36E77619B0003-007.pdf
PDF 14 MB Posted
- Solicitation number
- 36E77619B0003
About this file
36E77619B0003 ATTACHMENT 7 - Drawings 3 of 7.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36E77619C0023-000.docx | DOCX document | |
| 36E77619B0003-0003002.pdf | ||
| 36E77619B0003-0003003.pdf | ||
| 36E77619B0003-0003004.pdf | ||
| 36E77619B0003-0003005.pdf | ||
| 36E77619B0003-0003000.docx | DOCX document | |
| 36E77619B0003-0003006.pdf | ||
| 36E77619B0003-0003001.pdf | ||
| 36E77619B0003-0002000.docx | DOCX document | |
| 36E77619B0003-0001001.pdf | ||
| 36E77619B0003-0001000.docx | DOCX document | |
| 36E77619B0003-000.docx | DOCX document | |
| 36E77619B0003-013.docx | DOCX document | |
| 36E77619B0003-005.pdf | ||
| 36E77619B0003-012.pdf | ||
| 36E77619B0003-002.pdf | ||
| 36E77619B0003-006.pdf | ||
| 36E77619B0003-009.pdf | ||
| 36E77619B0003-011.pdf | ||
| 36E77619B0003-001.pdf | ||
| 36E77619B0003-003.pdf | ||
| 36E77619B0003-010.pdf | ||
| 36E77619B0003-004.pdf | ||
| 36E77619B0003-008.pdf | ||
| 36E77619B0003.docx | DOCX document |
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SUPPLEMENTAL LOAD LEGEND
JOIST GIRDER
(##K)
ADDITIONAL LOAD AT
INDICATED JOIST
GIRDER PANEL POINT
NOTES:
1) LOAD IS ASD LIVE LOAD (KIPS), UNO.
2) LOAD IS IN ADDITION TO TYPICAL PANEL POINT LOADS, UNO.
3) LATERAL FORCE TO BE TRANSFERRED THROUGH SUPPORT BY CONNECTIONS, IN
ADDITION TO VERTICAL REACTION FORCES. FORCE MAY ACT IN EITHER DIRECTION.
4) TOP CHORD AXIAL FORCE IN ADDITION TO CHORD FORCES PRODUCED BY VERTICAL LOADS. FORCE
MAY BE EITHER COMPRESSION OR TENSION.
##K
JO
IS
T , T
Y P
#K
NOTE 3
NOTE 4
MISCELLANEOUS SYMBOLS
NORTH ARROW
GRIDLINES
EARTH
SECTION NUMBER
SHEET NUMBER
S101
S101
CALLOUT NUMBER
SHEET NUMBER
A
ELEVATION REFERENCE
LIMIT OF EXTENT
CONTINUOUS EXTENT
F ## COLUMN FOOTING NOTATION
GB ## GRADE BEAM NOTATION
P ## PIER NOTATION
B ## CONCRETE BEAM NOTATION
PC ## PILE CAP NOTATION
WF ## WALL FOOTING NOTATION
SHEAR WALL NOTATIONSW ##
BW ## BEARING WALL NOTATION
GRAVEL
Name
Elevation
TF ## TRENCH FOOTING NOTATION
FLOOR DRAIN
FD
N 3" ROOF DECK
DIRECTION OF SPAN
CONCRETE SYMBOLS
REBAR
CHANGE OF SLAB
ELEVATION
SLOPING SLAB
CHANGE OF SLAB
THICKNESS
MECHANICAL COUPLER
REBAR SPLICE
LIMIT OF MEMBER OR
SPAN MARK
DIRECTION OF SPAN
OPENING
SELF-EXPANDING
WATERSTOP
CONTROL JOINT LOCATION
IN CONCRETE WALLS
REBAR TERMINATOR
INTENTIONALLY
ROUGHENED
CONSTRUCTION JOINT
TO 1/4" AMPLITUDE
PVC WATERSTOP
COLUMN CONTINUES
COLUMN TERMINATED
FORM-SAVER
CONNECTORS
HEADED STUD
CONNECTOR SECTION END/ALT VIEW
CAST-IN ANCHOR
ROD
POST-INSTALLED
MECHANICAL ANCHOR
BOLT
POST INSTALLED
ADHESIVE ANCHOR
MASONRY MEMBERS
SINGLE REINFORCEMENT
(FULLY GROUT REINFORCED CELLS)
DOUBLE REINFORCEMENT
(FULLY GROUT REINFORCED CELLS
CMU BLOCK
CMU BOND BEAM
(FULLY GROUTED)
CMU LINTEL
(FULLY GROUTED)
EQ
EQ
EQ
EQ
EQ
th re e-qu ar te rs in ch o ne fo ot on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot
B th re e in ch es o ne fo ot
SCALE
PROJECT PRINCIPAL
PROJECT ARCHITECT
ELECTRICAL ENGINEER
PROJECT MANAGER
MECHANICAL ENGINEER
Use or disclosure of data contained on this sheet is subject to the restriction on the title page of this proposal.
Robinson
Robinson
Fischer
Gobreski
Daller
Danville, IL
Drawing Title
Approved:
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
B
A
C
D
E
F
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veteran Affairs
LANDSCAPE ARCHITECT
CIVIL ENGINEER
STRUCTURAL ENGINEER
Cyr
Meneley
VanderWoude
PLUMBING ENGINEER Daller
CONSTRUCTION DOCUMENTS 06/21/2017
550-316
One Indiana Square, Suite 2100 Indianapolis, IN 46204
United States P: 317 532 5400 F: 317 532 5499 www.URScorp.com
/1
/2
:1 :1
P
M C
U s e rs \b th o m a s \ D o c u m e n ts
\1 .1
V A
D a n v ill e G re e n H o m e s b th o m a s .r v t
SI001
ABBREVIATIONS AND SYMBOLS
WJTMAV2017.06.21
VA DANVILLE - CONSTRUCT TWO
GREEN HOMES
URS PROJECT NO. 25628010
J/BRG JOIST BEARING
JST JOIST
JT JOINT
KB KNEE BRACE
KIP, K 1,000 POUNDS
KO KNOCK-OUT
KSI KIPS PER SQUARE INCH
L ANGLE OR LENGTH
LAB LABORATORY
LB POUND
LF LINEAL FOOT
LIN LINEAL, LINEAR
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONGIT LONGITUDINAL
LP LOW POINT
LSLT LONG SLOTTED HOLE
LT LAMINATED TIMBER
LTWT LIGHT WEIGHT
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MB MACHINE BOLT
MC MISCELLANEOUS CHANNEL
MECH MECHANICAL
MEMB MEMBRANE
MEP MECHANICAL/ ELECTRICAL/ PLUMBING
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MULT MULTIPLE
N/A NOT APPLICABLE
NO NUMBER
NOM NOMINAL
NS NEAR SIDE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OFD OVERFLOW DRAIN
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OPPHD OPPOSITE HAND
ORIG ORIGINAL
OVS OVERSIZED HOLE
P PIER
PC PIER CAP OR PRECAST
PERIM PERIMETER
PERM PERMANENT
PERP PERPENDICULAR
PJP PARTIAL JOINT PENETRATION
PL PLATE
PLF POUNDS PER LINEAL FOOT
PLYWD PLYWOOD
PREFAB PREFABRICATED
PREL PRELIMINARY
PREP PREPARATION, PREPARE
PROJ PROJECTION
PS PRESTRESSED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSL PARALLEL STRAND LUMBER
PT POST-TENSIONED
R RADIUS
RD ROOF DRAIN
REF REFERENCE
REINF REINFORCEMENT, REINFORCE
REQD REQUIRED
RO ROUGH OPENING
SCH SCHEDULE
SECT SECTION
SF SQUARE FEET
SHT SHEET
SIM SIMILAR
SL SLOPE
SL-DN SLOPE DOWN
SL-UP SLOPE UP
SOG SLAB-ON-GRADE
SP SHEET PILING
SPA SPACES, SPACE
SPECS SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
SSLT SHORT SLOTTED HOLE
STD STANDARD
STIFF STIFFENER
STL STEEL
STRUC STRUCTURAL
SYM SYMMETRICAL
T & B TOP AND BOTTOM
T/ TOP OF
T/GB TOP OF GRADE BEAM
TBS MECHANICAL TENSION BUTT SPLICE
TEMP TEMPERATURE
TF TRENCH FOOTING
THRU THROUGH
TRANS TRANSVERSE
TYP TYPICAL
UL UNDERWRITERS' LABORATORY INC.
