This is a project specification document for Provo City's Fort Utah Park Improvements project located at 200 North Geneva Road in Provo, Utah, under RFB No. PR2026001035. The project scope encompasses construction of a four-room restroom facility as part of broader park improvements that include replacement parking lot curb and gutter, walkways, parking lot, and retaining wall. The restroom structure specifications indicate a multi-stall facility designed to serve park visitors, with the restroom component being one element within the larger site improvements requiring demolition, grading and excavation, electrical and lighting, concrete and hardscapes, asphalt, utility and drainage systems, site structures and furnishings, masonry, landscaping, and irrigation work.
The document provides detailed construction specifications and design requirements for the restroom facility to ensure it meets municipal standards and integrates appropriately with the overall park improvement project. Bidders responding to this RFB must address all specified work categories, with particular attention to the restroom facility construction quality and compliance with applicable building codes and accessibility requirements. The project represents a significant capital improvement to Fort Utah Park's infrastructure and amenities.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 5-6 RESTROOM SPEC SHEET.xlsx | XLSX spreadsheet | |
| 6-1 Fort Utah Park Construction 2026 RFB.pdf | ||
| 1-2 07-20-2026 FORT UTAH Bid Schedule.xlsx | XLSX spreadsheet | |
| 3-4 Fort Utah Park Specs Document.pdf | ||
| 2-3 260716 Fort Utah Park GBD PLANS Document.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET INDEX:
C: COVER
A-1: PLANS
A-2: ELEVATIONS AND SECTIONS
A-3: DETAILS
SD-0: STRUCTURAL NOTES
SD-1: STRUCTURAL DETAILS
PROVO BATHROOMS - QUAIL ORCHARD 4 BATH
C
SHEET
STAMP
PROJECT NO:
DATE:
SCALE:
DRAWN BY:
CHECKED BY:
26-007
2.23.26
CKC
CKC
D A
TE
RE
V
IS
IO
N
PR
O
V O
B A
TH
RO
O M
S
- Q
UA
IL
O
RC
HA
RD
B
A
TH
C O
V
ER
1/4" = 1'-0" (24"x36")
Caleb G:\PE Stamps\Orders\2023\110015 Chisten UT-Eng\110015 Chriten UT-Eng Final Model (1)
FC-1
FW-3
FC
-1
FW
-3
FC
-1
FW
-3
FC-1
FW-3
FC
-1
FW
-3
4" CONCRETE SLAB OVER
4" COMPACTED GRAVEL.
OPTIONAL REINFORCEMENT:
#3 BARS @ 18" O.C. EACH WAY
SD�1
T<P�
OR
SD�1
T<P�
SD�1
T<P�
OR
SD�1
T<P�
FC-1
FW-3
FC-1
FW-3
FC
-1
FW
-3
FOUNDATION PLAN
16'-8"
8" 3'-41
4" 8'-81 4" 3'-41
4" 75 8"
7' -3
5 8" 75 8"
'-1
1 2" 75 8"
7' -3
5 8"
'-8
6'
-8
'-8
8'-0 3 16"
8"
8'-0 3 16"
FLOOR PLAN
16'-8"
2'-33 4" 12'-01
2" 2'-33 4"
16'-8"
2'-33 4" 12'-01
2" 2'-33 4"
'-1
1 2"
15'-43 4"
7'-4 9 16" 75
8" 7'-4 9 16"
7' -3
5 8" 75 8"
'-1
1 2" 75 8"
7' -3
5 8"
30�0 30�0
30�0 30�0
�0 �0
D B
L
SEE DETAILS FOR ADA COMPLIANCE
D
UA
L
HE
IG
HT
S
TA
IN
LE
SS
ST
EE
L
D
RI
N
KI
N G
F O
UN
TA
IN
S
TOILET ROOM TOILET ROOM
TOILET ROOM TOILET ROOM
STORAGE
F.D. F.D.
F.D. F.D.
F.D.
A2
A2
A2
A2
G
FI
TIMING DEVICES FOR LIGHTS & HEATERS
ELECTRICAL PANEL
S
TO TIMING
DEVICE FOR
LIGHTS
TO TIMING
DEVICE FOR
HEATERS
TO TIMING
DEVICE FOR
HEATERS
TO TIMING
DEVICE FOR
LIGHTS
ELECTRICAL PLAN
SD�1
T<P�
S D
�1�
T< P
SD�1
T<P�
MW-1
MW-1
M W
-1
ML-1
M W
-1
ML-1
PRE-FAB ROOF TRUSSES @ 24" O.C. - (BY OTHERS - U.N.O.)
M W
-1
SD�1
T<P�
M L-
SD�1
M W
-1
MW-1
MW-1
ML-1 ML-1
M W
-1
ROOF PLAN
EXHAUST FAN
ELECTRICAL LEGEND
HIGH PRESSURE SODIUM SURFACE
MOUNTED LIGHT FIXTURE W/ LEXAN
COVER IN RESTROOMS & 2'X2'
FLOURESCENT LIGHT IN STORAGE ROOM
S DOUBLE POLE SWITCH
WALL MOUNTED PHOTO CELL HIGH
PRESSURE SODIUM TYPE LIGHT FIXTURE
GFI GFI OUTLET
- JUNCTION BOX
CEILING MOUNTED ELECTRIC HEATER
MARK
TYPICAL FOOTING SCHEDULE
REINFORCEMENT
FC-2
FS-1
FS-2
FS-3
FS-4
FS-5
(2) #4 BARS CONT. @ EQUAL SPACING
(3) #4 BARS EACH WAY @ EQUAL SPACING
(3) #4 BARS EACH WAY @ EQUAL SPACING
(4) #4 BARS EACH WAY @ EQUAL SPACING
(5) #5 BARS EACH WAY @ EQUAL SPACING
(5) #5 BARS EACH WAY @ EQUAL SPACING
WIDTH DEPTHLENGTH
18" 10"CONT.
24" 10"24" 30" 10"30" 36" 10"36" 42" 12"42" 48" 12"48"
FC-1 (2) #4 BARS CONT. @ EQUAL SPACING20" 10"CONT.
DESIG.
FOUNDATION WALL SCHEDULE
REINFORCEMENT
FW3
FW4
FW5
FW6
FW7
FW8
FW9
WIDTH HEIGHT
8" 8" 8" 8" 8" 8" 8"
36" (MAX)
48" (MAX)
60" (MAX)
72" (MAX)
84" (MAX)
96" (MAX)
108" (MAX)
#4 BARS @ 24" O.C.
VERTICAL HORIZONTAL
#4 BARS @ 24" O.C.
#4 BARS @ 24" O.C.
#4 BARS @ 24" O.C.
#4 BARS @ 16" O.C.
#4 BARS @ 24" O.C.
#4 BARS @ 24" O.C.
