9. NSGB WDTF - FINAL SUBMITTAL SID_VOL_I_BUNDLED - FIO.pdf

PDF 2 MB Posted

Attached to
Veterinary Clinic IO Project - Guantanamo Bay
Solicitation number
W9127S22Q6004
Issued by

About this file

This is a special notice for an upcoming solicitation to provide initial outfitting services for a veterinary clinic at Naval Station Guantanamo Bay, Cuba. The U.S. Army Corps of Engineers Little Rock District intends to issue a request for quote set aside for small businesses only, with a NAICS code of 337127 and size standard of 500 employees. The estimated contract value is between $1 million and $3 million, with an estimated proposal due date of August 31, 2022. The simplified acquisition procedures of FAR Part 13 will be used in conjunction with commercial items procedures of FAR Part 12. No site visit is scheduled for the solicitation. ProjectNet will accept questions from August 3 to August 15, 2022 regarding draft documents attached to this notice, which are subject to change prior to issuance of the solicitation. The OFB goal date for this project is December 31, 2023.

View the file

Other files

File Type Posted
22. Facility Related Control Systems Overlay_FINAL (FOUO).pdf PDF
7. NSGB WDTF - FINAL DWGS SIGNED gov.pdf PDF
17. Example Generic ICS Med-COI Boundary Diagram v4-1.pdf PDF
13. GTMO WDTF Existing Inventory (G) 7 Apr 2022.xlsx XLSX spreadsheet
19. FRCS-VRA Ver 2.0.docx DOCX document
2. NSGB WDTF Haul Route_USNH to Landfill 15 Mar 22.pdf PDF
6. NSGB WDTF - BASIS OF DESIGN - FIO MAY 2021.pdf PDF
24. Refrigerator Monitoring Systems.pdf PDF
20. DHA MDE Categorization Memo.pdf PDF
14. DHA FRCS Baseline Categorization Memorandum-1 October 2020 (1).pdf PDF
9. NSGB WDTF - FINAL SUBMITTAL SID_VOL_II_BUNDLED - FIO.pdf PDF
16. DHA System-Level Continuous Monitoring Plan 23MAY2018.xlsx XLSX spreadsheet
11. NSGB WDTF Construction Schedule 03 Mar 22.pdf PDF
3 Standard Notices (UEI PIEE NIST) For Industry.docx DOCX document
16. DHA System-Level Continuous Monitoring Plan 23MAY2018.pdf PDF
0. SOW-FY22 Guantanamo Bay Veterinary Clinic IOT-18 Jul 22.docx DOCX document
25. Audio Video Conferencing.pdf PDF
1. NSGB WDTF Haul Route_Port to USNH 15 Mar 22.pdf PDF
18. FRCS FAT SAT Checklist.pdf PDF
IO Eval Criteria GTMO WDTF.docx DOCX document
8. NSGB WDTF - Artwork Placement Plan - 01 JAN 19.pdf PDF
15. Draft DHA PM Standard Isolation Architecture for Cybersecurity of FRCS.DOCX DOCX document
00. FY22 NSGB WDTF_Div 00_CLIN Schedule_USACE.xlsx XLSX spreadsheet
23. Patient Monitoring and Telemetry System.pdf PDF
21. PIA Processes and Procedures.docx DOCX document
5. Guantanamo WDTF IO Project Status Report (PSR) 5 Apr 22.xlsx XLSX spreadsheet
10. NSGB WDTF - FINAL SUBMITTAL CID VOL1_AND_VOL2 - FIO 07 MAR 19.pdf PDF
12. NSGB WDTF - Medical Equipment - BASIS FOR BID - RPIE Removed 04 Apr 22.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Working Dog Treatment

Facility Replacement

100% Design Submittal Contract: N62450-14-D-0025 Task Order: N6945018F0872

Structural Interior Design (SID)

Volume I of II

US Naval Station Guantanamo Bay Guantanamo Bay, Cuba 7 March 2019

GeriGarami Text Box

FOR INFORMATION ONLY

WORKING DOG TREATMENT FACILITY REPLACEMENT MARCH 2019

TABLE OF CONTENTS

WORKING DOG TREATMENT FACILITY REPLACEMENT

US NAVAL STATION

GUANTANAMO BAY, CUBA

STRUCTURAL INTERIOR DESIGN (SID)

WORKING DOG TREATMENT FACILITY REPLACEMENT

US NAVAL STATION

GUANTANAMO BAY, CUBA

A/E Contract Number: N62450-14-D-0025 Delivery Order Number: P-89839 (FY19)

SS&A Project Number: 2018-013

TABLE OF CONTENTS

VOLUME I OF II

Narrative 1

Exterior Elevations, Exterior Finishes 2

Architectural Floor Plans 3

Finish Schedule 4

Color Design Legend 5

Interior Finish Plan 6

VOLUME II OF II

Interior Building Finishes 7

TAB 1.

Narrative

Section 2 – Interior Design Narrative

N62450-14-D-0025 | TASK ORDER: N6945018F0872 Working Dog Treatment Facility Replacement 2-1 NS Guantanamo Bay, Cuba

Section 2

Interior Design Narrative

2.1 Interior Partitions and Finishes

Typical interior partitions will be constructed of minimum 20-gauge, steel studs with 5/8” gypsum board on both sides at non-patient areas. All gypsum board will be mold resistant. At patient areas, interior partitions will be constructed of painted CMU or 20-gauge steel studs with clay tile over cement board on both sides. The large animal kennels will have 6” CMU or 4” CMU veneer walls for durability. All wall construction details will comply with applicable codes and standards. The partitions around the Imaging Room will be lined with

1/16” lead lining in accordance with the Physicist Report. See Appendix J for Physicist Report.

Interior doors will primarily be stained solid core wood doors with door armor where required.

Based on the Physicist Report, the Imaging Room will have a steel door. Lead lining at the door will not be required.

2.2 Materials Palette

All finishes are permanent in nature. Interior wall finishes include painted gypsum wallboard, gypsum wallboard with a latex epoxy coating, concrete block with a latex epoxy coating for kennel areas, and ceramic wall tile installed over cement backer board in wet areas. Washable, waterproof acoustical wall panels will be installed in the animal holding areas at six feet above the finished floor. Ceilings will be a combination of suspended acoustical panels, exposed structure, and painted gypsum wallboard. Flooring materials will be a combination of rubber tile, epoxy flooring, sealed concrete, and through color porcelain tile in wet areas. Rubber base will be used in conjunction with rubber tile and sealed concrete floors. Epoxy floors will have an integral base. Through color porcelain tile cove base will be used in conjunction with through color porcelain tile floors. Rubber tile with rubber base is proposed for the lobby area and administrative spaces. Epoxy flooring is proposed for the treatment areas and animal holding areas.

GeriGarami F I O

TAB 2.

Exterior Elevations & Exterior Finishes

A B B.7 B.9 C

'-0

SPLIT FACE CMU (CMU1)

STANDING SEAM ALUMINUM ROOF

PRE-FINISHED

ALUMINUM FASCIA

TOP OF MASONRY

12'-0"

0'-0"

FINISHED FLOOR

PRE-FINISHED ALUMINUM

DOWNSPOUT - TYPICAL

PRE-FINISHED

ALUMINUM GUTTER

ALUMINUM STOREFRONT

FRAMING SYSTEM

SPLIT FACE CMU (CMU1)

SPANDREL GLASS PANEL IN

STOREFRONT

ALUMINUM STOREFRONT

FRAMING SYSTEM

PAINTED 5"X5" TUBE STEEL COLUMN

PAINTED 8"X6" STRUCTURAL TUBE STEEL BEAM

ALUM. STOREFRONT

FRAMING SYSTEM

PAINTED STEEL

ORNAMENTAL

BRACKET

CONCRETE

SPLASH BLOCK

- TYPICAL

BREAK METAL

TRIM

CJCJ

REEL MACHINE (SEE PLUMBING)

REEL MACHINE

(SEE

PLUMBING)

K3420 K3420

BUILDING NUMBER SIGN

SMOOTH FACE CMU

(CMU2) AT TOP OF COURSE

SEE ELECTRICAL

(TYP.)

