36C25618B0375-004.pdf
PDF 9 MB Posted
- Solicitation number
- 36C25618B0375
About this file
36C25618B0375 40_AR_VACLC_2018-01-11_IFB.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25618B0375-00004000.docx | DOCX document | |
| 36C25618B0375-00004003.pdf | ||
| 36C25618B0375-00004005.pdf | ||
| 36C25618B0375-00004004.pdf | ||
| 36C25618B0375-00004001.pdf | ||
| 36C25618B0375-00004006.pdf | ||
| 36C25618B0375-00004002.pdf | ||
| 36C25618B0375-00003000.docx | DOCX document | |
| 36C25618B0375-00002000.docx | DOCX document | |
| 36C25618B0375-00002001.pdf | ||
| 36C25618B0375-00001000.docx | DOCX document | |
| 36C25618B0375-001.docx | DOCX document | |
| 36C25618B0375-009.pdf | ||
| 36C25618B0375-010.pdf | ||
| 36C25618B0375-007.pdf | ||
| 36C25618B0375-003.pdf | ||
| 36C25618B0375-006.pdf | ||
| 36C25618B0375-008.pdf | ||
| 36C25618B0375-005.pdf | ||
| 36C25618B0375-002.pdf | ||
| 36C25618B0375-000.docx | DOCX document |
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1100 Clark Avenue St. Louis, Missouri 63102
T: 314.241.6250 F: 314.241.2570
C a n n o n
D e s ig n
A ll ri g h ts r e s e rv e d N o p a rt o f th is d o c u m e n t m a y b e r e p ro d u c e d o r u ti liz e d i n a n y f o rm w it h o u t p ri o r w ri tt e n a u th o ri z a ti o n b y T h e C a n n o n C o rp o ra ti o n
Consultants:
BOSTON NEW YORK BALTIMORE WASHINGTON DC BUFFALO TORONTO MONTREAL PITTSBURGH
CHICAGO ST. LOUIS VANCOUVER SAN FRANCISCO LOS ANGELES PHOENIX MUMBAI ABU DHABI
/1
/2
:3
:5
P
M
Renovate Ground Floor Community Living Center Jackson, MS VA Medical Center
CannonDesign Project Number: 003640.61 Project Status: FINAL DESIGN CD SUBMISSION
Issue Date: JAN. 12, 2018
U.S. Department of Veteran Affairs
VA PROJECT NO: 586-16-106
T: 314.241.6250 F: 314.241.2570
JACKSON, MS
CANNON DESIGN PROJECT NO. 03640.61
© CannonDesign 2017 - All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation.
JAN 12, 2018
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. of 81Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
COMMUNITY LIVING CENTER
RENOVATION
586-16-106DRAWING INDEX
G0001
CN GP,BB
DRAWING INDEX
SHEET NUMBER SHEET NAME R
E
V
IS
IO
N
10 GENERAL
G0000 COVER SHEET
G0001 DRAWING INDEX
G0201 GROUND FLOOR CODE COMPLIANCE
G0301 INFECTION CONTROL PLAN
G0302 CONSTRUCTION STAGING PLAN
40 ARCHITECTURAL
D0101 GROUND FLOOR DEMO PLAN
A0001 SYMBOLS & ABBREVIATIONS
A0002 ARCHITECTURAL EQUIPMENT & MOUNTING INFORMATION
A0101 GROUND FLOOR PLAN
A0201 ENGLARGED PLANS
A0601 INTERIOR ELEVATIONS
A0602 INTERIOR ELEVATIONS
A0701 GROUND FLOOR REFLECTED CEILING PLAN
A0702 ENLARGED REFLECTED CEILING PLANS
A0800 EXTERIOR WALL DETAILS
A0810 WALL PROTECTION DETAILS
A0811 FLOOR TRANSITIONS
A0841 CEILING DETAILS
A0901 CASEWORK / MILLWORK STANDARDS
A0902 CASEWORK DETAILS
A0903 CASEWORK DETAILS
A1001 PARTITION TYPES
A1002 PARTITION DETAILS
A1005 DOOR SCHEDULE & DETAILS
A1231 GROUND FLOOR FINISH PLAN
A1301 GROUND FLOOR WALL PROTECTION PLAN
50 PLUMBING
PL0001 LEGENDS, SYMBOLS & ABBREVIATIONS
PD010 UNDERFLOOR PLUMBING DEMO PLAN
PD100 LEVEL 00 PLUMBING DEMO PLAN
PL010 UNDERFLOOR PLUMBING PLAN
PL100 LEVEL 00 PLUMBING PLAN
PL301 PLUMBING ENLARGED PLANS
PL401 PLUMBING RISER DIAGRAMS
PL402 PLUMBING RISER DIAGRAMS
PL403 PLUMBING RISER DIAGRAMS
PL404 PLUMBING RISER DIAGRAMS
PL501 PLUMBING SCHEDULES
PL601 PLUMBING DETAILS
PL602 PLUMBING DETAILS
MG100 LEVEL 00 MEDICAL GAS PLAN
MG101 LEVEL 01 MEDICAL GAS PLAN
60 FIRE PROTECTION
FX0001 LEGENDS, SYMBOLS & ABBREVIATIONS
FD100 LEVEL 00 FIRE PROTECTION DEMO PLAN
FX100 LEVEL 00 FIRE PROTECTION PLAN
70 MECHANICAL
D0601 GROUND FLOOR - HVAC DEMOLITION PLAN
D0602 GROUND FLOOR - HVAC DEMOLITION PLAN
M0001 SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES
M0051 SITE PLAN
M0100 PIPE BASEMENT - HVAC DUCTWORK PLAN
M0101 GROUND FLOOR - HVAC DUCTWORK PLAN
M0200 PIPE BASEMENT - HVAC PIPING PLAN
M0201 GROUND FLOOR - HVAC PIPING PLAN
M0301 ENLARGED PLANS AND SECTIONS
M0302 ENLARGED PLANS AND SECTIONS - DEDUCT ALTERNATE
M0401 RISER DIAGRAMS
M0501 SCHEDULES
M0601 FLOW AND CONTROL DIAGRAMS
M0602 FLOW AND CONTROL DIAGRAMS
M0603 FLOW AND CONTROL DIAGRAMS
M0701 DETAILS
M0702 DETAILS
M0801 AHU COMPONENT DETAILS
80 ELECTRICAL
D0801 LEVEL 01 ELECTRICAL DEMOLITION PLAN
E0001 NOTES, LEGENDS, SYMBOLS AND ABBREVIATIONS
EL0101 LEVEL 01 LIGHTING PLAN
EL0201 LIGHTING SCHEDULES
EP0101 LEVEL 01 POWER PLAN
EP0102 LEVEL 01 FEEDER PLAN
EP0401 ENLARGED PLANS
EP0402 ENLARGED PLANS AND DETAILS
EP0501 POWER SCHEDULES
EP0502 POWER SCHEDULES
EP0503 POWER SCHEDULES
EP0521 DEMOLITION ONE LINE DIAGRAM
EP0521A DEMOLITION ONE LINE DIAGRAM ALTERNATE
EP0522 ONE LINE DIAGRAM
EP0522A ONE LINE DIAGRAM ALTERNATE
EY0101 LEVEL 01 NURSE CALL PLAN
FA0101 LEVEL 01 FIRE ALARM PLAN
FA0102 FIRE ALARM SCHEDULES
90 TELECOMMUNICATIONS
T001 NOTES, LEGENDS, SYMBOLS AND ABBREVIATIONS
TN101 LEVEL 01 TELECOMMUNICATIONS PLAN
TN401 ENLARGED PLANS
TN501 TELECOMMUNICATIONS DETAILS
TN502 TELECOMMUNICATIONS RISER DIAGRAMS
TN503 TELECOMMUNICATIONS SCHEDULE
TY101 LEVEL 01 SECURITY SYSTEMS PLAN
TY501 SECURITY SYSTEMS DETAILS
S SS S
S SS
S S
S S
SS
UP
UP
SS
SS
SS
SS SS
SS
SS
SS
SS
S S
S S
S S
SS
SS
SS
SS
SS
AHJ CODE, STANDARD, OR ORDINANCE
1 2012 NFPA 101 LIFE SAFETY CODE
3 2012 INTERNATIONAL BUILDING CODE
1 VA HVAC DESIGN MANUAL FOR CLC AND DOM - MAR. 2011
1 VA PLUMBING DESIGN MANUAL - NOV. 2014
1 2012 INTERNATIONAL ENERGY CONSERVATION CODE
2 2012 NFPA 99 FIRE SAFETY CODE
1 VA ELECTRICAL DESIGN MANUAL - DEC. 2015
VARIOUS OTHERS, REFER TO SPECIFICATIONS AND GENERAL NOTES
IN EACH DISCIPLINE
APPLICABLE CODES,
STANDARDS, AND ORDINANCES:
BEARING WALLS :
EXTERIOR
INTERIOR
2 HRS
FIRE RATING FIRE RATINGITEM
0 HRS
NON-BEARING WALLS
AND PARTITIONS
2 HRSSTRUCTURAL FRAME
2 HRS
0 HRSINTERIOR
2 HRSFLOOR CONSTRUCTION
1 HRROOF CONSTRUCTION
IBC 2012 - TABLE 601 - TYPE 1B1. BUILDING OFFICIAL
VISN SAFETY OFFICE
2. FIRE PREVENTION OFFICIAL
VISN SAFETY OFFICE
3. CITY OF JACKSON MS
BUILDING DIVISION
AUTHORITIES HAVING
JURISDICTION:
NFPA 220 - TABLE 4.1.1 - TYPE II/222
COLUMNS
BEAMS, GIRDERS, TRUSSES AND
ARCHES
SUPPORTING MORE THAN 1 FLOOR
SUPPORTING 1 FLOOR ONLY
SUPPORTING ROOF ONLY
SUPPORTING MORE THAN 1 FLOOR
SUPPORTING 1 FLOOR ONLY
SUPPORTING ROOF ONLY
EXTERIOR
SEPARATION >30'
2 HRS
2 HRS
1 HRS
2 HRS
2 HRS
1 HRS
FLOOR - CEILING ASSEMBLIES
