36E77619B0003-006.pdf

PDF 18 MB Posted

Attached to
Construct Two New Green Homes 5 & 6 Minor - Danville VAMC
Solicitation number
36E77619B0003
Issued by

About this file

36E77619B0003 ATTACHMENT 6 - Drawings 2 of 7.pdf

View the file

Other files

File Type Posted
36E77619C0023-000.docx DOCX document
36E77619B0003-0003002.pdf PDF
36E77619B0003-0003003.pdf PDF
36E77619B0003-0003004.pdf PDF
36E77619B0003-0003005.pdf PDF
36E77619B0003-0003000.docx DOCX document
36E77619B0003-0003006.pdf PDF
36E77619B0003-0003001.pdf PDF
36E77619B0003-0002000.docx DOCX document
36E77619B0003-0001001.pdf PDF
36E77619B0003-0001000.docx DOCX document
36E77619B0003-000.docx DOCX document
36E77619B0003-013.docx DOCX document
36E77619B0003-005.pdf PDF
36E77619B0003-012.pdf PDF
36E77619B0003-002.pdf PDF
36E77619B0003-009.pdf PDF
36E77619B0003-007.pdf PDF
36E77619B0003-011.pdf PDF
36E77619B0003-001.pdf PDF
36E77619B0003-003.pdf PDF
36E77619B0003-010.pdf PDF
36E77619B0003-004.pdf PDF
36E77619B0003-008.pdf PDF
36E77619B0003.docx DOCX document
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S SS S

o oo o

R E

F

DB

OV REF

FD

FD

FD

FD

FD FD

F R

Z

D W

FD

S SS S S S S S S S S S S S S S S S S S S

o oo o o o o o o o o o o o o o o o o o o o o o o o o oo o oo ooooooooooooooooo o o o o o o o o o o o o o o o o o o o oo o o o o o o o o o o o o o

S SS S S S S S S S S S S S SS

S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S

S S

S S

S S

S S

S S

S S

S SS S S S S S S S S

S SS S S S S S S S S S S

S S

S

S S

S S

S SS S S S S

S SS S S S S

S

S SS S

S

S S

S S

S

S S

S

S S

S S

S S

S S

FD

FD

FD

FD

FDFDFDFDFD

FD

R E

F

DB

OVREF

F R

Z

D W

SS SSSSSSSSSSSSSSSSSSS

oo oooo o o o o o o o o o o o o o o o o o o o o o oo o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o oo ooooooooooo o o o

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S

SS

S S

S S

S S

S S

S S

S S

S S

S S

S S

S

S S

S S

S S

S S

S S

S S

SS SSSSSSSSS

SS SSSSSSSSSSS

o oo o

SS SSSSSSSSSSSSS

S S

S

S S

S S

SS SSSSS

SS SSSSS

S

SS S

S

SSS

S S

S

S S

S S

S S

S S

S S

S

ONE HOUR FIRE RESISTIVE WALL ASSEMBLY

SMOKE PARTITION, CONSTRUCTION TO BE SMOKE

TIGHT, WALL IS NOT RATED

ONE HOUR FIRE RATED SMOKE COMPARTMENT WALL

EGRESS CORRIDOR(S)

EXIT / EGRESS

LIFE SAFETY - SYMBOLS

THERAPY

i116

BEDROOM

i115

BEDROOM

i113

BEDROOM

i112

BEDROOM

i111

BEDROOM

i109

BEDROOM

i108

BEDROOM

i107

BEDROOM

i106 BEDROOM i105

TOILET

i126

LAUNDRY

i127

OFFICE

i130

ELECTRICAL

i131SPD i129

SOILED

i128

PANTRY

i103B

GARAGE

i117

LIVING

i104

DINING

i102

CORRIDOR

i132

VESTIBULE

i101

SCREENED PORCH

i135

STORAGE

i124

UTILITY

i120

STORAGE

i125

BATHROOM

i115C

BATHROOM

i113C

BATHROOM

i112C

BATHROOM

i111C

BATHROOM

i109C

BATHROOM

i108C BATHROOM i107C

BATHROOM

i106C

BATHROOM

i105C

CLOSET

i105B

CLOSET

i106B

CLOSET

i107B

CLOSET

i108B

CLOSET

i109B

CLOSET

i111B

CLOSET

i112B

CLOSET

i113B

CLOSET

i115B

PATIO

i136

PORCH

CLOSET

i101B

KITCHEN

i103

LINEN

i123

BARIATRIC BEDROOM

i114

BATHROOM

i114C

CLOSET

i114B

CLOSET

i133

SPA

i122

HSKP

i118

VESTIBULE

i110

O2 i119

DATA

i121

DEN

c116

BEDROOM

c115

BEDROOM

c113

BEDROOM

c112

BEDROOM

c111

BEDROOM

c109

BEDROOM

c108

BEDROOM

c107

BEDROOM

c106BEDROOM c105

GARAGE

c117

LIVING

c104

DINING

CORRIDOR

VESTIBULE

c101

SCREENED PORCH

c135

STORAGE

c124STORAGE c125

BATHROOM

c115C

BATHROOM

c113C

BATHROOM

c112C

BATHROOM

c111C

BATHROOM

c109C

BATHROOM

c108CBATHROOM c107C

BATHROOM

c106C

BATHROOM

c105C

CLOSET

c105B

CLOSET

c106B

CLOSET

c107B

CLOSET

c108B

CLOSET

c109B VESTIBULE c110

CLOSET

c111B

CLOSET

c112B

CLOSET

c113B

CLOSET

c115B

PATIO

PORCH

c134

CLOSET

c101B

KITCHEN

c103

LINEN

c123

BARIATRIC BEDROOM

c114

BATHROOM

c114C

CLOSET

c114B

CLOSET

c133

ELECTRICAL

c131

PANTRY

c103B

OFFICE

c130

SOILED

c128

LAUNDRY

c127

SPD

c129

TOILET

c126

SPA

c122

UTILITY

c120

HOUSEKEEPING

c118

O2 c119

DATA

c121

APPLICABLE CODES & STANDARDS

• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, AND VA NATIONAL CAD STANDARD APPLICATION

GUIDE

• INTERNATIONAL BUILDING CODE (IBC) 2015 EDITION [ SEE NOTES BELOW ]

• NFPA 101 LIFE SAFETY CODE (LSC) 2015 EDITION [ SEE NOTES BELOW ]

• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS

• VA SEISMIC DESIGN REQUIREMENTS, H-18-8

• NATIONAL ELECTRICAL CODE (NEC)

• NATIONAL STANDARD PLUMBING CODE (NSPC)

• UNIFORM FEDERAL ACCESSIBILITY STANDARDS (UFAS) INCLUDING VA SUPPLEMENT, BARRIER FREE DESIGN

• VA MASTER CONSTRUCTION SPECIFICATION

NOTES:

1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES

A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY CONSERVATION. VA BUILDINGS MUST MEET REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCE BY NFPA 101. DESIGN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE.

FOR ITEMS ADDRESSED BY BOTH THE IBC AND NFPA 101 OR A DOCUMENT REFERENCED BY THE NFPA 101, THE NFPA 101 OR REFERENCED DOCUMENTS SHALL BE USED EXCLUSIVELY (THIS APPLIES EVEN IF THE IBC REQUIREMENTS DIFFER).

2. CONFLICTS BETWEEN NATIONAL RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS - SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONAL RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF THE VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE

AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.

CODE ANALYSIS

OCCUPANCY CLASSIFICATION HEALTHCARE ( 6.1.5, 6.1.5.1) I-2 ( 3.10.6 )

BUILDING HEIGHT & AREA (MAX FOR CONSTRUCTION TYPE) 1 STORY ( TABLE 18.1.6.1 ) 1 STORY / 9500 SF

CONSTRUCTION TYPE & FIRE RESISTANCE RATINGS V ( 8.2.1.2, NFPA 220 5A ( 602.1, 602.5 )

STRUCTURAL FRAME 1 HOUR ( TABLE A8.2.1.2 ) 1 HOUR* ( TABLE 601 )

EXTERIOR BEARING WALLS 1 HOUR ( TABLE A8.2.1.2 ) 1 HOUR ( TABLE 601 )

INTERIOR BEARING WALLS 1 HOUR ( TABLE A8.2.1.2 ) 1 HOUR* ( TABLE 601 )

EXTERIOR NON-BEARING WALLS & PARTITIONS 0 HOURS ( TABLE A8.2.1.2 ) 0 HOURS ( TABLE 601 ) INTERIOR NON-BEARING WALLS AND PARTITIONS 0 HOURS ( TABLE A8.2.1.2 ) 0 HOURS ( TABLE 601 ) FLOOR CONSTRUCTION AND SECONDARY MEMBERS 1 HOUR ( TABLE A8.2.1.2 ) 0 HOURS ( TABLE 601 ) ROOF CONSTRCTION AND SECONDARY MEMBERS 1 HOUR ( TABLE A8.2.1.2 ) 1 HOUR* ( TABLE 601 )

* FOR IBC 2015, AN APPROVED AUTOMATIC SPRINKLER SYSTEM IS ALLOWED TO BE SUBSTITUTED FOR 1-HOUR FIRE-RATED CONSTRUCTION, PROVIDED SUCH SYSTEM IS NOT OTHERWISE REQUIRED BY OTHER PROVISIONS OF THE CODE OR USED FOR AN ALLOWABLE AREA INCREASE.

THE 1-HOUR SUBSTITUTION FOR THE FIRE RESISTANCE OF EXTERIOR WALLS SHALL NOT BE PERMITTED.

MEANS OF EGRESS

HEALTHCARE / I-2 EGRESS REQUIREMENTS CHAPTER 7 ( 18.2 ) CHAPTER 10

TRAVEL DISTANCE ( MAX WITH SPRINKLER SYSTEM ONLY ) 200 FEET ( 18.2.6.2.1 ) 200 FEET ( TABLE 1016.1 )

NUMBER OF EXITS ( PER STORY ) 2 ( 18.2.4.1, 18.2.4.2 ) 2 ( TABLE 1021.1 )

th re e-qu ar te rs in ch o ne fo ot on e-qu ar te r in ch o ne fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot

B th re e in ch es o ne fo ot

PROJECT PRINCIPAL

PROJECT ARCHITECT

ELECTRICAL ENGINEER

PROJECT MANAGER

MECHANICAL ENGINEER

Use or disclosure of data contained on this sheet is subject to the restriction on the title page of this proposal.

Robinson

Robinson

Fischer

Gobreski

Daller

Danville, IL

Drawing Title

Approved:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veteran Affairs

LANDSCAPE ARCHITECT

CIVIL ENGINEER

STRUCTURAL ENGINEER

Cyr

Meneley

VanderWoude

PLUMBING ENGINEER Daller

CONSTRUCTION DOCUMENTS 06/21/20171

7/

/2

8:

:5

A

M C

:\U se rs \e ric _s la ug ht er

\D oc um en ts \V

A G re e n

H om es A r c h_ er ic

.s la ug ht er .r vt

AS001

LIFE SAFETY PLAN

ARTE2017.06.21

VA Danville - Green Homes One Indiana Square, Suite 2100

Indianapolis, IN 46204 United States

P: 317 532 5400 F: 317 532 5499 www.URScorp.com

URS PROJECT NO. 25628011

550-316

AS001 Scale: 1/8" = 1'-0"

1 FIRST FLOOR LIFE SAFETY PLAN - INDEPENDENCE

AS001 Scale: 1/8" = 1'-0"

2 LIFE SAFETY PLAN - COURAGE

eric.slaughter Text Box 132 & 133

Wall 'A'

Top

Plan

Base

Wall 'N' - 2 HR.

UL U906

DECK ABOVE

SEE STRUCT DWGS

FOR LATERAL BRACINGDOUBLE TOP PLATE

STRUCTURE ABOVE

WOOD STUDS @ 16" O.C. MAX

BATT INSULATION

5/8" GYPSUM BOARD EACH

SIDE

WOOD SOLE PLATE

SCHEDULED BASE

Wall 'C.f.' - 60 min.

UL U311

DOUBLE TOP PLATE

STRUCTURE ABOVE

WOOD STUDS @ 16" O.C.

MAX

BATT INSULATION

5/8" GYPSUM BOARD EACH

SIDE

WOOD SOLE PLATE

SCHEDULED BASE

RESILIENT CHANNEL ON (1)

SIDE OF STUD FRAMING @ 24"

O.C. VERTICALLY

Wall 'B'

DOUBLE TOP PLATE

STRUCTURE ABOVE

WOOD STUDS @ 16" O.C. MAX

5/8" GYPSUM BOARD, ONE (1)

SIDE

WOOD SOLE PLATE

SCHEDULED BASE

Wall 'C'

DOUBLE TOP PLATE

STRUCTURE ABOVE

WOOD STUDS @ 16" O.C.

MAX

WOOD SOLE PLATE

SCHEDULED BASE

5/8" GYPSUM BOARD EACH

SIDE

SCHEDULED BASE

WOOD FURRING, BOTH

SIDES @ 24" O.C.

VERTICALLY

5/8" GYPSUM BOARD

EACH SIDE

Wall 'M'

DECK ABOVE

SEE STRUCT DWGS

FOR LATERAL BRACING

6" CMU6" CMU

TYPE

A4

A6

WALL DEPTH

6 3/4"

4 3/4"

COMMENTS

UL U305 = 60 MIN. WALL

UL U279 = 60 MIN. WALL

TYPE

B4

B6

WALL DEPTH

6 1/8"

4 1/8"

COMMENTS

TYPE

C4

C6

WALL DEPTH

6 3/4"

4 3/4"

COMMENTS

TYPE

Cf4

Cf6

WALL DEPTH

7 1/2"

5 1/2

COMMENTS

TYPE

M6

M8

WALL DEPTH

7 5/8"

5 5/8"

COMMENTS

TYPE

N6

N8

WALL DEPTH

10 5/8"

8 5/8"

COMMENTS

1. PARTITION TYPES ARE INDICATED ON THE FLOOR PLANS USING THE

SYMBOL INDICATED.

2. WHERE PARTITION TYPES ARE INDICATED, THE PARTITION TYPE IS

CONTINUOUS UNTIL THE PARTITION TYPE CHANGES DIRECTIONS

OR A DIFFERENT PARTITION TYPE IS INDICATED.

3. PARTITIONS ARE TYPICALLY DIMENSIONED FROM FACE OF

PARTITION TYPE TO COLUMN CENTER LINE OR FACE OF PARTITION

TYPE TO FACE OF PARTITION TYPE, UNLESS OTHERWISE NOTED.

4. PROVIDE SOUND ATTENUATING FIRE BLANKET INSULATION AS

NOTED IN PARTITION TYPES. MAINTAIN SOUND RATING BY SEALING

PARTITION TYPE AT THE STRUCTURE, FLOOR AND AT ALL

PENETRATIONS.

5. AT ALL FIRE RESISTANCE RATED OR SMOKE TIGHT CONSTRUCTION,

SEAL WALL TYPE CONSTRUCTION AT STRUCTURE, FLOOR AND AT

ALL PENETRATIONS.

6. FINISHES ON PARTITION SYSTEMS EXTEND TO PLASTER/GYPSUM

WALLBOARD CEILING SYSTEMS (UON).

7. FINISHES ON PARTITION SYSTEMS EXTEND TO 4" ABOVE

ACOUSTICAL CEILING SYSTEMS (UON). TAPE AND SEAL ALL JOINTS

ABOVE THE CEILING.

PARTITION TYPE NOTES

A. ALL INTERIOR STUDS ARE TO BE SPACED NOT LESS THAN 1'-4" ON

CENTER.

B. PROVIDE DOUBLE STUDS AT EACH SIDE OF ALL OPENINGS FROM

FLOOR TO TOP RUNNER.

C. ALL GYPSUM BOARD USED SHALL BE 5/8" TYPE X UNLESS

OTHERWISE NOTED.

D. REFER TO ROOM FINISH SCHEDULE FOR ALL WALL FINISHES.

E. MAINTAIN CONTINUITY OF FIRE RATED PARTITIONS AT INTERSECTIONS

OF NON-RATED OR LESSER RATED PARTITIONS.

F. ALL PARTITIONS ARE FULL HEIGHT, TIGHT TO DECK ABOVE UNLESS

NOTED OTHERWISE.

GYB= GYPSUM BOARD

CBB= CEMENT BACKER BOARD

REMARKS- (see schedule for location)

GENERAL PARTITION NOTES

ARCH. GRAPHIC SYMBOLS

CL

SIM

R101| A103

DETAIL NUMBER

SHEET WHERE DETAIL IS

INDICATED

x y

W z

EGRESS NUMBER OF OCCUPANTS

OPENING WIDTH

EGRESS WIDTH PER OCCUPANT

EGRESS CAPACITY

NORTH ARROW

C2

DRAWING REVISION

ROOM NAME

ROOM NAME

ROOM NUMBER

SIM

A102

WALL SECTION NUMBER

SHEET WALL SECTION IS

SHOWN

F 1

DIRECTION OF SECTION

VIEW

SIM

A102

BUILDING SECTION NUMBER

SHEET SECTION IS SHOWN

DIRECTION OF SECTION VIEW

DOOR NUMBER

PANEL TYPE

FRAME TYPE

1i

WINDOW TYPE

SHEET NOTE

SHEET WHERE DETAIL IS SHOWN

CEILING TYPE

CEILING HEIGHT

C2 WALL TYPE

CENTER LINE

DIRECTION OF ELEVATION VIEW

ELEVATION NUMBERA101

SHEET ELEVATION IS SHOWN

1'-0" ACT-x

SIM

A102

Ref

1R ef

1 R ef

Ref

ARCHITECTURAL ABBREVIATIONS

AFF ABOVE FINISH FLOOR

ALUM ALUMINUM

BD BOARD

B.O. BOTTOM OF____

CG CORNER GUARD

CJ CONTROL JOINT

CMU CONCRETE MASONRY UNIT

COL COLUMN

CONC CONCRETE

CONT CONTINUOUS

DIA DIAMETER

DLO DAYLIGHT OPENING

DN DOWN

EJ EXPANSION JOINT

EL ELEVATION

ETR EXISTING TO REMAIN

FEC FIRE EXTINGUISHER CABINET

FIN FINISH

FND FOUNDATION

FL FLOOR

FTG FOOTING

GALV GALVANIZED

GYP GYPSUM

HP HIGH POINT

HM HOLLOW METAL

INSUL INSULATED

LF LINEAR FOOT

MAX MAXIMUM

MID MIDDLE

MIN MINIMUM

MO MASONRY OPENING

NA NOT APPLICABLE

NIC NOT IN CONTRACT

NTS NOT TO SCALE

OC ON CENTER

OPNG OPENING

OPP OPPOSITE

OPR OPERABLE

R RISER

RAD RADIUS

REF REFERENCE

RO ROUGH OPENING

SAFB SOUND ATTENUATION FIRE BLANKET

SAFM SPRAY APPLIED FIREPROOF MATERIAL

SF SQUARE FOOT

S.S. STAINLESS STEEL

TERM TERMINATION

T TREAD

T.O. TOP OF____

TYP TPICAL

UNO UNLESS NOTED OTHERWISE

RCP REFELCTED CEILING PLAN

W/ WITH

WD WOOD

DOUBLE TOP PLATE

BUILT-UP HEADER

SCHEDULED OPENING

REDUNDANT CRIPPLE STUD

FRAMING

2x FRAMING @ 16" O.C.

th re e-qu ar te rs in ch o ne fo ot on e-qu ar te r in ch o ne fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot

B th re e in ch es o ne fo ot

PROJECT PRINCIPAL

PROJECT ARCHITECT

ELECTRICAL ENGINEER

PROJECT MANAGER

MECHANICAL ENGINEER

Use or disclosure of data contained on this sheet is subject to the restriction on the title page of this proposal.

Robinson

Robinson

Fischer

Gobreski

Daller

Danville, IL

Drawing Title

Approved:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veteran Affairs

LANDSCAPE ARCHITECT

CIVIL ENGINEER

STRUCTURAL ENGINEER

Cyr

Meneley

VanderWoude

PLUMBING ENGINEER Daller

CONSTRUCTION DOCUMENTS 06/21/20171

7/

/2

8:

:0

A

M C

:\U se rs \e ric _s la ug ht er

\D oc um en ts \V

A G re e n

H om es A r c h_ er ic

.s la ug ht er .r vt

AS002

GENERAL NOTES & WALL TYPES

ARTE2017.06.21

VA Danville - Green Homes One Indiana Square, Suite 2100

Indianapolis, IN 46204 United States

P: 317 532 5400 F: 317 532 5499 www.URScorp.com

URS PROJECT NO. 25628011

550-316

Scale: 3/4" = 1'-0"

Wall Types AS002 Scale: 1/2" = 1'-0"

2 WALL FRAMING DETAIL

eric.slaughter

WALL CONSTRUCTION (REFER TO WALL

BASE DETAIL FOR ADDITIONAL

MATERIAL INFORMATION)

CEILING SYSTEM (REFER TO ROOM

FINISH SCHEDULE)

UNDERSIDE OF FLOOR OR

ROOF DECK ABOVE

PROVIDE 2 1/2" (22 GA.) METAL STUD

KICKER @ 4'-0" O.C.

WHERE PARTITION STUD LENGTH

EXCEEDS MAX. HT. (REFER TO INTERIOR

PARTITION TYPE SCHEDULE)

WALL CONSTRUCTION (REFER TO WALL

BASE DETAIL FOR ADDITIONAL MATERIAL

INFORMATION)

CEILING SYSTEM (REFER TO

ROOM FINISH SCHEDULE)

MIN. BOTH SIDES

1' - 0" 4"

M

IN

8"

M A

X

.UNDERSIDE OF FLOOR OR

ROOF DECK ABOVE

WALL CONSTRUCTION (REFER TO WALL

BASE DETAIL FOR ADDITIONAL MATERIAL

INFORMATION)

CEILING SYSTEM (REFER TO

ROOM FINISH SCHEDULE)

A

LL

O W

A N

C E

1" S

T R

U C

T

D E

F

LE

C T

IO

N

UNDERSIDE OF FLOOR OR

ROOF DECK ABOVE

PROVIDE 2 1/2" (22 GA.) METAL STUD KICKER

@ 4'-0" O.C. WHERE PARTITION STUD LENGTH

EXCEEDS MAX. HT. (REFER TO

INTERIOR PARTITION TYPE SCHEDULE)

WALL CONSTRUCTION (REFER TO WALL

BASE DETAIL FOR ADDITIONAL MATERIAL

INFORMATION)

CEILING SYSTEM (REFER TO

ROOM FINISH SCHEDULE)

8" M

A X

A

LL

O W

A N

C E

1" S

T R

U C

T

D E

F

LE

C T

T

IO

N

4" M

IN

UNDERSIDE OF FLOOR OR ROOF DECK

ABOVE

CONCRETE BOND BEAM GROUT FILLED WITH

(2) #4 BARS

WALL CONSTRUCTION (REFER TO WALL

BASE DETAIL FOR ADDITIONAL MATERIAL

INFORMATION)

CEILING SYSTEM (REFER TO

ROOM FINISH SCHEDULE)

UNDERSIDE OF FLOOR OR

ROOF DECK ABOVE

4" M

IN

A

LL

O W

A N

C E

1" S

T R

U C

T

D E

F

LE

C T

IO

N

GYPSUM BOARD ON STUD

PARTITION (AS SCHEDULED)

SEALANT AND BACKING/BOND BREAKING MATERIAL CONTINUOUS,

BOTH SIDES PROVIDE ACOUSTICAL SEALANT @ NON-FIRE RATED

PARTITONS AND FIRESTOPPING @ FIRE RATED PARTITIONS

(REFER TO REFLECTED CEILING PLANS FOR LOCATIONS OF FIRE

RATED PARTITIONS)

METAL BEADED EDGE TRIM CONTINIOUS EACH SIDE OF JOINT,

TYP.

09260.M EACH SIDE OF JOINT, TYP.

07900.B TO FILL JOINT @ NON-FIRE RATED PARTITIONS -

PROVIDE 07840.A @ FIRE RATED PARTITIONS (REFER TO

REFLECTED CEILING PLANS FOR LOCATIONS OF FIRE RATED

PARTITIONS)

METAL BEADED EDGE TRIM TYP. @ ALL EXPOSED CORNERS AND

WALL ENDS

GYPSUM BOARD ON STUD PARTITION (AS SCHEDULED)

SEALANT CONTINUOUS ALONG JOINT

ACOUSTICAL SEALANT @ ALL CORNER JOINTS OF NON-FIRE RATED

PARTITIONS

P A

R T

IT

IO

N N

O N

-R A

T E

D P

A R

T

IT

IO

N

F

IR

E R

A T

E D

FIRE RATED

PARTITION

FIRE-RESISTANT JOINT SEALANT @ ALL

CORNER JOINTS OF FIRE RATED

PARTITIONS

NOTE: PROVIDE CONTINUITY OF

FIRE RATED PARTITIONS @ CORNERS AS

ILLUSTRATED (REFER TO REFLECTED

CEILING PLANS FOR LOCATIONS OF FIRE

RATED PARTITIONS)

CONCRETE MASONRY

UNITS (AS SCHEDULED)

SEALANT AND BACKING/BOND BREAKING MATERIAL

CONTINUOUS BOTH SIDES PROVIDE FIRE-RESISTANT SEALANT

@ FIRE-RATED PARTITIONS (REFER TO

REFLECTED CEILING PLANS FOR LOCATIONS OF FIRE-RATED

PARTITIONS)

PREFORMED FOAM SEALANT TO FILL JOINT @ NON-FIRE

RATED PARTITIONS PROVIDE FIRESTOPPING INSULATION @

FIRE RATED PARTITIONS (REFER TO REFLECTED CEILING

PLANS FOR LOCATIONS OF FIRE RATED PARTITIONS)

CONTROL JOINT SEAL CONTINUOUS FULL HEIGHT OF

PARTITION

CONCRETE MASONRY UNITS (AS

SCHEDULED)

HORIZONTAL JOINT REINFORCING @ 16"

O.C.

PREFORMED FOAM SEALANT TO FILL JOINT

WITH SEALANT AND BACKING/ BOND-

BREAKING MATERIAL

CONCRETE MASONRY UNITS (AS

SCHEDULED)

WIRE FABRIC MESH @ COURSE BELOW

ANCHOR TO SUPPORT GROUT FILL

CORE ABOVE AND BELOW ANCHOR

STEEL BAR ANCHOR 1/4 x3X 30" LONG

WITH BENT ENDS @ 4'-0" O.C. VERTICAL

GROUT FILL CMU CORES @ BENT ENDS

FIRE-RESISTANT INSULATION TO FILL

JOINT WITH FIRE-RESISTANT JOINT

SEALANT CONTINUOUS, BOTH SIDES

WALL PARTITION AS SCHEDULED -

SEE FLOOR PLANS

(4) ANCHOR BOLTS, TYPICAL

UP-SWINGING GRAB BAR

T O

F

IN

IS

H

F

LO

O R

2'

2' - 2"

HINGE PIN

ACHOR WALL TO SLAB BELOW AS REQUIRED

BY UP-SWING GRAB BAR MANUFACTURER

th re e-qu ar te rs in ch o ne fo ot on e-qu ar te r in ch o ne fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot

B th re e in ch es o ne fo ot

PROJECT PRINCIPAL

PROJECT ARCHITECT

ELECTRICAL ENGINEER

PROJECT MANAGER

MECHANICAL ENGINEER

Use or disclosure of data contained on this sheet is subject to the restriction on the title page of this proposal.

Robinson

Robinson

Fischer

Gobreski

Daller

Danville, IL

Drawing Title

Approved:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veteran Affairs

LANDSCAPE ARCHITECT

CIVIL ENGINEER

STRUCTURAL ENGINEER

Cyr

Meneley

VanderWoude

PLUMBING ENGINEER Daller

CONSTRUCTION DOCUMENTS 06/21/20171

7/

/2

8:

:0

A

M C

:\U se rs \e ric _s la ug ht er

\D oc um en ts \V

A G re e n

H om es A r c h_ er ic

.s la ug ht er .r vt

AS003

WALL DETAILS - TYPICAL

ARTE2017.06.21

VA Danville - Green Homes One Indiana Square, Suite 2100

Indianapolis, IN 46204 United States

P: 317 532 5400 F: 317 532 5499 www.URScorp.com

URS PROJECT NO. 25628011

550-316

AS003 Scale: 1 1/2" = 1'-0"

1 Stud Partition - To Ceiling AS003 Scale: 1 1/2" = 1'-0"

2 Stud Partition - To Above Ceiling AS003 Scale: 1 1/2" = 1'-0"

3 Stud Partition - To Deck Above AS003 Scale: 1 1/2" = 1'-0"

4 Stud Partition - To Deck Above (Single)

AS003 Scale: 1 1/2" = 1'-0"

5 CMU Partition - To Ceiling AS003 Scale: 1 1/2" = 1'-0"

6 CMU Partition - To Deck Above AS003 Scale: 1 1/2" = 1'-0"

7 Typ. Control Joint @ Stud Part.

AS003 Scale: 1 1/2" = 1'-0"

8 Typ. Framing @ Stud Partitions

AS003 Scale: 1 1/2" = 1'-0"

9 Typ. Control Joint @ CMU AS003 Scale: 1 1/2" = 1'-0"

10 Typ. Joint @ Non-Rated CMU AS003 Scale: 1 1/2" = 1'-0"

11 Typ. Joint @ Fire Rated CMU (U906) AS003 Scale: 1" = 1'-0"

12 DETAIL @ UP-SWING GRAB BARS

eric.slaughter

R E

F

DB

OV REF

FD

FD

FD

FD

FD FD

F R

Z

D W

FD

AS222 2

AS221

AS2221

AS221

THERAPY

i116

BEDROOM

i115

BEDROOM

i113

BEDROOM

i112

BEDROOM

i111

BEDROOM

i109

BEDROOM

i108

BEDROOM

i107

BEDROOM

i106

BEDROOM

i105

TOILET

i126

LAUNDRY

i127

OFFICE

i130

SPD

i129

SOILED

i128

PANTRY

i103B

GARAGE

i117

LIVING

i104

CORRIDOR

i132

VESTIBULE

i101

SCREENED PORCH

i135

STORAGE

i124

UTILITY

i120

STORAGE

i125

BATHROOM

i115C

BATHROOM

i113C

BATHROOM

i112C

BATHROOM

i111C

BATHROOM

i109C

BATHROOM

i107C

BATHROOM

i106C

BATHROOM

i105C

CLOSET

i105B

CLOSET

i106B

CLOSET

i107B

CLOSET

i109B

VESTIBULE

i110

CLOSET

i111B

CLOSET

i112B

CLOSET

i113B

CLOSET

i115B

PATIO

i136

PORCH

AS322

i115C i116A i113 i111 i112 i1 i1 i1 i115 i1 i112C i113C i111C i1

C i1

C i1

C i1

C i123 i1 i127 i128 i129 i1 i1

B i1

C i135B i1

A i1

B i1

A i1 i117B i1

A i120A i1 i115B i113B i111B i109B i107B i106B i105B i1

C i132A i1

B

CLOSET

i101Bi101B i1

LINEN

i123

BARIATRIC BEDROOM

i114

BATHROOM

i114C

CLOSET

i114B i114C i114B i114

CLOSET

i133

CORRIDOR

i132

CORRIDOR

i132 i1 i119

AS121

AS121

CLOSET

i108B

BATHROOM

i108C

ELECTRICAL

i131

30" HIGH

OPEN

BELOW

MICR

i1

KITCHEN

i103

IC

E i1 i116B i1

B i108B i1

C

AS321

MECH/PLUMBING

EQUIPMENT. SEE MEP

DRAWINGS.

AS421

AS422

AS422

O2 i119

DATA

i121

HSKP

i118 i118

SPA

i122

AS322

AS322

AS323

AS323

AS321

AS321

N3

C .f.

C.f.6

C.f.6

C.f.6

C.f.6

C .f.

i121 i122

C .f.

C.f.6

C4

A

A

A

A6

A

A6

54' - 10"

CL

12' - 2 1/2"

CLCL

4' - 6"

CLCL

4' - 6"

CL

12' - 3 1/2"

CL

14' - 11 1/2"

CL

6' - 5 1/2"

1/ 2"

3'

/2

/2

C L C L

3'

C L

5'

C L C L

3'

0"

C L

4'

C L

3'

4'

/4

C L

9'

/4

C L C L

4'

C L C L

4'

C L

9'

E

Q . P

A N

E

LS

6'

1/ 2"

E

Q . P

A N

E

LS

6'

1/ 4"

E

Q . P

A N

E

LS

6'

1/ 2"

/2

CLCL

4' - 6"

CLCL

4' - 6"

C L

4'

/4

2' - 0"

5' - 4 3/4"

4' - 0"

89' - 2 1/2"

20' - 5 3/4" 8' - 2 1/4" 17' - 6"

CL

5' - 6 1/2"

CL 2' - 7 3/4" CL

6' - 8 3/4"

CLCL

3' - 8 1/2"

CL

7' - 0 3/4"

35' - 5"

AS321

CL

6' - 8 3/4"

CL

6' - 8 3/4"

CLCL

3' - 8 1/2"

CLCL

14' - 6 1/2"

CLCL

3' - 8 1/2"

35' - 0"6' - 11"

CL

7' - 0 3/4"

CLCL

3' - 8 1/2"

CLCL

13' - 9 1/2"

CLCL

3' - 8 1/2"

CL

6' - 8 3/4"

7'

/2

/2

C L C L

3'

/2 "C L

6'

1/ 2"

C L C L

/4

C L C L

3'

/2

C L C L

/4

C L C L

3'

/2

C L 6'

0" C L

C L 3'

/2

"C L 6'

/4

C L

7'

/4

C L C L

3'

/2

C L C L

1"

6'

/4

C L 7'

/4

C L

9'

/4

C L

2'

/2

C L C L

9'

/4

1"

1'

/4

20' - 0 1/4" 8' - 8" 6' - 6 1/2" 4' - 1 3/4" 15' - 7 1/2" 5' - 4 3/4"

6'

/2

C L

3'

/2 " C L

4'

5'

9'

4'

/4

5'

2'

5'

8'

/2

8'

/4

2' - 9"

CL

3' - 8 1/4"

CLCL

4' - 5 1/2"

CLCL

4' - 5 1/2"

CL

2' - 5"8' - 6 3/4"

2' - 0"

1' - 6"

9' - 0 1/2"9' - 6 1/4"9' - 10 3/4"9' - 2"

8'

/4

CL

8' - 0 3/4"5' - 9 1/2"9' - 10 1/4"7' - 6"3' - 3"

A

A6

A

A

A

N

N

N3

C .f.

A

C.f.6

C .f.

C .f.

C.f.6

C.f.6

N

A4

C .f.

C6

A

B6

C

C.f.6

N

A

N

A6 A6 A6

A

A6

A

A6

A6

A6 A6

A

CL

4' - 7 1/4"

W1R

W1R

W1R

W1L

W1L

W1R W1R W1L

W1L W1L

W2 W2 W2

AS502

i112B

DINING

i102

W5

W5

W5

W5

W5

W5

W8 W8W8

W5

W8

W8

W8

30' - 4 1/2"

W8

W8

A6

C L

E Q

C L C L

6'

C L C L

6'

C L

E Q

/4

/2

W8 W8 W8

CL

4' - 2 1/2"

CL

5' - 3 1/2"

CL

7' - 7 1/2"

CLCL

3' - 10"

CLCL

3' - 10"

CLCL

3' - 10"

CL

1' - 11"

C L 3'

C L

C L 4'

/2

C L

3'

/2

10" 10"

4 EQUAL PANELS

10' - 11 1/4"

4 EQUAL PANELS

10' - 11 1/4" EQ

3"

EQ

C L

2'

/2 " C L

6'

/4

WP-1

WP-1

WP-1

W P

-1

WP-1WP-1

WP-1 WP-1

W P

-1

W P

-1

W P

-1

W P

-1

W P

-1

WP-1

W P

-1

W P

-1

WP-1 WP-1

W P

-1

W P

-1 W

P -1

W P

-1 W

P -1

SHIPS LADDER UP

UP TO ATTIC

CL

7' - 3"

CL

5' - 0"

WP-1

CG

CG

CG CG

CG

CGCG CG

CG

CG

CG

CG

FEC

FEC

FEC

FEC

FEC

FEC

17' - 0"

3'

1/ 4"

5'

/4 i1 i1

B i1

C

BEDROOM

i105

CLOSET

i105B

BATHROOM

i105C

RESIDENT LIFT

ABOVE

AS322

AS321

A6

B

C4

C

C4

A

2' - 2 1/2"

1'

CL

10 3/4"

CLOSET SHELF AND

ROD AT 68" A.F.F.

CL

5' - 0 3/4"4' - 9 1/2"

CL

1' - 5 3/4"

CL

1' - 5 3/4"

CL

2' - 0 1/4"

5"

AS621 8

AS622 1 SIM

SIM

MEDICINE CABINET

UPSWING GRAB

BARS - SEE DETAILS

SHOWER CURTAIN ROD

- SEE SPECS.

S H

O W

E R

U N

IT

CL

2' - 2"

TOWEL BAR

WALL-MOUNTED SHOWER

SEAT

BARIATRIC BEDROOM

i114

BATHROOM

i114C

CLOSET

i114B i114B i114C i114

13' - 3" 3' - 11 1/4" 5' - 3 1/4"

22' - 5 1/2"

RESIDENT LIFT ABOVE

AS321

AS321

AS323

C4

C

C

A6

A

A

AS622

AS621

MEDICINE

CABINET

CLOSET SHELF

AND ROD AT 68"

A.F.F.

7'

C L 1'

/4

C L

1'

/4

C L 2'

/4

C L

4'

/2

UP-SWING GRAB

BARS - SEE DETAILS

SHOWER UNIT

SHOWER CURTAIN

ROD - SEE SPEC.

CL

1' - 4"

C

C L

3'

TOWEL BAR

WALL-MOUNTED

SHOWER SEAT

GENERAL PLAN NOTES:

A. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND

CONDITIONS PRIOR TO COMMENCING WITH WORK, AND SHALL

PROMPTLY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR

CONFLICTS BETWEEN THE DRAWINS AND ACTUAL CONDITIONS

ENCOUNTERED IN THE FIELD.

B. ALL WORK SHALL BE PERFORMED IN COMPLIANCE WITH ALL

APPLICABLE CODES, RULES, AND REGULATIONS.

C. DO NOT SCALE DRAWINGS.

D. NOTES ON DRAWINGS SHALL APPLY TO ALL SIMILAR

CONDITIONS WHETHER THEY ARE REPEATED OR NOT.

E. ALL STRUCTURAL MEMBERS, WALLS, PARTITIONS, FLOORS, AND

ROOF ASSEMBLIES SHALL BE PROTECTED WITH APPROVED

FIRE-RATED SYSTEMS WHERE REQUIRED BY APPLICABLE

CODES, RULES, AND REGULATIONS.

F. SEE LIFE SAFETY SHEET FOR LOCATIONS AND RATINGS OF FIRE

BARRIERS, SMOKE BARRIERS, AND SMOKE PARTITIONS.

G. THE CONTRACTOR IS TO ENSURE THAT ALL FIRE-RESISTIVE

RATINGS ARE MAINTAINED PER LOCATIONS IDENTIFIED AND AS

REQUIRED BY APPLICABLE CODES. ALL PENETRATIONS

THROUGH FIRE RATED ASSEMBLIES ARE TO BE SEALED BY AN

APPROVED U.L. FIRE-STOPPING SYSTEM.

H. THE CONTRACTOR IS TO ENSURE THE CONTINUITY OF

AUTOMATIC SPRINKLER-SYSTEM THROUGHOUT ALL AREAS OF

THE PROJECT AND BE DESIGNED AND INSTALLED IN

ACCORDANCE WITH APPLICABLE CODES.

I. REFER TO ENGINEERING DRAWINGS IN ADDITION TO

ARCHITECTURAL DRAWINGS IN DEFINING THE SCOPE OF WORK.

J. REFER TO SHEET AS002 FOR WALL PARTITION TYPES AND

TYPICAL DETAILS.

K. COORDINATE FINAL LOCATIONS OF FIRE EXTINGUISHER

CABINETS WITH C.O.R.

th re e-qu ar te rs in ch o ne fo ot on e-qu ar te r in ch o ne fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot

B th re e in ch es o ne fo ot

PROJECT PRINCIPAL

PROJECT ARCHITECT

ELECTRICAL ENGINEER

PROJECT MANAGER

MECHANICAL ENGINEER

Use or disclosure of data contained on this sheet is subject to the restriction on the title page of this proposal.

Robinson

Robinson

Fischer

Gobreski

Daller

Danville, IL

Drawing Title

Approved:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

N

Department of Veteran Affairs

LANDSCAPE ARCHITECT

CIVIL ENGINEER

STRUCTURAL ENGINEER

Cyr

Meneley

VanderWoude

PLUMBING ENGINEER Daller

CONSTRUCTION DOCUMENTS 06/21/20171

7/

/2

8:

:0

A

M C

:\U se rs \e ric _s la ug ht er

\D oc um en ts \V

A G re e n

H om es A r c h_ er ic

.s la ug ht er .r vt

AS121

INDEPENDENCE - FIRST FLOOR PLAN

ARTE2017.06.21

VA Danville - Green Homes One Indiana Square, Suite 2100

Indianapolis, IN 46204 United States

P: 317 532 5400 F: 317 532 5499 www.URScorp.com

URS PROJECT NO. 25628011

550-316

1/8" = 1'-0"1 OVERALL FLOOR PLAN ( INDEPENDENCE ) 1/2" = 1'-0"2 TYPICAL BEDROOM PLAN

Living Space Sq. Ft. - 8,726 Garage/Utility Sq. Ft. - 1,665

Total Sq. Ft. - 10,391

1/2" = 1'-0"3 BARIATRIC BEDROOM PLAN

AS322

THERAPY

i116

BEDROOM

i115

BEDROOM

i113

BEDROOM

i112

BEDROOM

i111

BEDROOM

i109

BEDROOM

i108

BEDROOM

i107

BEDROOM

i106

BEDROOM

i105

TOILET

i126

LAUNDRY

i127

OFFICE

i130

ELECTRICAL

i131

SPD

i129

SOILED

i128

PANTRY

i103B

GARAGE

i117

LIVING

i104

DINING

i102

CORRIDOR

i132

VESTIBULE

i101

SCREENED PORCH

i135

STORAGE

i124

UTILITY

i120

STORAGE

i125

BATHROOM

i115C

BATHROOM

i113C

BATHROOM

i112C

BATHROOM

i111C

BATHROOM

i109C

BATHROOM

i108C

BATHROOM

i107C

BATHROOM

i106C

BATHROOM

i105C

CLOSET

i105B

CLOSET

i106B

CLOSET

i107B

CLOSET

i108B

CLOSET

i109B

VESTIBULE

i110

CLOSET

i111B

CLOSET

i112B

CLOSET

i113B

CLOSET

i115B

PATIO

i136

PORCH

CLOSET

i101B

KITCHEN

i103

LINEN

i123

BARIATRIC BEDROOM

i114

BATHROOM

i114C

CLOSET

i114B

CLOSET

i133

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0" 109' - 0"

109' - 0" 109' - 0"109' - 0" 109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

108' - 0"

109' - 0" 109' - 0"

109' - 0"

109' - 0" 109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0" 109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

112' - 0" 109' - 0"

112' - 0"

116' - 8"

109' - 0"

SLOPE UP

AS321

AS322

AS322

AS323

AS323

AS321

AS321

AS321

DATA

i121

SPA

i122

HSKP

i118

O2 i119

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

108' - 0"

109' - 0"

109' - 0"

AS122

AS122

AS502

108' - 0"

109' - 0"

109' - 0"

108' - 10"108' - 10"

FIBER-REINFORCED CEMENTITIOUS

SOFFIT PANEL SYSTEM

FIBER-REINFORCED CEMENTITIOUS

NON-VENTED SOFFIT

WOOD TRUSS FRAMING - SEE

STRUCTURAL DWGS.

24"x36" ACCESS DOOR

WOOD TRUSS FRAMING - SEE

STRUCTURAL DWGS.

SOFFIT PANEL JOINT

EQEQ

ALIGN

E Q

E Q

ALIGN

2'

CENTER PANEL JOINT ON

CENTER OF COLUMN/TRUSS

FIBER-REINFORCED CEMTITIOUS

SOFFIT PANEL SYSTEM

FIBER-REINFORCED CEMENTITIOUS

NON-VENTED SOFFIT

AREA TO RECEIVE METAL DECKING AND

CONCRETE SLAB ABOVE FINISHED CEILING -

SEE STRUCTURAL DWGS.

WOOD TRUSS FRAMING - SEE

STRUCTURAL DWGS.

FIBER-REINFORCED CEMENTITIOUS

SOFFIT PANEL SYSTEM

SOFFIT PANEL JOINT

SOFFIT PANEL JOINT

4' - 1"8' - 0"E Q4' - 0"8' - 0"

8'

3'

EQ EQ

7' - 6"

E Q

E Q

7'

11' - 1 1/2" 6' - 0" 3' - 6"

6'

3'

3' - 9" 10' - 0" 6' - 8"

5'

/4

1' - 3 3/4"

4'

0"

9'

EQ EQ

3'

3' - 2"

5'

E Q

E Q

9' - 0" 9' - 0"EQ EQ2'

4' - 2"3' - 8" 4' - 4"

3'

3'

3'

3'

2'

7'

7'

7'

7'

8' - 0"8' - 0"

3' - 6"EQ EQ

4'

/2

3' - 6"EQ EQ

4'

/4

8"

EQ 9' - 0" EQ

109' - 0"

OPEN

OPEN

2' - 1 1/2"

3'

SHIPS LADDER

ACCESS TO ATTIC

3' - 6"

AS122

108' - 6"

7' - 0"

6'

6'

6'

7' - 0 3/4"7' - 0 3/4" 8' - 0"8' - 0"8' - 0"8' - 0"

E Q

EQ EQ

7'

7'

7'

7' - 6" 7' - 6" 7' - 0" 4' - 3"

AS322

AS321

BEDROOM

i105

BATHROOM

i105C

CLOSET

i105B

109' - 0"

109' - 0"

109' - 0"

8"

E Q

U A

L E

Q U

A L

EQUALEQUAL

10' - 0" 3' - 8"

2'

6'

7'

1' - 6"

3' - 2"

3'

2' - 10"

AS122

TURNTABLE BY RESIDENT

LIFT MANUFACTURER

CENTER PATIENT LIFT

TRACK ON TOILET

RESIDENT LIFT SYSTEM, SEE STRUCTURAL

DWGS. FOR ADDITIONAL INFORMATION, ALIGN

WITH CENTER OF BATHROOM DOOR.

COORDINATE WITH ALL DUCTWORK, CEILING

PENETRATIONS, EQUIPMENT, PIPING AND

LIGHTING..

1'

5'

2'

TRACK LOCATION TO BE

APPROVED BY C.O.R.

AS321

AS323

BARIATRIC BEDROOM

i114

CLOSET

i114B

BATHROOM

i114C

109' - 0"

109' - 0"

109' - 0"

RESIDENT LIFT SYSTEM, SEE STRUCTURAL DWGS.

FOR ADDITIONAL INFORMATION, ALIGN WITH

CENTER OF BATHROOM DOOR. COORDINATE

WITH ALL DUCTWORK, CEILING PENETRATIONS,

EQUIPMENT, PIPING AND LIGHTING.

2' - 0"

8" 2'

0"

EQUAL EQUAL

E Q

U A

L E

Q U

A L

CL

2' - 7 1/4"

CL

8' - 0" 8' - 0"

3'

1'

3' - 6"

3'

AS122

TURNTABLE BY RESIDENT LIFT

MANUFACTURER

CENTER PATIENT LIFT

TRACK ON TOILET

1'

7' - 6"

TRACK LOCATION TO BE

APPROVED BY C.O.R.

GENERAL CEILING PLAN NOTES:

A. REFER TO ENGINEERING DRAWINGS FOR SPECIFIC EQUIPMENT

INFORMATION AND REQUIREMENTS. CONTRACTOR TO REFER

ANY DISCREPANCIES TO DESIGN TEAM FOR REVIEW.

B. REFER TO ROOM FINISH SCHEDULE FOR CEILING TYPES AND

LOCATIONS. ACOUSTIC PANEL CEILINGS ARE TO BE CENTERED

WITHIN THE ROOM UNLESS NOTED OTHERWISE.

C. ALL CEILINGS ARE TO BE 9'-0" U.N.O.

D. MAINTAINING WALL TO WALL CONTINUITY OF THE RATED

CEILING ASSEMBLY IS REQUIRED. CEILINGS TO BE

CONSTRUCTED OF (2) LAYERS OF 1/2" TYPE C GYPSUM BOARD

AS NOTED IN UL L542.

E. FOR NON-RATED GYPSUM BOARD FINISH CEILINGS BELOW THE

FIRE RESISTIVE LEVEL, CONTRACTOR HAS THE OPTION OF USE

OF EITHER A SUSPENDED GYPSUM SYSTEM OR FRAMED WITH

INTERMEDIATE FRAMING AND APPLIED WITH GYPSUM BOARD.

F. FINAL EXIT SIGN REQUIREMENTS ARE SUBJECT TO APPROVAL

BY LOCAL AUTHORITY HAVING JURISDICTION.

G. COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS

FOR ADDITIONAL CEILING ACCESS POINTS WHICH MAY BE

REQUIRED AT AREAS FOR MECHANICAL AND/OR ELECTRICAL

SERVICE.

H. ALL EXPOSED STRUCTURE, DUCTWORK, PIPING, AND CONDUIT

SHALL BE PAINTED IN AREAS WITHOUT FINISHED CEILINGS ON

THE FIRST FLOOR. COLOR TO BE SELECTED BY ARCHITECT.

I. REFER TO ENLARGED BEDROOM PLANS FOR CEILING FIXTURE

LOCATIONS.

J. REFER TO FIRE PROTECTION DRAWINGS FOR SPRINKLER HEAD

LOCATIONS AND REQUIREMENTS.

K. CENTER ALL ACOUSTIC PANEL CEILING GRIDS IN ROOMS

UNLESS NOTED OTHERWISE.

CEILING PLAN LEGEND

AIR DIFFUSER

RETURN AIR

GYPSUM BOARD CEILING / BULKHEAD

SURFACE MOUNTED FLUORESCENT

LUMINAIRE

RECESSED CAN LIGHT

PENDANT LIGHT

ACT-2 ACOUSTICAL LAY-IN CEILING

ACT-1 CLEANABLE LAY-IN CEILING

LINEAR PENDANT LUMINAIRE

CEILING FAN

GYPSUM BOARD CEILING AT CONCRET DECK WITH

WOOD FURRING

RECESSED FLOURESCENT LUMINAIRE

UNISTRUT FRAMING ANCHORED TO TRUSS

FRAMING AS REQUIRED FOR SUPPORT

ROOF TRUSS FRAMING - SEE

STRUCTURAL DWGS.

THREADED ROD, HEX NUT, AND WASHER

CEILING BRACKET AND PATIENT LIFT

TRACK

CEILING FINISH AS SCHEDULED

PATIENT LIFT UNIT - SEE

SPECIFICATIONS

109' - 0"

SPA

i122

12' - 0"

1' - 4" 8" 2' - 6"

7'

RESIDENT LIFT SYSTEM, SEE STRUCTURAL

DWGS. FOR ADDITIONAL INFORMATION;

ALIGN WITH CENTER OF TOILET

PRIVACY CURTAIN TRACK, SPLICE

TRACK AT PATIENT LIFT SYSTEM

1' - 0" th re e-qu ar te rs in ch o ne fo ot on e-qu ar te r in ch o ne fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot

B th re e in ch es o ne fo ot

PROJECT PRINCIPAL

PROJECT ARCHITECT

ELECTRICAL ENGINEER

PROJECT MANAGER

MECHANICAL ENGINEER

Use or disclosure of data contained on this sheet is subject to the restriction on the title page of this proposal.

Robinson

Robinson

Fischer

Gobreski

Daller

Danville, IL

Drawing Title

Approved:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veteran Affairs

LANDSCAPE ARCHITECT

CIVIL ENGINEER

STRUCTURAL ENGINEER

Cyr

Meneley

VanderWoude

PLUMBING ENGINEER Daller

CONSTRUCTION DOCUMENTS 06/21/20171

7/

/2

3:

:5

P

M C

:\U se rs \e ric _s la ug ht er

\D oc um en ts \V

A G re e n

H om es A r c h_ er ic

.s la ug ht er .r vt

AS122

INDEPENDENCE - REFLECTED CEILING PLAN

ARTE2017.06.21

VA Danville - Green Homes One Indiana Square, Suite 2100

Indianapolis, IN 46204 United States

P: 317 532 5400 F: 317 532 5499 www.URScorp.com

URS PROJECT NO. 25628011

550-316

AS322

AS321

ATTIC

i201

AS322

AS322

AS323

AS323

AS321

AS321

AS321

AS502

30x48 ACCESS HATCH

PLYWOOD ATTIC WALKWAY - SEE

STRUCTURAL DWGS. FOR LOCATION

OPEN

TO BELOW

6' - 0"16' - 0 3/4" 5' - 3 3/4" 3' - 6"

7'

1/2" PLYWOOD OVER 2x

WOOD CONSTRUCTION

TO STRUCTURE ABOVE

CASED WALL OPENING FOR

ATTIC ACCESS

SHIPS LADDER BELOW

O

P E

N T

O B

E

LO

W

AREA TO RECEIVE METAL DECKING

AND CONCRETE SLAB ABOVE

FINISHED CEILING - SEE STRUCTURAL

DWGS.

60"x80" UNEVEN DOOR

FOR ATTIC ACCESS

1'

HOIST MOUNTING HOOK,

COORDINATE W/ STRUCTURAL

DWGS.

REMOVABLE GUARD RAIL

i201

GENERAL PLAN NOTES:

A. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND

CONDITIONS PRIOR TO COMMENCING WITH WORK, AND SHALL

PROMPTLY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR

CONFLICTS BETWEEN THE DRAWINS AND ACTUAL CONDITIONS

ENCOUNTERED IN THE FIELD.

B. ALL WORK SHALL BE PERFORMED IN COMPLIANCE WITH ALL

APPLICABLE CODES, RULES, AND REGULATIONS.

C. DO NOT SCALE DRAWINGS.

D. NOTES ON DRAWINGS SHALL APPLY TO ALL SIMILAR

CONDITIONS WHETHER THEY ARE REPEATED OR NOT.

E. ALL STRUCTURAL MEMBERS, WALLS, PARTITIONS, FLOORS, AND

ROOF ASSEMBLIES SHALL BE PROTECTED WITH APPROVED

FIRE-RATED SYSTEMS WHERE REQUIRED BY APPLICABLE

CODES, RULES, AND REGULATIONS.

F. SEE LIFE SAFETY SHEET FOR LOCATIONS AND RATINGS OF FIRE

BARRIERS, SMOKE BARRIERS, AND SMOKE PARTITIONS.

G. THE CONTRACTOR IS TO ENSURE THAT ALL FIRE-RESISTIVE

RATINGS ARE MAINTAINED PER LOCATIONS IDENTIFIED AND AS

REQUIRED BY APPLICABLE CODES. ALL PENETRATIONS

THROUGH FIRE RATED ASSEMBLIES ARE TO BE SEALED BY AN

APPROVED U.L. FIRE-STOPPING SYSTEM.

H. THE CONTRACTOR IS TO ENSURE THE CONTINUITY OF

AUTOMATIC SPRINKLER-SYSTEM THROUGHOUT ALL AREAS OF

THE PROJECT AND BE DESIGNED AND INSTALLED IN

ACCORDANCE WITH APPLICABLE CODES.

I. REFER TO ENGINEERING DRAWINGS IN ADDITION TO

ARCHITECTURAL DRAWINGS IN DEFINING THE SCOPE OF WORK.

J. REFER TO SHEET AS002 FOR WALL PARTITION TYPES AND

TYPICAL DETAILS.

K. COORDINATE FINAL LOCATIONS OF FIRE EXTINGUISHER

CABINETS WITH C.O.R.

GENERAL ATTIC PLAN NOTES:

A. REFER TO ENGINEERING DRAWINGS FOR SPECIFIC EQUIPMENT

INFORMATION AND REQUIREMENTS. CONTRACTOR TO REFER

ANY DISCREPANCIES TO DESIGN TEAM FOR REVIEW.

B. COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS

FOR ADDITIONAL CEILING ACCESS POINTS WHICH MAY BE

REQUIRED AT AREAS FOR MECHANICAL AND/OR ELECTRICAL

SERVICE.

C. COORDINATE FINAL LOCATIONS AND DIMENSIONS OF PLYWOOD

ACCESS WALKWAYS WITH STRUCTURAL DRAWINGS AND

LOCATION OF MECHANICAL EQUIPMENT LOCATED IN THE ATTIC.

6' - 8"

3'

1 1/2" PIPE RAILING; WELD & GRIND SMOOTH

AND PAINT SAFETY YELLOW

EQUAL EQUAL

PIPE SLEEVE ANCHORED TO FLOOR

DECKING AND WALL FRAMING BELOW

ATTIC FLOOR CONSTRUCTION

5'

/4

1' - 6"

TYP.

10"

ANCHOR SHIPS LADDER

TOCONCRETE FLOOR SLAB WITH

CLEAT AND EXPANSION BOLT

PIPE RAILING AT OPEN SIDE OF

SHIPS LADDER

3'

STEEL CHANNEL STRINGER

1 1/4" x 1 1/4" x 1/4" STEEL ANGLES

AT STAIR TREADS

REINFORCED STAIR TREAD

CONTINUOUS 3x4x1/4 STEEL ANGLE

W/ ANCHORS AT 2'-0" O.C.

PLYWOOD ATTIC WALKWAY OVER TRUSS

FRAMING - SEE STRUCTURAL DWGS.

2x WALL CONSTRUCTION BELOW

6" 6" MASONRY WALL PARTITION AS

SCHEDULED

INSULATED PIPE OR DUCT

FIRESTOPPING MATERIAL

2x WALL PARTITION AS

SCHEDULED

APPROVED FIRESTOPPING INSULATION

WITH VAPOR BARRIER

1"6"

INSULATED PIPE OR DUCT

PIPE SLEEVE WHERE

REQUIRED

FIRESTOPPING MATERIAL

APPROVED FIRESTOPPING

INSULATION WITH VAPOR BARRIER

FLOOR CONSTRUCTION AS

SCHEDULED

th re e-qu ar te rs in ch o ne fo ot on e-qu ar te r in ch o ne fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot

B th re e in ch es o ne fo ot

PROJECT PRINCIPAL

PROJECT ARCHITECT

ELECTRICAL ENGINEER

PROJECT MANAGER

MECHANICAL ENGINEER

Use or disclosure of data contained on this sheet is subject to the restriction on the title page of this proposal.

Robinson

Robinson

Fischer

Gobreski

Daller

Danville, IL

Drawing Title

Approved:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veteran Affairs

LANDSCAPE ARCHITECT

CIVIL ENGINEER

STRUCTURAL ENGINEER

Cyr

Meneley

VanderWoude

PLUMBING ENGINEER Daller

CONSTRUCTION DOCUMENTS 06/21/20171

7/

/2

8:

:1

A

M C

:\U se rs \e ric _s la ug ht er

\D oc um en ts \V

A G re e n

H om es A r c h_ er ic

.s la ug ht er .r vt

AS123

INDEPENDENCE - ATTIC FLOOR PLAN

ARTE2017.06.21

VA Danville - Green Homes One Indiana Square, Suite 2100

Indianapolis, IN 46204 United States

P: 317 532 5400 F: 317 532 5499 www.URScorp.com

URS PROJECT NO. 25628011

550-316

AS123 Scale: 1/8" = 1'-0"

1 ATTIC LEVEL ( INDEPENDENCE )

AS123 Scale: 3/4" = 1'-0"

2 DETAIL @ REMOVABLE RAILING DETAIL

AS123 Scale: 3/4" = 1'-0"

3 DETAIL @ SHIPS LADDER

AS123 Scale: 1" = 1'-0"

4 PIPE / DUCT PENTRATION @ SMOKE OR FIRE BARRIER

AS222 2

AS221

AS2221

AS221

AS322

AS321

4"/12"4"/12"

4"/12"

4"/12"

4"/12"

4"/12"

4"/12"

4"/12"

4"/12"

6"/12" 6"/12"

4"/12"4"/12"

4"/12"

6"/12" 6"/12"

6"/12"

4"/12"

6"/12"

4"/12"

4"/12"

4"/12"

4"/12"

6"/12"

6"/12"

4"/12"4"/12"1

AS322

AS322

AS323

AS323

AS321

AS321

AS321

AS502

F5

F7

F5

F1

F1

F1

F1

F8

F7

F5

F5

F5

F7

F5

F7

F5

F7

F5

F7F7

F8

F8

F7

F7

F5

F7

F5

F7

F1

F9

4' - 0" 7' - 2"

GENERAL ROOF PLAN NOTES:

A. REFER TO ENGINEERING DRAWINGS FOR SPECIFIC EQUIPMENT INFORMATION

AND REQUIREMENTS. CONTRACTOR TO REFER ANY DISCREPANCIES TO

DESIGN TEAM FOR REVIEW.

B. DO NOT SCALE DRAWINGS.

C. REFER TO SECTION AND DETAIL DRAWINGS FOR ADDITIONAL INFORMATION.

D. ALL ROOFING TERMINATIONS AND FLASHING CONDITIONS SHALL CONFORM

WITH MANUFACTURER STANDARDS AND RECOMMENDED DETAILS.

E. NOTES ON THE DRAWINGS SHALL APPLY TO ALL SIMILAR CONDITIONS WHETHER

THEY ARE REPEATED OR NOT.

th re e-qu ar te rs in ch o ne fo ot on e-qu ar te r in ch o ne fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot

B th re e in ch es o ne fo ot

PROJECT PRINCIPAL

PROJECT ARCHITECT

ELECTRICAL ENGINEER

PROJECT MANAGER

MECHANICAL ENGINEER

Use or disclosure of data contained on this sheet is subject to the restriction on the title page of this proposal.

Robinson

Robinson

Fischer

Gobreski

Daller

Danville, IL

Drawing Title

Approved:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

N

Department of Veteran Affairs

LANDSCAPE ARCHITECT

CIVIL ENGINEER

STRUCTURAL ENGINEER

Cyr

Meneley

VanderWoude

PLUMBING ENGINEER Daller

CONSTRUCTION DOCUMENTS 06/21/20171

7/

/2

8:

:1

A

M C

:\U se rs \e ric _s la ug ht er

\D oc um en ts \V

A G re e n

H om es A r c h_ er ic

.s la ug ht er .r vt

AS124

INDEPENDENCE - ROOF PLAN

ARTE2017.06.21

VA Danville - Green Homes One Indiana Square, Suite 2100

Indianapolis, IN 46204 United States

P: 317 532 5400 F: 317 532 5499 www.URScorp.com

URS PROJECT NO. 25628011

550-316

AS124 Scale: 1/8" = 1'-0"

1 INDEPENDENCE - OVERALL ROOF PLAN

KEYNOTES

F1 ASPHALT SHINGLE ROOFING SYSTEM - SEE WALL SECTIONS FOR ADDITIONAL

ASSEMBLY INFORMATION

F5 FIBER-REINFORCED CEMENTITIOUS FASCIA BOARD

F7 PREFINISHED METAL GUTTER - 6"

F8 PREFINISHED METAL DOWNSPOUT - 4"

F9 CHIMNEY W/ MASONRY VENEER ADHERED TO EXTERIOR SHEATHING

G16

ASPHALT ROOF SHINGLES OVER ROOFING

UNDERLAYMENT

FOAM RIDGE CAP

TREATED 2x WOOD FRAMING WITH

SEALANT AT EACH SIDE, TYPICAL

COMPOSITE NAIL BASE INSULATION

ROOF SHEATHING

RIDGE TAPE PER MANUFACTURER

RECOMMENDATIONS

CONTINUOUS WOOD RIDGE SUPPORT BEAM

AS124 Scale: 1 1/2" = 1'-0"

2 DETAIL @ RIDGE CAP

AS124 Scale: 1 1/2" = 1'-0"

3 DETAIL @ VALLEY

VALLEY FLASHING

DOUBLE TREATED 2x SPLINE, BEVEL

CUT WITH SEALANT AT EACH SIDE, TYPICAL

ASPHALT ROOF SHINGLES OVER ROOFING

UNDERLAYMENT

VALLEY TAPE PER MANUFACTURER

RECOMMENDATIONS

COMPOSITE NAIL BASE INSULATION

ROOF SHEATHING

CONTINUOUS VALLEY SUPPORT FRAMING

FD

FD

FD

FD

FDFDFDFDFD

FD

R E

F

DB

OVREF

F R

Z

D W

FD

FD

AS2321

AS231

AS232 2

AS231

DEN

c116

BEDROOM

c115

BEDROOM

c113

BEDROOM

c112

BEDROOM

c111

BEDROOM

c109

BEDROOM

c108

BEDROOM

c107

BEDROOM

c106

BEDROOM

c105

LIVING

c104

DINING

CORRIDOR

VESTIBULE

c101

SCREENED PORCH

c135

STORAGE

c124

STORAGE

c125

BATHROOM

c115C

BATHROOM

c113C

BATHROOM

c112C

BATHROOM

c111C

BATHROOM

c109C

BATHROOM

c107C

BATHROOM

c106C

BATHROOM

c105C

CLOSET

c105B

CLOSET

c106B

CLOSET

c107B

CLOSET

c109B

VESTIBULE

c110

CLOSET

c111B

CLOSET

c112B

CLOSET

c113B

CLOSET

c115B

PATIO

PORCH

c134 c115C c116 c1 c1 c115 c1 c112C c113C c111C c1

C c1

C c1

C c1

C c123 c1

A c1

A c117B c122 c1 c115B c113B c111B c109Bc107Bc106Bc105B c1

C

CLOSET

c101B c101B

LIVING

c104 c1

LINEN

c123

BARIATRIC BEDROOM

c114

BATHROOM

c114C

CLOSET

c114B c114C c114B c114

CLOSET

c133

CORRIDOR

CORRIDOR

c1

CLOSET

c108B

BATHROOM

c108C

KITCHEN

c103 c1

B c108B c1

C c1

A c112B

ELECTRICAL

c131

PANTRY

c103B

OFFICE

c130

SPD

c129

SOILED

c128

LAUNDRY

c127

TOILET

c126

MECH/PLUMBING

EQUIPMENT. SEE MEP

DRAWINGS.

DATA

c121

HOUSEKEEPING

c118

GARAGE

c117

O2 c119

UTILITY

c120

SPA

c122 c1 c120A c119 c118 c121

54' - 10"

CL

12' - 2 1/2"

CL

12' - 3 1/2"

CL

14' - 11 1/2"

CL

6' - 5 1/2"

3'

/2

/2

C L 5'

C L 4'

C L

3'

4'

/4

C L 4'

/4

2' - 0"

5' - 4 3/4"

CL

7' - 3"

20' - 5 3/4"8' - 2 1/4"17' - 6"

CL

5' - 6 1/2"

CL2' - 7 3/4"CL

6' - 8 3/4"

CL CL

3' - 8 1/2"

CL

7' - 0 3/4"

35' - 5"

CL

6' - 8 3/4"

CL

6' - 8 3/4"

CL CL

3' - 8 1/2"

CL CL

14' - 6 1/2"

CL CL

3' - 8 1/2"

35' - 0" 6' - 11"

CL

7' - 0 3/4"

CL CL

3' - 8 1/2"

CL CL

13' - 9 1/2"

CL CL

3' - 8 1/2"

CL

6' - 8 3/4"

C L C L

3'

C L C L

3'

CL CL

4' - 6"

CL CL

4' - 6"

CLCL

4' - 6"

CL

4' - 6"

AS131

AS131

C.f.6

C.f.6

C.f.6

C.f.6

C.f.6

C .f.

C .f.

C .f.

A

A

CL

2' - 6 1/2"

2' - 0" 8' - 2 3/4"2' - 5"

CL

4' - 5 1/4"

CLCL

4' - 5 1/2"

CLCL

3' - 10"

CLCL

3' - 10"

CLCL

3' - 10"

CL

3' - 4"

6'

/2

C L 4'

C L

3'

/2

5'

9'

4'

/4

5'

2'

5'

8'

/2

8'

/2

A6

A

A6

A6

A

C4

A

A6

A

C .f.

A

A

A6 A6 A6 C.f.6

A

C 6 B6

C6 A4

C.f.6

C .f.

C.f.6

C .f.

A6

A6

A6

CL

4' - 7 1/4"

CL

8' - 0 3/4" 5' - 9 1/2" 9' - 10 1/4" 7' - 6" 3' - 3" c1

C

CL

4' - 11 1/4"

30' - 4 1/2"

AS431

AS432

C L E

Q 6'

C L

E Q

C L C L

6'

" AS432

C L 9'

/4

C L

C L C L

4'

4'

CLCL

9' - 10 3/4" c135B

AS321

AS321

AS321

AS321

AS502

AS323

AS323

AS322

AS322

W1L

W1L

W1L

W1R

W1R

W1R

W2 W2 W2

W5

W5

W5

W5

W5

W5

W8 W8

W8

W8

W8

W8

W8 W8 W8 W8 W8

W1R W1R W1R W1L W1L

C.f.6

A

C .f.

C

.f.

C.f.6

ICE

A6

A4

O.H. O.H. O.H. O.H.

O.H.

O.H.

O.H.

O.H.

c1 c1 c1

B c111 c112 c113 c1

A c128 c129 c127 c1 c1 c132B c1

B

1' - 4 1/4"

CL

7' - 3"

CL

1' - 10 1/2"

CL

7' - 0 1/2" 10' - 2 3/4" 8' - 8 1/2"

N

N

A6

N

N3

N3 c1

A

1/ 2"

/2

/4

/2

E

Q . P

A N

E

LS

6'

1/ 2"

E

Q . P

A N

E

LS

6'

1/ 4"

E

Q . P

A N

E

LS

6'

1/ 2"

7'

/2

/2

3'

/2

6'

1/ 2"

/4

3'

/2

/4

3'

/2

6'

0"

3'

/2

6'

/4

7'

/4

3'

/2

C L

9'

/4

C L

2'

/2

C L C L

9'

/4

1"

1'

/4

O.H.

CL

4' - 2 1/2"

CL

5' - 3 1/2" 10"

4 EQUAL PANELS

10' - 11 1/4" 3"

5' - 0"

EQ

4 EQUAL PANELS

10' - 11 1/4" 10"

EQ

3'

C L

4'

C L

3'

/2

W8

4' - 0"

89' - 2 1/2"

2' - 9"

C L

6'

/4

C L

4'

1/ 2"

3'

/2

C L

6'

/2

C L

7'

/4

WP-1 WP-1

WP-1

WP-1WP-1WP-1

WP-1 WP-1 WP-1 WP-1

W P

-1 W

P -1

W P

-1

W P

-1 W

P -1

W P

-1 W

P -1

W P

-1 W

P -1

W P

-1

CG

CG

CG

CG

CG

CG

CG CG

CG

CG

CG

CG

FEC

FEC

FEC

FEC

FEC

FEC

BEDROOM

c105

BATHROOM

c105C

CLOSET

c105B c1 c1

C c1

B

CL

5' - 0 3/4"

CL

2' - 0 1/4"

CL

1' - 5 3/4"

CL

1' - 9 1/4" 4' - 6" 2' - 2 1/2"

17' - 0"

3'

/4

5'

/4

AS6221SIM

SIM

CLOSET SHELF

AND ROD @ 68"

A.F.F.

MEDICINE CABINET

5"

1'

AS6218O.H. 9 O.H.

O.H.

O.H.

RESIDENT LIFT ABOVE

A6

B

C4

C

C4

C

S H

O W

E R

U N

IT

UPSWING GRAB BARS

- SEE DETAILS

SHOWER CURTAIN ROD

- SEE SPECS

CL

2' - 2"

TOWEL BAR

WALL-MOUNTED SHOWER

SEAT

c114C c114B c114 c1

BARIATRIC BEDROOM

c114

BATHROOM

c114C

CLOSET

c114B

CLOSET

c133

C L

4'

1/ 4"

C L

1'

0"

C L

1'

/4

C L

1'

/4

7'

/4

13' - 3"3' - 7 3/4"5' - 6 3/4"

22' - 5 1/2"

AS621

O.H.

O.H.

7 O.H.10O.H.

MEDICINE CABINET

CL

1' - 4"

3'

/2

AS622

O.H.

2O.H.

A6

C .f.

6C4

C4

C

C

A

CLOSET SHELF AND

ROD AT 68" A.F.F.

SHOWER UNIT

SWING UP GRAB

BARS - SEE DETAILS

C

SHOWER CURTAIN

ROD - SEE SPECS

TOWEL BAR

WALL-MOUNTED

SHOWER SEAT

RESIDENT LIFT ABOVE

GENERAL PLAN NOTES:

A. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND

CONDITIONS PRIOR TO COMMENCING WITH WORK, AND SHALL

PROMPTLY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR

CONFLICTS BETWEEN THE DRAWINS AND ACTUAL CONDITIONS

ENCOUNTERED IN THE FIELD.

B. ALL WORK SHALL BE PERFORMED IN COMPLIANCE WITH ALL

APPLICABLE CODES, RULES, AND REGULATIONS.

C. DO NOT SCALE DRAWINGS.

D. NOTES ON DRAWINGS SHALL APPLY TO ALL SIMILAR

CONDITIONS WHETHER THEY ARE REPEATED OR NOT.

E. ALL STRUCTURAL MEMBERS, WALLS, PARTITIONS, FLOORS, AND

ROOF ASSEMBLIES SHALL BE PROTECTED WITH APPROVED

FIRE-RATED SYSTEMS WHERE REQUIRED BY APPLICABLE

CODES, RULES, AND REGULATIONS.

F. SEE LIFE SAFETY SHEET FOR LOCATIONS AND RATINGS OF FIRE

BARRIERS, SMOKE BARRIERS, AND SMOKE PARTITIONS.

G. THE CONTRACTOR IS TO ENSURE THAT ALL FIRE-RESISTIVE

RATINGS ARE MAINTAINED PER LOCATIONS IDENTIFIED AND AS

REQUIRED BY APPLICABLE CODES. ALL PENETRATIONS

THROUGH FIRE RATED ASSEMBLIES ARE TO BE SEALED BY AN

APPROVED U.L. FIRE-STOPPING SYSTEM.

H. THE CONTRACTOR IS TO ENSURE THE CONTINUITY OF

AUTOMATIC SPRINKLER-SYSTEM THROUGHOUT ALL AREAS OF

THE PROJECT AND BE DESIGNED AND INSTALLED IN

ACCORDANCE WITH APPLICABLE CODES.

I. REFER TO ENGINEERING DRAWINGS IN ADDITION TO

ARCHITECTURAL DRAWINGS IN DEFINING THE SCOPE OF WORK.

J. REFER TO SHEET AS002 FOR WALL PARTITION TYPES AND

TYPICAL DETAILS.

K. COORDINATE FINAL LOCATIONS OF FIRE EXTINGUISHER

CABINETS WITH C.O.R.

th re e-qu ar te rs in ch o ne fo ot on e-qu ar te r in ch o ne fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot

B th re e in ch es o ne fo ot

PROJECT PRINCIPAL

PROJECT ARCHITECT

ELECTRICAL ENGINEER

PROJECT MANAGER

MECHANICAL ENGINEER

Use or disclosure of data contained on this sheet is subject to the restriction on the title page of this proposal.