B AB.7B.9C

'-0

SPLIT FACE CMU (CMU1)

STANDING SEAM ALUMINUM ROOF

PRE-FINISHED ALUMINUM

DOWNSPOUT - TYPICAL

PRE-FINISHED

ALUMINUM FASCIA

PRE-FINSIHED ALUMINUM GUTTER

TOP OF MASONRY

12'-0"

0'-0"

FINISHED FLOOR

ALUMINUM STOREFRONT

SYSTEM

CONCRETE SPLASH

BLOCK -TYPICAL PRE-FABRICATED ALUM. CANOPY

AT EXTERIOR CAGE WASH AREA

WALL MOUNTED LIGHT FIXTURE

(SEE LIGHTING PLAN)

BREAK METAL TRIIM

CJ CJ CJCJ

REEL MACHINE (SEE PLUMBING)SLEEVE THROUGH CMU MASONRY GRIND CMU SMOOTH

AND SEAL AND PRE-FINISHED ALUM. ESCUTCHEON FOR

ANESTHESIA GAS DISPOSAL VENT (SEE PLUMBING)

REEL MACHINE

(SEE PLUMBING)

K3420

K3420

SMOOTH FACE CMU

(CMU2) AT TOP OF

COURSE

POWER EXHAUST FAN

POWER EXHAUST FAN

SEE ELECTRICAL

(TYP.)

LEGEND

CONTROL JOINT, SEE DET. A4/A-301CJ

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

IP

T

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

DRAWFORM REVISION: 10 MAY 2014

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

UNCLASSIFIED//FOR OFFICIAL USE ONLY

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

03/07/19

0%

S

UBM

IT

TAL

N O

T F O

R C

O

NSTRU

CTIO

N

3' 6' 12'

SCALE: 3/16"=1'-0"

NAVFAC SE

NAS JACKSONVILLE, FL

VETERINARY CLINIC

NS GUANTANAMO BAY, CUBA

UNCLASSIFIED//FOR OFFICIAL USE ONLY

U N

C L A

S S

IF

IE

D

F O

R O

F F

IC

IA

L U

S E

O N

L Y

U N

C L A

S S

IF

IE

D

F O

R O

F F

IC

IA

L U

S E

O N

L Y Stanley

Consultants INC.

/6

/2

:3

:5

P M

C

U s e rs \h a ll_ c \ D o c u m e n ts \B

L D

G -0

-1

-A h a ll_ c .r v t

As indicated

A-201

15930331

W O

R K

IN

G

D O

G T

R E

A T

M E

N T

F A

C

IL

IT

Y

R E

P L

A C

E M

E N

T

E X

T E

R

IO

R E

L E

V A

T

IO

N S

G U

A N

T A

N A

M O

B A

Y , C

U B

A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S

O U

T H

E A

S T

15125996

PLZ VDS PLZ

U .S

N

A V

A L

S T

A T

IO

N

SCALE: 3/16" = 1'-0"

SOUTH ELEVATION

C1 REF: A-111

SCALE: 3/16" = 1'-0"

NORTH ELEVATION

A1 REF: A-111

1. SEE SIGN TYPE XBA FOR BUILDING NUMBER

SIGN ON SHEET AF112. COORDINATE LOCATION

OF BUILDING NUMBER SIGN WITH GOVERMENT'S

REPRESENTATIVE BEFORE INSTALLING BUILDING

NUMBER SIGNS.

2. SEE MISCELLANEOUS EXTERIOR FINISHES ON

SHEET A-661 FOR LISTING OF EXTERIOR FINISH

MATERIALS AND COLORS.

GENERAL NOTES

3/16" = 1'-0"

2 3 41

'-0

SPLIT FACE CMU (CMU1)

STANDING SEAM ALUMINUM ROOF

PRE-FINISHED

ALUMINUM FASCIA

TOP OF MASONRY

12'-0"

0'-0"

FINISHED FLOOR

ALUMINUM STOREFRONT

FRAMING SYSTEM

PRE-FINISHED ALUMINUM

GUTTER

PAINTED STEEL ORNAMENTAL BRACKET

PRE-FINISHED ALUMINUM GUTTER

SPANDREL GLASS IN STOREFRONT

SYSTEM

PAINTED 5"X5" TUBE STEEL COLUMN

ALUMINUM STOREFRONT

FRAMING SYSTEM

PAINTED 8"X6" TUBE STEEL BEAM

PRE-FINISHED ALUMINUM

DOWNSPOUT - TYPICAL

CONCRETE SPLASH

BLOCK - TYPICAL

PRE-FABRICATED ALUM. CANOPY

AT EXTERIOR CAGE WASH AREA

WALL MOUNTED

LIGHT FIXTURE

(SEE LIGHTING PLAN)

CJCJCJ

REEL MACHINE

& HOSE BIBB

(SEE

PLUMBING)

REEL MACHINE & HOSE BIB (SEE

PLUMBING)

K3420

K3420

SMOOTH FACE CMU

(CMU2) AT TOP OF COURSE

POWER EXHAUST FAN

POWER EXHAUST FAN

SEE ELECTRICAL

(TYP.)

4 3 2 1

'-0

3' -4

6'

-8

6' -0

4'

-0

STANDING SEAM ALUMINUM ROOF

PRE-FINISHED

ALUMINUM

DOWNSPOUT

PRE-FINISHED ALUMINUM GUTTER

TOP OF MASONRY

12'-0"

0'-0"

FINISHED FLOOR

PRE-FINISHED

ALUMINUM FASCIA

PRE-FINISHED ALUMINUM

GUTTER

PAINTED STEEL ORNAMENTAL BRACKET

SPANDREL GLASS PANEL IN

STOREFRONT SYSTEM

PAINTED 5"x5" TUBE STEEL COLUMN

ALUMINUM STOREFRONT

FRAMING SYSTEM

OPENING IN

CMU END

WALL - CMU

BEYOND

WALL MOUNTED LIGHT FIXTURE

(SEE LIGHTING PLAN)

PAINTED 8"x6" TUBE STEEL BEAM

CONCRETE SPLASH BLOCK

-TYPICAL

ALUMINUM

STOREFRONT

FRAMING SYSTEM

CJ CJ

REEL MACHINE

& HOSE BIBB

(SEE

PLUMBING)

BUILDING NUMBER SIGN

K3420

SPLIT FACE CMU (CMU1)

SMOOTH FACE CMU (CMU2)

AT TOP OF COURSE

4" CONCRETE

CAP

SEE FP

SEE ELECTRICAL

(TYP.)

C5

A-610

LEGEND

CONTROL JOINT, SEE DET. A4/A-301CJ

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

IP

T

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

DRAWFORM REVISION: 10 MAY 2014

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

UNCLASSIFIED//FOR OFFICIAL USE ONLY

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

03/07/19

0%

S

UBM

IT

TAL

N O

T F O

R C

O

NSTRU

CTIO

N

3' 6' 12'

SCALE: 3/16"=1'-0"

NAVFAC SE

NAS JACKSONVILLE, FL

VETERINARY CLINIC

NS GUANTANAMO BAY, CUBA

UNCLASSIFIED//FOR OFFICIAL USE ONLY

U N

C L A

S S

IF

IE

D

F O

R O

F F

IC

IA

L U

S E

O N

L Y

U N

C L A

S S

IF

IE

D

F O

R O

F F

IC

IA

L U

S E

O N

L Y Stanley

Consultants INC.