ROOF - CEILING ASSEMBLIES
2 HRS
2 HRS
1 HRS
SUPPORTING MORE THAN 1 FLOOR
SUPPORTING 1 FLOOR ONLY
SUPPORTING ROOF ONLY
EXTERIOR BEARING WALLS
INTERIOR BEARING WALLS
SUPPORTING MORE THAN 1 FLOOR
SUPPORTING 1 FLOOR ONLY
SUPPORTING ROOF ONLY
2 HRS
2 HRS
1 HRS
EXTERIOR NON-BEARING WALLS
SEPARATION >30'
INTERIOR BEARING WALLS
0 HRS
0 HRS
FIRE RESISTANCE RATINGSBUILDING INFORMATION:
MAXIMUM TRAVEL DISTANCES:
TRAVEL DISTANCES
ALLOWABLE MAX. IN ANY ROOM TO EXIT ACCESS DOOR = 50'
ALLOWABLE MAX. IN SLEEPING SUITE TO EXIT ACCESS DOOR = 100'
COMMON PATH OF TRAVEL (CP)
ALLOWABLE MAXIMUM = 100'
EXIT ACCESS TRAVEL DISTANCE
ALLOWABLE MAXIMUM = 200'
DEAD ENDS
ALLOWABLE MAXIMUM = 20'
CONSTRUCTION CLASSIFICATION:
CONSTRUCTION TYPE: NFPA 220 TYPE II/222, TYPE IIA (IBC)
TOTAL BUILDING FLOOR AREA (GROUND FLOOR) = 22,700 SF
PROJECT RENOVATED FLOOR AREA (GROUND FLOOR) = 21,978 SF
MAXIMUM OVERALL BUILDING STORIES = 4 STORIES + BASEMENT
PROJECT AREA STORIES = 2 STORIES
PROJECT AFFECTED STORIES = 1 STORY (GROUND FLOOR)
SUMMARY
SUPPORTING ROOF ONLY 1 HR
INTERIOR
SUPPORTING ROOF ONLY 1 HR
2 HRS
1 HR
SHAFT ENCLOSURES
VERTICAL EXIT ENCLOSURES
2 HRS
1 HR
CORRIDORS 0 HRS
SMOKE BARRIERS 1 HR
SOILED LINEN ROOMS NA
2 HRS
1 HR
0 HR SMOKE
IBC 2012: NFPA 101:
MISCELLANEOUS RATINGS:
SUMMARY
FIRE RATING
1 HR
4 OR MORE STORIES
<4 STORIES
SHAFT ENCLOSURES
VERTICAL EXIT ENCLOSURES
CORRIDORS
SOILED LINEN ROOMS
4 OR MORE STORIES
<4 STORIES
2 HRS
1 HR
2 HRS
1 HR
4 OR MORE STORIES
<4 STORIES
4 OR MORE STORIES
<4 STORIES
SMOKE BARRIERS 1 HR
2 HRS
1 HR
0 HR SMOKE
1 HR
2 HRS
1 HR
1 HR
2 HRS
2 HRS
1 HRS
2 HRS
2 HRS
1 HRS
2 HRS
2 HRS
2 HRS
2 HRS
2 HRS
1 HRS
0 HRS
0 HRS
2 HRS
1 HR
GENERAL INFORMATION:
BUILDING IS FULLY SPRINKLERED
AUTOMATIC SPRINKLER SYSTEM: YES NFPA 13
FIRE ALARM SYSTEM: YES NFPA 72
STANDPIPE SYSTEM: YES NFPA 14
OCCUPANCY:
OCCUPANCY CLASSIFICATION: HEALTH CARE - INPATIENT (NFPA CH. 19)
I-2 (IBC)
PRIMARY USE: RESIDENTIAL CARE
ACCESSORY OCCUPANCY: NONE
SMOKE/FIRE COMPARTMENT SUMMARY
MAXIMUM AREA OF EACH SMOKE COMPARTMENT: 22,650sf
ACTUAL AREA: REFER TO KEY PLANS
ACCESSIBILITY:
THE PROJECT IN GENERAL IS DESIGNED TO MEET THE
ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARD (ABAAS)
FOR FEDERAL FACILITIES, EXCEPT WHERE MODIFIED PER THE VA
BARRIER FREE DESIGN STANDARD PG-18-13 (1/1/2017 VERSION).
ALL PATIENT BEDROOMS AND BATHROOMS ARE ACCESSIBLE PER THE
ABOVE GUIDELINES. IN ADDITION, ALL PATIENT BEDROOMS AND
BATHROOMS ARE PROVIDED WITH OVERHEAD LIFT DEVICES.
PROVIDED
2 HRS
(1)
FIRE RATING FIRE RATING
N/A (2)
0 HRS
(1)
2 HRS(1)
2 HRS(1)
N/A
2 HRS (3)
N/A
2 HRS (3)
N/A
1 HRS
1) EXISTING POURED-IN-PLACE CONC STRUCTURE CONSISTING OF 18" SQ COLUMNS (TYP) AND 6" SLAB (TYP)
2) NO BEARING WALLS IN PROJECT
3) PER ORIGINAL CONSTRUCTION DOCUMENTS (2 LAYERS 5/8" GWB EA. SIDE OF METAL STUDS)
PROVIDED
FIRE RATING
LEGEND
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
FIRE HOSE VALVE CABINET OR
STANDPIPE CONNECTION
FIRE ALARM ANNUNCIATOR PANEL
FIRE DEPARTMENT CONNECTION
1 HOUR FIRE
1 HOUR FIRE / SMOKE
2 HOUR FIRE
2 HOUR FIRE / SMOKE
3 HOUR FIRE
3 HOUR FIRE / SMOKE
4 HOUR FIRE
4 HOUR FIRE / SMOKE
ABLE TO RESIST PASSAGE OF SMOKE
EXIT ACCESS CORRIDOR
EXIT
ANN
FE
FEC
FHV
AREA OF RESCUE
EXIT STAIR
EGRESS PATH/ TRAVEL DISTANCE
EXIT
HORIZONTAL EXITHE
EXIT DISCHARGED
XX'
1125A
1125A
1125A
XX'
XX'
TOTAL EXIT ACCESS TRAVEL DISTANCE
TRAVEL DISTANCE
IN-ROOM OR IN-SUITE
TRAVEL DISTANCE
EXIT ACCESS DOOR
TO EXIT
SMOKE BARRIER
STORAGE SPACES > 100 SF
1B1B
6225 SF
1C1C
5327 SF
1A1A
10763 SF
THE FLOOR PLAN BACKGROUND FOR NEW AND EXISTING CONSTRUCTION IS
SHOWN IN GRAY HALF-TONE.
DESIGNATIONS FOR FIRE RATED PARTITIONS, SMOKE PARTITIONS AND OTHER
CODE COMPLIANCE RELATED INFORMATION ARE SHOWN FULL TONE. REFER
TO CONTRACT DRAWINGS TO DETERMINE WHICH COMPONENTS ARE NEW
AND WHICH ARE EXISTING.
THE FIRE AND SMOKE DESIGNATIONS FOR EXISTING CONSTRUCTION ARE
SHOWN FOR REFERENCE ONLY AND ARE BASED ON INFORMATION PROVIDED
BY OWNER. THIS INFORMATION HAS NOT BEEN INDEPENDENTLY VERIFIED BY
CANNON DESIGN.
REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF EXIT LIGHTS,
EMERGENCY LIGHTS, AND FIRE ALARM
SYSTEM.
REFER TO FIRE PROTECTION DRAWINGS FOR LOCATIONS OF SPRINKLERS
AND FIRE PUMP.
REFER TO PLUMBING DRAWINGS FOR PLUMBING FIXTURE COUNTS.
1.
2.
3.
4.
5.
EXIT
EXIT
EXIT
EXIT
EXIT - SMOKE COMPARTMENT
1B
2B
2A
1A
Storage/Linen Storage
G110
Public Toilet
G108
Clean Utility
G173
Soiled Utility
G174 Lobby
G103
Medicine Storage
G106
Elevator Elevator
Oxygen Storage- Empty
G121
Mechanical (E)
G132
Laundry
G109
Stairs
G133
Mechanical (E)
G132.1
Oxygen Storage
- Full
G121.1
G100
G140 X009
X003
X007
FHC
FEC
FEC
Stairs
G167
Vestibule
G100Stairs
G147
Conference
G131
House Keeping
G122
FEC
X133
X004
OPEN KITCHEN PER NFPA 101-2012
18.3.2.5.3
G160FEC
FEC
AR-01
(EXISTING BUILDING)
1100 Clark Avenue St. Louis, Missouri 63102
T: 314.241.6250 F: 314.241.2570
JACKSON, MS
CANNON DESIGN PROJECT NO. 03640.61
© CannonDesign 2017 - All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation.
JAN 12, 2018
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. of 81Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
COMMUNITY LIVING CENTER
RENOVATION
586-16-106GROUND FLOOR CODE COMPLIANCE
G0201
CN GP,BB
EGRESS CAPACITY - DOORS
DOOR NO.
CLEAR
OPENING W
ID
T H
/O C
C
OCC CAPACITY O
C
C L
O A
D
C O
M P
L
IE
S
G100 4'-0" 0.20 240 103 Yes
X003 3'-6 3/4" 0.20 213 103 Yes
X004 3'-6 3/4" 0.20 213 103 Yes
X007 5'-10 3/4" 0.20 353 103 Yes
X009 3'-0" 0.20 180 103 Yes
GROUND FLOOR SMOKE COMPARTMENT KEY PLAN
GENERAL NOTES
SPACE AREA
OCCUPANCY
S F
/O C
C
F
IX
E D
O C
C
TOTAL
OCCUPANTSTYPE FUNCTION
LOBBY 5305 SF A-u Assembly - unconcentrated 15 0 354
NORTH WING 5520 SF I-s Institutional - sleeping 120 0 46
SOUTH WING 6429 SF I-s Institutional - sleeping 120 0 54
WEST WING 5571 SF B Business 100 0 56
GROUND FLOOR 511
Grand total: 4 511
OCCUPANT LOAD
GROUND FLOOR CODE COMPLIANCE PLAN
EGRESS
DISTANCES
Mark Egress Distance
1 - GENERAL
1A 80'-5 3/4"
1B 121'-3"
2 - SMOKE COMPARTMENT
2A 122'-8 3/8"
2B 128'-8"
A
A
B
B
C
C
D
D E
F
F G
H
J
K
M
N
O
P
P
R
S
T
T
U
U
V
V
W
W
PROJECT LIMIT LINE
CONSTRUCTION BARRIER
L
5'-0"
SECURE THIS DOOR LEAF
DURING CONSTRUCTION.EXIT TO REMAIN OPEN DURING MAIN PHASE
OF CONSTRUCTION. COMPLETE WORK IN
THIS ZONE AFTER MAIN PHASE IS
COMPLETE.
