This is a special notice for an upcoming solicitation to provide initial outfitting services for a veterinary clinic at Naval Station Guantanamo Bay, Cuba. The U.S. Army Corps of Engineers Little Rock District intends to issue a request for quote set aside for small businesses only, with a NAICS code of 337127 and size standard of 500 employees. The estimated contract value is between $1 million and $3 million, with an estimated proposal due date of August 31, 2022. The simplified acquisition procedures of FAR Part 13 will be used in conjunction with commercial items procedures of FAR Part 12. No site visit is scheduled for the solicitation. ProjectNet will accept questions from August 3 to August 15, 2022 regarding draft documents attached to this notice, which are subject to change prior to issuance of the solicitation. The OFB goal date for this project is December 31, 2023.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Working Dog Treatment
Facility Replacement
100% Design Submittal Contract: N62450-14-D-0025 Task Order: N6945018F0872
Structural Interior Design (SID)
Volume I of II
US Naval Station Guantanamo Bay Guantanamo Bay, Cuba 7 March 2019
GeriGarami Text Box
FOR INFORMATION ONLY
WORKING DOG TREATMENT FACILITY REPLACEMENT MARCH 2019
TABLE OF CONTENTS
WORKING DOG TREATMENT FACILITY REPLACEMENT
US NAVAL STATION
GUANTANAMO BAY, CUBA
STRUCTURAL INTERIOR DESIGN (SID)
WORKING DOG TREATMENT FACILITY REPLACEMENT
US NAVAL STATION
GUANTANAMO BAY, CUBA
A/E Contract Number: N62450-14-D-0025 Delivery Order Number: P-89839 (FY19)
SS&A Project Number: 2018-013
TABLE OF CONTENTS
VOLUME I OF II
Narrative 1
Exterior Elevations, Exterior Finishes 2
Architectural Floor Plans 3
Finish Schedule 4
Color Design Legend 5
Interior Finish Plan 6
VOLUME II OF II
Interior Building Finishes 7
TAB 1.
Narrative
Section 2 – Interior Design Narrative
N62450-14-D-0025 | TASK ORDER: N6945018F0872 Working Dog Treatment Facility Replacement 2-1 NS Guantanamo Bay, Cuba
Section 2
Interior Design Narrative
2.1 Interior Partitions and Finishes
Typical interior partitions will be constructed of minimum 20-gauge, steel studs with 5/8” gypsum board on both sides at non-patient areas. All gypsum board will be mold resistant. At patient areas, interior partitions will be constructed of painted CMU or 20-gauge steel studs with clay tile over cement board on both sides. The large animal kennels will have 6” CMU or 4” CMU veneer walls for durability. All wall construction details will comply with applicable codes and standards. The partitions around the Imaging Room will be lined with
1/16” lead lining in accordance with the Physicist Report. See Appendix J for Physicist Report.
Interior doors will primarily be stained solid core wood doors with door armor where required.
Based on the Physicist Report, the Imaging Room will have a steel door. Lead lining at the door will not be required.
2.2 Materials Palette
All finishes are permanent in nature. Interior wall finishes include painted gypsum wallboard, gypsum wallboard with a latex epoxy coating, concrete block with a latex epoxy coating for kennel areas, and ceramic wall tile installed over cement backer board in wet areas. Washable, waterproof acoustical wall panels will be installed in the animal holding areas at six feet above the finished floor. Ceilings will be a combination of suspended acoustical panels, exposed structure, and painted gypsum wallboard. Flooring materials will be a combination of rubber tile, epoxy flooring, sealed concrete, and through color porcelain tile in wet areas. Rubber base will be used in conjunction with rubber tile and sealed concrete floors. Epoxy floors will have an integral base. Through color porcelain tile cove base will be used in conjunction with through color porcelain tile floors. Rubber tile with rubber base is proposed for the lobby area and administrative spaces. Epoxy flooring is proposed for the treatment areas and animal holding areas.
GeriGarami F I O
TAB 2.
Exterior Elevations & Exterior Finishes
A B B.7 B.9 C
'-0
SPLIT FACE CMU (CMU1)
STANDING SEAM ALUMINUM ROOF
PRE-FINISHED
ALUMINUM FASCIA
TOP OF MASONRY
12'-0"
0'-0"
FINISHED FLOOR
PRE-FINISHED ALUMINUM
DOWNSPOUT - TYPICAL
PRE-FINISHED
ALUMINUM GUTTER
ALUMINUM STOREFRONT
FRAMING SYSTEM
SPLIT FACE CMU (CMU1)
SPANDREL GLASS PANEL IN
STOREFRONT
ALUMINUM STOREFRONT
FRAMING SYSTEM
PAINTED 5"X5" TUBE STEEL COLUMN
PAINTED 8"X6" STRUCTURAL TUBE STEEL BEAM
ALUM. STOREFRONT
FRAMING SYSTEM
PAINTED STEEL
ORNAMENTAL
BRACKET
CONCRETE
SPLASH BLOCK
- TYPICAL
BREAK METAL
TRIM
CJCJ
REEL MACHINE (SEE PLUMBING)
REEL MACHINE
(SEE
PLUMBING)
K3420 K3420
BUILDING NUMBER SIGN
SMOOTH FACE CMU
(CMU2) AT TOP OF COURSE
SEE ELECTRICAL
(TYP.)
B AB.7B.9C
'-0
SPLIT FACE CMU (CMU1)
STANDING SEAM ALUMINUM ROOF
PRE-FINISHED ALUMINUM
DOWNSPOUT - TYPICAL
PRE-FINISHED
ALUMINUM FASCIA
PRE-FINSIHED ALUMINUM GUTTER
TOP OF MASONRY
12'-0"
0'-0"
FINISHED FLOOR
ALUMINUM STOREFRONT
SYSTEM
CONCRETE SPLASH
BLOCK -TYPICAL PRE-FABRICATED ALUM. CANOPY
AT EXTERIOR CAGE WASH AREA
WALL MOUNTED LIGHT FIXTURE
(SEE LIGHTING PLAN)
BREAK METAL TRIIM
CJ CJ CJCJ
REEL MACHINE (SEE PLUMBING)SLEEVE THROUGH CMU MASONRY GRIND CMU SMOOTH
AND SEAL AND PRE-FINISHED ALUM. ESCUTCHEON FOR
ANESTHESIA GAS DISPOSAL VENT (SEE PLUMBING)
REEL MACHINE
(SEE PLUMBING)
K3420
K3420
SMOOTH FACE CMU
(CMU2) AT TOP OF
COURSE
POWER EXHAUST FAN
POWER EXHAUST FAN
SEE ELECTRICAL
(TYP.)
LEGEND
CONTROL JOINT, SEE DET. A4/A-301CJ
A
B
C
D
1 2 3 4
1 2 3 4
A
B
C
D
IP
T
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
SCALE:
PROJECT NO:
CONSTR CONTR NO:
NAVFAC DRAWING NO:
SHEET: OF
DRAWFORM REVISION: 10 MAY 2014
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
UNCLASSIFIED//FOR OFFICIAL USE ONLY
FIRE PROTECTION
CHIEF ENG/ARCH
BRANCH MGR
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
03/07/19
0%
S
UBM
IT
TAL
N O
T F O
R C
O
NSTRU
CTIO
N
3' 6' 12'
SCALE: 3/16"=1'-0"
NAVFAC SE
NAS JACKSONVILLE, FL
VETERINARY CLINIC
NS GUANTANAMO BAY, CUBA
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C L A
S S
IF
IE
D
F O
R O
F F
IC
IA
L U
S E
O N
L Y
U N
C L A
S S
IF
IE
D
F O
R O
F F
IC
IA
L U
S E
O N
L Y Stanley
Consultants INC.