UNO UNLESS NOTED OTHERWISE
UT ULTRA-SONIC TEST
VERT VERTICAL
W WIDE FLANGE
W/ WITH
W/O WITHOUT
WD WOOD
WF WALL FOOTING
WP WORK POINT
WWF WELDED WIRE FABRIC
A/E ARCHITECT/ENGINEER
ACI AMERICAN CONCRETE INSTITUTE
ACP AUGER CAST PILE
ADDL ADDITIONAL
ADJ ADJACENT
AGGR AGGREGATE
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALT ALTERNATE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
APPROX APPROXIMATE
AR ANCHOR ROD
ARCH ARCHITECTURAL
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
AWS AMERICAN WELDING SOCIETY
B/ BOTTOM OF
BAL BALANCE
BD BOARD
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BOTT BOTTOM
BRG BEARING
BRKT BRACKET
BTWN BETWEEN
C STANDARD CHANNEL
CANT CANTILEVER
CC CENTER TO CENTER
CF COLD FORMED
CG CENTER OF GRAVITY
CIP CAST-IN-PLACE
CJ CONTROL JOINT OR CONSTRUCTION JOINT
CJP COMPLETE JOINT PENETRATION
CL CENTERLINE
CLR CLEARANCE, CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
CTR CENTER
CTRD CENTERED
CU FT CUBIC FEET
CU IN CUBIC INCH
CYD CUBIC YARD
CW CONCRETE WALL
DBL DOUBLE
DEG DEGREE
DEMO DEMOLITION, DEMOLISH
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIAG DIAGONAL
DIAPH DIAPHRAGM
DIM DIMENSION
DN DOWN
DO DITTO
DP DRILLED PIER OR DEEP
DWG DRAWING
DWL DOWELS
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL, ELEV ELEVATION
ELEC ELECTRICAL
ENCL ENCLOSURE
ENGR ENGINEER
EOD EDGE OF DECK
EOJ EDGE OF JOIST
EOS EDGE OF SLAB
EQ EQUAL
EQPT EQUIPMENT
ES EACH SIDE
EW EACH WAY
EX EXISTING
EXP EXPANSION
EXT EXTERIOR
FAB FROM ADJACENT BEAM
FD FLOOR DRAIN
FDN FOUNDATION
FIN FINISH
FLG FLANGE
FLR FLOOR
FS FOOTING STEP
FT FEET
FTG FOOTING
FTGD FOOTING DRAIN
FV FIELD VERIFY
GA GAUGE
GALV GALVANIZED
GB GRADE BEAM
GRND GROUND
GT GIRDER TRUSS
HAS, HS HEADED ANCHOR STUD
HK HOOK
HORIZ HORIZONTAL
HP HIGH POINT
HS HOLLOW STRUCTURAL SECTION
HT HIP TRUSS
HVAC HEATING, VENTILATION, AIR CONDITIONING
ID INSIDE DIAMETER
IF INSIDE FACE
IN INCH
INCL INCLUDE
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
STRUCTURAL DRAWINGS ABBREVIATIONS
STRUCTURAL SHEET LIST
SHEET NUMBER SHEET NAME
SI001 ABBREVIATIONS AND SYMBOLS
SI002 STRUCTURAL GENERAL NOTES
SB101 INDEPENDENCE - FOUNDATION PLAN
SB102 INDEPENDENCE - SLAB PLAN
SB111 COURAGE - FOUNDATION PLAN
SB112 COURAGE - SLAB PLAN
SB301 FOUNDATION DETAILS
SF101 INDEPENDENCE - FIRST FLOOR FRAMING PLAN
SF102 INDEPENDENCE - ROOF FRAMING PLAN
SF111 COURAGE - FIRST FLOOR FRAMING PLAN
SF112 COURAGE - ROOF FRAMING PLAN
SF201 TRUSS PROFILES
SF202 TRUSS PROFILES
SF501 FRAMING DETAILS
SF921 STRUCTURAL ISOMETRICS
132 & 133 eric.slaughter Text Box th re e-qu ar te rs in ch o ne fo ot on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot
B th re e in ch es o ne fo ot
SCALE
PROJECT PRINCIPAL
PROJECT ARCHITECT
ELECTRICAL ENGINEER
PROJECT MANAGER
MECHANICAL ENGINEER
Use or disclosure of data contained on this sheet is subject to the restriction on the title page of this proposal.
Robinson
Robinson
Fischer
Gobreski
Daller
Danville, IL
Drawing Title
Approved:
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
B
A
C
D
E
F
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veteran Affairs
LANDSCAPE ARCHITECT
CIVIL ENGINEER
STRUCTURAL ENGINEER
Cyr
Meneley
VanderWoude
PLUMBING ENGINEER Daller
CONSTRUCTION DOCUMENTS 06/21/2017
550-316
One Indiana Square, Suite 2100 Indianapolis, IN 46204
United States P: 317 532 5400 F: 317 532 5499 www.URScorp.com
/1
/2
:1 :1
P
M C
U s e rs \b th o m a s \ D o c u m e n ts
\1 .1
V A
D a n v ill e G re e n H o m e s b th o m a s .r v t
SI002
STRUCTURAL GENERAL NOTES
WJTMAV2017.06.21
VA DANVILLE - CONSTRUCT TWO
GREEN HOMES
URS PROJECT NO. 25628010
GENERAL
THE STRUCTURE HAS BEEN DESIGNED FOR THE IN-SERVICE LOADS ONLY. THE
METHODS, MEANS, PROCEDURES, AND SEQUENCES OF CONSTRUCTION ARE THE
RESPONSIBILITY OF THE CONTRACTOR. THE STRUCTURE IS DESIGNED TO BE
SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND
SEQUENCE TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING
ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING,
TEMPORARY BRACING, GUYS AND TIEDOWNS.
THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH CIVIL,
ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS AND
SPECIFICATIONS.
THE GENERAL NOTES ON THE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH
THE FULL WRITTEN MATERIAL SPECIFICATIONS (IF ANY) FOR THE PROJECT. IF A
DISCREPANCY OCCURS BETWEEN THE NOTES AND THE FULL SPECIFICATIONS, THE
MORE STRINGENT REQUIREMENT SHALL APPLY.
NO PENETRATIONS THROUGH STRUCTURAL ELEMENTS, OTHER THAN THOSE SHOWN
ON THE DRAWINGS, SHALL BE MADE WITHOUT THE APPROVAL OF THE STRUCTURAL
ENGINEER.
CONCRETE MIX DESIGN SUBMITTAL
THE CONTRACTOR SHALL SUBMIT FOR THE REVIEW OF THE STRUCTURAL ENGINEER
A MIX DESIGN FOR EACH PROPOSED CLASS OF CONCRETE. EACH MIX DESIGN SHALL
BE IDENTIFIED BY A MIX NUMBER OR OTHER UNIQUE IDENTIFICATION. THE
CONTRACTOR SHALL NOT VARY FROM THE MIX DESIGNS NOR USE ANY CONCRETE
OTHER THAN THE APPROVED MIX DESIGNS WITHOUT THE APPROVAL OF THE
STRUCTURAL ENGINEER. MIX DESIGN SUBMITTALS SHALL INCLUDE THE FOLLOWING
INFORMATION:
1. MIX DESIGN NUMBER OR UNIQUE IDENTIFICATION AND INTENDED LOCATION OF PLACEMENT.
2. CEMENT TYPE, PROPORTION AND NAME OF MANUFACTURER.
3. FLY ASH PROPORTION (WHEN USED), LABORATORY ANALYSIS CERTIFICATION, AND NAME AND LOCATION OF
SUPPLIER.
4. COURSE AGGREGATE PROPORTION, GRADATION REPORT, NAME AND LOCATION OF SUPPLIER.
5. FINE AGGREGATE PROPORTION, GRADATION REPORT, NAME AND LOCATION OF SUPPLIER.
6. MIXING WATER PROPORTION AND SOURCE.
7. ADMIXTURE DOSAGES, PRODUCT NAME(S) AND MANUFACTURER NAME(S).
8. FIBER REINFORCEMENT DOSAGE (WHEN USED), PRODUCT NAME AND MANUFACTURER NAME.
9. DESIGN 28-DAY COMPRESSIVE STRENGTH (F'C).
10. DESIGN SLUMP RANGE.
11. DESIGN AIR-ENTRAINMENT (FOR CONCRETE REQUIRING ENTRAINED AIR).
12. STATISTICAL ANALYSIS OF LABORATORY STRENGTH TEST DATA IN ACCORDANCE WITH "STANDARD
DEVIATION" DETERMINATION OUTLINED IN ACI 318.
SHOP DRAWING SUBMITTALS
THE CONTRACTOR SHALL PREPARE DETAILED SHOP DRAWINGS TO ENABLE HIM TO
FABRICATE, ERECT AND CONSTRUCT ALL PARTS OF THE WORK IN ACCORDANCE
WITH THE DRAWINGS AND SPECIFICATIONS. THESE SHOP DRAWINGS WILL BE
REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGN INTENT ONLY. THE
CONTRACTOR IS RESPONSIBLE FOR ALL DIMENSIONS, ACCURACY AND FIT OF WORK.
ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTOR PRIOR TO
SUBMITTAL TO THE STRUCTURAL ENGINEER. DRAWINGS SUBMITTED WITHOUT
CONTRACTOR'S REVIEW WILL BE RETURNED UNCHECKED.
SUBMIT ELECTRONIC VERSIONS OF SHOP DRAWINGS. SUBMIT SHOP DRAWINGS IN
PDF FORMAT.
SUBMIT SHOP DRAWINGS FOR EACH OF THE FOLLOWING ITEMS:
1. CONCRETE REINFORCEMENT
2. CONCRETE MASONRY REINFORCEMENT
3. STRUCTURAL STEEL (INCLUDING DESIGN CALCULATIONS SEALED BY A PROFESSIONAL ENGINEER REGISTERED
IN THE STATE WHERE THE PROJECT IS CONSTRUCTED FOR ALL CONNECTIONS NOT SPECIFICALLY DETAILED
ON THE DRAWINGS)
4. STEEL DECK
5. PRECAST CONCRETE COMPONENTS (PRECAST LINTELS, ARCHITECTURAL PRECAST)
6. WOOD TRUSSES, WALLS AND HEADERS (INCLUDING DESIGN CALCULATIONS AND DETAILS SEALED BY A
PROFESSIONAL ENGINEER IN THE STATE WHERE THE PROJECT IS CONSTRUCTED).
PRODUCT DATA SUBMITTALS
THE CONTRACTOR SHALL SUBMIT FOR APPROVAL PRODUCT DATA FOR THE SPECIFIC
ITEMS LISTED BELOW. CONTRACTOR SHALL NOT USE PRODUCTS OTHER THAN THOSE
SUBMITTED WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER.
MANUFACTURER'S TRADE NAMES AND NUMBERS USED HEREIN ARE ONLY TO IDENTIFY
COLORS, FINISHES, TEXTURES, AND PATTERNS AS A BASIS OF DESIGN. PRODUCTS OF
AUTHORIZED EQUAL MANUFACTURER'S EQUIVALENT TO COLORS, FINISHES, TEXTURES,
AND PATTERNS OF MANUFACTURERS LISTED THAT MEET REQUIREMENTS OF TECHNICAL
SPECIFICATIONS IN EVERY RESPECT MAY BE ACCEPTABLE WITH SUBMITTAL OF A
COMPLETED SUBSTITUTION REQUEST CONTAINING ALL PRODUCT DATA, TESTING AND
ACTUAL SAMPLES, AND UPON APPROVAL IN WRITING BY CONTRACTING OFFICER.
SUBMIT HARD COPIES OR ELECTRONIC VERSIONS OF PRODUCT DATA. FOR HARD
COPY OPTION, SUBMIT A MINIMUM OF TWO COPIES OF PRODUCT DATA TO THE
STRUCTURAL ENGINEER FOR REVIEW (ONE COPY SHALL BE RETAINED BY THE
STRUCTURAL ENGINEER). FOR ELECTRONIC OPTION, SUBMIT PRODUCT DATA IN
ADOBE PDF FORMAT.
1. FIBER REINFORCEMENT FOR CONCRETE
2. DIAMOND PLATE DOWELS FOR SLABS ON GRADE
3. CONCRETE CURING COMPOUND
4. CONCRETE JOINT SEALANT
5. WATER STOPS
6. MASONRY JOINT REINFORCEMENT
7. EXPANSION ANCHORS
8. ADHESIVE ANCHORS
9. NON-SHRINK GROUT
10. WOOD CONNECTORS
FOUNDATIONS
FOUNDATION EXCAVATIONS AND SOIL RELATED WORK SHALL BE PERFORMED IN
ACCORDANCE WITH THE GEOTECHNICAL REPORT NUMBER 170GC00110
PREPARED BY CARDNO ATC DATED APRIL 30, 2015.