MAIN PHASE CONSTRUCTION
ENTRANCE - ACCESSIBLE FROM
EXTERIOR ONLY
THIS DOOR LEAF TO REMAIN OPERATIONAL
AS AN EXIT PATH DURING ENTIRETY OF
CONSTRUCTION. MAIN
HOSPITAL
SECONDARY PHASE BARRIER AND ACCESS DOOR TO CREATE ANTE
SPACE. DOOR TO BE SIGNED AS AN EXIT AND PROVIDED WITH EXIT
DEVICE. ADDITIONAL SIGNAGE TO NOTE "CONSTRUCTION PERSONNEL
ONLY BEYOND THIS POINT".
EXIT
ACCESS
THROUGH
NEW
BUILDING
MAIN PHASE
SECONDARY PHASE
1. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO
PROPOSE A PHASING PLAN TO MEET THE REQUIREMENTS OF
THE CONSTRUCTION CONTRACT. ANY PHASING INFORMATION
PROVIDED IN THE DOCUMENTS IS FOR INFORMATIONAL /
BIDDING PURPOSES ONLY.
2. ISOLATE HVAC SYSTEM IN AREAS WHERE WORK IS BEING
DONE TO PREVENT CONTAMINATION OF DUCT SYSTEM.
3. ISOLATE WORK AREAS WITH CRITICAL BARRIERS BEFORE
WORK BEGINS.
4. MAINTAIN NEGATIVE PRESSURE WITHIN WORK SITES USING
HEPA EQUIPPED AIR FILTRATION UNITS.
5. SEAL HOLES, PIPES, CONDUITS AND PUNCTURES
APPROPRIATELY AS SOON AS DETECTED.
6. COORDINATE PERSONNEL INFECTION CONTROL
PROCEDURES WITH VA PRIOR TO COMMENCING WORK.
7. IF REQUIRED, CONSTRUCT ANTEROOM FOR ACCESSING ALL
ALL WORK AREAS. ALL PERSONNELL MUST PASS THROUGH
ANTEROOM PRIOR TO ENTERING WORK AREAS. IF REQUIRED,
WORKERS MUST BE VACUUMED USING A HEPA VACUUM CLEANER
BEFORE LEAVING WORK AREA OR WEAR COVERALLS THAT ARE
REMOVED AND REPLACED EACH TIME LEAVING THE WORK AREA.
8. ALL PERSONNEL ENTERING WORK SITE ARE REQUIRED TO WEAR
SHOE COVERS. SHOE COVERS MUST BE REMOVED EACH TIME
THE WORK AREA IS EXITED.
9. PROVIDE ADHESIVE WALK-OFF MATS AT ENTRANCE TO WORK
AREA. IF THERE IS AN ANTEROOM, A MAT SHOULD BE WITHIN THIS
AREA. REPLACE MATS DAILY OR WHEN THEY NO LONGER ARE
ABLE TO CONTAIN DUST AND DIRT.
10. WET MOP AND/ OR VACUUM WORK AREA WITH HEPA FILTERED
VACUUM BEFORE LEAVING WORK AREA.
11. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN
TIGHTLY COVERED CONTAINERS.
12. DO NOT REMOVE BARRIERS FROM WORK AREAS UNTIL
AREA IS THOROUGHLY CLEANED BY ENVIRONMENTAL
SERVICES.
13. REMOVE BARRIER MATERIALS CAREFULLY TO MINIMIZE
SPREADING OF DIRT AND DEBRIS ASSOCIATED WITH
CONSTRUCTION.11. PROVIDE TEMPORARY SIGNAGE AND
DIRECTION FLOOR EGRESS SIGNAGE AT AREAS WHERE
WORK OCCURS.
14. LIMIT FOOTPRINT OF BARRIERS AT CORRIDORS AND
ELEVATOR LOBBIES SO THAT CLEAR WIDTH OF
REMAINING PATH OF TRAVEL IS NOT LESS THAN 5'-0".
15. AT NO TIME SHALL MORE THAN 1 (ONE) OF EACH TYPE
OF ELEVATOR (PASSENGER AND SERVICE) BE
REMOVED FROM SERVICE.
16. EXTERIOR SPACE ON-SITE WILL BE PROVIDED FOR
STORAGE OF CONSTRUCTION RELATED MATERIALS
AND EQUIPMENT.
17. CONTRACTOR HAS SOLE RESPONSIBILITY TO DETERMINE
CORRECT PHASING TO MATCH THE REQUIREMENTS OF
THE CONSTRUCTION CONTRACT AS WELL AS THE ACTUAL
LOCATIONS AND THE METHODS THROUGH WHICH TO
CONSTRUCT THE ICHR COMPLIANT CONSTRUCTION
BARRIER.
18. THIS PROJECT SHOULD BE CONSIDERED TYPE "D" FOR IC
RISK ASSESSMENT PURPOSES.
1100 Clark Avenue St. Louis, Missouri 63102
T: 314.241.6250 F: 314.241.2570
JACKSON, MS
CANNON DESIGN PROJECT NO. 03640.61
© CannonDesign 2017 - All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation.
JAN 12, 2018
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. of 81Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
COMMUNITY LIVING CENTER
RENOVATION
586-16-106INFECTION CONTROL PLAN
G0301
CN GP,BB
1/8" = 1'-0"
PHASING/STAGING PLAN
CONSTRUCTION GENERAL NOTES
OWNER'S PRE-CONSTRUCTION INFECTIOUS CONTROL RISK ASSESSMENT REQUIRED PRIOR TO CONSTRUCTION.
T: 314.241.6250 F: 314.241.2570
JACKSON, MS
CANNON DESIGN PROJECT NO. 03640.61
© CannonDesign 2017 - All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation.
JAN 12, 2018
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. of 81Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
COMMUNITY LIVING CENTER
RENOVATION
586-16-106CONSTRUCTION STAGING PLAN
G0302
CN GP,BB
NTS
STAGING PLAN
4 4
PROJECT LIMIT LINE
MAIN HOSPITAL
P R
O J E
C T
L
IM
IT
L
IN
E
D0101
DEMOLITION GENERAL NOTES:
A. COMPLETELY REMOVE EXISTING CEILING ASSEMBLY INCLUDING ALL HANGERS AND SUPPORTS, LIGHT, GRILLES, SPEAKERS, SMOKE DETECTORS, EXPANSION JOINTS ETC. COORDINATE WITH MECHANICAL/ ELECTRICAL/ PLUMBING FOR DEVICES TO REMAIN AND FOR THE INSTALLATION OF NEW FIXTURES.
B. COMPLETELY REMOVE RESILIENT TILE FLOORING INCLUDING, ADHESIVES, ETC. TO EXPOSED CONCRETE. PREPARE SURFACE TO RECEIVE NEW FLOORING AS INDICATED IN THE ROOM FINISH
SCHEDULE.
C. AT ALL EXTERIOR WALLS AND ALL COLUMNS, REMOVE FURRING AND GYPSUM WALL BOARD.
1100 Clark Avenue St. Louis, Missouri 63102
T: 314.241.6250 F: 314.241.2570
JACKSON, MS
CANNON DESIGN PROJECT NO. 03640.61
© CannonDesign 2017 - All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation.
JAN 12, 2018
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. of 81Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
COMMUNITY LIVING CENTER
RENOVATION
586-16-106GROUND FLOOR DEMO PLAN
D0101
CN GP,BB
1/8" = 1'-0"
GROUND FLOOR DEMO PLAN
DEMOLITION KEYED NOTES:
NUMBER DESCRIPTION
1 CAREFULLY COMPLETELY REMOVE EXISTING MILLWORK/CASEWORK. PATCH ALL DISTURBED
CONSTRUCTION TO MATCH ADJACENT EXISTING OR PREPARE SURFACE TO RECEIVE NEW FINISH
AS INDICATED IN THE ROOM FINISH SCHEDULE.
2 COMPLETELY REMOVE EXTERIOR CURTAIN WALL SYSTEM; OR STOREFRONT WINDOW OR LOUVER
SYSTEM INCLUDING ALL DOORS, HARDWARE, MECHANICAL DIFFUSERS AND ELECTICAL DEVICES.
PATCH ALL DISTURBED CONSTRUCTION TO MATCH ADJACENT EXISTING OR PREPARE SURFACE TO
RECEIVE NEW FINISH AS INDICATED IN THE ROOM FINISH SCHEDULE.
3 REMOVE EXISTING MASONRY WALLS OR PORTIONS OF WALLS REQUIRED TO INSTALL NEW LOUVER, RE: MECH DWGS.
4 SHOWER AREAS WITH EXISTING SLOPED FLOORS TO BE INFILLED TO PROVIDE FLUSH FLOORS
THROUGHOUT.
5 REMOVE/REPLACE BROKEN SPANDREL WITH INSULATED METAL PANEL.
6 THIS ZONE TO RECEIVE NO GENERAL DEMOLITION. HOWEVER, ZONE MAY HAVE CUTTING AND
PATCHING ASSOCIATED WITH CONNECTIONS TO NEW SERVICES.