(3) #4 BARS EQ. SPACE
(4) #4 BARS EQ. SPACE
(4) #4 BARS EQ. SPACE
(5) #4 BARS EQ. SPACE
(6) #4 BARS EQ. SPACE
(6) #4 BARS EQ. SPACE
(7) #4 BARS EQ. SPACE
NOTES:
1� ALL HORIZONTAL CORNER LAP SPLICES TO BE A MINIMUM OF 24� FROM FOUNDATION WALL CORNER 2� REBAR AROUND OPENINGS - USE �2� HORIZONTAL BARS WITHIN 2� OF THE TOP OPENING EXTENDING
AT LEAST 24� PAST BOTH SIDES OF OPENING� USE �1� BAR WITHIN 2� OF BOTH SIDES OF OPENING�
EXTEND BOTH BARS DOWNWARD 24� PAST OPENING AND WITHIN 3� TO THE TOP OF THE
FOUNDATION WALL� USE �1� HORIZONTAL BAR WITHIN 2� OF BOTTOM OF OPENING� EXTEND 24� PAST
BOTH SIDES OF OPENING�
3� PLACE 12� [ 12� ANCHOR BOLTS # 32� O�C� W� A MIN� �� EMBEDMENT - U�N�O� USE 3� [ 3� [ 14� PLATE
WASHERS�
MARK
MASONRY WALL SCHEDULE
WIDTH HEIGHT
9' 4"
VERTICAL HORIZONTAL
#4 BARS @ 40" O.C.
NOTES:
1� ALL HORIZONTAL CORNER LAP SPLICES TO BE A MINIMUM OF 24� FROM FOUNDATION WALL CORNER 2� REBAR AROUND OPENINGS - USE �1� �� BAR WITHIN 2� OF BOTH SIDES OF OPENING� EXTEND BOTH BARS DOWNWARD 24� PAST
OPENING AND WITHIN 3� TO THE TOP OF THE FOUNDATION WALL� USE �1� HORIZONTAL BAR WITHIN 4� OF BOTTOM OF OPENING�
EXTEND 24� PAST BOTH SIDES OF OPENING�
3� PLACE �� � [ 12� ANCHOR BOLTS # 32� O�C� W� A MIN� �� EMBEDMENT - U�N�O� USE 3� [ 3� [ 14� PLATE WASHERS�
4� NORMAL WEIGHT CMU BLOC.S U�N�O
MW-1 8" #4 BARS @ 48" O.C.
NOTES
FULLY GROUTED WALL
MARK
MASONRY LINTEL SCHEDULE
REINFORCEMENTWIDTHDEPTHLEN.
ML-1 (1) #4 BAR CONT. 4" FROM BOTTOM OF LINTEL8" 24"3' - 7'
A-1
SHEET
STAMP
PROJECT NO:
DATE:
SCALE:
DRAWN BY:
CHECKED BY:
26-007
2.23.26
CKC
CKC
D A
TE
RE
V
IS
IO
N
PR
O
V O
B A
TH
RO
O M
S
- Q
UA
IL
O
RC
HA
RD
B
A
TH
PL
A
N S
1/4" = 1'-0" (24"x36")
8X8X16 SPLIT FACE
COLORED CONC. BLOCK
TYP.
METAL ROOFING
PROVIDE ALTERNATE
BID FOR ASPHALT
SHINGLES
METAL ROOFING
PROVIDE ALTERNATE
BID FOR ASPHALT
SHINGLES
ELEVATION 1
SCALE: 1/4"=1'-0"
ELEVATION 2
SCALE: 1/4"=1'-0"
ELEVATION 3
SCALE: 1/4"=1'-0"
E4 ELEVATION 4
SCALE: 1/4"=1'-0"
E1 E2 E3
8X8X16 SPLIT FACE
COLORED CONC. BLOCK
TYP.
'-9
11 16
BLOWN IN OR BATT R=38 INSULATION
ROOF TRUSSES PER STRUCTURAL
METAL RIBBED ROOFING OVER 30# FELT OVER
5/8" CDX PLYWOOD W/ 10d NAILS @ 6" O.C
FOOTING AND FOUNDATION PER STRUCTURAL
4" CONC. SLAB OVER 4" GRAVEL BASE MIN.
SLOPE TO DRAIN.
FULLY GROUT ALL CMU WALLS
8" GYP. BD. OVER 7/16" OSB OR 1/2" CDX
PLYWOOD
3/8" PREMOLDED JOINT TYP.
2X8 REDWOOD PLATE W/
5/8"ØX10" A.B. @24" O.C.
9' -4
9' -5
1 2"
SECTION
SCALE: 1/2"=1'-0"
2'
A-2
SHEET
STAMP
PROJECT NO:
DATE:
SCALE:
DRAWN BY:
CHECKED BY:
26-007
2.23.26
CKC
CKC
D A
TE
RE
V
IS
IO
N
PR
O
V O
B A
TH
RO
O M
S
- Q
UA
IL
O
RC
HA
RD
B
A
TH
EL
EV
A
TIO
N S
S
EC
TIO
N S
A-3
SHEET
STAMP
PROJECT NO:
DATE:
SCALE:
DRAWN BY:
CHECKED BY:
26-007
2.23.26
CKC
CKC
D A
TE
RE
V
IS
IO
N
PR
O
V O
B A
TH
RO
O M
S
- Q
UA
IL
O
RC
HA
RD
B
A
TH
D
ET
A
IL
S
1/4" = 1'-0" (24"x36")
13 1/2"
45" MIN.
27" CLEAR 3" CLEAR
" M
IN
42" GRAB BAR
48" GRAB BAR
COAT HOOK
@ 47" A.F.F
HANDLES
BOTH SIDES
12"
MIN.
12"-18" MIN.
18" MIN.
45" MIN.
" M
IN
CLEAR FLOOR SPACE
36" MIN.
" M
IN
13" MIN.
19" MAX.
CLEAR FLOOR
SPACE
/2
/2
RECESSED WASTE
RECEPTACEL
SANITARY NAPKIN/
TAMPON VENDER
HORIZONTAL MOUNT
BABY STATION
VERTICAL MOUNT
BABY STATION
/2
24"
16"-18"
12" MIN.
45" MIN. Clr.
30"
RECESSED SEAT
COVER DISP.
ALT. LOCATION
75"-79" CLR
28"
31 1/2" MIN.
40 1/2" MIN.
9" MAX.
39"-41"
" M
IN
7"-9"
RECESSED SEAT
COVER DISP.
SAN. NAP.
DISPOSAL IN
WOMEN'S ONLY
CENTER MIRROR
ON LAV.
SOAP DISP.
4"
6"
" M
IN
" M
AX
" M
AX
15" MIN. CLR.15" MIN. CLR.
" M
AX
11"
17"
" M
IN
PAPER TOWEL
DISP.
HAND DRYER
TO HIGHEST
OPERABLE PART 17
" M
AX
15" 15"
30" MIN. 13 12" MIN.
MIN. CLEAR
FLOOR SPACE
30"
URINAL PLANURINAL SIDEURINAL FRONT
ANY WALKING SURFACE
WITH A SLOPE GREATER
THAN 5% IS A RAMP AND
SHALL COMPLY WITH
GUIDLINES FOR RAMPS
FLOOR SURFACES SHALL BE
STABLE, FIRM AND SLIP
RESISTANT
NOTE:
2" OR GREATER RISE IN
ELEVATION SEE ADA RAMP
SLOPE DETAIL
MAXIMUM SLOPE WITH
HANDRAILS
MAXIMUM CROSS SLO
PE
OF R
AMPS
MAXIMUM SLOPE
WITHOUT HANDRAILS
20 48
1 4" M
AX
CLEAR FLOOR
SPACE
36" MIN.
