEW SECURITY NETWORK RACK. PROVIDE 12 STRAND MM OM4 ARMOURED FIBER

TO SNR002. TERMINATE FIBER IN FIBER TERMINATION PANEL AT BOTH ENDS. SEE

SPECIFICATIONS AND DETAIL 1 ON SHEET 53-TY-501.

7 PROVIDE TWO 120V, 20A CIRCUITS FOR NEW SECURITY NETWORK RACK. CIRCUIT

TO NEAREST ELECTRICAL PANEL.

SECURITY SYSTEM SHEET NOTES

A SEE DETAIL SHEET FOR SECURITY CAMERA MOUNTING

B SEE SECURITY DEVICE SCHEDULE FOR ADDITIONAL INFORMATION

C ALL COMMUNICATION CABLES SHALL BE INSTALLED IN CONDUIT, CABLE TRAY, OR

SUPPORTED BY CABLE HOOKS. PROVIDE BUSHINGS AT THE ENDS OF ALL

CONDUITS WHERE STUBBED ABOVE ACCESSIBLE CEILINGS OR WHERE DROPPED

INTO CABLE TRAYS. PROVIDE CABLE HOOKS ABOVE ACCESSIBLE CEILINGS FOR

CABLE INSTALLATION WHERE NOT INSTALLED IN A CONDUIT OR CABLE TRAY.

D BUILDINGS THAT HAVE CAMERAS THAT WORK OR WOULD WORK IF THE

SOFTWARE AND LICENSES WERE CURRENT SHOULD HAVE NEW NVRS INSTALLED

AND THE EXISTING CAMERAS CONNECTED TO THEM. AS NEW CAMERAS ARE

INSTALLED, REMOVE OLD CAMERAS FROM THE SYSTEM.

E ALL CABLES AND DEVICES TO BE LABELED. SEE SPECIFICATION AND DETAILS

FOR SPECIFIC REQUIREMENTS.

F THE EXISTING ACCESS CONTROL SYSTEM IS TO REMAIN IN USE UNTIL THE NEW

SYSTEM IS COMPLETE. DOORS SHOULD BE MIGRATED TO THE NEW SYSTEM ONE

AT A TIME UNTIL ALL ARE ON THE NEW SYSTEM. DURING THIS MIGRATION, NO

DOOR IS TO REMAIN UNSECURED OR INOPERABLE AT THE END OF A WORKDAY.

G PROVIDE SURGE PROTECTION FOR ALL EXTERIOR CAMERAS.

9'-0" GYP

JAN

9'-0" GYP

ELEV

E1

ELEV

E2

FREIGHT

E3

EMPLOYEE

LOBBY

G0A

10'-0" GYP

STAIR

S2

PLATE /

INVENTORY

ROOM

10'-0" ACT

SUPERVISOR

10'-0" ACT

MANAGER

10'-0" ACT

LEADS (2)

111A

10'-0" ACT

DATA

111B

10'-0" ACT

CONFERENCE

/ TRAINING

10'-0" ACT

BREAK

ROOM

10'-0" ACT

UNISEX

TOILET

(ADA)

9'-0"ACT

UNISEX

TOILET

9'-0" ACT

SERVER

ROOM

9'-0" ACT

DMV

TELLER

9'-0" ACT

AUTOMATED

TESTING

10'-0"

INFO DESK

10'-0"

WORKFORCE

LOBBY

10'-0" ACT

INTERVIEW

10'-0" ACT

OFFICE

9'-0" ACT

CLASSROOM

9'-0" ACT

LARGE

CONFERENCE

9'-0" ACT

SMALL

CONFERENCE

9'-0" ACT

BREAKROOM

10'-0" ACT

OFFICE

10'-0" ACT

SECURITY

100A

DMV

10'-0" ACT

EXAMINATIONS

9'-0"

MEN'S

9'-0" GYP

PHOTO

103A 10'-0"