1/4" = 1'-0"
SPANDREL PANEL ELEVATION
C
D
PARTITION PARTITION TYPE
INTERIOR DOOR
ASSEMBLY
SUFFIX ADDED IF
MULTIPLE DOORS
SERVE SAME ROOM
EXTERIOR
GLAZED
OPENINGS
LOUVER
ROOM NAME
AND NUMBER 1125
ROOM NAME
ROOM NUMBER
SHEET NOTE
DEMOLITION
CONSTRUCTION
KEYNOTE
SPECIFICATION
SECTION
SPECIFIED ITEM
1125A
OFFICE
EXTERIOR DOOR
ASSEMBLY
BORROWED
LIGHT
ROOM NUMBER
EQUIPMENT
EQUIPMENT IDENTIFIER
ROOM NUMBER
SERVED BY DOOR
NUMBERED
SEQUENTIALLY
DENOTES
EXTERIOR DOOR
SUFFIX ADDED IF
MULTIPLE OPENINGS
SERVE SAME ROOM
NUMBERED
SEQUENTIALLY
DENOTES
EXTERIOR OPENING
042000 - UNIT MASONRY
ROOF ASSEMBLY TAG
SOFFIT ASSEMBLY TAG
EXTERIOR WALL
ASSEMBLY TAG
WALL SECTION
DETAIL/ SECTION
NUMBER
SHEET NUMBER
BUILDING SECTION
EXTERIOR ELEVATION
SHEET NUMBER
ELEVATION NUMBER
INTERIOR ELEVATION
ELEVATION NUMBER
SHEET NUMBER
LARGE SCALE BLOWUP
OF PLAN OR DETAIL
PLAN OR DETAIL
NUMBER
SHEET NUMBER
LEVEL REFERENCE
LEVEL DESCRIPTION
LEVEL ELEVATION
NEW
STRUCTURAL GRID
GRID REFERENCE
GRID LINE
EXISTING
STRUCTURAL GRID
EXISTING GRID
REFERENCE
EXISTING GRID LINE
MATCH LINE
SHEET NUMBER
SHEET NUMBER
MATCH LINE
REVISION
REVISION NUMBER
(SHEET SPECIFIC)
CLOUDED AREA
OF REVISION
NORTH ARROW
SIMILAR INDICATION
DETAIL SECTION
R
DETAIL / SECTION
NUMBER
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
SPOT ELEVATION
REFERENCE TYPE,
AS NEEDED:
TYP OR SIM
REFERENCE SYMBOLS (ALL DISCIPLINES)__________ REFERENCE SYMBOLS (ARCHITECTURAL)_______
CEILING HEIGHT
HEIGHT OF
CEILING ABOVE
FINISHED FLOOR
LAY IN PANEL
SURFACE OR
RECESSED
LUMINAIRE
SPRINKLER HEAD
AIR DEVICE -
RETURN
OCCUPANCY SENSOR
SMOKE DETECTOR
HEAT DETECTOR
SPEAKER
FIRE ALARM SPEAKER F
AIR DEVICE -
SUPPLY
AIR DEVICE -
EXHAUST
DAYLIGHT SENSOR
RADIANT PANEL
ACCESS DOOR
PENDANT HUNG
LUMINAIRE
AIR DEVICE -
LINEAR SUPPLY
MOTION / SECURITY
DETECTOR
CAMERA
CLOCK
M
P
H
S
S
REFLECTED CEILING PLAN SYMBOLS)_________________________________
AC AIR CONDITIONING
ACC ACCESSIBLE
ACM ASBESTOS CONTAINING MATERIAL
ADJ ADJACENT
AFF ABOVE FINISHED FLOOR
AGF ARCHITECTURAL GLASS FLOORING
AHU AIR HANDLING UNIT
ALUM ALUMINUM
ALT ALTERNATE
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATE
ARCH ARCHITECT(URAL)
ASN ABRASIVE STAIR NOSING
ATC ACOUSTICAL TILE CEILING
AUTO AUTOMATIC
AWP ACOUSTICAL WALL PANEL
BLDG BUILDING
BLKG BLOCKING
BRG BEARING
BSMT BASEMENT
C COURSE
CB SELF-COVE BASE
CFCI CONTRACTOR FURNISHED - CONTRACTOR INSTALLED
CF CONDUCTIVE FLOORING
CFMF COLD-FORMED METAL FRAMING
CG CORNER GUARD
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLO CLOSET
CLR CLEAR(ANCE)
CLRM CLASSROOM
CMT CERAMIC MOSAIC TILE
CMTB CERAMIC MOSAIC TILE BASE
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONF CONFERENCE
CONT CONTINUOUS
CONTR CONTRACT(OR)
CORR CORRIDOR
CPT CARPET(ING)
CR CRASH RAIL
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CUH CABINET UNIT HEATER
CW CASEWORK
DEMO DEMOLISH / DEMOLITION
DEPT DEPARTMENT
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DN DOWN
DS DOWNSPOUT
EA EACH
EIFS EXTERIOR INSULATION FINISH SYSTEM
EJ EXPANSION JOINT
ELEC ELECTRIC(AL)
EL ELEVATION
ELEV ELEVATOR
EM ENTRANCE MATS
EMB ELECTRONIC MARKER BOARD
EMER EMERGENCY
EOS EDGE OF SLAB
EQ EQUAL
EQUIP EQUIPMENT
ER EPOXY RESIN
EST ESTIMATE(D)
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION
EXPD EXPOSED
EXT EXTERIOR
EWC ELECTRIC WATER COOLER
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FG FOOT GRILLE
FHC FIRE HOSE CABINET
FIN FINISH(ED)
FLR FLOOR
FT FOOT/FEET
FTG FOOTING
FURN FURNISH(ED) / FURNISHINGS
FWP FABRIC WRAPPED PANEL
GA GAUGE / GAGE
GALV GALVANIZED
GFRC GLASS FIBER REINF CONCRETE
GFRG GLASS FIBER REINF GYPSUM
GL GLASS
GLMT GLASS MOSAIC TILE
GLMU GLASS MASONRY UNIT
GLT GLASS TILE
GST GLASS STAIR TREAD
GWB GYPSUM WALL BOARD
GWB P GYPSUM WALL BOARD PAINTED
GWP EP GYPSUM WALL BOARD EPOXY PAINTED
GYP GYPSUM
HDW HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HOSP HOSPITAL
HP HIGH POINT
HPC HIGH PERFORMANCE COATING
HPL HIGH PRESSURE DECORATIVE LAMINATE
HR HANDRAIL
HSS HOLLOW STRUCTURAL SECTION
HT HEIGHT
HVAC HEATING-VENTILATING-AIR CONDITIONING
HWB HEAT WELDING BEAD
ID INSIDE DIAMETER
INST INSTALL(ED)
INSUL INSULATION / INSULATED
INT INTERIOR
JAN JANITOR
JT JOINT
KIT KITCHEN
LAB LABORATORY
LAM LAMINATE(D)
LAV LAVATORY
LGT LENGTH
LH LEFT HAND
LIN LINOLEUM
LP LOW POINT
LT LIGHT
LTWT LIGHTWEIGHT
LVT LUXURY VINYL TILE
MACH MACHINE
MARB MARBLE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MB MARKER BOARD
MCM METAL COMPOSITE MATERIAL
MECH MECHANICAL
MES METAL EDGE STRIP
MEZZ MEZZANINE
MFR MANUFACTURER / MANUFACTURED
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MPC METAL PANEL CEILING
MSS METAL SUSPENSION SYSTEM
MTL METAL
MW MILLWORK
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NSMF NON-STRUCTURAL METAL FRAMING
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED - CONTRACTOR INSTALLED
OFF OFFICE
OFOI OWNER FURNISHED - OWNER INSTALLED
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
ORD OVERFLOW ROOF DRAIN
PBD PARTICLE BOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCONC POLISHED CONCRETE
PERF PERFORATE(D)
PL PLATE
PLP PLASTIC PANEL
PLAM PLASTIC LAMINATE
PLYWD PLYWOOD
PREFAB PREFABRICATED
PREFIN PREFINISHED
PRT POLY RESIN TILE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PLSHD POLISHED
PMT PORCELAIN MOSAIC TILE
PNT PAINT(ED)
PT PORCELAIN TILE
PTB PORCELAIN TILE BASE
QT QUARRY TILE
QTB QUARRY TILE BASE
QTY QUANTITY
R RISER
RAD RADIUS
RAF RESILIENT ATHLETIC FLOORING
RBF RUBBER FLOORING
RBRT RUBBER TILE
RCP REFLECTED CLG PLAN
RD ROOF DRAIN
REF REFER TO / REFERENCE TO
REFG REFRIGERATOR
REINF REINFORCED / REINFORCING
REQD REQUIRED
RES RESILIENT
RESB RESILIENT BASE
REV REVISE / REVISION
RF RESINOUS FLOORING
RFG ROOFING
RH RIGHT HAND
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
RSN RESILIENT STAIR NOSING
RST RESILIENT STAIR TREAD
RT RESILIENT TILE
RTU ROOF TOP UNIT
RV RIGID VINYL
S SEALED
SDF STATIC DISSIPATIVE FLOORING
SECT SECTION
SGT STRUCTURAL GLAZED TILE
SHR SHOWER
SHT SHEET
SIM SIMILAR
SM SPECIALIZED METAL
SOG SLAB-ON-GRADE
SP SAFETY PAD
SPEC SPECIFY / SPECIFICATION
SQ SQUARE
SS SOLID SURFACE / SURFACING
SST STAINLESS STEEL
ST STONE
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURE / STRUCTURAL
SUSP SUSPENDED
SV SHEET VINYL
SVT SOLID VINYL TILE
SWC SPECIAL WALL COATING
SWP SHEET WALL PROTECTION
T TREAD
TB TACK BOARD
TBD TO BE DETERMINED
TEMP TEMPORARY
TER TERRAZZO
TERB TERRAZZO BASE
TEXT TEXTURE
THK THICK(NESS)
TLT TOILET
TOS TOP OF STEEL
TOW TOP OF WALL
TP TANGENT POINT
TS TACKABLE SURFACE
TRSLT TRANSLUCENT
TYP TYPICAL
T&G TONGUE & GROOVE
UC UNDERCOUNTER
UPH UPHOLSTERY
UNO UNLESS NOTED OTHERWISE
VAC VACUUM
VCT VINYL COMPOSITION TILE
VEST VESTIBULE
VET VINYL ENHANCED TILE
VIF VERIFY IN FIELD
VNL VINYL
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
WAF WOOD ATHLETIC FLOORING
WC WATER CLOSET
WCV WALL COVERING
WD WOOD
WDWTR WINDOW TREATMENT
WP WORK POINT
WPC WOOD PANEL CEILING
WT WEIGHT
GENERAL NOTES_____________________________________________
1. ENCLOSE ALL EXPOSED DUCTS, PIPES, CONDUITS, ETC. IN FINISHED SPACE WITH CONSTRUCTION
AND FINISH TO MATCH ADJACENT CONSTRUCTION UNO.
