36C25219B0038-006.pdf
PDF 15 MB Posted
- Attached to
- 556-305, Construct New Parking Garage Federal contract opportunity
- Solicitation number
- 36C25219B0038
About this file
36C25219B0038 Bid Documents Drawings Part 2 of 2 2-20-20 - Copy.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25219B0038-0007001.pdf | ||
| 36C25219B0038-0007000.docx | DOCX document | |
| 36C25219B0038-0006000.docx | DOCX document | |
| 36C25219B0038-0005000.docx | DOCX document | |
| 36C25219B0038-0005001.pdf | ||
| 36C25219B0038-0005002.pdf | ||
| 36C25219B0038-0004000.docx | DOCX document | |
| 36C25219B0038-0003005.pdf | ||
| 36C25219B0038-0003008.pdf | ||
| 36C25219B0038-0003002.pdf | ||
| 36C25219B0038-0003001.pdf | ||
| 36C25219B0038-0003009.pdf | ||
| 36C25219B0038-0003010.pdf | ||
| 36C25219B0038-0003000.docx | DOCX document | |
| 36C25219B0038-0003007.pdf | ||
| 36C25219B0038-0003003.pdf | ||
| 36C25219B0038-0003004.pdf | ||
| 36C25219B0038-0003006.pdf | ||
| 36C25219B0038-0002000.docx | DOCX document | |
| 36C25219B0038-0001001.pdf | ||
| 36C25219B0038-0001000.docx | DOCX document | |
| 36C25219B0038-003.pdf | ||
| 36C25219B0038-005.pdf | ||
| 36C25219B0038-004.pdf | ||
| 36C25219B0038-001.docx | DOCX document | |
| 36C25219B0038-002.pdf | ||
| 36C25219B0038-000.docx | DOCX document |
Show all 27
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TOS EL
REFER TO PLAN
TOF EL
REFER TO PLAN
TOS EL
REFER TO CIVIL
1.2
1/2" COMPRESSIBLE
FILLER W / SEALANT TYP
CIVIL SITE SLAB
WATERPROOFING
MEMBRANE SYSTEM
WATERPROOFING MEMBRANE SYSTEM
MAT FOUNDATION, REFER TO PLAN
WATERSTOP
WATERSTOP
WATERSTOP
#4 @ 9" OC EF
#4 @ 9" OC EF
4" PERFORATED FDN DRAIN
SLOPE AT 0.5% MIN REFER
TO CIVIL FOR CONTINUATION
4'-0"
4' -0
"4# @ 12" OC
(2) #4
#4 @ 15" OC EF
#4 @ 15" OC EF
ELEVATOR PIT
COVE SEALANT
8" CMU WALL W/ #5 @ 16" OC VERT
1' -1
3/
8"
8" 2"
6"
#6 @ 12" OC T&B, EW
PCC WALL PANEL
TOW EL
REFER TO PLAN
CONN BY PCC MFR,
REFER TO DET
1/SF532
2" 8"
SF561
7"
GALV HSS
DIVIDER BEAM
REFER TO
DET 7/SF551
LA
P
S P
LI
C
E
2' -6
TOS EL
REFER TO PLAN
TOF EL
REFER TO PLAN
TOS EL
REFER TO CIVIL
A.A A.1
1/2" COMPRESSIBLE
FILLER W / SEALANT TYP
CIVIL SITE SLAB
WATERPROOFING
MEMBRANE SYSTEM
WATERPROOFING MEMBRANE SYSTEM
MAT FOUNDATION, REFER TO PLAN
WATERSTOP
WATERSTOP
WATERSTOP
#4 @ 9" OC EF
#4 @ 9" OC EF
LA
P
S P
A C
E
C
LA
S S
B
4'-0"
4' -0
"4# @ 12" OC
7"
(2) #4
#4 @ 15" OC EF
#4 @ 15" OC EF
ELEVATOR PIT
COVE SEALANT
PCC WALL PANEL
REFER TO
DET 5/SF551
#6 @ 12" OC T&B, EW
3' -0
8" 2" 2"
1'-0"
CONN BY PCC MFR,
REFER TO DET
1/SF532
2 1/8" 8"
PCC WALL PANEL
TOW EL
REFER TO PLAN
CONN BY PCC MFR,
REFER TO DET
1/SF532
4" PERFORATED FDN DRAIN
SLOPE AT 0.5% MIN REFER
TO CIVIL FOR CONTINUATION
1'-6" 1'-6"
1' -6
1'
-6
32" X 32" PCC COL
ABOVE
CIP WALL
#4 TIES AT 12" OC
(16) #9 VERT W/
STD HK IN MAT
FTG
NOTE: WALL REINF NOT SHOWN FOR
CLARITY. WALL REINF SHALL BE
CONTINUOUS THRU PILASTER. GC
TO INSTALL PCC COL ANCHOR
BOLTS SUPPLIED BY PCC MFR.
1'-0" 8" 1'-0"
1' -6
(4) #5 X CONT
REFER TO PLAN
TOW EL
REFER TO CIVIL
TO GRADE
REFER TO PLAN
TOS EL
8"
GLAZING, REFER TO ARCH
COVE SEALANT
CONC SOG
BOND BREAKER
REFER TO PLAN
TOF EL
#4 @ 6" OC W/
STD HOOKS
CONN BY PCC
MFR, REFER TO
DET 1/SF532
PCC WALL
PANEL
CIVIL SITE
SLAB
1/2" COMPRESSIBLE
FILLER W/ SEALANT
1'-0" 8" 1'-0"
1' -6
(4) #5 X CONT
REFER TO CIVIL
TO GRADE
REFER TO PLAN
TOS EL
8"
COVE SEALANT
CONC SOG
BOND BREAKER
REFER TO PLAN
TOF EL
#4 @ 6" OC W/
STD HOOKS
CONN BY PCC
MFR, REFER TO
DET 1/SF532
PCC WALL
PANEL
CIVIL SITE
SLAB
1/2" COMPRESSIBLE
FILLER W/ SEALANT
1'-0" 8" 1'-0"
1' -6
(4) #5 X CONT
REFER TO PLAN
TOS EL REFER TO PLAN
TOS EL
REFER TO PLAN
WASH 8"
COVE SEALANT
CONC SOG
BOND BREAKER
REFER TO PLAN
TOF EL
#4 @ 6" OC W/
STD HOOKS
PCC WALL
PANEL
CONC SOG
COVE SEALANT
CONN BY PCC
MFR, REFER TO
DET 1/SF532
8" 4" 1'-8"
1' -6
(4) #5 X CONT
REFER TO PLAN
TOS EL REFER TO PLAN
TOS EL
REFER TO PLAN
WASH 4" 8"
COVE SEALANT
CONC SOG
BOND BREAKER
REFER TO PLAN
TOF EL
#4 @ 6" OC W/
STD HOOKS
PCC WALL
PANEL
CONC SOG
COVE SEALANT
REFER TO PLAN
TOS EL
COVE SEALANT
CONN BY PCC MFR
PCC STAIRS W/
FIELD TOPPING
CONC DAM
8" MIN
BEARING PAD
HAUNCH
CONN BY PCC
MFR, REFER TO
DET 1/SF532
1'-0" 8" 1'-0"
1' -6
(4) #5 X CONT
REFER TO PLAN
TOS EL
COVE SEALANT
CONC SOG
BOND BREAKER
REFER TO PLAN
TOF EL
#4 @ 6" OC W/
STD HOOKS
8" CONC WALL W/
#5 @ 8" OC VERT &
#4 @ 12" OC HORIZ
LA
P
S P
LI
C
E
2' -6
8" CMU W/ #5 @ 16" OC GROUT
CORES SOLID AT REINF
GALV EMBED PLATE
1/2X10X10 W/ (4) 1/2" Ø
X 4" HSA
3/8" CAP PLATE WELDED TO TUBE
(2) 3/4" Ø A325 THRU BOLTS
(2) 3/8" CONNECTION
PLATE ONE ON EACH SIDE
OF TUBE
CONC WALL
1/4"
TOS EL
REFER TO PLAN
GALV HSS BEAM
SF561
GALV EMBED PLATE
1/2X10X10 W/ (4) 1/2" Ø
X 4" HSA
3/8" CAP PLATE WELDED TO TUBE
(2) 3/4" Ø A325 THRU BOLTS
GALV. HSS BEAM
(2) 3/8" CONNECTION
PLATE ONE ON EACH SIDE
OF TUBE
CONC WALL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
M/E/P Engineers: Structural Engineer:
Apogee Consulting Group, PA
1511 Kildaire Farm Road, Suite 120
Cary, NC 27511
(919) 858-7420
Carl Walker, a Division of WGI
8910 Purdue Road, Suite 400
Indianapolis, IN 46828
(317) 735-3349
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100
Indianapolis, IN 46204
(317) 800-6388
BID DOCUMENT
NOT SPRINKLERED
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
DPG DEB
D R e v it U s e r
F ile s \P
-2
-0
-C
W I-
V d a n .b ro w n L D
P W
Z .r v t
/7
/2
:0 :1
P
M
SF561
ENLARGED PLAN DETAILS -
STRUCTURAL
1/9/2019 41 OF 80
3/4" = 1'-0"
FOUNDATION WALL DETAIL
3/4" = 1'-0"
FOUNDATION WALL DETAIL
3/4" = 1'-0"
PILASTER DETAIL
3/4" = 1'-0"
WALL DETAIL
3/4" = 1'-0"
WALL DETAIL
3/4" = 1'-0"
WALL DETAIL
3/4" = 1'-0"
WALL DETAIL
3/4" = 1'-0"
WALL DETAIL
1 1/2" = 1'-0"
STRUCTURAL DETAIL
1 1/2" = 1'-0"
STRUCTURAL DETAIL
Revisions: Date:
2' -8
REFER TO PLAN
TO SPANDREL
8"
PCC WALL PANEL
BEARING PAD, TYP
PCC SPANDREL
BACKER ROD &
SEALANT, TYP
PCC WALL PANEL
LATERAL CONN BY PCC MFR
TYP BETWEEN WALL PANEL
& SPANDREL TOP & BOT
PROVIDE HIDDEN HAUNCH
CONN AT COLUMN BEYOND
LATERAL CONNS AT COLUMN
BY PCC MFR
AT ELEVATOR DIVIDER OR
SAFETY BEAM, EMBED PLATE BY
PCC MFR W/ STEEL CONN BY
STEEL FABRICATOR. PROVIDE
BOLTED CONN AT SAFETY BEAM
FOR FUTURE EXPANSION.
