36C25618B0375-008.pdf

PDF 5 MB Posted

Attached to
Project: 586-16-106, 586-18-3-1513-0001 Construction
Solicitation number
36C25618B0375
Issued by

About this file

36C25618B0375 80_EL_VACLC_2018-01-12_IFB.pdf

View the file

Other files

File Type Posted
36C25618B0375-00004000.docx DOCX document
36C25618B0375-00004003.pdf PDF
36C25618B0375-00004005.pdf PDF
36C25618B0375-00004004.pdf PDF
36C25618B0375-00004001.pdf PDF
36C25618B0375-00004006.pdf PDF
36C25618B0375-00004002.pdf PDF
36C25618B0375-00003000.docx DOCX document
36C25618B0375-00002000.docx DOCX document
36C25618B0375-00002001.pdf PDF
36C25618B0375-00001000.docx DOCX document
36C25618B0375-001.docx DOCX document
36C25618B0375-009.pdf PDF
36C25618B0375-010.pdf PDF
36C25618B0375-007.pdf PDF
36C25618B0375-003.pdf PDF
36C25618B0375-004.pdf PDF
36C25618B0375-006.pdf PDF
36C25618B0375-005.pdf PDF
36C25618B0375-002.pdf PDF
36C25618B0375-000.docx DOCX document
Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A B C D E

F G

H

J K M N O P R S T U V W

MCC/MCA

L1E

EDA

T4

LDP

SWBD MSB

L1B

E1A

L1D

L1AL1C

EGS

EGN

EXISTING JOHNSON

CONTROLS PANEL TO

BE RELOCATED

AHU-11

N

PUMP

PUMP

PUMP

PUMP

PUMP

AHU-10

AHU-12

SUPPLY

TERTIARY

PUMP

TERTIARY

PUMP VFD

EX

EX

EX

EX

EX

EX

EX

EX EX

ERL

EX

EXEX

EX

EX EX

EX

EX

EX

EX

EF-6

EX EX

ERL

ERL

ERL

ER ER ER ER ER

ER

EX

EXEX

EX

COMPRESSOR

ER

12 (2) TYP. 12 (2) TYP. 12 (2) TYP.

10 10

ER ERERER

ERL

NCT NCT

ER

ER

ER

ER

1100 Clark Avenue St. Louis, Missouri 63102

T: 314.241.6250 F: 314.241.2570

JACKSON, MS

CANNON DESIGN PROJECT NO. 03640.61

© CannonDesign 2017 - All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation.

JAN 12, 2018

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. of 82Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

COMMUNITY LIVING CENTER

RENOVATION

586-16-106LEVEL 01 ELECTRICAL DEMOLITION

PLAN

D0801 Checker Author

A. REMOVE ALL ELECTRICAL EQUIPMENT ON OR IN EXISTING WALLS, CEILINGS AND PARTITIONS WHICH ARE TO BE DEMOLISHED. REMOVE ALL EXPOSED PORTIONS OF BRANCH CIRCUIT AND CONTROL VOLTAGE WIRING AND CONDUITS.

B. WHERE EXISTING WALLS ARE TO REMAIN, REMOVE ALL EXPOSED RACEWAYS, SURFACE AND RECESSED OUTLET BOXES, ETC. WHICH ARE NOT TO BE REUSED. WHERE NEW CONDUITS AND OUTLETS ARE TO BE ADDED TO EXISTING WALLS IN

FINISHED ROOMS, THEY SHALL BE CONCEALED BY CUTTING AND PATCHING THE WALLS.

C. UTILIZE EXISTING OUTLET BOXES AND RACEWAY SYSTEMS WHEREVER PRACTICAL IN RENOVATION AREAS. WHERE SUCH EXISTING OUTLET BOXES ARE USED, INSTALL NEW WIRING DEVICES, COVERPLATES, AND WIRING. SPECIAL

COVERPLATES MAY BE REQUIRED TO SUIT CONDITIONS.

D. REARRANGE EXISTING CONDUITS AND WIRING TO ACCOMMODATE NEW CIRCUIT ARRANGEMENTS INDICATED AND TO

MAINTAIN CONTINUITY OF EXISTING CIRCUITS FEEDING DEVICES THAT ARE TO REMAIN.

E. BE RESPONSIBLE TO REMOVE AND REINSTALL EXISTING ELECTRICAL EQUIPMENT TO ACCOMMODATE THE WORK OF OR

DISTURBED BY ALL TRADES.

F. STOCKPILE REMOVED LUMINAIRES, POWER AND COMMUNICATION DEVICES ON JOB SITE FOR REUSE UNTIL TIME OR PROJECT CLOSEOUT, THEN REMOVE THOSE FROM SITE THAT THE OWNER DOES NOT WISH TO SALVAGE.

G. REMOVE CONDUCTORS AND CONDUITS FROM REMOVED EQUIPMENT BACK TO SOURCE.

GENERAL DEMOLITION NOTES:

1/8" = 1'-0"

LEVEL 1 ELECTRICAL DEMOLITION PLAN

1. EXTEND EXISTING EXTERIOR LIGHTING CIRCUITS TO THE NEW CRITICAL PANEL CGLCH1 AND THRU RELAY PANEL LRP2

AS SHOWN IN SCHEDULE.

2. DEMOLISH CONNECTION TO AHU-11 AND ALL ASSOCIATED WIRING BACK TO THE MOTOR CONTROL CENTER MCC-MCA.

3. DEMOLISH MOTOR CONTROL CENTER MCC-MCA (BASE BID). MCC-MCA SHALL REMAIN IF DEDUCT ALT IS ACCEPTED.

4. REFER TO GENERAL DEMOLITION NOTES. REMOVE ELECTRICAL EQUIPMENT IN THESE AREAS UNLESS NOTED OTHERWISE. REMOVE ALL CIRCUITS AND FEEDERS BACK TO THE SOURCE OR ORIGIN. REMOVE EXISTING EQUIPMENT

ON WALLS TO REMAIN IN THIS AREA.

5. NOTHING SHALL BE DEMOLISHED WITHIN THIS ROOM.

6. EXISITNG PANELS L2A AND E1N TO BE REFEED ARE LOCATED IN THE ELECTRICAL ROOM ON THE FIRST FLOOR ABOVE

THIS DEMOLISHED ELECTRICAL ROOM ON THE GROUND FLOOR.

7. EXISTING PANELS L2C AND E1S TO BE REFEED ARE LOCATED IN THE ELECTRICAL ROOM ON THE FIRST FLOOR ABOVE

THIS DEMOLISHED ELECTRICAL ROOM ON THE GROUND FLOOR.

8. EXISTING PANELS L2B AND E2A TO BE REFEED ARE LOCATED IN THE ELECTRICAL ROOM ON THE FIRST FLOOR ABOVE

THIS DEMOLISHED TELECOM ROOM ON THE GROUND FLOOR.

9. EXISTING PANEL KP TO BE REFEED IS LOCATED ON THE WALL IN THE KITCHEN ABOVE.

10. ALL CIRCUITS, LIGHTS, DEVICES ETC. IN THIS LOCATION SHALL REMAIN UNLESS NOTED OTHERWISE. IN ADDITION, ALL CIRCUITS, LIGHTS, DEVICES ETC. IN THE PIPE BASEMENT SHALL ALSO REMAIN. EXISTING CIRCUITS DERIVED FROM DEMOLISHED PANELBOARDS SHALL BE EXTENDED TO NEW PANELS. FOR PURPOSE OF BID ASSUME SEVEN CIRCUITS

TO CGLNL1, SEVEN CIRCUITS TO CGLNL2, AND SEVEN CIRCUITS TO CGLNL3.

11. REMOVE AND RELOCATE EXISTING NURSE CALL PANEL. SEE EY0101 FOR NEW LOCATION.

12. REMOVE EXTERIOR LIGHT AND ASSOCIATED CIRCUIT BACK TO THE SOURCE. PATCH AND REPAIR TO MATCH EXISTING.

13. DEMOLISH CONNECTIONS TO PUMP 4 THRU 8 (BASE BID). CONNECTIONS SHALL REMAIN IF DEDUCT ALT 1 IS ACCEPTED.

14. RELOCATE LIGHT FIXTURES AS REQUIRED TO INSTALL NEW AHU AND ASSOCIATED DUCTWORK, ECT.

KEYED NOTES :

EQUIPMENT DESIGNATIONS

BUILDING

LEVEL

EQUIPMENT NAME

SEQUENCE NUMBER

NUMBERS IN SEQUENCE - 1,2,3, ETC.

ATSS AUTOMATIC TRANSFER SWITCH, LIFE SAFETY (NEC 517)

ATSC AUTOMATIC TRANSFER SWITCH, CRITICAL (NEC 517)

ATSE AUTOMATIC TRANSFER SWITCH, EQUIPMENT (NEC 517)

ATSX AUTOMATIC TRANSFER SWITCH, X-RAY

ATSM AUTOMATIC TRANSFER SWITCH, MIXED EXISTING

ATSS AUTOMATIC TRANSFER SWITCH, STANDBY (NEC 701)

ATSO AUTOMATIC TRANSFER SWITCH, OPTIONAL (NEC 702)

BPS BOLTED PRESSURE SWITCH

CB CIRCUIT BREAKER

CRT FIRE ALARM CRT ANNUNCIATOR

DS UNFUSED DISCONNECT SWITCH

FAP FIRE ALARM ANNUNCIATOR

FATC FIRE ALRAM TERMINAL CABINET

FDS FUSED DISCONNECT SWITCH

FPU FIELD PROCESSING UNIT

GC GENERAL PURPOSE CONTACTOR

IDRS INTEGRATED DATA CENTER RACK SYSTEM

IEC INTERCOM EQUIPMENT CABINET

IPC INTEGRATED POWER CENTER

LC LIGHTING CONTACTOR

LRC LIGHTING RELAY CABINET

LVS LOW VOLTAGE POWER SWITCHGEAR

MCCE MOTOR CONTROL CONTER, EQUIPMENT (NEC 517)

MCCN MOTOR CONTROL CENTER, NORMAL

MCCO MOTOR CONTROL CENTER, OPTIONAL (NEC 702)

MCCS MOTOR CONTROL CENTER, STANDBY (NEC 701)

MMC MODULAR METER CENTER

MS METER SOCKET

MTSS MANUAL TRANSFER SWITCH, STANDBY (NEC 701)

MTSO MANUAL TRANSFER SWITCH, OPTIONAL (NEC 702)

MVS MEDIUM VOLTAGE SWITCHGEAR

NEC NURSE CALL EQUIPMENT CABINET

PSS PRIMARY SUBSTATION

PSU PATIENT SERVING UNIT

PSWGR PARALLELING SWITCHGEAR

RUPS ROTARY HYBRID UNINTERRUPTIBLE POWER SUPPLY

SFP SURGICAL FACILITY PANEL

SWBDN SWITCHBOARD, NORMAL

SWBDS SWITCHBOARD, LIFE SAFETY (NEC 517)

SWBDC SWITCHBOARD, CRITICAL (NEC 517) S

SWBDE SWITCHBOARD, EQUIPMENT (NEC 517)

SWBDE SWITCHBOARD, EMERGENCY (NEC 700)

SWBDS SWITCHBOARD, STANDBY (NEC 701)

SWBDO SWITCHBOARD, OPTIONAL (NEC 702)

T TRANSFORMER

TBTP TELECOMMUNICATION BACKBONE TERMINATION PANEL

TDTP TELECOMMUNICATION DEVICE TERMINATION PANEL

TMGR TELECOMMUNICATION MAIN GROUND BUS

TMGB TELECOMMUNICATION ROOM GROUND BUS

TC TIME CLOCK

TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR

UPS UNINTERRUPTIBLE POWER SUPPLY

P PIPE BASEMENT LEVEL

G GROUND LEVEL

1 LEVEL 01

C "C" COMMUNITY LIVING CENTER

BRANCH VOLTAGE DROP

D 4 LC 1

PANELBOARDS DESIGNATIONS

BUILDING

LEVEL

TYPE

SYSTEM/SOURCE

VOLTAGE

SEQUENCE NUMBER

NUMBERS IN SEQUENCE - 1,2,3, ETC.