/6
/2
:3
:5
P M
C
U s e rs \h a ll_ c \ D o c u m e n ts \B
L D
G -0
-1
-A h a ll_ c .r v t
As indicated
A-201
15930331
W O
R K
IN
G
D O
G T
R E
A T
M E
N T
F A
C
IL
IT
Y
R E
P L
A C
E M
E N
T
E X
T E
R
IO
R E
L E
V A
T
IO
N S
G U
A N
T A
N A
M O
B A
Y , C
U B
A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
15125996
PLZ VDS PLZ
U .S
N
A V
A L
S T
A T
IO
N
SCALE: 3/16" = 1'-0"
SOUTH ELEVATION
C1 REF: A-111
SCALE: 3/16" = 1'-0"
NORTH ELEVATION
A1 REF: A-111
1. SEE SIGN TYPE XBA FOR BUILDING NUMBER
SIGN ON SHEET AF112. COORDINATE LOCATION
OF BUILDING NUMBER SIGN WITH GOVERMENT'S
REPRESENTATIVE BEFORE INSTALLING BUILDING
NUMBER SIGNS.
2. SEE MISCELLANEOUS EXTERIOR FINISHES ON
SHEET A-661 FOR LISTING OF EXTERIOR FINISH
MATERIALS AND COLORS.
GENERAL NOTES
3/16" = 1'-0"
2 3 41
'-0
SPLIT FACE CMU (CMU1)
STANDING SEAM ALUMINUM ROOF
PRE-FINISHED
ALUMINUM FASCIA
TOP OF MASONRY
12'-0"
0'-0"
FINISHED FLOOR
ALUMINUM STOREFRONT
FRAMING SYSTEM
PRE-FINISHED ALUMINUM
GUTTER
PAINTED STEEL ORNAMENTAL BRACKET
PRE-FINISHED ALUMINUM GUTTER
SPANDREL GLASS IN STOREFRONT
SYSTEM
PAINTED 5"X5" TUBE STEEL COLUMN
ALUMINUM STOREFRONT
FRAMING SYSTEM
PAINTED 8"X6" TUBE STEEL BEAM
PRE-FINISHED ALUMINUM
DOWNSPOUT - TYPICAL
CONCRETE SPLASH
BLOCK - TYPICAL
PRE-FABRICATED ALUM. CANOPY
AT EXTERIOR CAGE WASH AREA
WALL MOUNTED
LIGHT FIXTURE
(SEE LIGHTING PLAN)
CJCJCJ
REEL MACHINE
& HOSE BIBB
(SEE
PLUMBING)
REEL MACHINE & HOSE BIB (SEE
PLUMBING)
K3420
K3420
SMOOTH FACE CMU
(CMU2) AT TOP OF COURSE
POWER EXHAUST FAN
POWER EXHAUST FAN
SEE ELECTRICAL
(TYP.)
4 3 2 1
'-0
3' -4
6'
-8
6' -0
4'
-0
STANDING SEAM ALUMINUM ROOF
PRE-FINISHED
ALUMINUM
DOWNSPOUT
PRE-FINISHED ALUMINUM GUTTER
TOP OF MASONRY
12'-0"
0'-0"
FINISHED FLOOR
PRE-FINISHED
ALUMINUM FASCIA
PRE-FINISHED ALUMINUM
GUTTER
PAINTED STEEL ORNAMENTAL BRACKET
SPANDREL GLASS PANEL IN
STOREFRONT SYSTEM
PAINTED 5"x5" TUBE STEEL COLUMN
ALUMINUM STOREFRONT
FRAMING SYSTEM
OPENING IN
CMU END
WALL - CMU
BEYOND
WALL MOUNTED LIGHT FIXTURE
(SEE LIGHTING PLAN)
PAINTED 8"x6" TUBE STEEL BEAM
CONCRETE SPLASH BLOCK
-TYPICAL
ALUMINUM
STOREFRONT
FRAMING SYSTEM
CJ CJ
REEL MACHINE
& HOSE BIBB
(SEE
PLUMBING)
BUILDING NUMBER SIGN
K3420
SPLIT FACE CMU (CMU1)
SMOOTH FACE CMU (CMU2)
AT TOP OF COURSE
4" CONCRETE
CAP
SEE FP
SEE ELECTRICAL
(TYP.)
C5
A-610
LEGEND
CONTROL JOINT, SEE DET. A4/A-301CJ
A
B
C
D
1 2 3 4
1 2 3 4
A
B
C
D
IP
T
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
SCALE:
PROJECT NO:
CONSTR CONTR NO:
NAVFAC DRAWING NO:
SHEET: OF
DRAWFORM REVISION: 10 MAY 2014
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
UNCLASSIFIED//FOR OFFICIAL USE ONLY
FIRE PROTECTION
CHIEF ENG/ARCH
BRANCH MGR
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
03/07/19
0%
S
UBM
IT
TAL
N O
T F O
R C
O
NSTRU
CTIO
N
3' 6' 12'
SCALE: 3/16"=1'-0"
NAVFAC SE
NAS JACKSONVILLE, FL
VETERINARY CLINIC
NS GUANTANAMO BAY, CUBA
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C L A
S S
IF
IE
D
F O
R O
F F
IC
IA
L U
S E
O N
L Y
U N
C L A
S S
IF
IE
D
F O
R O
F F
IC
IA
L U
S E
O N
L Y Stanley
Consultants INC.
/6
/2
:3
:5
P M
C
U s e rs \h a ll_ c \ D o c u m e n ts \B
L D
G -0
-1
-A h a ll_ c .r v t
As indicated
A-202
15930331
W O
R K
IN
G
D O
G T
R E
A T
M E
N T
F A
C
IL
IT
Y
R E
P L
A C
E M
E N
T
E X
T E
R
IO
R E
L E
V A
T
IO
N S
G U
A N
T A
N A
M O
B A
Y , C
U B
A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
15125997
PLZ VDS PLZ
U .S
N
A V
A L
S T
A T
IO
N
SCALE: 3/16" = 1'-0"
EAST ELEVATION
C1 REF: A-111
SCALE: 3/16" = 1'-0"
WEST ELEVATION
A1 REF: A-111
1. SEE SIGN TYPE XBA FOR BUILDING NUMBER
SIGN ON SHEET AF112. COORDINATE LOCATION
OF BUILDING NUMBER SIGN WITH GOVERMENT'S
REPRESENTATIVE BEFORE INSTALLING BUILDING
NUMBER SIGNS.
2. SEE MISCELLANEOUS EXTERIOR FINISHES ON
SHEET A-661 FOR LISTING OF EXTERIOR FINISH
MATERIALS AND COLORS.
GENERAL NOTES
3/16" = 1'-0"
WORKING DOG TREATMENT FACILITY REPLACEMENT MARCH 2019
EXTERIOR BUILDING FINISHES
WORKING DOG TREATMENT FACILITY REPLACEMENT
US NAVAL STATION
GUANTANAMO BAY, CUBA
EXPOSED STEEL BEAMS AND COLUMNS
PRODUCT: SHERWIN WILLIAMS
COLOR: MATCH KAWNEER BONE WHITE
GLOSS LEVEL: G5 (SEMI GLOSS)
STOREFRONT DOORS
MANUFACTURERE: KAWNEER
MATERIAL: ALUMINUM
COLOR: TERRA COTTA METALLIC
STEEL DOORS
PRODUCT: SHERWIN WILLIAMS
COLOR: 6342 SPICY HUE
DOOR FRAMES
PRODUCT: SHERWIN WILLIAMS
COLOR: MATCH KAWNEER BONE WHITE
TAB 3.
