CBB PANEL CIRCUIT.pdf

PDF 131 KB Posted

Attached to
Y1DA--Project 671-18-106, Replace Water Softeners - San Antonio
Solicitation number
36C25722B0024
Issued by

About this file

This document contains a panel circuit trace and information on a related federal contract opportunity. The panel circuit trace provides details on an electrical panelboard for the S&B South Texas Veterans Health facility in San Antonio, including the panel identification, manufacturer, amperage, main disconnect, conductor type, voltage, bus type, and circuit identifications and functions.

The related federal contract opportunity is solicitation number 36C25722B0024 from the Department of Veterans Affairs for project 671-18-106 to replace water softeners at the San Antonio location. The opportunity type is listed as a solicitation.

View the file

Other files

File Type Posted
Amendment 36C25722B0024 0004.docx DOCX document
Answers for 671-18-106 Replace Water Softeners with VA and A.E Responses.pdf PDF
Panel Board PIC IMG_0325.pdf PDF
Panel Board PIC IMG_0320.pdf PDF
Panel Board PIC IMG_0318.pdf PDF
Panel Board PIC IMG_0317.pdf PDF
Panel Board PIC IMG_0319.pdf PDF
Amendment 36C25722B0024 0003.docx DOCX document
Panel Board PIC IMG_0322.pdf PDF
CBA PANEL CIRCUIT.pdf PDF
COA PANEL CIRCUIT.pdf PDF
Panel Board PIC IMG_0323.pdf PDF
Panel Board PIC IMG_0321.pdf PDF
Panel Board PIC IMG_0324.pdf PDF
Amendment 36C25722B0024 0002.docx DOCX document
All 671-18-106 Water Softener Sign-In Walkthrough sheet.pdf PDF
Appendix D - Brine Tank Assessment Report_Redacted.pdf PDF
As Built 1-W2 Main.PDF PDF
Appendix E - Structural Observation Report_Redacted.pdf PDF
As Built Fuel Tank File 2 of 3.pdf PDF
As Built 12-725 Hazardous Storage Pad Sht C01.PDF PDF
Amendment 36C25722B0024 0001.pdf PDF
As Built I-S127.pdf PDF
As Built Fuel Tank File 1 of 3.pdf PDF
671-18-106 Design Analysis Report FINAL_Redacted.pdf PDF
As Built 1-W Warehouse.PDF PDF
Appendix G - GPR Scan Report and Findings_Redacted.pdf PDF
As Built 1-W3 Main.PDF PDF
As Built I-P70.pdf PDF
As Built Fuel Tank File 3 of 3.pdf PDF
As Built I-W12.pdf PDF
As Built 1-W1 Main.PDF PDF
Attachment 671-18-106 Construction Specifications.pdf PDF
OSHA - EMR requirement.pdf PDF
Attachment 671-18-106 Construction Drawings.pdf PDF
Attachment Replace Water Softeners - Requested Structural Drawings.pdf PDF
Addendum to SOW.pdf PDF
VA NOTICE OF LIMITATIONS ON SUBCONTRACTING REQUIREMENT.pdf PDF
SELF-PERFORMED CALCULATIONS.pdf PDF
GA Drawing S5103-202P-(M-GA01)-V112030276-01_4.pdf PDF
Solicitation 36C25722B0024_1.docx DOCX document
Show all 41

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Houston (713) 644-5400 San Antonio/Austin (210) 696-6303

PANELBOARD CIRCUIT TRACE

CUSTOMER: LOCATION: JOB NO.: HOU19-310

S&B SOUTH TEXAS VETERANS HEALTH DATE: 9/2/2020

SAN ANTONIO, TX VERIFIED BY:

JP/JM/MP/AH

PANEL IDENTIFICATION: CBB MFG.: ITE AMPS: 100 MAIN DISCONNECT: Y / N SIZE:

CONDUCTOR/PHASE: 3P/4W VOLTAGE: 208/120 BUS TYPE: C / AL FEED FROM: CBA

CIRCUIT # ID

1 CAPPED OFF 2 CAPPED OFF

3 CAPPED OFF 4 CAPPED OFF

5 CAPPED OFF 6 REC 038

7 REC J002 8 038

9 REC 038 10 MEDICAL AIR M003

11 038 12 MEDICAL AIR M003

13 14

15 16

17 18

19 20

21 22

23 24

25 26

27 28

29 30

31 32

33 34

35 36

37 38

39 40

41 42

REMARKS:

PANELBOARD CIRCUIT TRACE

File details come from the government source that posted it. Updated .