H 480Y/277V

L 208V/120V OR 240V

N NORMAL BRANCH

G GENERATOR POWER

S LIFE SAFETY BRANCH (NEC 517)

C CRITICAL BRANCH (NEC 517)

E EQUIPMENT BRANCH (NEC 517)

M MIXED EXISTING BRANCH

E EMERGENCY BRANCH (NEC 700)

S STANDBY BRANCH (NEC 701)

O OPTIONAL BRANCH (NEC 702)

L LIGHTING AND APPLIANCE PANELBOARD

P POWER DISTRIBUTION PANELBOARD

P PIPE BASEMENT LEVEL

G GROUND LEVEL

1 LEVEL 01

C "C" COMMUNITY LIVING CENTER

D 4 P E L 1

CONDUCTOR AWG #12 #10 #8

MAXIMUM CONDUCTOR LENGTH AT 120V 95 160 245

MAXIMUM CONDUCTOR LENGTH AT 277V 225 375 565

MAXIMUM CONDUCTOR LENGTH AT 208V 1 PH. 170 280 425

MAXIMUM CONDUCTOR LENGTH AT 480V 1 PH. 390 650 985

GROUND CONDUCTOR AWG #12 #10 #8

NOTES:

1. INCREASE BRANCH CIRCUIT CONDUCTOR AS INDICATED.

2. BASED ON 20A CIRCUIT LOADED TO 10A USING SINGLE PHASE, 2 WIRE CIRCUITS.

3. SCHEDULE REPRESENTS MINIMUM CONDUCTOR SIZE BASED ON LENGTH OF BRANCH

CIRCUIT CONDUCTOR FROM PANEL TO PHYSICAL CENTER OF LOAD TO OVERCOME VOLTAGE

DROP. 3% VOLTAGE DROP ASSUMED.

4. TRANSITION FROM LARGER CONDUCTOR SIZE TO #12 FOR FINAL TERMINATION TO OUTLET

DEVICE. PROVIDE JUNCTION BOX WITHIN 10' OF OUTLET. EXTEND #12 CONDUCTOR TO

OUTLET.

COMMUNICATION SYMBOLS

OUTLET, COMBINATION TELEPHONE/DATA COMMUNICATION

CABLE TELEVISION LINE = CATV

CLOSED CIRCUIT TELEVISION LINE = CCTV. MINIMUM 1" [25mm]

CONDUIT

FIBEROPTICS LINE = FO

TELEPHONE LINE = T

INTERCOM LINE = I. MINIMUM 3/4" [19mm] CONDUIT

SOUND LINE = S

NURSE CALL LINE = NC. MINIMUM 3/4" [19mm] CONDUIT

RADIO CONDUIT RUN, MINIMUM 3/4" [19mm] CONDUIT

FLOOR RECEPTACLE, TELEPHONE

OUTLET TELEPHONE; LETTER INDICATES AS FOLLOWS:

J = JACK TYPE W = WALL TYPE

OUTLET DATA ONLY

OUTLET; LETTER INDICATES AS FOLLOWS:

A = AUDIO V =VIDEO I = INTERCOM

SPEAKER, CEILING MOUNTED, "X" INDICATES THE TYPE, PROVIDE

SCHEDULE ON LEGEND

SPEAKER, WALL MOUNTED, "X" INDICATES THE TYPE, PROVIDE

SCHEDULE ON LEGEND. MTD. 7'-6" [2286mm] AFF UNLESS OTHERWISE

NOTED

RADIO CHANNEL SELECTOR FACILITIES, MTD. 4'-6" [1372mm] AFF

UNLESS OTHERWISE NOTED

SPEAKER PROGRAM SELECTOR SWITCH & VOLUME CONTROL MTD. 4'-

6" [1372mm] AFF UNLESS OTHERWISE NOTED

OUTLET, TEVEVISION

BLANK = 4 11/16" [119mm] MASTER ANTENNA OUTLET BOX W/BLANK

COVER, MTD. 18" [457mm] AFF UNLESS OTHERWISE NOTED.

C = CAMERA (CCTV SYSTEM), MTD 18" [457mm] AFF

M = MONITOR (CCTV SYSTEM)

NURSE'S CALL MASTER STATION MTD ON NURSE'S COUNTER TOP

UNLESS OTHERWISE NOTED

NURSE CALL TERMINAL CABINET

NURSE CALL STATION

BLANK = SINGLE PATIENT STATION WITH INTEGRAL STAFF

ASSIST AND CODE BLUE BUTTONS NTD 5'-0" [1524mm]

AFF UNLESS OTHERWISE NOTED

2 = DUPLICATE FACILITIES FOR TWO BEDS (SEPARATE

INDICATORS AT MASTER STATION) NTD 5'-0" [1524mm]

AFF UNLESS OTHERWISE NOTED

D = DUTY STATION. MTD 5'-0" [1524mm] AFF UNLESS NOTED

OTHERWISE

E = MTD 6'-0" [1829mm] AFF FOR SHOWER LOCATION, MTD 4'-6" [1372mm] AFF FOR TUB LOCATION, & MTD 3'-0" [914mm] AFF FC TOILET LOCATION

S = STAFF STATION MTD 5'-0" [1524mm] AFF UNLESS

OTHERWISE NOTED

NURSE CALL STATION

2 = NURSE'S CALL DOME LIGHT (SUFFIX INDICATES No OF

LAMP) MTD 6" [152mm] ABOVE DOOR

BLANK = CORRIDOR DOME LIGHT

I = AUXILIARY INTERSECTIONAL DOME LIGHT

TELEPHONE TERMINAL CABINET

TELEPHONE BACKBOARD (WALL MOUNTED)

REMOTE DICTATING OUTLET MTD 1'-6" [457mm] AFF. UNLESS

OTHERWISE NOTED

INTERCOM STATION (REFER TO SPECS. FOR FUNCTIONAL OPERATION

OF INSTRUMENT & TYPE REQUIRED)

INTERCOM STAFF STATION

NOTE:

FOR WHEELCHAIR PATIENT USE MOUNT TELEPHONE OUTLET 36"

[914mm] AFF TO BOTTOM OF OUTLET BOX.

DESK PHONES - MOUNT OUTLET 1'-6" [457mm] AFF

HEIGHT OF TELECART OUTLETS SHALL BE AS INDICATED ON

BEDWALLS OR PBPU DETAILS.

SEE VA BARRIER FREE DESIGN GUIDE PG-18-13.

CATV

CCTV

FO

T

II

S

NC

R

J

A

S X

S X

R

R M

M

NCS

NCT

N

N

TTB

S

ELECTRICAL SYMBOLS - POWER PLAN

MOTOR, SINGLE

TRANSFORMER, PLAN

WYE CONNECTION

DUCT, UNDERFLOOR JUNCTION BOX

EARTH GROUND

JUNCTION BOX

PULL BOX

RIGID CONDUIT LINE = RC

DIRECT BURIAL CABLE = DB

POWER DUCT = P

FLOOR OUTLET, DATA COMMUNICATION

OUTLET, DATA COMMUNICATION

PUSH BUTTON

DISTRIBUTION PANEL

LIGHTING PANEL

PANELBOARD CABINET, FLUSH MOUNTED

PANELBOARD CABINET, SURFACE MOUNTED

RECEPTACLE, CLOCK HANGER

RECEPTACLE, DUPLEX

RECEPTACLE, DUPLEX ON ESSENTIAL POWER, BRANCH INDICATED BY

CIRCUIT NUMBER

RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUIT INTERRUPTER

RECEPTACLE, QUADRAPLEX

RECEPTACLE, QUADRAPLEX ON ESSENTIAL POWER, BRANCH

INDICATED BY CIRCUIT NUMBER

RECEPTACLE, DUPLEX WITH USB OUTLETS

RECEPTACLE, SPECIAL PURPOSE

A = 120V, 20A, 1 PHASE, 2-POLE, 3W, NEMA 5-20R

B = 208V, 20A, 1 PHASE, 2-POLE, 3W, NEMA 6-20R

C = 120V, 30A, 1 PHASE, 2-POLE, 3W, NEMA 5-30R

D = 208V, 30A, 1 PHASE, 2-POLE, 3W, NEMA 6-30R

E = 208V, 60A, 1 PHASE, 3-POLE, 4W, NEMA 14-60R

F = 208V, 30A, 3 PHASE, 3-POLE, 4W, NEMA 15-30R

G = 208V, 50A, 3 PHASE, 3-POLE, 4W, NEMA 15-30R

H = 208V, 60A, 3 PHASE, 3-POLE, 4W, NEMA 15-60R

RELAY; LETTER INDICATES RELAY TYPE

50 = INSTANTANEOUS OVERCURRENT OR RATE-OF-RISE

51 = AC-TIME OVERCURRENT

67 = AC-DIRECTIONAL OVERCURRENT

86 = LOCK OUT

DISCONNECT SWITCH, FUSED

DISCONNECT SWITCH, UNFUSED

T

PB

RC

DB

P

D

DP#

LP

C

R 50

ELECTRICAL SYMBOLS - LIGHTING PLAN

WEATHER PROOF PHOTOCELL

SWITCH

BLANK = SINGLE POLE 2 = DOUBLE POLE

3 = THREE-WAY 4 = FOUR-WAY

D = DIMMER K = KEY OPERATED

LV = LOW VOLTAGE L = LOCK

LM = LOW VOLTAGE MASTER P = WITH PILOT LIGHT

PB = PUSH BUTTON STATION RC = REMOTE CONTROL

T = TIMER OPERATED WP = WEATHER PROOF

X = EXPLOSION PROOF Mo = OCCUPANCY SENSOR

LIGHT FIXTURE, DOWN LIGHT CEILING MOUNTED

LIFE SAFETY, DOWN LIGHT FIXTURE

LIGHT FIXTURE, RECESSED LED, 2'x4' [610x1220mm]