Architectural Floor Plans
DIMENSION TO FACE OF STEEL
STUD OR MASONRY WALLS. REFER
TO WALL TYPES FOR STUD WALL
THICKNESS UNLESS SPECIFICALLY
NOTED OTHERWISE
PLAN LEGEND
ROOMNAME
3' - 0"
EXTERIOR WALL
INTERIOR WALL CONSTRUCTION
ONE HOUR FIRE BARRIER
SMOKE PARTITION
(NON-FIRE RATED)
ROOM NAME AND NUMBER
SMOKE BARRIER
(NON-FIRE RATED)
ONE HOUR FIRE AND SMOKE BARRIER
A B C
B.7 B.9
CAGE WASH
PAD
25' - 8" 8' - 0" 52' - 0"
2'
3'
25' - 8" 8' - 0" 52' - 0"
85' - 8"
2'
6' - 4"
MWD EXAM /
ISO HOLD
A30
LAUNDRY
ROOM
A27
LINEN, CLEAN
A27A
UTILITY, SOILED
A29
OFFICE, OIC
A05
OFFICE, NCOIC
A03
VET TECH
VET TECH
A07 STORAGE,
FILES COPY / OFFICE
SUPPLY
STORAGE,
CONSUMABLES
RECEPTION
A09
LOBBY /
WAITING
A13
EXAM /
TREATMENT,
POA
A14
EXAM /
TREATMENT
ROOM
A12
TOILET, PUBLIC
A10
IMAGING
A22
LOCKER/CHANGING
ROOM, STAFF
A06
STORAGE,
EQUIPMENT
A28
OFFICE, FOOD
INSPECTORS
A01
CONFERENCE
ROOM /
BREAKROOM
A02
VESTIBULE
A13A
KITCHENETTE
A04
PHARMACY
A17
CENTRAL
MEDICAL
SUPPLY
LABORATORY
A19
STORAGE,
FREEZER
SCRUB / GOWN
AREA
INSTRUMENT
PREP
A20
OPERATING
ROOM
A21
TOILET, STAFF
A24
KENNELS LG
ANIMALS
A25
JANITOR
CLOSET
A26
HOLDING, SM
ANIMALS
A33 RECEIVING /
STAGING AREA
AC6
COMM
A31
CAGE WASH
MECHANICAL
B01
FOOD PREP
AC6A
ELECTRICAL
B02
CORRIDOR
AC1
CORRIDOR
AC4
CORRIDOR
AC8
CORRIDOR
AC5
CORRIDOR
AC3
CORRIDOR
AC2
ANTE-ROOM
AC7
0"
6'
A-201
A1
A-202C1
A-201
C1
A-202 A1
DETACHED
CANOPY
ABOVE
A4
A-310
A3
A-313
A1
A-311
Sim
A3
A-312 A2
A-310
A2
A-310
A4
A-310
LEADING EDGE OF LANDING
A1
A-301
A1
A-301
C1
A-301
C1
A-301
8' - 0" 6' - 0"
A-160
A1
A-543
A2
A-543
A1
KEY PLAN
PLAN
NORTH
1A
1B
A
B
C
D
1 2 3 4
1 2 3 4
A
B
C
D
IP
T
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
SCALE:
PROJECT NO:
CONSTR CONTR NO:
NAVFAC DRAWING NO:
SHEET: OF
DRAWFORM REVISION: 10 MAY 2014
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
UNCLASSIFIED//FOR OFFICIAL USE ONLY
FIRE PROTECTION
CHIEF ENG/ARCH
BRANCH MGR
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
03/07/19
0%
S
UBM
IT
TAL
N O
T F O
R C
O
NSTRU
CTIO
N
3' 6' 12'
SCALE: 3/16"=1'-0"
A1
NAVFAC SE
NAS JACKSONVILLE, FL
VETERINARY CLINIC
NS GUANTANAMO BAY, CUBA
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C L A
S S
IF
IE
D
F O
R O
F F
IC
IA
L U
S E
O N
L Y
U N
C L A
S S
IF
IE
D
F O
R O
F F
IC
IA
L U
S E
O N
L Y Stanley
Consultants INC.
/6
/2
:3
:4
P M
C
U s e rs \h a ll_ c \ D o c u m e n ts \B
L D
G -0
-1
-A h a ll_ c .r v t
3/16" = 1'-0"
SCALE: 3/16" = 1'-0"
A-111
15930331
W O
R K
IN
G
D O
G T
R E
A T
M E
N T
F A
C
IL
IT
Y
R E
P L
A C
E M
E N
T
F L O
O R
P L A
N
C O
M P
O S
IT
E
G U
A N
T A
N A
M O
B A
Y , C
U B
A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
15125990
PLZ PLZ PLZ
FLOOR PLAN - COMPOSITE
U .S
N
A V
A L
S T
A T
IO
N
36 171
A
MWD EXAM /
ISO HOLD
A30
LAUNDRY
ROOM
A27
UTILITY, SOILED
A29
OFFICE, OIC
A05
OFFICE, NCOIC
A03
VET TECH
A07
RECEPTION
A09
LOBBY /
WAITING
A13
EXAM /
TREATMENT,
POA
A14
EXAM /
TREATMENT
ROOM
A12
TOILET, PUBLIC
A10
IMAGING
A22
LOCKER/CHANGING
ROOM, STAFF
A06
STORAGE,
EQUIPMENT
A28
OFFICE, FOOD
INSPECTORS
A01
CONFERENCE
ROOM /
BREAKROOM
A02
VESTIBULE
A13A
KITCHENETTE
A04
PHARMACY
A17
LABORATORY
A19
INSTRUMENT
PREP
A20
OPERATING
ROOM
A21
TOILET, STAFF
A24
KENNELS LG
ANIMALS
A25
JANITOR
CLOSET
A26
HOLDING, SM
ANIMALS
A33
RECEIVING /
STAGING AREA
AC6
COMM
A31
FOOD PREP
AC6A
CORRIDOR
AC1
CORRIDOR
AC4
CORRIDOR
AC8
CORRIDOR
AC5
CORRIDOR
AC3
CORRIDOR
AC2
ANTE-ROOM
AC7
A-430D1
B C
B.7 B.9
A-410
A1
A-430 D2
A-430
A-430
B1
A-430
A-430 B2
A-430 A1
A-430A2
A-410
C1
A17A21A27
A24A26
A25 A33
A29
AC6
A31
AC7A
AC7
AC5
A14A
A14A12
A12A
A10
AC4
A22 A28
AC2
A30
A02
A01 A03 A05 A07
A06
A09
AC1
A13B
A13A
A-430 A3
85' - 8"
8' - 8"
M.O.
5' - 4" 3' - 4"
M.O.
5' - 4" 6' - 8"
M.O.
5' - 4" 3' - 4"
M.O.
5' - 4" 6' - 8"
M.O.
5' - 4" 3' - 4"
M.O.
5' - 4" 7' - 8" 8' - 0" 6' - 0"
2'
M .O
2'
2'
M .O
5'
2'
M .O
2'
2'
M .O
2'
M .O
4'
4" 4' - 4" 3' - 4" 2' - 8"
M.O.