/6

/2

:3

:5

P M

C

U s e rs \h a ll_ c \ D o c u m e n ts \B

L D

G -0

-1

-A h a ll_ c .r v t

As indicated

A-202

15930331

W O

R K

IN

G

D O

G T

R E

A T

M E

N T

F A

C

IL

IT

Y

R E

P L

A C

E M

E N

T

E X

T E

R

IO

R E

L E

V A

T

IO

N S

G U

A N

T A

N A

M O

B A

Y , C

U B

A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S

O U

T H

E A

S T

15125997

PLZ VDS PLZ

U .S

N

A V

A L

S T

A T

IO

N

SCALE: 3/16" = 1'-0"

EAST ELEVATION

C1 REF: A-111

SCALE: 3/16" = 1'-0"

WEST ELEVATION

A1 REF: A-111

1. SEE SIGN TYPE XBA FOR BUILDING NUMBER

SIGN ON SHEET AF112. COORDINATE LOCATION

OF BUILDING NUMBER SIGN WITH GOVERMENT'S

REPRESENTATIVE BEFORE INSTALLING BUILDING

NUMBER SIGNS.

2. SEE MISCELLANEOUS EXTERIOR FINISHES ON

SHEET A-661 FOR LISTING OF EXTERIOR FINISH

MATERIALS AND COLORS.

GENERAL NOTES

3/16" = 1'-0"

WORKING DOG TREATMENT FACILITY REPLACEMENT MARCH 2019

EXTERIOR BUILDING FINISHES

WORKING DOG TREATMENT FACILITY REPLACEMENT

US NAVAL STATION

GUANTANAMO BAY, CUBA

EXPOSED STEEL BEAMS AND COLUMNS

PRODUCT: SHERWIN WILLIAMS

COLOR: MATCH KAWNEER BONE WHITE

GLOSS LEVEL: G5 (SEMI GLOSS)

STOREFRONT DOORS

MANUFACTURERE: KAWNEER

MATERIAL: ALUMINUM

COLOR: TERRA COTTA METALLIC

STEEL DOORS

PRODUCT: SHERWIN WILLIAMS

COLOR: 6342 SPICY HUE

DOOR FRAMES

PRODUCT: SHERWIN WILLIAMS

COLOR: MATCH KAWNEER BONE WHITE

TAB 3.

Architectural Floor Plans

DIMENSION TO FACE OF STEEL

STUD OR MASONRY WALLS. REFER

TO WALL TYPES FOR STUD WALL

THICKNESS UNLESS SPECIFICALLY

NOTED OTHERWISE

PLAN LEGEND

ROOMNAME

3' - 0"

EXTERIOR WALL

INTERIOR WALL CONSTRUCTION

ONE HOUR FIRE BARRIER

SMOKE PARTITION

(NON-FIRE RATED)

ROOM NAME AND NUMBER

SMOKE BARRIER

(NON-FIRE RATED)

ONE HOUR FIRE AND SMOKE BARRIER

A B C

B.7 B.9

CAGE WASH

PAD

25' - 8" 8' - 0" 52' - 0"

2'

3'

25' - 8" 8' - 0" 52' - 0"

85' - 8"

2'

6' - 4"

MWD EXAM /

ISO HOLD

A30

LAUNDRY

ROOM

A27

LINEN, CLEAN

A27A

UTILITY, SOILED

A29

OFFICE, OIC

A05

OFFICE, NCOIC

A03

VET TECH

VET TECH

A07 STORAGE,

FILES COPY / OFFICE

SUPPLY

STORAGE,

CONSUMABLES

RECEPTION

A09

LOBBY /

WAITING

A13

EXAM /

TREATMENT,

POA

A14

EXAM /

TREATMENT

ROOM

A12

TOILET, PUBLIC

A10

IMAGING

A22

LOCKER/CHANGING

ROOM, STAFF

A06

STORAGE,

EQUIPMENT

A28

OFFICE, FOOD

INSPECTORS

A01

CONFERENCE

ROOM /

BREAKROOM

A02

VESTIBULE

A13A

KITCHENETTE

A04

PHARMACY

A17

CENTRAL

MEDICAL

SUPPLY

LABORATORY

A19

STORAGE,

FREEZER

SCRUB / GOWN

AREA

INSTRUMENT

PREP

A20

OPERATING

ROOM

A21

TOILET, STAFF

A24

KENNELS LG

ANIMALS

A25

JANITOR

CLOSET

A26

HOLDING, SM

ANIMALS

A33 RECEIVING /

STAGING AREA

AC6

COMM

A31

CAGE WASH

MECHANICAL

B01

FOOD PREP

AC6A

ELECTRICAL

B02

CORRIDOR

AC1

CORRIDOR

AC4

CORRIDOR

AC8

CORRIDOR

AC5

CORRIDOR

AC3

CORRIDOR

AC2

ANTE-ROOM

AC7

0"

6'

A-201

A1

A-202C1

A-201

C1

A-202 A1

DETACHED

CANOPY

ABOVE

A4

A-310

A3

A-313

A1

A-311

Sim

A3

A-312 A2

A-310

A2

A-310

A4

A-310

LEADING EDGE OF LANDING

A1

A-301

A1

A-301

C1

A-301

C1

A-301

8' - 0" 6' - 0"

A-160

A1

A-543

A2

A-543

A1

KEY PLAN

PLAN

NORTH

1A

1B

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

IP

T

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

DRAWFORM REVISION: 10 MAY 2014

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

UNCLASSIFIED//FOR OFFICIAL USE ONLY

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

03/07/19

0%

S

UBM

IT

TAL

N O

T F O

R C

O

NSTRU

CTIO

N

3' 6' 12'

SCALE: 3/16"=1'-0"

A1

NAVFAC SE

NAS JACKSONVILLE, FL

VETERINARY CLINIC

NS GUANTANAMO BAY, CUBA

UNCLASSIFIED//FOR OFFICIAL USE ONLY

U N

C L A

S S

IF

IE

D

F O

R O

F F

IC

IA

L U

S E

O N

L Y

U N

C L A

S S

IF

IE

D

F O

R O

F F

IC

IA

L U

S E

O N

L Y Stanley

Consultants INC.

/6

/2

:3

:4

P M

C

U s e rs \h a ll_ c \ D o c u m e n ts \B

L D

G -0

-1

-A h a ll_ c .r v t

3/16" = 1'-0"

SCALE: 3/16" = 1'-0"

A-111

15930331

W O

R K

IN

G

D O

G T

R E

A T

M E

N T

F A

C

IL

IT

Y

R E

P L

A C

E M

E N

T

F L O

O R

P L A

N

C O

M P

O S

IT

E

G U

A N

T A

N A

M O

B A

Y , C

U B

A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S

O U

T H

E A

S T

15125990

PLZ PLZ PLZ

FLOOR PLAN - COMPOSITE

U .S

N

A V

A L

S T

A T

IO

N

36 171

A

MWD EXAM /

ISO HOLD

A30

LAUNDRY

ROOM

A27

UTILITY, SOILED

A29

OFFICE, OIC

A05

OFFICE, NCOIC

A03

VET TECH

A07

RECEPTION

A09

LOBBY /

WAITING

A13

EXAM /

TREATMENT,

POA

A14

EXAM /

TREATMENT

ROOM

A12

TOILET, PUBLIC

A10

IMAGING

A22

LOCKER/CHANGING

ROOM, STAFF

A06

STORAGE,

EQUIPMENT

A28

OFFICE, FOOD

INSPECTORS

A01

CONFERENCE

ROOM /

BREAKROOM

A02

VESTIBULE

A13A

KITCHENETTE

A04

PHARMACY

A17

LABORATORY

A19

INSTRUMENT

PREP

A20

OPERATING

ROOM

A21

TOILET, STAFF

A24

KENNELS LG

ANIMALS

A25

JANITOR

CLOSET

A26

HOLDING, SM

ANIMALS

A33

RECEIVING /

STAGING AREA

AC6

COMM

A31

FOOD PREP

AC6A

CORRIDOR

AC1

CORRIDOR

AC4

CORRIDOR

AC8

CORRIDOR

AC5

CORRIDOR

AC3

CORRIDOR

AC2

ANTE-ROOM

AC7

A-430D1

B C

B.7 B.9

A-410

A1

A-430 D2

A-430

A-430

B1

A-430

A-430 B2

A-430 A1

A-430A2

A-410

C1

A17A21A27

A24A26

A25 A33

A29

AC6

A31

AC7A

AC7

AC5

A14A

A14A12

A12A

A10

AC4

A22 A28

AC2

A30

A02

A01 A03 A05 A07

A06

A09

AC1

A13B

A13A

A-430 A3

85' - 8"

8' - 8"

M.O.