LIGHT FIXTURE, RECESSED LED, 2'x2' [610x610mm]

LIFE SAFETY, RECESSED LIGHT FIXTURE

LIGHT FIXTURE, STRIP/INDUSTRIAL LED; LETTER INDICATES TYPE

LIGHT FIXTURE, WALL MOUNTED

LIGHT POLE, ONE LUMINAIRE

LIGHT POLE, TWO LUMINAIRES

LIGHTING, EXTERIOR BUILDING

EXIT SIGN, WALL MOUNTED WITH DIRECTIONAL ARROWS AND

FACES AS SHOWN

EXIT SIGN, CEILING MOUNTED WITH DIRECTIONAL ARROWS AND

FACES AS SHOWN

LIGHT FIXTURE, DIRECTIONAL

S2

A

E

S

A. ALL FINAL LOCATIONS AND ARRANGEMENTS OF LIGHTING FIXTURES SHALL BE

OBTAINED FROM THE ARCHITECTURAL REFLECTED CEILING PLAN.

B. LIGHTING FIXTURES WITH MORE THAN TWO LAMPS SHALL HAVE TWO OUTER

LAMPS CONTROLLED WITH ONE SWITCH AND INNER LAMPS (S) CONTROLLED BY A

SECOND SWITCH

C. (1) EACH BRANCH CIRCUIT HOMERUN SHALL HAVE NO MORE THAN THREE CIRCUITS.

EACH BRANCH CIRCUIT HOMERUN SHALL HAVE A SEPARATE GREEN INSULATED EQUIPMENT

GROUNDING CONDUCTOR.

D. MULT-GANG BACKBOXES FOR DIFFERENT VOLTAGES AND TYPES OF EMERGENCY AND NORMAL

BRANCH WIRING DEVICES SHALL HAVE DIVIDERS BETWEEN DEVICES.

GENERAL NOTES

A. EXISTING EQUIPMENT, SUCH AS LIGHTING FIXTURES, WIRING DEVICES,

CONDUITS, ETC., SHOWN ON PLANS TO BE REMOVED COMPLETELY. CUT/CAP

CONDUITS AT THE AREA OF WORK PERIMETER AND REMOVE CONDUIT WITHIN

THE WORK AREA, DISCONNECT WIRING AT THE OVERCURRENT PROTECTIVE

DEVICE AND REMOVE WIRING COMPLETELY FROM THE ABANDONED CONDUITS.

B. REMOVE ALL ACCESSIBLE ABANDONED WIRING OF ALL TYPES, OR CAP AND

LABEL IN JUNCTION BOX FOR RE-USE, IN COMPLIANCE WITH THE NATIONAL

ELECTRIC CODE.

C. MAINTAIN AND RESTORE, IF INTERRUPTED, ALL CONDUITS AND CONDUCTORS

PASSING THROUGH RENOVATED AREAS AND SERVICING UNDISTURBED AREAS.

GENERAL NOTES - DEMOLITION

ELECTRICAL ABBREVIATIONS

1PH SINGLE-PHASE

1P SINGLE POLE

2/C TWO-CONDUCTOR

3/C THREE-CONDUCTOR

3PH THREE-PHASE

4/C FOUR-CONDUCTOR

4W FOUR-WIRE

A/C UNIT AIR CONDITIONING UNIT

A/E ARCHITECT/ENGINEER

AAP ALARM ANNUNCIATOR PANEL

AC ALTERNATING CURRENT OR

ARMORED CABLE

ACC ACCESSIBLE

ADDL ADDITIONAL

ADJ ADJACENT, ADJOINING

ADO AUTOMATIC DOOR OPENER

AF AMPERE FRAME OR AMP FUSE

AFC ABOVE FINISHED COUNTER,

AVAILABLE FAULT CURRENT

AFF ABOVE FINISHED FLOOR

AH AMPERE HOUR

AHJ AUTHORITY HAVING JURISDICTION

AIC AMPERE INTERRUPTING CAPACITY

ALT ALTERNATE

AMP AMPERE

ARCH ARCHITECT

ASC AMPS SHORT CIRCUIT

AT AMPERE TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AV AUDIO VISUAL

BAT BATTERY

BC BARE COPPER

BFF BELOW FINISHED FLOOR

BIL BASIC INSULATION LEVEL

BLDG BUILDING

BRKR BREAKER

BYP BY PASS

C CONDUIT

CAB CABINET

CALC CALCULATE

CAP CAPACITY

CAT CATALOG

CATV COMMUNITY ANTENNA TELEVISION

CCR CONTROL CONTACTOR

CCTV CLOSED CIRCUIT TEVEVISION

cd CANDELA

CD CONSTRUCTION DOCUMENTS

CHW CHILLED WATER

CHWP CHILLED WATER PUMP

CKT CIRCUIT

CKT BRKR CIRCUIT BREAKER

CLF CURRENT LIMITING FUSE

CLG CEILING

COAX COAX CABLE

COMM COMMUNICATION

COMPT COMPARTMENT

CONC CONCRETE

CONT CONTINUE

CONTR CONTRACTOR

COORD COORDINATE

CPT CONTROL POWER TRANSFORMER

CRI COLOR RENDERING INDEX

CT CURRENT TRANSFORMER

CTV CABLE TELEVISION

CU COPPER

CU FT CUBIC FEET

CUR CURRENT

DC DIRECT CURRENT

DCP DIMMER CONTROL PANEL

DEG C DEGREES CELSIUS

DEG F DEGREES FAHRENHEIT

DEMO DEMOLITION

DIAG DIAGRAM

DISC DISCONNECT

DISTR PNL DISTRIBUTION PANEL

DMR SW DIMMER SWITCH

DN DOWN

DPDT DOUBLE POLE, DOUBLE THROW

DPST DOUBLE POLE, SINGLE THROW

DS DISCONNECT SWITCH

DWG DRAWING

EC EMPTY CONDUIT

EG EQUIPMENT GROUND

EL ELEVATION

ELEC ELECTRIC OR ELECTRIAL

ELEV ELEVATOR

EMCP EMERGENCY MONITORING CONTROL

PANEL

EMER EMERGENCY

EMI ELECTROMAGNETIC INTERFERENCE

EMT ELECTRICAL METALLIC TUBING

ENCL ENCLOSURE

EPO EMERGENCY POWER OFF

EPRF EXPLOSION PROOF

ER EXISTING TO BE REMOVED

ERL EXISTING TO BE RELOCATED

ESMT EASEMENT

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

EX EXISTING TO REMAIN

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FC FOOTCANDLE

FIXT FIXTURE

FLA FULL LOAD AMPS

FLEX FLEXIBLE METALLIC CONDUIT

FOUTT TELEPHONE FLOOR OUTLET

FP FIRE PROTECTION

FT FEET OR FOOT

FU SW FUSED SWITCH

FVNR FULL VOLTAGE NON-REVERSING

FVR FULL VOLTAGE REVERSING

G OR GND GROUND OR GENERATOR

GEN GENERATOR

GFCI GROUND FAULT CIRCUIT

INTERRUPTER

GTB GROUND TEERMINAL BOX

HID HIGH INTENSITY DISCHARGE

HOA HAND-OFF-AUTOMATIC

HP HORSEPOWER

HT HEIGHT

HZ HERTZ

IESNA ILLUMINATION ENGINEERING

SOCIETY OF NORTH AMERICA

IMC INTERMEDIATE METAL CONDUIT

IR INFRARED

J-BOX JUNCTION BOX

kV KILOVOLT kVA KILOVOLT AMPERE kVAH KILOVOLT AMPERE PER HOUR kVAR KILOVOLT AMPERE REACTIVE kW KILOWATT kWH KILOWATT HOUR kWHM KILOWATT HOUR METER

LED LIGHT EMITTING DIODE

LF LINEAR FEET (FOOT)

LM LUMEN

LP LIGHT POLE

LRA LOCKED ROTOR AMPS

LTCP LOCAL TEMPERATURE CONTROL

PANEL

LT LIGHT

LTG LIGHTING

LTG PNL LIGHTING PANEL

LTNG LIGHTNING

LV LOW VOLTAGE

MATV MASTER ANTENNA TELEVISION

SYSTEM

MAX MAXIMUM

MC METAL-CLAD

MCA MINIMUM CIRCUIT AMPS

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MDP MAIN DISTRIBUTION PANEL

MECH MECHANICAL

MG MOTOR GENERATOR

MH MANHOLE

MIN MINIMUM

MOCP MAXIMUM OVERCURRENT

PROTECTION

MLO MAIN LUGS ONLY

MT MOUNT

MTD MOUNTED

MTG MOUNTING

MTS MANUAL TRANSFER SWITCH

MV MEDIUM VOLTAGE

MVA MEGAVOLT-AMPERE

MW MEGAWATT MICROWAVE

NA NOT APPLICABLE

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL

MANUFACTURERS ASSOCIATION

NEUT OR N NEUTRAL

NFPA NATIONAL FIRE PROTECTION

ASSOCIATION

NIC NOT IN CONTRACT

NL NIGHT LIGHT

NO NORMALLY OPEN

NS NO SCALE

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

OL OVERLOAD

P POLE

PA PUBLIC ADDRESS

PB PANELBOARD, PULL BOX, OR

PUSHBUTTON

PBPU PREFABRICATED BEDSIDE PATIENT

UNIT

PCB POLYCHLORINATED BIPHENYL

PED PEDESTAL

PEND PENDANT

PH PHASE

PNL PANEL

POD POWER OPERATED DAMPER

PT POTENTIAL TRANSFORMER

PTRV POWER TYPE ROOF VENTILATION

PVC POLYVINYL CHLORIDE (PLASTIC)

PWR POWER

RCP REFLECTED CEILING PLAN

REC RECESSED

RECPT RECEPTACLE

RGS RIGID GALVANIZED STEEL

RM ROOM

REQD REQUIRED

SCC SHORT CIRCUIT CAPACITY

SES SERVICE ENTRANCE SECTION

SD SMOKE DETECTOR

SF SQUARE FOOT (FEET)