CHECK

OUT

10'-0" ACT

MAIL

100B

FILE/COPY

9'-0" ACT

RECEPTION

9'-0" ACT

OFFICE

10'-0" ACT

OFFICE

10'-0" ACT

OFFICE

10'-0" ACT

OFFICE

10'-0" ACT

FILE/

STORAGE

9'-0" ACT

FILE/

STORAGE

9'-0" ACT

FILE/

STORAGE

9'-0" ACT

MEETING/

CONFERENCE

10'-0" ACT

UNISEX

TOILET

(ADA)

9'-0" ACT

UNISEX

TOILET

9'-0" ACT

STORAGE

9'-0" ACT

STORAGE

9'-0" GYP

PHOTO

9'-0" ACT

TEL/DATA

9'-0" ACT ELEC

9'-0" ACT

LOBBY

10'-0" ACT

CORRIDOR

106A

9'-0"ACT

CORRIDOR

9'-0" ACT

ELEV

LOBBY

10'-6" ACT

STAIR

S1

INTERVIEW

125J

INTERVIEW

125C

INTERVIEW

125F

INTERVIEW

125D

INTERVIEW

125E

INTERVIEW

125G

INTERVIEW

125H

INTERVIEW

125A

INTERVIEW

125B

DMV

9'-0" ACT

DN

DN

DN

DN

DN

UP

UP

RAILING

RAILING

RAMP

RAILING

1 2 3

DL

DL

JB

JB

WL

WL

WL

WL

WL

WL

WL

WL

DL

JB

PI

DL JB

PB W

SCPKP

DC

DC CR

ACP

SWKSMO

N

CR

DC

CR

CR

DC

DC

DC MON MON

CWKS 2

C013

TYPE C

DC007

DC008 CR009

C005

TYPE C

C006

TYPE C

C008

TYPE C

C007

TYPE C

C011

TYPE C

C010

TYPE C

C009

TYPE A

DC009

CR010

DC010

C012

TYPE A

CR012 DC012

DC011

CR011

(E)DL006

(E)DL007

(E)DL008

(E)DL009

(E)PI008

(E)WL014

(E)WL017

SWKS01M001

(E)WL018

(E)WL021

(E)WL020

(E)WL019

(E)WL016

ACP003

M002

(E)SNR002

M003

CWKS01

(E)WL015

FILE:

DRAWN BY:

CHECKED BY:

PROJ. NO:

DRAWING NO:

DRAWING TITLE:

PROJECT NAME:

http://www.ZDSDesign.com

135 Corporate Center Drive Suite 532 Scott Depot, WV 25560

TEL 304/755-0075

FAX 304/755-0076

THIS SQUARE APPEARS 1/2"x1/2"

ON FULL SIZE SHEETS

CLIENT:

XXX

C :\U se rs

\e di so n.

ad ki ns \D oc um en ts

\G

SD

2C

_2

4-

-0 4_

BL

D

G

C

LA

R

KS

BU

R

G _e di so n.

ad ki ns

.rv t

8/

/2

:3 7:

P

M

53-TY-102

ELA

TZ3

GSD-252-C

FIRST FLOOR SECURITY

PLAN

BUILDING 53 SECURITY

SYSTEM UPGRADES

153 West Main Street Clarksburg, WV 26301

WEST VIRGINIA

GENERAL SERVICES

1/8" = 1'-0"53-TY-102

1 PROPOSED FIRST FLOOR SECURITY PLAN

KEYNOTES

1 EXISTING HONEYWELL SECURITY PANEL AND KEYPAD TO REMAIN. SYSTEM TO

REMAIN INDEPENDENT.

2 WIRELESS PANIC PENDANT INSTALLED BY DMVTO REMAIN.

3 EXISTING PANEL INTERFACE BOARDS (SCHLAGE PIM400-TD2) FOR EXISTING

SCHLAGE AD-400 WIRELESS NETWORK LOCKS TO REMAIN. INTEGRATE EXISTING

WIRELESS LOCKS INTO NEW SYSTEM.

4 EXISTING SECURITY NETWORK RACK TO BE REUSED. REMOVE ALL UNUSED

EQUIPMENT. PROVIDE 12 STRAND MM OM4 ARMOURED FIBER TO SNR001 AND

SNR003. TERMINATE FIBER IN FIBER TERMINATION PANEL AT BOTH ENDS. SEE

SPECIFICATIONS AND DETAIL 1 ON SHEET 53-TY-501.