2' - 8"
3'
8" M
.O
2'
5'
M .O
3'
9'
6'
5'
4'
M .O
5'
6'
M .O
5'
4'
9'
6' - 4"
2'
11' - 5 3/4" 4' - 5" 10' - 6 5/8" 10' - 6 5/8" 11' - 5" 10' - 7 1/4" 8' - 9 1/8" 4' - 0" 13' - 10 5/8"
17' - 7 5/8" 12' - 8 3/4" 13' - 11 5/8" 11' - 4"11' - 5 3/4" 6' - 9 3/8" 11' - 8 7/8"
5' - 1 1/4" 7' - 1" 6' - 11" 1' - 0" 7' - 8 5/8" 10' - 5 3/4" 5' - 1 1/4" 10' - 11 3/8" 9' - 5" 10' - 5"
3' - 0"
3'
/8
5'
/4
5'
/4
8'
/2
5'
/4
6'
/8
9'
/4
7'
/8
7'
/8
3'
/4
4'
/4
8'
1/ 8"
8'
/8
4'
/8
5'
5/ 8"
6'
/8
5'
/4
6'
/8
ALIGN
A
LI
G N
W4 W4 W4 W4 W4 W4
W4
W3
W3
W3
W3
W3
W6
W5
W6
W4
W4
W8
W7 10A
8B
8B
8C
8C
8B
8A
888B
8B
7 8
2B
8A
8C
2C
2A
2A 2C
2D
10B
10A
10B
4A
3A
2A
2A
8B
8B
5'
5"
M .O
3'
A5075
A5090
A5145
M7490
X4600
A5145
A5145A5145
A5145 A5145
A5145 A5145
A
A
UR221
A5145A5220 A5145
A5075
A5082 P3000
UA511
UA510
A5080
U A
A5075
CS150
P1965
CD040
CD040
CD040
A1080
K
K3420
A
UA510 UA511
A
A5077
K3420
P9050 A1067
A5075
A5082
P3000
A5145
A5116 A1067 P3000
A5082
A5075
CT020
A5210P
CB020
CD040
CD040
U A
U A
1 A
A
C S
A5077
P5040 A5075
A5030 A5110
A5170 A5205 P9050
A5075
A1067
P3000
A5082
A5090
A5116
A5017
F
A5145 A5145 A5145
A5145
C D
A5145
CD040
M7405
M7405
K3420
A5077
UA510
UA511
A5145
M7405
A5080
CD040
C03P0
CS150
M1803
P2000
A5116
A5119
A5080UA511
P2000
P4700 A5075 A5135
CT050
CS230
A5075
A5080
CD040
A
A
P8710
C D
0P
C D
CD040
CQ030M
F3050
A5075
A5077
UA510
UA511
A5145
M7405
A5080
CD040
C03P0
CS150
M1803
M1803
A5080
A5080
A5075
UV003
UV003
UV003
UV003
UV003
UV003
UV003
A5080
4' - 10"
4' - 0"
C T
C
P
CT050
A5150
A5150
C T
P2451
CT020
C04F0
CT050
C04F0
CT020CT020
P9050
A5200
A5119
CT020
X2125
X3150
A5119
A5200
P2451
CS150
CT020
C04F0B
A5090 A5200
A-411
C1
A6309 A6309 A6309 A6309 A6309A6309
A6309
A6309
A6309
A6309
A6309
A6309
CG2
CG1 CG1
CG1
CG1
CG1
CG1
CG1
CG1
BR1
BR1 BR1BR1 BR1BR1
BR1
BR1
BR1
BR1
BR1
BR1BR1
BR1
BR1
ALIGN
FEC
A-630
D2
A-630
D2
B R
BR1
W9
D3
D4
FEC
A-430B3
P6500
A-430
A4
A-430D2
MIR.
A-430 B5
SIM.
C5
A-610
A5145
F
A5075
CG1
C03P0
C03P0B
A5080 A5075
CG1
F3050
F3025
C
G
C
G
U V
U V
P2451
UA003
UT030
F3025 F3050 F3050
A
FE
2'
.0
0°
DIMENSION TO FACE OF STEEL
STUD OR MASONRY WALLS. REFER
TO WALL TYPES FOR STUD WALL
THICKNESS UNLESS SPECIFICALLY
NOTED OTHERWISE
PLAN LEGEND
ROOMNAME
3' - 0"
EXTERIOR WALL
INTERIOR WALL CONSTRUCTION
ONE HOUR FIRE BARRIER
SMOKE PARTITION
(NON-FIRE RATED)
ROOM NAME AND NUMBER
GENERAL NOTES:
1. SEE A-680 SERIES SHEETS FOR
EQUIPMENT IDENTIFICATION AND
EQUIPMENT SCHEDULE.
2. ALL DIMENSIONS ARE FROM FACE OF
STUD TO FACE OF STUD OR FACE OF CMU
BLOCK TYPICALLY. DIMENSIONS NOTED
AS "CLEAR" ARE FACE TO FINISHED WALL
TO FACE OF FINISHED WALL.
SMOKE BARRIER
(NON-FIRE RATED)
A1066
FEC
JSN NUMBER, SEE EQUIPMENT
SHEETS FOR IDENTIFICATION
FIRE EXTINGUISHER IN CABINET,
SEMI RECESSED
(SEE DETAIL B1/A-543)
DOOR NUMBER SYMBOL
SEE DOOR SCHEDULE ON SHEETS
A-610 THROUGH A-616
FE FIRE EXTINGUISHER, WALL HUNG
1A
CG1, CG2
CORNER GUARD TYPE
(SEE DETAIL C5/A-510 & 4 /A-542)
WALL TYPE SYMBOL,
SEE A-550 SERIES SHEETS FOR
WALL TYPES
W1
WINDOW TYPE SYMBOL,
SEE SHEET A-620
BR1 BUMPER RAIL (SEE DETAIL
B5/A-542)
CJ-1 CONTROL JOINT,
SEE DETAIL A-542
LOUVER TYPE SYMBOL,
SEE SHEET A-620
L1
KEY PLAN
PLAN
NORTH
1A
1B
A
B
C
D
1 2 3 4
1 2 3 4
A
B
C
D
IP
T
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
SCALE:
PROJECT NO:
CONSTR CONTR NO:
NAVFAC DRAWING NO:
SHEET: OF
DRAWFORM REVISION: 10 MAY 2014
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
UNCLASSIFIED//FOR OFFICIAL USE ONLY
FIRE PROTECTION
CHIEF ENG/ARCH
BRANCH MGR
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
03/07/19
0%
S
UBM
IT
TAL
N O
T F O
R C
O
NSTRU
CTIO
N
2' 4' 8'
SCALE: 1/4"=1'-0"
A1
NAVFAC SE
NAS JACKSONVILLE, FL
VETERINARY CLINIC
NS GUANTANAMO BAY, CUBA
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C L A
S S
IF
IE
D
F O
R O
F F
IC
IA
L U
S E
O N
L Y
U N
C L A
S S
IF
IE
D
F O
R O
F F
IC
IA
L U
S E
O N
L Y Stanley
Consultants INC.
/6
/2
:3
:4
P M
C
U s e rs \h a ll_ c \ D o c u m e n ts \B
L D
G -0
-1
-A h a ll_ c .r v t
1/4" = 1'-0"
SCALE: 1/4" = 1'-0"
A-112
15930331
W O
R K
IN
G
D O
G T
R E
A T
M E
N T
F A
C
IL
IT
Y
R E
P L
A C
E M
E N
T
F L O
O R
P L A
N
B L O
C K
A
G U
A N
T A
N A
M O
B A
Y , C
U B
A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
15125991
PLZ PLZ PLZ
FLOOR PLAN - BLOCK A
U .S
N
A V
A L
S T
A T
IO
N
17137
A
CAGE WASH
MECHANICAL
B01
ELECTRICAL
B02
B C
CAGE WASH
PAD
DETACHED PRE-
FABRICATED CANOPY
ABOVE
B02
B01
2'
M .O
4'
M .O
6'
4" 4' - 4" 3' - 4" 2' - 8"
M.O.