2. PROVIDE ACCESS DOORS OF APPROPRIATE SIZE, TYPE AND FIRE RATING FOR ALL CONCEALED ITEMS THAT REQUIRE ADJUSTMENT, MAINTENANCE, MONITORING, ETC. COORDINATE LOCATIONS
WITH ARCHITECT.
3. DO NOT DETERMINE DIMENSIONS AND SIZE OF THE GRAPHIC REPRESENTATIONS SHOWN ON THE DRAWINGS BY USING MEASURING DEVICES (DO NOT "SCALE"). RELY ON THE NUMERIC DIMENSIONS
SHOWN ON THE DRAWINGS FOR MEASUREMENT.
4. DIMENSIONS ARE TAKEN FROM CENTERLINE OF STRUCTURE, FACE OF CONCRETE OR FINISHED
FACE OF PARTITIONS UNO. SEE PARTITION TYPES SHEETS (A1000 SERIES) FOR PARTITION
THICKNESS AND MATERIALS.
5. CENTER ITEMS IN CEILING PANELS UNO.
6. REFER TO FINISH LEGEND FOR FINISH PLAN SYMBOLS.
ABBREVIATIONS______________________________________________
A101
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE REMOVED
NEW CONSTRUCTION
PLAN SYMBOLS_____________________________________________________
INTERIOR ELEVATION KEY TO MATERIAL
SIM
50S
IM
50 S
IM
A0402
SIM
A1
E101
E45
1125A
L10
RA-1
SA-1
WA-1
A0401
SIM
A0401
SIM
A0401
SIM
1/A101
SIM
LEVEL 02
118'-6"
9 '- 0"
TYPE MARK
STC TAG STC-45
N
1 / A101
1 / A101
A)
SIM
A0401
SIM
DESCRIPTION
EQ-1
EQUIPMENT DESCRIPTION
ADA
HANDICAPPED
CLEARANCES
FINISH TAG
P-3WALL FINISH TAG
C
CEILNG MICROPHONE M
WIRELESS AP
UNDER CABINET
LUMINAIRE
A/V PROJECTOR
PROJECTOR SCREEN
F
B
W
CLCENTERLINE
INDICATES AREAS NOT IN CONTRACT
EXIT LUMINAIRE
SPRINKLER HEAD
TRACK LIGHT
NURSE CALL DOME
LIGHT
IV / CURTAIN TRACK
N
WALL WASH
LUMINAIRE
STRIP LUMINAIRE
COVE LUMINAIRE
SURGICAL LIGHT/
EQUIPMENT BOOM
PENDANT
WALL MOUNT STRIP
WALL MOUNT STRIP
EARTH
GRAVEL OR
POROUS FILL
CONCRETE
MASONRY UNIT
BRICK STONE
CONCRETE OR
PRECAST
RIGID INSULATION
PLASTER AND
GYPSUM BOARD
FINISHED WOOD
WOOD BLOCKING
OR SHIMPLYWOOD
STEEL OR IRONALUMINUM
SPRAY INSULATION
CORE MATERIAL
SPRAY
FIREPROOFING
ACOUSTICAL
CEILING
WOOD FRAMING
FIBERGLASS/
SOLID SURFACE
MATERIAL
COMPRESSIBLE
FILLER
TERRAZZO
FIBROUS BLANKET
INSULATION
(GLASS FIBER AND
MINERAL WOOL)
HORIZONTAL VERTICAL
FIBROUS BOARD
INSULATION
(GLASS FIBER AND
MINERAL WOOL)
1100 Clark Avenue St. Louis, Missouri 63102
T: 314.241.6250 F: 314.241.2570
JACKSON, MS
CANNON DESIGN PROJECT NO. 03640.61
© CannonDesign 2017 - All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation.
JAN 12, 2018
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. of 81Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
COMMUNITY LIVING CENTER
RENOVATION
586-16-106SYMBOLS & ABBREVIATIONS
A0001
CN GP,BB
MATERIALS
PULL
PULL
PAPER
TOWEL
DISPENSER
SOAP
DISPENSER
PAPER
TOWEL
DISPENSERS
TOWEL DISPENSER AND
WASTE RECEPTACLE
FULL
LENGTH
MIRROR
ELECTRIC
HAND
DRYERS
ACCESSIBLE
COAT HOOK
TOWEL
BAR
CUP
DISPENSER
FEMININE
NAPKIN
DISPENSER
ELECTRIC
HAIR
DRYERS
FOLDING
SHELF
COAT
HOOK
DIAPER SHELF/
CHANGING TABLE
SOAP
DISPENSER
NOTE: ALL DIMENSIONS INCLUDE ALL OPERABLE LEVERS, INCLUDING COIN SLOTS
CONTROL
HEIGHT
WATER SUPPLY
(VACUUM BREAKER)
SHOWER SLIDE WITH
HAND HELD SHOWER
AND 60" HOSE
RECESSED
SOAP DISH
7"
1'-6"
3"
10"
FINISH TO FINISH
3'-0" MIN
CONTINUOUS TWO
WALL GRAB BAR
FOLDING SEAT
CURTAIN ROD
CONTROL WALL BACK WALL SEAT WALL
BASED ON STANDARDS:
1. 2010 ADAAG AS MODIFIED BY:
A. VA PG 18-13 (1/1/2017)
B. VA DETAIL SD102800-01 (DEC 2008)
FINISH TO FINISH
5'-0" MIN
NOTE: SHOWER HOSE VACUUM BREAKER SHALL BE LOCATED A MINIMUM OF 6" ABOVE HAND SPRAY AT UPPERMOST POSITION ON SLIDE BAR
WATER SUPPLY
(VACUUM BREAKER)
SHOWER SLIDE WITH HAND HELD
SHOWER AND 60" HOSE
RECESSED SOAP DISH
CURTAIN ROD
THERMOSTATIC
MIXING VALVE
NURSE CALL
CONTINUOUS THREE
WALL GRAB BAR
FINISH TO FINISH
4'-0" MIN
BACK WALL CONTROL WALL
7" 1'-5"
2'-6"
48" X 60" SHOWER36" X 36" SHOWER
CURTAIN ROD
THERMOSTATIC
MIXING VALVE
1'-6"
2'-6" A L
IG
N
10"
2'-0"
EQ EQ
M
IN
IM
U M
1' - 6" MAX
1' - 4" MIN
S
T A
N D
A R
D
A
C C
E S
S
IB
L E
GRAB BARS
TOILET PAPER
DISPENSER
WATER CLOSET
LOW HEIGHT
FLUSH VALVE
WALL MOUNTED TOILET WITH FIXED GRAB BARS
3'-4"
MIRROR
LAVATORY
8" MIN
M
IN
N O
N A
C C
E S
S
IB
L E
A C
C E
S S
IB
L E
M
A X
1'-3" MIN
SPOUT
OUTLET
EQUIPMENT
PERMITTED IN AREA
SHOWN DASHED
ELECTRIC WATER COOLER
"4
SHELF
MOP HOLDER
SERVICE
FAUCET AND
CONTROLS
MOP BASIN
JANITOR CLOSET
TO SPOUT
5" MAX
1'-3" MIN
SOAP DISPENSER
RECESSED TOILET SEAT
COVER DISPENSER
FEMININE NAPKIN
DISPOSAL
1'-0"2'-0"1'-0" 3'-6"
6" MAX
M A
X A
C C
E S
S
IB
L E
URINAL
PRIVACY
SCREEN
2'-0" MAX
/8
S
T A
N D
A R
D
CLEAR
2'-6"
SIDE
VIEW
FRONT
VIEW
FACE OF
WALL
LINE OF FINISHED
CEILING
ELONGATED RIM
FOR ACCESSIBLE
URINAL
1'-2" MIN
SIDE
VIEW
FRONT
VIEW
SIDE
VIEW
FRONT
VIEW
SIDE
VIEW
FRONT
VIEW
NOTE: ACCESSIBLE AND NON-ACCESSIBLE PLUMBING FIXTURES ARE INDICATED IN THE PLUMBING DRAWINGS. HEIGHTS INDICATED ARE TO TOP OF SEAT.
PERPENDICULAR WALL
OR PROJECTING ELEMENT 4" MAX PROJECTION
/4
/4
MIN
MIRROR
INSULATE EXPOSED WATER
AND DRAIN PIPES
DOTTED AREA
INDICATES SPACE
FOR ACCESSIBLE
KNEE AND TOE
CLEARANCE
6" MAX
S U
R F
A C
E
M
A X
T O
M
IR
R O
R
M
IN
TYP: DEPTH OF SINK BOWL
NO GREATER THAN 6 1/2"
8" MIN
11" MIN
1'-5" MIN
2' - 1" MAX
M A
X
A C
C E
S S
IB
L E
COAT ROD AND SHELF COAT HOOK STRIP
NOTE: CLOSET 4'-0" WIDE AND LESS: ALL COAT STORAGE (ROD AND SHELF)
TO BE MOUNTED PER ACCESSIBILITY REQUIREMENTS.
CLOSET GREATER THAN 4'-0" WIDE: 2'-0" LENGTH OF COAT STORAGE (ROD
AND SHELF) TO BE MOUNTED PER ACCESSIBILITY REQUIREMENTS.
SHELF
ROD
M A
X
"5
M
IN
S E
E E
X C
E P
T
IO
N
T Y
P
HALL LANTERNS
RAISED
BRAILLE
CHARACTERS
ON HOISTWAY
ENTRANCES
HALL CALL
BUTTON
ELEVATOR
CONTROL
PANEL
HIGHEST
CONTROL
LOWEST
CONTROL
EXCEPTION: 4' - 6" MAX HEIGHT
PERMITTED IF ELEVATOR IS SERVING
MORE THAN 16 OPENINGS
FIRE
EXTINGUISHER
WALL MOUNTED
CABINET
FIRE ALARM
PULL BOX
M A
X
IM
U M
M A
X
IM
U M
FIRE
EXTINGUISHE
R WALL HUNG
FIRE
EXTINGUISHER
IN RECESSED
CABINET
FIRE EXTINGUISHER
AND FIRE HOSE
VALVE IN RECESSED
CABINET
FIRE DEPARTMENT
VALVE IN
RECESSED CABINET
FIREFIGHTER'S
HANDSET
FH
10 1/2"
M
IN
IM
U M
M
A X
MEN
CORRESPONDING GRADE II BRAILLE.