5' - 4" 3' - 4"

M.O.

5' - 4" 6' - 8"

M.O.

5' - 4" 3' - 4"

M.O.

5' - 4" 6' - 8"

M.O.

5' - 4" 3' - 4"

M.O.

5' - 4" 7' - 8" 8' - 0" 6' - 0"

2'

M .O

2'

2'

M .O

5'

2'

M .O

2'

2'

M .O

2'

M .O

4'

4" 4' - 4" 3' - 4" 2' - 8"

M.O.

2' - 8"

3'

8" M

.O

2'

5'

M .O

3'

9'

6'

5'

4'

M .O

5'

6'

M .O

5'

4'

9'

6' - 4"

2'

11' - 5 3/4" 4' - 5" 10' - 6 5/8" 10' - 6 5/8" 11' - 5" 10' - 7 1/4" 8' - 9 1/8" 4' - 0" 13' - 10 5/8"

17' - 7 5/8" 12' - 8 3/4" 13' - 11 5/8" 11' - 4"11' - 5 3/4" 6' - 9 3/8" 11' - 8 7/8"

5' - 1 1/4" 7' - 1" 6' - 11" 1' - 0" 7' - 8 5/8" 10' - 5 3/4" 5' - 1 1/4" 10' - 11 3/8" 9' - 5" 10' - 5"

3' - 0"

3'

/8

5'

/4

5'

/4

8'

/2

5'

/4

6'

/8

9'

/4

7'

/8

7'

/8

3'

/4

4'

/4

8'

1/ 8"

8'

/8

4'

/8

5'

5/ 8"

6'

/8

5'

/4

6'

/8

ALIGN

A

LI

G N

W4 W4 W4 W4 W4 W4

W4

W3

W3

W3

W3

W3

W6

W5

W6

W4

W4

W8

W7 10A

8B

8B

8C

8C

8B

8A

888B

8B

7 8

2B

8A

8C

2C

2A

2A 2C

2D

10B

10A

10B

4A

3A

2A

2A

8B

8B

5'

5"

M .O

3'

A5075

A5090

A5145

M7490

X4600

A5145

A5145A5145

A5145 A5145

A5145 A5145

A

A

UR221

A5145A5220 A5145

A5075

A5082 P3000

UA511

UA510

A5080

U A

A5075

CS150

P1965

CD040

CD040

CD040

A1080

K

K3420

A

UA510 UA511

A

A5077

K3420

P9050 A1067

A5075

A5082

P3000

A5145

A5116 A1067 P3000

A5082

A5075

CT020

A5210P

CB020

CD040

CD040

U A

U A

1 A

A

C S

A5077

P5040 A5075

A5030 A5110

A5170 A5205 P9050

A5075

A1067

P3000

A5082

A5090

A5116

A5017

F

A5145 A5145 A5145

A5145

C D

A5145

CD040

M7405

M7405

K3420

A5077

UA510

UA511

A5145

M7405

A5080

CD040

C03P0

CS150

M1803

P2000

A5116

A5119

A5080UA511

P2000

P4700 A5075 A5135

CT050

CS230

A5075

A5080

CD040

A

A

P8710

C D

0P

C D

CD040

CQ030M

F3050

A5075

A5077

UA510

UA511

A5145

M7405

A5080

CD040

C03P0

CS150

M1803

M1803

A5080

A5080

A5075

UV003

UV003

UV003

UV003

UV003

UV003

UV003

A5080

4' - 10"

4' - 0"

C T

C

P

CT050

A5150

A5150

C T

P2451

CT020

C04F0

CT050

C04F0

CT020CT020

P9050

A5200

A5119

CT020

X2125

X3150

A5119

A5200

P2451

CS150

CT020

C04F0B

A5090 A5200

A-411

C1

A6309 A6309 A6309 A6309 A6309A6309

A6309

A6309

A6309

A6309

A6309

A6309

CG2

CG1 CG1

CG1

CG1

CG1

CG1

CG1

CG1

BR1

BR1 BR1BR1 BR1BR1

BR1

BR1

BR1

BR1

BR1

BR1BR1

BR1

BR1

ALIGN

FEC

A-630

D2

A-630

D2

B R

BR1

W9

D3

D4

FEC

A-430B3

P6500

A-430

A4

A-430D2

MIR.

A-430 B5

SIM.

C5

A-610

A5145

F

A5075

CG1

C03P0

C03P0B

A5080 A5075

CG1

F3050

F3025

C

G

C

G

U V

U V

P2451

UA003

UT030

F3025 F3050 F3050

A

FE

2'

.0

0°

DIMENSION TO FACE OF STEEL

STUD OR MASONRY WALLS. REFER

TO WALL TYPES FOR STUD WALL

THICKNESS UNLESS SPECIFICALLY

NOTED OTHERWISE

PLAN LEGEND

ROOMNAME

3' - 0"

EXTERIOR WALL

INTERIOR WALL CONSTRUCTION

ONE HOUR FIRE BARRIER

SMOKE PARTITION

(NON-FIRE RATED)

ROOM NAME AND NUMBER

GENERAL NOTES:

1. SEE A-680 SERIES SHEETS FOR

EQUIPMENT IDENTIFICATION AND

EQUIPMENT SCHEDULE.

2. ALL DIMENSIONS ARE FROM FACE OF

STUD TO FACE OF STUD OR FACE OF CMU

BLOCK TYPICALLY. DIMENSIONS NOTED

AS "CLEAR" ARE FACE TO FINISHED WALL

TO FACE OF FINISHED WALL.

SMOKE BARRIER

(NON-FIRE RATED)

A1066

FEC

JSN NUMBER, SEE EQUIPMENT

SHEETS FOR IDENTIFICATION

FIRE EXTINGUISHER IN CABINET,

SEMI RECESSED

(SEE DETAIL B1/A-543)

DOOR NUMBER SYMBOL

SEE DOOR SCHEDULE ON SHEETS

A-610 THROUGH A-616

FE FIRE EXTINGUISHER, WALL HUNG

1A

CG1, CG2

CORNER GUARD TYPE

(SEE DETAIL C5/A-510 & 4 /A-542)

WALL TYPE SYMBOL,

SEE A-550 SERIES SHEETS FOR

WALL TYPES

W1

WINDOW TYPE SYMBOL,

SEE SHEET A-620

BR1 BUMPER RAIL (SEE DETAIL

B5/A-542)

CJ-1 CONTROL JOINT,

SEE DETAIL A-542

LOUVER TYPE SYMBOL,

SEE SHEET A-620

L1

KEY PLAN

PLAN

NORTH

1A

1B

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

IP

T

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

DRAWFORM REVISION: 10 MAY 2014

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

UNCLASSIFIED//FOR OFFICIAL USE ONLY

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

03/07/19

0%

S

UBM

IT

TAL

N O

T F O

R C

O

NSTRU

CTIO

N

2' 4' 8'

SCALE: 1/4"=1'-0"

A1

NAVFAC SE

NAS JACKSONVILLE, FL

VETERINARY CLINIC

NS GUANTANAMO BAY, CUBA

UNCLASSIFIED//FOR OFFICIAL USE ONLY

U N

C L A

S S

IF

IE

D

F O

R O

F F

IC

IA

L U

S E

O N

L Y

U N

C L A

S S

IF

IE

D

F O

R O

F F

IC

IA

L U

S E

O N

L Y Stanley

Consultants INC.