5 ADD DELAYED EGRESS HARDWARE TO THIS DOOR.

6 INTERLOCK DOOR OPERATOR BUTTONS WITH ACCESS CONTROL SYSTEM. SEE

DETAIL ON SHEET 53-TY-501.

7 PROVIDE 3 - 34" MONITORS FOR SECURITY WORKSTATION

8 PROVIDE TWO 120V, 20A CIRCUITS FOR NEW SECURITY NETWORK RACK. CIRCUIT

TO NEAREST ELECTRICAL PANEL.

9 CREDENTIALING WORKSTATION. COORDINATE EXACT LOCATION WITH OWNER.

SECURITY SYSTEM SHEET NOTES

A SEE DETAIL SHEET FOR SECURITY CAMERA MOUNTING

B SEE SECURITY DEVICE SCHEDULE FOR ADDITIONAL INFORMATION

C ALL COMMUNICATION CABLES SHALL BE INSTALLED IN CONDUIT, CABLE TRAY, OR

SUPPORTED BY CABLE HOOKS. PROVIDE BUSHINGS AT THE ENDS OF ALL

CONDUITS WHERE STUBBED ABOVE ACCESSIBLE CEILINGS OR WHERE DROPPED

INTO CABLE TRAYS. PROVIDE CABLE HOOKS ABOVE ACCESSIBLE CEILINGS FOR

CABLE INSTALLATION WHERE NOT INSTALLED IN A CONDUIT OR CABLE TRAY.

D BUILDINGS THAT HAVE CAMERAS THAT WORK OR WOULD WORK IF THE

SOFTWARE AND LICENSES WERE CURRENT SHOULD HAVE NEW NVRS INSTALLED

AND THE EXISTING CAMERAS CONNECTED TO THEM. AS NEW CAMERAS ARE

INSTALLED, REMOVE OLD CAMERAS FROM THE SYSTEM.

E ALL CABLES AND DEVICES TO BE LABELED. SEE SPECIFICATION AND DETAILS

FOR SPECIFIC REQUIREMENTS.

F THE EXISTING ACCESS CONTROL SYSTEM IS TO REMAIN IN USE UNTIL THE NEW

SYSTEM IS COMPLETE. DOORS SHOULD BE MIGRATED TO THE NEW SYSTEM ONE

AT A TIME UNTIL ALL ARE ON THE NEW SYSTEM. DURING THIS MIGRATION, NO

DOOR IS TO REMAIN UNSECURED OR INOPERABLE AT THE END OF A WORKDAY.

OFFICE

9'-0" ACT

OFFICE

9'-0" ACT

OFFICE

9'-0" ACT

OFFICE

9'-0" ACT

TELEDATA

9'-0" ACT

OFFICE

9'-0" ACT

OFFICE

9'-0" ACT

INTERVIEW

9'-0" ACT

INTERVIEW

9'-0" ACT

INTERVIEW

9'-0" ACT

OFFICE

9'-0" ACT

OFFICE

OFFICE

OFFICE

CSM

OFFICE

9'-0" ACT

INTERVIEW

9'-0" ACT

INTERVIEW

9'-0" ACT

INTERVIEW

9'-0" ACT

FILE

10'-0" ACT

WORK

STATIONS

10'-0"