SHT SHEET

SI INTERNATIONAL SYSTEM OF UNITS

SPEC SPECIFICATION

SPST SINGLE POLE, SINGLE THROW

SURF SURFACE

SW SWITCH

SWBD SWITCHBOARD

SWGR SWITCHGEAR

TC TIME CLOCK

TEL TELEPHONE

TP TWISTED PAIR

TPS TWISTED PAIR SHIELDED

TTB TELEPHONE TERMINAL BOARD

TV TELEVISION

TYP TYPICAL

UFD UNDERFLOOR DUCT

UGND UNDERGROUND

UL UNDERWRITERS LABORATORY

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTIBLE POWER SUPPLY

UTIL UTILITY

V VOLT

VA VOLT AMPERE

VAR VOLT AMPERE REACTIVE

VFD VARIABLE FREQUENCY DRIVE

VOLT VOLTAGE

W WATT

WH WATER HEATER

WP WEATHERPROOF

XFER TRANSFER

XFMR TRANSFORMER

STARTER, COMBINATION WITH DISCONNECT SWITCH

STARTER OR MOTOR CONTROLLER

VARIABLE FREQUENCY DRIVE

TIME CLOCK

VENTILATOR OR FAN COIL UNIT OUTLET

SWITCH

F = FUSED SWITCH K = KEY OPERATED

L = LOCK LM = LOW VOLTAGE MASTER

M = MANUAL MOTOR STARTING MC = MOMENTARY CONTACT

P = WITH PILOT LIGHT(THERMAL TYPE)

PB = PUSH BUTTON STATION RC = REMOTE CONTROL

WP = WEATHER PROOF T = THERMAL SWITCH

VFD

TC

S2

COMMUNICATION ABBREVIATIONS

AFG ABOVE FINISH GRADE

AMB OR A AMBIENT

BD BOARD

BPIP BOILER PLANT INSTRUMENTTATION

PANEL

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED/

CONTRACTOR

INSTALLED

CF/OI CONTRACTOR FURNISHED/OWNER

INSTALLED

CFE CONTRACTOR FURNISHED EQUIPMENT

CMU CONCRETE MASONRY UNIT

CTV CABLE TELEVISION

DB DECIBEL OR DIRECT BURIAL

DISTR DISTRIBUTION

DRSW DOOR SWITCH

PF POWER FACTOR

DU

# = P = LINE VOLTAGE, WALL BOX STYLE, 3'-8" AFF

P1 = WALL/CEILING MOUNT, LOW VOLTAGE, WIDE VIEW

P2 = CEILING MOUNT, LOW VOLTAGE, WIDE VIEW

INDICATES WALL MOUNT STYLE, 7'-6" AFF, UNO#

PUSH BUTTON; LETTER INDICATES AS FOLLOWS:

M = MOUNT

C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION

P-PEDESTAL R-RACK S-SURFACE W-WALL

T = TECHNOLOGY/TYPE

B-BELL PUSH D-DURESS P-PANIC R-DOOR RELEASE

X-REQUEST-FOR-EXIT

ALARM, CHECK VALVE

ALARM, FIRE, COMMUNICATOR

ALARM, FIRE, PANEL; LETTER INDICATES AS FOLLOWS:

FACC = CENTRAL CONSOLE FACP = CONTROL PANEL

MFACP = MASTER CONTROL PANEL FAAP = ANNUNCIATOR PANEL

ALARM, FIRE; LETTER INDICATES AS FOLLOWS:

BATT = BATTERIES CHR = CHARGER FAR = RECORDER

ALARM, FIRE, VALVE SUPERVISORY SWITCH

ALARM, FIRE, TERMINAL CABINET

ALARM, FIRE, POST INDICATOR VALVE

ALARM, TRANSPONDER OR TRANSMITTER

ALARM, FIRE, MANUAL PULL STATION

ALARM, GONG

ALARM, SPEAKER/LIGHT, ONE ASSEMBLY

ALARM, SPEAKER/LIGHT, ONE ASSEMBLY WITH CHIME

ALARM, SPEAKER/LIGHT, SEPARATE ASSEMBLY

ALARM, LAMP LIGHT, SIGNAL LIGHT, STROBE

ALARM, MANUAL CONTROL

ALARM, MINI SPEAKER

ALARM, CEILING SPEAKER

ALARM, SPRINKLER SYSTEM WATER FLOW BELL

ALARM, VOICE COMMUNICATION PANEL

ALARM, TAMPER SWITCH

DETECTION, GAS

DETECTION, SMOKE CONTROL AND PRESSURE PANEL

DETECTION SWITCH, ABORT

DETECTION, SWITCH, VALVE TAMPER

DETECTOR, FLAME FLICKER

DETECTOR, FLOW SWITCH

DETECTOR, HEAT

DETECTOR, HEAT; LETTER INDICATES AS FOLLOWS:

R/T = COMBINATION F = FIXED TEMPERATURE RISE

R/C = RATE COMPENSATION R = RATE OF

DETECTOR; LETTER INDICATES AS FOLLOWS:

BLANK = SMOKE DETECTOR

H = HEAT SMOKE

I = IONIZATION SMOKE

P = PHOTOELECTRIC SMOKE

IH = IONIZATION AND HEAT SMOKE

IP = IONIZATION AND PHOTOELECTRIC SMOKE

PH = PHOTOELECTRIC AND HEAT SMOKE

IPH = IONIZATION, PHOTOELECTRIC, AND HEAT

b = INTEGRAL SOUNDER BASE

DETECTOR, SMOKE, FOR DUCT

DETECTOR, SWITCH LEVEL

FIRE ALARM LINE = FA

ELECTROMAGNETIC TYPE DOOR HOLDER OUTLET

FIRE ALARM RELAY

DUCT SMOKE DETECTOR REMOTE INDICATOR AND TEST STATION

M T

ELECTRONIC SAFETY AND SECURITY SYMBOLS

AUDIO DEVICE; LETTER INDICATES AS FOLLOWS:

M=MOUNT

C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION

P-PEDESTAL R-RACK S-SURFACE W-WALL

T = TECHNOLOGY/TYPE

B-BELL C-CHIME H-HORN K-KLAXON

L-LISTEN M-MICROPHONE S-SOUNDER S-SPEAKER Z-BUZZER

CARD ACCESS READER; LETTER INDICATES AS FOLLOWS:

M = MOUNT

C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION

P-PEDESTAL R-RACK S-SURFACE W-WALL

T = TECHNOLOGY/TYPE

B-BARCODE F-ELEVATOR FLOOR CALL H-ELEVATOR HALL CALL

M-MAG STRIP P-PROXIMITY S-SMART CARD

T-TOKEN

CARD READER WITH KEYPAD; LETTER INDICATES AS FOLLOWS:

M = MOUNT

C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION

P-PEDESTAL R-RACK S-SURFACE W-WALL

ELECTRONIC LOCK; LETTER INDICATES AS FOLLOWS:

M = MOUNT

C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION

P-PEDESTAL R-RACK S-SURFACE W-WALL

T = TECHNOLOGY/TYPE

D-DEADBOLT H-HYBRID L-LATCH SET M-MAGNETIC S-STRIKE

EXIT DEVICE; LETTER INDICATES AS FOLLOWS:

T = TECHNOLOGY/TYPE

D-DELAYED EGRESS E-ELECTRIFIED M-MECHANICAL X-HIGH SECURITY

FIELD PANEL; LETTER INDICATES AS FOLLOWS:

M = MOUNT

C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION

P-PEDESTAL R-RACK S-SURFACE W-WALL

T = TECHNOLOGY/TYPE

A-ALARM C-CARD READER

KEYBOARD

KEYPAD DEVICE; LETTER INDICATES AS FOLLOWS:

M = MOUNT

C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION

P-PEDESTAL R-RACK S-SURFACE W-WALL

MONITOR; LETTER INDICATES AS FOLLOWS:

M = MOUNT

C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION

P-PEDESTAL R-RACK S-SURFACE W-WALL

T = TECHNOLOGY/TYPE

D-DATA G-GRAPHIC M-MULTISCREEN V-VIDEO

MOTION DETECTOR; LETTER INDICATES AS FOLLOWS:

M = MOUNT

C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION

P-PEDESTAL R-RACK S-SURFACE W-WALL

T = TECHNOLOGY/TYPE

D-DUAL TECHNOLOGY IR-INFRARED M-MICROWAVE U-ULTRASONIC

X-REQUEST-FOR-EXIT

M T

M

M T

FAC

FACP

BATT

OSY

FATC

PIV

FTR

C

M

WB

TS

EPO

SCCP

CP

M T

T

M T

M

M T

M T

HD

HDR/T

H

FA

DH

F

SHADING INDICATES BRANCH TYPE

TEXT INDICATES LUG / BREAKER TYPE

PANELBOARD (SINGLE LINE DENOTATION)

NORMAL BRANCH PANELBOARD

LIFE SAFETY BRANCH PANELBOARD

CRITICAL BRANCH PANELBOARD

# # CIRCUIT NUMBER (AND PANELBOARD IF SPECIFICALLY DESIGNATED)

POWER BRANCH CIRCUITS

XXX

# a XXX LUMINAIRE TAG - CORRESPONDS TO LUMINAIRE SCHEDULE

# CIRCUIT NUMBER (AND PANELBOARD IF SPECIFICALLY DESIGNATED)

a LOWER CASE LETTER(S) INDICATE MULTI-SWITCH CONTROL ARRANGEMENT.

aa DOUBLE LOWER CASE LETTER(S) INDICATE WIRED THRU NETWORK RELAY PANEL.

C# CRITICAL CIRCUIT.

L# LIFE SAFETY CIRCUIT.

LIGHTING BRANCH CIRCUITS

A SINGLE LOWER CASE LETTER (I.E. 'a') OR NO LETTER INDICATES LOCAL CONTROL THRU AN OCCUPANCY SENSOR OR SWITCH; A DOUBLE LOWER CASE LETTER (I.E. 'bb') INDICATES

CONTROL THRU CENTRAL RELAY PANEL SYSTEM.

C# CRITICAL CIRCUIT

L# LIFE SAFETY CIRCUIT

J

PC

D

F

DT

1100 Clark Avenue St. Louis, Missouri 63102

T: 314.241.6250 F: 314.241.2570

JACKSON, MS

CANNON DESIGN PROJECT NO. 03640.61

© CannonDesign 2017 - All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation.

JAN 12, 2018

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. of 82Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

COMMUNITY LIVING CENTER

RENOVATION

586-16-106NOTES, LEGENDS, SYMBOLS AND

ABBREVIATIONS

E0001

TZ JMS

D W

REF.