2' -8
REFER TO PLAN
TO SPANDREL
PCC SPANDREL
GLAZING
REFER TO ARCH
PROVIDE HIDDEN HAUNCH
CONN AT COLUMN BEYOND
LATERAL CONNS AT COLUMN
BY PCC MFR
8" 8"
2' -8
PCC SPANDREL
GLAZING
REFER TO ARCH
8"
REFER TO PLAN
TO SPANDREL
PROVIDE HIDDEN HAUNCH
CONN AT COLUMN BEYOND
LATERAL CONNS AT COLUMN
BY PCC MFR
REFER TO PLAN
TOS EL
TOOLED JT W/ SEALANT
CONN BY PCC MFR
PCC STAIRS W/
FIELD TOPPING
CONC DAM
BEARING PAD
HAUNCH
8" MIN
8" PCC WALL PANEL
COVE SEALANT
CIP TOPPING
PCC SPANDREL
PCC DT
TOS EL
REFER TO PLAN
6" 10"
10" PCC WALL PANEL
3"
REFER TO PLAN WASH, REFER TO PLAN
WALL CONN TO DT
BY PCC MFR
TOS EL
REFER TO PLAN
LA
P
S P
LI
C
E
2' -6
6" 3"
8" 8"
6" 8"
2' -8
8" CMU WALL
W/ #5 @ 16" OC
GROUT CORES
SOLID AT REINF
HSS SECTION
REFER TO PLAN
REFER TO PLAN
TO STL
EMBED PLATE CONNECTION
COORDINATE DESIGN
LOADS W/ ELEVATOR
SUPPLIER
#5 @ 16" OC W/ DOWEL
BAR SUBSTITUTE
BACKER ROD & SEALANT
PCC BEAM
PCC SLAB
#4 @ 12"
OC X 4'-0"
CIP TOPPING
TOOLED JT
W/ SEALANT
REFER TO DET 12/SF551
TOS EL
REFER TO PLAN
LA
P
S P
LI
C
E
2' -6
6" 3"
8" 8"
6" 8"
2' -8
8" CMU WALL W/
#5 @ 16" OC
GROUT CORES
SOLID AT REINF
#5 @ 16" OC W/ DOWEL
BAR SUBSTITUTE
BACKER ROD & SEALANT
PCC BEAM
PCC SLAB
#4 @ 12"
OC X 4'-0"
CIP TOPPING
TOOLED JT
W/ SEALANT
8"
2' -8
3" 5"
6"
PCC WALL PANEL
BEARING PAD, TYP
COVE SEALANT
PCC SPANDREL
CHORD REINF
REFER TO PLAN
PCC TEE
BACKER ROD &
SEALANT, TYP
PCC WALL PANEL
GALV EMBED &
ANGLE BY PCC MFR
6"
PROVIDE HIDDEN HAUNCH
CON AT COLUMN BEYOND
LATERAL CONNS AT
COLUMN BY PCC MFR
#4 @ 12" EW BOT
LATERAL CONN BY PCC MFR
TYP BETWEEN WALL PANEL
& SPANDREL, TOP & BOT
REFER TO PLAN
TO SPANDREL
8" 4" 3'-0" WASH
BUTTON HAUNCHES
AT TEE STEMS, 8"
WIDE, MIN
CHORD REINF,
REFER TO PLANS
CONN BY PCC
MANUFACTURER
CIP TOPPING
COVE SEALANT
CONC DAM
BEARING PAD
2' -8
3"
W A
S H
3' -6
M
IN
ELEVATION
REFER TO PLAN
PCC TEE
PCC SPANDREL
PROVIDE DAPPED SPANDREL
SUPPORT AT COL OR PROVIDE
HAUNCH BELOW AT COL AND
COORD WITH WALL PANEL
PCC WALL PANEL
BACKER ROD &
SEALANT, TYP
BEARING PAD, TYP
LATERAL CONN BY PCC
MFR TYP BETWEEN
WALL PANEL &
SPANDREL, T & B
8" 4" 3'-0" WASH
CHORD REINF,
REFER TO PLANS
CONN BY PCC
MANUFACTURER
CIP TOPPING
TOOLED JT W/ SEALANT
CONC DAM
ELEVATION
REFER TO PLAN
PCC TEE
3" W
A S
H 2'
-8
SOLID 6" PCC
SLAB W/ 3"
FIELD TOPPING
CONN BY PCC MFR
BUTTON HAUNCHES
AT TEE STEMS, 8"
WIDE, MIN
BEARING PAD
PROVIDE DAPPED SPANDREL
SUPPORT AT COL OR PROVIDE
HAUNCH BELOW AT COL AND
COORD WITH GLAZING BELOW
SUMP PIT
2'-0"
L3 3 X 1/4 (4) SIDES W/1/2" EXPANSION
BOLTS @ 12" OC (MIN 2 PER SIDE)
2' -0
1" STEEL GRATING (GALV)
CIP FOUNDATION, REFER
TO PLAN
CIP FOUNDATION WALL
PROVIDE (1) ADDL TOP BAR
ALL 4 SIDE OF OPENING
TERMINATE MAT REINF W/ STD
HOOK WHERE INTERRUPTED
BY BLOCKOUT, TYP
CMU LINTEL REFER
TO DET 8/SF551
BOTTOM OF
PCC BEAM
PCC SLAB
PCC BEAM
VERTICAL JT W/ BACKER ROD AND SEALANT
CONTINUE MASONRY JT REINF THRU VERT JT
KNOCK-OUT PANEL IN MASONRY WALL
FOR FUTURE ELEVATOR COORD DIMS
W/ ELEVATOR SUPPLIER
NO VERT WALL REINF PROVIDE
CONTINUOUS HORIZ JT REINF THRU
KNOCK-OUT PANEL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
M/E/P Engineers: Structural Engineer:
Apogee Consulting Group, PA
1511 Kildaire Farm Road, Suite 120
Cary, NC 27511
(919) 858-7420
Carl Walker, a Division of WGI
8910 Purdue Road, Suite 400
Indianapolis, IN 46828
(317) 735-3349
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100
Indianapolis, IN 46204
(317) 800-6388
BID DOCUMENT
NOT SPRINKLERED
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
DPG DEB
D R e v it U s e r
F ile s \P
-2
-0
-C
W I-
V d a n .b ro w n L D
P W
Z .r v t
/7
/2
:0 :1
P
M
SF562
ENLARGED PLAN DETAILS -
STRUCTURAL
1/9/2019 42 OF 80
3/4" = 1'-0"
PCC DETAIL
3/4" = 1'-0"
PCC DETAIL
3/4" = 1'-0"
PCC DETAIL
3/4" = 1'-0"
STRUCTURAL DETAIL
3/4" = 1'-0"
STRUCTURAL DETAIL
3/4" = 1'-0"
STRUCTURAL DETAIL
3/4" = 1'-0"
PCC TEE TO PCC SPANDREL DETAIL
3/4" = 1'-0"
PCC TEE TO PCC SPANDREL DETAIL
3/4" = 1'-0"
PCC TEE TO PCC SPANDREL DETAIL
3/4" = 1'-0"
SUMP PIT DETAIL
1/4" = 1'-0"
ELEVATION
3/4" = 1'-0"
REFER TO PLAN
CONC WASH 8" 8"
REFER TO PLAN
TOS EL REFER TO PLAN
TO LANDING
TOOLED JOINT W/ SEALANT
PCC COL (BEYOND)
CONC DAM
PCC STAIRS W/
FIELD TOPPING
PCC SPANDREL
HAUNCH CONN
@ COL BEYOND
PCC DT
REINF REFER
TO PLAN
REFER TO PLAN
CONC WASH 8" 8"
REFER TO PLAN
TOS EL
PCC WALL PANEL
CONC DAMREINF REFER
TO PLAN
BEARING PAD TYP
CONN BY PCC MFR
BACKER ROD &
SEALANT TYP
LATERAL CONN BY PCC MFR
TYP BETWEEN WALL PANEL
& SPANDREL TOP & BOT
PCC DT
TOS EL
REFER TO PLAN
6" 3"
6" 8"
2' -8
HSS SECTION
REFER TO PLAN
REFER TO PLAN
TO STL
EMBED PLATE CONNECTION
COORDINATE DESIGN
LOADS W/ ELEVATOR
SUPPLIER
#5 @ 16" OC W/ DOWEL
BAR SUBSTITUTE
BACKER ROD & SEALANT
PCC BEAM
PCC SLAB
#4 @ 12"
OC X 4'-0"
CIP TOPPING
REFER TO DET 12/SF551
8" 8"
TOW EL
REFER TO PLAN
PCC SPANDREL
BEAM
REFER TO PLAN
TOS EL
6"
BACKER ROD
& SEALANT
PCC WALL PANEL
W/ TOP & BOT
CONN BY PCC MFR
PCC SLAB
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
M/E/P Engineers: Structural Engineer:
Apogee Consulting Group, PA
1511 Kildaire Farm Road, Suite 120
Cary, NC 27511
(919) 858-7420
Carl Walker, a Division of WGI
8910 Purdue Road, Suite 400
Indianapolis, IN 46828
(317) 735-3349
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100
Indianapolis, IN 46204
(317) 800-6388
BID DOCUMENT
NOT SPRINKLERED
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
DPG DEB
D R e v it U s e r
F ile s \P
-2
-0
-C
W I-
V d a n .b ro w n L D
P W
Z .r v t
/7
/2
:0 :1
P
M
SF563
ENLARGED PLAN DETAILS -
STRUCTURAL
1/9/2019 43 OF 80
3/4" = 1'-0"
PCC TEE TO PCC SPANDREL DETAIL
3/4" = 1'-0"
PCC TEE TO PCC SPANDREL DETAIL
3/4" = 1'-0"
A B C
NORTH-SOUTH DIRECTION
NOTES:
1. MAXIMUM VOLUME CHANGE MOVEMENTS, + = SHORTENING, - = LENGTHENING.
2. VOLUME CHANGES INDICATED ARE DUE TO CREEP, SHRINKAGE AND THERMAL EFFECTS, BASED ON PCI HANDBOOK, 7TH ED. MAXIMUM
SEASONAL CLIMATIC CHANGE OF 68°, (DESIGN AID 4.11.11) AND 69% RELATIVE HUMIDITY (DESIGN AID 4.11.12).