FOUNDATIONS HAVE BEEN DESIGNED BASED ON ASSUMED ALLOWABLE CAPACITIES
INDICATED BELOW. CONTRACTOR SHALL ENGAGE A LICENSED
GEOTECHNICAL ENGINEER TO REVIEW THE SOIL CONDITIONS AT THE SITE AS
NECESSARY TO CONFIRM THE ALLOWABLE CAPACITIES PRIOR TO
PLACEMENT OF THE FOUNDATIONS. CONFIRMATION OF THE ACCEPTABILITY OF THE
SOILS SHALL BE REPORTED IN WRITING TO THE STRUCTURAL ENGINEER.
IF ACTUAL ALLOWABLE CAPACITIES ARE FOUND TO BE LESS THAN THE ASSUMED
VALUES, THE CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER IMMEDIATELY
AND SHALL NOT PROCEED WITH FOUNDATION CONSTRUCTION WITHOUT REVIEW BY
THE STRUCTURAL ENGINEER.
DESIGN ALLOWABLE BEARING CAPACITIES:
SPREAD FOOTINGS: 2000 PSF
CONTINUOUS WALL FOOTINGS: 2000 PSF
FOUNDATIONS AND SOILS RELATED WORK SHALL BE INSPECTED BY A LICENSED
GEOTECHNICAL ENGINEER. WRITTEN FIELD REPORTS SHALL BE FORWARDED TO THE
STRUCTURAL ENGINEER AS SOON AS THEY BECOME AVAILABLE.
FOUNDATION CONDITIONS NOTED DURING CONSTRUCTION, WHICH DIFFER FROM
THOSE DESCRIBED IN THE GEOTECHNICAL REPORT, SHALL BE REPORTED TO THE
STRUCTURAL ENGINEER AND GEOTECHNICAL ENGINEER BEFORE FURTHER
CONSTRUCTION IS ATTEMPTED.
EXCAVATIONS FOR SPREAD FOOTINGS, COMBINED FOOTINGS, CONTINUOUS
FOOTINGS AND MAT FOUNDATIONS SHALL BE CLEANED AND HAND TAMPED TO
UNIFORM SURFACE AND SHALL BE PROTECTED AND MAINTAINED UNIFORM UNTIL
CONCRETE IS PLACED.
BELOW-GRADE WALLS
DO NOT BACKFILL AGAINST BELOW-GRADE CONCRETE (OR MASONRY) WALLS UNTIL THE CONCRETE
(OR MASONRY ASSEMBLAGE) HAS REACHED ITS 28-DAY COMPRESSIVE STRENGTH.
WHERE BACKFILL IS REQUIRED ON BOTH SIDES OF BELOW-GRADE WALLS, BACKFILL
EVENLY ON EACH SIDE OF EACH WALL TO PREVENT UNBALANCED SOIL LOADS
AGAINST THE WALL.
UNLESS NOTED OTHERWISE, DO NOT BACKFILL AGAINST BASEMENT WALLS UNTIL THE BASEMENT AND
GROUND FLOOR SLABS HAVE BEEN COMPLETELY INSTALLED AND REACHED THEIR 28-DAY
COMPRESSIVE STRENGTH AND ALL FLOOR FRAMING AND SLAB CONNECTIONS TO THE BASEMENT
WALLS HAVE BEEN COMPLETELY INSTALLED.
WHERE BASEMENT WALLS OCCUR, BACKFILL EVENLY ON ALL SIDES OF THE BUILDING TO PREVENT
UNBALANCED SOIL LOADS AGAINST THE BASEMENT STRUCTURE, UNLESS NOTED OTHERWISE.
CONCRETE
REINFORCED CONCRETE HAS BEEN DESIGNED IN ACCORDANCE WITH THE BUILDING
CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318) AND COMMENTARY
(ACI 318R).
MIXING, TRANSPORTING, AND PLACING OF CONCRETE SHALL CONFORM TO THE
LATEST EDITION OF THE SPECIFICATIONS FOR STRUCTURAL CONCRETE (ACI 301).
READY-MIXED CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ASTM C94.
IN CASE OF A DISCREPANCY, THE PLANS AND SPECIFICATIONS SHALL GOVERN.
CEMENT SHALL CONFORM TO ASTM C150, TYPE I, UNO.
FLY ASH SHALL CONFORM TO ASTM C618, CLASS C OR F. THE RATIO OF THE AMOUNT
(BY WEIGHT) OF FLY ASH TO TOTAL CEMENTITIOUS MATERIALS IN THE MIX SHALL NOT
EXCEED 25 PERCENT.
NORMAL WEIGHT AGGREGATES SHALL CONFORM TO ASTM C33.
WATER-REDUCING ADMIXTURES SHALL CONFORM TO ASTM C494.
AIR-ENTRAINING ADMIXTURES SHALL CONFORM TO ASTM C260 AND SHALL BE
CERTIFIED BY THE MANUFACTURER TO BE COMPATIBLE WITH OTHER ADMIXTURES.
CALCIUM CHLORIDE ADMIXTURES OR ADMIXTURES CONTAINING MORE THAN
0.1 PERCENT CHLORIDE IONS SHALL NOT BE USED.
IN COLD WEATHER CONDITIONS, MIXING, PLACING, FINISHING, CURING AND
PROTECTION OF CONCRETE SHALL BE PERFORMED IN ACCORDANCE WITH THE
LATEST EDITION OF ACI 306R, COLD WEATHER CONCRETING.
IN HOT WEATHER CONDITIONS, MIXING, PLACING, FINISHING, CURING AND
PROTECTION OF CONCRETE SHALL BE PERFORMED IN ACCORDANCE WITH THE
LATEST EDITION OF ACI 305R, HOT WEATHER CONCRETING.
USE OF CONSTRUCTION JOINTS AT LOCATIONS OTHER THAN THOSE INDICATED ON
THE DRAWINGS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW.
SLUMP FOR PUMPED CONCRETE SHALL BE MEASURED AT POINT OF DISCHARGE.
CONCRETE SLABS ON GRADE
SLABS ON GRADE SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE LATEST
EDITION OF THE GUIDE FOR CONCRETE FLOOR AND SLAB CONSTRUCTION (ACI 302.1R).
PLACE CONCRETE IN A MANNER SO AS TO PREVENT SEGREGATION OF THE MIX. DELAY FLOATING
AND TROWELING OPERATIONS UNTIL THE CONCRETE HAS LOST SURFACE WATER SHEEN OR ALL
FREE WATER. DO NOT SPRINKLE FREE CEMENT ON THE SLAB SURFACE.
PROVIDE CURING OF CONCRETE SLABS IMMEDIATELY AFTER FINISHING USING A
SPRAYED ON DISSIPATING-RESIN LIQUID CURING COMPOUND CONFORMING TO
ASTM C309, UNLESS NOTED OTHERWISE. ALL SCUFFS OR ABRASIONS TO THE CURING
MEMBRANE SHALL BE RECOATED DAILY. OTHER CURING METHODS MAY BE USED
WITH APPROVAL BY THE STRUCTURAL ENGINEER.
SLABS ON GRADE SHALL BE PLACED TO ACHIEVE THE FOLLOWING
MINIMUM TOLERANCES:
OVERALL VALUES: FF = 25
LOCAL VALUES: FF = 20
THE MINIMUM LOCAL AREA SHALL BE DEFINED AS 20'-0" x 20'-0".
UNLESS SHOWN OR NOTED OTHERWISE, PROVIDE CONTROL OR CONSTRUCTION
JOINTS IN SLABS-ON-GRADE AT A MAXIMUM SPACING OF 36 TIMES THE SLAB
THICKNESS. PROVIDE JOINTS AT ALL COLUMN LOCATIONS. LOCATE JOINTS TO
ELIMINATE RE-ENTRANT CORNERS AND TO CREATE SQUARE OR RECTANGULAR
SECTIONS WITH MAXIMUM LONG SIDE TO SHORT SIDE RATIO OF 1.5 TO 1.
CONTROL JOINTS IN SLABS ON GRADE SHALL NOT RECEIVE JOINT FILLER MATERIAL
UNLESS NOTED OTHERWISE.
REINFORCING STEEL
REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615 AND
SHALL HAVE A MINIMUM YIELD STRENGTH OF 60,000 PSI.
REINFORCING BAR DETAILING, FABRICATING, AND PLACING SHALL CONFORM TO THE
LATEST EDITION OF THE FOLLOWING STANDARDS: ACI 301, ACI 315, ACI 318 AND
ACI DETAILING MANUAL (SP66).
UNLESS A GREATER AMOUNT OF COVER IS INDICATED ON THE DRAWINGS, PROVIDE
THE FOLLOWING MINIMUM CONCRETE COVER OVER REINFORCEMENT AS FOLLOWS:
CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3 INCHES
#6 BARS AND LARGER EXPOSED TO EARTH OR WEATHER: 2 INCHES
#5 BARS AND SMALLER EXPOSED TO EARTH OR WEATHER: 1-1/2 INCHES
BEAM AND COLUMN TIES, STIRRUPS AND SPIRALS: 1-1/2 INCHES
ELEVATED SLAB BARS NOT EXPOSED TO EARTH OR WEATHER: 3/4 INCH
REINFORCING STEEL SHALL NOT BE TACK WELDED, WELDED, HEATED OR CUT
UNLESS INDICATED ON THE CONTRACT DOCUMENTS OR APPROVED BY THE
STRUCTURAL ENGINEER.
WHERE LAP SPLICE LENGTHS ARE NOT SHOWN OR NOTED, PROVIDE A CLASS "B" LAP.
ALL 90 DEGREE AND 180 DEGREE BENDS SHOWN ON THE DRAWINGS SHALL BE
STANDARD HOOKS, UNLESS NOTED OTHERWISE.
PROVIDE CORNER BARS OF SAME SIZE AND SPACING AS HORIZONTAL BARS AT
CORNERS OF ALL WALLS AND GRADE BEAMS. LAP SPLICE CORNER BARS WITH
STRAIGHT BARS.
UNLESS OTHERWISE SHOWN OR NOTED, PROVIDE 2-#5 BARS (ONE EACH FACE)
AROUND UNFRAMED OPENINGS IN CONCRETE WALLS AND GRADE BEAMS. PLACE
BARS PARALLEL TO THE SIDES OF THE OPENING AND EXTEND 24" BEYOND CORNERS.
FIBER REINFORCEMENT
FIBER REINFORCEMENT SHALL BE 3/4" LONG, VIRGIN (NON-RECYCLED) NYLON OR
POLYPROPYLENE FIBERS, INTRODUCED INTO THE CONCRETE MIX AT THE BATCH
PLANT, IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. DOSAGE
SHALL BE 1.5 POUNDS PER CUBIC YARD OF CONCRETE.
CONCRETE TESTING
MAKE ONE SET OF TEST CYLINDERS IN ACCORDANCE WITH ASTM C31 FOR EACH
DAY'S POUR AND FOR EACH 100 CUBIC YARDS. EACH SET SHALL INCLUDE ONE
SPECIMEN TESTED AT 7 DAYS, 2 SPECIMENS TESTED AT 28 DAYS AND ONE SPECIMEN
RETAINED IN RESERVE TO BE TESTED AT THE DIRECTION OF THE STRUCTURAL
ENGINEER. SPARE CYLINDER MAY BE DISCARDED 90 DAYS AFTER CASTING UNLESS
DIRECTED OTHERWISE BY THE STRUCTURAL ENGINEER. THIS SET OF TEST
CYLINDERS SHALL BE PROTECTED AGAINST FREEZING.
WHEN THE AMBIENT TEMPERATURE IS EXPECTED TO FALL BELOW 40 DEGREES
DURING THE COURSE OF A CONCRETE POUR OR SUBSEQUENT CURING PROCESS, AN
ADDITIONAL SET OF CONCRETE TEST CYLINDERS SHALL BE MADE AND TESTED.
THESE CYLINDERS SHALL BE STORED IMMEDIATELY ADJACENT TO, AND CURED
UNDER THE SAME CONDITIONS AS THE BUILDING CONCRETE. SPECIAL CURING BOXES
ARE NOT PERMITTED FOR THESE TEST CYLINDERS.
FORWARD COPIES OF TEST RESULTS TO THE ARCHITECT, STRUCTURAL ENGINEER,
READY-MIX SUPPLIER, CONTRACTOR AND COR WITHIN 24 HOURS AFTER TESTING.
MASONRY
CONCRETE MASONRY HAS BEEN DESIGNED IN ACCORDANCE WITH THE LATEST
EDITION OF THE BUILDING CODE REQUIREMENTS FOR CONCRETE MASONRY
STRUCTURES (ACI 530).
CONCRETE MASONRY SHALL CONSIST OF HOLLOW UNITS CONFORMING TO THE
REQUIREMENTS OF ASTM C90, WITH A MINIMUM NET AREA COMPRESSIVE STRENGTH
OF 1900 PSI. CONCRETE MASONRY ASSEMBLAGES SHALL HAVE A MINIMUM
COMPRESSIVE STRENGTH (F'M) OF 1,500 PSI AT 28 DAYS.
MORTAR SHALL BE TYPE S PROPORTIONED IN ACCORDANCE WITH ASTM C270.
GROUT FOR REINFORCED MASONRY SHALL BE PROPORTIONED IN ACCORDANCE WITH
ASTM C476. COARSE AND FINE AGGREGATES SHALL CONFORM TO ASTM C404. USE
COARSE GROUT FOR ALL GROUTING EXCEPT HIGH-LIFT POURS DEFINED BY ACI 530-05
TABLE 1.16.1, WHERE FINE GROUT SHALL BE USED.
PROVIDE 9-GAUGE GALVANIZED STEEL WIRE JOINT REINFORCEMENT IN ALL MASONRY
CONSTRUCTION. REINFORCEMENT SHALL BE CONTINUOUS AND BE LAPPED EIGHT
INCHES AT SPLICES. CUT REINFORCEMENT AT ALL CONTROL AND EXPANSION JOINTS.
SPACE REINFORCEMENT AT 8" ON CENTER FOR PARAPETS AND BELOW GROUND
FLOOR ELEVATION. ELSEWHERE SPACE REINFORCEMENT AT 16 INCHES ON CENTER.
BEAMS AND LINTELS SHALL BEAR A MINIMUM OF 8 INCHES ONTO SUPPORTING
MASONRY, UNLESS NOTED OTHERWISE. BEARING FOR ALL BEAMS, LINTELS AND
JOISTS SHALL BE GROUTED SOLID A MINIMUM OF ONE COURSE (8 INCHES)
BELOW BEARING ELEVATION, UNLESS NOTED OTHERWISE.
EXPANSION ANCHORS
EXPANSION ANCHORS SHALL BE CARBON STEEL ANCHORS AS MANUFACTURED BY
HILTI FASTENING SYSTEMS OR AN EQUIVALENT SUBSTITUTE APPROVED BY THE
STRUCTURAL ENGINEER AND SHALL BE INSTALLED IN CONFORMANCE WITH THE
MANUFACTURER'S RECOMMENDATIONS.
EXPANSION ANCHORS SHALL NOT BE INSTALLED IN CONCRETE UNTIL IT HAS
ATTAINED ITS SPECIFIED MINIMUM 28 DAY COMPRESSIVE STRENGTH.
ADHESIVE ANCHORS
ADHESIVE ANCHORS SHALL BE HILTI "HIT HY200" FOR SOLID SUBSTRATE AND HILTI
"HIT HY70" FOR HOLLOW SUBSTRATE OR AN EQUIVALENT SUBSTITUTE APPROVED
BY THE STRUCTURAL ENGINEER, UNLESS NOTED OTHERWISE ON PLANS. ANCHORS
SHALL BE INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S
RECOMMENDATIONS BY INSTALLERS TRAINED BY THE MANUFACTURER'S
REPRESENTATIVE.
MINIMUM EMBEDMENT DEPTH SHALL BE 8 BOLT DIAMETERS UNLESS NOTED
OTHERWISE.
NON-SHRINK GROUT
GROUT SHALL BE A NON-METALLIC, SHRINKAGE RESISTANT (WHEN TESTED IN
ACCORDANCE WITH THE LATEST EDITION OF ASTM C827 OR CRD-C621), PREMIXED,
NON-CORROSIVE, NON-STAINING PRODUCT CONTAINING PORTLAND CEMENT, SILICA
SANDS, SHRINKAGE COMPENSATING AGENTS AND FLUIDITY IMPROVING COMPOUNDS.
GROUT SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (F'C) OF 5,000 PSI IN
28 DAYS.
WATERSTOPS
SELF-EXPANDING STRIP WATER STOPS SHALL BE VOLCLAY WATERSTOP-RX 101 UNLESS NOTED
OTHERWISE. INSTALL IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
PVC WATERSTOPS
PROVIDE FACTORY MADE WATERSTOP FABRICATIONS FOR ALL CHANGES OF
DIRECTION, INTERSECTIONS, AND TRANSITIONS LEAVING ONLY STRAIGHT BUTT JOINT
SPLICES FOR THE FIELD.
PROVIDE HOG RINGS OR GROMMETS SPACED AT 12 INCHES ON CENTER ALONG
LENGTH OF WATERSTOP.
PROVIDE TEFLON COATED THERMOSTATICALLY CONTROLLED WATERSTOP SPLICING
IRONS FOR FIELD BUTT SPLICES.
FIELD BUTT SPLICES SHALL BE HEAT FUSED WELDED USING A TEFLON COATED
THERMOSTATICALLY CONTROLLED WATERSTOP SPLICING IRON AT APPROXIMATELY
380 DEGREES F. FOLLOW APPROVED MANUFACTURER RECOMMENDATIONS.
LAPPING OF WATERSTOP, USE OF ADHESIVES, OR SOLVENTS SHALL NOT BE ALLOWED.
CENTER WATERSTOP IN JOINT AND SECURE WATERSTOP IN CORRECT POSITION
USING HOG RINGS OR GROMMETS SPACED AT 12 INCHES ON CENTER ALONG THE
LENGTH OF THE WATERSTOP AND WIRE TIE TO ADJACENT REINFORCING STEEL.
MASTIC COATING
MASTIC COATING FOR PROTECTION OF INDICATED ITEMS SHALL BE BITUMASTIC 50
COAL TAR MASTIC BY CARBOLINE OR EQUIVALENT SUBSTITUTE APPROVED BY THE
STRUCTURAL ENGINEER. INSTALL AT LOCATIONS INDICATED ON DRAWINGS.
UNLESS NOTED OTHERWISE, APPLY MASTIC TO A COATING THICKNESS OF 18 MILS.
PROVIDE FULL COVERAGE OVER ITEMS INDICATED TO RECEIVE COATING.
STRUCTURAL STEEL
STRUCTURAL STEEL DETAILING, FABRICATION AND ERECTION SHALL CONFORM TO
THE ANSI/AISC 360 SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, LATEST
EDITION WITH AMENDMENTS, AND THE AISC 303 CODE OF STANDARD PRACTICE FOR
STEEL BUILDINGS AND BRIDGES, LATEST EDITION WITH AMENDMENTS.
STRUCTURAL STEEL WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992, 50 KSI.
STRUCTURAL STEEL PLATES AND ROLLED SHAPES OTHER THAN WIDE-FLANGE
SHAPES SHALL CONFORM TO ASTM A36, UNLESS NOTED OTHERWISE.
STRUCTURAL STEEL TUBING SHALL CONFORM TO ASTM A500, GRADE B.
STRUCTURAL PIPE SHALL CONFORM TO ASTM A53, GRADE B.
ANCHOR RODS SHALL CONFORM TO ASTM F1554, GRADE 36, UNLESS NOTED
OTHERWISE.
STEEL STUDS SHALL CONFORM TO ASTM A108.
BOLTED CONNECTIONS SHALL CONFORM TO THE SPECIFICATION FOR STRUCTURAL
JOINTS USING ASTM A325 OR A490 BOLTS, APPROVED BY THE RESEARCH COUNCIL
ON STRUCTURAL CONNECTIONS OF THE ENGINEERING FOUNDATION. BOLTED
CONNECTIONS FOR STRUCTURAL STEEL MEMBERS SHALL BE MADE WITH 3/4"
DIAMETER A325 BOLTS, UNLESS NOTED OTHERWISE. BOLTED CONNECTIONS SHALL BE
TIGHTENED TO THE SNUG TIGHT CONDITION, EXCEPT BOLTED CONNECTIONS IN
BRACE ELEMENTS ARE TO BE FULLY PRETENSIONED WITH CLASS A FAYING SURFACES.
WELDING PROCEDURES SHALL CONFORM TO THE LATEST EDITION OF THE AMERICAN
WELDING SOCIETY'S STRUCTURAL WELDING CODE FOR STEEL ANSI/AWS D1.1.
WELDED CONNECTIONS USING ASTM A992 STEEL AS A BASE METAL SHALL BE MADE
WITH E70XX LOW HYDROGEN ELECTRODES. UNLESS OTHERWISE SHOWN OR NOTED
ON THE DRAWINGS, OTHER WELDED CONNECTIONS MAY BE MADE WITH STANDARD
E70XX ELECTRODES.
STRUCTURAL STEEL THAT RECEIVES FINISH PAINT SHALL BE SHOP-PRIMED WITH A
RUST-INHIBITING PRIMER, UNLESS NOTED OTHERWISE ON THE DRAWINGS.
CONTRACTOR SHALL VERIFY PRIMER IS COMPATIBLE WITH FINISH COAT SYSTEM
SPECIFIED BY THE ARCHITECT. COORDINATE FINISH PAINTING REQUIREMENTS
WITH THE ARCHITECT.
STRUCTURAL STEEL THAT IS NOT EXPOSED IN THE FINISHED CONSTRUCTION AND
DOES NOT RECEIVE FINISH PAINT SHALL NOT BE SHOP-PRIMED, UNLESS NOTED
OTHERWISE ON THE DRAWINGS.
STRUCTURAL STEEL NOTED TO BE GALVANIZED SHALL BE HOT-DIP GALVANIZED IN
CONFORMANCE WITH ASTM A123.
DO NOT PAINT OR GALVANIZE THE FOLLOWING SURFACES:
1. SURFACES TO BE WELDED.
2. SURFACES TO RECEIVE BOLTED SLIP-CRITICAL CONNECTIONS.
3. SURFACES TO RECEIVE SHEAR STUD CONNECTIONS.
4. SURFACES TO RECEIVE SPRAYED-ON FIREPROOFING.
ALL ABRASIONS TO GALVANIZED SURFACES OR SURFACES TO RECEIVE AN
ARCHITECTURAL FINISH COAT SHALL BE TOUCHED-UP AFTER ERECTION IS COMPLETE.
FOR PAINTED STEEL, USE A PRIMER EQUIVALENT TO THE SHOP PAINT.
FOR GALVANIZED STEEL, USE A ZINC-RICH COLD-GALVANIZING PAINT.
DESIGN CONNECTIONS NOT SHOWN IN ACCORDANCE WITH THE ASD SPECIFICATION
AND MANUAL OF STEEL CONSTRUCTION. UNLESS NOTED OTHERWISE ON THE
DRAWINGS, DESIGN BEAM CONNECTIONS NOT SHOWN, TO SUPPORT A MINIMUM OF A
10 KIP SHEAR REACTION. PROVIDE NO LESS THAN 2 BOLTS IN ANY SINGLE LINE OF
BOLTS, UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS.
PROVIDE L4X4X1/4 FRAMED OPENINGS FOR ALL ROOF PENETRATIONS 12 INCHES OR
LARGER ALONG ANY SIDE, UNLESS LARGER FRAMING IS INDICATED. REFER TO
MECHANICAL AND PLUMBING DRAWINGS FOR PENETRATIONS. COORDINATE FRAMED
OPENING SIZES AND LOCATIONS WITH THE MECHANICAL AND PLUMBING
CONTRACTORS.
DESIGN DATA
THE BUILDING STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE
2012 INTERNATIONAL BUILDING CODE.
SEE LOAD MAPS FOR FLOOR LOADING CRITERIA.
SNOW LOAD DESIGN DATA
1. GROUND SNOW LOAD (PG) = 20 PSF
2. FLAT ROOF SNOW LOAD (PF) = 13 PSF
3. SNOW EXPOSURE FACTOR (CE) = 0.9
4. THERMAL FACTOR (CT) = 1
5. SNOW LOAD IMPORTANCE FACTOR (IS) = 1.0
WIND LOAD DESIGN DATA
1. BASIC WIND SPEED (3-SECOND GUST) = 115 MPH
2. WIND LOAD IMPORTANCE FACTOR (IW) = 1.0
3. WIND EXPOSURE = B
4. WIND DESIGN PRESSURE (P) = VARIES WITH HEIGHT AND LOCATION
EARTHQUAKE DESIGN DATA
1. SHORT PERIOD SPECTRAL RESPONSE (SS) = 0.178
2. 1-SECOND SPECTRAL RESPONSE (S1) = 0.092
3. SEISMIC IMPORTANCE FACTOR (IE) = 1.0
4. OCCUPANCY CATEGORY = II
5. SEISMIC DESIGN CATEGORY = B
6. SITE CLASSIFICATION = D
7. SHORT PERIOD SPECTRAL RESPONSE COEFFICIENT (SDS) = 0.190
8. 1-SECOND SPECTRAL RESPONSE COEFFICIENT (SD1) = 0.147
9. BASIC STRUCTURAL SYSTEM / SEISMIC RESISTING SYSTEM: A15 - LIGHT-FRAME (WOOD) WALLS
SHEATHED WITH WOOD STRUCTURAL PANELS RATED FOR SHEAR RESISTANCE
10. ANALYSIS PROCEDURE UTILIZED = EQUIVALENT LATERAL FORCE PROCEDURE
11. RESPONSE MODIFICATION COEFFICIENT (R) = 6.5
12. SEISMIC RESPONSE COEFFICIENT (CS) = 0.029
NORMAL WEIGHT CONCRETE SHALL BE USED IN THE FOLLOWING AREAS AND SHALL
HAVE THE PROPERTIES AS SHOWN BELOW:
FOUNDATIONS
1. COMPRESSIVE STRENGTH (28 DAYS): 4000 PSI
2. MAXIMUM SLUMP: 4 INCHES
3. MINIMUM CEMENTITIOUS MATERIALS CONTENT: 470 LB./CU. YD. (USE TYPE II SULFATE
RESISTANT CEMENT)
4. MAXIMUM SLUMP FOR CONCRETE CONTAINING HIGH-RANGE WATER-REDUCING ADMIXTURE: 8
INCHES (AFTER ADMIXTURE IS ADDED TO CONCRETE WITH 2 TO 4 INCH SLUMP).
5. MAXIMUM WATER/CEMENTITIOUS MATERIALS RATIO: 0.48
6. MAXIMUM COARSE AGGREGATE SIZE: 1 1/2 INCHES
7. AIR CONTENT: N/A
FOUNDATION WALLS
1. COMPRESSIVE STRENGTH (28 DAYS): 4000 PSI
2. MAXIMUM SLUMP: 4 INCHES
3. MINIMUM CEMENTITIOUS MATERIALS CONTENT: 470 LB./CU. YD. (USE TYPE II SULFATE
RESISTANT CEMENT)
4. MAXIMUM SLUMP FOR CONCRETE CONTAINING HIGH-RANGE WATER-REDUCING ADMIXTURE: 8
INCHES (AFTER ADMIXTURE IS ADDED TO CONCRETE WITH 2 TO 4 INCH SLUMP).
5. MAXIMUM WATER/CEMENTITIOUS MATERIALS RATIO: 0.48
6. MAXIMUM COARSE AGGREGATE SIZE: 1 INCH
7. AIR CONTENT: N/A
RETAINING WALLS AND CURBS/SIDEWALKS/SLABS EXPOSED TO DE-ICERS
1. COMPRESSIVE STRENGTH (28 DAYS): 4000 PSI
2. MAXIMUM SLUMP: 4 INCHES
3. MINIMUM CEMENTITIOUS MATERIALS CONTENT: 517 LB./CU. YD. (USE TYPE II SULFATE
RESISTANT CEMENT)
4. MAXIMUM SLUMP FOR CONCRETE CONTAINING HIGH-RANGE WATER-REDUCING ADMIXTURE: 8
INCHES (AFTER ADMIXTURE IS ADDED TO CONCRETE WITH 2 TO 4 INCH SLUMP).
5. MAXIMUM WATER/CEMENTITIOUS MATERIALS RATIO: 0.45
6. MAXIMUM COARSE AGGREGATE SIZE: 1 INCH
7. AIR CONTENT: 6.0% +/- 1%
SLABS ON GRADE
1. COMPRESSIVE STRENGTH (28 DAYS): 4000 PSI
2. MAXIMUM SLUMP: 4 INCHES
3. MINIMUM CEMENTITIOUS MATERIALS CONTENT: 470 LB./CU. YD. (USE TYPE II SULFATE
RESISTANT CEMENT)
4. MAXIMUM SLUMP FOR CONCRETE CONTAINING HIGH-RANGE WATER-REDUCING ADMIXTURE: 8
INCHES (AFTER ADMIXTURE IS ADDED TO CONCRETE WITH 2 TO 4 INCH SLUMP).
5. MAXIMUM WATER/CEMENTITIOUS MATERIALS RATIO: 0.48
6. MAXIMUM COARSE AGGREGATE SIZE: 1 INCH
7. AIR CONTENT: 6% +/- 1%
8. HIGH RANGE WATER REDUCING ADMIXTURE AND FIBER REINFORCING REQUIRED.
TRUSSES
MATERIALS:
1. USE LUMBER AS REQUIRED BY THE TRUSS MANUFACTURER; MINIMUM GRADE IS TO BE SYP NO. 2, KD
15% MC.
2. LUMBER SHALL ALSO BE FIRE-RETARDANT-TREATED.
3. CONNECTIONS: ALL CONNECTIONS ARE TO BE DESIGNED BY THE TRUSS MANUFACTURER FOR THE
LOADS SHOWN ON THE DRAWINGS. CONNECTOR SHALL BE DEFORMED-PLATE TYPE OF MINIMUM 20- GAUGE GALVANIZED STEEL SHEET. ALL JOINTS ARE TO BE DESIGNED USING METHODS AS SET FORTH
IN THE LATEST REVISION OF TPI STANDARDS.
SPECIFICATIONS: UNLESS SPECIFICALLY SHOWN OTHERWISE, DESIGN, FABRICATION, ERECTION, HANDLING, AND BRACING REQUIREMENTS ARE TO BE GOVERNED BY THE LATEST REVISIONS OF:
1. NATIONAL DESIGN SPECIFICATIONS FOR STRESS-GRADE LUMBER AND ITS FASTENINGS.
2. TIMBER CONSTRUCTION STANDARDS.
3. DESIGN SPECIFICATIONS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES.
4. TRUSS PLATE INSTITUTE PUBLICATIONS-BTW BRACING WOOD TRUSSES: COMMENTARY AND
RECOMMENDATIONS.
DESIGN:
1. ALL TRUSSES ARE TO BE DESIGNED BY THE TRUSS MANUFACTURER FOR THE GIVEN LOADS. TRUSS
DESIGNS ARE TO BE SUBMITTED FOR APPROVAL PRIOR TO FABRICATION AND MUST BE STAMPED WITH
THE SEAL OF A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF ILLINOIS.
2. DESIGN LOADS:
TOP CHORD:
LIVE LOAD: 30 PSF
DEAD LOAD: 15 PSF
BOTTOM CHORD:
DEAD LOAD: 10 PSF
LIVE LOAD: 20 PSF AT WALKWAYS ONLY
WOOD FRAMING
SPECIFICATIONS AND STANDARDS:
1. DESIGN AND DETAILING OF CONNECTIONS SHALL CONFORM TO THE NATIONAL DESIGN SPECIFICATION
FOR WOOD CONSTRUCTION (1991 EDITION) RECOMMENDED PRACTICE BY NATIONAL FOREST
PRODUCTS ASSOCIATION.
MATERIALS:
1. USE ONLY STRESS-GRADE LUMBER AND SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES FOR ALL
DIMENSIONAL LUMBER FRAMING (SPRUCE-PINE-FIR NUMBER 1/2).
2. MODULES OF ELASTICITY (E) = 1,400,000 PSI FOR ALL MEMBERS.
3. ALLOWABLE BENDING STRESS (FB) = 875 PSI FOR ALL MEMBERS.
4. ALLOWABLE SHEAR STRESS (FV) = 135 PSI FOR ALL MEMBERS.
5. CONNECTION PLATES: ASTM A-36.
6. BOLTS: ASTM A-307 WITH 2 WASHERS.
7. LIGHT-GAUGE JOIST HANGERS AND FRAMING ANCHORS: 16-OR 18_GAUGE GALVANIZED STEEL SIZED
FOR FULL LOAD-CARRYING CAPACITY OF SUPPORTED MEMBER. NOMENCLATURE BASED ON ANCHORS
MANUFACTURED BY SIMPSON STRONG-TIE COMPANY, INC.
8. USE ONLY PLYWOOD OR ORIENTED STRAND BOARD (OSB) WITH THICKNESS AND PANEL INDEX AS
INDICATED ON DRAWINGS. ALL SHEATHING IS TO HAVE EXTERIOR GLUE.
CONSTRUCTION REQUIREMENTS:
1. MAKE ALL CUTS TRUE AND SQUARE FOR FULL BEARING AT STRUCTURAL JOINTS.
2. BOLT HOLES AND PLATES ARE TO BE PLACED AS SHOWN ON DETAILS AND TO PROVIDE SPECIFIED
SPACINGS, END DISTANCES, AND EDGE DISTANCES.
3. PROVIDE PLYWOOD NAILINGS AS RECOMMENDED BY THE AMERICAN PLYWOOD ASSOCIATION OR AS
SHOWN ON THE STRUCTURAL PLANS.
4. CONNECT ALL FRAMING SECURELY TOGETHER WITH NAILS, SPIKES, OR FRAMING ANGLES.
LAMINATED VENEER LUMBER (LVL):
1. LAMINATED VENEER LUMBER (LVL) SHALL BE MANUFACTURED UNDER A PROCESS APPROVED BY THE
NATIONAL RESEARCH BOARD. EACH PIECE SHALL BEAR A STAMP OR STAMPS NOTING THE NAME AND
PLANT NUMBER OF THE MANUFACTURER, THE GRADE, THE NATIONAL RESEARCH BOARD NUMBER,
AND THE QUALITY CONTROL AGENCY.
2. ALL LAMINATED VENEER LUMBER SHALL BE MANUFACTURED IN ACCORDANCE WITH ICC-ES REPORT
ESR-1387
3. ALL MEMBERS SHALL BE WESTERN SPECIES, GRADE 1.8E, Fb = 2,600 PSI, Fv = 285 PSI
4. DESIGN SHOWN ON PLANS IS BASED ON LVL MEMBERS MANUFACTURED BY TRUS JOIST, A
WEYERHAEUSER BUSINESS. ALTERNATE MANUFACTURERS MAY BE USED SUBJECT TO APPROVAL.
5. ALTERNATE JOIST HANGERS AND OTHER HARDWARE MAY BE SUBSTITUTED FOR THE ITEMS SHOWN
PROVIDED THEY HAVE CURRENT ICC_ES ELVALUATION REPORTS DEMONSTRATING THAT THE
PRODUCTS HAVE EQUAL OR GREATER LOAD CAPABILITIES. ALL JOIST HANGERS AND OTHER
HARDWARE SHALL BE COMPATIBLE IN SIZE WITH THE MEMBERS PROVIDED.
TREATED WOOD:
1. ALL WOOD PLATES, LEDGERS AND BLOCKING IN DIRECT CONTACT WITH WEATHER, EARTH, CONCRETE
OR MASONRY SHALL BE PRESSURE-TREATED WITH A PRESERVATIVE PROCESS APPROVED BY
AMERICAN WOOD PRESERVERS ASSOCIATION (AWPA) STANDARD U1 FOR THE SPECIFIC USE SHOWN
ON THE PLANS.
2. ALL METAL FASTENERS IN CONTACT WITH TREATED WOOD SHALL BE HOT DIPPED GALVANIZED (PER
ASTM A 153) OR STAINLESS STEEL.
TIMBER CONNECTORS:
1. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE BY SIMPSON STRONG-TIE
COMPANY, INC. AS SPECIFIED IN THE LATEST EDITION OF THEIR CATALOG. ALTERNATIVE FASTENERS
MAY BE APPROVED SUBJECT TO SUBMITTAL OF MANUFACTURER'S INFORMATION DEMONSTRATING
EQUIVALENT LOAD CAPACITY AND FUNCTION.
2. ALL BOLTS INTO TIMBER MEMBERS SHALL BE A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS
OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD.
3. ALL NAILS SHALL BE COMMON UNLESS NOTED OTHERWISE.
WOOD AND TIMBER FRAMING NOTES:
1. TRUSS MANUFACTURER TO DESIGN TRUSSES LATERAL BRACING. TRUSS DRAWINGS TO BE STAMPED
BY A STRUCTURAL ENGINEER REGISTERED IN THE STATE OF ILLINOIS.
2. ALL 2x WOOD LOOKERS TO BACK-SPAN 2'-0" TO THE FIRST INTERIOR TRUSS.
3. TYPICAL ROOF TRUSS SPACING TO BE 2'-0" OC, UNLESS NOTED OTHERWISE.
ROUGH CARPENTRY MATERIAL NOTES.
1. EACH PIECE OF LUMBER SHALL BEAR A GRADE STAMP, INDICATING GRADES OF MATERIAL AND RULES
OR STANDARDS UNDER WHICH IT WAS PRODUCED.
2. SHEATHING: APA RATED EXPOSURE 1 OR EXTERIOR; PANEL GRADE CD OR BETTER.
3. PROVIDE CONTINUOUS SOLID BLOCKING AT MID-HEIGHT OF ALL STUD WALLS OVER 10'-0" IN HEIGHT.
4. ALL STUD WALLS, UNLESS NOTED OTHERWISE SHALL BE 2X4 @ 16" OC. FOR INTERIOR OR 2X6 @ 16" OC
FOR EXTERIOR.
5. USE FULL-LENGTH STUDS (BALLOON FRAME) ON EXTERIOR WALLS AT STAIRWAYS AND AT VAULTED
CEILINGS.
6. ALL WOOD STUD WALLS SHALL HAVE LOWER WOOD PLATE ATTACHED TO WOOD FRAMING BELOW
WITH 16d NAILS @ 6" OC STAGGERED, OR BOLTED TO CONCRETE WITH 5/8" DIAMETER x 7" EMBEDMENT
ANCHOR BOLTS @ 6'-0" OC UNLESS NOTED OTHERWISE ON PLANS.
132 & 133 eric.slaughter
30' - 5 1/8" 15' - 8 3/4" 35' - 6 1/2" 35' - 0 1/4"
/8
/2
/8
/4
4' - 0" 33' - 6 5/8" 21' - 5" 2' - 0"
3'
/2
/2
/2
7/ 8"
15' - 11 3/8" 12' - 5 1/8" 9' - 11 3/4" 28' - 9 3/4"
/2
/8
/4
/2
116' - 8 5/8"
7' - 4 3/4"
7'
3/ 4"
60' - 11 5/8"
/4
C4 C4
C4
C4
C4
C4 C4
C4 C4
C3
C4 C4
C4
C W
CW8
CW8
C W
CW8
CW8
CW8
C W
CW8
C W
CW8
C W
CW8
C W
CW8
C W
C W
CW8
CW8
C W
C W
C W
CW8
C W
CW8
C W
C W
CW8
C W
W
W6
W
W
W
W6
W
M
M6
M6
W6
W
W6
W6
W
W6
W
W
M
W6
M6
W
W6
M
M
M6
W F
WF36
WF36
W F
W F
WF36
W F
WF36
W F
W F
WF36
WF36
W F
W F
W F
WF36
W F
W F
WF36
W F
WF36WF36
W F
WF36
WF36
W F
WF36
W F
WF48
FS
FS
FS
FS
5' - 4 7/8"
2' - 11" 20' - 6 3/8" 8' - 1 3/4" 20' - 7" 5' - 7 5/8"
4' - 0"
3' - 1 1/4"
7'
/8
/2
8'
/8
/2
20' - 7 1/8"
19' - 4 7/8" 8' - 7 5/8" 29' - 2" 47' - 11 7/8"
12' - 11 1/4" 19' - 7 1/8"
8' - 8" 5' - 2 3/8"
3'
3/ 8"
THICKENED SLAB (TS), TYPICAL
AT INTERIOR BEARING WALLS
T/FTG = 98' - 0"
TYP, UNO
F4.0
12' - 8 3/8"
11' - 5 3/4"
C4 C4 C4
C4
C4
SB301
TYP
SB301
TYP 7
SB301
TYP
TYP
SB301
C4
8'
/8
TYPE A
1. GROUT SOLID ALL CELLS CONTAINING REINFORCEMENT AND BELOW GRADE.
2. PROVIDE MATCHING HOOKED DOWELS INTO FOUNDATION FOR ALL VERTICAL REINFORCEMENT.
3. PROVIDE VERT. BAR AT ALL CORNERS, INTERSECTIONS, AND ENDS OF WALL. BAR SIZE TO MATCH TYP. VERT.
REINFORCEMENT.
4. PROVIDE VERT. BARS AT JAMBS OF ALL OPENINGS.
FOR OPENINGS W/ WIDTH < 3'-4" PROVIDE VERT. BARS AT FIRST TWO CORES AT EACH JAMB.
FOR OPENINGS W/ WIDTH > 3'-4" < 8'-0" PROVIDE VERT. BARS AT FIRST THREE CORES AT EACH
JAMB.
BAR SIZE TO MATCH TYP. VERT. REINFORCEMENT.
5. PROVIDE VERT. BAR AT FIRST CORE ON EACH SIDE OF CONTROL JOINTS. BAR SIZE AND SPACING TO MATCH TYP. VERT.
REINFORCEMENT.
6. PROVIDE HORIZONTAL BOND BEAM W/ 1-#5 CONT. BELOW ALL WINDOW OPENINGS. EXTEND 2'-0" PAST
OPENING.
7. SPLICE ALL REINFORCEMENT PER TABLE THIS SHEET.
NOTES:
REINFORCEMENTCMU SIZE REMARKSMARK TYPE
CMU WALL SCHEDULE
#5 @ 32" OCAM6 6"
1/
D 1/
D
#3
MASONRY CONSTRUCTION
LAP SPLICE LENGTHS
1'-6"
#4 2'-0"
#5 2'-6"
#6 3'-0"
#7 3'-6"
#8 4'-0"
#9 4'-6"
SECTION LENGTH NOTES
CMU WALL LINTEL SCHEDULE
NOTES:
1. PROVIDE MIN 8" BEARING FOR LINTELS, UNO
BOND BEAM W/ 2 - #5 CONT BAR
SOLID GROUTED COURSES
OF BLOCK. POUR GROUT AT
SAME TIME AS BOND BEAM
H
W
3" C
LR
M
A X
6" WIDE X 16" TALL
6" WIDE X 24" TALL
8" TO 4'-0"
4'-1" TO 6'-8"
TYPE
A
A
TYPE "A"
th re e-qu ar te rs in ch o ne fo ot on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot
B th re e in ch es o ne fo ot
SCALE
PROJECT PRINCIPAL
PROJECT ARCHITECT
ELECTRICAL ENGINEER
PROJECT MANAGER
MECHANICAL ENGINEER
Use or disclosure of data contained on this sheet is subject to the restriction on the title page of this proposal.
Robinson
Robinson
Fischer
Gobreski
Daller
Danville, IL
Drawing Title
Approved:
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
B
A
C
D
E
F
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veteran Affairs
LANDSCAPE ARCHITECT
CIVIL ENGINEER
STRUCTURAL ENGINEER
Cyr
Meneley
VanderWoude
PLUMBING ENGINEER Daller
CONSTRUCTION DOCUMENTS 06/21/2017
550-316
One Indiana Square, Suite 2100 Indianapolis, IN 46204
United States P: 317 532 5400 F: 317 532 5499 www.URScorp.com
/1
/2
:1 :5
P
M C
U s e rs \b th o m a s \ D o c u m e n ts
\1 .1
V A
D a n v ill e G re e n H o m e s b th o m a s .r v t
SB101
INDEPENDENCE - FOUNDATION PLAN
WJTMAV2017.06.21
VA DANVILLE - CONSTRUCT TWO
GREEN HOMES
URS PROJECT NO. 25628010
SCALE: 1/8" = 1'-0"SB101
1 INDEPENDENCE - FOUNDATION PLANN
FOOTING SCHEDULE
MARK
FOOTING SIZE
FOOTING REINFORCEMENT REMARKS
WIDTH DEPTH
F4.0 4' - 0" 1' - 0" (4) #5 EA WAY
TS
WF36 3' - 0" 1' - 0" (3) #5 CONT
WF48 4' - 0" 2' - 0" (4) #5 CONT
GENERAL FOUNDATION NOTES
1. ALLOWABLE DESIGN BEARING PRESSURE FOR SPREAD FOOTINGS = 2000 PSF, ALLOWABLE DESIGN BEARING PRESSURE FOR CONTINUOUS WALL FOOTINGS = 2000 PSF.
CONTRACTOR TO VERIFY IN FIELD AND SHALL NOTIFY ENGINEER OF ANY EXISTING SOILS AT BEARING ELEVATION THAT ARE UNACCEPTABLE FOR FOOTING SUPPORT. ALLOWABLE FOOTING PRESSURE IS BASED ON GEOTECHNICAL REPORT NUMBER 170GC00110 PREPARED BY CARDNO ATC DATED APRIL 30, 2015.
2. WHERE FOUNDATION SUBGRADE IS INADVERTENTLY OVEREXCAVATED, OR WHERE UNSUITABLE SOILS ARE ENCOUNTERED FOR SLAB SUPPORT, REMOVE ALL DISTURBED/UNSUITABLE SOIL AND REPLACE TO PROPER GRADE WITH LEAN CONCRETE OR GRANULAR FILL (CA-6 OR EQUIVALENT) COMPACTED TO 95% OF STANDARD PROCTOR
DENSITY.
3. COORDINATE LOCATION OF ALL UTILITIES THROUGH OR UNDER FOUNDATIONS WITH MEP SHEETS.
4. COORDINATE WALL LOCATIONS WITH ARCH. DRAWINGS.
5. COORDINATE WALL OPENINGS WITH ARCH. DRAWINGS.
6. CONTRACTOR TO DESIGN ALL COLUMN BASE PLATES TO BE HIDDEN IN WALLS.
CONCRETE WALL SCHEDULE
MARK WALL THICKNESS
HORIZONTAL REINF VERTICAL REINF
REMARKSINSIDE FACE OUTSIDE FACE INSIDE FACE OUTSIDE FACE
CW8 8" #5 @ 12" OC - #5 @ 12" OC - CENTER REINF IN WALL
3' - 0" 1' - 0" (3) #5 CONT
eric.slaughter
5' - 10" 3' - 0"
SLOPED FLOOR
6' - 10 1/2" 7' - 7 1/2" 3' - 0"
SLOPED FLOOR
6' - 10 1/2" 7 1/4"
SLOPED FLOOR
6' - 10 1/2" 3' - 0" 14' - 7 3/4" 3' - 0"
SLOPED FLOOR
6' - 11 5/8" 7' - 6 3/8" 3' - 0"
SLOPED FLOOR
6' - 11 1/8"
5'
1/ 4"
/4
S
LO
P E
D F
LO
O
R
6'
1"
3'
7'
S
LO
P E
D F
LO
O
R
6'
1"
3'
/4
3'
S
LO
P E
D F
LO
O
R
6'
1"
1/
4"
S
LO
P E
D F
LO
O
R
6'
1"
3'
/8
3'
S
LO
P E
D F
LO
O
R
6'
1"
10' - 10 1/4" 5' - 2"
5'
/2
S
LO
P E
D F
LO
O
R
/8
/8
3' - 1 1/8" 3' - 0" 9' - 6 1/2"
SLOPED FLOOR
15' - 1 3/8"
SB301
14' - 10 1/4" 5' - 2"
14' - 10 1/4" 5' - 2"
TYP
CONTROL OR
CONSTRUCTION JOINT
@ 12'-0" OC (MAX) (TYP)
SB301
TYP
14' - 10 1/4" 5' - 2"
4" SLAB ON GRADE WITH
FIBER MESH REINFORCEMENT
SLAB PLAN LEGEND
AREA OF DEPRESSED SLAB, SEE DETAIL 6/SB301
SLOPED FLOOR AREA. PITCH FLOOR TO DRAIN.
SLOPE SHALL NOT EXCEED 1/8 INCH PER FOOT.
INDICATES CONTROL OR CONSTRUCTION JOINT
SEE DETAIL 1/SB301.
th re e-qu ar te rs in ch o ne fo ot on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot
B th re e in ch es o ne fo ot
SCALE
PROJECT PRINCIPAL
PROJECT ARCHITECT
ELECTRICAL ENGINEER
PROJECT MANAGER
MECHANICAL ENGINEER
Use or disclosure of data contained on this sheet is subject to the restriction on the title page of this proposal.
Robinson
Robinson
Fischer
Gobreski
Daller
Danville, IL
Drawing Title
Approved:
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
B
A
C
D
E
F
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veteran Affairs
LANDSCAPE ARCHITECT
CIVIL ENGINEER
STRUCTURAL ENGINEER
Cyr
Meneley
VanderWoude
PLUMBING ENGINEER Daller
CONSTRUCTION DOCUMENTS 06/21/2017
550-316
One Indiana Square, Suite 2100 Indianapolis, IN 46204
United States P: 317 532 5400 F: 317 532 5499 www.URScorp.com
/1
/2
:1 :5
P
M C
U s e rs \b th o m a s \ D o c u m e n ts
\1 .1
V A
D a n v ill e G re e n H o m e s b th o m a s .r v t
SB102
INDEPENDENCE - SLAB PLAN
WJTMAV2017.06.21
VA DANVILLE - CONSTRUCT TWO
GREEN HOMES
URS PROJECT NO. 25628010
SCALE: 1/8" = 1'-0"SB102
1 INDEPENDENCE - SLAB PLANN
eric.slaughter
TYPE A
1. GROUT SOLID ALL CELLS CONTAINING REINFORCEMENT AND BELOW GRADE.
2. PROVIDE MATCHING HOOKED DOWELS INTO FOUNDATION FOR ALL VERTICAL REINFORCEMENT.
3. PROVIDE VERT. BAR AT ALL CORNERS, INTERSECTIONS, AND ENDS OF WALL. BAR SIZE TO MATCH TYP. VERT.
REINFORCEMENT.
4. PROVIDE VERT. BARS AT JAMBS OF ALL OPENINGS.
FOR OPENINGS W/ WIDTH < 3'-4" PROVIDE VERT. BARS AT FIRST TWO CORES AT EACH JAMB.
FOR OPENINGS W/ WIDTH > 3'-4" < 8'-0" PROVIDE VERT. BARS AT FIRST THREE CORES AT EACH
JAMB.
BAR SIZE TO MATCH TYP. VERT. REINFORCEMENT.
5. PROVIDE VERT. BAR AT FIRST CORE ON EACH SIDE OF CONTROL JOINTS. BAR SIZE AND SPACING TO MATCH TYP. VERT.
REINFORCEMENT.