Robinson

Robinson

Fischer

Gobreski

Daller

Danville, IL

Drawing Title

Approved:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

N

Department of Veteran Affairs

LANDSCAPE ARCHITECT

CIVIL ENGINEER

STRUCTURAL ENGINEER

Cyr

Meneley

VanderWoude

PLUMBING ENGINEER Daller

CONSTRUCTION DOCUMENTS 06/21/20171

7/

/2

8:

:2

A

M C

:\U se rs \e ric _s la ug ht er

\D oc um en ts \V

A G re e n

H om es A r c h_ er ic

.s la ug ht er .r vt

AS131

COURAGE - FIRST FLOOR PLAN

ARTE2017.06.21

VA Danville - Green Homes One Indiana Square, Suite 2100

Indianapolis, IN 46204 United States

P: 317 532 5400 F: 317 532 5499 www.URScorp.com

URS PROJECT NO. 25628011

550-316

Living Space Sq. Ft. - 8,726 Garage/Utility Sq. Ft. - 1,665

Total Sq. Ft. - 10,391 AS131 Scale: 1/8" = 1'-0"

1 OVERALL FLOOR PLAN ( COURAGE )

AS131 Scale: 1/2" = 1'-0"

2 ENLARGED FP - TYP BEDROOM ( COURAGE )

AS131 Scale: 1/2" = 1'-0"

3 ENLARGED FP - BARIATRIC ( COURAGE )

DEN

c116

BEDROOM

c115

BEDROOM

c113

BEDROOM

c112

BEDROOM

c111

BEDROOM

c109

BEDROOM

c108

BEDROOM

c107

BEDROOM

c106

BEDROOM

c105

OFFICE

c130

SPD

c129

TOILET

c126

ELECTRICAL

c131

SOILED

c128

LAUNDRY

c127

PANTRY

c103B

GARAGE

c117

LIVING

c104

DINING

CORRIDOR

VESTIBULE

c101

SCREENED PORCH

c135

STORAGE

c124

SPA

c122

UTILITY

c120

STORAGE

c125

BATHROOM

c115C

BATHROOM

c113C

BATHROOM

c112C

BATHROOM

c111C

BATHROOM

c109C

BATHROOM

c108CBATHROOM c107C

BATHROOM

c106C

BATHROOM

c105C

HOUSEKEEPING

c118

CLOSET

c105B

CLOSET

c106B

CLOSET

c107B

CLOSET

c108B

CLOSET

c109B

VESTIBULE

c110

CLOSET

c111B

CLOSET

c112B

CLOSET

c113B

CLOSET

c115B

PATIO

PORCH

c134

O2 c119

CLOSET

c101B

KITCHEN

c103

LINEN

c123

BARIATRIC BEDROOM

c114

BATHROOM

c114C

CLOSET

c114B

CLOSET

c133

DATA

c121

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0" 109' - 0" 109' - 0"

109' - 0" 109' - 0" 109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0" 109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0" 109' - 0" 109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0" 109' - 0"

109' - 0"

112' - 0"

109' - 0"

116' - 8"

109' - 0"

AS132

AS132

3109' - 0"

AS322

AS322

AS322

AS323

O.H.

O.H.

O.H.

O.H.

AS502

O.H.

AS323

O.H.

AS321

O.H.

AS321

AS321

O.H.O.H.

109' - 0"

109' - 0"

108' - 10"

109' - 0"

SLOPE UP

FIBER-REINFORCED CEMENTITIOUS

SOFFIT PANEL SYSTEM

FIBER-REINFORCED CEMENTITIOUS

NON-VENTED SOFFIT

24"x36" ACCESS DOOR

WOOD TRUSS FRAMING - SEE

STRUCTURAL DWGS.

SOFFIT PANEL JOINT

EQ EQ

ALIGN

E Q

E Q

ALIGN

CENTER PANEL JOINT ON

CENTER OF COLUMN/TRUSS

FIBER-REINFORCED CEMTITIOUS

SOFFIT PANEL SYSTEM

FIBER-REINFORCED CEMENTITIOUS

NON-VENTED SOFFIT

AREA TO RECEIVE METAL DECKING AND

CONCRETE SLAB ABOVE FINISHED CEILING -

SEE STRUCTURAL DWGS.

WOOD TRUSS FRAMING - SEE

STRUCTURAL DWGS.

FIBER-REINFORCED CEMENTITIOUS

SOFFIT PANEL SYSTEM

SOFFIT PANEL JOINT

SOFFIT PANEL JOINT

4' - 1" 8' - 0" E Q 4' - 0" 8' - 0"

8'

3'

EQEQ

7' - 6"E Q

E Q

7'

11' - 1 1/2"6' - 0"

6'

3'

/2

3' - 9"10' - 0"6' - 8"

5'

/2

1' - 4 1/2"

4'

0"

9'

EQEQ

3'

3' - 2"

5'

E Q

E Q

9' - 0"9' - 0" EQEQ 2'

4' - 2" 3' - 8"4' - 4"

3'

3'

3'

3'

2'

7'

7'

7'

7'

8' - 0" 8' - 0"

3' - 6"

3' - 6"

8"

EQ9' - 0"EQ

OPEN

OPEN

2' - 1 1/2"

SHIPS LADDER

ACCESS TO ATTIC

2' - 11"

6'

6'

6'

E Q

EQEQ

7'

7'

7'

4' - 3"

109' - 0"109' - 0"109' - 0"

109' - 0"

109' - 0"

109' - 0"

109' - 0"

7' - 11 1/2" 8' - 0" 8' - 0" 8' - 0 1/2" 7' - 0 1/4" 7' - 1 1/4" 6' - 11 1/2"

7' - 0" 7' - 6" 7' - 6"

2'

1"

EQ EQ

BEDROOM

c105

BATHROOM

c105C

CLOSET

c105B

109' - 0"

109' - 0"

109' - 0"

AS321

1'

E Q

U A

L

EQUAL EQUAL

10' - 0"3' - 8"

2'

6'

1' - 6"

3' - 2"

3'

E Q

U A

L

7'

AS122

1'

5'

2'

RESIDENT LIFT SYSTEM, SEE STRUCTURAL

DWGS. FOR ADDITIONAL INFORMATION,

ALIGN WITH CENTER OF BATHROOM DOOR.

COORDINATE WITH ALL DUCTWORK, CEILING

PENETRATIONS, EQUIPMENT, PIPING AND

LIGHTING.

CENTER PATIENT LIFT TRACK

ON TOILET

TURNTABLE BY RESIDENT

LIFT MANUFACTURER

TRACK LOCATION TO BE

APPROVED BY C.O.R.

BARIATRIC BEDROOM

c114

BATHROOM

c114C

CLOSET

c114B

109' - 0"

109' - 0"

109' - 0"

AS323

7' - 6" 8' - 0" 3' - 1"

3'

E Q

U A

L E

Q U

A L

EQUAL EQUAL

3'

3' - 6"

8" 2'

0"

TURNTABLE BY RESIDENT LIFT

MANUFACTURER

CENTER PATIENT LIFT

TRACK ON TOILET

1'

RESIDENT LIFT SYSTEM, SEE STRUCTURAL DWGS. FOR

ADDITIONAL INFORMATION, ALIGN WITH CENTER OF

BATHROOM DOOR. COORDINATE WITH ALL

DUCTWORK, CEILING PENETRATIONS, EQUIPMENT,

PIPING AND LIGHTING.

2' - 0"7' - 6"

TRACK LOCATION TO BE

APPROVED BY C.O.R.

GENERAL CEILING PLAN NOTES:

A. REFER TO ENGINEERING DRAWINGS FOR SPECIFIC EQUIPMENT

INFORMATION AND REQUIREMENTS. CONTRACTOR TO REFER

ANY DISCREPANCIES TO DESIGN TEAM FOR REVIEW.

B. REFER TO ROOM FINISH SCHEDULE FOR CEILING TYPES AND

LOCATIONS. ACOUSTIC PANEL CEILINGS ARE TO BE CENTERED

WITHIN THE ROOM UNLESS NOTED OTHERWISE.

C. ALL CEILINGS ARE TO BE 9'-0" U.N.O.

D. MAINTAINING WALL TO WALL CONTINUITY OF THE RATED

CEILING ASSEMBLY IS REQUIRED. CEILINGS TO BE

CONSTRUCTED OF (2) LAYERS OF 1/2" TYPE C GYPSUM BOARD

AS NOTED IN UL L542.

E. FOR NON-RATED GYPSUM BOARD FINISH CEILINGS BELOW THE

FIRE RESISTIVE LEVEL, CONTRACTOR HAS THE OPTION OF USE

OF EITHER A SUSPENDED GYPSUM SYSTEM OR FRAMED WITH

INTERMEDIATE FRAMING AND APPLIED WITH GYPSUM BOARD.

F. FINAL EXIT SIGN REQUIREMENTS ARE SUBJECT TO APPROVAL

BY LOCAL AUTHORITY HAVING JURISDICTION.

G. COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS

FOR ADDITIONAL CEILING ACCESS POINTS WHICH MAY BE

REQUIRED AT AREAS FOR MECHANICAL AND/OR ELECTRICAL

SERVICE.

H. ALL EXPOSED STRUCTURE, DUCTWORK, PIPING, AND CONDUIT

SHALL BE PAINTED IN AREAS WITHOUT FINISHED CEILINGS ON

THE FIRST FLOOR. COLOR TO BE SELECTED BY ARCHITECT.

I. REFER TO ENLARGED BEDROOM PLANS FOR CEILING FIXTURE

LOCATIONS.

J. REFER TO FIRE PROTECTION DRAWINGS FOR SPRINKLER HEAD

LOCATIONS AND REQUIREMENTS.

K. CENTER ALL ACOUSTIC PANEL CEILING GRIDS IN ROOMS

UNLESS NOTED OTHERWISE.

CEILING PLAN LEGEND

RECESSED FLUORESCENT LUMINAIRE

AIR DIFFUSER

RETURN AIR

GYPSUM BOARD BULKHEAD

SURFACE MOUNTED FLUORESCENT

LUMINAIRE

RECESSED CAN LIGHT

PENDANT LIGHT

ACT-2 ACOUSTICAL LAY-IN CEILING

ACT-1 CLEANABLE LAY-IN CEILING

LINEAR PENDANT LUMINAIRE

CEILING FAN

th re e-qu ar te rs in ch o ne fo ot on e-qu ar te r in ch o ne fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot

B th re e in ch es o ne fo ot

PROJECT PRINCIPAL

PROJECT ARCHITECT

ELECTRICAL ENGINEER

PROJECT MANAGER

MECHANICAL ENGINEER

Use or disclosure of data contained on this sheet is subject to the restriction on the title page of this proposal.

Robinson

Robinson

Fischer

Gobreski

Daller

Danville, IL

Drawing Title

Approved:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veteran Affairs

LANDSCAPE ARCHITECT

CIVIL ENGINEER

STRUCTURAL ENGINEER

Cyr

Meneley

VanderWoude

PLUMBING ENGINEER Daller

CONSTRUCTION DOCUMENTS 06/21/20171

7/

/2

3:

:0

P

M C

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.