T L

T -0

B N

TLT-01

B N

3?

TLT-01

P1

P1

3/D

P2

P2

P2

P2 P2

P2

P2

P2

P1

P2

P2

3/D

D

LV

M o

Mo

M o

Mo

M o

M o

Mo

M o

3/ D

3/D

3/ D

D

3/D

3/ D

D

3/D

3/ D

D

3/D

3/ D

D

3/D

3/ D

D

3/ D

D

3/D

3/ D

D

3/D

3/ D

D

3/D

3/ D

D

3/D

3/ D

D

3/D

3/ D

D

3/D

3/ D

D

3/D

3/ D

D

3/D

3/ D

D

3/D

3/ D

D

3/D

3/ D

D

3/D

3/ D

D

3/D

3/ D

D

3/D

3/ D

D

3/D

3/ D

D

3/D

3/ D

D

3/D

3/ D

D

LV

LV

LV

LV

LV

LV

LV

LV

LV

LV

LV

LV

LV

P2

P2

P2

M o

M o

M o

M o

M o

M o

M o

Mo

P2

LV

LV

LV

LV

LV LV

LV

LV

A B C D E

F G

H

J K M N O P R S T U V W

Bedroom

G148 Bedroom

G149 Bedroom

G150

Bedroom

G151 Bedroom

G152

Bedroom

G153

Toilet

G153.1

Toilet

G152.1

Toilet

G151.1

Toilet

G150.1

Toilet

G149.1

Toilet

G148.1

Storage

G140.1

Alcove

G140.5

Bedroom, Bariatric

G141

Toilet

G141.1

Toilet

G142.1

Bedroom

G142

Bedroom

G143

Toilet

G143.1

Bedroom

G144

Toilet

G144.1

Toilet

G145.1

Bedroom

G145

Bedroom

G146

Toilet

G146.1Stairs

G147

Bath Suite

G154

Bedroom, Bariatric

G161

Soiled Utility

G174

Clean Utility

G173

Bedroom

G172

Bedroom

G171

Bedroom

G170

Bedroom

G169

Bedroom

G168

Bedroom

G166

Bedroom

G165

Bedroom

G164

Bedroom

G163

Bedroom

G162

Office

G123

Family Lounge

G107

Medicine Storage

G106

Telecom Closet

G113

Conference

G131

Staff Lounge

G126

Office

G127

Office

G128

Mechanical (E)

G132

Mechanical (E)

G132.1

Concierge Station

G105

Sitting Area

G104

Multi-Purpose Area

G112

Laundry

G109

Alcove

G160.5

Elec

G160.2

Storage

G160.4

Shared Office

G129

Toilet

G172.1

Toilet

G171.1

Toilet

G170.1

Toilet

G169.1

Toilet

G168.1

Toilet

G166.1

Toilet

G165.1 Toilet

G164.1

Toilet

G163.1

Toilet

G161.1

Corridor

G160

Stairs

G167

Stairs

G133

Oxygen Storage- Empty

G121

Vestibule

G100

Foyer

G101

Corridor

G140Storage

G140.2

Elec Closet

G140.4

Toilet

G130.1

Toilet

G130.2

Locker Room

G130

Office

G124

House Keeping

G122

Elevator

C1-G

Elevator

C2-G

Closet

G114

Storage/Linen Storage

G110

Storage

G160.3

Kitchen

G111

Multi-Purpose Area

G102

1 3

L1

LT1

LT1

LT1

L1

LT1

LT1

LT1

L1

LT1

LT1

L1

LT1

LT1

LT1

L1

LT1

LT1

LT1

LT1

L1

LT1

LT1

L1

LT1

LT1

LT1

L1

LT1

LT1

LT1

L1

LT1

LT2

LT1

LT1

LT1

LT1

LT1

LT1

LT1

LT1

LT1

LT1

L1

LT2

LT2

LT2

LT2

LT2

LT2

LT2

LT2

LT2 3

LT2

LT2

L1

LT2

LT2

L1

LT2

LT2

LT2

LT2

LT2

L1

LT2

LT2

LT2

L1

LT2

L1

LT2

LT2

LT2

LT2

LT2

LT2

L1

LT2

L1

LT2

LT2

LT2

LT2

LT2

LT2

LT2

LT1

DL2

DL1

DL2

DL2

DL2

DL2

DL2

DL2

DL2

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1 1

DL1

DL1

LT2

L2

LX1

L2

LX1

L2

LX1 L2

LX1

L2

LX1

L2

LX1

L2

LX1

L2

LX1

L2

LX1

L2

LX1

L2

LX1

L2

LX1

L2

LX1

WM1

DL2

DL1 2

DL1

DL1

DL1

DL1

DL1

WM1

DL1

DL1

DL2

DL2

DL2

DL2

DL2

DL2

L2

LX1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

LT2

Public Toilet

G108

Oxygen Storage - Full

G121.1

Lobby

G103

Corridor

G175

WM3

WM3

WM3

WM3

WM3

WM3

WM3

WM3

WM3

WM3

WM3

WM3

WM3

DL1

L1

DL1

DL1

DL1

DL1

DL1

L1

DL1

DL1

DL1

DL1

L1

DL1

DL1

L1

DL1

DL1

L1

DL1

DL1

DL1

DL1

DL1

DL1

L1

DL1

DL1

L1

DL1

DL1

L1

DL1

DL1

DL1

DL1

WM2

LT3

LT3

WM2

WM2

WM2

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1 3

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL13

DL1

DL1

DL1

DL1

DL1

DL1 3

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1 2

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL1

DL14

DL1

DL1

DL1

DL1

DL1

DL1 5

DL1

DL1

DL1

DL1

DL1

DL1

DL1

C14

NL1

C14

NL1

C14

NL1

C14

NL1

C14

NL1

C14

NL1

C14

NL1

C14

NL1

C14

NL1

C14

NL1

C14

NL1

C13

NL1

C13

NL1

C13

NL1

C13

NL1

C13

NL1

C13

NL1

C13

NL1

C13

NL1

C13

NL1

C13

NL1C13

NL1

DL1

DL1

DL1 5

DL1

DL1

DL1

DL1

DL1

DL1 5

DL1

DL1

DL1

DL1

DL1

WM3

DL2

DL1

DL2

DL1

DL1

DL2

DL2

DL1

DL2

DL1

DL2

DL1

DL1

DL2

DL1

DL2

DL2

DL1

DL1

DL2

WM1

WM1

WM1

WM1

WM1

WM1

WM1

WM1

WM1

WM1

DL1

DL1

DL1

DL2

WM1

DL2

DL1

WM1

WM1

DL1

DL2

DL2

DL1

WM1

WM1

DL1

DL2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

WM2

DL2

DL1

WM1

DL2

DL1

WM1

DL2

DL1

WM1

WM1

DL1

DL2

DL2

DL1

WM1

WM1

DL1

DL2

C14

NL1

C14

NL1

C14

NL1

C14

NL1

C14

NL1

C14

NL1

C14

NL1

C14

NL1

C14

NL1

C14

NL1

C14

NL1

C14

NL1

C13

NL1

C13

NL1

C13

NL1

C13

NL1

C13

NL1

C13

NL1

C13

NL1

C13

NL1

C13

NL1

C13

NL1

Office

G125

LT2

LT2

LT2

LT2

LT3

LT3

LT3

Storage

G140.3

LT3

LT3

LT3

DL1

LT3

DL2

L2

LX1

DL1

L1

DL1

aa de a b a be d a de a b a b ed aa de a b a a b d e

DL1

DL1

a d e a b a e d a bb a d e aa de a b a b ed aa de a b

LT2

LT2

C13

NL1

Toilet

G162 a de a b a d e b a a b e d a a d e e d a b a b a a e d a bb a ed aa a b b aa ed e db a a d e d e a b a

LT1

LT1

DL1

aa aa aa aa aa aa aa aa bbbbbbbbbb bb bb bb bb bb bb bb cc cc cc cc cc cc cc cc cc ee ee ee ee ee ee ee ee ee a a a aa a aaaa b b d d e a a a a a a b b d d e a a a a aaa b b d d e d d e a a a a a aa b b a a a a a a a a b b d d e e d d a a aaa aaa b b dd dd dd dd dd dd dddd dd dd dd dd dd a a aa aa a b b d d ee d d a a a a a a a a b b a a aaa aaa b b d d e a a a a a a a a b b e d d a c aaa a a a e d d a a a aaa a a a a a b b e d d a a aa aa b b e d d a aa a a a a b b e d dd d e a a a a a aa b b a a aa a a a a b b e d dd d e a a a a a aaa b b a a aaa a a a e d d a a a a a a a a b b e d d d d e a a aaa a a a a a a a a a a b b e d d d d e a a aaa aaa b b a a a a a a aa b b e d d b b b b a2

DL1

a5

DL1

Elec

G120.1

L3

WL1

L3

WL1

L3

WL1

L3

WL1

L3

WL1

c cc cc c ff ff ff ff ff ffffffffffffffff ffff ffff ffff ffff ff ff ff ff ff ff ff gg gggg gg gg gg gg

L3

WL1

L3

WL1

cc ee c c c c c c c c c c c c cccc b b c dd ee cc bb ff gg aa

DL1

a a c c c c c c c c c c cc cc cc c c c c c c c c c cc cc cc c c c cC14

NL1

c c c c c c c c c

DL1

ff f4

DL1

f

PC

EX EXEX

EX

EXEX

EX

EX EX

EXEX

EX EX

EXEX

EX EX EX

EX

ff ff ff

L2

LX1

L2

LX1

c gg

1100 Clark Avenue St. Louis, Missouri 63102

T: 314.241.6250 F: 314.241.2570

JACKSON, MS

CANNON DESIGN PROJECT NO. 03640.61

© CannonDesign 2017 - All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation.