2' - 8"
3'
8" M
.O
2'
5'
9' - 6"
7'
/2
3'
/4
W3
W3
K3420
L1
2'
M .O
4'
FE
2'
.0
0°
DIMENSION TO FACE OF STEEL
STUD OR MASONRY WALLS. REFER
TO WALL TYPES FOR STUD WALL
THICKNESS UNLESS SPECIFICALLY
NOTED OTHERWISE
PLAN LEGEND
ROOMNAME
3' - 0"
EXTERIOR WALL
INTERIOR WALL CONSTRUCTION
ONE HOUR FIRE BARRIER
SMOKE PARTITION
(NON-FIRE RATED)
ROOM NAME AND NUMBER
GENERAL NOTES:
1. SEE A-680 SERIES SHEETS FOR
EQUIPMENT IDENTIFICATION AND
EQUIPMENT SCHEDULE.
2. ALL DIMENSIONS ARE FROM FACE OF
STUD TO FACE OF STUD OR FACE OF CMU
BLOCK TYPICALLY. DIMENSIONS NOTED
AS "CLEAR" ARE FACE TO FINISHED WALL
TO FACE OF FINISHED WALL.
SMOKE BARRIER
(NON-FIRE RATED)
A1066
FEC
JSN NUMBER, SEE EQUIPMENT
SHEETS FOR IDENTIFICATION
FIRE EXTINGUISHER IN CABINET,
SEMI RECESSED
(SEE DETAIL B1/A-543)
DOOR NUMBER SYMBOL
SEE DOOR SCHEDULE ON SHEETS
A-610 THROUGH A-616
FE FIRE EXTINGUISHER, WALL HUNG
1A
CG1, CG2
CORNER GUARD TYPE
(SEE DETAIL C5/A-510 & 4 /A-542)
WALL TYPE SYMBOL,
SEE A-550 SERIES SHEETS FOR
WALL TYPES
W1
WINDOW TYPE SYMBOL,
SEE SHEET A-620
BR1 BUMPER RAIL (SEE DETAIL
B5/A-542)
CJ-1 CONTROL JOINT,
SEE DETAIL A-542
LOUVER TYPE SYMBOL,
SEE SHEET A-620
L1
KEY PLAN
PLAN
NORTH
1A
1B
A
B
C
D
1 2 3 4
1 2 3 4
A
B
C
D
IP
T
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
SCALE:
PROJECT NO:
CONSTR CONTR NO:
NAVFAC DRAWING NO:
SHEET: OF
DRAWFORM REVISION: 10 MAY 2014
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
UNCLASSIFIED//FOR OFFICIAL USE ONLY
FIRE PROTECTION
CHIEF ENG/ARCH
BRANCH MGR
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
03/07/19
0%
S
UBM
IT
TAL
N O
T F O
R C
O
NSTRU
CTIO
N
2' 4' 8'
SCALE: 1/4"=1'-0"
A1
NAVFAC SE
NAS JACKSONVILLE, FL
VETERINARY CLINIC
NS GUANTANAMO BAY, CUBA
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C L A
S S
IF
IE
D
F O
R O
F F
IC
IA
L U
S E
O N
L Y
U N
C L A
S S
IF
IE
D
F O
R O
F F
IC
IA
L U
S E
O N
L Y Stanley
Consultants INC.
/6
/2
:3
:4
P M
C
U s e rs \h a ll_ c \ D o c u m e n ts \B
L D
G -0
-1
-A h a ll_ c .r v t
1/4" = 1'-0"
SCALE: 1/4" = 1'-0"
A-113
15930331
W O
R K
IN
G
D O
G T
R E
A T
M E
N T
F A
C
IL
IT
Y
R E
P L
A C
E M
E N
T
F L O
O R
P L A
N
B L O
C K
B
G U
A N
T A
N A
M O
B A
Y , C
U B
A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
15125992
PLZ PLZ PLZ
FLOOR PLAN - BLOCK B
U .S
N
A V
A L
S T
A T
IO
N
17138
TAB 4.
Finish Schedule
1. MANUFACTURER REFERENCES NOTED PROVIDE BASIS OF DESIGN FOR MATERIALS,
COLORS, AND PATTERN ONLY. PRODUCTS BY OTHER MANUFACTURERS MAY BE
ACCEPTABLE SUBJECT TO PROVIDING AN ACCEPTABLE MATCH AND EQUAL
COMPLYING REQUIREMENTS OF THE SPECIFICATIONS.
2. THE FINISH SCHEDULE LISTS THE ROOMS IN THE PROJECT. IT LISTS ROOM
NUMBERS WHICH ARE SHOWN ON THE ARCHITECTURAL FLOOR PLANS CONTAINED
IN THE A-100 SHEET SERIES.
3. SEE REFLECTED CEILING PLANS ON A-800 SERIES SHEETS FOR ALL CEILING
HEIGHTS AND CONFIGURATIONS.
4. SEE DETAIL A2/A-542 FOR INTREGAL BASE.
ABBREVIATIONS LEGEND
AP ACOUSTICAL WALL PANEL
AT ACOUSTICAL CEILING TILE
BEP CONCRETE BLOCK, EPOXY COATING
BPT CONCRETE BLOCK, PAINTED
CS SEALED CONCRETE
CT CERAMIC TILE
CTB CERAMIC TILE BASE
ER EPOXY RESIN
EXP EXPOSED
GEL GYPSUM WALLBOARD - EPOXY COATING,LEAD LINED
GEP GYPSUM WALLBOARD - EPOXY COATING
GPT GYPSUM WALLBOARD - PAINTED
GCT GYPSUM WALLBOARD - TILE
IR INTEGRAL EPOXY RESIN BASE
PL PLASTIC LAMINATE
PT PAINT
RB RESILIENT BASE
RT RUBBER TILE FLOORING
SCCS STATIC CONTROL CONCRETE SEALER
SCONC HARDENED AND SEALED CONCRETE
SS SOLID SURFACE
WP WALL PROTECTION
* SEE REMARKS COLUMN
FINISH SCHEDULE REMARKS
NOTE 1 PROVIDE CT2 WITHIN SHOWER FLOOR AREA.
NOTE 2 APPLY WALL PROTECTION (WP1) TO WALLS AT SCALE AND WATER COOLER.
SEE FINISH PLAN AF-111.
NOTE 4 PROVIDE SOLID SURFACE (SS1) TRANSACTION COUNTER, ADA HEIGHT AT
LOBBY RECEPTION. PROVIDE 1/2" THICK SOLID SURFACE PANEL AT START
OF WALL LEFT OF TRANSACTION COUNTER, UNDERNEATH AND TO END OF
WALL ON RIGHT. SEE FINISH PLAN AF-111 AND ELEVATION, SHEET A-250 FOR
LOCATION AND FINISH HEIGHT.
NOTE 5 CASEWORK TO BE PL1 AND SS1 FOR KITCHENETTE AND EXAM / TREATMENT
ROOMS.
NOTE 6 PROVIDE ACOUSTICAL WALL PANELS (AP) FOR LARGE ANIMAL KENNEL AND
SMALL ANIMAL HOLDING. SEE FINISH PLAN AF-111.
NOTE 7 PROVIDE COLD WELD INSTALLTION BETWEEN EACH TILE AND AT SANITARY
COVE BASE, BY MANUFACTURERS SPECIFICATION, FOR RUBBER TILES IN
VESTIBULE, WAITING AND CORRIODR.
NOTE 8 PROVIDE RUNNING BOND INSTALLATION WITH COLD WELD ONLY AT
SANITARY COVE BASE SEAM.