3. USE LINEAR INTERPOLATION TO DETERMINE VOLUME CHANGE AT INTERMEDIATE COLUMNS.
4. DISPLACEMENTS INDICATED HAVE BEEN REDUCED BY Kl = 4, Kt = 1.5 IN ACCORDANCE WITH PCI HANDBOOK, CHAPTER 4.
5. XX" ± XX" THE FIRST NUMBER INDICATES THE AMOUNT OF CREEP AND SHRINKAGE MOVEMENT. THE SECOND NUMBER INDICATES THE
AMOUNT OF TEMPERATURE CHANGE MOVEMENT.
6. ABOVE VALUES ARE CALCULATED BASED ON FUTURE EXPANSION
LEVEL 3
LEVEL 2
TO FOUNDATION
3 4 6 85 71
LEVEL 3
LEVEL 2
TO FOUNDATION
.09± 0.23
63'-4". 63'-4".
0.03± 0.08 0.03± 0.07
45'-4". 32'-0". 32'-0". 32'-0". 32'-0". 32'-0". 45'-4".
0.10± 0.27 0.06± 0.16 0.03± 0.09 0.00± 0.01 0.03± 0.06 0.05± 0.14 0.08± 0.21 0.13± 0.32
EAST-WEST DIRECTION
1 8
15'-0" *
18'-3".
P
S F
.7
P S
F
.4
P S
F
ROOF DOUBLE TEE LIVE LOAD Lr (UNO)
40 PSF
BAY WIDTH
ROOF DOUBLE TEE SNOW LOAD - CASE 4
A C
11'-0"*
18'-3".
P
S F
.6
P S
F
.4
P S
F
B
ROOF DOUBLE TEE SNOW LOAD - CASE 2 (GRIDS A-B AND C-D)
ROOF DOUBLE TEE SNOW LOAD - CASE 1
21 PSF
BAY WIDTH
2 7
* NOTE - APPLIES TO SNOW LOAD AT STAIR TOWERS
* NOTE - APPLIES TO SNOW LOAD AT STAIR TOWERS
716'-3"
LEVEL 1
727'-7"
LEVEL 2
713'-0"
TOF
18'-0" 18'-0"
WIND 41k
SEISMIC 36k
738'-11"
LEVEL 3
750'-3"
LEVEL 4
761'-7"
LEVEL 5
772'-11"
LEVEL 6
784'-3"
LEVEL 7
WIND 41k
SEISMIC 39k
WIND 41k
SEISMIC 39k
WIND 41k
SEISMIC 39k
WIND 41k
SEISMIC 39k
WIND 21k
SEISMIC 12k
B
FUTURE EXPANSION
719'-9"
LEVEL 1
730'-11"
LEVEL 2
713'-0"
TOF
WIND 44k
SEISMIC 38k
18'-0" 18'-0"
742'-3"
LEVEL 3
753'-7"
LEVEL 4
764'-11"
LEVEL 5
776'-3"
LEVEL 6
WIND 42k
SEISMIC 38k
B
FUTURE EXPANSION
WIND 42k
SEISMIC 38k
WIND 42k
SEISMIC 38k
WIND 42k
SEISMIC 38k
2 3 4 5 6 7
719'-9"
LEVEL 1
730'-11"
LEVEL 2
WIND 29k
SEISMIC 37k
716'-3"
LEVEL 1
727'-7"
LEVEL 2
738'-11"
LEVEL 3 WIND 24k
SEISMIC 32k
750'-3"
LEVEL 4
761'-7"
LEVEL 5
772'-11"
LEVEL 6
784'-3"
LEVEL 7
742'-3"
LEVEL 3
753'-7"
LEVEL 4
764'-11"
LEVEL 5
776'-3"
LEVEL 6
787'-7"
LEVEL 7
FUTURE EXPANSION
WIND 24k
SEISMIC 32k
WIND 24k
SEISMIC 32k
WIND 24k
SEISMIC 32k
WIND 17k
SEISMIC 14k
4 5
WIND 28k
SEISMIC 36k
716'-3"
LEVEL 1
727'-7"
LEVEL 2
738'-11"
LEVEL 3 WIND 28k
SEISMIC 39k
750'-3"
LEVEL 4 WIND 28k
SEISMIC 39k
761'-7"
LEVEL 5 WIND 28k
SEISMIC 39k
772'-11"
LEVEL 6 WIND 28k
SEISMIC 39k
784'-3"
LEVEL 7 WIND 14k
SEISMIC 13k
FUTURE EXPANSION
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
M/E/P Engineers: Structural Engineer:
Apogee Consulting Group, PA
1511 Kildaire Farm Road, Suite 120
Cary, NC 27511
(919) 858-7420
Carl Walker, a Division of WGI
8910 Purdue Road, Suite 400
Indianapolis, IN 46828
(317) 735-3349
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100
Indianapolis, IN 46204
(317) 800-6388
BID DOCUMENT
NOT SPRINKLERED
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
DPG DEB
D R e v it U s e r
F ile s \P
-2
-0
-C
W I-
V d a n .b ro w n L D
P W
Z .r v t
/7
/2
:0 :1
P
M
SF611
LOADING DIAGRAMS -
STRUCTURAL
1/9/2019 44 OF 80
1/2" = 1'-0"
VOLUME CHANGE DIAGRAMS
1/8" = 1'-0"
ROOF DOUBLE TEE LOADING
1/8" = 1'-0"
LATERAL LOAD DIAGRAM - SHEAR WALL AT B/1
1/8" = 1'-0"
LATERAL LOAD DIAGRAM - SHEAR WALL AT B/8
1/8" = 1'-0"
LATERAL LOAD DIAGRAM - GRID B
1/8" = 1'-0"
LATERAL LOAD DIAGRAM - SHEAR WALL AT C/4-5
C
ALL LETTERING TO BE
PAINTED BLACK
WITH EXCEPTION OF
PROJECT TITLE
WHICH IS TO BE BLUE
PAINT BORDER MEMBER
BLACK ENAMEL
2"x4" [51x102mm]
FRAME AND BRACES IN
SAME PLANE
METAL FACE
WHITE ENAMEL
2"x4" [51x102mm]
FRAME AND
BRACE IN BACK
BORDER MEMBER
PAINTED BLACKBACKGROUND TO
BE PAINTED WHITE
METAL FACE
STRETCH METAL FACE
TIGHT, TURN OVER FRAME
AND SECURE WITH FLAT
HEAD DEFORMED NAILS.
LETTERING TO BE
HELVETICA STYLE 1 1/2"
[38mm] HIGH TO BE
CENTERED HORIZONTAL
NOTE:
ANY SEAM IN METAL TO
BE FLAT SEAM - SEAMS TO BE
HORIZONTAL AND OCCUR
BETWEEN LINES OF LETTERING.
4"x4" [102x102mm]
POSTS PAINTED
WHITE
SECTION ON CENTERLINEELEVATION
A/E TO PROVIDE DIGITAL
LOGO AND ADDRESS
THIS SPACE FOR PROJECT TITLE
LETTERING TO BE HELVETICA STYPE 5"
HIGH CENTERED BETWEEN LETTERING
ABOVE AND BELOW ONE OR TWO LINES
AS REQUIRED
DESIGNED AND SUPERVISED BY:
DEPARTMENT OF VETERANS
AFFAIRS WASHINGTON D.C.
GENERAL CONTRACTOR
L
GC TO PROVIDE DIGITAL
LOGO AND ADDRESS
8'-0"
2"
M
A X
6' -0
M A
X
3' -0
A
V E
R A
G E
4' -0
M
IN
WALL TYPE LEGEND
M8.A2
EPOXY
8" X 8" X 16" CMU
PROVIDE 1" MIN GAP TO
ALLOW FOR SLIP
MOVEMENT. CAULK BOTH
SIDES
8" CMU WALL UP TO UNDER SIDE OF
STAIR / LANDING
DOWEL, RE: STRUCT
FOR WALL
REINFORCEMENT
M8.A1
EPOXY
8" X 8" X 16" CMU
PROVIDE 1" MIN GAP TO
ALLOW FOR SLIP
MOVEMENT.
COMPRESSIBLE FIRE
CAULK BOTH SIDES
8" CMU WALL TO DECK
SMOKE PARTITION
DOWEL, RE: STRUCT FOR WALL
REINFORCEMENT
FILL WITH PERLITE
M8.A3
EPOXY
8" X 8" X 16" CMU
PROVIDE 1" MIN GAP TO
ALLOW FOR SLIP
MOVEMENT.
COMPRESSIBLE FIRE
CAULK BOTH SIDES
8" CMU WALL TO DECK
2 HR RATED PARTITION
UL# U905
DOWEL, RE: STRUCT FOR WALL
REINFORCEMENT
FILL WITH PERLITE
GENERAL CONSTRUCTION NOTES
THE CONTRACT DOCUMENT DRAWINGS HAVE BEEN PREPARED USING REVIT®
SOFTWARE IN A MICROSOFT WINDOWS ENVIRONMENT. A BUILDING INFORMATION
MODEL (BIM) HAS BEEN DEVELOPED FOR DESIGN COMMUNICATION. THE MODEL
DOES NOT CONTAIN COMPLETE INFORMATION FOR USE IN COST ESTIMATING,
SYSTEMS PERFORMANCE, COORDINATION, SCHEDULING, OR FACILITIES
MANAGEMENT.
THE CONTRACT DOCUMENT DRAWINGS HAVE BEEN PREPARED USING THE
CONSTRUCTION SPECIFICATIONS INSTITUTE'S UNIFORM DRAWING SYSTEM AND THE
NATIONAL CAD STANDARD AS GUIDES.
DISCREPANCIES IN THE CONTRACT DOCUMENTS SHALL BE IMMEDIATELY BROUGHT
TO THE ATTENTION OF THE ARCHITECT AND OWNER’S REPRESENTATIVE/COR.
CONTRACTOR SHALL PROVIDE THE HIGHER GRADE OF QUALITY AND/OR GREATER
QUANTITY OF WORK WHEN BIDDING IF A CLARIFICATION CAN NOT BE OBTAINED BY
THE BID DUE DATE.