OPEN OFFICE

WORKSTATIONS

10'-0" ACT

DHHR

LOBBY

10"-0" ACT

WORK

STATIONS

10'-0" ACT

CORRIDOR

10'-0" ACT

FAMILY

VISITATION

10'-0" ACT

MDT

CONFERENCE

ROOM

VIDEO

9'-0" ACT

UNISEX

TOILET

9'-0" ACT

RECEPTION

9'-0" ACT

OFFICE

9'-0" ACT

INTERVIEW

9'-0" ACT

INTERVIEW

9'-0" ACT

INTERVIEW

9'-0" ACT

OFFICE

9'-0" ACT

COPIER

9'-0" ACT

OFFICE

9'-0" ACT

BREAK

ROOM

10'-0" ACT

INTERVIEW

10'-0" ACT

MEN'S

9'-0" GYP

WOMEN'S

9'-0" GYP

OFFICE

9'-0" ACT

JAN

9'-0" GYP

ELEC

9'-0" ACT

CORRIDOR

9'-0" ACT

CORRIDOR

9'-0" ACT

CORRIDOR

9'-0" ACT

STAIR

S1

TOILET

9'-0" ACT

ELEV

E1

ELEV

E2

OFFICE

UNISEX

TOILET

9'-0" ACT

9'-0" ACT

OFFICE

9'-0" ACT

9'-0" ACT

OFFICE

9'-0" ACT

CORRIDOR

10'-0" ACT

CORRIDOR

9'-0" ACT

INTERVIEW

9'-0" ACT

OFFICE

9'-0" ACT

FREIGHT

E3

CORRIDOR

9'-0" ACT

WORK

STATIONS

9'-0"

9'-0" ACT

9'-0" ACT

WORK

STATIONS

10'-0"

WORK

STATIONS

9'-0"

DHHR

LOBBY

10"-0" ACT

DHS CASEWORK

AREA

CHILD

PROTECTIVE

SERVICES

UP

DN

UP

DN

DL

JB

WL

WL

PI

PI

PI

WL

WL

WL

WL

WL

WL

WL

WL

DL

JB

DL

DL

JB JB

JB JB

WL

PIPIPIPI

DL

DL

JBJB

JB JB

CRDC

WL

CR CR

DC

ACP ACP

CR

CR

DC

CR

CR

CRCR

DC

W L

PI

DC CR

DC

RECEPTION

NEW

NEW

(E)DL010

DC013

C018

TYPE A

C019

TYPE D

CR016

DC015

(E)DL012

C020

TYPE C

CR018

CR019

(E)DL013

DC017

CR020

C022

TYPE A (E)DL014

DC016

(E)WL032

C024

TYPE B

DC018

CR022

(E)DL015

CR021C021

TYPE A

(E)PI012

(E)PI011 (E)PI010

(E)PI009

CR013

(E)WL022

(E)WL023

ACP005ACP004SNR003

(E)WL024

DC014 (E)DL011

CR014CR015WL025

CR017

(E)WL033

(E)WL030

(E)WL031

(E)WL034(E)PI016

(E)PI015

(E)PI014

(E)WL028

(E)WL029

(E)WL027

(E)WL026

FILE:

DRAWN BY:

CHECKED BY:

PROJ. NO:

DRAWING NO:

DRAWING TITLE:

PROJECT NAME:

http://www.ZDSDesign.com

135 Corporate Center Drive Suite 532 Scott Depot, WV 25560

TEL 304/755-0075

FAX 304/755-0076

THIS SQUARE APPEARS 1/2"x1/2"

ON FULL SIZE SHEETS

CLIENT:

XXX

C :\U se rs

\e di so n.

ad ki ns \D oc um en ts

\G

SD

2C

_2

4-

-0 4_

BL

D

G

C

LA

R

KS

BU

R

G _e di so n.

ad ki ns

.rv t

8/

/2

:3 7:

P

M

53-TY-103

ELA

TZ3

GSD-252-C

SECOND FLOOR

SECURITY PLAN

BUILDING 53 SECURITY

SYSTEM UPGRADES

153 West Main Street Clarksburg, WV 26301

WEST VIRGINIA

GENERAL SERVICES

1/8" = 1'-0"53-TY-103

1 PROPOSED SECOND FLOOR SECURITY PLAN

KEYNOTES

1 EXISTING PANEL INTERFACE BOARDS (SCHLAGE PIM400-TD2) FOR EXISTING

SCHLAGE AD-400 WIRELESS NETWORK LOCKS TO REMAIN. INTEGRATE EXISTING

WIRELESS LOCKS INTO NEW SYSTEM.

2 NEW SECURITY NETWORK RACK. PROVIDE 12 STRAND MM OM4 ARMOURED FIBER

TO SNR002 AND SNR004. TERMINATE FIBER IN FIBER TERMINATION PANEL AT

BOTH ENDS. SEE SPECIFICATIONS AND DETAIL 1 ON SHEET 55-TY-501.