JAN 12, 2018

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. of 82Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

COMMUNITY LIVING CENTER

RENOVATION

586-16-106LEVEL 01 LIGHTING PLAN

EL0101

TZ JMS

1. EXTEND BRANCH CIRCUITS IN THIS AREA TO THE FOLLOWING BRANCH PANELBOARDS, UNLESS OTHERWISE NOTED:

277 / 480V PANELBOARDS

CGLNH1 - NORMAL POWER

CGLSH1 - LIFE SAFETY POWER

120 / 208V PANELBOARDS

CGLCL1 - CRITICAL POWER

2. EXTEND BRANCH CIRCUITS IN THIS AREA TO THE FOLLOWING BRANCH PANELBOARDS, UNLESS OTHERWISE NOTED:

277 / 480V PANELBOARDS

CGLNH2 - NORMAL POWER

CGLSH1 - LIFE SAFETY POWER

120 / 208V PANELBOARDS

CGLCL2 - CRITICAL POWER

3. EXTEND BRANCH CIRCUITS IN THIS AREA TO THE FOLLOWING BRANCH PANELBOARDS, UNLESS OTHERWISE NOTED:

277 / 480V PANELBOARDS

CGLNH3 - NORMAL POWER

CGLSH1 - LIFE SAFETY POWER

120 / 208V PANELBOARDS

CGLCL3 - CRITICAL POWER

BRANCH CIRCUIT NOTES :

1/8" = 1'-0"

LEVEL 01 LIGHTING PLAN

A. ALL LUMINAIRES DESIGNATED AS LIFE SAFETY SHALL REMAIN UNSWITCHED.

B. ALL EXIT SIGNS SHALL REMAIN UNSWITCHED.

C. ALL LUMINAIRES IN CORRIDORS, LOBBIES, AND CIRCULATION SPACES SHALL BE CONTROLLED THROUGH LIGHTING RELAY PANEL LRP1 (DENOTED WITH DOUBLE LETTER 'aa').

D. LUMINAIRES IN INDIVIDUAL ROOMS OR SPACES SHALL BE CONTROLLED VIA LOCAL OCCUPANY SENSORS, AND MANUAL

OVERRIDES.

E. OCCUPANCY SENSORS SHALL BE PROGRAMMED FOR MANUAL 'ON', AUTO 'OFF'.

LIGHTING CONTROL NOTES:

1. ADJUST LIGHTING AS REQUIRED FOR THE INSTALLATION OF THE NEW AIR HANDLING UNIT AHU IN THIS ROOM.

2. PHOTOCELL SWITCH LOCATED ON THE ROOF ABOVE AND AIMED NORTH. COORDINATE EXACT LOCATION AND AIMING IN

THE FEILD.

N

DESIGN SCHEDULES (FOR BIDDING PURPOSES ONLY. FINAL SCHEDULING SHALL BE REVIEWED, APPROVED, CHANGED AND/OR AMENDED BY OWNER/CLIENT.

SCH-1

DAY(S)

MON-SUN ON/OFF BASED ON EXISTING PHOTOCELL.

SCH-2 MON-SUN ON AT 6 AM OFF AT 9 PM WITH OVERRIDE WITH OCCUPANCY SENSOR AND MANUAL SWITCH.

SCH-3 MON-SUN ON AT 6 AM OFF AT 9 PM WITH MANUAL OVERRIDE.

LRP1

P

FIRE ALARM FULL

BRIGHTNESS INPUT

CGLNH1

120V

1. CONTROL/COMMUNICATION WIRING IN 3/4"C.

2. BRANCH CIRCUITS OUT TO LIGHT FIXTURES TO APPLY LIGHTING CONTROL.

3. BRANCH CIRUITS OUT TO EXTERIOR LIGHT POLES CONTROLLED BY A PHOTOCELL.

KEYED NOTES :

GROUND LEVEL

PC

LRP2

P

CGLCH1

120V

1100 Clark Avenue St. Louis, Missouri 63102

T: 314.241.6250 F: 314.241.2570

JACKSON, MS

CANNON DESIGN PROJECT NO. 03640.61

© CannonDesign 2017 - All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation.

JAN 12, 2018

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. of 82Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

COMMUNITY LIVING CENTER

RENOVATION

586-16-106LIGHTING SCHEDULES

EL0201

TZ JMS

1. UNLESS OTHERWISE NOTED, BOTTOM OF FIXTURE TO BE AT 8'-0" A.F.F. COORDINATE EXACT HEIGHT AND PLACEMENT WITH EXISTING CONDITIONS TO MAINTAIN HEADROOM AND CONSISTANT SPACING.

NOTES:

LUM DELIVERED LUMENS ELV DIM ELECTRONIC LOW VOLTAGE DIMMING

EXP EXPOSED PARA PARABOLIC SP SPLINE CEILING SYSTEM UNIV UNIVERSAL 120-277VAC LM/W LUMENS/WATTS

ELBD EMERG. LTG. BYPASS DEVICE PAF PAINT AFTER FABRICATION REFL'T REFLECTOR/REFLECTANCE TBS TO BE SELECTED BY ARCH V VARIOUS

D/I DIRECT/INDIRECT NT NARROW TEE GRID PRISM PRISMATIC SS STAINLESS STEEL P-RS PENDANT RIGID STEM

DW DRYWALL LO-IRI LOW IRIDESCENT PPC POLYESTER POWER COAT S'SPEC SEMI-SPECULAR P-AC PENDANT AIR-CRAFT

CONC CONCRETE LG LAY-IN GRID PL PLASTER SPEC SPECULAR WH WHITE

ABBREVIATIONS:

E ALERT ARCHITECT TO DISCREPANCIES PRIOR TO BID.

MODIFICATIONS TO MEET THE DESIGN CRITERIA, DESCRIPTIONS, & REQUIREMENTS SPECIFIED HEREIN & IN THE PROJECT MANUAL.

D LISTED SIZES, LAMPING, & TYPES OF LUMINAIRES MAY NOT BE STANDARD PRODUCTS PRODUCED FROM ANY GIVEN MANUFACTURER OR SERIES LISTED. MANUFACTURER'S STANDARD PRODUCTS MAY REQUIRE CUSTOM

TO MEET THE REQUIREMENTS SPECIFIED HEREIN & IN THE PROJECT MANUAL.

C INCLUSION HEREIN OF MANUFACTURER'S SERIES &/OR MODEL NUMBERS DOES NOT IMPLY UNCONDITIONAL PRODUCT APPROVAL - MANUFACTURER'S STANDARD PRODUCTS MAY REQUIRE CUSTOM MODIFICATIONS

B DETERMINE SPECIFIC LUMINAIRE PART NUMBERS BASED ON THE REFERENCED PRODUCT SERIES, WRITTEN DESCRIPTIONS & PROJECT MANUAL SPECIFICATIONS.

PRODUCTS BY OTHER MANUFACTURERS MAY BE CONSIDERED, PRIOR TO BID.

A REFERENCED PRODUCTS ARE INCLUDED HEREIN, OF MANUFACTURERS & PRODUCTS, THAT GENERALLY CONFORM TO THE LUMINAIRE DESIGN INTENTS ESTABLISHED HEREIN, & IN THE PROJECT MANUAL. EQUIVALENT

GENERAL NOTES:

LED DRIVER

WL1 EXTERIOR WALL MOUNTED LED LIGHT WALL MOUNTED 8 1/2" LED INTEGRAL 277 25W REFLECTOR OPTICS ALLOW THE LIGHT ENGINE TO

BE RECESSED WITHIN THE LUMINAIRE AND HAS A

GLASS LENS.

SINGLE-PIECE DIE-CAST ALUMINUM HOUSING WITH POWDER COAT

FINISH.

WST-LED

LED DRIVER LITHONIA - EDG

LX1 ILLUMINATED "EXIT" SIGN-AC TYPE SURFACE MOUNT

WALL OR CEILING

MOUNT

LED INTEGRAL 277 5W STENCIL CUT, CODE SIZE "EXIT" LETTERS &

DIRECTIONAL CHEVRON(S)-RED ACRYLIC SHEET

BACKING

DIE-CAST ALUMINUM HOUSING-SINGLE/DOUBLE FACE-WITH

DIRECTIONAL CHEVRONS AS SHOWN

SURE-LITES - EUR

500 LUM 0-10V

3000K LED DRIVER WINONA LIGHTING - 4614 TRIAD LED

WM3 WALL MOUNTED LED WALL SCONCE WALL MOUNTED 4" LED INTEGRAL 277 12.3W OPAL ACRYLIC ETCHED BRUSHED ALUMINUM WINONA LIGHTING - 5803 BENNO LED

0-10V

3000K LED DRIVER WINONA LIGHTING - 3703 TESLA LED

WM2 WALL MOUNTED LED WALL SCONCE WALL MOUNTED 4" LED INTEGRAL 277 OPAL ACRYLIC ETCHED BRUSHED ALUMINUM WINONA LIGHTING - 5250 CISCO LED

80 CRI

1300 LUM 0-10V SONNEMAN

4000K LED DRIVER EUREKA - 3531-23-LED

WM1 VANITY LIGHT WALL MOUNTED 4" LED INTEGRAL 277 24W ACRYLIC DIFFUSER STEEL HOUSING. LBL - BA906

30 LUM 0-10V

AMBER COLOR LED DRIVER OR APPROVED SUBSTITUTION

NL1 3"X5" AMBER LED NIGHT LIGHT RECESSED WALL 1-15/16" LED INTEGRAL 120 5W 63LM/W COLORED AMBER LENSES SHIP WITH FIXTURE TO

FIELD CONVERT WHITE LED TO AMBER, BY

REPLACING CLEAR LENS WITH AMBER LENS

LOUVERED FACE PLATE, ANTI-MICROBIAL WHITE, MATTE FINISH FAIL-SAFE - MLN-AMBER

4000 LUM 0-10V METALUX - SRL

3000K LED DRIVER LITHONIA - MNSL

LT3 4' INDUSTRIAL STRIP SURFACE MOUNT/

SUSPENDED

10-3/4" LED INTEGRAL 277 31W 138 LM/W ACRYLIC, LOW PROFILE FROSTED LENS FINISH SATIN NICKEL LITHONIA - ZL1N 1

80 CRI

3800 LUM 0-10V

3000K LED DRIVER PHILIPS - CLEAR APPEAL

LT2 2' x 2' LED TROFFER RECESSED LG 4-3/8" LED INTEGRAL 277 42 W EDGE LIGHTING LIGHT GUIDE PANELS FOR UNIFORM

LIGHT, FROSTED LENS IN STURDY HINGED FRAME

DIE-FORM POST PAINTED 22 GAUGE COLD ROLLED STEEL HOUSING,

DRYWALL KIT

METALUX - ENCOUNTER

80 CRI DIM TO 10%

3400 LUM 0-10V

3000K LED DRIVER PHILIPS - CLEAR APPEAL

LT1 2' x 4' LED TROFFER RECESSED LG 4-3/8" LED INTEGRAL 277 37W EDGE LIGHTING LIGHT GUIDE PANELS FOR UNIFORM

LIGHT, FROSTED LENS IN STURDY HINGED FRAME

DIE-FORM POST PAINTED 22 GAUGE COLD ROLLED STEEL HOUSING,

DRYWALL KIT

METALUX - ENCOUNTER

85 CRI DIM TO 10%

1000 LUM 0-10V KIRLIN LRR-05435

3000K LED DRIVER PATHWAY LTG - 6VLEDWL-1100-LENSED

DL2 4" APERTURE SHOWER LED DOWNLIGHT

WET LABEL

RECESSED 6-1/8" LED INTEGRAL 277 31W 35 LM/W REGRESSED GASKETED LENS 16 GAUGE STEEL HOUSING, SLEF-FLANGE, WHITE, NON-CONDUCTIVE