CONTRACTOR IS RESPONSIBLE FOR COORDINATING SCOPE OF WORK WITH OWNER’S
REPRESENTATIVE/COR AND VARIOUS FACILITY PERSONNEL INVOLVED WITH UTILITY
SHUT DOWN, INFECTION CONTROLS, OCCUPANT/EMPLOYEE SAFETY, ACCESS
CONTROL, ETC.
ANY INDICATION OF PROJECT LIMITS OR BOUNDARY OF DEMARCATION ARE SHOWN
FOR THE CONVENIENCE OF THE CONTRACTOR, THE FULL SCOPE OF THE PROJECT
LIMIT OF BOUNDARY REQUIRES COORDINATION WITH THE DESIGN SCOPE OF WORK
AND ACCESS TO EXISTING UTILITIES FOR TIE IN.
DRAWINGS ARE PREPARED FROM FIELD VERIFICATION, EXISTING FACILITY DRAWING
BASE FILES, AND USING DIMENSIONS, CONFIGURATIONS AND DETAILS OF SPECIFIC
MANUFACTURERS AS A BASIS OF DESIGN. CONTRACTOR IS RESPONSIBLE FOR
VERIFICATION OF ACTUAL DIMENSIONS, THE COORDINATION OF THE DETAILS WITH THE
PRODUCTS WHICH ARE PROVIDED PER THE SCOPE OF THE SPECIFICATIONS AND THE
SURROUNDING CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS, ROUGH-IN
DIMENSIONS, CONNECTIONS, AND OVERALL INSTALLATION REQUIREMENTS.
CONTRACTOR IS RESPONSIBLE FOR THE COMPLETION OF THE ENTIRE SCOPE OF
WORK OUTLINED IN THE CONTRACT DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR
THE COORDINATION OF ALL SUB-CONTRACTORS AND THE SCOPE OF WORK THEY
PROVIDE. SUB-CONTRACTORS ARE RESPONSIBLE FOR THEIR FULL SCOPE OF WORK
WITHIN THE CONTRACT DOCUMENTS, TRADES ARE NOT SEGMENTED TO ONLY CERTAIN
SHEETS AND SPECIFICATIONS, CROSS COORDINATION IS REQUIRED.
CONTRACTOR AND SUB-CONTRACTORS ARE BOTH RESPONSIBLE FOR
UNDERSTANDING INFORMATION OUTLINED IN THE SPECIFICATIONS, KEY NOTES,
GENERAL NOTES, LEGEND, CODES, ETC., PROVIDED IN THE CONTRACT DOCUMENTS.
CONTRACTOR AND SUB-CONTRACTORS ARE BOTH RESPONSIBLE FOR PROVIDING AND
MAINTAINING SMOKE/FIRE RATINGS OF NEW CONSTRUCTION AND EXISTING
CONSTRUCTION AS INDICATED ON DRAWINGS. THIS INCLUDES PATCHING
PENETRATIONS IN SHAFTS, WALLS, SLABS AND ROOF. ONLY U.L. AND/OR I.C.B.O.
APPROVED METHODS, MATERIALS AND INSTALLATION ARE ACCEPTABLE.
MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS SHOW INFORMATION IN A
DIAGRAMMATIC FASHION WITHOUT DIMENSIONING. THE GENERAL CONTRACTOR IS TO
COORDINATE THE LOCATIONS OF ALL MECHANICAL, PLUMBING AND ELECTRICAL
EQUIPMENT WITH RESPECT TO THE ARCHITECTURAL AND STRUCTURAL DETAILING OF
SHAFTS, CHASES, CEILING CONSTRUCTION, ETC.
CONTRACTOR IS RESPONSIBLE FOR VERIFYING DIMENSIONS IDENTIFIED AND NOT
IDENTIFIED IN THE CONTRACT DOCUMENTS WITH THE EXISTING AND NEW
CONSTRUCTION ELEMENTS. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION
BETWEEN THE CONTRACT DOCUMENTS, INSTALLED AND UNINSTALLED
CONSTRUCTION BEFORE THE ORDERING OF MATERIALS AND EQUIPMENT. NOTIFY
ARCHITECT AND OWNER’S REPRESENTATIVE/COR OF ANY DISCREPANCIES OR MISSING
DIMENSIONS.
DO NOT SCALE THE DRAWINGS. DRAWING SCALES AS INDICATED ARE FOR GENERAL
ORIENTATION AND CONTEXT ONLY.
THE TERM "ALIGN" MEANS TO INSTALL DIFFERENT/SIMILAR COMPONENTS OF
CONSTRUCTION TO PROVIDE A FLUSH FINISH SURFACE.
ALL DIMENSIONS INDICATED ARE TO FACE OF EXISTING MEMBERS, FACE OF NEW
STRUCTURAL MEMBERS, FACE OF NEW MASONRY, FACE OF NEW STUDS OR COLUMN
GRID LINES UNLESS NOTED OTHERWISE.
FLOOR ELEVATION 0’-0” IS EQUAL TO THE FINISH FLOOR SLAB OF THE EXISTING SLAB
FLOOR CONSTRUCTION.
ROUGH OPENINGS SHALL ALLOW FOR SHIM SPACE.
CONTRACTOR TO PROVIDE WORK WHERE DETAILS AND NOTES ARE IDENTIFIED AS
“TYPICAL” OR “SIMILAR” EACH INSTANCE THAT IS THE SAME IN NATURE TO THE DETAIL,
AREA, OR ITEM REFERENCED.
PROVIDED WORK SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR.
CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF DELIVERY, MOUNTING,
INSTALLATION AND ROUGH-IN.
INSTALLED WORK IS THE CONTRACTOR INSTALLING OWNER FURNISHED MATERIALS
AND EQUIPMENT. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF MATERIAL
DELIVERY, MOUNTING, INSTALLATION AND ROUGH IN.
FURNISHED WORK IS THE CONTRACTOR FURNISHING THE MATERIALS AND EQUIPMENT
TO THE OWNER. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF DELIVERY AND
ROUGH-IN.
ALL PROVIDED WORK SHALL BE WITH NEW MATERIALS UNLESS SPECIFICALLY CALLED
OUT AS SALVAGED OR RELOCATED WITHIN THE CONTRACT DOCUMENTS.
ALL PERSONS DIRECTLY OR INDIRECTLY ASSOCIATED WITH THE PROJECT SHALL BE
FAMILIAR WITH THE RULES AND REGULATIONS OF THE OCCUPATIONAL SAFETY AND
HEALTH ACT, AND IMPLEMENT THOSE RULES AS THEY APPLY TO THIS PROJECT.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL
UTILITY LINES. LOCATIONS SHOWN ARE APPROXIMATE. REPAIR ALL DAMAGE TO UTILITY
LINES CAUSED BY CONSTRUCTION OPERATIONS AT NO COST TO THE OWNER.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TEMPORARY BRACING AND SHORING
REQUIRED DURING CONSTRUCTION.
CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ADJACENT CONSTRUCTION,
FINISHES, EQUIPMENT, AND TRAVEL ROUTE TO AND FROM THE CONSTRUCTION SITE.
ANY DAMAGE OR UNACCEPTABLE WEAR BY THE CONSTRUCTION TEAM SHALL BE
REPAIRED/REPLACED BY THE CONTRACTOR AT NO COST TO THE OWNER.
IN THE CASE OF CONFLICTS OR DISCREPANCIES WITHIN OR AMONG THE CONTRACT
DRAWINGS, THE BETTER QUALITY, MORE STRINGENT REQUIREMENTS OR GREATER
QUALITY OF WORK, AS DETERMINED BY THE GOVERNMENT, SHALL BE PROVIDED.
CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND COORDINATING HARDWARE,
ACCESS CONTROL AND AUTOMATIC OPERATORS ARE PROVIDED WITH COMPLETE
AND COMPATIBLE SYSTEMS. REFER TO DOOR HARDWARE SCHEDULE, HARDWARE
SPECIFICATIONS, AUTOMATIC OPERATOR SPECIFICATIONS, ACCESS CONTROL
SPECIFICATIONS AND ELECTRICAL DRAWINGS.