3 PROVIDE TWO 120V, 20A CIRCUITS FOR NEW SECURITY NETWORK RACK. CIRCUIT

TO NEAREST ELECTRICAL PANEL.

SECURITY SYSTEM SHEET NOTES

A SEE DETAIL SHEET FOR SECURITY CAMERA MOUNTING

B SEE SECURITY DEVICE SCHEDULE FOR ADDITIONAL INFORMATION

C ALL COMMUNICATION CABLES SHALL BE INSTALLED IN CONDUIT, CABLE TRAY, OR

SUPPORTED BY CABLE HOOKS. PROVIDE BUSHINGS AT THE ENDS OF ALL

CONDUITS WHERE STUBBED ABOVE ACCESSIBLE CEILINGS OR WHERE DROPPED

INTO CABLE TRAYS. PROVIDE CABLE HOOKS ABOVE ACCESSIBLE CEILINGS FOR

CABLE INSTALLATION WHERE NOT INSTALLED IN A CONDUIT OR CABLE TRAY.

D BUILDINGS THAT HAVE CAMERAS THAT WORK OR WOULD WORK IF THE

SOFTWARE AND LICENSES WERE CURRENT SHOULD HAVE NEW NVRS INSTALLED

AND THE EXISTING CAMERAS CONNECTED TO THEM. AS NEW CAMERAS ARE

INSTALLED, REMOVE OLD CAMERAS FROM THE SYSTEM.

E ALL CABLES AND DEVICES TO BE LABELED. SEE SPECIFICATION AND DETAILS

FOR SPECIFIC REQUIREMENTS.

F THE EXISTING ACCESS CONTROL SYSTEM IS TO REMAIN IN USE UNTIL THE NEW

SYSTEM IS COMPLETE. DOORS SHOULD BE MIGRATED TO THE NEW SYSTEM ONE

AT A TIME UNTIL ALL ARE ON THE NEW SYSTEM. DURING THIS MIGRATION, NO

DOOR IS TO REMAIN UNSECURED OR INOPERABLE AT THE END OF A WORKDAY.

TRAINING

ROOM

TRAINING

ROOM

CONFERENCE

ROOM

CLOSET

OFFICE

OFFICE

OFFICE

SMALL

COMPUTER

TRAINING

ROOM305

WOMEN'S

DHHR

TRAINING

LOBBY

OFFICE

9'-0" ACT

MEN'S

OFFICE

9'-0" ACT

TRAINING

ROOM

TRAINING

ROOM

TRAINING

ROOM

TELEDATA

JAN

CORRIDOR

WORK

STATIONS

OFFICE

CLOSET

316A

COPIER

318A

TRAINING

ROOM

BREAK

ROOM

10'-0" ACT

CORRIDOR

CORRIDOR

STAIR

S1

ELEV

E1

ELEV

E2

CORRIDOR

CONFERENCE

ROOM

OFFICE

CONFERENCE

FILE

OFFICE

OFFICE

BREAK

ROOM

OFFICE

OFFICE

FILE

9'-0" ACT

OFFICE

OFFICE

OFFICE

OFFICE

COPY

339A

RECEPTION

RECEPTION

CONFERENCE

10'-0" ACT

BREAK

ROOM

9'-0" ACT

CONFERENCE

AUDITOR

LOBBY

STATE

TAX

LOBBY

FREIGHT

E3

STORAGE

322A

ELEC

SECRETARY OF

STATE

WORK

STATIONS

CORRIDOR

3RD

FLOOR

LOBBY

CORRIDOR

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT 9'-0" ACT

10'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

10'-0" ACT

10'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" GYP

9'-0" GYP

9'-0" GYP

10'-0" ACT

10'-0" ACT

9'-0" ACT

9'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT 9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" ACT