56" MIN W. WALL MNTED W.C
" M
IN
59" MIN W. FLR. MNTED W.C
TYPICAL ADA DETAIL1 FLOOR SPACE @ WATER CLOSET2 FLOOR SPACE @ LAVS & SINKS3 STANDARD STALL (END OF ROW)4 MOUNTING HEIGHT OF MISC. FIXTURES5
CLEARANCES IN THE BATHROOM6
4 1/2" MAX.
6"
MIN.
7" M
IN
/2 " M
IN
" M
AX
17"-14 1/2"
5" MAX. 11 1/2" MIN.
EQUIPMENT PERMITTED
IN SHADED AREA
ONLY AND ALL PIPES
TO BE INSULATED
SPOUT HEIGHT AND
KNEE CLEARNACE
SPOUT HEIGHT AND KNEE CLEARANCE7 CLEARANCES FOR URINALS8
SCALE: 1/2"=1'-0" SCALE: 1/2"=1'-0" SCALE: 1/2"=1'-0" SCALE: 1/2"=1'-0" SCALE: 1/2"=1'-0"
SCALE: 1/2"=1'-0" SCALE: 1/2"=1'-0" SCALE: 1/2"=1'-0"
ADA SURFACE REQUIREMENTS9
SCALE: 1/2"=1'-0"
METAL FASCIA
FACTORY PAINTED
METAL DRIP EDGE
2X4 OUTLOOKER @
24" O.C. WITH INFILL
BLOCKING
7/16" OSB
METAL SOFFIT
5/8" Ø X 10" A.B @ 24" O.C.
8" BOND BEAM
W/ (2) #5
FULLY GROUT
ALL CMU WALLS
ROOF TRUSS
FULL DEPTH BLOCKING ANCHORED
TO TOP PLATE W/
SIMPSON A35@24" O.C.
BOUNDARY
NAILING
(7) 16D NAILS @
EACH OUTLOOKER
5/8" SHEATHING W/
10D @ 6" O.C. @
PANEL EDGE & 12"
O.C. FIELD
L3X3X3/16" X 0'-8" LONG
@ 48" O.C. W/ (3)
1/4"X1-1/2" SIMPSON
SDS SCREWS
7/16" OSB ATTACHED TO
BOTTOM OF PRE-FAB TRUSS
INFILL BLOCKING
METAL SOFFIT
METAL FASCIA
FACTORY PAINTED
METAL DRIP EDGE
2X4 BLOCKING RETURN
EVERY 3RD BLOCK FLATWISE
FOR VENTILATION
STANDING SEAM
METAL ROOFING
BOUNDARY NAILING
5/8" SHEATHING W/ 10D @
6" O.C. @ PANEL EDGE &
12" O.C. FIELD
ROOF TRUSS
16D @ 6" O.C
5/8" Ø X 10" A.B @ 24" O.C.
8" BOND BEAM
W/ (2) #5
METAL DOOR
JAMB
4" HOLLOW METAL
DOOR HEADER
CAULKING
(2) #5 BARS HORZ.
GROUT BOND
BEAM SOLID.
FULLY GROUT ALL
CMU WALLS
CONCRETE BLOCK CAULKING
2" HOLLOW METAL
DOOR JAMB
HOLLOW METAL
INSULATED DOOR
(2) #5 BAR
RAKE DETAIL10
SCALE: 1-1/2"=1'-0"
EAVE SOFFIT DETAIL11
SCALE: 1-1/2"=1'-0"
DOOR HEADER & JAMB DETAIL12
SCALE: 1-1/2"=1'-0"
2. SOILS REPORT:
A. IF SOILS CONDITIONS VARY FROM THE SOILS REPORT, THE CONTRACTOR SHALL IMMEDIATELY INFORM THE
ARCHITECT AND THE STRUCTURAL ENGINEER.
3. REQUIREMENTS:
A. DO NOT PLACE FOOTINGS OR FOUNDATIONS ON DISTURBED SOILS, UNDOCUMENTED FILL, DEBRIS, FROZEN
SOIL, OR IN PONDED WATER.
B. ALL UNSUITABLE SOILS AND VEGETATION, SUCH AS TOPSOIL, ORGANIC SOILS, UNDOCUMENTED FILL, DISTURBED NATIVE SOILS, AND OTHER DELETERIOUS MATERIALS, SHALL BE REMOVED FROM BELOW
FOOTINGS, FOUNDATIONS, AND FLOOR SLABS.
C. STRUCTURAL FILL SHALL CONSIST OF IMPORTED, WELL GRADED, GRANULAR SOIL WITH A MAXIMUM
PARTICLE SIZE OF THREE INCHES, LESS THAN 30 PERCENT RETAINED ON THE 3
4" SIEVE, AND LESS THAN 15
PERCENT FINES (MATERIAL PASSIN G THE NO. 200 SIEVE). THE LIQUID LIMIT OF THE FINES SHALL NOT EXCEED
35 PERCENT AND THE PLASTICITY INDEX SHALL BE BELOW 15.
D. STRUCTURAL FILL SHALL BE PLACED IN MAXIMUM EIGHT INCH LOOSE LIFTS AND COMPACTED ON A HORIZONTAL PLANE. MOISTURE SHALL BE MAINTAINED BY PROPER MIXING AT A MOISTURE CONTENT WITHIN TWO PERCENT OF THE OPTIMUM MOISTURE DETERMINED BY ASTM D 1557. COMPACT TO AT LEAST 95 PERCENT OF MAXIMUM DENSITY AS DETERMINED BY ASTM D 1557 BELOW FOOTINGS, FOUNDATIONS, AND FLOOR SLABS.
E. ALL STRUCTURAL FILL THAT BECOMES DISTURBED DURING CONSTRUCTION SHALL BE RE-COMPACTED PER
THE COMPACTION REQUIREMENTS SPECIFIED ABOVE. IF SOFT OR PUMPING CONDITIONS ARE
ENCOUNTERED, THE SUB-GRADE MUST BE PROPERLY STABILIZED. DE-WATERING, PLACEMENT OF
GEO-FABRIC, OR OTHER STABILIZATION MAY BE REQUIRED.
F. ALL SLABS ON GRADE SHALL BE UNDERLAIN BY FOUR INCHES OF FREE-DRAINING GRANULAR MATERIAL SUCH
AS "PEA" GRAVEL OR THREE-QUARTERS TO ONE INCH MINUS CLEAN GRAVEL.
4. CONSTRUCTION:
A. CONCRETE SHALL BE PROPERLY VIBRATED DURING PLACEMENT.
B. PRIOR TO PLACING CONCRETE, CHECK WITH ALL TRADES TO ENSURE PROPER PLACEMENT OF OPENINGS, BLOCK
OUTS, SLEEVES, CURBS, CONDUITS, BOLTS, INSERTS, EMBEDS, DOWELS, ETC. ANCHOR BOLTS AND DOWELS
SHALL BE PLACED PRIOR TO CASTING CONCRETE.
C. CONSTRUCTION JOINTS AND BULKHEADS SHALL BE FORMED WITH A KEYWAY. ALL CONTACT SURFACES, NEW OR EXISTING, AT CONSTRUCTION JOINTS SHALL BE INTENTIONALLY ROUGHENED PRIOR TO CASTING
ADJACENT POUR.