ROOM FINISH SCHEDULE GENERAL NOTES
A
B
C
D
1 2 3 4
1 2 3 4
A
B
C
D
IP
T
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
SCALE:
PROJECT NO:
CONSTR CONTR NO:
NAVFAC DRAWING NO:
SHEET: OF
DRAWFORM REVISION: 10 MAY 2014
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
UNCLASSIFIED//FOR OFFICIAL USE ONLY
FIRE PROTECTION
CHIEF ENG/ARCH
BRANCH MGR
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
03/07/19
0%
S
UBM
IT
TAL
N O
T F O
R C
O
NSTRU
CTIO
N
NAVFAC SE
NAS JACKSONVILLE, FL
VETERINARY CLINIC
NS GUANTANAMO BAY, CUBA
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C L A
S S
IF
IE
D
F O
R O
F F
IC
IA
L U
S E
O N
L Y
U N
C L A
S S
IF
IE
D
F O
R O
F F
IC
IA
L U
S E
O N
L Y Stanley
Consultants INC.
/6
/2
:3
:5
P M
C
U s e rs \h a ll_ c \ D o c u m e n ts \B
L D
G -0
-1
-A h a ll_ c .r v t
1/4" = 1'-0"
A-660
15930331
W O
R K
IN
G
D O
G T
R E
A T
M E
N T
F A
C
IL
IT
Y
R E
P L
A C
E M
E N
T
F
IN
IS
H
S C
H E
D U
L E
G U
A N
T A
N A
M O
B A
Y , C
U B
A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
15126019
CBH CBH PLZ
U .S
N
A V
A L
S T
A T
IO
N
FINISH SCHEDULE
ROOM NO ROOM NAME
FLOOR BASE WALL CEILING
REMARKSMATERIAL COLOR MATERIAL COLOR
NORTH EAST SOUTH WEST
MATERIAL COLORMATERIAL COLOR MATERIAL COLOR MATERIAL COLOR MATERIAL COLOR
A01 OFFICE, FOOD INSPECTORS RT RT3 RB RB2 GPT PT1 GPT PT1 GPT PT1 GPT PT3 AT AT1 8
A02 CONFERENCE ROOM / BREAKROOM RT RT2 RB RB2 GPT PT2 GPT PT1 GPT PT2 GPT PT1 AT AT1 8
A03 OFFICE, NCOIC RT RT1 RB RB2 GPT PT1 GPT PT1 GPT PT1 GPT PT3 AT AT1 8
A04 KITCHENETTE RT RT1,2,3 RB RB1 GPT PT2 GPT PT2 GPT - - - GPT - - - AT AT1 5,7
A05 OFFICE, OIC RT RT1 RB RB2 GPT PT1 GPT PT1 GPT PT1 GPT PT3 AT AT1 8
A06 LOCKER/CHANGING ROOM, STAFF CT CT1,2 CTB CTB1 GCT CT3,4,5 GCT CT3,4,5 GCT CT3,4,5 GCT CT3,4 GPT PT6 1
A07 VET TECH RT RT3 RB RB2 GPT PT1 GPT PT1 GPT PT1 GPT PT3 AT AT1 8
A09 RECEPTION RT RT1 RB RB1 GPT PT2 GPT PT1 GPT PT1 GPT PT2 AT AT1 8
A10 TOILET, PUBLIC CT CT1 CTB CTB1 GCT CT3,4,5 GCT CT3,4 GCT CT3,4 GCT CT3,4,5 GPT PT6
A12 EXAM / TREATMENT ROOM ER ER1 IR IR1 GEP PT4 GEP PT5 GEP PT4 GEP PT4 AT AT2 5
A13 LOBBY / WAITING RT RT1,2,3 RB RB1 GPT PT2 GPT PT2 GPT PT1 GPT PT1 AT AT1 2,4,7
A13A VESTIBULE RT RT1,2,3 RB RB1 GPT PT1 GPT PT1 GPT PT1 GPT PT1 AT AT1 7
A14 EXAM / TREATMENT, POA ER ER1 IR IR1 GEP PT4 GEP PT4 GEP PT4 GEP PT5 AT AT2 5
A17 PHARMACY ER ER1 IR IR1 GEP PT4 GEP PT4 GEP PT4 GEP PT4 GEP PT7
A19 LABORATORY ER ER1 IR IR1 GEP PT5 GEP PT4 GEP PT4 GEP PT4 GEP PT7
A20 INSTRUMENT PREP ER ER1 IR IR1 - - - - - - GEP PT5 GEP PT5 GEP PT5 AT AT2
A21 OPERATING ROOM ER ER1 IR IR1 GEP PT4 GEP PT4 GEP PT4 GEP PT4 GEP PT7
A22 IMAGING ER ER1 IR IR1 GEL PT5 GEL PT5 GEL PT5 GEL PT5 GEP PT7
A24 TOILET, STAFF CT CT1 CTB CTB1 GCT CT3,4 GCT CT3,4 GCT CT3,4 GCT CT3,4 GPT PT6
A25 KENNELS LG ANIMALS ER ER1 IR IR1 BEP PT4,AP BEP PT4,AP BEP PT4,AP BEP PT4,AP AT AT3 6
A26 JANITOR CLOSET SCONC - - - RB RB1 GEP PT4 GCT CT3 GCT CT3 GEP PT4 GPT PT6
A27 LAUNDRY ROOM ER ER1 IR IR1 GEP PT4 GEP PT4 GEP PT4 GEP PT4 GPT PT6
A28 STORAGE, EQUIPMENT ER ER1 IR IR1 GPT PT1 GPT PT1 GPT PT1 GPT PT1 AT AT1
A29 UTILITY, SOILED ER ER1 IR IR1 GEP PT4 GEP PT4 GEP PT4 GEP PT4 AT AT2
A30 MWD EXAM / ISO HOLD ER ER1 IR IR1 GEP PT5 GEP PT4 GEP PT4 GEP PT4 AT AT2
A31 COMM SCCS - - - RB RB1 GPT PT1 GPT PT1 GPT PT1 GPT PT1 EXP - - -
A33 HOLDING, SM ANIMALS ER ER1 IR IR1 BEP PT4,AP BEP PT4,AP BEP PT4,AP BEP PT4,AP AT AT3 6
AC1 CORRIDOR RT RT1,2,3 RB RB1 GPT PT2 GPT PT1 GPT PT1 GPT PT1 AT AT1 7
AC2 CORRIDOR RT RT1,2,3 RB RB1 GPT PT1 GPT PT2 - - - - - - GPT PT1 AT AT1 7
AC3 CORRIDOR RT RT1,2,3 RB RB1 GPT PT2,WP1 GPT PT2 GPT PT1 GPT PT1 AT AT1 2,7
AC4 CORRIDOR RT RT1,2,3 RB RB1 GPT PT2 GPT PT2 - - - - - - GPT PT2 AT AT1 7
AC5 CORRIDOR ER ER1 IR IR1 GEP PT4 GEP PT4 GEP PT5 GEP PT4 AT AT2
AC6 RECEIVING / STAGING AREA ER ER1 IR IR1 GEP PT4 GEP PT4 GEP PT4 GEP PT4 AT AT2
AC6A FOOD PREP ER ER1 IR IR1 GEP PT4 - - - - - - - - - - - - GEP PT4 AT AT2
AC7 ANTE-ROOM RT RT1 RB RB1 GPT PT1 BPT PT1 GPT PT1 GPT PT1 GPT PT6
AC8 CORRIDOR ER ER1 IR IR1 - - - - - - GEP PT5 GEP PT5 GEP PT5 AT AT1
B01 MECHANICAL SCONC - - - RB RB2 GPT PT1 GPT PT1 GPT PT1 GPT PT1 EXP - - -
B02 ELECTRICAL SCONC - - - RB RB2 GPT PT1 GPT PT1 GPT PT1 GPT PT1 EXP - - -
NOT TO SCALE
TAB 5.