A/C AIR CONDITIONING
ACOUS ACOUSTICAL
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
A&E ARCHITECT AND ENGINEERS
AFF ABOVE FINISH FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITIES HAVING JURISDICTION
AHU AIR HANDLING UNIT
ALT ALTERNATIVE
ALT TRANS ALTERNATIVE TRANSPORTATION
ALUM ALUMINUM
ANOD ANODIZED
APPROX APPROXIMATE
ARCH ARCHITECTURAL
AVG AVERAGE
BB BULLETIN BOARD
BD BOARD
BG BUMPER GUARD
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BO BOTTOM OF
BRG BEARING
CB CATCH BASIN
CBB CEMENTITIOUS BACKER BOARD
CER CERAMIC
CF CUBIC FEET
CFCI CONTRACTOR FURNISH CONTRACTOR INSTALL
CFM CUBIC FEET PER MINUTE
CG CORNER GUARD, CEILING GRILLE
C & G CURB & GUTTER
CI CAST IRON
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNITS
CO CLEANOUT(S)
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
COORD COORDINATE
CP CONCRETE PIPE
CPT CARPET
CRS COLD ROLLED STEEL
CS CAST STONE
CSB CONCRETE SPLASH BLOCK
CSI CONSTRUCTION SPECIFICATIONS INSTITUTE
CT CERAMIC TILE
CTR CENTER
CU FT CUBIC FEET
CUH CABINET UNIT HEATER
CY CUBIC YARD
D DRYER
DEG DEGREE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DISP DISPENSER
DIV DIVISION
DN DOWN
DR DOOR
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
E EAST
(E) EXISTING
EA EACH
EF EXHAUST FAN
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EQ EQUAL
EQUIP EQUIPMENT
EST ESTIMATED
ETS EXPOSED TO STRUCTURE
ETR EXISTING TO REMAIN
ARCHITECTURAL ABBREVIATIONS
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FCU FAN COIL UNIT
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FF & E FURNITURE FIXTURES & EQUIPMENT
FIN FINISH
FIXT FIXTURE
FL FLOW LINE
FLR FLOOR
FLUOR FLUORESCENT
FO FINISH OPENING
FOS FACE OF STUD
FR FIRE RATED
FSP FIRE STANDPIPE
FT FOOT / FEET
FTG FOOTING
FURR FURRING
FV FIELD VERIFY
FVC FIRE VALVE CABINET
FWC FABRIC WALLCOVERING
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GD GARBAGE DISPOSAL
GF CMU GROUND FACE CMU
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GI GALVANIZED IRON
GL GLASS
GL BLK GLASS BLACK
GLU LAM GLUE LAMINATED WOOD
GND GROUND
GT GROUT
GYP BD GYPSUM BOARD
HAZ MAT HAZARDOUS MATERIALS
HB HOSE BIB
HC HOLLOW CORE
HCP HANDICAPPED
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HGT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR, HANDRAIL
HT HEIGHT
HVAC HEATING, VENTILATING & AIR CONDITIONING
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER
IG INSULATING GLASS
IN INCH
INCAN INCANDESCENT
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
INV INVERT
ITG INSULATED TEMPERED GLASS
JAN JANITOR
J-BOX JUNCTION BOX
JT JOINT
L LONG
LAV LAVATORY
LB(S) # POUND(S)
LF LINEAL FEET
LLV LONG LEG VERTICAL
LT LIGHT
LVR LOUVER
M & BH MOP AND BROOM HOLDER
MAINT MAINTENANCE
MATL MATERIAL
MAX MAXIMUM
MB MARKER BOARD
MECH MECHANICAL
MEPF MECHANICAL, ELECTRICAL, PLUMBING,
FIRE PROTECTION (CONDUIT)
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MO MASONRY OPENING
MSB MOP SERVICE BASIN
MTD MOUNTED
MTL METAL
N NORTH
NA NOT APPLICABLE
NECY NECESSARY
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER,
OVERFLOW DRAIN
OFCI OWNER FURNISHED
CONTRACTOR INSTALLED
OFOI OWNER FURNISHED
OWNER INSTALLED
OH OPPOSITE HAND
OPN OPENING
OPP OPPOSITE
ORD OVERFLOW ROOF DRAIN
P PLASTIC
PARTN PARTITION
PBD PARTICLE BOARD
PCC PRECAST CONCRETE
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLYWD PLYWOOD
PR PAIR
PRCST PRECAST
PREFAB PREFABRICATED
PROP PROPERTY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT
PT CONC POST-TENSIONED CONCRETE
PTD PAPER TOWEL DISPENSER
PTL PORCELAIN TILE
PVC POLYVINYL CHLORIDE
QA QUALITY ASSURANCE
QT QUARRY TILE
R R-VALUE (INSULATION),
RADIUS, RISER
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE: REFERENCE
REBAR REINFORCING BAR
REC RECESSED
RECPT RECEPTACLE
REF REFRIGERATOR
REG REGISTER
REINF REINFORCE
REQD REQUIRED
RESIL RESILIENT
REV REVISION
RH ROOF HATCH
RM ROOM
RO ROUGH OPENING
RT RUBBER STAIR TREAD
S SOUTH
SAF SEAMLESS ACRYLIC FLOORING
SAP SUSPENDED ACOUSTICAL PANELS
SAT SUSPENDED ACOUSTICAL TILE
SB SPLASHBLOCK
SC SEALED CONCRETE, SOLID CORE
SCHED SCHEDULE
SCP SCUPPER
SD SOAP DISPENSER
SEAL SEALER
SECT SECTION
SECT SECTION
SF SQUARE FOOT
SF CMU SPLIT-FACE CMU
SHR SHOWER
SHT SHEET
SHTG SHEATHING
SIM SIMILAR
SL SLOPE
SLV SHORT LEG VERTICAL
SND SANITARY NAPKIN DISPOSER
SNV SANITARY NAPKIN VENDOR
SPECS SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STOR STORAGE
STRUC STRUCTURAL
SUSP SUSPENDED
SV SHEET VINYL
SYM SYMMETRICAL
SYS SYSTEM
T TREAD
TA TOILET ACCESSORIES
TB TACKBOARD
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TBD TO BE DETERMINED
TD TUBULAR DAYLIGHTING DEVICE
TEL TELEPHONE
TEMP TEMPERATURE
TG TEMPERED GLASS,
TONGUE & GROOVE,
TRANSFER GRILLE
THRU THROUGH
TO TOP OF
TOC TOP OF CONCRETE
TOM TOP OF MASONRY
TOS TOP OF STEEL
TOW TOP OF WALL
TTD TOILET TISSUE DISPENSER
TV TELEVISION
TYP TYPICAL
UGND UNDERGROUND
UL UNDERWRITERS LABORATORY
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
URN URINAL
VB VINYL BASE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VIF VERIFY IN FIELD
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
W WEST
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WDP WOOD PANELING
WDW WINDOW
WF WIDE FLANGE
WGL WIRED GLASS
WH WATER HEATER
WR WASTE RECEPTACLE,
WATER RESISTANT
WS WATER STOP
WSCT WAINSCOTT
WT WEIGHT
WWF WELDED WIRE FABRIC
ARCHITECTURAL SYMBOLS
X
X
XXXX
SHEET LOCATION
VIEW NUMBER
X X
X
SHEET LOCATION
VIEW NUMBER
XXXX
BUILDING SECTION REFERENCE
SECTION REFERENCE
DRAWING NUMBER
SHEET LOCATION
DRAWING NUMBER
SHEET LOCATION
DRAWING NUMBER
SHEET LOCATION
DETAIL REFERENCE
BUILDING
OBJECT
REFERENCED
OBJECT
REFERENCED
X
XXXX
X
XXXX
ELEVATION REFERENCES
X
XXXX
X
XXXX
SCALE: ??
VIEW TITLE
HANDICAP SYMBOL
N
TRUE NORTH ARROW
ROOM
NEW WALL
WALL TO BE REMOVED
NEW WALL TAG
S3.A2
INDICATES STRUCTURAL MATERIAL
INDICATES NOMINAL SIZE
INDICATES CONSTRUCTION
INDICATES TOP OF WALL CONDITION
REFER TO WALL LEGEND
FOR MORE INFORMATION
NEW DOOR101
DOOR TAG
EXISTING DOOR
101 ROOM TAG
1 PLAN NOTE
ALTERNATE/BID
DEDUCT ITEM
PT-1 FINISH INDICATION
A STOREFRONT/WINDOW
T GLAZING
ITEMS TO BE DEMOLISHED
DEMOLISHED DOOR
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
EXISTING WALL TO REMAIN
A 9'-0"
CEILING TAG CEILING TYPE
FINISHED CEILING HEIGHT
REFER TO CEILING LEGEND
FOR MORE INFORMATION
EXTENT OF REVISION
REVISION SET
101 EQUIPMENT/FURNITURE TAG
TEMPORARY IC BARRIER WALL
CONSTRUCTION (DUST WALL)
DRAWINGS AND DIMENSIONS
1. THE CONTRACT DOCUMENT DRAWINGS HAVE BEEN PREPARED USING REVIT®
SOFTWARE IN A MICROSOFT WINDOWS ENVIRONMENT. A BUILDING
INFORMATION MODEL (BIM) WAS DEVELOPED SOLELY TO COMMUNICATE THE
DESIGN TO THE OWNER AND IS NOT SUITABLE FOR ANY OTHER PURPOSE.
FOR EXAMPLE THE REVIT MODEL IS NOT SUITABLE FOR COST ESTIMATING,
SYSTEMS PERFORMANCE, COORDINATION, SCHEDULING, OR FACILITIES
MANAGEMENT.
2. THESE DOCUMENTS WERE PRODUCED USING THE CONSTRUCTION
SPECIFICATIONS INSTITUTE'S UNIFORM DRAWING SYSTEM AND THE NATIONAL
CAD STANDARD AS GUIDES.
3. ANY INDICATION OF PROJECT LIMITS OR LINES OF DEMARCATION ARE SHOWN
FOR THE CONVENIENCE OF THE CONTRACTOR, AND ARE NOT TO BE TAKEN
LITERALLY. ACTUAL CONTRACT LIMITS ARE TO BE DETERMINED BY THE
CONTRACTOR AND APPROVED BY THE OWNER BEFORE ACTUAL
CONSTRUCTION WORK BEGINS.
4. DRAWINGS ARE PREPARED USING DIMENSIONS AND PRODUCT
CONFIGURATIONS OR DETAILS OF SPECIFIC MANUFACTURERS. DIMENSIONS
AND DETAILS FOR SPECIFIC PRODUCTS MAY CHANGE BEFORE THEY ARE
ACTUALLY INCORPORATED INTO THE WORK, AND PRODUCTS BY OTHER
MANUFACTURERS ARE ALSO ACCEPTABLE. THEREFORE, ACTUAL
INSTALLATION DETAILS AND DIMENSIONS MAY DIFFER FROM THOSE SHOWN.
CONTRACTOR SHALL VERIFY INSTALLATION REQUIREMENTS FOR ALL
PRODUCTS TO BE INCORPORATED IN THE WORK (INCLUDING THICKNESSES
FOR RECESSED OR SEMI-RECESSED PRODUCTS), AND IS RESPONSIBLE FOR
ACCOMMODATING AND COORDINATING CHANGES TO OTHER MATERIALS OR
PRODUCTS THAT ARE NECESSARY BECAUSE OF THESE DIFFERENCES.
5. THE DRAWINGS AND SPECIFICATIONS ARE SEPARATED INTO DISCIPLINES FOR
CONVENIENCE. THE SEPARATIONS USED ARE USED ONLY FOR THE PURPOSES
OF CONVENIENCE AND REFERENCE AND IN NO WAY DO THEY DEFINE OR LIMIT
THE SCOPE OR INTENT OF ANY PART OF THE DRAWINGS, OR OF THE
DRAWINGS AND SPECIFICATIONS AS A WHOLE. THE FACT THAT THE DRAWINGS
ARE SEPARATED IN NO WAY SUGGESTS THAT THE WORK IS NOT TO BE
CONSTRUCTED AS A COMPLETE, INTEGRATED AND UNIFIED WHOLE.