9'-0" GYP

9'-0" GYP

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

9'-0" ACT

VETERANS

SERVICES

UP

DN

UP

DN

JB

DL

WL

WL

WL

WL

WL

WL

WL

WL

WL

WL

WL

DL

JB

PIPIPIPI

PI

PI

WL

CRDC

ACP

CRDC

C027

TYPE C

C028

TYPE D

(E)PI017

(E)PI018(E)PI019

(E)PI020

C053

TYPE C

C052

TYPE C

C051

TYPE A

CR023DC019

(E)DL016

(E)WL035

(E)WL036

(E)WL037

ACP006

SNR004

(E)WL042

(E)WL038

(E)WL040

(E)WL043

(E)WL044

(E)PI021

(E)PI022

(E)WL045

(E)WL046

CR024

(E)DL017

DC020

(E)WL039

(E)WL041

FILE:

DRAWN BY:

CHECKED BY:

PROJ. NO:

DRAWING NO:

DRAWING TITLE:

PROJECT NAME:

http://www.ZDSDesign.com

135 Corporate Center Drive Suite 532 Scott Depot, WV 25560

TEL 304/755-0075

FAX 304/755-0076

THIS SQUARE APPEARS 1/2"x1/2"

ON FULL SIZE SHEETS

CLIENT:

XXX

C :\U se rs

\e di so n.

ad ki ns \D oc um en ts

\G

SD

2C

_2

4-

-0 4_

BL

D

G

C

LA

R

KS

BU

R

G _e di so n.

ad ki ns

.rv t

8/

/2

:3 7:

P

M

53-TY-104

ELA

TZ3

GSD-252-C

THIRD FLOOR SECURITY

PLAN

BUILDING 53 SECURITY

SYSTEM UPGRADES

153 West Main Street Clarksburg, WV 26301

WEST VIRGINIA

GENERAL SERVICES

1/8" = 1'-0"53-TY-104

1 PROPOSED THIRD FLOOR SECURITY PLAN

KEYNOTES

1 EXISTING PANEL INTERFACE BOARDS (SCHLAGE PIM400-TD2) FOR EXISTING

SCHLAGE AD-400 WIRELESS NETWORK LOCKS TO REMAIN. INTEGRATE EXISTING

WIRELESS LOCKS INTO NEW SYSTEM.

2 NEW SECURITY NETWORK RACK. PROVIDE 12 STRAND MM OM4 ARMOURED FIBER

TO SNR003 AND SNR005. TERMINATE FIBER IN FIBER TERMINATION PANEL AT

BOTH ENDS. SEE SPECIFICATIONS AND DETAIL 1 ON SHEET 55-TY-501.

3 THIS DOOR LOCKS ON A SCHEDULE (UNLOCK DURING NORMAL BUSINESS HOURS).

CONFIRM REQUIRED SCHEDULE WITH AUDITOR ’S OFFICE.

4 PROVIDE TWO 120V, 20A CIRCUITS FOR NEW SECURITY NETWORK RACK. CIRCUIT

TO NEAREST ELECTRICAL PANEL.

5 THIS DOOR LOCKS ON A SCHEDULE (UNLOCK DURING NORMAL BUSINESS HOURS).

CONFIRM REQUIRED SCHEDULE WITH STATE TAX OFFICE.

SECURITY SYSTEM SHEET NOTES

A SEE DETAIL SHEET FOR SECURITY CAMERA MOUNTING

B SEE SECURITY DEVICE SCHEDULE FOR ADDITIONAL INFORMATION

C ALL COMMUNICATION CABLES SHALL BE INSTALLED IN CONDUIT, CABLE TRAY, OR

SUPPORTED BY CABLE HOOKS. PROVIDE BUSHINGS AT THE ENDS OF ALL

CONDUITS WHERE STUBBED ABOVE ACCESSIBLE CEILINGS OR WHERE DROPPED

INTO CABLE TRAYS. PROVIDE CABLE HOOKS ABOVE ACCESSIBLE CEILINGS FOR

CABLE INSTALLATION WHERE NOT INSTALLED IN A CONDUIT OR CABLE TRAY.