D. OPENINGS IN FLOORS AND/OR WALLS SHALL HAVE ADDITIONAL REINFORCING AROUND ALL SIDES OF THE OPENING EQUIVALENT TO THE BARS CUT BY THE OPENING WITH HALF ON EACH SIDE OF THE OPENING OR 2-#4 BARS, WHICHEVER IS GREATER, UNLESS NOTED OTHERWISE. BARS PARALLEL TO THE PRINCIPAL REINFORCING SHALL RUN FULL LENGTH OF THE SPAN. BARS IN THE OTHER DIRECTION SHALL RUN 24 INCHES BEYOND THE EDGE OF THE OPENING OR END WITH A STANDARD HOOK. ALSO PROVIDE 2-#4 x 4'-0" DIAGONAL
BARS AT EACH CORNER OF EACH OPENING.
E. NO PENETRATION SHALL BE ALLOWED THROUGH ANY CONCRETE BEAM, JOIST, COLUMN, PIER, WALL, OR JAMB WITHOUT THE ARCHITECT'S AND STRUCTURAL ENGINEER'S PRIOR WRITTEN APPROVAL. PENETRATIONS SHALL
BE RE-ROUTED AS REQUIRED AT THESE LOCATIONS.
5. FOOTINGS:
C. EXTERIOR FOOTINGS SHALL BEAR BELOW THE EFFECTS OF FROST.
D. STAGGER FOOTING CONSTRUCTION JOINTS FROM WALL CONSTRUCTION JOINTS ABOVE BY AT LEAST 6 FEET.
E. REINFORCING IN CONTINUOUS FOOTINGS SHALL BE CONTINUOUS AT CORNERS AND/OR INTERSECTIONS BY
PROVIDING PROPER LAP LENGTHS AND/OR CORNER BARS.
F. EXTERIOR CONTINUOUS FOOTINGS WITHOUT CONCRETE FOUNDATION WALLS ABOVE SHALL BE REINFORCED WITH A MINIMUM OF 2-#4 LONGITUDINAL TOP BARS IN ADDITION TO REINFORCING SPECIFIED IN THE FOOTING
SCHEDULE.
G. NO PENETRATIONS SHALL BE ALLOWED THROUGH ANY CONCRETE FOOTING. WHEN CONFLICTS ARISE BETWEEN UNDERGROUND PLUMBING, UTILITIES, ETC., THE FOOTING SHALL BE STEPPED DOWN BELOW THE CONFLICT AND A CONCRETE WALL, PIER, COLUMN, ETC., SHALL BE EXTENDED TO THE FOOTING AS REQUIRED.
H. BEARING SURFACES FOR FOOTINGS WHICH ARE, OR BECOME, UNDERMINED DURING CONSTRUCTION SHALL
BE BACKFILLED WITH A LEAN-MIX CONCRETE (1000 PSI MIN.).
6. SLABS ON GRADE:
A. INTERIOR SLABS ON GRADE SHALL BE A MINIMUM OF 4 INCHES THICK, SHALL BEAR ON A 4 INCH MINIMUM
LAYER OF FREE-DRAINING GRAVEL.
7. WALLS:
A. PLACE VERTICAL REINFORCING IN THE CENTER OF THE WALL (EXCEPT FOR RETAINING WALLS, OR WHEN EACH
FACE IS SPECIFIED).
B. VERTICAL REINFORCING SHALL BE DOWELED TO FOOTING OR STRUCTURE BELOW AND TO STRUCTURE ABOVE
WITH THE SAME SIZE BAR AND SPACING, TYPICAL, UNLESS NOTED OTHERWISE.
C. PROVIDE CORNER BARS AT ALL INTERSECTIONS AND CORNERS. USE SAME SIZE BAR AND SPACING AS THE
HORIZONTAL REINFORCING.
D. HORIZONTAL REINFORCING SHALL TERMINATE AT THE ENDS OF WALLS AND AT OPENINGS WITH A STANDARD
HOOK.
E. WHEN TWO CURTAINS OF STEEL ARE REQUIRED, THE SPLICES IN THE HORIZONTAL REINFORCING OF EACH
CURTAIN SHALL NOT OCCUR AT THE SAME LOCATION.
F. PROVIDE DRAINAGE AT THE BASE OF RETAINING WALLS AND AT THE BASE OF ALL BASEMENT WALLS.
1. CODES AND STANDARDS:
A. REINFORCING STEEL SHALL COMPLY WITH:
I. CONCRETE REINFORCING STEEL INSTITUTE "MANUAL OF STANDARD PRACTICE".
II. AMERICAN CONCRETE INSTITUTE "DETAILING MANUAL", ACI 315 (OR SP-66).
2. MATERIALS:
A. REINFORCING STEEL SHALL BE NEW STOCK DEFORMED BARS AND SHALL CONFORM TO ASTM A615, GRADE 60, WITH A DESIGN YIELD STRENGTH OF 60,000 PSI, EXCEPT AS NOTED BELOW.
I. DOWELS TO BE BENT IN THE FIELD DURING CONSTRUCTION SHALL BE ASTM A615, GRADE 40 OR ASTM
A706, GRADE 60, "LOW ALLOY STEEL".
II. REINFORCING TO BE WELDED SHALL BE ASTM A706, GRADE 60, "LOW-ALLOY STEEL".
3. CONSTRUCTION:
A. REINFORCING SHALL BE DETAILED, BOLSTERED, AND SUPPORTED PER ACI 318 AND IBC.
B. REINFORCING STEEL SHALL BE FREE OF LOOSE, FLAKY RUST, SCALE, GREASE, OIL, DIRT, AND OTHER
MATERIALS WHICH MIGHT AFFECT OR IMPAIR BOND.
C. REINFORCING SHALL BE CONTINUOUS IN WALLS, BEAMS, COLUMNS, SLABS, FOOTINGS, ETC.
D. SPLICES IN CONTINUOUS REINFORCING SHALL BE MADE IN AREAS OF COMPRESSION AND/OR AT POINTS OF
MINIMUM STRESS, TYPICAL UNLESS NOTED OTHERWISE. LAP SPLICES SHALL BE 40 BAR DIAMETERS LONG IN CONCRETE AND 48 BAR DIAMETERS LONG IN MASONRY. MINIMUM LAP SHALL BE 24 INCHES LONG. DOWELS SHALL HAVE A MINIMUM OF 30 BAR DIAMETERS EMBEDMENT. TENSION SPLICES SHALL BE USED IN CONCRETE WHEN SPECIFICALLY NOTED, USE A CLASS B SPLICE. SPLICES IN TOP BARS IN SUSPENDED SLABS AND BEAMS SHALL BE MADE AT MID SPAN. SPLICES IN BOTTOM BARS IN SUSPENDED SLABS AND BEAMS SHALL BE
MADE AT SUPPORTS.
E. BENDS SHALL BE MADE COLD. DO NOT USE HEAT. BENDS SHALL BE DONE IN THE FABRICATOR'S SHOP UNLESS SPECIFICALLY NOTED FOR THE FIELD. DO NOT UN-BEND OR RE- BEND A PREVIOUSLY BENT BAR.
F. REINFORCING STEEL IN CONCRETE SHALL BE SECURELY ANCHORED AND TIED IN PLACE PRIOR TO PLACING
CONCRETE AND SHALL BE POSITIONED WITH THE FOLLOWING MINIMUM CONCRETE COVER:
CONCRETE EXPOSED TO EARTH OR WEATHER:
CONCRETE NOT EXPOSED TO EARTH OR WEATHER:
CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH.......3"
#6 AND LARGER...................................................................................2" #5 AND SMALLER.................................................................................1 1/2"
SLABS AND WALLS, #11 AND SMALLER............................................1 1/2"
BEAMS AND COLUMNS, MAIN REINFORCING OR TIES...................1 1/2"
SLABS ON GRADE................................................................................CENTER OF SLAB
G. NO REINFORCING STEEL SHALL BE WELDED UNLESS SPECIFICALLY NOTED AS SUCH. USE E90XX ELECTRODES
AND ASTM A706 REINFORCING. COMPLY WITH AWS REQUIREMENTS.
A. FOOTINGS SHALL BEAR ON PROPERLY PREPARED MATERIAL. SEE THE SITE PREPARATION NOTES.
B. FOOTINGS SHALL BE CENTERED BELOW THE WALL AND/OR COLUMN ABOVE, TYPICAL UNLESS NOTED
OTHERWISE.
REINFORCING STEEL
SITE PREPARATION
CONCRETE
1. STRUCTURAL ENGINEER ASSUMES NO LIABILITY FOR THE ACCURACY, COMPLETENESS, OR CODE COMPLIANCE OF
ARCHITECTURAL, ELECTRICAL, MECHANICAL OR DRAINAGE SPECS.
B. FDN DESIGN BASED ON THE NOTED PSF SOIL BEARING CAPACITY. WE RECOMMEND THAT A LICENSED
GEOTECHNICAL ENGINEER VERIFY THE SOIL BEARING CAPACITY, SLOPE STABILITY, ETC.
G. ANCHOR BOLTS ARE TO HAVE A MIN. 7" EMBEDMENT INTO CONCRETE. PROVIDE 1 BOLT A MIN. OF 4" FROM END OF PLATE & A MAX. OF 12" FROM END OF PLATE. EACH PLATE IS TO HAVE A MIN. OF 2 BOLTS. ANCHOR BOLT
SPACING IS NOT TO EXCEED 32" O.C. U.N.O. ON PLANS.
G. THE GROUND IMMEDIATELY ADJACENT TO THE FOUNDATION SHALL HAVE A 5-PERCENT SLOPE AWAY FROM THE BUILDING FOR A MINIMUM DISTANCE OF 10 FEET MEASURED PERPENDICULAR TO THE FACE OF THE FOUNDATION WALL. IF PHYSICAL OBSTRUCTIONS OR LOT LINES PROHIBIT 10 FEET OF HORIZONTAL DISTANCE, A 5-PERCENT SLOPE SHALL BE PROVIDED TO AN APPROVED ALTERNATIVE METHOD OF DIVERTING WATER AWAY FROM THE FOUNDATION. IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING FOUNDATION SHALL
HAVE A MINIMUM 2-PERCENT SLOPE.
1. CONCRETE MATERIALS, QUALITY CONTROL, AND CONSTRUCTION SHALL COMPLY WITH CURRENT EDITIONS OF IBC
AND ACI 318.
2. COMPRESSIVE STRENGTH (MINIMUM SPECIFIED AT 28 DAYS)
A. FOOTINGS: 3,000 PSI
B. INTERIOR FLOOR SLABS ON GRADE: 4,000 PSI
C. EXTERIOR FLOOR SLABS ON GRADE: 4,000 PSI
D. SUSPENDED SLABS: 4,000 PSI
E. WALLS: 3,000 PSI FOR R-2 AND R-3 OCCUPANCIES, 4,000 PSI
FOR OTHER
3. MATERIALS
A. CEMENTS (ASTM C 150). CONCRETE EXPOSED TO FREEZING AND THAWING OR DEICING CHEMICALS SHALL
CONFORM TO THE MAXIMUM WATER-CEMENTITIOUS MATERIAL RATIOS AND MINIMUM COMPRESSIVE
STRENGTH REQUIREMENTS OF ACI-318.
B. AGGREGATES (ASTM C 33): NOMINAL MAXIMUM SIZE OF COARSE AGGREGATE SHALL NOT BE LARGER THAN 15 THE NARROWEST DIMENSION BETWEEN FORMS, NOR 13 THE DEPTH OF SLABS, NOR 34 THE MINIMUM CLEAR
SPACING BETWEEN REINFORCING BARS OR WIRES, TENDONS, OR DUCTS.
C. WATER USED IN MIXING CONCRETE SHALL BE POTABLE, CLEAN AND FREE FROM INJURIOUS AMOUNTS OF OILS, ACIDS, ALKALIS, SALTS, ORGANIC MATERIALS, OR OTHER SUBSTANCES DELETERIOUS TO CONCRETE OR
REINFORCEMENT.
D. ADMIXTURES SHALL BE SUBJECT TO PRIOR APPROVAL BY THE REGISTERED DESIGN PROFESSIONAL IN
RESPONSIBLE CHARGE.
E. CONCRETE EXPOSED TO FREEZING AND THAWING OR DEICING CHEMICALS SHALL BE AIR-ENTRAINED WITH AIR CONTENT INDICATED IN ACI 318. TOLERANCE ON AIR CONTENT AS DELIVERED SHALL BE PLUS/MINUS 1.5
PERCENT.
POST INSTALLED ANCHORS
1. EPOXY ADHESIVE ANCHORING SYSTEMS:
A. CONCRETE: HILTI HIT-RE 500-SD OR SIMPSON SET-XP.
B. MASONRY (GROUTED): HILTI HIT-HY 150-MAX OR SIMPSON SET.
C. STEEL REINFORCEMENT AND RODS SHALL BE EMBEDDED 10 BAR DIAMETERS UNLESS NOTED OTHERWISE IN
THE STRUCTURAL DRAWING AND DETAILS. WHERE 10 BAR DIAMETERS EXCEED THE MEMBER THICKNESS MINUS MINIMUM COVER, STEEL REINFORCEMENT SHALL BE EMBEDDED THE MEMBER THICKNESS MINUS
MINIMUM COVER WITH A STANDARD HOOK.
D. EMBEDDED PORTIONS OF STEEL REINFORCEMENT AND RODS SHALL BE CLEAN, STRAIGHT, AND FREE OF MILL SCALE, RUST AND OTHER COATINGS THAT IMPAIR THE BOND WITH THE ADHESIVE. REINFORCEMENT
MUST NOT BE BENT AFTER INSTALLATION.
2. MECHANICAL EXPANSION ANCHORS:
A. CONCRETE: HILTI KWIK BOLT TZ.
B. MASONRY: HILTI KWIK BOLT 3.
C. EXPANSION ANCHORS SHALL NOT BE USED IN TENSILE LOAD APPLICATIONS (E.G. HOLDOWNS, MOMENT
FRAMES) AND MAY NOT BE USED TO SUBSTITUTE OTHER ANCHOR SYSTEMS.
3. POST-INSTALLED ANCHORING SYSTEMS SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS. HOLE CLEANING METHOD SHALL BE BASED ON DRILLING METHOD AND BORE HOLE
CONDITIONS AND SHALL CONFORM TO THE MANUFACTURER'S INSTRUCTIONS.
2. THE GENERAL CONTRACTOR SHALL:
A. FIELD VERIFY ALL SITE CONDITIONS AND IMMEDIATELY NOTIFY THE ARCHITECT AND STRUCTURAL
ENGINEER REGARDING ANY DISCREPANCIES WITH ACTUAL CONDITIONS AT THE SITE.
B. COORDINATE ALL WORK BETWEEN THE VARIOUS TRADES AND SUBCONTRACTORS. REPORT ANY
MODIFICATIONS TO THE STRUCTURAL PORTION OF THE BUILDING BY OTHER TRADES TO THE ARCHITECT AND
ENGINEER.
3. CONTRACT DOCUMENTS:
A. DETAILS, SECTIONS AND NOTES SHOWN ON THE STRUCTURAL DRAWINGS ARE INTENDED TO BE TYPICAL AND
SHALL APPLY TO ALL SIMILAR SITUATIONS ELSEWHERE, UNLESS NOTED OR SHOWN OTHERWISE.
B. THE CONTRACT DOCUMENTS SHALL TAKE PRECEDENCE OVER SHOP DRAWINGS UNLESS SPECIFICALLY NOTED
OTHERWISE.
4. BUILDING CODE COMPLIANCE:
A. INSPECTION, TESTING, CONSTRUCTION, WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE
REQUIREMENTS OF THE GOVERNING BUILDING CODE AND STANDARDS. ASTM AND IBC DESIGNATIONS SHALL
BE AMENDED TO LATEST DATE UNLESS NOTED OTHERWISE.
5. CONSTRUCTION SEQUENCE, SHORING, AND BRACING REQUIREMENTS:
A. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE METHOD, MEANS, AND SEQUENCE OF ALL STRUCTURAL
ERECTION EXCEPT WHEN SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. HE SHALL PROVIDE TEMPORARY SHORING AND BRACING AS HIS METHOD OF ERECTION REQUIRES TO PROVIDE ADEQUATE VERTICAL AND LATERAL SUPPORT DURING ERECTION. THIS SHORING AND BRACING SHALL REMAIN IN PLACE UNTIL ALL PERMANENT MEMBERS ARE PLACED AND ALL FINAL CONNECTIONS ARE COMPLETED, INCLUDING ALL
ROOF AND FLOOR ATTACHMENTS.
B. SHORING AND SUPPORTING FORM WORK FOR SUSPENDED CONCRETE OR MASONRY MATERIAL SHALL REMAIN IN PLACE AND SHALL NOT BE REMOVED UNTIL THE STRUCTURAL MEMBERS HAVE ACQUIRED SUFFICIENT STRENGTH TO SAFELY SUPPORT THEIR OWN WEIGHT AND ANY ADDITIONAL CONSTRUCTION, STORAGE, AND/OR OTHER LOADS TO WHICH THEY MAY BE SUBJECTED. IN NO CASE SHALL THEY BE REMOVED PRIOR TO 7 DAYS. RE-SHORING SHALL BE IMMEDIATELY INSTALLED UPON REMOVAL OF SUCH FORMS AND SHALL REMAIN IN PLACE UNTIL 28 DAYS AFTER PLACING OF MATERIAL OR UNTIL MATERIAL HAS REACHED ITS 28 DAY DESIGN STRENGTH, WHICHEVER IS LONGER. DO NOT REMOVE LARGE AREAS OF
SHORING BEFORE STARTING RE-SHORING PROCEDURES.
C. NON-BEARING INTERIOR WALLS SHALL BE ADEQUATELY BRACED TO THE STRUCTURE ABOVE WITH
ALLOWANCE FOR DEFLECTION OF THE STRUCTURE ABOVE AND/OR BELOW.
D. BUILDING WALLS WHICH RETAIN EARTH MUST BE BRACED AT THE TOP. DO NOT BACKFILL UNLESS BRACING IS PROVIDED OR UNTIL THE COMPLETE FLOOR OR ROOF SYSTEM IS IN PLACE, TYPICAL, UNLESS NOTED
OTHERWISE.
6. OMISSIONS AND/OR CONFLICTS:
A. OMISSIONS IN AND/OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE CONTRACT DOCUMENTS SHALL
BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT AND STRUCTURAL ENGINEER AND SHALL BE
RESOLVED BY THE SAME BEFORE PROCEEDING WITH ANY WORK INVOLVED.
1. ALL JOISTS, RAFTERS, POSTS AND HEADERS SHALL BE DOUGLAS FIR LARCH NO.2 OR EQUAL U.N.O.
3. ALL WOOD/LUMBER PLACED ONTO CONCRETE SHALL BE PRESSURE TREATED OR REDWOOD.
4. ALL WOOD CONNECTIONS MUST CARRY THE CAPACITY OF THE MEMBER, CONTRACTOR IS RESPONSIBLE FOR
CONNECTIONS. IF OTHER THAN STANDARD CONNECTIONS ARE REQUIRED, SEE PROJECT ENGINEER FOR ADDITIONAL
ASSISTANCE. USE SIMPSON OR EQUAL CONNECTIONS FOR WOOD TO WOOD.
5. ALL COLUMNS SHALL EXTEND DOWN THROUGH THE STRUCTURE TO THE FOUNDATION. ALL COLUMNS SHALL BE BRACED AT ALL FLOOR LEVELS. COLUMNS SHALL BE AS WIDE AS THE MEMBER THEY SUPPORT. POSTS
SUPPORTED BY SLABS OR FND WALLS TO HAVE SIMPSON CB POST BASE OR EQUIVALENT.
8. ALL BEAMS AND HEADERS OVER 48" SHALL BE SUPPORTED BY DOUBLE TRIMMERS UNLESS NOTED OTHERWISE.
9. TRUSS MANUFACTURER SHALL PROVIDE ENGINEERING SPECS. FOR ALL TRUSSES.
8d NAILS @ 6" O.C. AT EDGES OF ROOF 8d NAILS @ 4" O.C. AT GABLE ENDS
SPACE NAILS 12" O.C. ON INTERMEDIATE MEMBERS
STAGGER SHEATHING JOINTS
SHEATHING PERP. TO RAFTERS AND TRUSSES
11. PROVIDE SQUASH BLOCKING AT RIM JOIST BELOW ALL POSTS FROM ROOF, HEADER OR BEAM POINT LOADS. SQUASH
BLOCKING TO BE SAME MATERIAL AS POST ABOVE.
13. GLULAM BEAMS SHALL BE 24F-V4 DF/DF FOR SINGLE SPANS AND 24F-V8 DF/DF FOR MULTIPLE SPANS, AND CANTILEVERED SPANS. GLULAMS EXPOSED TO WEATHER SHALL BE PRESSURE TREATED OR PROVIDE WEATHER
PROTECTIVE COATING.
15. ALL RAFTERS AND JOISTS OVER THREE FEET LONG SHALL BE HANGERED IF NOT SUPPORTED BY BOTTOM BEARING. ALL HANGERS AND OTHER WOOD CONNECTIONS MUST BE DESIGNED TO CARRY THE CAPACITY OF THE
MEMBER THAT THEY ARE SUPPORTING.
16. FRAMING CONNECTIONS NOTED ON THE DRAWINGS ARE SIMPSON STRONG-TIE OR EQUAL. INSTALL WITH THE
CATALOG DESIGNATED CONNECTOR IN EACH HOLE.
17. NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS SPECIFICALLY SHOWN, NOTED OR APPROVED BY
ENGINEER.
18. LAG SCREWS SHALL BE INSERTED IN A DRILLED PILOT HOLE 60%-75% OF THE SHANK DIAMETER BY TURNING WITH A WRENCH, NOT BY DRIVING WITH A HAMMER. ALL NUTS, BOLTS AND LAG SCREWS SHALL BE PROVIDED WITH AN
OVERSIZED WASHER.
20. ALL BOLT HOLES SHALL BE DRILLED WITH A BIT 1
32" TO 1
16" LARGER THAN THE NOMINAL BOLT DIAMETER.
21. ALL JOINTS IN WALL SHEATHING SHALL OCCUR IN THE MIDDLE OF A PLATE OR BLOCK AND NAILED ON EACH SIDE
OF THE JOINT WITH EDGE NAILING PER SHEARWALL SCHEDULE.
22. COLUMNS AND POSTS LOCATED ON CONCRETE OR MASONRY FLOORS OR DECKS EXPOSED TO THE WEATHER OR
TO WATER SPLASH OR IN BASEMENTS, AND WHICH SUPPORT PERMANENT STRUCTURES, SHALL BE SUPPORTED BY CONCRETE PIERS OR METAL PEDESTALS PROJECTING ABOVE FLOORS UNLESS APPROVED WOOD OF NATURAL RESISTANCE TO DECAY OR TREATED WOOD IS USED. THE PEDESTAL SHALL PROJECT AT LEAST 6" ABOVE
EXPOSED EARTH & AT LEAST 1" ABOVE SUCH FLOORS.
2. ALL JOISTS AND RAFTERS SHALL HAVE SOLID BLOCKING AT THEIR BEARING POINTS.
6. ALL FLOOR SHEATHING TO BE 3
4" THICK T&G SHEATHING GLUED AND NAILED WITH 8d COMMON NAILS OR EQUAL
@ 6" O.C. EDGES AND @ 12" O.C. IN THE FIELD.
12. PROVIDE DOUBLE FLOOR JOISTS BELOW ALL PARALLEL BEARING WALLS ABOVE.
GENERAL FRAMING NOTES
14. LAMINATED VENEER LUMBER (LVL) SHALL HAVE THE FOLLOWING PROPERTIES:E=2000KSI,Fb=2600PSI,Fv=285PSI.
10. 7 16" ROOF NAILING SCHEDULE AS FOLLOWS: (58" ROOF SHEATHING TO USE 10d NAILS)
7. VERIFY ALL BEAM SIZES WITH ENGINEERING SPECIFICATIONS.
19. NAILS TO BE COMMON WIRE UNLESS OTHERWISE NOTED.
23. ALL FASTENERS IN PRESSURE TREATED LUMBER ARE TO COMPLY WITH CURRENT IBC REQUIREMENTS.
25. CHIMNEY & FIREPLACE FRAMING - PROVIDE FULL HT. 2x6 STUDS (MIN.) FROM BEARING TO TOP OF CHIMNEY.
USE (2) 14"x31
2" SDS SCREWS AT EACH STUD TO RAFTER/TRUSS CHORD INTERSECTION.
26. PROVIDE (2) KING STUDS ON EACH SIDE OF HEADER GREATER THAN 8'-0" IN LENGTH U.N.O.
1. CONSTRUCTION DOCUMENTS ARE VALID FOR A SINGLE USE AT THE PROJECT LOCATION AND SHALL NOT BE REUSED, COPIED, OR REPRODUCED WITHOUT WRITTEN APPROVAL OF THE REGISTERED DESIGN PROFESSIONAL IN
RESPONSIBLE CHARGE.
24. ALL STAPLES INTO WOOD DIAPHRAGMS ARE TO BE A MINIMUM OF 11
2" 16 GAGE WITH SPACING PER PLANS.
DEFERRED SUBMITTAL NOTES
NOTE: 2500 PSI CONCRETE USED IN FOOTING DESIGN, HIGHER STRENGTHS SPECIFIED FOR QUALITY CONTROL.
H. ANCHOR BOLT WASHERS TO BE A MINIMUM 3"x3"x0.229" WITH ROUND OR SLOTTED HOLES WITH CUT WASHER
AND PLACED WITHIN 12" OF SHEATHED FACE OF PLATE.
1. PRE-FABRICATED METAL PLATE TRUSSES ARE TO BE SUBMITTED SUBSEQUENT TO THE TIME OF APPLICATION.
2. DEFERRED SUBMITTALS SHALL HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL.
3. DEFERRED SUBMITTAL DOCUMENTS SHALL BE SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
RESPONSIBLE CHARGE WHO SHALL REVIEW AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO THE
DESIGN OF THE BUILDING.
4. DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN
APPROVED BY THE BUILDING OFFICIAL.
D. LARGE AREAS OF INTERIOR SLABS ON GRADE SHALL BE PLACED IN STRIPS NOT TO EXCEED 120 FEET IN LENGTH NOR 30 FEET IN WIDTH WHICH ARE SUBDIVIDED BY CONSTRUCTION AND/OR CONTRACTION (CONTROL) JOINTS INTO ROUGHLY SQUARES WHOSE SIDES SHALL NOT EXCEED 15 FEET IN EITHER DIRECTION.
B. CONTROL JOINT SPACING RULE OF THUMB IS 24x_ SLAB THICKNESS (4" SLAB = 8'-0" MAX O.C. EACH WAY).
PROVIDE CONTROL JOINTS AT APPROX. 15'-0" EACH WAY (MAXIMUM).
C. SAW CUT WITHIN 6-18 HOURS OF POURING CONCRETE - 24 HOURS MAX. CONCRETE MUST BE HARD ENOUGH
TO PREVENT RAVELING OF JOINT EDGES OR DISLODGING OF COURSE AGGREGATE.
7. REMODEL AND ADDITION PLANS:
A. THE ENGINEER ASSUMES NO LIABILITY FOR THE DESIGN AND CONSTRUCTION OF THE EXISTING BUILDING.
B. NOTIFY ENGINEER OF ANY DISCREPANCIES WITH THE EXISTING SITE AND PROPOSED CONSTRUCTION
DOCUMENTS PRIOR TO TO ANY DEMOLITION AND CONSTRUCTION.
STRUCTURAL DESIGN CRITERIA
ROOF LOADING: FLOOR LOADING:
ROOF DEAD LOAD
ROOF LIVE LOAD
ROOF SNOW LOAD
15.0 PSF
20.0 PSF
49.1 PSF
64.0 PSF
49.1 PSF
1.0
VERTICAL LOADS
GROUND SNOW LOAD, Pg FLAT ROOF SNOW LOAD, Pf EXPOSURE FACTOR, Cs THERMAL FACTOR, Ct
IMPORTANCE FACTOR, I
DRIFT SURCHARGE
1.0 1.0
PER PLAN
FLOOR DEAD LOAD
FLOOR LIVE LOAD
15.0 PSF
40.0 PSF
WALL WEIGHT:
FLOOR DEAD LOAD (FRAMING) 70.0 PSF
GOVERNING CODE: IBC 2021
SOIL CRITERIA:
GEOTECH STUDY:
SOIL BEARING PRESSURE:
FROST DEPTH:
SOIL SITE CLASS:
NONE
1,500 PSF
30 INCHES
D
HORIZONTAL LOADS
WIND PARAMETERS: SEISMIC PARAMETERS:
SEISMIC RISK CATEGORY
SEISMIC DESIGN CATEGORY
SPECTRAL RESPONSE ACCELERATIONS
ULTIMATE DESIGN WIND SPEED
NOMINAL DESIGN WIND SPEED
WIND RISK CATEGORY
1.56g 0.57g 1.00g
Ss
S1
Fa
Fv
Sds
Sd1
1.80g 1.04g 0.68g
FORCE RESISTING SYSTEM MASONRY
3.5
R Cd Ω
IMPORTANCE FACTOR, I 1.0
DESIGN BASE SHEAR, V 0.127*W
ANALYSIS PROCEDURE E.L.F.