6. THE DRAWINGS AND SPECIFICATIONS, INCLUDING DRAWINGS PREPARED BY
SPECIFIC ENGINEERING DISCIPLINES (SUCH AS CIVIL, STRUCTURAL,
MECHANICAL, ELECTRICAL, ETC.) ARE COMPLEMENTARY; ITEMS SHOWN IN ANY
ONE LOCATION IN THE DRAWINGS SHALL BE CONSIDERED TO BE
REQUIREMENTS OF THE CONTRACT FOR CONSTRUCTION. IN THE EVENT OF AN
INCONSISTENCY BETWEEN THE DRAWINGS AND SPECIFICATIONS, OR WITHIN
EITHER DOCUMENT, THE CONTRACTOR SHALL SEEK CLARIFICATION OR
INTERPRETATION FROM THE ARCHITECT PRIOR TO BIDDING. WHERE
INCONSISTENCIES ARE NOT CLARIFIED PRIOR TO BIDDING, AND WHERE THE
ACTUAL SOLUTION OR INTENT CANNOT BE REASONABLY INFERRED, THE
CONTRACTOR SHALL PROVIDE THE BETTER QUALITY OR GREATER QUANTITY
OF WORK.
7. USE OF THE WORD "VERIFY" POINTS OUT A SITUATION WHICH MUST BE
CONFIRMED PRIOR TO PROCEEDING WITH THE WORK, FABRICATION OF
EQUIPMENT, OR ORDERING MATERIAL. NOTIFY THE ARCHITECT OF ANY
DISCREPANCY DISCOVERED.
8. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING THE
ARCHITECT IMMEDIATELY SHOULD ANY DISCREPANCIES BE FOUND IN THE
DRAWINGS AND SPECIFICATIONS.
9. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL FIELD
CONDITIONS AND DIMENSIONS AS THEY RELATE TO THIS PROJECT. SHOULD
DISCREPANCIES EXIST BETWEEN THE WORK INDICATED AND ACTUAL FIELD
CONDITIONS NOTIFY THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK.
10. DO NOT SCALE THE DRAWINGS. DRAWING SCALES AS INDICATED ARE FOR
REFERENCE ONLY AND ARE NOT INTENDED TO ACCURATELY DEPICT ACTUAL
OR DESIGNATED CONDITIONS. WRITTEN DIMENSIONS SHALL GOVERN.
11. ALL DIMENSIONS INDICATED ARE TO FACES OF STRUCTURAL MATERIALS OR
COLUMN GRID LINES UNLESS NOTED OTHERWISE. ROUGH OPENINGS SHALL
ALLOW FOR SHIM SPACE.
12. THE TERM "ALIGN" REFERS TO LOCATING DIFFERENT COMPONENTS OF
CONSTRUCTION TO PROVIDE A FLUSH FINISH SURFACE.
13. SHOULD DIMENSIONS BE MISSING OR CONFLICTING, NOTIFY ARCHITECT PRIOR
TO PROCEEDING WITH RELATED WORK.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
M/E/P Engineers: Structural Engineer:
C U s e rs
\t s a n d e rs
\D o c u m e n ts
\1 .1
V A
N o rt h C h ic a g o ts a n d e rs g u id o n d e s ig n .c o m
.r v t
/7
/2
:3
:4
A
M
AS001
ARCHITECTURE SYMBOLS AND
ABBREVIATIONSGuidon Design, Inc.
905 North Capitol Avenue, Suite 100
Indianapolis, IN 46204
(317) 800-6388
Apogee Consulting Group, PA
1511 Kildaire Farm Road, Suite 120
Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 TS KN
BID DOCUMENT
NOT SPRINKLERED
Carl Walker, a Division ofWGI
8910 Purdue Road, Suite 400
Indianapolis, IN 46828
(317) 735-3349
SCALE: 1" = 1'-0"AS001
2 CONSTRUCTION SIGN
UP
L F
OF
FD
N
DR
AI
N
.5
AS201
AS201
ELECTRICAL
SECURITY
OIT
STORAGE
AS202
AS202
AS401
A A
B B
C C
250' - 8"
45' - 4" 32' - 0" 32' - 0" 32' - 0" 32' - 0" 32' - 0" 45' - 4"
8'
STAIR #1
102ELEV 1
LOBBY
101FUTURE ELEV
STAIR #2
0B
AS402
FE
FE
FE
X
A.A
A.1
1.2 1.4 1.7
AS311
AS311
AS311
AS311
AS311
AS311
AS311
AS312
12' - 2"
250' - 8"
8'
B.7
7.8
UP TO LEVEL 2
0'
6'
TRENCH DRAIN
FCO
FCO
GD
CO
CO
GD
FCO
GD
FCO
GD
GD
M8.A1
FE
110A
FLOOR PLAN GENERAL NOTES
SEE STRIPING/SIGNAGE PLANS FOR DETAILS AND DIMENSIONS OF
PAINTED TRAFFIC MARKINGS.
CONTRACTOR TO VERIFY ALL FIELD CONDITIONS AND NOTIFY THE
OWNER AND ARCHITECT OF ANY DISCREPANCIES PRIOR TO THE
BEGINNING OF WORK.
DIMENSIONS INDICATED ARE TO FACES OF CMU/STUDS/STRUCTURE
MATERIALS AND GRID LINES (TYPICAL), UNLESS NOTED OTHERWISE.
PROVIDE SEALANT AT ALL CONCRETE SLAB TO WALL INTERSECTIONS.
REFERENCE STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL
FOR COORDINATION ITEMS. COORDINATE AS REQUIRED INCLUDING
NECESSARY FRAMING, BLOCKING, ETC.
ALL HANDRAILS SHALL BE FABRICATED AND INSTALLED IN
ACCORDANCE WITH ALL REQUIREMENTS OF AMERICANS WITH
DISABILITIES ACT GUIDELINES AND ALL CODES AND REGULATIONS
HAVING JURISDICTION, THE MOST STRINGENT SHALL PREVAIL.
PROVIDE MINIMUM CLEARANCES AT ALL DOORS PER ADA
REQUIREMENTS.
A.
B.
C.
D.
E.
F.
G.
FLOOR PLAN LEGEND AND NOTES #
FALL DETERRENT, REFER TO SHEET AS312 FOR DETAILS. PROVIDE
ABOVE SPANDREL ON ALL EXTERIOR WALLS ABOVE GROUND TIER.
ALSO PROVIDE WHERE GRADE IS 20'-0" BELOW TOP OF SPANDREL AS
INDICATED.
LIGHT POLES MOUNTED ABOVE STRUCTURAL ELEMENTS, REFER
TO ELECTRICAL DRAWINGS. (TBD)
PROVIDE OSHA COMPLIANT ELEVATOR PIT LADDER.
SNOW REMOVAL GATE OPENING, REFER TO STRUCTURAL FOR
ADDITIONAL INFORMATION.
1.
2.
3.
4.
FCO
FE
SMOKE PARTITION
2 HR. - FIRE SEPARATION
FLOOR CLEAN OUT, REFER TO PLUMBING.
FIRE EXTINGUISER, REFER TO SPECIFICATIONS.
GD GARAGE DRAIN, REFER TO PLUMBING.
ISOMETRIC KEYPLAN - LEVEL 1
LEVEL 2
+11'-4"
LEVEL 1
0'-0"
LEVEL 3
+22'-8"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
M/E/P Engineers: Structural Engineer:
C U s e rs
\t s a n d e rs
\D o c u m e n ts
\1 .1
V A
N o rt h C h ic a g o ts a n d e rs g u id o n d e s ig n .c o m
.r v t
/7
/2
:3
:4
A
M
AS101
LEVEL 1 FLOOR PLAN
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100
Indianapolis, IN 46204
(317) 800-6388
Apogee Consulting Group, PA
1511 Kildaire Farm Road, Suite 120
Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 TS KN
BID DOCUMENT
NOT SPRINKLERED
Carl Walker, a Division ofWGI
8910 Purdue Road, Suite 400
Indianapolis, IN 46828
(317) 735-3349
SCALE: 3/32" = 1'-0"AS101
1 LEVEL 1 FLOOR PLAN
N
DN
AS201
AS201
AS202
AS202
AS401
AS402
A A
B B
C C
LOBBY
FUTURE ELEV
ELEV 1
STAIR #2
FE
FE
FE
FE
A.A
A.1
1.2 1.4 1.7
AS311
AS311
AS311
AS311
AS311
AS311
AS312
B.7
7.8
UP TO LEVEL 3
8'
0'
45' - 4" 32' - 0" 32' - 0" 32' - 0" 32' - 0" 32' - 0" 35' - 0" 10' - 4"
250' - 8"
DOWN TO LEVEL 1
10' - 8" 9' - 8" 10' - 8" 14' - 4" 32' - 0" 32' - 0" 32' - 0" 32' - 0" 32' - 0" 45' - 4"
250' - 8"
8'
0'
GD GD GD
GD
GD
STAIR #1
LEVEL 1 BELOW
FLOOR PLAN GENERAL NOTES
SEE STRIPING/SIGNAGE PLANS FOR DETAILS AND DIMENSIONS OF
PAINTED TRAFFIC MARKINGS.
CONTRACTOR TO VERIFY ALL FIELD CONDITIONS AND NOTIFY THE
OWNER AND ARCHITECT OF ANY DISCREPANCIES PRIOR TO THE
BEGINNING OF WORK.
DIMENSIONS INDICATED ARE TO FACES OF CMU/STUDS/STRUCTURE
MATERIALS AND GRID LINES (TYPICAL), UNLESS NOTED OTHERWISE.
PROVIDE SEALANT AT ALL CONCRETE SLAB TO WALL INTERSECTIONS.
REFERENCE STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL
FOR COORDINATION ITEMS. COORDINATE AS REQUIRED INCLUDING
NECESSARY FRAMING, BLOCKING, ETC.
ALL HANDRAILS SHALL BE FABRICATED AND INSTALLED IN
ACCORDANCE WITH ALL REQUIREMENTS OF AMERICANS WITH
DISABILITIES ACT GUIDELINES AND ALL CODES AND REGULATIONS
HAVING JURISDICTION, THE MOST STRINGENT SHALL PREVAIL.
PROVIDE MINIMUM CLEARANCES AT ALL DOORS PER ADA
REQUIREMENTS.
A.
B.
C.
D.
E.
F.
G.
FLOOR PLAN LEGEND AND NOTES #
FALL DETERRENT, REFER TO SHEET AS312 FOR DETAILS. PROVIDE
ABOVE SPANDREL ON ALL EXTERIOR WALLS ABOVE GROUND TIER.
