36C25219B0038-005.pdf
PDF 10 MB Posted
- Attached to
- 556-305, Construct New Parking Garage Federal contract opportunity
- Solicitation number
- 36C25219B0038
About this file
36C25219B0038 Bid Documents Drawings Part 1 of 2 2-20-20 - REV 1.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25219B0038-0007001.pdf | ||
| 36C25219B0038-0007000.docx | DOCX document | |
| 36C25219B0038-0006000.docx | DOCX document | |
| 36C25219B0038-0005000.docx | DOCX document | |
| 36C25219B0038-0005001.pdf | ||
| 36C25219B0038-0005002.pdf | ||
| 36C25219B0038-0004000.docx | DOCX document | |
| 36C25219B0038-0003005.pdf | ||
| 36C25219B0038-0003008.pdf | ||
| 36C25219B0038-0003002.pdf | ||
| 36C25219B0038-0003001.pdf | ||
| 36C25219B0038-0003004.pdf | ||
| 36C25219B0038-0003006.pdf | ||
| 36C25219B0038-0003009.pdf | ||
| 36C25219B0038-0003010.pdf | ||
| 36C25219B0038-0003000.docx | DOCX document | |
| 36C25219B0038-0003007.pdf | ||
| 36C25219B0038-0003003.pdf | ||
| 36C25219B0038-0002000.docx | DOCX document | |
| 36C25219B0038-0001001.pdf | ||
| 36C25219B0038-0001000.docx | DOCX document | |
| 36C25219B0038-003.pdf | ||
| 36C25219B0038-004.pdf | ||
| 36C25219B0038-001.docx | DOCX document | |
| 36C25219B0038-006.pdf | ||
| 36C25219B0038-002.pdf | ||
| 36C25219B0038-000.docx | DOCX document |
Show all 27
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PARKING SUMMARY
DESCRIPTION STANDARD COMPACT ADA ADA VAN TOTAL
LEVEL 3 34 0 0 0 34
STANDARD SPACE = 9'-0" X 18'-0" @ 90°
ADA = 8'-0" X 18'-0" W/5'-0" ACCESSIBLE AISLE @ 90°
ADA VAN = 11'-0" X 18'-0" W/5'-0" ACCESSIBLE AISLE @ 90°
LEVEL 2 96 1 0 0 97
LEVEL 1 81 1 0 0 82
TOTAL 211 2 0 0 213
PROJECT SITE
AREA MAP
VICINITY MAP
DEDUCTIVE BID ALTERNATES
ALL WORK IN THE BASE BID MINUS ELECTRIC VEHICLE CHARGING STATIONS; SLEEVES
FOR FUTURE INSTALLATION SHALL REMAIN IN SCOPE. REFER TO ELECTRICAL
DRAWINGS.
ALL WORK IN ALTERNATE BID ITEM A MINUS FALL DETERRENT. REDUCE THE HEIGHT
OF ASSOCIATED COLUMNS TO MATCH ADJACENT STRUCTURAL ELEMENTS.
ALL WORK IN ALTERNATE BID ITEM B MINUS ELEVATOR, ALL ASSOCIATED EQUIPMENT,
AND DOORS TO ACCESS ELEVATOR. REFER TO ELECTRICAL DRAWINGS. OPENINGS IN
CMU WALL SHALL BE CONSTRUCTED AS INDICATED TO ACCOMMODATE THE FUTURE
PROVISION OF ELEVATOR AND SHALL BE FULLY INFILLED. WALL FINISH SHALL BE
INSTALLED WHERE ELEVATOR DOOR WAS TO BE INSTALLED.
ALL WORK IN ALTERNATE BID ITEM C EXECPT PROVIDE PRE-TOPPED SLAB IN LIEU OF
FIELD-TOPPED. REFER TO STRUCTURAL DRAWINGS.
ALL WORK IN ALTERNATE BID ITEM D MINUS CONSTRUCTION PAST COLUMN LINE '2' ON
THE 2ND TIER, BY APPROXIMATELY 20 PARKING SPACES. THIS INCLUDES THE
REMOVAL OF ALL ASSOCIATED ELEMENTS INCLUDING THE 3RD LEVEL OF ELEVATOR
AND STAIR TOWER, DOORS, STAIRS, WINDOWS, ETC. CONTRACTOR SHALL ENSURE
THAT CERTAIN ELEMENTS REQUIRED AT THE TOP LEVEL OF THE GARAGE SHALL BE
MOVED TO THE 2ND TIER, INCLUDING LIGHTS, SNOW REMOVAL GATE, ROOFS, ROOF
DRAINS, AND SIMILAR ITEMS. TO ACCOMMDATE THIS CHANGE, A ROOF SHALL BE
REQUIRED ABOVE THE ELEVATOR CONTROL ROOM ON THE 2ND TIER, INCLUDING A
SCUPPER, AND AN EGRESS STAIR SHALL BE REQUIRED AT THE TOP OF THE 2ND TIER.
PRICING SHALL INCLUDE ALL NECESSARY ELEMENTS.
A.
B.
C.
D.
E.
REFER TO DRAWINGS FOR ADDITIONAL INFORMATION.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
M/E/P Engineers: Structural Engineer:
C U s e rs
\K n ie h a u s \D o c u m e n ts
\1 .1
V A
N o rt h C h ic a g o k n ie h a u s g u id o n d e s ig n .c o m
.r v t
/5
/2
:0 :5
A
M
GI100
COVER SHEET
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100
Indianapolis, IN 46204
(317) 800-6388
Apogee Consulting Group, PA
1511 Kildaire Farm Road, Suite 120
Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 TS KN
BID DOCUMENT
NOT SPRINKLERED
Carl Walker, a Division ofWGI
8910 Purdue Road, Suite 400
Indianapolis, IN 46828
(317) 735-3349
SHEET LIST
SHEET
NUMBER SHEET NAME
GENERAL
GI100 COVER SHEET
GI101 CODE ANALYSIS
GI102 LIFE SAFETY PLANS
CIVIL
CI001 GENERAL NOTES
VF101 TOPOGRAPHIC MAP
CD101 DEMOLITION PLAN
CS101 SITE PLAN
CS102 ROUNDABOUT MODIFICATIONS PLAN
CS501 SITE DETAILS
CS502 SITE DETAILS
CG101 GRADING PLAN
CU101 UTILITY PLAN
CU501 UTILITY DETAILS
CU502 UTILITY DETAILS
CJ101 EROSION CONTROL PLAN
CJ501 EROSION CONTROL DETAILS
CW101 SITE WAYFINDING PLAN
CW501 SITE WAYFINDING DETAILS
STRUCTURAL
SI001 GENERAL NOTES
SI002 GENERAL NOTES
SI003 LOAD INFORMATION
SI004 FUTURE EXPANSION INFORMATION
SB100 FOUNDATION PLAN - STRUCTUURAL
SB501 FOUNDATION & SLAB ON GRADE DETAILS - STRUCTURAL
SB502 FOUNDATION DETAILS - STRUCTURAL
SB601 FOUNDATION SCHEDULE & TYPICAL DETAILS - STRUCTURAL
SF101 LEVEL 1 PLAN - STRUCTURAL
SF102 LEVEL 2 PLAN - STRUCTURAL
SF103 LEVEL 3 PLAN - STRUCTURAL
SF201 STRUCTURAL ELEVATIONS
SF301 BUILDING SECTIONS - STRUCTURAL
SF401 NORTHWEST STAIR-ELEVATOR ENLARGED PLANS - STRUCTURAL
SF411 SOUTHEAST STAIR-ELEVATOR ENLARGED PLANS - STRUCTURAL
SF511 PCC COLUMN DETAILS - STRUCTURAL
SF521 PCC FRAMING DETAILS - STRUCTURAL
SF522 PCC FRAMING DETAILS - STRUCTURAL
SF531 TYPICAL PCC BEAM DETAILS - STRUCTURAL
SF532 PCC WALL & CONNECTION DETAILS - STRUCTURAL
SF541 WATERPROOFING DETAILS - STRUCTURAL
SF551 STANDARD & MISCELLANEOUS DETAILS - STRUCTURAL
SF561 ENLARGED PLAN DETAILS - STRUCTURAL
SF562 ENLARGED PLAN DETAILS - STRUCTURAL
SF563 ENLARGED PLAN DETAILS - STRUCTURAL
SF611 LOADING DIAGRAMS - STRUCTURAL
ARCHITECTURE
AS001 ARCHITECTURE SYMBOLS AND ABBREVIATIONS
AS101 LEVEL 1 FLOOR PLAN
AS102 LEVEL 2 FLOOR PLAN
AS103 LEVEL 3 FLOOR PLAN
AS121 ROOF PLAN