1/10" WITHIN CELL. 2/10" BETWEEN
CELLS, 1/40" MIN. RAISE ABOVE THE
BACKGROUND. LOCATED 3/8" MIN.
BELOW TACTILE CHARACTERS
WALL MOUNTED SIGNAGE TO BE LOCATED ON LATCH SIDE OF DOOR, CLEAR OF DOOR SWING.
TACTILE CHARACTERS SHALL BE CENTERED ON A MIN 18"X18" AREA LOCATED OUTSIDE THE ARC SWING OF THE DOOR. BRAILLE SHALL COMPLY WITH ADAAG 703.3.1, 703.3.2, FIGURE 703.31, AND
TABLE 703.3.1
WOMEN
AREA OF
RESCUE
ASSISTANCE
ELEVATOR
H
IG
H E
S T
L
IN
E O
F T
E X
T
-0
M
A X
T O
B O
T T
O M
O F
O F
L O
W E
S T
L
IN
E O
F
M
IN
T O
B O
T T
O M
T A
C T
IL
E
C H
A R
A C
T E
R S
T A
C T
IL
E
C H
A R
A C
T E
R S
8" 8"7
AUDIO/VISUAL
FIRE ALARM
EXIT SIGN WALL
SWITCH
WALL
PHONE
JACK
FIRE ALARM PULL
STATION
(GENERALLY
LOCATE UNDER
A/V ALARM)
W
IT
H O
W N
E R
C O
O R
D
IN
A T
E8"
COMBINATION
POWER/SIGNAL/OUTLET
FOR WALL MOUNTED
TELEVISION OR
MONITOR
CLOCK
(PLACED ON WALL
WITH NO VISUAL
BOARDS MOUNTED
BELOW)
DOUBLE-SIDED
PROJECTED
CLOCK
M
IN
C E
IL
IN
G H
E I G
H T
U
.N .O
S
P A
C E
S W
IT
H
T.V./DATA/
PHONE
POWER
RECEPTACLES
LIGHT
SWITCHES
DOME
LIGHT
OCCUPANCY
SENSOR
CARD
READER
THERMOSTAT
" 5
POWER
DISCONNECT
REMOTE DOOR
RELEASE
"5
TYPICAL CASEWORK
ASSEMBLY
TYPICAL
WORKSTATION
ASSEMBLY
WALL MOUNTED
FOLD DOWN
COMPUTER STATION
NIGHT
LIGHT
CLEAR
2'-6"
E
E
D/V
EM
E D/V
AREA OF
REFUGE
INTERCOM
4" MAX
FS E/C
SW SW
E
E OS CRP T DR E
DL
D
D
TV E/C
M
IN
C L
E A
R
LOCATE
SIGN ON
LATCH SIDE
OF DOOR
9"
SIGN
NOTE: SPACE SIGNGAGE
(1 PER EA. NUMBERED ROOM, TYP)
TO BE PROVIDED / INSTALLED BY
CONTRACTOR.
1100 Clark Avenue St. Louis, Missouri 63102
T: 314.241.6250 F: 314.241.2570
JACKSON, MS
CANNON DESIGN PROJECT NO. 03640.61
© CannonDesign 2017 - All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation.
JAN 12, 2018
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. of 81Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
COMMUNITY LIVING CENTER
RENOVATION
586-16-106ARCHITECTURAL EQUIPMENT &
MOUNTING INFORMATION
A0002
CN GP,BB
EQUIPMENT AND ACCESSORIES
ACCESSIBLE SHOWERS
ACCESSORIES AND PLUMBING
COAT HANGINGELEVATOR CONTROLS FIRE PROTECTION EQUIPMENT
CODE SIGNAGE ADA DETAILS
ELECTRICAL CONTROL DEVICES
SPACE SIGNAGE
ARCHITECTURAL EQUIPMENT SCHEDULE
ID ITEM Comments
AR-01 FIRE EXTINGUISHER CABINET
AR-02 PRIVACY CURTAIN & TRACK
AR-03 MED GAS WALL BOX - RECESSED, 3 GAS, W/ SHIFTABLE WALL ART.
AR-04 ROLLER SHADE - SINGLE MANUAL
AR-05 P-TUBE STATION, RE: 12/A0800
AR-06 LOCKER, DOUBLE TIER - ASI STORAGE SOLUTIONS (SKY BLUE)
AR-07 LOCKER, SINGLE TIER
AR-08 MOP/BROOM HOLDER, JANITORIAL
AR-09 CLOCK, WALL (NIC)
AR-10 WASTE, STEP ON (NIC)
AR-11 CART, COMPUTER, (COW, COMPUTER ON WHEELS)
AR-12 CART, MEDICINE (NIC)
AR-13 CART, SOILED LINEN (NIC)
AR-14 REFRIGERATOR, CLINICAL
AR-15 PATIENT LIFT, CEILING MOUNTED
AR-16 Printer/Copier
AR-17 CART, RESUSCITATION (CRASH CART), ADULT
AR-20 NURSE CALL STATION, RE: ELECT DWGS
AR-21 NURSE CALL PULL CORD - SHOWER, RE: ELECT DWGS
AR-22 NURSE CALL PULL CORD - TOILET, RE: ELECT DWGS
AR-30 CABINET, MEDICINE STORAGE
AR-30L CABINET, MEDICINE STORAGE - LOCKABLE
AR-40 TELEVISION, 32" FLAT PANEL (NIC)
AR-50 OVEN, SIDE OPENING MFR'S BUILT-IN KIT
AR-51 DISHWASHER, KITCHEN
AR-52 COOK TOP, 4-UNIT
AR-53 MICROWAVE OVEN, SIDE OPENING MFR'S BUILT-IN KIT
AR-54 MICROWAVE, COUNTERTOP
AR-55 ICE MAKER, COUNTER
AR-56 ICE MAKER, FREESTANDING
AR-57 REFRIGERATOR, FRENCH DOOR - COUNTER DEPTH
AR-58 REFRIGERATOR, TOP FREEZER
AR-59 STORAGE RACK, MEDICAL GAS CANISTER
AR-60 WASHER/DRYER, STACKED (EXISTING TO BE RELOCATED)
TOILET ACCESSORY SCHEDULE
ID ITEM (SPEC SECTION 102800 UON)
TA-01 088300 - WALL MIRROR - 24W x 48H
TA-02 SHOWER CURTAIN ROD - SWING CLEAR GATE TYPE
TA-02A CURTAIN ROD, SHOWER
TA-03 ROBE HOOK
TA-04 GRAB BAR, 48"
TA-05 GRAB BAR, 18" (VERTICAL MOUNTING)
TA-06 GRAB BAR, 36"
TA-07 GRAB BAR, 42"
TA-08 GRAB BAR, 18" x 30" L CONTINUOUS
TA-09 GRAB BAR, 18"
TA-10 DISPENSER, TOILET PAPER
TA-11 DISPOSAL, FEMININE PRODUCT
TA-12 DISPENSER, SEAT COVER
TA-13 DISPENSER, PAPER TOWEL (BY OWNER)
TA-14 DISPENSER, SOAP (BY OWNER)
TA-15 102800 - SOAP DISH, RECESSED
TA-16 GRAB BAR, FLIP-UP
TA-17 GRAB BAR, 18"
TA-18 SS SHELF
TA-19 088300 - WALL MIRROR - 24W x 72H
TA-20 102800 - SHOWER SEAT - WALL
TA-21 SHOWER SEAT - MOBILE (BY OWNER)
Signage - Facility Wayfinding V O V not in contract
Signage - Rooms V C V in GC contract
Signage - Code Required V C V in GC contract
Wayfinding
Washer / Dryer CD C C See alternates
Undercounter Refrigerator CD C C See alternates
Refrigerator Freezer - Non-Clinical CD C C See alternates
Microwave CD C C See alternates
Ice Maker/Dispenser - Rough-In CD C C See alternates
Ice Maker/Dispenser - Countertop CD C C See alternates
Ice Maker/Dispenser - Floor Model CD C C See alternates
Dishwasher Rough-In CD C C To remain in contract even if alternate is accepted
Dishwasher CD C C See alternates
Coffee Maker O O O
Nourishment Equipment
Pneumatic Tube System V C V See alternates
Lockers CD C C
Medical gas canister rack CD C C
Miscellaneous Equipment
Window Treatments CD C C
Seating - Chairs/Sofas/guest chairs/task seating O O O
Patient Room Furniture (excludes beds) O O O
Office Furniture O O O
Lobby/Waiting Room Furniture O O O
Custom Design Casework CD C C
Conference Room - Table/Seating O O O
Patient Room Bulletin / Magnetic White Boards CD C C
General Bulletin / Magnetic White Boards CD C C
Artwork O O O
Furnishings
Extinguishers CD C C
Extinguisher Cabinets CD C C
Fire Prevention Equipment
Existing Medical Equipment Relocation O X O
Existing Medical Equipment Tagging O X O
Existing Medical Equipment Inventory O X O
Equipment (Medical Equipment)
- Existing - including those existing items listed above
Sharps Containers - Wall Mounted O O C
Patient Lifts - Ceiling Mounted Rough-In CD C C To remain in contract even if alternate is accepted
Patient Lifts - Ceiling Mounted V C V See alternates
Medication Dispensing Units CD O O
Medical Gas Outlets - Recessed/Casework CD C C
Medical Gas - Flowmeters/Regulators CD C C
Linen Hamper NA O O
Glove Box Dispenser- Wall Mounted O O O
Defibrillators CD O O
Carts - Linen NA O O
Carts - Housekeeping CD O O