D BUILDINGS THAT HAVE CAMERAS THAT WORK OR WOULD WORK IF THE

SOFTWARE AND LICENSES WERE CURRENT SHOULD HAVE NEW NVRS INSTALLED

AND THE EXISTING CAMERAS CONNECTED TO THEM. AS NEW CAMERAS ARE

INSTALLED, REMOVE OLD CAMERAS FROM THE SYSTEM.

E ALL CABLES AND DEVICES TO BE LABELED. SEE SPECIFICATION AND DETAILS

FOR SPECIFIC REQUIREMENTS.

F THE EXISTING ACCESS CONTROL SYSTEM IS TO REMAIN IN USE UNTIL THE NEW

SYSTEM IS COMPLETE. DOORS SHOULD BE MIGRATED TO THE NEW SYSTEM ONE

AT A TIME UNTIL ALL ARE ON THE NEW SYSTEM. DURING THIS MIGRATION, NO

DOOR IS TO REMAIN UNSECURED OR INOPERABLE AT THE END OF A WORKDAY.

MEN'S

STAIR

S1

ELEV

E1

ELEV

E2

CORRIDOR

JANITOR

CONFERENCE/TRAINING

STORAGE

OFFICE

OFFICE

OFFICE

TOILET

OFFICE

TOILET

MAIL

406A

BREAK

ROOM

OFFICE

OFFICE

OFFICE

REHAB

LOBBY

OFFICE

TEL/DATA

OFFICE

OFFICE

FILE

RECEPTION

FREIGHT

E3

OFFICE

ELEC

CORRIDOR

CORRIDOR

STAIR

S2

RESERVE

CONFERENCE

ROOM

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

KITCHEN

OFFICE

OFFICE

OFFICE

OFFICE

UNASSIGNED

ROOM

CHILD SUPPORT

SERVICES

UNASSIGNED

ROOM

AUDITOR

OFFICE

UNASSIGNED

UNASSIGNED

UNASSIGNED

UNASSIGNED

OFFICE

OFFICE

425 OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

COPIER

421A

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT 10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

9'-0" ACT

9'-0" GYP

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

9'-0" ACT

9'-0" GYP 9'-0" GYP

9'-0" GYP

9'-0" GYP

9'-0" GYP

RESERVE

CONFERENCE

ROOM

10'-0" ACT

GYP BARREL CEILING

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT 10'-0" ACT

10'-0" ACT

10'-0" ACT

10'-0" ACT 10'-0" ACT

10'-0" ACT 10'-0" ACT

10'-0" ACT 10'-0" ACT

10'-0" ACT

DL

JB WL

WL

WL

PI PI

PI

PI

PI

WL WL

WL

PI

DL

JB WL

WL

W L

W L

CRDC

ACP

CRDC

C033

TYPE C

C032

TYPE D

DC022

ACP007

DC021

C058

TYPE N

C056

TYPE N

CR025

(E)DL018 (E)WL047

(E)WL048

(E)PI023

SNR005

(E)WL049

(E)WL050

(E)WL052

(E)WL053

(E)WL051

(E)WL054

(E)PI025

(E)PI026

(E)PI027

(E)PI028

(E)WL055

(E)WL056(E)DL019

CR026

FILE:

DRAWN BY:

CHECKED BY:

PROJ. NO:

DRAWING NO:

DRAWING TITLE:

PROJECT NAME:

http://www.ZDSDesign.com

135 Corporate Center Drive Suite 532 Scott Depot, WV 25560

TEL 304/755-0075

FAX 304/755-0076

THIS SQUARE APPEARS 1/2"x1/2"

ON FULL SIZE SHEETS

CLIENT:

XXX

C :\U se rs

\e di so n.

ad ki ns \D oc um en ts

\G

SD

2C

_2

4-

-0 4_

BL

D

G

C

LA

R

KS

BU

R

G _e di so n.

ad ki ns

.rv t

8/

/2

:3 7:

P

M

53-TY-105

ELA

TZ3

GSD-252-C

FOURTH FLOOR

SECURITY PLAN

BUILDING 53 SECURITY

SYSTEM UPGRADES

153 West Main Street Clarksburg, WV 26301

WEST VIRGINIA

GENERAL SERVICES

1/8" = 1'-0"53-TY-105

1 PROPOSED…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .