AE600_20210304.pdf

PDF 233 KB Posted

Attached to
Keating US Probation 2nd Fl Office Relocation - Construction Federal contract opportunity
Solicitation number
47PC0221R0011
Issued by
General Services Administration Public Buildings Service Region 2

About this file

This synopsis and solicitation opportunity describe a construction contract for office relocation work at the Keating Federal Building and Courthouse in Syracuse, New York. The General Services Administration seeks to award a firm fixed price contract valued between $1,000,000 and $5,000,000 to renovate approximately 9,800 square feet of space on the second floor to consolidate U.S. Probation offices currently located on the first floor. There are three bid options related to mechanical work, exterior finishes, and first floor renovations. The solicitation will be issued on February 10th with bids due on March 12th, and award is anticipated to be made to the responsible bidder offering the most advantageous proposal considering price and technical factors. The work must be completed within one hundred sixty-six calendar days of notice to proceed. The procurement is reserved exclusively for small business concerns and will utilize the design documents and specifications provided.

View the file

Other files for this federal contract opportunity

Other files attached to Keating US Probation 2nd Fl Office Relocation - Construction, newest first.
File Type Posted
Solicitation Amendment 47PC0221R0011_0002.pdf PDF
Amendment 2.pdf PDF
Keating RFI Responses 2.pdf PDF
EY001_20210304.pdf PDF
Keating RFI Responses.pdf PDF
Amendment 1.pdf PDF
Addendum_02.pdf PDF
Asbestos Survey Assessment Report.pdf PDF
Solicitation Amendment 47PC0221R0011_0001.pdf PDF
U.S. Probation Keating 2nd Fl Office Relocation- Construction Questions.pdf PDF
Site Visit sign in sheet.jpg JPG image
Attachment 4 Monroe WD NY20210010 1.05.21.pdf PDF
Rep and Certs for 47PC0221R0011 US Probation 2nd Floor Office Relocation.pdf PDF
Attachment 6 Past Performance Questionnaire Form.pdf PDF
Solicitation 47PC0221R0011 US Probation 2nd Floor Office Relocation.pdf PDF
SBU Clause and Form.pdf PDF
Contractors Qual and Financial Info GSA527-15c.pdf PDF
Bid Bond SF24-16d.pdf PDF
Attachment 7 Key Personnel Form.pdf PDF
47PC0221R0011 Form.pdf PDF
SBSA GC Agreement 47PC0221R0011 US Probation 2nd Floor Office Relocation.pdf PDF
Attachment 1 Proposal Breakdown Template.xlsx XLSX spreadsheet
Attachment 5 Experience on Similar Projects Offeror Form.xlsx XLSX spreadsheet
Attachment 8 Addendum 1 SOW.pdf PDF
Synopsis.pdf PDF
Show all 25

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TYPE H1

HOLLOW METAL

WELDED FRAME

2" 2"DOOR WIDTH

2"

2" 2"DOOR WIDTH

2"

TYPE EX H1

EXISTING HOLLOW METAL

WELDED FRAME

TYPE EX H2

EXISTING HOLLOW METAL

WELDED FRAME WITH

SIDELIGHT

2" 2"

DOOR WIDTH2"

SIDELIGHT WIDTH

2"

2"

0'

6" 2'

1"

0' - 4" 0' - 6"

TYPE N1

NARROW TEMPERED

VISION GLASS

TYPE FG

FULL GLASS,

TEMPERED, INSULATED

VISION GLASS, TOP AND

BOTTOM RAILS

0'

4" 0'

4"

TYPE F

FLUSH

NOTE: DOOR TYPES ARE GENERALLY BASED ON STEEL DOOR INSTITUE STANDARD STYLES

T1

• INTERIOR

• RUBBER TRANSITION STRIP

T3

• INTERIOR

• MARBLE THRESHOLD

T2

• INTERIOR

• RUBBER TRANSITION STRIP

• CARPET TILE TO RESILIENT TILE

SCHEDULED WALL

CONSTRUCTION

DOUBLE METAL

STUD HEADER

HOLLOW METAL

FRAME

SCHEDULED

DOOR

JAMB BEYOND

SCHEDULED WALL

CONSTRUCTION

DOUBLE METAL

STUD, FULL HEIGHT HOLLOW METAL

FRAME

SCHEDULED

DOOR

SE

E

PL

AN

S

VA

R

IE

S

SCHEDULED DOOR JAMB BEYOND

DOUBLE ANGLE

STEEL LINTEL

HOLLOW METAL

FRAME

LINTEL FLASHING AS

SPECIFIED

FULLY GROUT FRAME

SCHEDULED DOOR

FULLY GROUT FRAME

HOLLOW METAL FRAME

NKB

N. .______________________________________________________

ARCHITECTURE & ENGINEERING, PC..

K BHANDARI

RENOVATION

SHEET SIZE: 34 X 44

DRAWING NO.

CHECKED BY

DRAWN BY

FLOOR NO.

FILE NAME

DRAWING TITLE

SUB. DATE

SUBMISSION

GSA PM

PROJECT NO.

PROJECT

DESCRIPTION

PROJECT

TITLE

FACILITY CODE

OTHER

BUILDING NOs.

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

CONSTR. FIRM

SUB A/E

PRIME A/E

A/E CON. NO.

DR

AW

IN

G

PR

O

JE

CT

BU

IL

DI

NG

CO

NT

RA

CT

O

RS

G

RA

PH

IC

SC

AL

E

R

EV

IS

IO

N N

O

TE

S

CE

RT

IF

IC

AT

IO

NS

MARK DATE DESCRIPTION

SHEET OF

NK BHANDARI ARCHITECTURE

C&S ENGINEERS

GS-07-P-16-UC-D-7008

KE

Y

PL

AN

SENSITIVE BUT UNCLASSIFIED (SBU) PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

DATE:

A

SUB A/E

CONSTR. CON. -

NYS EDUCATION LAW, SECTION 7209 AND 69.5(B)

PROHIBITS ANY PERSON TO ALTER THESE DRAWINGS

OTHER THAN A LICENSED ARCHITECT OR THE DESIGN

ENGINEER. INFORMATION ON THESE DRAWINGS FOR

GSA ONLY, AND CAN BE UTILIZED BY GSA AS THEY

DEEM NECESSARY.

COPYRIGHT 2019

N. K. BHANDARI, ARCHITECTURE & ENGINEERING, P.C.

1005 W. Fayette Street, Suite 500 Syracuse, NY 13204

Phone Fax www.nkbpc.com

315.428.1177 315.428.9822

499 Col. Eileen Collins Blvd Syracuse, NY 13212

Phone www.cscos.com

315.455.2000

U.S. General Services Administration

100 STATE STREET

ROCHESTER, NY 14614

B

C

D

3 4 51

C:\Users\pdd\Documents\R20_GSA Keating 2nd Floor Probation_CENTRAL_pdudkowskiD8JHD.rvt

3/ 5/

0:

:3

AM

SCHEDULES AND DIAGRAMS

PROBATION 2ND FLOOR

OFFICE RELOCATION

PDD

JLHS 08-26-2020

16320.94

08-26-2020

26 71

FOR CONSTRUCTION

AE600

ERIN BISHOP

KEATING FEDERAL BUILDING

DOOR SCHEDULE

DOOR

NUMBER ROOM NAME

ROOM

NUMBER

DOOR FRAME

THRESHOLD

FIRE

RATING REMARKS

HARDWARE

SET

DOOR

NUMBERWIDTH HEIGHT THICKNESS LEAF SIZE TYPE

DOOR

MATERIAL FINISH FRAME TYPE

FRAME

MATERIAL FRAME FINISH

FRAME

DETAIL

SECOND FLOOR

201 WAITING 201 6' - 0" 7' - 0" 0' - 1 3/4" 36/36 FG GLASS BRASS TRIMS FRAMELESS - - - T1 - 1, 4, 5 4 201 202 WOMEN'S 202 3' - 0" 7' - 0" 0' - 1 3/4" 36 F WD STN1 EX H1 EX HM PNT2 - T3 - 5 202 203 MEN'S 203 3' - 0" 7' - 0" 0' - 1 3/4" 36 F WD STN1 EX H1 EX HM PNT2 - T3 - 5 203 204 FILE 204 3' - 0" 7' - 0" 0' - 1 3/4" 36 F WD STN1 EX H1 EX HM PNT2 - T1 - 6 204

205C CONFERENCE ROOM 205 3' - 0" 7' - 0" 0' - 1 3/4" 36 N1 HM PNT2 EX H1 EX HM PNT2 - T1 - 5 7 205C 206 MEDIA / MAIL ROOM 206 3' - 0" 7' - 0" 0' - 1 3/4" 36 F WD STN1 H1 HM PNT2 1 & 2/ AE600 T1 - 6 206 207 CORRIDOR 244 3' - 0" 7' - 0" 0' - 1 3/4" 36 F WD STN1 EX H1 EX HM PNT2 - T1 - 1 8 207

237 DISTRICT COMPUTER

ROOM

237 3' - 0" 7' - 0" 0' - 1 3/4" 36 F WD STN1 EX H1 EX HM PNT2 - T2 - 1 9 237

238 GUN LOCKER 238 3' - 0" 7' - 0" 0' - 1 3/4" 36 F WD STN1 H1 HM PNT2 1 & 2/ AE600 T1 - 1 8 238 239A CORRIDOR 240 3' - 0" 7' - 0" 0' - 1 3/4" 36 N1 WD STN1 H1 HM PNT2 1 & 2/ AE600 T2 - 3, 5 14 239A 239B CORRIDOR 239 3' - 0" 7' - 0" 0' - 1 3/4" 36 F WD STN1 EX H1 EX HM PNT2 - T2 - 7 239B 239C CORRIDOR 239 3' - 0" 7' - 0" 0' - 1 3/4" 36 F WD STN1 EX H1 EX HM PNT2 - T2 - 5 7 239C 241 CORRIDOR 241 3' - 0" 7' - 0" 0' - 1 3/4" 36 F WD STN1 EX H2 EX HM PNT2 - T1 - 1, 5 10 241

DOOR HARDWARE SCHEDULE

QTY ITEM BOD MFR DESCRIPTION

FINIS

H

SET 1

1 TRACK ASSEMBLY DIRTT SLIDING SYSTEM WITH

HYDRAULIC BRAKE

ALUM

1 LOCKSET (OFFICE) DIRTT TBD 26D

1 CYLINDER (ONLY) SARGENT 6300 26D

1 DOOR SEAL / SWEEP DIRTT WITH DOOR SLIDING SYSTEM GREY

SET 2

1 TRACK ASSEMBLY DIRTT SLIDING SYSTEM WITH

HYDRAULIC BRAKE

ALUM

2 PULL LOCKSET (PASSAGE) DIRTT TBD 26D

1 DOOR SEAL / SWEEP DIRTT WITH DOOR SLIDING SYSTEM GREY

SET 3

3 HINGES (OFFSET) DIRTT PATCH HINGE US26D

1 LOCKSET (OFFICE) DIRTT TBD US26D

1 CYLINDER (ONLY) SARGENT 6300 US26D

1 AUTOMATIC DROP SEAL DIRTT SINGLE ACTUATION BLACK

1 DOOR SEAL DIRTT SINGLE ACTUATION BLACK

1 WALL STOP ROCKWOOD 409 US32D

SET 3a

3 HINGES (OFFSET) DIRTT PATCH HINGE US26D

1 LOCKSET (PASSAGE) DIRTT TBD US26D

1 AUTOMATIC DROP SEAL DIRTT SINGLE ACTUATION BLACK

1 DOOR SEAL DIRTT SINGLE ACTUATION BLACK

1 WALL STOP ROCKWOOD 409 US32D

SET 4

4 HINGES CRL CENTER HUNG TOP AND

BOTTOM PIVOTS

US3

2 TOP RAIL CRL DOOR RAIL 1/2" GLASS

SQUARE EDGE DR4SPB12S

US3

2 BOTTOM RAIL CRL DOOR RAIL 1/2" GLASS WTH

LOCK SQUARE EDGE

DR4SPB12S

US3

2 FLOOR LOCK CRL DOOR RAIL FLOOR LOCK

STANDARD MORTISE LOCK

777S

US3

2 DUSTPROOF FLOOR STRIKE CRL DUSTPROOF KEEPER WITH

MOUNTING PLATE AMR209BR

US3

2 EXIT DEVICE CRL / BLUMCRAFT PA100 SERIES PANIC, RAIL

MOUNT

US3

2 INTERIOR HANDLE CRL / BLUMCRAFT TOP LATCHING PANIC WITH

EGRESS HANDLE

US3

2 EXTERIOR HANDLE CRL / BLUMCRAFT HANDLE Y US3

2 CYLINDER TBD TBD US3

1 HEADER CRL HEADER FOR OVERHEAD

CONCEALED CLOSER

DCH4PBD

US3

2 CLOSER CRL / JACKSON OVERHEAD CONCEALED

CLOSER 21201P62801

NA

1 ELECTRIC STRIKE CRL HEAD MOUNTED WITH ESP2

DOOR POSITION SENSOR

US3

1 PROXIMITY READER BY OWNER BY OWNER TBD

2 WALL STOP ROCKWOOD 406 US3

SET 5

3 HINGES MCKINNEY T4A3786 4 1/2 x 4 1/2 26D 1 PULL ROCKWOOD RM7410 1.25" x 11" 26D 1 PUSH ROCKWOOD 73A 3" x 12" x 0.125" 26D

1 CLOSER LCN 4040 26D

1 WALL STOP ROCKWOOD 406 26D

3 SILENCER IVES /

GLYNN-JOHNSON

SR 64 GREY

SET 6

3 HINGES MCKINNEY T4A3786 4 1/2 x 4 1/2 26D

1 LOCKSET (STORAGE) SARGENT 10G04-G-P-26D 26D

1 CLOSER LCN 4040 26D

1 WALL STOP ROCKWOOD 406 26D

3 SILENCER IVES /

GLYNN-JOHNSON

SR 64 GREY

SET 7

3 HINGES MCKINNEY T4A3786 4 1/2 x 4 1/2 NRP 26D

1 LOCKSET (STORAGE) SARGENT 10G04-G-P-26D 26D

1 ELECTRIC STRIKE HES 7000 (FAIL SAFE) 26D

1 CLOSER LCN 4040 26D

1 PROXIMITY READER BY OWNER TBD BLACK

1 DOOR CONTACT INTERLOGIX / GE 1076D-N TBD

1 WALL STOP ROCKWOOD 406 26D

3 SILENCER IVES /

GLYNN-JOHNSON

SR 64 GREY

SET 8

3 HINGES MCKINNEY T4A3786 4 1/2 x 4 1/2 NRP 26D

1 LOCKSET (STORAGE) SARGENT 10G04-G-P-26D 26D

1 ELECTRIC STRIKE HES 7000 26D

1 CLOSER LCN 4040 26D

1 PROXIMITY READER BY OWNER TBD TBD

1 DOOR CONTACT INTERLOGIX / GE 1076D-N BLACK

1 WALL STOP ROCKWOOD 406 26D

3 SILENCER IVES /

GLYNN-JOHNSON

SR 64 GREY

SET 9

3 HINGES MCKINNEY T4A3786 4 1/2 x 4 1/2 NRP 26D

1 LOCKSET (STORAGE) SARGENT 10G04-G-P-26D 26D

1 ELECTRIC STRIKE HES 7000 26D

1 CLOSER LCN 4040 26D

1 PROXIMITY READER BY OWNER TBD TBD

1 DOOR CONTACT INTERLOGIX / GE 1076D-N BLACK

1 OVERHEAD STOP IVES 90S 26D

3 SILENCER IVES /

GLYNN-JOHNSON

SR 64 GREY

SET 10

3 HINGES MCKINNEY T4A3786 4 1/2 x 4 1/2 NRP 26D

1 LOCKSET (ENTRANCE) SARGENT 10G05-G-P-26D 26D

1 ELECTRIC STRIKE HES 7000 26D

1 CLOSER LCN 4040 26D

1 PROXIMITY READER BY OWNER TBD TBD

1 DOOR CONTACT INTERLOGIX / GE 1076D-N BLACK

3 SILENCER IVES /

GLYNN-JOHNSON

SR 64 GREY

SET 11

3 HINGES MCKINNEY T4A3786 4 1/2 x 4 1/2 NRP 26D

1 LOCKSET (STORAGE) SARGENT 10G04-G-P-26D 26D

1 ELECTRIC STRIKE HES 7000 26D

1 CLOSER LCN 4040 26D

1 PROXIMITY READER BY OWNER TBD TBD

1 DOOR CONTACT INTERLOGIX / GE 1076D-N BLACK

1 WALL STOP ROCKWOOD 406 26D

3 SILENCER IVES /

GLYNN-JOHNSON

SR 64 GREY

SET 12

6 HINGES MCKINNEY T4A3786 4 1/2 x 4 1/2 26D

2 EXIT DEVICE (VERTICAL ROD) VON DUPRIN 99-27-LDT-06-F-3'-US26 26D

2 CLOSER LCN 4040 26D

2 MAGNETIC HOLD OPEN LCN SEM7840 AL (FAILSAFE) 26D

2 SILENCER IVES /

GLYNN-JOHNSON

SR 64 GREY

2 SMOKE RATED GASKETING

PERIMETER

PEMKO 29344 NB ALUM

2 SMOKE RATED DOOR

BOTTOM

PEMKO 411_NBL ALUM

SET 13

3 HINGES MCKINNEY T4A3786 4 1/2 x 4 1/2 NRP 26D

1 LOCKSET (STORAGE) SARGENT 10G04-G-P-26D 26D

1 ELECTRIC STRIKE HES 7000 26D

1 CLOSER LCN 4040 26D

1 PROXIMITY READER BY OWNER TBD TBD

1 DOOR CONTACT INTERLOGIX / GE 1076D-N BLACK

1 OVERHEAD STOP IVES 90S 26D

3 SILENCER IVES /

GLYNN-JOHNSON

SR 64 GREY

1 SMOKE RATED GASKETING

PERIMETER

PEMKO 29344 NB ALUM

1 SMOKE RATED DOOR

BOTTOM

PEMKO 411_NBL ALUM

SET 14

1 HINGES (SET) MCKINNEY JAMB MOUNTED PIVOT EP-5 32D

1 ROLLER CATCH ROCKWOOD 910 26D

1 LATCHSET SARGENT 10G94-2-G-P-26D (DUMMY) 26D

1 CLOSER LCN 4040 (DUAL ACTING) 26D

1 DOOR GASKETING PEMKO 5041_NB BRUSH SEAL /

MORTISE

ALUM

1 BOTTOM SWEEP PEMKO 434 NBL BRUSH SEAL

AUTOMATIC DOOR BOTTOM

ALUM

DOOR FRAME TYPES

DOOR TYPES

THRESHOLDS

DOOR SCHEDULE NOTES

1 ALL DOORS TO BE 1 ¾” THICK X 84” HIGH UON. ALL FRAMES TO BE 16 GA FULLY WELDED

HOLLOW METAL. PROVIDE ANCHORAGE TYPE TO SUIT WALL CONSTRUCTION. ALL FRAMES

TO OVERLAP WALL FINISH. PROVIDE 20 GA STUDS AT JAMBS IN GYPSUM BOARD WALLS.

2 ALL VISION PANELS IN RATED DOORS AND FRAMES TO BE ¼” THICK WIREGLASS UON. ALL

VISION PANELS IN NON-RATED DOORS AND FRAMES TO BE LAMINATED SAFETY GLASS UON.

ALL EXTERIOR DOOR LIGHTS, TRANSOMS, AND SIDELIGHTS TO BE 1” INSULATING TEMPERED

GLASS UON.

3 WHERE RATED DOORS ARE INDICATED, DOOR FRAME RATING TO EQUAL DOOR RATING.

FRAMES FOR WINDOWS INSTALLED IN RATED PARTITIONS TO BE RATED SAME AS DOOR

FRAMES AND BE COMPATIBLE WITH WALL TYPE.

4 “EX” AT SCHEDULE DENOTES EXISTING. VERIFY HEIGHT & WIDTH IN FIELD.

5 DOOR WIDTH IS INDICATED IN INCHES. TWO NUMBERS SEPARATED BY A SLASH (/) INDICATES

DOUBLE DOORS.

6 UL LABELS: A LABEL = 3 HOURS

B LABEL = 1 ½ HOURS

C LABEL = ¾ HOUR

7 FINISHED DOOR OPENINGS SHALL BE NOMINAL 6” FROM FINISHED CORNER OF ROOM AT

HINGE SIDE, EXCEPT WHERE DIMENSIONED OTHERWISE. ON THE “PULL” SIDE OF A DOOR

OPENING, THE STRIKE SIDE SHALL BE NOMINAL 18” FROM A PERPENDICULAR WALL. ON THE

“PUSH” SIDE OF A DOOR OPENING EQUIPPED WITH BOTH A CLOSER AND LATCH, THE STRIKE

SIDE SHALL BE NOMINAL 12” FROM A PERPENDICULAR WALL.

8 ALL MASONRY OPENINGS TO RECEIVE LINTELS. SEE LINTEL SCHEDULE.

9 DOOR SECURITY SEQUENCE OF OPERATION TO BE FINISHED WITH OWNER.

DOOR SCHEDULE REMARKS

Key

Name DOOR SCHEDULE REMARKS

1 ELECTRONIC SECURITY - REFER TO HARDWARE SETS AND SECURITY DRAWINGS

2 MAGNETIC LOCK

3 DOOR FRAME TO BE ROVIDED WITHOUT DOOR STOPS TO ALLOW FOR DUAL SWING / DOUBLE

ACTING DOOR

4 PROVIDE AGENCY GRAPHIC ON GLAZING. COORDINATE WITH PROPERTY MANAGER.

5 PROVIDE FULL PERIMETER ACOUSTIC GASKETING AT FRAME AND AT BOTTOM OF DOOR.

BID OPTION 3 - WINDOW SCHEDULE

MARK HT WIDTH GLAZING DESCRIPTION

W1 4' - 9" 3' - 0" SECURITY GLAZING 088853 TRANSACTION SECURITY WINDOW

085123.23

W2 4' - 0" 4' - 0" SECURITY GLAZING 088853 TRANSACTION SECURITY WINDOW

085123.23

WINDOW TREATMENT SCHEDULE

MARK MFR MODEL COUNT COMMENTS

WT1 LEVOLOR MARK 1 38 4'-9" +/-

WT2 LEVOLOR MARK 1 6 4'-0" +/-

WT3 LEVOLOR MARK 1 19 3'-9" +/-

WT4 LEVOLOR MARK 1 2 6'-3" +/-

Grand total: 65

DOOR SCHEDULE - DIRTT DOORS

DOOR

NUMBER ROOM NAME

ROOM

NUMBER

DOOR

THRESHOLD

FIRE

RATING

HARDWARE

SET

DOOR

NUMBERTYPE

DOOR

MATERIAL

SECOND FLOOR

205A CONFERENCE ROOM 205 SLIDING GLAZ - 2 205A

205B CONFERENCE ROOM 205 SLIDING GLAZ - 2 205B

208 PO 10 OFFICE 208 SLIDING GLAZ - 1 208

209 PO 9 OFFICE 209 SLIDING GLAZ - 1 209

210 PO 8 OFFICE 210 SLIDING GLAZ - 1 210

211 SUPERVISOR 1 OFFICE 211 SWINGING GLAZ - 3 211

212 PO 6 OFFICE 212 SLIDING GLAZ - 1 212

213 PO 5 OFFICE 213 SLIDING GLAZ - 1 213

214 VISITING IWI OFFICE 4 214 SLIDING GLAZ - 1 214

215 PO 4 OFFICE 215 SLIDING GLAZ - 1 215

216 CORRIDOR 245 SLIDING GLAZ - 1 216

217 PO 3 OFFICE 217 SLIDING GLAZ - 1 217

218 VISITNG IWI OFFICE 2 218 SLIDING GLAZ - 1 218

219 PO 2 OFFICE 219 SLIDING GLAZ - 1 219

220 VISITING IWI OFFICE 1 220 SLIDING GLAZ - 1 220

221 PO 1 OFFICE 221 SLIDING GLAZ - 1 221

222 CHIEF OFFICE 222 SWINGING GLAZ - 3 222

223 SUPERVISOR 2 OFFICE 223 SLIDING GLAZ - 1 223

224 PO 11 OFFICE 224 SLIDING GLAZ - 1 224

225 PO 12 OFFICE 225 SLIDING GLAZ - 1 225

226 PO 13 OFFICE 226 SLIDING GLAZ - 1 226

227 PO 14 OFFICE 227 SLIDING GLAZ - 1 227

228 SUPERVISOR 3 OFFICE 228 SLIDING GLAZ - 1 228

229 PO 15 OFFICE 229 SLIDING GLAZ - 1 229

230 PO 16 OFFICE 230 SLIDING GLAZ - 1 230

231 PO 17 OFFICE 231 SLIDING GLAZ - 1 231

232 PO 18 OFFICE 232 SLIDING GLAZ - 1 232

233 PO 19 OFFICE 233 SLIDING GLAZ - 1 233

234 PO 20 OFFICE 234 SLIDING GLAZ - 1 234

235 PO 21 OFFICE 235 SLIDING GLAZ - 1 235

236 BREAK ROOM 236 SWINGING GLAZ - 3a 236

1 1/2" = 1'-0"AE600

1 HM DOOR HEAD DETAIL (GWB)

1 1/2" = 1'-0"AE600

2 HM DOOR JAMB DETAIL (GWB)

1 1/2" = 1'-0"AE600

3 DOOR HEAD DETAIL (CMU)

1 1/2" = 1'-0"AE600

4 DOOR JAMB DETAIL (CMU)

BID OPTION 3 - DOOR SCHEDULE

DOOR

NUMBER ROOM NAME

ROOM

NUMBER

DOOR FRAME

THRESHOLD

FIRE

RATING REMARKS

HARDWARE

SET

DOOR

NUMBERWIDTH HEIGHT THICKNESS LEAF SIZE TYPE

DOOR

MATERIAL FINISH FRAME TYPE

FRAME

MATERIAL FRAME FINISH

FRAME

DETAIL

FIRST FLOOR

102 RECEPTION 102 3' - 0" 7' - 0" 0' - 1 3/4" 36 F HM PNT2 / PNT5 H1 HM PNT2 / PNT5 3 & 4/ AE600 T2 - 1, 5 13 102

105B INTERVIEW 105 3' - 0" 7' - 0" 0' - 1 3/4" 36 N1 HM PNT2 H1 HM PNT2 1 & 2/ AE600 - - 1 8 105B 106B INTERVIEW 106 3' - 0" 7' - 0" 0' - 1 3/4" 36 N1 HM PNT2 H1 HM PNT2 1 & 2/ AE600 - - 1 8 106B 107 FILE STORAGE 107 3' - 0" 7' - 0" 0' - 1 3/4" 36 F HM PNT2 H1 HM PNT2 1 & 2/ AE600 - - 6 107

108A PROCESSING 108 3' - 0" 7' - 0" 0' - 1 3/4" 36 N1 HM PNT2 H1 HM PNT2 1 & 2/ AE600 - - 1 8 108A 108B PROCESSING 108 3' - 0" 7' - 0" 0' - 1 3/4" 36 N1 HM PNT2 H1 HM PNT2 1 & 2/ AE600 - - 1 8 108B 113B CORRIDOR 113 3' - 0" 7' - 0" 0' - 1 3/4" 36 F HM PNT2 H1 HM PNT2 1 & 2/ AE600 T2 - 1, 5 11 113B 114 CORRIDOR 114 3' - 0" 7' - 0" 0' - 1 3/4" 36 N1 HM PNT2 H1 HM PNT2 1 & 2/ AE600 - - 1 8 114 115 CORRIDOR 115 5' - 0" 7' - 0" 0' - 1 3/4" 30/30 F HM PNT2 H1 HM PNT2 1 & 2/ AE600 - - 12 115

2 3/4/2021 ADDENDUM #2

90 MIN.

90 MIN.

Sheets
AE600 - SCHEDULES AND DIAGRAMS

File details come from the government source that posted it. Updated .