6. PROVIDE HORIZONTAL BOND BEAM W/ 1-#5 CONT. BELOW ALL WINDOW OPENINGS. EXTEND 2'-0" PAST
OPENING.
7. SPLICE ALL REINFORCEMENT PER TABLE THIS SHEET.
NOTES:
REINFORCEMENTCMU SIZE REMARKSMARK TYPE
CMU WALL SCHEDULE
#5 @ 32" OCAM6 6"
1/
D 1/
D
#3
MASONRY CONSTRUCTION
LAP SPLICE LENGTHS
1'-6"
#4 2'-0"
#5 2'-6"
#6 3'-0"
#7 3'-6"
#8 4'-0"
#9 4'-6"
FS
FS
FS
FS
THICKENED SLAB (TS), TYPICAL
AT INTERIOR BEARING WALLS
TYP, UNO
SB301
TYP
SB301
TYP7
SB301
TYP
TYP
SB301
30' - 5 1/8"15' - 8 3/4"35' - 6 1/2"35' - 0 1/4"
/8
/2
/8
/4
4' - 0"33' - 6 5/8"21' - 5"2' - 0"
3'
/2
/2
/2
7/ 8"
15' - 11 3/8"12' - 5 1/8"9' - 11 3/4"28' - 9 3/4"
/2
/8
/4
/2
116' - 8 5/8"
7' - 4 3/4"
7'
3/ 4"
60' - 11 5/8"
/4
5' - 4 7/8"
2' - 11"20' - 6 3/8"8' - 1 3/4"20' - 7"5' - 7 5/8"
4' - 0"
3' - 1 1/4"
7'
/8
/2
8'
/8
/2
20' - 7 1/8"
19' - 4 7/8"8' - 7 5/8"29' - 2"47' - 11 7/8"
12' - 11 1/4"19' - 7 1/8"
8' - 8"5' - 2 3/8"
3'
3/ 8"
12' - 8 3/8"
11' - 5 3/4"
T/FTG = 100' - 0"
8'
/8
SECTION LENGTH NOTES
CMU WALL LINTEL SCHEDULE
NOTES:
1. PROVIDE MIN 8" BEARING FOR LINTELS, UNO
BOND BEAM W/ 2 - #5 CONT BAR
SOLID GROUTED COURSES
OF BLOCK. POUR GROUT AT
SAME TIME AS BOND BEAM
H
W
3" C
LR
M
A X
6" WIDE X 16" TALL
6" WIDE X 24" TALL
8" TO 4'-0"
4'-1" TO 6'-8"
TYPE
A
A
TYPE "A"
th re e-qu ar te rs in ch o ne fo ot on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot
B th re e in ch es o ne fo ot
SCALE
PROJECT PRINCIPAL
PROJECT ARCHITECT
ELECTRICAL ENGINEER
PROJECT MANAGER
MECHANICAL ENGINEER
Use or disclosure of data contained on this sheet is subject to the restriction on the title page of this proposal.
Robinson
Robinson
Fischer
Gobreski
Daller
Danville, IL
Drawing Title
Approved:
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
B
A
C
D
E
F
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veteran Affairs
LANDSCAPE ARCHITECT
CIVIL ENGINEER
STRUCTURAL ENGINEER
Cyr
Meneley
VanderWoude
PLUMBING ENGINEER Daller
CONSTRUCTION DOCUMENTS 06/21/2017
550-316
One Indiana Square, Suite 2100 Indianapolis, IN 46204
United States P: 317 532 5400 F: 317 532 5499 www.URScorp.com
/1
/2
:1 :5
P
M C
U s e rs \b th o m a s \ D o c u m e n ts
\1 .1
V A
D a n v ill e G re e n H o m e s b th o m a s .r v t
SB111
COURAGE - FOUNDATION PLAN
WJTMAV2017.06.21
VA DANVILLE - CONSTRUCT TWO
GREEN HOMES
URS PROJECT NO. 25628010
FOOTING SCHEDULE
MARK
FOOTING SIZE
FOOTING REINFORCEMENT REMARKS
WIDTH DEPTH
F4.0 4' - 0" 1' - 0" (4) #5 EA WAY
TS
WF36 3' - 0" 1' - 0" (3) #5 CONT
WF48 4' - 0" 2' - 0" (4) #5 CONT
CONCRETE WALL SCHEDULE
MARK WALL THICKNESS
HORIZONTAL REINF VERTICAL REINF
REMARKSINSIDE FACE OUTSIDE FACE INSIDE FACE OUTSIDE FACE
CW8 8" #5 @ 12" OC - #5 @ 12" OC - CENTER REINF IN WALL
N
SCALE: 1/8" = 1'-0"SB111
1 COURAGE - FOUNDATION PLAN
GENERAL FOUNDATION NOTES
1. ALLOWABLE DESIGN BEARING PRESSURE FOR SPREAD FOOTINGS = 2000 PSF, ALLOWABLE DESIGN BEARING PRESSURE FOR CONTINUOUS WALL FOOTINGS = 2000 PSF.
CONTRACTOR TO VERIFY IN FIELD AND SHALL NOTIFY ENGINEER OF ANY EXISTING SOILS AT BEARING ELEVATION THAT ARE UNACCEPTABLE FOR FOOTING SUPPORT. ALLOWABLE FOOTING PRESSURE IS BASED ON GEOTECHNICAL REPORT NUMBER 170GC00110 PREPARED BY CARDNO ATC DATED APRIL 30, 2015.
2. WHERE FOUNDATION SUBGRADE IS INADVERTENTLY OVEREXCAVATED, OR WHERE UNSUITABLE SOILS ARE ENCOUNTERED FOR SLAB SUPPORT, REMOVE ALL DISTURBED/UNSUITABLE SOIL AND REPLACE TO PROPER GRADE WITH LEAN CONCRETE OR GRANULAR FILL (CA-6 OR EQUIVALENT) COMPACTED TO 95% OF STANDARD PROCTOR
DENSITY.
3. COORDINATE LOCATION OF ALL UTILITIES THROUGH OR UNDER FOUNDATIONS WITH MEP SHEETS.
4. COORDINATE WALL LOCATIONS WITH ARCH. DRAWINGS.
5. COORDINATE WALL OPENINGS WITH ARCH. DRAWINGS.
6. CONTRACTOR TO DESIGN ALL COLUMN BASE PLATES TO BE HIDDEN IN WALLS.
eric.slaughter
SLAB PLAN LEGEND
AREA OF DEPRESSED SLAB, SEE DETAIL 6/SB301
SLOPED FLOOR AREA. PITCH FLOOR TO DRAIN.
SLOPE SHALL NOT EXCEED 1/8 INCH PER FOOT.
INDICATES CONTROL OR CONSTRUCTION JOINT
SEE DETAIL 1/SB301.
3' - 0"
SLOPED FLOOR
6' - 10 1/2"7' - 7 1/2"3' - 0"
SLOPED FLOOR
6' - 10 1/2"7 1/4"
SLOPED FLOOR
6' - 10 1/2"3' - 0"14' - 7 3/4"3' - 0"
SLOPED FLOOR
6' - 11 5/8"7' - 6 3/8"3' - 0"
SLOPED FLOOR
6' - 11 1/8"
5'
S
LO
P E
D F
LO
O
R
6'
1"
3'
7'
S
LO
P E
D F
LO
O
R
6'
1"
3'
/4
3'
S
LO
P E
D F
LO
O
R
6'
1"
1/
4"
S
LO
P E
D F
LO
O
R
6'
1"
3'
/8
3'
S
LO
P E
D F
LO
O
R
6'
1"
10' - 2 1/4"5' - 2"
5'
/2
S
LO
P E
D F
LO
O
R
/8
/8
3' - 1 1/8"3' - 0"9' - 0 1/4"
SLOPED FLOOR
15' - 1 3/8"
5' - 2"
14' - 2 1/4"5' - 2"
SB301
TYP
SB301
TYP
5' - 2" 14' - 10 1/4"
4" SLAB ON GRADE WITH FIBER
MESH REINFORCEMENT
th re e-qu ar te rs in ch o ne fo ot on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot
B th re e in ch es o ne fo ot
SCALE
PROJECT PRINCIPAL
PROJECT ARCHITECT
ELECTRICAL ENGINEER
PROJECT MANAGER
MECHANICAL ENGINEER
Use or disclosure of data contained on this sheet is subject to the restriction on the title page of this proposal.
Robinson
Robinson
Fischer
Gobreski
Daller
Danville, IL
Drawing Title
Approved:
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
B
A
C
D
E
F
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veteran Affairs
LANDSCAPE ARCHITECT
CIVIL ENGINEER
STRUCTURAL ENGINEER
Cyr
Meneley
VanderWoude
PLUMBING ENGINEER Daller
CONSTRUCTION DOCUMENTS 06/21/2017
550-316
One Indiana Square, Suite 2100 Indianapolis, IN 46204
United States P: 317 532 5400 F: 317 532 5499 www.URScorp.com
/1
/2
:1 :0
P
M C
U s e rs \b th o m a s \ D o c u m e n ts
\1 .1
V A
D a n v ill e G re e n H o m e s b th o m a s .r v t
SB112
COURAGE - SLAB PLAN
WJTMAV2017.06.21
VA DANVILLE - CONSTRUCT TWO
GREEN HOMES
URS PROJECT NO. 25628010
N
SCALE: 1/8" = 1'-0"SB112
1 COURAGE - SLAB PLAN
eric.slaughter
CONTROL JOINT
CONSTRUCTION JOINT
COAT OR WRAP TO
PREVENT BOND
SMOOTH DOWEL
BAR PER TABLE
DOWEL SIZE AND SPACING
DOWEL
DIAMETER
IN
SLAB
DEPTH
TOTAL DOWEL
LENGTH
DOWEL SPACING
CENTER TO CENTER
IN IN IN
3/44 16 24
T/SLAB
1/
X S
LA
B
T H
IC
K
N E
S S
1/4" (+/-) SAWCUT JOINT
T/SLAB
1 (MAX.)
ALTER EXCAVATION LIMITS
1' - 6"
CLASS B TENSION LAP
PER SCHEDULE
T/FTG
T/FTG
EQ.
BARS TO MATCH
FOOTING REINF. SIZE
AND SPACING
F S
INDICATES
FOOTING STEP
F S
F S
4'-0" MIN.
2' -0
M
A X
1' - 7"
CLASS B TENSION LAP
PER SCHEDULE
C
LR2"
SEAL VOID WITH…