WIND EXPOSURE
INTERNAL PRESSURE COEFFICIENT
CLADDING PRESSURE
105MPH
85 MPH
II
C 0.18
16.0 PSF
SD-0
SHEET
STAMP
PROJECT NO:
DATE:
SCALE:
DRAWN BY:
CHECKED BY:
26-007
2.23.26
CKC
CKC
D A
TE
RE
V
IS
IO
N
PR
O
V O
B A
TH
RO
O M
S
- Q
UA
IL
O
RC
HA
RD
B
A
TH
ST
RU
C
TU
RA
L
N O
TE
S
NTS
TYP. CONCRETE CORNER REINFORCING
LAP SPLICE LAP SPLICE
CONTINUOUS BARS
PER PLANS
CORNER BAR - LAP SPLICE
20��MIN��
FOUNDATION WALLS
PER PLAN
CORNER
SINGLE MAT
CORNER
DOUBLE MAT
INTERSECTION
SINGLE MAT
INTERSECTION
DOUBLE MAT
CONTINUOUS BARS
PER PLANS
CORNER BAR - LAP SPLICE
20� �MIN��
FOUNDATION WALLS
PER PLAN
LAP SPLICE LAP SPLICE
�2� �4 BARS # 40� O�C� HORIZONTAL
�SEE PLANS�
CMU MASONR< WALL PER PLANS�
SEE MASONR< NOTES
CONCRETE SLAB� SEE CONCRETE NOTES
SOLID GROUT ALL CELLS BELOW GRADE
CONCRETE FOOTING SEE FOUNDATION PLAN
FINISH GRADE�
SLOPE AWA<
3" C
O
VE
R
M
IN
. F R
O
ST
D
EP
TH
�4 --BARS # 1�� O�C� �MIN LAP SPLICE 30��
- ��� --BARS # �� O�C� PER PLANS�
SOLID GROUT ALL REINFORCED CELLS
�4 BARS # 4�� O�C� VERTICAL
PLACE REBAR IN CENTER OF WALL
CMU FOUNDATION WALL DETAIL2
�2� �4 BARS # 40� O�C� HORIZONTAL
�SEE PLANS�
CMU MASONR< WALL PER PLANS�
SEE MASONR< NOTES
CONCRETE SLAB� SEE CONCRETE NOTES
FOUNDATION WALL PER PLAN
CONCRETE FOOTING SEE FOUNDATION PLAN
FINISH GRADE�
SLOPE AWA<
3"
CO
VE
R
M
IN
. F
RO
ST
D
EP
TH
SOLID GROUT ALL REINFORCED CELLS
�4 BARS # 4�� O�C� VERTICAL
PLACE REBAR IN CENTER OF WALL
CMU TO FOUNDATION WALL DETAIL3
VERTICAL WALL REINFORCEMENT
PROVIDE �2� �4 BAR
VERTICAL
IN ALL CORNER CELLS �OR
�� BARS PER PLANS�
LAP CORNER UNITS IN SUCCESSIVE
COURSES
PROVIDE CORNER LAP BARS
�MIN� LAP 30� EACH SIDE�
HORIZONTAL WALL REINFORCEMENT
2[4 BLOC.ING� TWO BA<S
WITH �4� �G NAILS PER BLOC.
PL<WOOD SHEATHING PER PLAN
BOUNDAR< NAILING PER PLAN
2[4 BRACE # 4�� O�C� W�
SIMPSON A3� AT BOTTOM END
PRE-FAB WOOD TRUSSES PER
PLAN
PL<WOOD SHEATHING PER PLAN
SIMPSON A3� # 4�� O�C� -
BRACE TO PLATE
BOUNDAR< NAILING PER PLAN
2[� DOUBLE TOP PLATE �BOTTOM
PLATE TO BE PRESSURE
TREATED�
CMU WALL PER PLANS
ROOF SHEATHING AS CALLED
OUT IN NAILING SCHEDULE
PRE-MANUFACTURED ROOF
TRUSSES AS SHOWN ON
FRAMING PLAN
10G NAILS # �� O�C� �DIAPHRAGM
BOUNDAR< NAILING� U�N�O�
2[ FULL HEIGHT BLOC.ING� HOLD
DOWN EVER< 4TH BLOC. FOR VENT�
H1 CLIP ON EACH TRUSS �24� O�C��
TO WALL CONNECTION U�N�O�
A3� CLIPS # 24� �1 PER BLOC.�
DOUBLE 2[� TOP PLATE �BOTTOM
PLATE TO BE PRESSURE TREATED�
CMU WALL PER PLANS
�� ANCHOR BOLT # 32� O�C�
�UNO�-EMBED A MIN� OF ��
�� ANCHOR BOLT # 32� O�C� �UNO�-
EMBED A MIN� OF ��
�2� 2[� TOP PLATE
�� ANCHOR BOLT PER PLANS
�2� �4 HOO.S # 24� O�C� �EXTEND
24� BE<OND EACH SIDE OF DOOR
OPENING�
�1� �4 BARS CONTINUOUS �OR �� BARS PER PLANS�
NOTES:
1� EXTEND LINTEL REINFORCEMENT A MIN�
OF 24� PAST OPENING�
�1� �4 BARS CONTINUOUS IN LINTEL
SOLID GROUT ALL CELLS OF LINTEL
�� CMU BLOC. �OR 10� PER PLANS�
4� CLEARANCE �T<P� TOP AND BOTTOM OF LINTEL�16
SE
E
PL
AN
S)
8"-10"
(SEE PLANS)
SAWCUT FACE OF MASONR< 1�
DEEP AT CONTROL -OINT
MASONR< PIER REINFORCEMENT PER PLANS
LINTEL REINFORCEMENT GROUT
CONTINUOUS THRU PIER
DO NOT PLACE END BLOC. AT
EDGE OF LINTEL
LINE OF �SAW CUT� CONTROL -OINT
CUT OUT ENDS OF
MASONR< FOR FULL
GROUT PENETRATION
ELEVATION VIEW
PLAN VIEW
CONTROL JOINT IN WALL
TYPICAL EXPANSION JOINT
HORIZONTAL REINFORCEMENT � BOND
BEAM CONTINUOUS THRU -OINT
�1� VERTICAL BAR EACH SIDE OF -OINT
SEE ARCHITECTURAL PLANS FOR CONTROL
-OINT AND SEALANT
SEE ARCHITECTURAL PLANS
FOR -OINT SIZE AND CLOSURE
MASONRY WALL CORNER DETAIL4 LINTEL DETAIL5
CMU EXPANSION JOINT DETAIL8TRUSS TO CMU WALL CONNECTION DETAIL6 GABLE END TRUSS BRACING DETAIL7
SD-1
SHEET
STAMP
PROJECT NO:
DATE:
SCALE:
DRAWN BY:
CHECKED BY:
26-007
2.23.26
CKC
CKC
D A
TE
RE
V
IS
IO
N
PR
O
V O
B A
TH
RO
O M
S
- Q
UA
IL
O
RC
HA
RD
B
A
TH
ST
RU
C
TU
RA
L
D
ET
A
IL
S
NTS