About this file

This is a restroom specification sheet for Provo City's Fort Utah Park Improvements project located at 200 North Geneva Road in Provo, Utah. The document provides detailed specifications for restroom facilities that are components of the broader park improvement initiative, which includes replacement parking lot curb and gutter, walkways, parking lot, and retaining wall construction. The specification sheet outlines the technical requirements, materials, dimensions, and construction standards for the restroom structures to be included in the project scope under RFB NO. PR2026001035.

The restroom specifications establish baseline requirements for bidders submitting proposals for the Site Structures & Furnishings category of the Fort Utah Park Improvements project. The document details construction materials, fixture specifications, accessibility requirements, and other relevant standards that restroom facilities must meet as part of the overall park improvement work. Bidders responding to the RFB must ensure their proposed restroom installations comply with all specifications outlined in this sheet, which serves as a binding technical standard for the project award and construction execution.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1 Restroom Standards

DescriptionBrandModelColorNotes
Hand Dryer /Surface MountExcel Dryers Inc.HO-IWWhiteAdd 1/8" Stainless plate under dryer
Foam Soap DispenserWaxie1250MLBlack
Toilet Paper 10" Twin Tissue DispenserProvided by OwnerDS-3040Smoke/Black
Bi Level Drinking Fountain Wall MountMurdockGYE24-RStainlessMake sure to have bottle filler.
Water ClosetAcorn1696-W-1StainlessMake sure to order carrier through the wall
UrinalAcorn1709HEUStainless
Celling HeaterDayton2YU47White
SinkAcorn1652LRBStainless
FaucetSloanEAF-300-PLG-CP-1.5GPM-AER-IQ-FCTPolished Crome
Mop SinkMUSTEE63MWhite24x24 mop sink or approved equal.
Mop FaucetMoan8230CromeTwo-Handle Service Sink Faucet.
Flush ValveSloan152 ESS 1.28-OR-3/4-LDIM-HWN/A
Mechanical Room LightsCooperFail-Safe HVSL4White
Wall LightsRABWP2XFU100/LCBSBronzePlease provide a photo cell for this.
Occupancy SensorAnyPlease provide a celling mounted occupancy sensor in each restroom
Diaper changing tableHorizontal fold down changing station250 lbs. minimum support capacity
MirrorSilver Flat Glass Mirror24" x 36" Tall
PartitionsHadrian PartitionsSolid plastic Headrail Braced Paisley 227
ADA Grab barsAny
LocksTrilogyDL400 / DL4500 Series
Roofing26 Guage metalTuff-RIB
Block8x16 CMUTBDTBDAll block is to be grouted solid.
Metal Doors and framesTBDTBDTBDOn doors should be 3'0"x7'0" with 2" side jams and 4" head to prevent block cuts.
WindowsN/A3/8" Sandblasted lexan with aluminum store front windows.
PAINT
Interior block walls first coatPPGSpeed hide block filler 6-15XL
Interior second coatPPGPitt Glaze WB epoxy SG 16-1510
Finish CoatPPGPitt Glaze WB epoxy SG 16-1510
Interior concrete floors first coatAmerlockEpoxy AK1
Finish CoatAmerlockEpoxy AK2
Exterior metal doors two coatsBenjamin MoreExterior Ultraspec Satin
Exterior Block Graffiti CoatingsProscoBlock Guard 2 Graffiti Control