TRIM

GOTHAM-EVO4-OPEN

85 CRI DIM TO 10% PORTFOLIO - LD4

1000 LUM 0-10V PHILIPS-LIGHTOLIER - C4L10DL

3000K LED DRIVER FOCAL POINT - FL4D

DL1 4" APERTURE LED DOWNLIGHT RECESSED 6-1/8" LED INTEGRAL 277 20W 50 LM/W COMFORT CLEAR DIFFUSE RELECTOR, MEDIUM

WIDE DISTRIBUTION

SELF-FLANGE, PAINTED WHITE, U.N.O GOTHAM-EVO4-OPEN WDIM

METHOD SPEC QTY SPEC VOLT

TAG DESCRIPTION

INSTALLATION DEPTH/

HEIGHT

LIGHT SOURCE DRIVER

INPUT WATTS MIN. EFF. SHIELDING/OPTICS FEATURES/OPTIONS REFERENCED PRODUCTS NOTES

LUMINAIRE SCHEDULENETWORKED LOW VOLTAGE CONTROL SCHEDULE 1

CABINET / PANEL ID: LRP1

LOCATION: G120.1

RELAY #

BRANCH CIRCUIT

SWITCH

ID

CONTROLLED LOAD

SPACE/AREA/LUMINAIRE

TAG

CONTROL

PANEL CKT # SCHEDULE NOTES

AUX.

CONTROL

R1 CGLNH1 1 aa KITCHEN SCH-3

R2 CGLNH1 2 bb HALLWAY LIGHTING SCH-3

R3 CGLNH1 2 cc MULTIPURPOSE ROOM SCH-2

R4 CGLNH1 4 dd HALLWAY LIGHTING SCH-3

R5 CGLNH1 4 ee MULTIPURPOSE ROOM SCH-2

R6 CGLNH1 1 ff HALLWAY LIGHTING SCH-3

R7 CGLNH1 1 gg HALLWAY LIGHTING SCH-3

R8 - - - SPARE

R9 - - - SPARE

R10 - - - SPARE

R11 - - - SPARE

R12 - - - SPARE

R13 - - - SPARE

R14 - - - SPARE

R15 - - - SPARE

R16 - - - SPARE

R17 - - - SPARE

R18 - - - SPARE

R19 - - - SPARE

R20 - - - SPARE

R21 - - - SPARE

R22 - - - SPARE

R23 - - - SPARE

R24 - - - SPARE

NTS

RELAY PANEL RISER DIAGRAM

NETWORKED LOW VOLTAGE CONTROL SCHEDULE 2

CABINET / PANEL ID: LRP2

LOCATION: G120.1

RELAY #

BRANCH CIRCUIT

SWITCH

ID

CONTROLLED LOAD

SPACE/AREA/LUMINAIRE

TAG

CONTROL

PANEL CKT # SCHEDULE NOTES

AUX.

CONTROL

R1 CGLNH1 6 N/A EXISTING SITE LIGHTING SCH-1

R2 CGLNH1 7 N/A EXISTING SITE LIGHTING SCH-1

R3 CGLNH1 8 N/A EXISTING SITE LIGHTING SCH-1

R4 CGLNH1 9 N/A EXISTING SITE LIGHTING SCH-1

R5 CGLNH1 10 N/A EXISTING SITE LIGHTING SCH-1

R6 CGLNH1 11 N/A EXISTING SITE LIGHTING SCH-1

R7 CGLNH1 12 N/A EXISTING SITE LIGHTING SCH-1

R8 CGLNH1 13 N/A EXISTING SITE LIGHTING SCH-1

R9 - - - SPARE

R10 - - - SPARE

R11 - - - SPARE

R12 - - - SPARE

D W

REF.

T L

T -0

B N

TLT-01

B N

3?

TLT-01

W C

R

D U

DU

DU

D U

D U

D U

D U

D U

W C

R

W C

R

W C

R

D U

DU

PCR1

J

DU DU

J

DU DU

D U

D U

DU

J

J

J

J

J

N1:

N2:

C1:

N1:

N2:

C1:

N1:

N2:

C1:

N1:

N2:

C1:

N1:

N2:

C1:

N1:

N2:

C1:

N1:

N2:

C1:

N1:

N2:

C1:

N1:

N2:

C1:

N1:

N2:

C1:

N1:

N2:

C1:

N1:

N2:

C1:

N1:

N2:

C1:

N1:

N2:

C1:

N1:

N2:

C1:

N1:

N2:

C1:

N1:

N2:

C1:

N1:

N2:

C1:

N1:

N2:

C1:

N1:

N2:

C1:

N1:

N2:

C1:

N1:

N2:

C1:

DU DU

N1:

N2:

C1:

PCR1

D U

DU

J J

J

J

J

J

N3:N3:N3:N3:N3:N3:

N3: N3: N3: N3: N3:

N3:

N3:

N3: N3: N3: N3: N3:

N3:N3:N3:N3:N3:

J

D U

D U

D U

D U

J

W C

R

J

JJ

J

JJ

J

J

JJ

J

J

T

T

J

A B C D E

F G

H

J K M N O P R S T U V W

Bedroom

G148

Bedroom

G149

Toilet

G148.1

Toilet

G149.1

Toilet

G150.1

Bedroom

G150

Bedroom

G151

Toilet

G151.1

Alcove

G140.5

Toilet

G153.1

Toilet

G152.1

Bedroom

G152

Bedroom

G153

Bath Suite

G154

Bedroom, Bariatric

G141

Toilet

G141.1

Bedroom

G142

Toilet

G142.1

Bedroom

G143

Toilet

G143.1

Storage

G140.1

Toilet

G144.1

Bedroom

G144

Bedroom

G145

Toilet

G145.1

Toilet

G146.1

Bedroom

G146

Stairs

G147

Corridor

G140

Mechanical (E)

G132.1

Mechanical (E)

G132

Office

G128

Office

G127

Staff Lounge

G126 Conference

G131

Family Lounge

G107

Office

G123

Shared Office

G129

Oxygen Storage- Empty

G121

Stairs

G133

Soiled Utility

G174

Clean Utility

G173

Laundry

G109

Telecom Closet

G113

Medicine Storage

G106

Concierge Station

G105

Sitting Area

G104

Foyer

G101

Vestibule

G100

Multi-Purpose Area

G112

Bedroom, Bariatric

G161

Bedroom

G162

Bedroom

G163

Bedroom

G164

Bedroom

G165

Bedroom

G166

Stairs

G167

Corridor

G160

Toilet

G161.1 Toilet

G162

Toilet

G163.1

Elec

G160.2

Toilet

G164.1

Toilet

G165.1

Toilet

G166.1

Storage

G160.4Alcove

G160.5

Toilet

G172.1

Toilet

G171.1

Toilet

G170.1

Toilet

G169.1

Toilet

G168.1

Bedroom

G168

Bedroom

G169

Bedroom

G170

Bedroom

G171

Bedroom

G172

EP0402

Storage

G140.2

Elec Closet

G140.4

Storage

G140.3

Multi-Purpose Area

G102

Kitchen

G111

Storage/Linen Storage

G110

Elevator

C2-G

Closet

G114

Elevator

C1-G

House Keeping

G122

Office

G124

Locker Room

G130

Toilet

G130.2

Toilet

G130.1

Elec

G120.1

Storage

G160.3

TYPICAL

BEDROOM

EP0402

EP0402

EP0402

2 3

2 3

BED

LIF

TYPICAL

BARIATRIC

BEDROOM

BED

LIF

TV

TV

TYP: BEDROOMTYP: BEDROOMTYP: BEDROOMTYP: BEDROOMTYP: BEDROOM

TYP: BEDROOMTYP: BEDROOMTYP: BEDROOMTYP: BEDROOMTYP: BEDROOM

TYP: BEDROOM TYP: BEDROOM TYP: BEDROOM TYP: BEDROOM TYP: BEDROOM

TYP: BEDROOMTYP: BEDROOMTYP: BEDROOMTYP: BEDROOMTYP: BEDROOM

TYP: BARIATRIC

POD

POD

ALV

ALV

ALV

FCU-01 FCU-02 FCU-03 FCU-04 FCU-05 FCU-06

FCU-07 FCU-08 FCU-09 FCU-10 FCU-11

FCU-12

FCU-13 FCU-14 FCU-15 FCU-16 FCU-17

FCU-18FCU-19FCU-20FCU-21FCU-22

FCU-23

EF-1

PTS

C1

C1

N1

N2

N2 N2

N2

N3

N2

N2

N2

N2

N2

N2

N1

N2

N3

N2

C1

C1

TV

C1C2C3C4C6 C5

C7 C8 C9 C10 C11

C12

G148.1

4 7 11 12 13

14 15 16 17 18

C13C13

C13

C13

TV

1 6 7 13 14

1516171819

C1

C2 C3 C4 C5 C6

C7C8C9C10C11

C12

C12

C12

C12

L2

L1

Office

G125

8 8

10 10

TV

11 11

12 12

WSH WSH WSH WSH

DRY DRY DRY DRY

13 13 13

Public Toilet

G108

MW OVN STV

DW

REF REF

18,20

19,21

22,24

23,25

REF

MW

MW

REF

Corridor

G175

C1

C1

C1

C2

C2

C2

C2

C3

C4

C4

ICE

27 27

28,3029,3132

3435 36

C5

C6

C7

C7

C7

C8 C8

L3

L4

MGP

MGP

LIF

N2

5611121718

23 24 29 30 35

6 11 12 17 18

2324293035

TV

EWC

FCU-25 FCU-24

FCU-26

20 21

ERU-1

ERP-1

ERP-2

C19

EF-2

L9

FAP

WP

EP0402

EP0401

C13

C13

C12 C12

EX

EX

EX

AC

AC

PW

C15

PW

C16

AC PW

38 C14 C16

PW

PW

C20

PW

C18

AC

AC

AC

FCU-27

ERP-1

ERP-2

ERU-1

AHU-4S

AHU-4R

VSD

VSD

FEILD VERIFY AHU-4LOCATION.

STANTION MOUNT NEW EQUIPMENT.

HTR

1100 Clark Avenue St. Louis, Missouri 63102

T: 314.241.6250 F: 314.241.2570

JACKSON, MS

CANNON DESIGN PROJECT NO. 03640.61

© CannonDesign 2017 - All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation.