ALSO PROVIDE WHERE GRADE IS 20'-0" BELOW TOP OF SPANDREL AS
INDICATED.
LIGHT POLES MOUNTED ABOVE STRUCTURAL ELEMENTS, REFER
TO ELECTRICAL DRAWINGS. (TBD)
PROVIDE OSHA COMPLIANT ELEVATOR PIT LADDER.
SNOW REMOVAL GATE OPENING, REFER TO STRUCTURAL FOR
ADDITIONAL INFORMATION.
1.
2.
3.
4.
FCO
FE
SMOKE PARTITION
2 HR. - FIRE SEPARATION
FLOOR CLEAN OUT, REFER TO PLUMBING.
FIRE EXTINGUISER, REFER TO SPECIFICATIONS.
GD GARAGE DRAIN, REFER TO PLUMBING.
ISOMETRIC KEYPLAN - LEVEL 2
LEVEL 2
+11'-4"
LEVEL 1
0'-0"
LEVEL 3
+22'-8"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
M/E/P Engineers: Structural Engineer:
C U s e rs
\t s a n d e rs
\D o c u m e n ts
\1 .1
V A
N o rt h C h ic a g o ts a n d e rs g u id o n d e s ig n .c o m
.r v t
/7
/2
:3
:4
A
M
AS102
LEVEL 2 FLOOR PLAN
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100
Indianapolis, IN 46204
(317) 800-6388
Apogee Consulting Group, PA
1511 Kildaire Farm Road, Suite 120
Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 TS KN
BID DOCUMENT
NOT SPRINKLERED
Carl Walker, a Division ofWGI
8910 Purdue Road, Suite 400
Indianapolis, IN 46828
(317) 735-3349
SCALE: 3/32" = 1'-0"AS102
1 LEVEL 2 FLOOR PLAN
FLOOR PLAN GENERAL NOTES
SEE STRIPING/SIGNAGE PLANS FOR DETAILS AND DIMENSIONS OF
PAINTED TRAFFIC MARKINGS.
CONTRACTOR TO VERIFY ALL FIELD CONDITIONS AND NOTIFY THE
OWNER AND ARCHITECT OF ANY DISCREPANCIES PRIOR TO THE
BEGINNING OF WORK.
DIMENSIONS INDICATED ARE TO FACES OF CMU/STUDS/STRUCTURE
MATERIALS AND GRID LINES (TYPICAL), UNLESS NOTED OTHERWISE.
PROVIDE SEALANT AT ALL CONCRETE SLAB TO WALL INTERSECTIONS.
REFERENCE STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL
FOR COORDINATION ITEMS. COORDINATE AS REQUIRED INCLUDING
NECESSARY FRAMING, BLOCKING, ETC.
ALL HANDRAILS SHALL BE FABRICATED AND INSTALLED IN
ACCORDANCE WITH ALL REQUIREMENTS OF AMERICANS WITH
DISABILITIES ACT GUIDELINES AND ALL CODES AND REGULATIONS
HAVING JURISDICTION, THE MOST STRINGENT SHALL PREVAIL.
PROVIDE MINIMUM CLEARANCES AT ALL DOORS PER ADA
REQUIREMENTS.
A.
B.
C.
D.
E.
F.
G.
FLOOR PLAN LEGEND AND NOTES #
FALL DETERRENT, REFER TO SHEET AS312 FOR DETAILS. PROVIDE
ABOVE SPANDREL ON ALL EXTERIOR WALLS ABOVE GROUND TIER.
ALSO PROVIDE WHERE GRADE IS 20'-0" BELOW TOP OF SPANDREL AS
INDICATED.
LIGHT POLES MOUNTED ABOVE STRUCTURAL ELEMENTS, REFER
TO ELECTRICAL DRAWINGS. (TBD)
PROVIDE OSHA COMPLIANT ELEVATOR PIT LADDER.
SNOW REMOVAL GATE OPENING, REFER TO STRUCTURAL FOR
ADDITIONAL INFORMATION.
1.
2.
3.
4.
FCO
FE
SMOKE PARTITION
2 HR. - FIRE SEPARATION
FLOOR CLEAN OUT, REFER TO PLUMBING.
FIRE EXTINGUISER, REFER TO SPECIFICATIONS.
GD GARAGE DRAIN, REFER TO PLUMBING.
AS201
AS201
AS202
AS202
A A
B
C
FE
A.A
A.1
1.2 1.4 1.7
AS311
AS311
B.7
7.8
DOWN TO LEVEL 2
45' - 4" 32' - 0" 32' - 0" 32' - 0" 32' - 0" 32' - 0" 35' - 0" 10' - 4"
250' - 8"
8'
0'
10' - 8" 9' - 8" 10' - 8" 14' - 4" 32' - 0" 32' - 0" 32' - 0" 32' - 0" 32' - 0" 45' - 4"
250' - 8"
6'
ELEV 1
LOBBY
STAIR #1
AS401
Sim
FUTURE ELEV
LEVEL 2 BELOW
ISOMETRIC KEYPLAN - LEVEL 3
LEVEL 2
+11'-4"
LEVEL 1
0'-0"
LEVEL 3
+22'-8"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
M/E/P Engineers: Structural Engineer:
C U s e rs
\t s a n d e rs
\D o c u m e n ts
\1 .1
V A
N o rt h C h ic a g o ts a n d e rs g u id o n d e s ig n .c o m
.r v t
/7
/2
:3
:4
A
M
AS103
LEVEL 3 FLOOR PLAN
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100
Indianapolis, IN 46204
(317) 800-6388
Apogee Consulting Group, PA
1511 Kildaire Farm Road, Suite 120
Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 TS KN
BID DOCUMENT
NOT SPRINKLERED
Carl Walker, a Division ofWGI
8910 Purdue Road, Suite 400
Indianapolis, IN 46828
(317) 735-3349
SCALE: 3/32" = 1'-0"AS103
1 LEVEL 3 FLOOR PLAN
SS
S
1. ON FLAT ROOFS MAINTAIN MINIMUM SLOPE OF 1/4" PER FOOT ON ROOF.
PROVIDE TAPERED RIGID INSULATION CRICKETS AT 1/4" PER FOOT SLOPE.
2. REFER TO STRUCTURAL DRAWINGS FOR BEARING POINTS OF SLOPING
STRUCTURE.
3. ROOFING SUPPLIERS, MANUFACTURERS, & INSTALLERS SHALL REVIEW ALL
ROOFING DETAILS & ADVISE ARCHITECT ON ANY RECOMMENDED CHANGES.
UNLESS NOTIFIED OTHERWISE, ROOFING SUPPLIERS, MANUFACTURERS AND
INSTALLERS WILL BE ASSUMED TO HAVE REVIEWED AND APPROVED THE
DETAILS SHOWN.
4. PROVIDE FLASHING AT ALL CONDUIT & HVAC LINES PENETRATING THE ROOF.
5. CONTRACTOR & ALL SUBTRADES SHALL BE AWARE & EXERCISE THE
NECESSARY CARE TO PREVENT DAMAGE TO OR PUNCTURE OF THE ROOF.
THIS SHALL INCLUDE ALL DELETERIOUS MATERIALS, TOOLS.
ROOF PLAN NOTES
GENERAL ROOF PLAN NOTES
ROOFING MEMBRANE OVER TAPERED INSULATION, REFER TO
SPECIFICATIONS.
ROOF CRICKET.
NOT USED
METAL COPING, REFER TO SPECIFICATIONS.
OVERFLOW SCUPPER AND DOWNSPOUT, REFER TO SPECIFICATIONS.
EXHAUST FAN, REFER TO MECHANICAL DRAWINGS.
TAKE ROOF MEMBRANE UP 1'-0" MIN. TO TERMINATION BAR AND SEALANT.
1.
2.
3.
4.
5.
6.
7.
A A
B B
C C
AS121
AS121
A.A
A.1
1.2 1.4 1.7
B.7
7.8
AS203
AS401
AS401
AS601
A
A.A
A.1
1.2 1.4 1.7
1 1
AS311
TYP.
TYP.
AS601
TYP.
AS311
TYP.
1/4" / 12" 1/4" / 12"
1/4" / 12"
AS402
AS402
C
B.7
7.8
TYP.
/4
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
M/E/P Engineers: Structural Engineer:
C U s e rs
\t s a n d e rs
\D o c u m e n ts
\1 .1
V A
N o rt h C h ic a g o ts a n d e rs g u id o n d e s ig n .c o m
.r v t
/7
/2
:3
:4
A
M
AS121
ROOF PLAN
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100
Indianapolis, IN 46204
(317) 800-6388
Apogee Consulting Group, PA
1511 Kildaire Farm Road, Suite 120
Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 TS KN
BID DOCUMENT
NOT SPRINKLERED
Carl Walker, a Division ofWGI
8910 Purdue Road, Suite 400
Indianapolis, IN 46828
(317) 735-3349
SCALE: 1/16" = 1'-0"AS121
1 ROOF PLAN
SCALE: 1/4" = 1'-0"AS121
2 ENLARGED ROOF PLAN - STAIR #1
SCALE: 1/4" = 1'-0"AS121
3 ENLARGED ROOF PLAN - STAIR #2
LEVEL 1
716' - 4"
LEVEL 2
727' - 8"
LEVEL 3
739' - 0"
A B C
A.A
A.1
AS311
FD-1, TYP.
AS203
FD-1, TYP.
9' - 7 1/4" 3' - 0 3/4" 6' - 0" 2' - 0" 6' - 0" 2' - 0"2' - 0" 5' - 0" 6' - 0" 2' - 0"2' - 0" 6' - 8"
3' - 4 1/4"
6' - 8" 2' - 0"
2' - 0" 6' - 0" 1' - 0"
2' - 0" 2' - 8" 8' - 0" 1' - 4" 6' - 0" 2' - 0"
2' - 0" 4' - 0" 2' - 0" 6' - 0" 2' - 0" 5' - 0"
8'
" 8'
OPEN TO BEYOND
OPEN TO BEYOND
8' - 8" 8' - 8" 8' - 8" 10' - 5" 7' - 7"
CJCJ
CJ TYP.
CJ,
TYP.