AS201 BUILDING ELEVATIONS
AS202 BUILDING ELEVATIONS
AS203 ENLARGED BUILDING ELEVATIONS - ST#1
AS204 ENLARGED BUILDING ELEVATIONS - ST#2
AS311 WALL SECTIONS AND DETAILS
AS312 STAIR SECTIONS, RAILING ELEVATIONS, AND DETAILS
AS401 ENLARGED PLANS AND STAIR SECTIONS - ST#1
AS402 ENLARGED PLANS AND STAIR SECTIONS - ST#2
AS601 OPENINGS SCHEDULES AND DETAILS
FUNCTIONAL
AP101 LEVEL 1 PLAN - ARCHITECTURAL PARKING
AP102 LEVEL 2 PLAN - ARCHITECTURAL PARKING
AP103 LEVEL 3 PLAN - ARCHITECTURAL PARKING
AP501 STRIPING & PAINTED GRAPHICS - ARCHITECTURAL PARKING
AP511 SIGN MOUNTING DETAILS - ARCHITECTURAL PARKING
PLUMBING
PP001 PLUMBING LEGEND, ABBRV'S, AND GENERAL NOTES
PP100 FOUNDATION PLUMBING PLAN
PP101 LEVEL 1 PLUMBING PLAN
PP102 LEVEL 2 PLUMBING PLAN
PP103 LEVEL 3 PLUMBING PLAN
PP901 PLUMBING RISER
MECHANICAL
MH001 MECHANICAL NOTES, DETAILS, AND LEGEND
MH401 MECHANICAL PLAN, DETAILS, AND SCHEDULES
ELECTRICAL
EE001 ELECTRICAL NOTES, LEGENDS AND LIGHT FIXTURE SCHEDULE
ES101 ELECTRICAL SITE PLAN
EE101 LEVEL 1 ELECTRICAL PLAN
EE102 LEVEL 2 ELECTRICAL PLAN
ES103 LEVEL 3 ELECTRICAL PLAN
EE401 ELECTRICAL ENLARGEMENTS
EE501 ELECTRICAL DETAILS
EE502 ELECTRICAL DETAILS AND LAN RISERS
EE601 ELECTRICAL SINGLE-LINE AND SCHEDULES
THE CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, ILLINOIS
CONSTRUCT NEW PARKING GARAGE
Contact:Contact:
APOGEE CONSULTING GROUP, PA
Alex Kramer
Engineer
MECHANICAL,
ELECTRICAL &
PLUMBING
CARL WALKER, A DIVISION OF WGI
STRUCTURAL
ENGINEER
GUIDON DESIGN INC.
CIVIL
ENGINEER
FEDERAL HEALTH CARE SYSTEM
Gregory Fowler
Project COR
3001 Green Bay Rd.
North Chicago, IL 60068 p: 224 610 3572 e: Gregory.Fowler@va.gov
OWNER
GUIDON DESIGN INC.
ARCHITECT
1511 Kildaire Farm Road, Suite 120 Cary, NC 27511 p:919-535-3958 e: akramer@acg-pa.com
Contact:Contact:Contact:
Doug Gannon
Structural Engineer
Kyle Cyr
Project Manager
905 North Capitol Avenue Suite 100 Indianapolis, IN 46204 p: 317.800.6388 x 110 e: kcyr@guidondesign.com
Tyler Sanders
Architect
905 North Capitol Avenue Suite 100 Indianapolis, IN 46204 p: 317.800.6388 x 126 e: tsanders@guidondesign.com
8910 Purdue Road Suite 400 Indianapolis, IN 46268 p: 317-860-5133 e: dgannon@wginc.com
BID DOCUMENT
Revisions: Date:
GOVERNING CODES:
ICC, International Building Code, 2015 edition (IBC) NFPA 101, Life Safety Code, 18th edition, 2018 (LSC) NFPA 10, Standard for Portable Fire Extinguishers, 18th edition, 2017 NFPA 14, Standard for the Installation of Standpipe and Hose System, 2016 edition NFPA 24, Standard for the Installation of Private Fire Service Mains and their Appurtenance, 2016 edition NFPA 72, National Fire Alarm Code, 2016 edition NFPA 70, National Electric Code, 17th edition, 2017 NFPA 80, Standard for Fire Doors and Other Opening Protectives, 16th edition, 2016 NFPA 88A, Standard for Parking Structures, 2015 edition NFPA 90A, Standard for the Installation of Air-Conditioning and Ventilating Systems, 2018 ediition NFPA 220, Standard Types of Building Construction, 2018 edition NFPA 291, Recommended Practice for Fire Flow Testing and Marking of Hydrants, 2016 edition ASTM E2072-04, Specification for Photoluminescent (Phosphorescent) Safety Markings, 2014 edition
International Plumbing Code 2015 edition ASHRAE 90.1 IP -2016 edition
ASHRAE 62.1 – 2016
ICC A117.1 Standard on Accessible & Usable Buildings and Facilities 2017 2010 ADA Standards for Accessible Design
ASCE-07-10
ACI 318-14
ACI 530-13
AISC 341-10
AISC 360 2016 edition PCI MNL 120, Design Handbook 7th edition, 2012
VA Parking Design Manual & Demand Model, April 2013 VA Barrier Free Design Guide Architectural Electrical
HVAC
Plumbing Site and Landscape Auto Transport Interior Design Structural Sanitary Fire Protection, Seventh Edition December 2015 Facilities Physical Security Design Manual: Life-Safety Protected Sustainability Guidelines
VA DESIGN MANUALS:
A. OCCUPANCY CLASSIFICATION
1. The parking garage is classified as low-hazard storage facilities, a Group S-2 Occupancy, and as an ordinary hazard by NFPA 101 42.8.1.5
2. The parking garage is considered an OPEN PARKING STRUCTURE openings shall comply with the following:
a. Open Parking Structure: A parking structure that meets the requirements of NFPA 88A Section 5.5
i. Each parking level shall have wall openings to the atmosphere for an area of not less than 1.4 square feet for each linear foot of the exterior perimeter.
ii. Opening shall be distributed over a minimum of 40% of the building perimeter or uniformly over two opposing sides.
iii. Interior wall lines and columns shall be at least 20% open, with openings distributed to provide ventilation.
3. This parking garage is classified as a Ramp Type Parking Structure: A parking Structure that utilizes sloped ramps for vertical vehicle circulation per NFPA 88A 4.1.3
B. CONSTRUCTION CLASSIFICATION
1. The parking garage is to be constructed in accordance with the provisions of NFPA 88A as defined in NFPA 220.
Construction type for a building exceeding 25 feet in height shall be Type I, Type II(222) or Type II(111). An open parking garage of these construction types may be unlimited in height and area. In addition, per NFPA 88 5.1.4, Type II(000) is permitted to be of unlimited area where both the height does not exceed 75 feet and the horizontal distance from any point on any parking level to an exterior wall opening on a street, an alley, a courtyard or other similar permanent open space does not exceed 200 feet.