Color Design Legend
FLOOR
CT1 DAL TILE
PRODUCT: PORTFOLIO
SIZE: 12"X24"
COLOR: PF03 FANGO
GROUT: CUSTOM BUILDING PRODUCTS, 541 WALNUT
INSTALL: RUNNING BOND
CT2 DAL TILE
PRODUCT: PORTFOLIO
SIZE: 2"X2" (12"X24" MOSAIC SHEET)
COLOR: PF03 FANGO
GROUT: CUSTOM BUILDING PRODUCTS, 541 WALNUT
RT1 NORA
PRODUCT: NORAMENT
PATTERN: ARAGO 3118
SIZE: 20" X 40"
THICKNESS: 3.5 mm
COLOR: 5178 CALM
COLD WELD: 2930
RT2 NORA
PRODUCT: NORAMENT
PATTERN: ARAGO 3118
SIZE: 20" X 40"
THICKNESS: 3.5 mm
COLOR: 5180 SERENE
COLD WELD: 2930
RT3 NORA
PRODUCT: NORAMENT
PATTERN: ARAGO 3118
SIZE: 20" X 40"
THICKNESS 3.5mm
COLOR: 5179 TRANQUIL
COLD WELD: 2930
ER1 STONHARD
PRODUCT: STONTEC UTF
COLOR: SHENANDOAH BUFF, LARGE FLAKE
BASE
CTB1 DAL TILE
PRODUCT: PORTFOLIO
SIZE: 6"X12", P-36C9-T
COLOR: PF07 CREAM
GROUT: CUSTOM BUILDING PRODUCTS, 541 WALNUT
RB1 NORA
PRODUCT: SANITARY BASE
SERIES: 6", ART 817
COLOR: 2930 WINDFLOWER
COLD WELD: 2930
RB2 NORA
PRODUCT: WALL BASE
SERIES: 4", ART 820
COLOR: 6232 LIGHT GREY
IR1 REFER TO ER1
1. ACOUSTICAL
PANELS: (AP) ARMSTRONG
PRODUCT: 3154 OPTIMA WALL PANELS
FINISH: DURABRITE
COLOR: WHITE
SIZE: 4' X 8' (TRIM TO 3' X 8')
TRIM: C CHANNEL 3107
H CHANNEL 3108
2. INTERIOR DOORS: VT INDUSTRIES
PRODUCT: PLAIN SLICED WHITE BIRCH
STAIN: RAVINE, RA07
3. HOLLOW METAL
FRAMES: SHERWIN WILLIAMS
COLOR: 7017 DORIAN GRAY
GLOSS LEVEL: G5 (SEMI GLOSS)
4. MILLWORK: VERTICAL SURFACES (PL1)
PIONITE
COLOR: LOVE LETTERS AW300-SD
FINISH: SUEDE
EDGE BAND: 3MM PVC, CHARTER
INDUSTRIES - W1500, GREY
COUNTER TOP AND VERTICAL PANEL (SS1)
WILSONART
COLOR: CHILLED EARTH
5. WINDOW SHADES: (A6309)
MANUFACTURER: MECHOSHADE
PRODCUT: ECOVEIL SHEER, 3% OPEN
COLOR: 6754 STONE
6. SIGNAGE: 2/90 SIGN SYSTEM
MODEL: SLIDE ESSENTIALS, MODULAR
END CAP FINISH: 152 NICKEL
VINYL COLOR: 712 TAUPE GREY, 708 SOFT WHITE
INSERT: PAPER
COPY STYLE: HMC HELVETICA, MEDIUM
7. WALL PROTECTION:
CORNER GUARD: (CG1)
PRODUCT: INPRO 3" FLANGE, 4' HIGH
MODEL: 150 SURFACE MOUNT, 90 DEGREE
COLOR: SHARKSKIN
RIGID SHEET (WP1)
PRODUCT: INPRO 0.040" RIGID SHEET GOODS
COLOR: SHARKSKIN
BUMPER RAIL: (BR1)
PRODUCT: INPRO
MODEL: 500 WALL GUARD
COLOR: SHARKSKIN
WALLS
CT3 DAL TILE
PRODUCT: PORTFOLIO
SIZE: 6"X24"
COLOR: PF07 CREAM
GROUT: CUSTOM BUILDING PRODUCTS, 541 WALNUT
CT4 DAL TILE
PRODUCT: PORTFOLIO
SIZE: 3"X12" P-43C9, BULLNOSE
COLOR: PF07 CREAM
GROUT: CUSTOM BUILDING PRODUCTS, 541 WALNUT
CT5 FLORIDA TILE
PRODUCT: NEXA IRON STACK
SIZE: 12"X12" MOSAIC SHEET
COLOR: 34819/M1x4STK
GROUT: CUSTOME BUILDING PRODUCTS, 541 WALNUT
PT1 SHERWIN WILLIAMS
COLOR: 9173 SHITAKE
GLOSS LEVEL: G3 (EGGSHELL)
PT2 SHERWIN WILLIAMS
COLOR: 9148 SMOKY AZURITE
GLOSS LEVEL: G3 (EGGSHELL)
PT3 SHERWIN WILLIAMS
COLOR: 2855 SYCAMORE TAN
GLOSS LEVEL: G3 (EGGSHELL)
PT4 SHERWIN WILLIAMS
COLOR: 9173 SHITAKE
GLOSS LEVEL: EP/G5 (SEMI GLOSS)
PT5 SHERWIN WILLIAMS
COLOR: 9148 SMOKY AZURITE
GLOSS LEVEL: EP/G5 (SEMI GLOSS)
CELING
AT1 ARMSTRONG
PRODUCT: ULTIMA BEVELED TEGULAR
SIZE: 24"X24"
COLOR: WHITE
GRID: 15/16"
AT2 ARMSTRONG
PRODUCT: CLEAN ROOM VL NON PERFORATED
SIZE: 24"X24"
COLOR: WHITE
GRID: PRELUDE PLUS XL, 15/16"
AT3 ARMSTRONG
PRODUCT: CERAMAGUARD FINE FISSURED
SIZE: 24"X24"
COLOR: WHITE
GRID: PRELUDE PLUS (G90) XL, 15/16"
PT6 SHERWIN WILLIAMS
COLOR: 7005 PURE WHITE
GLOSS LEVEL: G1 (FLAT)
PT7 SHERWIN WILLIAMS
COLOR: 7005 PURE WHITE
GLOSS LEVEL: EP/G5 (SEMI GLOSS)
1. CMU1
MANUFACTURER: BLOCK USA
PRODUCT: 8" SPLIT FACE CMU
COLOR: MARKET SQUARE MARBLE
CMU2
MANUFACTURER: BLOCK USA
PRODUCT: 8" SMOOTH FACE CMU
COLOR: MARKET SQUARE MARBLE
2. ROOF - ALUMINUM PANEL STANDING SEAM
MANUFACTURER: BERRIDGE
COLOR: TERRA-COTTA
3. FRAMING SYSTEM - ALUMINUM AT WINDOWS AND ENTRANCES
MANUFACTURER: KANWEER
FINISH: LIGHT SATIN
4. FACIA, SOFFITS & DOWNSPOUTS
MATERIAL: PRE-FINISHED ALUMINUM
COLOR: WHITE
5. EXPOSED STEEL BEAMS AND COLUMNS:
PRODUCT: SHERWIN WILLIAMS
COLOR: MATCH KAWNEER BONE WHITE
GLOSS LEVEL: G5 (SEMI GLOSS)
6. EXPOSED CONCRETE BEAMS
COLOR : RUBBED CONCRETE FINISH
MATCH SPLIT FACE CMU
7. STOREFRONT DOORS
MANUFACTURER: KAWNEER
MATERIAL: ALUMINUM
COLOR: TERRA COTTA METALLIC
8. STEEL DOORS
PRODUCT: SHERWIN WILLIAMS
COLOR: 6342 SPICY HUE
9. DOOR FRAMES
PRODUCT: SHERWIN WILLIAMS
COLOR: MATCH KAWNEER BONE WHITE
10. LOUVER
MATERIAL: PRE-FINISHED ALUMINUM
COLOR: WHITE
11. PRE-FINISHED DETACHED CANOPY
MATERIAL: PRE-FINISHED ALUMINUM
COLOR: WHITE
12. GLASS: CLEAR
NOTE:
MANUFACTURER REFERENCES NOTED PROVIDE BASIS OF DESIGN FOR
MATERIALS, COLORS, AND PATTERN ONLY. PRODUCTS BY OTHER
MANUFACTURERS MAY BE ACCEPTABLE SUBJECT TO PROVIDING AN
ACCEPTABLE MATCH AND EQUAL COMPLYING REQUIREMENTS OF THE
SPECIFICATIONS.
FINISH SCHEDULE COLOR LEGEND MISCELLANEOUS INTERIOR FINISHES MISCELLANEOUS EXTERIOR FINISHES
A
B
C
D
1 2 3 4
1 2 3 4
A
B
C
D
IP
T
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
SCALE:
PROJECT NO:
CONSTR CONTR NO:
NAVFAC DRAWING NO:
SHEET: OF
DRAWFORM REVISION: 10 MAY 2014
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
UNCLASSIFIED//FOR OFFICIAL USE ONLY
FIRE PROTECTION
CHIEF ENG/ARCH
BRANCH MGR
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
03/07/19
0%
S
UBM
IT
TAL
N O
T F O
R C
O
NSTRU
CTIO
N
NAVFAC SE
NAS JACKSONVILLE, FL
VETERINARY CLINIC
NS GUANTANAMO BAY, CUBA
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C L A
S S
IF
IE
D
F O
R O
F F
IC
IA
L U
S E
O N
L Y
U N
C L A
S S
IF
IE
D
F O
R O
F F
IC
IA
L U
S E
O N
L Y Stanley
Consultants INC.
/6
/2
:3
:5
P M
C
U s e rs \h a ll_ c \ D o c u m e n ts \B
L D
G -0
-1
-A h a ll_ c .r v t
12" = 1'-0"
A-661
15930331
W O
R K
IN
G
D O
G T
R E
A T
M E
N T
F A
C
IL
IT
Y
R E
P L
A C
E M
E N
T
F
IN
IS
H
L E
G E
N D
G U
A N
T A
N A
M O
B A
Y , C
U B
A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
15126020
CBH CBH PLZ
U .S
N
A V
A L
S T
A T
IO
N
NOT TO SCALE
TAB 6.
Interior Finish Plan
FINISH PLAN LEGEND
RUBBER TILE RT1 - CALM
RUBBER TILE RT2 - SERENE
RUBBER TILE RT3 - TRANQUIL
DENOTES WALL FINISH APPLICATION
DENOTES WALL PROTECTION (WP1)
APPLICATION
GENERAL NOTES:
1. SEE SHEET A-660 FOR FINISH LEGEND.
2. FLOOR MATERIALS AND/OR PATTERNS
ARE SHOWN FOR ROOMS WITH
PATTERNS ONLY. REFER TO FINISH
SCHEDULE FOR FLOOR MATERIAL
APPLICATIONS.
MWD EXAM /
ISO HOLD
A30
LAUNDRY
ROOM
A27
LINEN, CLEAN
A27A
UTILITY, SOILED
A29
OFFICE, OIC
A05
OFFICE, NCOIC
A03
VET TECH
A07
RECEPTION
A09
LOBBY /
WAITING
A13
EXAM /
TREATMENT,
POA
A14
EXAM /
TREATMENT
ROOM
A12
TOILET, PUBLIC
A10
IMAGING
A22
LOCKER/CHANGING
ROOM, STAFF
A06
STORAGE,
EQUIPMENT
A28
OFFICE, FOOD
INSPECTORS
A01
CONFERENCE
ROOM /
BREAKROOM
A02
VESTIBULE
A13A
KITCHENETTE
A04
PHARMACY
A17
INSTRUMENT
PREP
A20
OPERATING
ROOM
A21
TOILET, STAFF
A24
KENNELS LG
ANIMALS
A25
JANITOR
CLOSET
A26
HOLDING, SM
ANIMALS
A33
COMM
A31
MECHANICAL
B01
FOOD PREP
AC6A
ELECTRICAL
B02
CORRIDOR
AC1
CORRIDOR
AC4
CORRIDOR
AC8
CORRIDOR
AC5
CORRIDOR
AC3
CORRIDOR
AC2
ANTE-ROOM
AC7
P T
PT2PT2
P T
PT2
PT5 PT5
PT5
P T
PT5
P T
WP1
WP1
WP1
WP1
LABORATORY
A19
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
MOUNT 3' X 8' ACOUSTICAL PANELS (AP)
HORIZONTAL, 6 FEET AFF USING H & C CHANNEL TRIM
SS1
SS1
SS1
KEY PLAN
PLAN
NORTH
1A
1B
A
B
C
D
1 2 3 4
1 2 3 4
A
B
C
D
IP
T
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
SCALE:
PROJECT NO:
CONSTR CONTR NO:
NAVFAC DRAWING NO:
SHEET: OF
DRAWFORM REVISION: 10 MAY 2014
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
UNCLASSIFIED//FOR OFFICIAL USE ONLY
FIRE PROTECTION
CHIEF ENG/ARCH
BRANCH MGR
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
03/07/19
0%
S
UBM
IT
TAL
N O
T F O
R C
O
NSTRU
CTIO
N
2' 4' 8'
SCALE: 1/4"=1'-0"
A1
NAVFAC SE
NAS JACKSONVILLE, FL
VETERINARY CLINIC
NS GUANTANAMO BAY, CUBA
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C L A
S S
IF
IE
D
F O
R O
F F
IC
IA
L U
S E
O N
L Y
U N
C L A
S S
IF
IE
D
F O
R O
F F
IC
IA
L U
S E
O N
L Y Stanley
Consultants INC.
/6
/2
:3
:5
P M
C
U s e rs \h a ll_ c \ D o c u m e n ts \B
L D
G -0
-1
-A h a ll_ c .r v t
1/4" = 1'-0"
SCALE: 1/4" = 1'-0"
AF111
15930331
W O
R K
IN
G
D O
G T
R E
A T
M E
N T
F A
C
IL
IT
Y
R E
P L
A C
E M
E N
T
IN
T
E R
IO
R
F
IN
IS
H
P L A
N
G U
A N
T A
N A
M O
B A
Y , C
U B
A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
15126024
CBH CBH AMJ
INTERIOR FINISH PLAN
U .S
N
A V
A L
S T
A T
IO
N
17170
| WORKING DOG TREATMENT FACILITY REPLACEMENT SID VOLUME I COVER |
| TABLE OF CONTENTS |
| TAB 1. NARRATIVE |
| TAB 2. EXTERIOR ELEVATIONS & EXTERIOR FINISHES |
| TAB 3. ARCHITECTURAL FLOOR PLAN |
| TAB 4. FINISH SCHEDULE |
| TAB 5. COLOR DESIGN LEGEND |
| TAB 6. INTERIOR FINISH PLAN |