AS312
CJCJ
36' - 0"
MP-1
3' - 8" 6' - 0" 3' - 0" 6' - 0" 2' - 0" 6' - 0" 2' - 0"
2' - 0"
5' - 0" 6' - 0" 2' - 0" 2' - 0"
6' - 8"
4'
4'
4'
LEVEL 1
716' - 4"
LEVEL 2
727' - 8"
LEVEL 3
739' - 0"
2345678 11.21.41.7
AS311
CP-1, TYP.
PC-1, TYP. PC-2, TYP.
FD-1, TYP.
AS203
3'
4'
EQ. 2' - 0" EQ.
5'
5'
6'
7'
7'
9' - 8" 2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0" 9' - 8"
5' - 0"
2' - 0"
2' - 0" 2' - 0"
6' - 8"2' - 0"6' - 0" 2' - 0"
1' - 8"
2' - 0"
2' - 0"
2' - 0"
2' - 0"9' - 8"
2' - 0"
2' - 0"
2' - 0"
5' - 8"5' - 4" 6' - 0" 5' - 0" 2' - 0"2' - 0"2' - 0"2' - 0"2' - 0" 5' - 0" 6' - 0" 5' - 4"
29' - 4"
4'
5' - 8" 2' - 0"
2' - 0" 2' - 0"
9' - 8" 2' - 0"
2' - 0"
2' - 0"
2' - 0"
OPEN TO BEYONDOPEN TO BEYOND
OPEN TO BEYOND
OPEN TO BEYOND
OPEN TO BEYOND
OPEN TO BEYONDOPEN TO BEYOND
4'
4 '
4'
4'
4'
4'
EQEQEQ EQEQEQ
EQEQEQ
EQEQEQ
EQEQEQEQEQEQ
CJCJ
CJCJCJCJCJCJCJCJCJCJ
RJ TYP. RJ TYP.
RJ TYP.
RJ TYP.
RJ TYP.
RJ TYP.RJ TYP.
3'
EQ. 2' - 0" EQ.5' - 0"
2' - 0"
2' - 0" 2' - 0"
6' - 8"2' - 0"6' - 0"2' - 0" 1' - 8"
RJ TYP. RJ TYP.
4 '
EXTERIOR FINISH LEGEND
NOTE: CONCRETE FINISH SHALL BE PC-1 UNLESS NOTED OTHERWISE
PRECAST CONCRETE (RED TO MATCH BRICK)
RE: SCHEDULE FOR FINISHES SPEC. SECTION
DESCRIPTIONCODE
PC-2
FALL DETERRENT SCREENSFD - 1
PRECAST CONCRETE
RE: SCHEDULE FOR FINISHES SPEC. SECTION
PC-1
PRECAST CONCRETE COPING, REFER TO SPECIFICATIONSMC-1
CAST IN PLACE CONCRETE - ALL EXPOSED
SURFACES TO BE RUBBED FINISH
RE: SCHEDULE FOR FINISHES SPEC. SECTION
CP-1
REFERS TO SHEETS AS201, AS202, AS203, AS204, AND AS205
CJ CONTROL JOINT, REFER TO DETAIL ON SHEET 10/AS311CJ
MP-1 METAL PANEL, REFER TO SPECIFICATIONS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
M/E/P Engineers: Structural Engineer:
C U s e rs
\t s a n d e rs
\D o c u m e n ts
\1 .1
V A
N o rt h C h ic a g o ts a n d e rs g u id o n d e s ig n .c o m
.r v t
/7
/2
:3
:5
A
M
AS201
BUILDING ELEVATIONS
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100
Indianapolis, IN 46204
(317) 800-6388
Apogee Consulting Group, PA
1511 Kildaire Farm Road, Suite 120
Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 TS KN
BID DOCUMENT
NOT SPRINKLERED
Carl Walker, a Division ofWGI
8910 Purdue Road, Suite 400
Indianapolis, IN 46828
(317) 735-3349
SCALE: 1/8" = 1'-0"AS201
2 WEST ELEVATION
SCALE: 1/8" = 1'-0"AS201
1 NORTH ELEVATION
NOT TO SCALEAS201
3 3D NORTHWEST ISOMETRIC
EXTERIOR FINISH LEGEND
NOTE: CONCRETE FINISH SHALL BE PC-1 UNLESS NOTED OTHERWISE
PRECAST CONCRETE (RED TO MATCH BRICK)
RE: SCHEDULE FOR FINISHES SPEC. SECTION
DESCRIPTIONCODE
PC-2
FALL DETERRENT SCREENSFD - 1
PRECAST CONCRETE
RE: SCHEDULE FOR FINISHES SPEC. SECTION
PC-1
PRECAST CONCRETE COPING, REFER TO SPECIFICATIONSMC-1
CAST IN PLACE CONCRETE - ALL EXPOSED
SURFACES TO BE RUBBED FINISH
RE: SCHEDULE FOR FINISHES SPEC. SECTION
CP-1
REFERS TO SHEETS AS201, AS202, AS203, AS204, AND AS205
CJ CONTROL JOINT, REFER TO DETAIL ON SHEET 10/AS311CJ
MP-1 METAL PANEL, REFER TO SPECIFICATIONS
LEVEL 1
716' - 4"
LEVEL 2
727' - 8"
LEVEL 3
739' - 0"
ABC
AS311
B.7
AS203
5 PL-1
FD-1
PC-2
CP-1
4'
LEVEL 1 @ ST#2
719' - 1"
5' - 9" 2' - 0"2' - 0" 6' - 8" 2' - 0" 4' - 0" 3' - 0" 2' - 0"2' - 0" 5' - 0" 2' - 0" 2' - 8" 4' - 8" 2' - 0"2' - 0"2' - 0" 6' - 0" 4' - 4" 5' - 0" 2' - 0" 5' - 0" 2' - 0" 6' - 0" 2' - 0" 6' - 8" 2' - 0"2' - 0"2' - 0" 5' - 0"
7'
7'
LEVEL 2 @ ST#2
730' - 5"
OPEN TO BEYONDOPEN TO BEYOND
EQ EQ EQ EQ
EQ EQ
CJ
CJ CJ CJ
CJ TYP.CJ TYP.
LEVEL 1
716' - 4"
LEVEL 2
727' - 8"
LEVEL 3
739' - 0"
2 3 4 5 6 7 81 1.2 1.4 1.7
AS311
AS311
AS311
AS312
7.8
AS204
37' - 0"
LEVEL 1 @ ST#2
719' - 1"
4'
T Y
P
4'
47' - 0"
2'
1'
6'
7'
4' - 0"2' - 0"2' - 0"2' - 0"9' - 8"2' - 0"2' - 0"2' - 0"3' - 7 1/4"
9' - 8"
2' - 0"2' - 0"
2' - 0"
2' - 0"2' - 0"
9' - 8"
3' - 7"2' - 0"2' - 0"2' - 0"6' - 8"2' - 0"6' - 0"2' - 0"3' - 0"
3' - 5" 2' - 0"2' - 0"2' - 0" 9' - 8" 2' - 0"2' - 0"2' - 0" 4' - 3"9' - 8"2' - 0"2' - 0"
2' - 0"
2' - 0"2' - 0"9' - 8"
LEVEL 2 @ ST#2
730' - 5"
OPEN TO BEYOND
OPEN TO BEYOND
OPEN TO BEYOND
OPEN TO BEYOND
OPEN TO BEYOND
OPEN TO BEYOND
4 ' - 9 "
4'
4'
EQ EQ EQEQ EQ EQ
EQEQEQEQEQEQ9' - 7" 10' - 0" 9' - 8"
EQEQEQEQ
CJCJCJCJCJCJ
CJCJCJCJ
CJCJCJCJ
RJ TYP.
RJ TYP.
RJ TYP.RJ TYP.
RJ TYP.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
M/E/P Engineers: Structural Engineer:
C U s e rs
\t s a n d e rs
\D o c u m e n ts
\1 .1
V A
N o rt h C h ic a g o ts a n d e rs g u id o n d e s ig n .c o m
.r v t
/7
/2
:3
:0
A
M
AS202
BUILDING ELEVATIONS
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100
Indianapolis, IN 46204
(317) 800-6388
Apogee Consulting Group, PA
1511 Kildaire Farm Road, Suite 120
Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 TS KN
BID DOCUMENT
NOT SPRINKLERED
Carl Walker, a Division ofWGI
8910 Purdue Road, Suite 400
Indianapolis, IN 46828
(317) 735-3349
NOT TO SCALEAS202
3 3D SOUTHEAST ISOMETRIC
SCALE: 1/8" = 1'-0"AS202
2 EAST ELEVATION
SCALE: 1/8" = 1'-0"AS202
1 SOUTH ELEVATION
PRECAST CONCRETE (RED TO MATCH BRICK)
RE: SCHEDULE FOR FINISHES SPEC. SECTION
DESCRIPTIONCODE
PC-2
FALL DETERRENT SCREENSFD - 1
PRECAST CONCRETE
RE: SCHEDULE FOR FINISHES SPEC. SECTION
PC-1
PRECAST CONCRETE COPING, REFER TO SPECIFICATIONSMC-1
CAST IN PLACE CONCRETE - ALL EXPOSED
SURFACES TO BE RUBBED FINISH
RE: SCHEDULE FOR FINISHES SPEC. SECTION
CP-1
REFERS TO SHEETS AS201, AS202, AS203, AS204, AND AS205
CJ CONTROL JOINT, REFER TO DETAIL ON SHEET 10/AS311CJ
MP-1 METAL PANEL, REFER TO SPECIFICATIONS
LEVEL 1
716' - 4"
LEVEL 2
727' - 8"
LEVEL 3
739' - 0"
ROOF PLAN
750' - 3"
Level 4 748' - 3"
AS401
A
A.AA.1
LEVEL 1
716' - 4"
LEVEL 2
727' - 8"
LEVEL 3
739' - 0"
ROOF PLAN
750' - 3"
Level 4 748' - 3"
AS401
A
MC, TYP.
2'
8'
2'
8'
2'
8'
A.A A.1
PC-2, TYP.
SF-1
SF-1
SF-1
SF-1
9/
8"
SIM. SIM.
PC-1, TYP.
SF-1 SF-1
LEVEL 1
716' - 4"
LEVEL 2
727' - 8"
LEVEL 3
739' - 0"
AS401
SF-1
SF-1
SF-3
2' - 8" 8' - 0" 2' - 8" 7' - 0" 2' - 8" 7' - 11"
101A
1.21.41.