2. The Parking Garage has two levels above grade and is classified as an open parking structure. The construction classification is Type II(000) based upon the occupancy and area of the building.
3. Primary structural elements of Type II(000) buildings are not required to be rated. Primary structural elements supporting a roof are not required to be rated, and all floor construction are not required to be rated.
NFPA 220 Table 4.1.1
4. Primary structural members are considered to be bearing walls, columns, and the girders, beams, trusses and spandrels having direct connections to columns and bracing members designed to carry gravity loads. The members of floor or roof panels which have no connection to the columns and do not carry a gravity load are considered secondary members and are not part of the structural frame of a building
C. FIRE RESISTANCE RATED SEPARATIONS
The Garage will be designed as nonseparated mixed uses. Incidental uses are not anticipated, so no fire rated separation is required between occupancies. Interior building elements that require fire resistance ratings are listed below:
BUILDING ELEMENT FIRE RESISTANCE RATING CODE REFERENCE
Non-enclosed Exit Stairs (Provided) 0 NFPA 88A, 4.1.5 Enclosed Exit Stairs (NOT PROVIDED) 1,2 NFPA 101 7.1.3.2.1
Ramps 0 NFPA 101 42.8.3.1.2
Other shafts which connect 2 or more stories 2 NFPA 101 42.8.3.1.2
Elevator machine rooms 2 NFPA 101 7.15.7.1
Emergency generator (if provided) 2 NFPA 70
(1) Supporting structural members (located within one structural bay) must have the same fire resistance rating. The fire resistance rating must be carried through all structural members; extending to the foundation. In addition, the shaft construction must maintain the same fire rating as the floor construction (1 Hr rated).
(2) Where nonrated walls or unprotected openings enclose the exterior of the stairway and the walls or openings are exposed by other parts of the building at an angle of less than 180 degrees, the building exterior walls within
3.048 m (10 ft) horizontally of a nonrated wall or unprotected opening must have a fire resistance rating of not less than 1-hour. Openings within such exterior walls must be protected by opening protectives having a fire protection rating of not less than ¾-hour. This construction must extend vertically from the ground to a point 3.048 m (10 ft) above the top most landing of the stairway or to the roof line, whichever is lower.
1. Mechanical equipment rooms incidental to the use of the building are not required to be separated by an occupancy separation. Special hazard rooms such as general storage and furnace/boiler rooms and electrical switchgear rooms shall be separated per NFPA 70 and potentially IBC Table 508.2.
2. Cashier and attendant booths are not required to be separated. NFPA 88A 5.2.4.
3. The electrical, security and IT rooms do not have a total area exceeding 3,000 SF therefore shall be separated by partitions built to resist the passage of smoke. NFPA 88A 5.2.4.
4. Fire barriers will extend from the top of the floor below to the underside of the floor or roof deck above. The openings and penetrations in required exit enclosures will be protected with self-closing or automatic-closing opening protectives. Openings in fire resistance rated walls will be protected in accordance with the following:
COMPONENT WALLS AND PARTITIONS FIRE DOOR ASSEMBLIES
(HR) NFPA 101 8.3.4.2 (HR/MIN) NFPA 101 8.3.4.2
Elevator Machine Rooms 2 (NFPA 7.14.7.1) 1.5(90)
Vertical Shafts (including enclosed exit stairways)0 (NFPA 101 42.8.3.1.2) 0
Fire Barriers 1 .75(45) 2 1.5(90) 3 3(180)
Piping, conduit, and wire penetrations of fire rated construction will be protected by materials or systems of the same hourly rating listed by Underwriters Laboratories (UL), Factory Mutual (FM), or a National Recognized Testing Laboratory (NRTL). Duct, air transfer openings, and other penetrations through floors, shaft enclosures and other fire rated construction will be protected in accordance with the LSC and the IBC.
CODE ANALYSIS
D. BUILDING PLACEMENT
The code requires the exterior walls of buildings to be protected from one another based on the fire separation distance between buildings, or to a lot line. Fire separation distance is defined as the distance measured from the face of a building to one of the following three points:
1. The closest interior lot line;
2. To the centerline of a street, an alley or public way, or;
3. To an imaginary line between two buildings on the property.
No fire rated separation is required where the parking structure is separated by 10 feet. NFPA 88A 5.2.2
E. INTERIOR FINISH
Interior wall and ceiling finish to be designed in accordance with the NFPA 101, 42.8.3.3.3.
1. Class A, B and C finish is permitted for interior walls and ceilings in rooms, and corridors. Class A or B finish is permitted for exits.
2. Per the IBC Section 406.2.6 all floor surfaces shall be of concrete or other similar non-combustible and non-absorbent materials. Floor Finish shall not be less than Class II.
F. EGRESS LIGHTING AND EXIT SIGNAGE
Emergency egress lighting will be provided throughout the common portions of the means of egress in accordance with The Life Safety Code Code section 42.8.2.8, 42.8.2.9 and 42.8.2.10.
1. These areas include drive lanes, corridors, exit access spaces within areas requiring two (2) or more means of egress, the lobby/entrance areas, exit stairs, and the exit discharge areas (including exterior locations until the public way).
2. Each required exit will be identified with an exit sign, including exit access, and within areas requiring multiple exits. Directional exit signs will also be provided to direct occupants toward the closest exit so that no occupant is more than 100 feet from an exit sign.
3. The egress lighting and exit signs will be provided with a secondary source of power in the event that the primary power source is disrupted. The secondary power source will consist of either internal batteries or a connection to an emergency power system.
G. MEANS OF EGRESS
Means of egress shall be in compliance with NFPA 101 and as modified by NFPA 88A. Egress requirements are based upon a non-sprinklered building. Exits must be so located on each story such that the maximum length of exit access travel, measured from the most remote point within a story along the natural and unobstructed path of egress travel to an exterior exit door at the level of exit discharge, an entrance to a vertical exit enclosure, an exit passageway, a horizontal exit, an exterior exit stairway or an exterior exit ramp, may not exceed the distances allowed by the Code.
Egress requirements are outlined below.
1. Maximum travel distance: open parking garage – 300 feet ( NFPA 101 Table 42.8.2.6.1 )
2. Common path of travel: 50 feet ( NFPA 101 Table 42.8.2.5.1 )
3. Dead ends: 50 feet ( NFPA 101 Table 42.8.2.5.2 )
4. Number of exits: At least two exits shall be provided from every floor/tier. In certain conditions ramps may be substituted for an egress stair. ( NFPA 101 Table 42.8.2.4 )
5. Egress Width Factor: NFPA 101 Table 7.3.3.1 requires a minimum egress width of 0.2 in per occupant for doors, ramps, and corridors and a minimum egress width of 0.3 in per occupant for stairs.
6. Occupant Load factor: NFPA 101 Table 7.3.1.2 requires an Occupant load factor of 500 s.f. per person be applied to storage use type facilities other than storage and mercantile occupancies. Parking garages are classified by chapter 42 of the NFPA 101 as storage type occupancies. IBC Table 1004.1.2 requires an occupant load factor of 200 for parking garages
7. Remoteness of exits: Where two or more exits or exit access doorways are required from any portion of the exit access, at least two of the exit doors or exit access doorways must be placed a distance apart equal to not less than one-half of the length of the maximum overall diagonal dimension of the building or area to be served measured in a straight line between exit doors or exit access doorways.
8. Stairs Design ( per theNFPA 101 7.2.2):
9. Maximum Riser Height: 7 inches (NFPA 101 Table 7.2.2.2.1.1(a))
Minimum Tread Length: 11 inches (NFPA 101 Table 7.2.2.2.1.1(a)) Minimum Stair Width: 44 inches (NFPA 101 Table 7.2.2.2.1.2(B)) Guard: 42 inches( Required where elevation change exceeds 30 inches. Design shall prevent the passage of a 4 inch Sphere.) (NFPA 101 7.2.2.4.6.2) Handrail: 34-38 inches (NFPA 101 7.2.2.4.5.1) Minimum Clearance: 6 feet 8 inches (Measured vertically from nose of tread.)
Signage: Required at each floor level (NFPA 101 7.2.2.5.4)
10. Ramp Design: per the NFPA 101 7.2.5):
Maximum Slope: 1/12 (NFPA 101 Table 7.2.5.3(a)) Guard: 42 inches(Required where elevation change exceeds 30 inches. Design shall prevent the passage of a 4 inch Sphere.) (NFPA 101 7.2.2.4.6.2) 4 inch curbs required for drop off edge of ramp
Handrail: 34-38 inches (required for ramps with more than a 6 inch rise) (NFPA 101 7.2.2.4.5.1)
11. Areas Of Refuge: Not required in open parking garages (NFPA 101 42.8.2.2.9.2)
H. EMERGENCY ELEVATOR OPERATION
Elevator will have a Smoke detector, located in its respective lobby, on each floor level where the lobby is enclosed. A heat detector is permitted where the lobby is open to the environment. Upon activation of a lobby heat detector or machine room smoke detector, the elevators served by that lobby or machine room will be recalled to the main level of the building, one at a time. In the event that the alarm is on this designated level, the elevators will be recalled one at a time to an alternate level. It is proposed to recall only the elevator or group of elevators served by the affected lobby or elevator machine room.
After returning to the appropriate level, the elevators will stop, the doors will open, and the elevators will be rendered inoperable without the use of the fireman's key or until such time that they are manually reset to the normal operating mode. This mode of operation is provided for fire department use to allow for access to all levels served by the elevators.
I. Automatic Sprinkler System Not required in open parking garages (NFPA 101 42.8.3.5 and NFPA 88A 6.4.4)
J. Standpipes Class I Standpipes are not required in open parking garages not exceeding 50 feet in height PER NFPA 88A 6.5.1
K. PORTABLE FIRE EXTINGUISHERS
1. Portable fire extinguishers will be provided throughout the garages as required by IFC section 906.1 and spaced in accordance with NFPA 10, 2013 edition. 75' Spacing
L. Fire alarm system Not required per NFPA 101 42.8.3.4.1.2. and IBC 907.2
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
M/E/P Engineers: Structural Engineer:
C U s e rs
\t s a n d e rs
\D o c u m e n ts
\1 .1
V A
N o rt h C h ic a g o ts a n d e rs g u id o n d e s ig n .c o m
.r v t
/1
/2
:2 :4
P
M
GI101
CODE ANALYSIS
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100
Indianapolis, IN 46204
(317) 800-6388
Apogee Consulting Group, PA
1511 Kildaire Farm Road, Suite 120
Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 TS KN
BID DOCUMENT
NOT SPRINKLERED
Carl Walker, a Division ofWGI
8910 Purdue Road, Suite 400
Indianapolis, IN 46828
(317) 735-3349
2 OF 80Revisions: Date:
STAMP
UP
L F
OF
FD
N
DR
AI
N
.5
DN
CODE ANALYSIS LEGEND
TOTAL OCCUPANCY
FE
EXIT
OCCUPANCY LOAD FACTOR
EXITS REQUIRED
SQUARE FOOTAGE
OCCUPANCY TYPE
EGRESS EXIT SIGNAGE
FIRE EXTINGUISHER
DIAGONAL DISTANCE
EXIT SEPARATION DISTANCE
SMOKE PARTITION
B
1500 SF
2 HR. - FIRE SEPARATION
208 SF
S
153 SF
S
94 SF
S
277 SF
S
DIAGONAL DISTANCE = 289'-2"
TRAVEL DISTANCE = 152'-6"
EXIT SEPARATION = 242'-0"
EXIT
EXIT
EXIT
139 SF
S
27355 SF
200137
S
EXIT
DISCHARGE AT
GRADE
DIAGONAL DISTANCE = 289'-2" EXIT SEPARATION = 242'-0"
TRAVEL DISTANCE = 149'-4"
EXIT
EXIT
30439 SF
200153
S
164 SF
S
79 SF
S
DIAGONAL DISTANCE = 289'-2"
2ND TIER LEVEL BELOW
EXIT SEPARATION = 242'-0"
TRAVEL DISTANCE = 162'-0"
EXIT BELOW
EXIT BELOW
11239 SF
20059
S
196 SF
S
ISOMETRIC KEYPLAN
LEVEL 2
+11'-4"
LEVEL 1
0'-0"
LEVEL 3
+22'-8"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
M/E/P Engineers: Structural Engineer:
C U s e rs
\t s a n d e rs
\D o c u m e n ts
\1 .1
V A
N o rt h C h ic a g o ts a n d e rs g u id o n d e s ig n .c o m
.r v t
/7
/2
:3
:3
A
M
GI102
LIFE SAFETY PLANS
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100
Indianapolis, IN 46204
(317) 800-6388
Apogee Consulting Group, PA
1511 Kildaire Farm Road, Suite 120
Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 TS KN
BID DOCUMENT
NOT SPRINKLERED
Carl Walker, a Division ofWGI
8910 Purdue Road, Suite 400
Indianapolis, IN 46828
(317) 735-3349
LIFE SAFETY OCCUPANCY
AREA SF OCC OCC FACTOR # OF OCC
Not Placed
ELEV MACHINE Not Placed S 200 1
0 SF 1
LEVEL 1
ELECTRICAL 208 SF S 200 1
OIT 153 SF S 200 1
SECURITY 94 SF S 200 1
STORAGE 277 SF S 200 2
LOBBY 139 SF S 200 1
PARKING 27355 SF S 200 137
28226 SF 143
LEVEL 2
PARKING 30439 SF S 200 153
LOBBY 164 SF S 200 1
Area 79 SF S 200 1
30682 SF 155
LEVEL 3
PARKING 11239 SF S 200 59
LOBBY 196 SF S 200 1
11435 SF 60
70343 SF 359
GROSS BUILDING AREA
FLOOR SF
LEVEL 1
GROSS FLOOR AREA 30111 SF
LEVEL 2
GROSS FLOOR AREA 32064 SF
LEVEL 3
GROSS FLOOR AREA 12325 SF
74499 SF
SCALE: 3/64" = 1'-0"GI102
1 LEVEL 1 LIFE SAFETY PLAN
SCALE: 3/64" = 1'-0"GI102
2 LEVEL 2 LIFE SAFETY PLAN
SCALE: 3/64" = 1'-0"GI102
3 LEVEL 3 LIFE SAFETY PLAN
NN
N
GENERAL NOTES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100 Indianapolis, IN 46204
(317) 800-6388
M/E/P Engineers:
Apogee Consulting Group, PA 1511 Kildaire Farm Road, Suite 120 Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 CMB DSMRevisions: Date:
Structural Engineer:
Carl Walker, Inc.
8910 Purdue Road, Suite 400 Indianapolis, IN 46268
(317) 735-3349
804 OF
CI001
CAVIN DRIVE
NOTES
Elevations refer to NAVD 1988 Datum.
Starting benchmark is HARN monument LAK137 1B with an elevation of 700.76 feet.
Horizontal coordinates refer to the North American Datum of 1983 (NAD83) State Plane Coordinate System.
( IN FEET )
GRAPHIC SCALE
0 40201010
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
VF101
TOPOGRAPHIC MAP
A
BID DOCUMENT
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Architect / Civil Engineer:
STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100 Indianapolis, IN 46204
(317) 800-6388
M/E/P Engineers:
Apogee Consulting Group, PA 1511 Kildaire Farm Road, Suite 120 Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
Project Director
1/9/2019 ERS CRWRevisions: Date:
Structural Engineer:
Carl Walker, Inc.
8910 Purdue Road, Suite 400 Indianapolis, IN 46268
(317) 735-3349
TOPOGRAPHIC MAP
CAPTAIN JAMES A LOVELL FEDERAL HEALTH CARE CENTER BEING PART OF THE SOUTHEAST
1/4 OF SECTION 8, TOWN 44 NORTH, RANGE 12 EAST, LAKE COUNTY, ILLINOIS.
AUGUST 4, 2017 GUIDON DESIGN DRAWING NO.167135 - CRW
C A
V
IN
D R
IV
E
0 4020
N
DEMOLITION PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100 Indianapolis, IN 46204
(317) 800-6388
M/E/P Engineers:
Apogee Consulting Group, PA 1511 Kildaire Farm Road, Suite 120 Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 CMB DSMRevisions: Date:
Structural Engineer:
Carl Walker, Inc.
8910 Purdue Road, Suite 400 Indianapolis, IN 46268
(317) 735-3349
806 OF
CD101
V
IN
D R
IV
E
0 4020
N
SITE PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100 Indianapolis, IN 46204
(317) 800-6388
M/E/P Engineers:
Apogee Consulting Group, PA 1511 Kildaire Farm Road, Suite 120 Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 CMB DSMRevisions: Date:
Structural Engineer:
Carl Walker, Inc.
8910 Purdue Road, Suite 400 Indianapolis, IN 46268
(317) 735-3349
807 OF
CS101
0 4020
N
ROUNDABOUT MODIFICATIONS
PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100 Indianapolis, IN 46204
(317) 800-6388
M/E/P Engineers:
Apogee Consulting Group, PA 1511 Kildaire Farm Road, Suite 120 Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 CMB DSMRevisions: Date:
Structural Engineer:
Carl Walker, Inc.
8910 Purdue Road, Suite 400 Indianapolis, IN 46268
(317) 735-3349
808 OF
CS102
SITE DETAILS
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100 Indianapolis, IN 46204
(317) 800-6388
M/E/P Engineers:
Apogee Consulting Group, PA 1511 Kildaire Farm Road, Suite 120 Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 CMB DSMRevisions: Date:
Structural Engineer:
Carl Walker, Inc.
8910 Purdue Road, Suite 400 Indianapolis, IN 46268
(317) 735-3349
CS501
9 OF
SITE DETAILS
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100 Indianapolis, IN 46204
(317) 800-6388
M/E/P Engineers:
Apogee Consulting Group, PA 1511 Kildaire Farm Road, Suite 120 Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 CMB DSMRevisions: Date:
Structural Engineer:
Carl Walker, Inc.
8910 Purdue Road, Suite 400 Indianapolis, IN 46268
(317) 735-3349
10 OF
CS502
V
IN
D R
IV
E
0 4020
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100 Indianapolis, IN 46204
(317) 800-6388
M/E/P Engineers:
Apogee Consulting Group, PA 1511 Kildaire Farm Road, Suite 120 Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 CMB DSMRevisions: Date:
Structural Engineer:
Carl Walker, Inc.
8910 Purdue Road, Suite 400 Indianapolis, IN 46268
(317) 735-3349
GRADING PLAN
11 OF
CG101
V
IN
D R
IV
E
0 4020
N
UTILITY PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100 Indianapolis, IN 46204
(317) 800-6388
M/E/P Engineers:
Apogee Consulting Group, PA 1511 Kildaire Farm Road, Suite 120 Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 CMB DSMRevisions: Date:
Structural Engineer:
Carl Walker, Inc.
8910 Purdue Road, Suite 400 Indianapolis, IN 46268
(317) 735-3349
CU101
12 OF
UTILITY DETAILS
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100 Indianapolis, IN 46204
(317) 800-6388
M/E/P Engineers:
Apogee Consulting Group, PA 1511 Kildaire Farm Road, Suite 120 Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 CMB DSMRevisions: Date:
Structural Engineer:
Carl Walker, Inc.
8910 Purdue Road, Suite 400 Indianapolis, IN 46268
(317) 735-3349
MODEL 3620WQA12 SHOWN AS BASIS OF DESIGN. CONTRACTOR MAY SUBMIT ALTERNATE
PRODUCT FOR APPROVAL PROVIDED THAT PRODUCT MEETS THE MINIMUM PERFORMANCE
OF 80% TSS PARTICLE REMOVAL AT A TREATMENT FLOW OF 1.5 CFS.
CONTRACTOR MUST SUBMIT SHOP DRAWINGS PER SPECIFICATION 01 33 23 REGARDLESS
OF CHOSEN UNIT. SHEETS CS501 AND CS502 DO NOT CONSTITUTE SHOP DRAWINGS.
CU501
13 OF
UTILITY DETAILS
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100 Indianapolis, IN 46204
(317) 800-6388
M/E/P Engineers:
Apogee Consulting Group, PA 1511 Kildaire Farm Road, Suite 120 Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 CMB DSMRevisions: Date:
Structural Engineer:
Carl Walker, Inc.
8910 Purdue Road, Suite 400 Indianapolis, IN 46268
(317) 735-3349
CU502
14 OF
V
IN
D R
IV
E
0 4020
N
EROSION CONTROL PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100 Indianapolis, IN 46204
(317) 800-6388
M/E/P Engineers:
Apogee Consulting Group, PA 1511 Kildaire Farm Road, Suite 120 Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 CMB DSMRevisions: Date:
Structural Engineer:
Carl Walker, Inc.
8910 Purdue Road, Suite 400 Indianapolis, IN 46268
(317) 735-3349
CJ101
15 OF
EROSION CONTROL DETAILS
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100 Indianapolis, IN 46204
(317) 800-6388
M/E/P Engineers:
Apogee Consulting Group, PA 1511 Kildaire Farm Road, Suite 120 Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 CMB DSMRevisions: Date:
Structural Engineer:
Carl Walker, Inc.
8910 Purdue Road, Suite 400 Indianapolis, IN 46268
(317) 735-3349
CJ501
16 OF
V
IN
D R
IV
E
0 4020
N
SITE WAYFINDING PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100 Indianapolis, IN 46204
(317) 800-6388
M/E/P Engineers:
Apogee Consulting Group, PA 1511 Kildaire Farm Road, Suite 120 Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 CMB DSMRevisions: Date:
Structural Engineer:
Carl Walker, Inc.
8910 Purdue Road, Suite 400 Indianapolis, IN 46268
(317) 735-3349
8017 OF
CW101
SITE WAYFINDING DETAILS
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
NOT SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Guidon Design, Inc.
905 North Capitol Avenue, Suite 100 Indianapolis, IN 46204
(317) 800-6388
M/E/P Engineers:
Apogee Consulting Group, PA 1511 Kildaire Farm Road, Suite 120 Cary, NC 27511
(919) 858-7420
NEW PARKING GARAGE AT THE
CAPTAIN JAMES A. LOVELL
FEDERAL HEALTH CARE CENTER
NORTH CHICAGO, IL
556-305
1/9/2019 CMB DSMRevisions: Date:
Structural Engineer:
Carl Walker, Inc.
8910 Purdue Road, Suite 400 Indianapolis, IN 46268
(317) 735-3349
CW501
EMERGENCY
Main Hospital & Clinics
Building 123
Parking Garage/Valet Parking
Bourke Hall/Edu. Ctr.-Bldg. 4
Freedom Square-Bldg. 134
Building 131
Domiciliary-Bldgs. 7, 11, 66
Warehouse-Building 138
Buildings 1, 3, 5, 6, 9
Buildings 46, 48, 132
Buckley Rd. Exit
Parking Garage
Patient / Staff Lot
H Serves:
Buildings 133, 134, 135
Violators cited and towed at owner's expense
Patient / Staff Lot
H Serves:
Buildings 133, 134, 135
Violators cited and towed at owner's expense
Green Bay Rd. Exit
Green Bay Rd. Exit
Building 135
Bourke Hall/Edu. Ctr.-Bldg. 4
Building 131
Domiciliary-Bldgs. 7, 11, 66
Warehouse-Building 138
Buildings 1, 3, 5, 6, 9
Buildings 46, 48, 132
Buildings 46, 48, 132
Heroes Harbor
Kennedy Day Care Center
Building 135
Parking Garage
Green Bay Rd. Exit
18 OF
DIVISION 01 - GENERAL REQUIREMENTS
1.1 ALL DESIGN SHALL BE IN ACCORDANCE WITH THE FOLLOWING:
A. 2015 INTERNATIONAL BUILDING CODE
1.2 SPECIAL INSPECTIONS
A. THE CONTRACTOR, ON BEHALF OF THE VA, SHALL EMPLOY ONE OR MORE SPECIAL
INSPECTORS WHO SHALL PROVIDE INSPECTIONS AND MATERIALS TESTING DURING
CONSTRUCTION. ALL SPECIAL INSPECTIONS AND TESTING SHALL CONFORM TO THE
REQUIREMENTS OF SPEC 01 45 29, AND IBC 2015.
B. SPECIAL INSPECTIONS ARE IN ADDITION TO THE INSPECTIONS CONDUCTED BY THE BUILDING
OFFICIAL. SPECIAL INSPECTIONS SHALL NOT RELIEVE THE VA AND CONTRACTOR FROM
REQUESTING THE BUILDING OFFICIAL'S INSPECTIONS REQUIRED BY IBC SECTION 110.
C. SPECIAL INSPECTORS SHALL BE GIVEN PROPER NOTICE AND ACCESS TO THE SITE TO
PERFORM TESTING AND INSPECTION AS NECESSARY.
D. REQUIRED CATEGORIES OF SPECIAL INSPECTIONS:
1. STEEL CONSTRUCTION (IBC SECTION 1705.2)
HIGH STRENGTH BOLTING
COLD-FORMED STEEL DECK
2. CONCRETE CONSTRUCTION (IBC SECTION 1705.3)
CAST-IN-PLACE CONCRETE
REINFORCING STEEL
CAST-IN FABRICATED HARDWARE
POST-INSTALLED ANCHORS
PRECAST CONCRETE ERECTION
3. MASONRY CONSTRUCTION (IBC SECTION 1705.4)
4. SOILS (IBC SECTION 1705.6)
5. BARRIER CABLE INSTALLATION AND STRESSING
E. FAILURE TO PERFORM SPECIAL INSPECTIONS AND MATERIALS TESTING FOR THE INDICATED
CONSTRUCTION OR FAILURE TO CORRECT NON-CONFORMING WORK SHALL CONSTITUTE A
BASIS FOR REJECTION OF THE WORK AND ITS REMOVAL AND REPLACEMENT BY THE
CONTRACTOR AT NO ADDITIONAL COST TO THE VA, INCLUDING BUT NOT LIMITED TO:
1. COST OF REMOVAL AND REPLACEMENT OF ALL WORK FOR WHICH SPECIAL
INSPECTION/TESTING WAS REQUIRED BUT NOT PERFORMED, INCLUDING THE COST OF
SPECIAL INSPECTION/TESTING FOR THE REPLACEMENT WORK.
2. THE COST OF ALL RELATED WORK MADE NECESSARY BY THE REMOVAL AND
REPLACEMENT OF THE DEFICIENT WORK DESCRIBED IN ITEM 1 ABOVE.
3. THE COST FOR DESIGN PROFESSIONAL SERVICES RELATED TO ALL WORK IDENTIFIED IN
ITEMS 1 AND 2 ABOVE.
F. DUTIES AND RESPONSIBILITIES OF THE SPECIAL INSPECTOR:
1. THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED TO VERIFY THAT IT
CONFORMS TO THE CONTRACT DOCUMENTS.
2. THE SPECIAL INSPECTOR SHALL NOT AUTHORIZE OR APPROVE DEVIATIONS FROM THE
CONTRACT DOCUMENTS. ALL DEVIATIONS FROM THE CONTRACT DOCUMENTS MUST BE
INITIATED BY THE CONTRACTOR VIA A WRITTEN REQUEST FOR INFORMATION (RFI) AND
APPROVED BY THE ENGINEER OF RECORD PRIOR TO PROCEEDING WITH THE WORK.
3. THE SPECIAL INSPECTOR SHALL FURNISH WRITTEN INSPECTION REPORTS TO THE
ENGINEER OF RECORD. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE
ATTENTION OF THE CONTRACTOR FOR CORRECTION. IF CORRECTIONS ARE NOT MADE,
THE BUILDING OFFICIAL AND ENGINEER AND/OR ARCHITECT SHALL BE NOTIFIED.
4. UPON COMPLETION OF THE WORK, THE ENGINEER AND/OR ARCHITECT SHALL
COMPLETE AND SIGN THE APPROPRIATE FORMS CERTIFYING THAT, TO THE BEST OF
THEIR KNOWLEDGE, THE WORK IS IN CONFORMANCE WITH THE CONTRACT
DOCUMENTS, AND THE APPLICABLE PROVISIONS OF THE BUILDING CODE.
1.3 BUILDING CLASSIFICATION
A. IBC USE AND OCCUPANCY CLASSIFICATION:
LOW-HAZARD STORAGE, GROUP S-2
OPEN PARKING GARAGE
B. TYPE OF CONSTRUCTION IIB
C. UNPROTECTED, WITHOUT SPRINKLERS
D. AREA PER TIER 32,000 SQ. FT.
E. RAMP ACCESSIBLE TIERS 3
1.4 FIRE RESISTANCE
A. FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (IBC TABLE 601)
1. STRUCTURAL FRAME 0 HRS
2. BEARING WALLS:
i. EXTERIOR 0 HRS
ii. INTERIOR 0 HRS
3. NONBEARING WALLS AND PARTITIONS:
i. EXTERIOR 0 HRS
ii. INTERIOR 0 HRS
1.5 SERVICE LOADING AND DESIGN PARAMETERS - ASCE7-10 OR AS SPECIFIED HEREIN
A. RISK CATEGORY II
B. LIVE LOADING:
1. SUPPORTED PARKING AND DRIVE AREAS:
i. UNIFORM LOAD 40 PSF
ii. CONCENTRATED LOAD ACTING ON 20 SQ. IN. AREA 3,000 LBS
2. SLAB ON GRADE:
i. UNIFORM LOAD 100 PSF
ii. CONCENTRATED LOAD ACTING ON 20 SQ. IN. AREA 3,000 LBS
3. STAIRS AND EXITS:
i. UNIFORM LOAD 100 PSF
ii. CONCENTRATED LOAD ACTING ON 4 SQ. IN. AREA 300 LBS
4. HANDRAILS AND GUARDS:
i. UNIFORM LOAD 50 PLF
ii. CONCENTRATED LOAD 200 LBS
5. INTERMEDIATE RAILS, BALUSTERS, AND PANEL FILLERS:
i. CONCENTRATED LOAD ACTING ON 1 SQ. FT. AREA 50 LBS
6. VEHICLE BARRIER SYSTEMS
i. CONCENTRATED LOAD ACTING ON 1 SQ. FT. AREA
AT 18 OR 27 INCHES ABOVE FINISHED FLOOR 6,000 LBS
7. LIVE LOAD REDUCTION:
i. MAXIMUM LOAD REDUCTION FOR MEMBERS
SUPPORTING TWO OR MORE LEVELS 20 %
C. SNOW LOADING:
1. GROUND SNOW LOAD (Pg) 25.0 PSF
2. FLAT ROOF SNOW LOAD (Pf) 21.0 PSF
3. EXPOSURE FACTOR (Ce) 1.0
4. THERMAL FACTOR (Ct) 1.2
5. IMPORTANCE FACTOR (Is) 1.0
D. WIND LOADING:
1. BASIC WIND SPEED (V) 115 MPH
2. EXPOSURE CATEGORY B
4. INTERNAL PRESSURE COEFFICIENT (GCpi) +/- 0.18
5. COMPONENTS AND CLADDING DESIGN PRESSURES
i. ROOF - ZONE 1 NA -39.7 PSF
ii. ROOF - ZONE 2 NA -62.2 PSF
iii. ROOF - ZONE 3 NA -84.8 PSF
iv. WALL - ZONE 4 +27.1 -27.1 PSF
v. WALL - ZONE 5 +27.1 -49.7 PSF
E. SEISMIC LOADING:
1. IMPORTANCE FACTOR (Ie) 1.0
2. SPECTRAL RESPONSE ACCELERATIONS
i. SHORT PERIODS (SS) 0.115 %g
ii. 1 SEC PERIOD (S1) 0.056 %g
3. SITE CLASS C
4. DESIGN SPECTRAL RESPONSE ACCELERATIONS
i. SHORT PERIODS (SDS) 0.092 %g
ii. 1 SEC PERIOD (SD1) 0.063 %g
5. DESIGN CATEGORY A
6. SEISMIC BEHAVIOR:
i. NORTH/SOUTH DIRECTION:
ANALYSIS PROCEDURE:
EQUIVALENT LATERAL FORCE
SEISMIC FORCE RESISTING SYSTEM:
ORDINARY PRECAST SHEAR WALLS
BASE SHEAR (V) 365 KIPS
RESPONSE COEFFICIENT (Cs) 0.010
RESPONSE MODIFICATION FACTOR (R) 4
ii. EAST/WEST DIRECTION:
ANALYSIS PROCEDURE:
EQUIVALENT LATERAL FORCE
SEISMIC FORCE RESISTING SYSTEM:
ORDINARY PRECAST SHEAR WALLS
BASE SHEAR (V) 365 KIPS
RESPONSE COEFFICIENT (Cs) 0.010
RESPONSE MODIFICATION FACTOR (R) 4
F. VOLUMETRIC CHANGE LOADING - PCI MNL-120-10 (CHAPTER 4)
1. MAXIMUM SEASONAL CLIMATIC TEMPERATURE CHANGE 65 °F
2. ANNUAL AVERAGE AMBIENT RELATIVE HUMIDITY 74 %
1.6 FUTURE EXPANSION
A. THIS STRUCTURE IS DESIGNED FOR BOTH HORIZONTAL AND VERTICAL EXPANSION. THE
STRUCTURE IS DESIGNED FOR VERTICAL EXPANSION TO 6 FULL PARKING LEVELS AND A
PARTIAL 7TH LEVEL. ALSO, THE CURRENT 2-BAY GARAGE IS DESIGNED TO BE A 3-BAY GARAGE
BY ADDING AN ADDITIONAL PARKING BAY ON THE SOUTH.
1.7 MINIMUM HEADROOM CLEARANCE
A. SIGNED CLEARANCE:
1. ALL LEVELS 8'-2"
B. MINIMUM STRUCTURAL CLEARANCE:
2. ALL LEVELS 8'-4"
1.8 DRAINAGE
A. PROVIDE AS INDICATED BY PLAN ELEVATIONS WITH 1 1/2% MINIMUM SLOPE ON
PARKING SURFACES WHERE ELEVATIONS NOT INDICATED
1.9 DATUM
A. ALL STRUCTURAL ELEVATIONS ARE REFERENCED FROM MEAN SEA LEVEL (MSL) UNLESS
NOTED OTHERWISE
1.10 CORROSION PROTECTION SYSTEM
A. CORROSION PROTECTION SYSTEM IS BASED ON CRITERIA PRESENTED IN ACI 362.1R "GUIDE
FOR THE DESIGN AND CONSTRUCTION OF DURABLE CONCRETE PARKING STRUCTURES" FOR
ZONE III EXPOSURE
1. PRECAST, FIELD-TOPPED STRUCTURE WITH CONCRETE SEALER, CORROSION INHIBITOR,
EPOXY COATED REINFORCEMENT, LOW PERMEABILITY, AND SPECIAL COVER
REQUIREMENTS AS SPECIFIED HEREIN
2. CONCRETE ACCESSORIES TO BE HOT-DIP GALVANIZED AND/OR STAINLESS STEEL AS
SPECIFIED HEREIN
1.11 CONSTRUCTION NOTES
A. GENERAL
1. WHERE DIMENSIONS ARE INDICATED FOR EXISTING STRUCTURES, THEY ARE
APPROXIMATE AND FOR REFERENCE ONLY. CONTRACTOR SHALL VERIFY IN FIELD (VIF)
ALL DIMENSIONS AND ELEVATIONS PRIOR TO CONSTRUCTION. ANY VARIATIONS
BETWEEN EXISTING DIMENSIONS AND/OR ELEVATIONS ON DRAWINGS SHALL BE
REPORTED TO ENGINEER.
2. ALL OMISSIONS OR CONFLICTS AMONG VARIOUS ELEMENTS OF DRAWINGS AND/OR
SPECIFICATIONS SHALL BE REPORTED TO ENGINEER BEFORE PROCEEDING WITH ANY
WORK.
3. VERIFY AND COORDINATE LOCATION AND SIZE OF ALL OPENINGS AND SLEEVES
THROUGH FLOORS, WALLS, AND ROOFS WITH RESPECTIVE SUBCONTRACTOR
(MECHANICAL, ELECTRICAL, HVAC, ETC.)
4. VERIFY STRUCTURAL ELEVATIONS AND DIMENSIONS WITH RESPECTIVE OTHER TRADES
AND DRAWINGS.
5. VERIFY LOCATION OF SLAB DEPRESSIONS, FLOOR DRAINS, INSERTS, AND OTHER
RELATED ITEMS.
6. NO STRUCTURAL MEMBERS SHALL BE CUT OR PENETRATED FOR PIPES, DUCTS,
CONDUITS, ETC., UNLESS SPECIFICALLY DETAILED OR APPROVED IN WRITING BY
ENGINEER.
7. FIELD VERIFY THE LOCATIONS OF EXISTING STRUCTURES, UTILITIES, ETC., AND NOTIFY
ENGINEER OF INTERFERENCES NOT NOTED ON DRAWINGS.
8. FLOOR SLAB ELEVATIONS INDICATED ON DRAWINGS ARE ESTABLISHED TO PROVIDE
POSITIVE DRAINAGE AND PROVIDE REQUIRED HEADROOM CLEARANCE, REFER TO
SECTIONS 1.7 AND 1.8. NOTIFY ENGINEER OF GRADES INDICATED WHICH DO NOT ALLOW
FOR MINIMUM HEADROOM CLEARANCE.
DIVISION 02 - EXISTING CONDITIONS
DIVISION 03 - CONCRETE
3.1 ALL DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE FOLLOWING:
A. ACI 318-14
B. ACI 362.1R-12
C. REFER TO SPECIFICATION SECTION 033000 FOR INFORMATION NOT LISTED HEREIN
3.2 CONCRETE
DESCRIPTION F'C (PSI)
MAXIMUM
CHLORIDE ION
MAX W/C
RATIO
AVERAGE
ENTRAINED AIR
FOOTINGS 4000 STD 0.30 0.50 N/A
WALLS 5000 CNA/SPA 0.15 0.40 6-1/2%
SLAB-ON-GRADE 4500 STD/SF 0.15 0.40 6-1/2%
TOPPING SLAB 5000 CNA/SPA 0.15 0.40 6-1/2%
ISLANDS & PADS 4000 STD/F 0.15 0.40 6-1/2%
ALL OTHERS 4000 STD 0.30 0.40 6-1/2%
NOTES:
(1) STD: DESIGNATES A CONCRETE MIX DESIGN IN ACCORDANCE WITH SPECIFICATION SECTION
033000 WHICH DOES NOT REQUIRE SILICA FUME, GGBS/FLY ASH, OR CALCIUM NITRITE
ADMIXTURE
(2) CNA: DESIGNATES A CONCRETE MIX DESIGN IN ACCORDANCE WITH SPECIFICATION SECTION
033000 WHICH CONTAINS 3 GAL/CY OF CALCIUM NITRITE CORROSION-INHIBITOR ADMIXTURE
(3) SPA: DESIGNATES A CONCRETE MIX DESIGN IN ACCORDANCE WITH SPECIFICATION SECTION
033000 WHICH CONTAINS 20% MINIMUM FLY ASH BY WEIGHT OF CEMENT.
(4) SF: DESIGNATES A CONCRETE MIX DESIGN IN ACCORDANCE WITH SPECIFICATION SECTION
033000 WHICH CONTAINS 4-1/2 LBS/CY OF STRUCTURAL MACRO FIBERS
(5) F: DESIGNATES A CONCRETE MIX DESIGN IN ACCORDANCE WITH SPECIFICATION SECTION
033000 WHICH CONTAINS 1-1/2 LBS/CY OF FIBRILLATED FIBER REINFORCEMENT OR 1 LBS/CY
MICROFILAMENT REINFORCEMENT
(6) ALL NORMALWEIGHT CONCRETE SHALL HAVE A DENSITY OF APPROXIMATELY 145 PCF UNLESS
NOTED OTHERWISE
(7) AVERAGE AIR-ENTRAINED VALUES ARE FOR IN-PLACE CONCRETE. TOLERANCE ON TOTAL AIR
CONTENT IS 1-1/2% PER ACI 318.
(8) ALL AIR-ENTRAINED CONCRETE SHALL INCLUDE 564 LBS/CY MINIMUM OF CEMENT. THE
WEIGHT OF SILICA FUME, GGBS, AND FLY ASH MAY BE INCLUDED WITH THE WEIGHT OF
CEMENT.
3.3 CEMENT
A. ASTM C 150 TYPE I OR III
3.4 AGGREGATES
A. ASTM C 33
3.5 MILD REINFORCEMENT
A. MILD REINFORCEMENT, ASTM A 615 GRADE 60
B. MILD REINFORCEMENT (LOW ALLOY WELDABLE), ASTM A 706 GRADE 60
C. MECHANICAL TENSION AND COMPRESSION SPLICES AS INDICATED ON DRAWINGS
D. MECHANICAL TERMINATION SIZES AS INDICATED ON DRAWINGS
E. EPOXY COATING FOR PLAIN AND DEFORMED MILD REINFORCEMENT, ASTM A 775
F. WELDED PLAIN WIRE FABRIC SHEETS, ASTM A 185 GRADE 65
G. EPOXY COATING FOR PLAIN WELDED WIRE FABRIC, ASTM A 884
H. EPOXY COATING FOR DOWEL BARS SHALL BE THE SAME AS SPECIFIED FOR REINFORCEMENT
TO BE SPLICED
I. WELDING FOR REINFORCING STEEL, AWS D1.4
J. CONCRETE PROTECTION SHALL BE PER ACI 362.1R, EXCEPT AS NOTED ON DRAWINGS AND
SPECIFIED HEREIN. SPECIFIC DRAWINGS AND DETAILS MAY OR MAY NOT INDICATE EPOXY
COATING OR UNCOATED REINFORCING. IN AREAS OF DISPUTE, THIS SCHEDULE SHALL
GOVERN IN ALL CASES.
DESCRIPTION COVER PROTECTION
FOOTINGS 3" UNCOATED
WALLS IN CONTACT WITH EARTH 2" UNCOATED
WALLS NOT IN CONTACT WITH EARTH 1-1/2" UNCOATED
FLOOR TOPPING 1-1/2" EPOXY COATED
SLAB-ON GRADE REINFORCING 2" FROM TOP UNCOATED
ISLANDS, HK PADS, CURBS, MISC. 1-1/2" EPOXY COATED
BACK-UP BARS, SUPPORT BARS, ETC. N/A EPOXY COATED
3.6 POST-INSTALLED MILD REINFORCEMENT
A. POST-INSTALLED REINFORCING BAR CONNECTIONS SHALL BE DESIGNED PER THE ACI 318
BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE. POST-INSTALLED
REINFORCING BAR CONNECTIONS SHALL CONSIST OF THE FOLLOWING ADHESIVE SYSTEMS AS
PROVIDED BY HILTI, INC. (OR APPROVED EQUAL). CONTACT HILTI AT (800) 879-8000 FOR
PRODUCT RELATED QUESTIONS.
B. POST-INSTALLED REINFORCING BAR CONNECTIONS IN CONCRETE
1. EPOXY SYSTEMS WITH SAFESET TECHNOLOGY:
i. HILTI HIT-RE 500 V3 SAFESET SYSTEM WITH HILTI HOLLOW DRILL BIT (TE-CD OR
TE-YD), AND HILTI VC 20/40 VACUUM (VC 20-U OR VC 40-U) WITH POST-INSTALLED
STEEL REINFORCING BARS INSTALLED PER ICC ESR-3814
ii. HILTI HIT-HY 200 SAFESET SYSTEM WITH HILTI HOLLOW DRILL BIT (TE-CD OR
TE-YD), AND HILTI VC 20/40 VACUUM (VC 20-U OR VC 40-U) WITH POST-INSTALLED
STEEL REINFORCING BARS INSTALLED PER ICC ESR-3817
C. THE DESIGN OF STRAIGHT POST-INSTALLED REINFORCING BARS SHALL BE PERFORMED PER
THE DEVELOPMENT AND SPLICE LENGTH REQUIREMENTS OF THE ACI 318 BUILDING CODE
REQUIREMENTS FOR STRUCTURAL CONCRETE. THE POST-INSTALLED REINFORCING BAR
SYSTEM IS AN ALTERNATIVE TO CAST-IN-PLACE REINFORCING BARS GOVERENED BY ACI 318
AND IBC CHAPTER 19.
D. THE EPOXY SYSTEM SHALL BE TESTED IN ACCORDANCE WITH THE ICC-ES ACCEPTANCE
CRITERIA FOR POST-INSTALLED EPOXY ANCHORS IN CONCRETE ELEMENTS (AC308), TABLE 3.8.
TECHNICAL DATA SHALL BE PUBLISHED IN AN ICC-ES EVALUATION SERVICE REPORT SHOWING
COMPLIANCE WITH IBC.
1. ICC-ES ESR-3814 FOR HILTI HIT-RE 500 V3 EPOXY ANCHORS AND POST-INSTALLED
REINFORCING BAR CONNECTIONS IN CRACKED AND UNCRACKED CONCRETE.
2. ICC-ES ESR-3187 FOR HILTI HIT-HY 200 EPOXY ANCHORS AND POST-INSTALLED
REINFORCING BAR CONNECTIONS IN CRACKED AND UNCRACKED CONCRETE.
E. POST-INSTALLED REINFORCING BAR INSTALLATION…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.