/6

/2

:3

:4

P M

C

U s e rs \h a ll_ c \ D o c u m e n ts \B

L D

G -0

-1

-A h a ll_ c .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

A-112

15930331

W O

R K

IN

G

D O

G T

R E

A T

M E

N T

F A

C

IL

IT

Y

R E

P L

A C

E M

E N

T

F L O

O R

P L A

N

B L O

C K

A

G U

A N

T A

N A

M O

B A

Y , C

U B

A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S

O U

T H

E A

S T

15125991

PLZ PLZ PLZ

FLOOR PLAN - BLOCK A

U .S

N

A V

A L

S T

A T

IO

N

17137

A

CAGE WASH

MECHANICAL

B01

ELECTRICAL

B02

B C

CAGE WASH

PAD

DETACHED PRE-

FABRICATED CANOPY

ABOVE

B02

B01

2'

M .O

4'

M .O

6'

4" 4' - 4" 3' - 4" 2' - 8"

M.O.

2' - 8"

3'

8" M

.O

2'

5'

9' - 6"

7'

/2

3'

/4

W3

W3

K3420

L1

2'

M .O

4'

FE

2'

.0

0°

DIMENSION TO FACE OF STEEL

STUD OR MASONRY WALLS. REFER

TO WALL TYPES FOR STUD WALL

THICKNESS UNLESS SPECIFICALLY

NOTED OTHERWISE

PLAN LEGEND

ROOMNAME

3' - 0"

EXTERIOR WALL

INTERIOR WALL CONSTRUCTION

ONE HOUR FIRE BARRIER

SMOKE PARTITION

(NON-FIRE RATED)

ROOM NAME AND NUMBER

GENERAL NOTES:

1. SEE A-680 SERIES SHEETS FOR

EQUIPMENT IDENTIFICATION AND

EQUIPMENT SCHEDULE.

2. ALL DIMENSIONS ARE FROM FACE OF

STUD TO FACE OF STUD OR FACE OF CMU

BLOCK TYPICALLY. DIMENSIONS NOTED

AS "CLEAR" ARE FACE TO FINISHED WALL

TO FACE OF FINISHED WALL.

SMOKE BARRIER

(NON-FIRE RATED)

A1066

FEC

JSN NUMBER, SEE EQUIPMENT

SHEETS FOR IDENTIFICATION

FIRE EXTINGUISHER IN CABINET,

SEMI RECESSED

(SEE DETAIL B1/A-543)

DOOR NUMBER SYMBOL

SEE DOOR SCHEDULE ON SHEETS

A-610 THROUGH A-616

FE FIRE EXTINGUISHER, WALL HUNG

1A

CG1, CG2

CORNER GUARD TYPE

(SEE DETAIL C5/A-510 & 4 /A-542)

WALL TYPE SYMBOL,

SEE A-550 SERIES SHEETS FOR

WALL TYPES

W1

WINDOW TYPE SYMBOL,

SEE SHEET A-620

BR1 BUMPER RAIL (SEE DETAIL

B5/A-542)

CJ-1 CONTROL JOINT,

SEE DETAIL A-542

LOUVER TYPE SYMBOL,

SEE SHEET A-620

L1

KEY PLAN

PLAN

NORTH

1A

1B

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

IP

T

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

DRAWFORM REVISION: 10 MAY 2014

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

UNCLASSIFIED//FOR OFFICIAL USE ONLY

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

03/07/19

0%

S

UBM

IT

TAL

N O

T F O

R C

O

NSTRU

CTIO

N

2' 4' 8'

SCALE: 1/4"=1'-0"

A1

NAVFAC SE

NAS JACKSONVILLE, FL

VETERINARY CLINIC

NS GUANTANAMO BAY, CUBA

UNCLASSIFIED//FOR OFFICIAL USE ONLY

U N

C L A

S S

IF

IE

D

F O

R O

F F

IC

IA

L U

S E

O N

L Y

U N

C L A

S S

IF

IE

D

F O

R O

F F

IC

IA

L U

S E

O N

L Y Stanley

Consultants INC.

/6

/2

:3

:4

P M

C

U s e rs \h a ll_ c \ D o c u m e n ts \B

L D

G -0

-1

-A h a ll_ c .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

A-113

15930331

W O

R K

IN

G

D O

G T

R E

A T

M E

N T

F A

C

IL

IT

Y

R E

P L

A C

E M

E N

T

F L O

O R

P L A

N

B L O

C K

B

G U

A N

T A

N A

M O

B A

Y , C

U B

A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S

O U

T H

E A

S T

15125992

PLZ PLZ PLZ

FLOOR PLAN - BLOCK B

U .S

N

A V

A L

S T

A T

IO

N

17138

TAB 4.

Finish Schedule

1. MANUFACTURER REFERENCES NOTED PROVIDE BASIS OF DESIGN FOR MATERIALS,

COLORS, AND PATTERN ONLY. PRODUCTS BY OTHER MANUFACTURERS MAY BE

ACCEPTABLE SUBJECT TO PROVIDING AN ACCEPTABLE MATCH AND EQUAL

COMPLYING REQUIREMENTS OF THE SPECIFICATIONS.

2. THE FINISH SCHEDULE LISTS THE ROOMS IN THE PROJECT. IT LISTS ROOM

NUMBERS WHICH ARE SHOWN ON THE ARCHITECTURAL FLOOR PLANS CONTAINED

IN THE A-100 SHEET SERIES.

3. SEE REFLECTED CEILING PLANS ON A-800 SERIES SHEETS FOR ALL CEILING

HEIGHTS AND CONFIGURATIONS.

4. SEE DETAIL A2/A-542 FOR INTREGAL BASE.

ABBREVIATIONS LEGEND

AP ACOUSTICAL WALL PANEL

AT ACOUSTICAL CEILING TILE

BEP CONCRETE BLOCK, EPOXY COATING

BPT CONCRETE BLOCK, PAINTED

CS SEALED CONCRETE

CT CERAMIC TILE

CTB CERAMIC TILE BASE

ER EPOXY RESIN

EXP EXPOSED

GEL GYPSUM WALLBOARD - EPOXY COATING,LEAD LINED

GEP GYPSUM WALLBOARD - EPOXY COATING

GPT GYPSUM WALLBOARD - PAINTED

GCT GYPSUM WALLBOARD - TILE

IR INTEGRAL EPOXY RESIN BASE

PL PLASTIC LAMINATE

PT PAINT

RB RESILIENT BASE

RT RUBBER TILE FLOORING

SCCS STATIC CONTROL CONCRETE SEALER

SCONC HARDENED AND SEALED CONCRETE

SS SOLID SURFACE

WP WALL PROTECTION

* SEE REMARKS COLUMN

FINISH SCHEDULE REMARKS

NOTE 1 PROVIDE CT2 WITHIN SHOWER FLOOR AREA.

NOTE 2 APPLY WALL PROTECTION (WP1) TO WALLS AT SCALE AND WATER COOLER.

SEE FINISH PLAN AF-111.

NOTE 4 PROVIDE SOLID SURFACE (SS1) TRANSACTION COUNTER, ADA HEIGHT AT

LOBBY RECEPTION. PROVIDE 1/2" THICK SOLID SURFACE PANEL AT START

OF WALL LEFT OF TRANSACTION COUNTER, UNDERNEATH AND TO END OF

WALL ON RIGHT. SEE FINISH PLAN AF-111 AND ELEVATION, SHEET A-250 FOR

LOCATION AND FINISH HEIGHT.

NOTE 5 CASEWORK TO BE PL1 AND SS1 FOR KITCHENETTE AND EXAM / TREATMENT

ROOMS.

NOTE 6 PROVIDE ACOUSTICAL WALL PANELS (AP) FOR LARGE ANIMAL KENNEL AND

SMALL ANIMAL HOLDING. SEE FINISH PLAN AF-111.

NOTE 7 PROVIDE COLD WELD INSTALLTION BETWEEN EACH TILE AND AT SANITARY

COVE BASE, BY MANUFACTURERS SPECIFICATION, FOR RUBBER TILES IN

VESTIBULE, WAITING AND CORRIODR.

NOTE 8 PROVIDE RUNNING BOND INSTALLATION WITH COLD WELD ONLY AT

SANITARY COVE BASE SEAM.

ROOM FINISH SCHEDULE GENERAL NOTES

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

IP

T

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

DRAWFORM REVISION: 10 MAY 2014

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

UNCLASSIFIED//FOR OFFICIAL USE ONLY

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

03/07/19

0%

S

UBM

IT

TAL

N O

T F O

R C

O

NSTRU

CTIO

N

NAVFAC SE

NAS JACKSONVILLE, FL

VETERINARY CLINIC

NS GUANTANAMO BAY, CUBA

UNCLASSIFIED//FOR OFFICIAL USE ONLY

U N

C L A

S S

IF

IE

D

F O

R O

F F

IC

IA

L U

S E

O N

L Y

U N

C L A

S S

IF

IE

D

F O

R O

F F

IC

IA

L U

S E

O N

L Y Stanley

Consultants INC.

/6

/2

:3

:5

P M

C

U s e rs \h a ll_ c \ D o c u m e n ts \B

L D

G -0

-1

-A h a ll_ c .r v t

1/4" = 1'-0"

A-660

15930331

W O

R K

IN

G

D O

G T

R E

A T

M E

N T

F A

C

IL

IT

Y

R E

P L

A C

E M

E N

T

F

IN

IS

H

S C

H E

D U

L E

G U

A N

T A

N A

M O

B A

Y , C

U B

A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S

O U

T H

E A

S T

15126019

CBH CBH PLZ

U .S

N

A V

A L

S T

A T

IO

N

FINISH SCHEDULE

ROOM NO ROOM NAME

FLOOR BASE WALL CEILING

REMARKSMATERIAL COLOR MATERIAL COLOR

NORTH EAST SOUTH WEST

MATERIAL COLORMATERIAL COLOR MATERIAL COLOR MATERIAL COLOR MATERIAL COLOR

A01 OFFICE, FOOD INSPECTORS RT RT3 RB RB2 GPT PT1 GPT PT1 GPT PT1 GPT PT3 AT AT1 8

A02 CONFERENCE ROOM / BREAKROOM RT RT2 RB RB2 GPT PT2 GPT PT1 GPT PT2 GPT PT1 AT AT1 8

A03 OFFICE, NCOIC RT RT1 RB RB2 GPT PT1 GPT PT1 GPT PT1 GPT PT3 AT AT1 8

A04 KITCHENETTE RT RT1,2,3 RB RB1 GPT PT2 GPT PT2 GPT - - - GPT - - - AT AT1 5,7

A05 OFFICE, OIC RT RT1 RB RB2 GPT PT1 GPT PT1 GPT PT1 GPT PT3 AT AT1 8

A06 LOCKER/CHANGING ROOM, STAFF CT CT1,2 CTB CTB1 GCT CT3,4,5 GCT CT3,4,5 GCT CT3,4,5 GCT CT3,4 GPT PT6 1

A07 VET TECH RT RT3 RB RB2 GPT PT1 GPT PT1 GPT PT1 GPT PT3 AT AT1 8

A09 RECEPTION RT RT1 RB RB1 GPT PT2 GPT PT1 GPT PT1 GPT PT2 AT AT1 8

A10 TOILET, PUBLIC CT CT1 CTB CTB1 GCT CT3,4,5 GCT CT3,4 GCT CT3,4 GCT CT3,4,5 GPT PT6

A12 EXAM / TREATMENT ROOM ER ER1 IR IR1 GEP PT4 GEP PT5 GEP PT4 GEP PT4 AT AT2 5

A13 LOBBY / WAITING RT RT1,2,3 RB RB1 GPT PT2 GPT PT2 GPT PT1 GPT PT1 AT AT1 2,4,7

A13A VESTIBULE RT RT1,2,3 RB RB1 GPT PT1 GPT PT1 GPT PT1 GPT PT1 AT AT1 7

A14 EXAM / TREATMENT, POA ER ER1 IR IR1 GEP PT4 GEP PT4 GEP PT4 GEP PT5 AT AT2 5

A17 PHARMACY ER ER1 IR IR1 GEP PT4 GEP PT4 GEP PT4 GEP PT4 GEP PT7

A19 LABORATORY ER ER1 IR IR1 GEP PT5 GEP PT4 GEP PT4 GEP PT4 GEP PT7

A20 INSTRUMENT PREP ER ER1 IR IR1 - - - - - - GEP PT5 GEP PT5 GEP PT5 AT AT2

A21 OPERATING ROOM ER ER1 IR IR1 GEP PT4 GEP PT4 GEP PT4 GEP PT4 GEP PT7

A22 IMAGING ER ER1 IR IR1 GEL PT5 GEL PT5 GEL PT5 GEL PT5 GEP PT7

A24 TOILET, STAFF CT CT1 CTB CTB1 GCT CT3,4 GCT CT3,4 GCT CT3,4 GCT CT3,4 GPT PT6

A25 KENNELS LG ANIMALS ER ER1 IR IR1 BEP PT4,AP BEP PT4,AP BEP PT4,AP BEP PT4,AP AT AT3 6

A26 JANITOR CLOSET SCONC - - - RB RB1 GEP PT4 GCT CT3 GCT CT3 GEP PT4 GPT PT6

A27 LAUNDRY ROOM ER ER1 IR IR1 GEP PT4 GEP PT4 GEP PT4 GEP PT4 GPT PT6

A28 STORAGE, EQUIPMENT ER ER1 IR IR1 GPT PT1 GPT PT1 GPT PT1 GPT PT1 AT AT1

A29 UTILITY, SOILED ER ER1 IR IR1 GEP PT4 GEP PT4 GEP PT4 GEP PT4 AT AT2

A30 MWD EXAM / ISO HOLD ER ER1 IR IR1 GEP PT5 GEP PT4 GEP PT4 GEP PT4 AT AT2

A31 COMM SCCS - - - RB RB1 GPT PT1 GPT PT1 GPT PT1 GPT PT1 EXP - - -

A33 HOLDING, SM ANIMALS ER ER1 IR IR1 BEP PT4,AP BEP PT4,AP BEP PT4,AP BEP PT4,AP AT AT3 6

AC1 CORRIDOR RT RT1,2,3 RB RB1 GPT PT2 GPT PT1 GPT PT1 GPT PT1 AT AT1 7

AC2 CORRIDOR RT RT1,2,3 RB RB1 GPT PT1 GPT PT2 - - - - - - GPT PT1 AT AT1 7

AC3 CORRIDOR RT RT1,2,3 RB RB1 GPT PT2,WP1 GPT PT2 GPT PT1 GPT PT1 AT AT1 2,7

AC4 CORRIDOR RT RT1,2,3 RB RB1 GPT PT2 GPT PT2 - - - - - - GPT PT2 AT AT1 7

AC5 CORRIDOR ER ER1 IR IR1 GEP PT4 GEP PT4 GEP PT5 GEP PT4 AT AT2

AC6 RECEIVING / STAGING AREA ER ER1 IR IR1 GEP PT4 GEP PT4 GEP PT4 GEP PT4 AT AT2

AC6A FOOD PREP ER ER1 IR IR1 GEP PT4 - - - - - - - - - - - - GEP PT4 AT AT2

AC7 ANTE-ROOM RT RT1 RB RB1 GPT PT1 BPT PT1 GPT PT1 GPT PT1 GPT PT6

AC8 CORRIDOR ER ER1 IR IR1 - - - - - - GEP PT5 GEP PT5 GEP PT5 AT AT1

B01 MECHANICAL SCONC - - - RB RB2 GPT PT1 GPT PT1 GPT PT1 GPT PT1 EXP - - -

B02 ELECTRICAL SCONC - - - RB RB2 GPT PT1 GPT PT1 GPT PT1 GPT PT1 EXP - - -

NOT TO SCALE

TAB 5.

Color Design Legend

FLOOR

CT1 DAL TILE

PRODUCT: PORTFOLIO

SIZE: 12"X24"

COLOR: PF03 FANGO

GROUT: CUSTOM BUILDING PRODUCTS, 541 WALNUT

INSTALL: RUNNING BOND

CT2 DAL TILE

PRODUCT: PORTFOLIO

SIZE: 2"X2" (12"X24" MOSAIC SHEET)

COLOR: PF03 FANGO

GROUT: CUSTOM BUILDING PRODUCTS, 541 WALNUT

RT1 NORA

PRODUCT: NORAMENT

PATTERN: ARAGO 3118

SIZE: 20" X 40"

THICKNESS: 3.5 mm

COLOR: 5178 CALM

COLD WELD: 2930

RT2 NORA

PRODUCT: NORAMENT

PATTERN: ARAGO 3118

SIZE: 20" X 40"

THICKNESS: 3.5 mm

COLOR: 5180 SERENE

COLD WELD: 2930

RT3 NORA

PRODUCT: NORAMENT

PATTERN: ARAGO 3118

SIZE: 20" X 40"

THICKNESS 3.5mm

COLOR: 5179 TRANQUIL

COLD WELD: 2930

ER1 STONHARD

PRODUCT: STONTEC UTF

COLOR: SHENANDOAH BUFF, LARGE FLAKE

BASE

CTB1 DAL TILE

PRODUCT: PORTFOLIO

SIZE: 6"X12", P-36C9-T

COLOR: PF07 CREAM

GROUT: CUSTOM BUILDING PRODUCTS, 541 WALNUT

RB1 NORA

PRODUCT: SANITARY BASE

SERIES: 6", ART 817

COLOR: 2930 WINDFLOWER

COLD WELD: 2930

RB2 NORA

PRODUCT: WALL BASE

SERIES: 4", ART 820

COLOR: 6232 LIGHT GREY

IR1 REFER TO ER1

1. ACOUSTICAL

PANELS: (AP) ARMSTRONG

PRODUCT: 3154 OPTIMA WALL PANELS

FINISH: DURABRITE

COLOR: WHITE

SIZE: 4' X 8' (TRIM TO 3' X 8')

TRIM: C CHANNEL 3107

H CHANNEL 3108

2. INTERIOR DOORS: VT INDUSTRIES

PRODUCT: PLAIN SLICED WHITE BIRCH

STAIN: RAVINE, RA07

3. HOLLOW METAL

FRAMES: SHERWIN WILLIAMS

COLOR: 7017 DORIAN GRAY

GLOSS LEVEL: G5 (SEMI GLOSS)

4. MILLWORK: VERTICAL SURFACES (PL1)

PIONITE

COLOR: LOVE LETTERS AW300-SD

FINISH: SUEDE

EDGE BAND: 3MM PVC, CHARTER

INDUSTRIES - W1500, GREY

COUNTER TOP AND VERTICAL PANEL (SS1)

WILSONART

COLOR: CHILLED EARTH

5. WINDOW SHADES: (A6309)

MANUFACTURER: MECHOSHADE

PRODCUT: ECOVEIL SHEER, 3% OPEN

COLOR: 6754 STONE

6. SIGNAGE: 2/90 SIGN SYSTEM

MODEL: SLIDE ESSENTIALS, MODULAR

END CAP FINISH: 152 NICKEL

VINYL COLOR: 712 TAUPE GREY, 708 SOFT WHITE

INSERT: PAPER

COPY STYLE: HMC HELVETICA, MEDIUM

7. WALL PROTECTION:

CORNER GUARD: (CG1)

PRODUCT: INPRO 3" FLANGE, 4' HIGH

MODEL: 150 SURFACE MOUNT, 90 DEGREE

COLOR: SHARKSKIN

RIGID SHEET (WP1)

PRODUCT: INPRO 0.040" RIGID SHEET GOODS

COLOR: SHARKSKIN

BUMPER RAIL: (BR1)

PRODUCT: INPRO

MODEL: 500 WALL GUARD

COLOR: SHARKSKIN

WALLS

CT3 DAL TILE

PRODUCT: PORTFOLIO

SIZE: 6"X24"

COLOR: PF07 CREAM

GROUT: CUSTOM BUILDING PRODUCTS, 541 WALNUT

CT4 DAL TILE

PRODUCT: PORTFOLIO

SIZE: 3"X12" P-43C9, BULLNOSE

COLOR: PF07 CREAM

GROUT: CUSTOM BUILDING PRODUCTS, 541 WALNUT

CT5 FLORIDA TILE

PRODUCT: NEXA IRON STACK

SIZE: 12"X12" MOSAIC SHEET

COLOR: 34819/M1x4STK

GROUT: CUSTOME BUILDING PRODUCTS, 541 WALNUT

PT1 SHERWIN WILLIAMS

COLOR: 9173 SHITAKE

GLOSS LEVEL: G3 (EGGSHELL)

PT2 SHERWIN WILLIAMS

COLOR: 9148 SMOKY AZURITE

GLOSS LEVEL: G3 (EGGSHELL)

PT3 SHERWIN WILLIAMS

COLOR: 2855 SYCAMORE TAN

GLOSS LEVEL: G3 (EGGSHELL)

PT4 SHERWIN WILLIAMS

COLOR: 9173 SHITAKE

GLOSS LEVEL: EP/G5 (SEMI GLOSS)

PT5 SHERWIN WILLIAMS

COLOR: 9148 SMOKY AZURITE

GLOSS LEVEL: EP/G5 (SEMI GLOSS)

CELING

AT1 ARMSTRONG

PRODUCT: ULTIMA BEVELED TEGULAR

SIZE: 24"X24"

COLOR: WHITE

GRID: 15/16"

AT2 ARMSTRONG

PRODUCT: CLEAN ROOM VL NON PERFORATED

SIZE: 24"X24"

COLOR: WHITE

GRID: PRELUDE PLUS XL, 15/16"

AT3 ARMSTRONG

PRODUCT: CERAMAGUARD FINE FISSURED

SIZE: 24"X24"

COLOR: WHITE

GRID: PRELUDE PLUS (G90) XL, 15/16"

PT6 SHERWIN WILLIAMS

COLOR: 7005 PURE WHITE

GLOSS LEVEL: G1 (FLAT)

PT7 SHERWIN WILLIAMS

COLOR: 7005 PURE WHITE

GLOSS LEVEL: EP/G5 (SEMI GLOSS)