JAN 12, 2018

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. of 82Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

COMMUNITY LIVING CENTER

RENOVATION

586-16-106LEVEL 01 POWER PLAN

EP0101

TZ JMS

1/8" = 1'-0"

LEVEL 01 POWER PLAN

1. EXTEND BRANCH CIRCUITS IN THIS AREA TO THE FOLLOWING BRANCH PANELBOARDS, UNLESS OTHERWISE NOTED:

120 / 208V PANELBOARDS

CGLNL1 - NORMAL POWER

CGLCL1 - CRITICAL POWER

CGLEL1- LIFE SAFETY

2. EXTEND BRANCH CIRCUITS IN THIS AREA TO THE FOLLOWING BRANCH PANELBOARDS, UNLESS OTHERWISE NOTED:

120 / 208V PANELBOARDS

CGLNL2 - NORMAL POWER

CGLCL2 - CRITICAL POWER

CGLEL1- LIFE SAFETY

277 / 480V PANELBOARDS

CGLNH2 - NORMAL POWER

3. EXTEND BRANCH CIRCUITS IN THIS AREA TO THE FOLLOWING BRANCH PANELBOARDS, UNLESS OTHERWISE NOTED:

120 / 208V PANELBOARDS

CGLNL3 - NORMAL POWER

CGLCL3 - CRITICAL POWER

CGLEL1- LIFE SAFETY

277 / 480V PANELBOARDS

CGLNH3 - NORMAL POWER

BRANCH CIRCUIT NOTES :

D W

REF.

T L

T -0

B N

TLT-01

B N

3?

TLT-01

J

GROUND

J

A

W

T T

T

T

T

J

J

J

J

A B C D E

F G

H

J K M N O P R S T U V W

Bedroom

G148

Bedroom

G149

Toilet

G148.1

Toilet

G149.1

Toilet

G150.1

Bedroom

G150

Bedroom

G151

Toilet

G151.1

Alcove

G140.5

Toilet

G153.1

Toilet

G152.1

Bedroom

G152

Bedroom

G153

Bath Suite

G154

Bedroom, Bariatric

G141

Toilet

G141.1

Bedroom

G142

Toilet

G142.1

Bedroom

G143

Toilet

G143.1

Storage

G140.1

Toilet

G144.1

Bedroom

G144

Bedroom

G145

Toilet

G145.1

Toilet

G146.1

Bedroom

G146

Stairs

G147

Corridor

G140

Mechanical (E)

G132.1

Mechanical (E)

G132

Office

G128

Office

G127

Staff Lounge

G126 Conference

G131

Family Lounge

G107

Office

G123

Shared Office

G129

Oxygen Storage- Empty

G121

Stairs

G133

Soiled Utility

G174

Clean Utility

G173

Laundry

G109

Telecom Closet

G113

Medicine Storage

G106

Concierge Station

G105

Sitting Area

G104

Foyer

G101

Vestibule

G100

Multi-Purpose Area

G112

Bedroom, Bariatric

G161

Bedroom

G162

Bedroom

G163

Bedroom

G164

Bedroom

G165

Bedroom

G166

Stairs

G167

Corridor

G160

Toilet

G161.1 Toilet

G162

Toilet

G163.1

Elec

G160.2

Toilet

G164.1

Toilet

G165.1

Toilet

G166.1

Storage

G160.4 Alcove

G160.5

Toilet

G172.1

Toilet

G171.1

Toilet

G170.1

Toilet

G169.1

Toilet

G168.1

Bedroom

G168

Bedroom

G169

Bedroom

G170

Bedroom

G171

Bedroom

G172

Storage

G140.2

Elec Closet

G140.4

Storage

G140.3

Multi-Purpose Area

G102

Kitchen

G111

Storage/Linen Storage

G110

Elevator

C2-G

Closet

G114

Elevator

C1-G

House Keeping

G122

Office

G124

Locker Room

G130

Toilet

G130.2

Toilet

G130.1

Elec

G120.1

Storage

G160.3

CGLNL2CGLCL2

CGLNL3

CGLCL3

CGLNH3

CGLNH2

CGLNL1

CGLNH1

G148.1

Office

G125

Public Toilet

G108

Corridor

G175

C11

C13 C12

C16

C14

CGPNL1

CGTN1

CGPNH1

CGLEL1

CGLCL1

CGLEH1

CGTC1

CGTE1

EDALDP

1 2

1100 Clark Avenue St. Louis, Missouri 63102

T: 314.241.6250 F: 314.241.2570

JACKSON, MS

CANNON DESIGN PROJECT NO. 03640.61

© CannonDesign 2017 - All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation.

JAN 12, 2018

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. of 82Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

COMMUNITY LIVING CENTER

RENOVATION

586-16-106LEVEL 01 FEEDER PLAN

EP0102

Checker Author

N

1/8" = 1'-0"

LEVEL 01 FEEDER PLAN

1. FEEDER ROUTING IS SHOWN FOR DESIGN INTENT PURPOSES ONLY AND SHALL BE FIELD COORDINATED AND

ADJUSTED AS REQUIRED.

2. PULL BOX SIZES AND LOCATIONS ARE NOT SHOWN. THEY SHALL BE INSTALLED TO AS REQUIRED AND MEET THE

REQUIREMENTS OF THE NEC.

3. ALL FEEDERS SHOWN ARE ROUTED IN THE PIPE BASEMENT BELOW THE GROUND LEVEL UNLESS NOTED

OTHERWISE.

4. ALL CONCRETE CORING THROUGH SLAB SHALL HAVE THE SLAB X-RAY SCANNED AND THE LOCATION VERIFIED ON A CASE BY CASE BASIS WITH THE STRUCTURAL ENGINEER PRIOR TO SLAB CORING. IF THE LOCATION IS FOUND TO

BE UNACCEPTABLE, THE LOCATION SHALL BE REVISED.

GENERAL NOTES:

1. FEEDER IS ROUTED IN THE CEILING OF THE GROUND LEVEL.

2. FEEDERS ARE ROUTED UP AND OVER THE THE WALL WERE THE TRANSITIONS DOWN INTO THE PIPE BASEMENT.

W C

R

T T

T

W C

R

T T

T

K M N O P

EF-6

AHU-10

TERTIARY

PUMP

AHU-02

AHU-12

SUPPLY

ACCESS

CONTROL PANELS

AHU-02

VSD

TERTIARY

PUMP VSD

EX

EX

EX

EX

EX

EX

ERU-1

VSD

K M N O P

EF-6

HWP-2 HWP-1

CRU-1

AHU-10

HWP-3

TERTIARY

PUMP

HWP-4

AHU-02

AHU-12

SUPPLY

HWP-5

ACCESS

CONTROL PANELS

AHU-02

VSD

TERTIARY

PUMP VSD

HWP-2

VSD

HWP-1

VSD

AHU-12

SUPPLY

VSD

AHU-12

RETURN

VSD

EX

EX

EX

EX

EX

AHU-12

RETURN

EX

CGPNH1

ERU-1

VSD

EF-6

EX

CRU-1 AHU-10

VSD

EF-1

EX

EF-2

EX

1100 Clark Avenue St. Louis, Missouri 63102

T: 314.241.6250 F: 314.241.2570

JACKSON, MS

CANNON DESIGN PROJECT NO. 03640.61

© CannonDesign 2017 - All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation.

JAN 12, 2018

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. of 82Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

COMMUNITY LIVING CENTER

RENOVATION

586-16-106ENLARGED PLANS

EP0401

TZ JMS

1/4" = 1'-0"

ENLARGED MECHANICAL ROOM

1/4" = 1'-0"

ENLARGED MECHANICAL ROOM ALTERNATE

J

J

GROUND

F

W C

R

J

J

J

J

RACK

J

RACK

J

JJ

N O P

CGLNL1

CGPNL1

L1E

LDP

EX

EDA

EX

400A CB

EX

T4

EX

SWBD

MSB

EX

UNISTRUT MOUNTED

CGLEH1

CGTC1 CGTN1

CGTE1

CGLEL1

CGLCL1

RELOCATED JOHNSON

CONTROLS BAS PANEL

NEW BAS PANEL

BAS

BAS

C9

C10

NEW EQUIPMENT

GROUND BAR

DUCT SMOKE DETECTOR RELAY

EX

CGLCH1

CGFDS1

K

CGLNH1

LRP1

LRP2

C17

CGLNL2 CGLCL2 CGLNH2

NAC

L7

CGLNH3 CGLCL3

CGLNL3

NAC

L5

TELECOMMUNICATIONS MAIN

GROUNDING BUSBAR (TMGB)

EXISTING BUILDING

GROUNDING ELECTRODE

TRANSFORMER GROUNDING

ELECTRODE (TYPICAL)

SERVICE ENTRANCE EQUIPMENT GROUND

BUS IN SWBD MSB

MECH. PIPING SYSTEM PER NEC

FIRE PROTECTION SERVICE PER NEC

GROUNDED CONDUIT(S) GROUND

BUSHINGS

TYPICAL BOLTED

COMPRESSION LUG

EQUIPMENT ROOM GROUND TERMINAL BAR SHALL BE

COPPER 1/4" THICK BY 2" WIDE BY 4' LENGTH

TO EQUIPMENT ROOM GROUND TERMINAL BAR USING MIN.

NEC SIZE BARE OR GREEN INSULATED COPPER CONDUCTOR

KEYED NOTES :

1. GROUNDING CONDUCTOR (NEUTRAL)

2. FUSION WELD (OR INDEPENDENT TRANSFER NEUTRAL LUGS)

3. GROUNDING ELECTRODE CONDUCTOR.

4. EQUIPMENT GROUNDING CONDUCTOR.

5. BONDING JUMPER.

A B

GN

C

C

A

B

G

ENCLOSURE GROUND

GROUND BUS

OUTGOING METALLIC CONDUIT

INCOMING METALLIC

CONDUIT

TRANSFORMER ENCLOSURE

1 4

RGS OR IMC

PVC CONDUIT

PVC TO RIGID

ADAPTER

WRAP ALL JOINTS 100%

WATERTIGHT

FINISHED FLOOR

THREADED CAP ON ALL SPARESTO COUPLING, PULLBOX,

PANELBOX, ETC. AS SHOWN OR

REQUIRED

TYPICAL-SEAL VAPOR

BARRIER TO CONDUIT

TYPICAL-TIE REBARS WITH #3

BARS

RGS OR IMC

TYPICAL #4 REBARS 6" O.C.

ALL AROUND

TYPICAL-CONCRETE BLOCKS.

LENGTH AS REQUIRED

KEYED NOTES :

1. AT EACH CONDUIT STUB-UP, AFFIX ENGRAVED PLASTIC NAMEPLATE INDICATING CONDUIT NO.