Carts - Crash Adult/Pediatric CD O O
Carts - Clinical Supply O O O
Cabinets - Medicine Storage (lockable and non-lockable) CD C C
Equipment (Medical Equipment)
Waste Receptacle- Built-in CD C C
Towel Bar CD C C
Toilet Paper Dispenser CD O C Shown on drawings for location only
Soap Dispenser/ Hand Gel CD O C Shown on drawings for location only
Shower Curtain Rod CD C C
Shower Curtain CD C C
Shelf - Patient Toilet Room CD C C
Paper Towel Dispenser CD O C Shown on drawings for location only
Mop & Broom Holder CD C C
Mirrors CD C C
Kick Plates CD C C
Hand Sanitizer Dispenser, Wall-mounted O O C
Grab Bars CD C C
Corner Guards/ Bumper Rails/Handrails CD C C Coordinate finish/specs w/ Interior Designer
Coat Hook CD C C Patient rooms & offices
Cubicle Curtain Track CD C C Bath Suite and patient rooms
Cubicle Curtains O O O Bath Suite and patient rooms
Baby Changing Station - Public Restrooms CD O C Shown on drawings for location only
Accessories
ITEM Designed By Procured By Installed By COMMENTS
C Contractor NA Not applicable or system is not being provided
V By others / vendor CC Cannon Design Consultant
O By others / owner CD Cannon Design
Abbreviations:
FFE RESPONSIBILITY MATRIX
UPUP
UPUP
DN
DNUP
UP
Bedroom
G148
SIM.G165
Bedroom
G149
SIM.G165
Bedroom
G150
SIM.G165
Bedroom
G151
SIM.G165
Bedroom
G152
SIM.G165
Bedroom
G153
SIM.G165
Bedroom
G142
SIM.G165
Bedroom
G143
SIM.G165
Bedroom
G144
SIM.G165
Bedroom
G145
SIM.G165
Bedroom
G146
SIM.G165
Bedroom, Bariatric
G141
SIM.G161
Bath Suite
G154
Bedroom, Bariatric
G161
Soiled Utility
G174
Clean Utility
G173
Bedroom
G172
SIM.G165
Bedroom
G171
SIM.G165
Bedroom
G170
SIM.G165
Bedroom
G169
SIM.G165
Bedroom
G168
SIM.G165
Bedroom
G166
SIM.G165
Bedroom
G165
Bedroom
G164
SIM.G165
Bedroom
G163
SIM.G165
Bedroom
G162
SIM.G165
Office
G123
Family Lounge
G107
Medicine Storage
G106
Telecom Closet
G113
Conference
G131 Staff Lounge
G126
Office
G127
Office
G128
Mechanical (E)
G132
Mechanical (E)
G132.1
Concierge Station
G105
Sitting Area
G104
Multi-Purpose Area
G112
Laundry
G109
Shared Office
G129
Toilet
G148.1
SIM.G165.1
Toilet
G149.1
SIM.G165.1
Toilet
G150.1
SIM.G165.1
Toilet
G151.1
SIM.G165.1
Toilet
G152.1
SIM.G165.1
Toilet
G153.1
SIM.G165.1
Toilet
G146.1
SIM.G165.1
Toilet
G145.1
SIM.G165.1
Toilet
G144.1
SIM.G165.1
Toilet
G143.1
SIM.G165.1
Toilet
G142.1
SIM.G165.1
Toilet
G141.1
SIM.G161.1
Toilet
G166.1
SIM.G165.1
Toilet
G165.1
Toilet
G164.1
SIM.G165.1
Toilet
G163.1
SIM.G165.1
Toilet
G162 SIM.G165.1Toilet
G161.1
Storage
G140.1
Corridor
G140 Corridor
G160
Stairs
G167 Stairs
G147
Stairs
G133
Lobby
G103
Oxygen Storage- Empty
G121
Storage
G140.2
Elec
G160.2 Storage
G160.4
Alcove
G160.5
Toilet
G172.1 SIM.G165.1 Toilet
G171.1
SIM.G165.1
Toilet
G170.1
SIM.G165.1
Toilet
G169.1
SIM.G165.1
Toilet
G168.1
SIM.G165.1
A
A
B
B
C
C
D
D E
F
F G
H
J
K
M
N
O
P
P
R
S
T
T
U
U
V
V
W
W
PROJECT LIMIT LINE
Foyer
G101
Lobby
G103
Vestibule
G100
Elevator
C1-G
Elevator
C2-G
EXISTING FITNESS CENTER
(TO BE REPLACED BEFORE PROJECT BEGINS)
Locker Room
G130
Toilet
G130.2
Toilet
G130.1
Elec
G120.1
Storage/Linen Storage
G110
Kitchen
G111
House Keeping
G122
Alcove
G140.5Elec Closet
G140.4
Storage
G140.3
Storage
G160.3
Office
G124
Multi-Purpose Area
G102
A0201
A0201
A0201
A0201
A0201
A0201
A0601
A0601
A0601
A0601
A060118
X167
X133.1
X132
X
.1
G
G
.2
G
.1
G
.2
G
.4
G
G
G174
G110
G109
G
.3
G124
G126
G127
G128
G130
G129
G131
G
.1
G130.2
G
G120.1
X006
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G148.1 G149.1 G150.1 G152.1G151.1 G153.1
G145.1G146.1 G144.1 G143.1 G142.1 G141.1
G172.1 G171.1 G170.1 G168.1G169.1
G163.1G161.1 G164.1 G166.1G165.1
X004
G121
G
G
G
V008
X007
X133
G140
X
X010
G100
X002
X003
A0201
A6
R4
A4.1
R4
R6
A4
A4A4
R6
A4
A4
A4
A4
R6
R6
G4
R5 A4.1
A6.1
L4
A4.1
A4
R4
R4
R4
H5.1
A6.1
R4
A4
A0201
P3
R4
R4
R4
R4 R4
R4 R4
R4
A060210
X2
X2
X2
R6
X2
X2
16'-6" 4'-1 1/8" 11'-3 1/4" 13'-8 3/4" 3'-1 1/4" 16'-3" 5'-7 3/4" 9'-10 1/2" 2'-0" 12'-10 3/4"
1'-11 1/2"
13'-9 1/4"
13'-2" 3'-9 1/8" 4'-6 1/2" 11'-10 1/4"
6'-4 3/8"
8'-0 1/4" +/- 22'-3 1/2"
P3
(EXISTING)
MAIN HOSPITAL
R6
X1
X1
A6.1
Oxygen Storage - Full
G121.1
AR-14
AR-12AR-12
H5
A4
R4
Public Toilet
G108
G108
EQ-03
EQ-03
M6
R3
AR-05
A0800
TYP
A0800
TYP
R4 R4
R4
R4 R4
M6
Corridor
G175
G162.1
A4
L
3 4
AR-60
Office
G125 G125
G
.9
R4
P3
A6.1
42" TALL
PARTITION
A4.1
L4
R4 R4
A0601
G160
A4.1
G132
A0800
A6
P3
R6
U5U5
L4
R4
11"
R6
R4
R3 R4
R4
R4
R4
U6
A4
A0201
U6
AR-01
U6 U6
U6
U6
R3
R4 U6
R4
R6
X2
E2
R4 R4
L4
L4
P3
P3
5'-0"
R4
L4
L4 R4
R4
R4
EWC
AR-01
R4
R4
R4
R3
R4 U6
U6
R4
A6.1
R6
R4
A0601
P R
O J E
C T
L
IM
IT
L
IN
E
AR-01
AR-01 AR-01
AR-30L
9 7/8"
4/A0800
TYP
TYP
R6
E2
R6 1'-6" 1'-0"
6 1/4"
EQ EQ
R6
R4R4
U5
R6
R6
R4R4 U5
U6
R3
R4
R6
R4
R4 R4 R4
R4
R4
E2
R4
R4
R4
R6 U5
R6
R6
R4
R3
R4
R4 R4
R4
R3
R4
R4R4 U5
R4
U6
R4 R4
R6 U5U5R6
R4
R4
A0601
SIM
AR-01
/4
/2
/8
EQ EQ
EQ EQ
12'-1 1/2" 3'-4 1/8" 15'-9 7/8" 5'-10" 9'-10 1/2" 14'-9 3/4"
3 3/4"
11'-10 1/2" 2'-10" 12'-0" 11'-5" 4 1/8" 18'-6 3/8" 5'-3" 3" 12'-8 7/8" 3'-11 5/8" 19'-6 1/4" 3 3/4"
10'-11 1/2" 12'-6 3/4" 2'-8 3/4"
11'-10 1/2" 10 3/8"
15'-2 1/8" 8'-11 1/2" 6'-0" 15'-11 1/8" 3'-1" 11'-10 5/8"
H5
R4
8'-10 1/4" 9'-3" 1'-6 3/4" 11'-0 3/4" 13'-4 1/4"
1'-10 7/8"
11'-9 5/8" 6'-4 7/8" 14'-9 1/2" 3'-9 5/8" 11'-6" 13'-6" 4'-11 5/8" 15'-2 3/8"
/8
/8
/4
/8
/8
/4
R4
1'-2 1/4" 10'-2" 5'-0" 6'-11" 1'-5"
/8
/2
/4
/2
/8
A0601 2 S
IM
G4
R4
R4
R6
R4
R2
R2
/2
H5
A4
H5
R4
L1
A4.1R4 U6
G4
R4R6 U6
U6 R4 R4
U6
R4 R4
R4
EQ EQ
R6
R6
U6
U6 U6
U6
U6 R4
R6R6
U6
A L
IG
N
A0602
HATCHED ROOMS - REFER TO TYPICALS
HATCHED ROOMS -
REFER TO TYPICALS
HATCHED ROOMS -
REFER TO TYPICALS
HATCHED ROOMS -
REFER TO TYPICALS
T Y
P
/8
R4
R4R4R4
R4
R4
H5
AR-59 AR-59
G113
G
Closet
G114
R3
R3
G114
L4
A060117
AR-17
E2 E2
GENERAL NOTES:
1. ALL EXTERIOR WALLS TO BE PROVIDED WITH FULL-HEIGHT TYPE
'E2' PARTITION, TYP. UNO.
2. ALL PARTITION TAGS AND DIMENSIONS ON THIS SHEET TAKE
PRIORITY OVER TAGS THAT ARE NOTED OTHERWISE OR TYP. ON
SHEET A0201.
3. ALL CONCRETE CORING THROUGH SLAB SHALL HAVE THE SLAB X-
RAY SCANNED AND THE LOCATION VERIFIED ON A CASE-BY-CASE
BAISIS BY THE STRUCTURAL ENGINEER PRIOR TO SLAB CORING.
IF THE LOCATION IS FOUND TO BE UNACCEPTABLE, THE LOCATION
SHALL BE REVISED.
1100 Clark Avenue St. Louis, Missouri 63102
T: 314.241.6250 F: 314.241.2570
JACKSON, MS
CANNON DESIGN PROJECT NO. 03640.61
© CannonDesign 2017 - All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation.
JAN 12, 2018
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. of 81Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
COMMUNITY LIVING CENTER
RENOVATION
586-16-106GROUND FLOOR PLAN
A0101
CN GP,BB
1/8" = 1'-0"
GROUND FLOOR OVERALL PLAN
Floor Plan Keyed Notes Number Description
1 NEW EXTERIOR STOREFRONT AND DOOR ON AUTOMATIC OPERATOR.
2 12x16 WIND-DRIVEN RAIN EXHAUST LOUVER, COORDINATE EXACT
PLACEMENT WITH ARCHITECT
3 NEW EXTERIOR STOREFRONT - SIM. EXISTING
4 REPAIR AND REPLACE CRACKED SPANDEL PANEL AS NEEDED.
B N
T L
T -0
TLT-01
D W
REF.
TLT-01
A0601 4 3
A0601
5'-1" 2'-11"
Bedroom
G165
Toilet
G165.1
/2
R4
R4
R4
U6
TA-09
TA-03
TA-10
TA-06
TA-02
AR-03
G165
G165.1
E2
AR-21
AR-22
AR-40
A1002
4/A0800
TYP
AR-30L
AR-02
TA-06
R4
R4
/8
T
Y P
TYP.
2'-1"
VARIES (6'-0" MIN.)
3'-6"
RE: FOR
SLOPE TO DRAIN PLAN
1 / A0811
A0800
TYP
U6
R4
AR-30
AR-30
/8
A0901
F H
A060115
Bath Suite
G154
6'-1 3/8" 8'-4 7/8"
BATH TUB, ASSISTED
(EXISTING RELOCATED)
TA-09
G
ADD OBSCURING FILM TO WINDOW GLASS
4/A0800
TYP
A0800
TYP
AR-22
5'-6 3/8"
/4
/2
/8
1'-3"
TA-13
TA-14
U6
U6 H5.1
R4
TA-09
TA-10
TA-01
O P S
Toilet
G161.1
Bedroom, Bariatric
G161
A0602
/4
/8
5'-4 1/4" 5'-0" 11" 11" 2'-5 1/4" 4 5/8" 5'-0" 3'-2 5/8"
R4
H5.1
R4
TA-03
TA-09
TA-06
TA-02
G161.1
G
AR-03
A0800
U6
AR-30L
AR-30
R4
H5.1 AR-22
AR-40
U6U6
U6
RE: FOR
FLOOR SLOPE TO DRAIN
1 / A0811
E2
E2
R4R4 R4
3'-6"
A0601
SIM
A0602
A0800
SIM
6"
AR-02
E Q
E Q
K N
A06022
G130.1
G130.2
G129
Shared Office
G129
Toilet
G130.1
Toilet
G130.2
Locker Room
G130
TA-13
TA-14
TA-14
TA-13
AR-06
AR-06
G130
R5
HOLD
5'-0"
TA-10
TA-11
TA-05
TA-06
FD
TA-12
TA-12
TA-11
TA-10
TA-05
TA-07
TA-06
TA-07
R6
3'-1" 1'-5"
TA-08
TA-02A
TA-09
R4
R4
R4
R4
TA-01
TA-01
TA-03
TA-03
O P
A06019
Kitchen
G111
A4.1
AR-50AR-53 AR-52
AR-51
R6
R3
A4R4
/4
AR-57 AR-55
HOLD
6'-0 1/8"
H
A0602
2'-5"4'-3"
7'-1"
2'-3"
6'-8"
5"
A0602
A0602
SS-4 COUNTERTOP
& RETURNS
2"
EQ
Concierge Station
G105
AR-05
A1002
TYP
A L
IG
N
G
H5
H5
H5
/2
P3
P3
4'-4 3/4"
AR-16
10/A0902
11/A0902
H
A0601
Staff Lounge
G126
/4
/8
AR-54
AR-56
AR-58
G126E2
E2
4/A0800
TYP
A0800
TYP
3'-0" 5 1/8"
H
J
A060113
Family Lounge
G107
11'-2 1/4" 8'-1 1/4"
/8
/2
AR-54
AR-58
G107
AR-05
A1002
TYP
4/A0800
TYP
A0800
TYP
ALTERNATE LOCATION
OF P-TUBE STATION.
/8
A4R4
R4
G108
R4
H5H5
A4
TA-05
TA-07
TA-10
TA-11
TA-14
TA-13
TA-12
TA-06
1'-4"
P R
H5 A4
E2
/8
TA-13
TA-14
G174
G
310 3/8"
1'-6" 1'-6" 5'-3 1/2"
TA-14 TA-13
1'-3"
/2
2'-2"
U6
U6
Clean Utility
G173
Soiled Utility
G174
/2
/4
1100 Clark Avenue St. Louis, Missouri 63102
T: 314.241.6250 F: 314.241.2570
JACKSON, MS
CANNON DESIGN PROJECT NO. 03640.61
© CannonDesign 2017 - All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation.
JAN 12, 2018
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. of 81Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
COMMUNITY LIVING CENTER
RENOVATION
586-16-106ENGLARGED PLANS
A0201
CN GP,BB
1/4" = 1'-0"
RESIDENT ROOM G165 - ENLARGED PLAN
1/4" = 1'-0"
BATH SUITE
1/4" = 1'-0"
BARIATRIC BEDROOM G161 - ENLARGED PLAN
1/4" = 1'-0"
LOCKER ROOM
1/4" = 1'-0"
KITCHEN
1/4" = 1'-0"
CONCIERGE STATION
1/4" = 1'-0"
STAFF LOUNGE
1/4" = 1'-0"
FAMILY LOUNGE
1/4" = 1'-0"
PUBLIC TOILET
1/4" = 1'-0"
SOILED / CLEAN ROOMS
FD
GENERAL NOTE:
1. ALL PARTITION TAGS AND DIMENSIONS ON THIS SHEET ARE
TYPICAL UNLESS NOTED OTHERWISE ON SHEET A0101.
GENERAL NOTES - INTERIOR
1. ALL DIMENSIONS ARE FINISH DIMENSIONS UNLESS OTHERWISE
NOTED.
2. ALL DIMENSIONS FOR CASEWORK AND MILLWORK ARE TO BE
FIELD MEASURED AND VERIFIED BEFORE FABRICATION BEGINS.
3. ALL BASES TO BE 4" HIGH RESILIENT BASE UNLESS OTHERWISE
NOTED. REFER TO THE ROOM FINISH FOR ALL FINISHES.
4. ALL SOAP DISPENSERS AND PAPER TOWEL DISPENSERS
SHOWN ARE TO BE FURNISHED BY THE OWNER AND
INSTALLED BY THE CONTRACTOR.
5. TYPICAL SWITCH AND RECEPTACLE LOCATIONS MAY BE
INDICATED AT INTERIOR ELEVATIONS, BUT DO NOT REPRESENT
TOTAL QUANTITIES OR INDIVIDUAL TYPES, AT THESE
LOCATIONS ONLY, REFER TO MOUNTING HEIGHT
REQUIREMENTS. SEE MECHANICAL AND ELECTRICAL
DRAWINGS FOR COMPREHENSIVE FIXTURE AND/OR DEVICE
QUANTITIES AND LOCATIONS.
6. ALL RECEPTACLES AND OUTLETS BELOW COUNTER HEIGHT
ARE TO BE MOUNTED 18" AFF TO CENTERLINE OF DEVICE
UNLESS OTHERWISE NOTED.
7. ALL RECEPTACLES AND OUTLETS ABOVE COUNTER HEIGHT
ARE TO BE MOUNTED 6" ABOVE TOP OF COUNTER OR 6"
ABOVEBACKSPLASH (WHERE OCCURS) TO CENTERLINE OF
DEVICE UNLESS OTHERWISE NOTED.
TA-13 TA-14
TA-01
SS-3 END
PANEL
AR-22
2'-0"
TA-10
801.1
SS-3
2'-1"
TA-16
TA-17
4'-3 1/4"
AR-34
4/A0902
TYP
VNL-1
4'-0"
VNL-1
4'-0"
AR-34
VNL-1
2'-0"
VNL-1
2'-0"
VNL-1
2'-6"
VNL-1
2'-0"
VNL-1
2'-0"
CT-4
SS-4
AR-55
CABINET SOFFIT TO CEILING
AR-57
REMOVABLE SOFIT PANEL
WITH LOCK3" MIN.3" MIN.
3" VENTILATION
CLEANCE ALL
SIDES
VNL-1
4'-0"
VNL-1
2'-0"
AR-51
VNL-1
2'-0"
VNL-1
2'-0"
VNL-1
2'-0"
VNL-1
1'-6"
VNL-1
1'-6"
CABINET SOFFIT TO CEILING
CT-4
SS-4
HOOD - RE
MECH.
VNL-1
1'-0 7/8"
VNL-1
3'-0"
VNL-1
1'-3"
SS-4
(LOBBY BEYOND)
2/A0903
1"
VNL-1
3'-0"
VNL-1
3'-0"
VNL-1
2'-6"
VNL-1
2'-6"
VNL-1
1'-6"
VNL-1
1'-6"
VNL-1
2'-0"
VNL-1
2'-0"
402.5
VNL-1
2'-6"
VNL-1
1'-6"
VNL-1
1'-6"
440.1
VNL-1
3'-7 1/2"
VNL-1
2'-0"
CT-4
SS-4 RETURN
CABINET SOFFIT TO CEILING
AR-53
AR-50 AR-52
HOOD - RE: MECH.
402.5
VNL-1
2'-6"
VNL-1
1'-0"
SS-4
VNL-1
2'-0"
1/A0903
1"
SS-3
3'-8"
VNL-2
3'-0"
VNL-2
3'-0"
VNL-2
1'-6"
VNL-2
1'-7"
AR-58
AR…