1. CMU1

MANUFACTURER: BLOCK USA

PRODUCT: 8" SPLIT FACE CMU

COLOR: MARKET SQUARE MARBLE

CMU2

MANUFACTURER: BLOCK USA

PRODUCT: 8" SMOOTH FACE CMU

COLOR: MARKET SQUARE MARBLE

2. ROOF - ALUMINUM PANEL STANDING SEAM

MANUFACTURER: BERRIDGE

COLOR: TERRA-COTTA

3. FRAMING SYSTEM - ALUMINUM AT WINDOWS AND ENTRANCES

MANUFACTURER: KANWEER

FINISH: LIGHT SATIN

4. FACIA, SOFFITS & DOWNSPOUTS

MATERIAL: PRE-FINISHED ALUMINUM

COLOR: WHITE

5. EXPOSED STEEL BEAMS AND COLUMNS:

PRODUCT: SHERWIN WILLIAMS

COLOR: MATCH KAWNEER BONE WHITE

GLOSS LEVEL: G5 (SEMI GLOSS)

6. EXPOSED CONCRETE BEAMS

COLOR : RUBBED CONCRETE FINISH

MATCH SPLIT FACE CMU

7. STOREFRONT DOORS

MANUFACTURER: KAWNEER

MATERIAL: ALUMINUM

COLOR: TERRA COTTA METALLIC

8. STEEL DOORS

PRODUCT: SHERWIN WILLIAMS

COLOR: 6342 SPICY HUE

9. DOOR FRAMES

PRODUCT: SHERWIN WILLIAMS

COLOR: MATCH KAWNEER BONE WHITE

10. LOUVER

MATERIAL: PRE-FINISHED ALUMINUM

COLOR: WHITE

11. PRE-FINISHED DETACHED CANOPY

MATERIAL: PRE-FINISHED ALUMINUM

COLOR: WHITE

12. GLASS: CLEAR

NOTE:

MANUFACTURER REFERENCES NOTED PROVIDE BASIS OF DESIGN FOR

MATERIALS, COLORS, AND PATTERN ONLY. PRODUCTS BY OTHER

MANUFACTURERS MAY BE ACCEPTABLE SUBJECT TO PROVIDING AN

ACCEPTABLE MATCH AND EQUAL COMPLYING REQUIREMENTS OF THE

SPECIFICATIONS.

FINISH SCHEDULE COLOR LEGEND MISCELLANEOUS INTERIOR FINISHES MISCELLANEOUS EXTERIOR FINISHES

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

IP

T

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

DRAWFORM REVISION: 10 MAY 2014

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

UNCLASSIFIED//FOR OFFICIAL USE ONLY

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

03/07/19

0%

S

UBM

IT

TAL

N O

T F O

R C

O

NSTRU

CTIO

N

NAVFAC SE

NAS JACKSONVILLE, FL

VETERINARY CLINIC

NS GUANTANAMO BAY, CUBA

UNCLASSIFIED//FOR OFFICIAL USE ONLY

U N

C L A

S S

IF

IE

D

F O

R O

F F

IC

IA

L U

S E

O N

L Y

U N

C L A

S S

IF

IE

D

F O

R O

F F

IC

IA

L U

S E

O N

L Y Stanley

Consultants INC.

/6

/2

:3

:5

P M

C

U s e rs \h a ll_ c \ D o c u m e n ts \B

L D

G -0

-1

-A h a ll_ c .r v t

12" = 1'-0"

A-661

15930331

W O

R K

IN

G

D O

G T

R E

A T

M E

N T

F A

C

IL

IT

Y

R E

P L

A C

E M

E N

T

F

IN

IS

H

L E

G E

N D

G U

A N

T A

N A

M O

B A

Y , C

U B

A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S

O U

T H

E A

S T

15126020

CBH CBH PLZ

U .S

N

A V

A L

S T

A T

IO

N

NOT TO SCALE

TAB 6.

Interior Finish Plan

FINISH PLAN LEGEND

RUBBER TILE RT1 - CALM

RUBBER TILE RT2 - SERENE

RUBBER TILE RT3 - TRANQUIL

DENOTES WALL FINISH APPLICATION

DENOTES WALL PROTECTION (WP1)

APPLICATION

GENERAL NOTES:

1. SEE SHEET A-660 FOR FINISH LEGEND.

2. FLOOR MATERIALS AND/OR PATTERNS

ARE SHOWN FOR ROOMS WITH

PATTERNS ONLY. REFER TO FINISH

SCHEDULE FOR FLOOR MATERIAL

APPLICATIONS.

MWD EXAM /

ISO HOLD

A30

LAUNDRY

ROOM

A27

LINEN, CLEAN

A27A

UTILITY, SOILED

A29

OFFICE, OIC

A05

OFFICE, NCOIC

A03

VET TECH

A07

RECEPTION

A09

LOBBY /

WAITING

A13

EXAM /

TREATMENT,

POA

A14

EXAM /

TREATMENT

ROOM

A12

TOILET, PUBLIC

A10

IMAGING

A22

LOCKER/CHANGING

ROOM, STAFF

A06

STORAGE,

EQUIPMENT

A28

OFFICE, FOOD

INSPECTORS

A01

CONFERENCE

ROOM /

BREAKROOM

A02

VESTIBULE

A13A

KITCHENETTE

A04

PHARMACY

A17

INSTRUMENT

PREP

A20

OPERATING

ROOM

A21

TOILET, STAFF

A24

KENNELS LG

ANIMALS

A25

JANITOR

CLOSET

A26

HOLDING, SM

ANIMALS

A33

COMM

A31

MECHANICAL

B01

FOOD PREP

AC6A

ELECTRICAL

B02

CORRIDOR

AC1

CORRIDOR

AC4

CORRIDOR

AC8

CORRIDOR

AC5

CORRIDOR

AC3

CORRIDOR

AC2

ANTE-ROOM

AC7

P T

PT2PT2

P T

PT2

PT5 PT5

PT5

P T

PT5

P T

WP1

WP1

WP1

WP1

LABORATORY

A19

AP

AP

AP

AP

AP

AP

AP

AP

AP

AP

MOUNT 3' X 8' ACOUSTICAL PANELS (AP)

HORIZONTAL, 6 FEET AFF USING H & C CHANNEL TRIM

SS1

SS1

SS1

KEY PLAN

PLAN

NORTH

1A

1B

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

IP

T

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

DRAWFORM REVISION: 10 MAY 2014

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

UNCLASSIFIED//FOR OFFICIAL USE ONLY

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

03/07/19

0%

S

UBM

IT

TAL

N O

T F O

R C

O

NSTRU

CTIO

N

2' 4' 8'

SCALE: 1/4"=1'-0"

A1

NAVFAC SE

NAS JACKSONVILLE, FL

VETERINARY CLINIC

NS GUANTANAMO BAY, CUBA

UNCLASSIFIED//FOR OFFICIAL USE ONLY

U N

C L A

S S

IF

IE

D

F O

R O

F F

IC

IA

L U

S E

O N

L Y

U N

C L A

S S

IF

IE

D

F O

R O

F F

IC

IA

L U

S E

O N

L Y Stanley

Consultants INC.

/6

/2

:3

:5

P M

C

U s e rs \h a ll_ c \ D o c u m e n ts \B

L D

G -0

-1

-A h a ll_ c .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

AF111

15930331

W O

R K

IN

G

D O

G T

R E

A T

M E

N T

F A

C

IL

IT

Y

R E

P L

A C

E M

E N

T

IN

T

E R

IO

R

F

IN

IS

H

P L A

N

G U

A N

T A

N A

M O

B A

Y , C

U B

A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S

O U

T H

E A

S T

15126024

CBH CBH AMJ

INTERIOR FINISH PLAN

U .S

N

A V

A L

S T

A T

IO

N

17170

WORKING DOG TREATMENT FACILITY REPLACEMENT SID VOLUME I COVER
TABLE OF CONTENTS
TAB 1. NARRATIVE
TAB 2. EXTERIOR ELEVATIONS & EXTERIOR FINISHES
TAB 3. ARCHITECTURAL FLOOR PLAN
TAB 4. FINISH SCHEDULE
TAB 5. COLOR DESIGN LEGEND
TAB 6. INTERIOR FINISH PLAN

File details come from the government source that posted it. Updated .