521-B72027_-_XR_RF,_VAMC_BIRMINGHAM,_AL_redacted.pdf

PDF 84 KB Posted

Attached to
SEPTEMBER 2018 CONSOLIDATION
Solicitation number
36A79719Q0002
Issued by

About this file

36A79719Q0002 0002 521-B72027 - XR RF, VAMC BIRMINGHAM, AL redacted.pdf

View the file

Other files

File Type Posted
589_B82017revised.pdf PDF
589-B80016___VISN_15_KCVA_Medical_Center,_589-B80016revised.xlsx XLSX spreadsheet
36A79719Q0002_0004.docx DOCX document
589-B80016revised.pdf PDF
589-B82017___VISN_15_Eastern_Kansas_VAMC_Topeka_Campus,_589_B82017revised.xlsx XLSX spreadsheet
SEP_FY18_Consolidation_List_Amend_0004.xlsx XLSX spreadsheet
AMENDMENT_0003_-_Continuation_page.pdf PDF
Sept_18_Consolidation_Schedule_-_Revised_12122018.pdf PDF
36A79719Q0002_0003.docx DOCX document
537-B82059_-_XR_PORT_RAD,_VAMC_CHICAGO,_IL_Redacted.pdf PDF
549-B80428_-_XR_US,_VAMC_DALLAS,_TX_redacted.pdf PDF
36A79719Q0002_0002.docx DOCX document
523-B81008_B81009_B81010___VISN1_VA_Boston_Healthcare_System-_West_Roxbury_Campus,_523-B81008B81009B81010revisedafterquestions.xlsx XLSX spreadsheet
668-B80015revised_V2.pdf PDF
608-B83003revisedafterquestions.pdf PDF
523-B81008B81009B81010revisedafterquestions.pdf PDF
689-B81009___VISN_1_VA_Connecticut_Healthcare_System,_689-B81009revisedafterquestions.xlsx XLSX spreadsheet
608-B83003___Manchester_VA_Medical_Center,_608-B83003revisedafterquestions.xlsx XLSX spreadsheet
AMENDMENT_0002_-_Continuation_page.pdf PDF
612-B86025_-_XR_US_VAMC_MARTINEZ_CA_redacted.pdf PDF
537-B82069_-_XR_US,_VAMC_CHICAGO,_IL_redacted.pdf PDF
689-B81009revisedafterquestions.pdf PDF
636-B84043_-_Specifications_Radiology_Ultrasound_-_Iowa_City_-_REVISED.pdf PDF
668-B80015___20_Mann-Grandstaff_VA_,_668-B80015revised_V2.xlsx XLSX spreadsheet
SEP_FY18_Consolidation_List_Amend_0002.xlsx XLSX spreadsheet
36A79719Q0002-0001014.pdf PDF
36A79719Q0002-0001015.pdf PDF
36A79719Q0002-0001035.zip ZIP file
36A79719Q0002-0001013.pdf PDF
36A79719Q0002-0001012.docx DOCX document
36A79719Q0002-0001020.zip ZIP file
36A79719Q0002-0001017.pdf PDF
36A79719Q0002-0001021.zip ZIP file
36A79719Q0002-0001016.pdf PDF
36A79719Q0002-0001019.zip ZIP file
36A79719Q0002-0001026.zip ZIP file
36A79719Q0002-0001031.zip ZIP file
36A79719Q0002-0001022.zip ZIP file
36A79719Q0002-0001036.pdf PDF
36A79719Q0002-0001032.zip ZIP file
36A79719Q0002-0001023.zip ZIP file
36A79719Q0002-0001018.zip ZIP file
36A79719Q0002-0001028.zip ZIP file
36A79719Q0002-0001037.xlsx XLSX spreadsheet
36A79719Q0002-0001033.zip ZIP file
36A79719Q0002-0001024.zip ZIP file
36A79719Q0002-0001025.zip ZIP file
36A79719Q0002-0001029.zip ZIP file
36A79719Q0002-0001027.zip ZIP file
36A79719Q0002-0001034.pdf PDF
Show 40 more

Latest 50 of 141 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 65KW HIGH FREQUENCY RADIOGRAPHIC /

FLUOROSCOPIC X-RAY GENERATOR - NEW

• kV Radiographic 40-125 kV

• mA Radiographic 10-800 mA

• kV Fluoroscopic 40-125 kV

• Pulsed Fluoro mA 16-80 mA

• Pulsed Fluoro Rate 3, 6, 12.5 p/s

• Spot Film Rate Up to 6 Spot Images / Second

• Single Tube Operation

• Source to Patient Dose Compensation

• Programmable Patient Entrance Dose Rate

• AEC/ABS

• 400 or 480 VAC, 3 Phase

• Dual Speed Starter

• Digital Interface

1 TABLESIDE SYSTEM CONTROLS - NEW

• Controls both 'C' Arm and Table Motions

• Mounted on mobile stand (1020-0154) for convenient tableside positioning

1 THREE (3) FUNCTION FOOT SWITCH - NEW

1 PRINCESTAR HIGH RESOLUTION FLAT PANEL DETECTOR

SYSTEM WITH VARIAN 3030 + 30 CM X 30 CM PLAT PANEL

DETECTOR - NEW

ammhinhausec Typewritten Text

XR C-ARM, VAMC BIRMINGHAM, AL

PO# 521-B72027

QTY P/N DESCRIPTION UNIT PRICE TOTAL PRICE

1 RAYSTAR-200-OMI HIGH RESOLUTION IMAGE

PROCESSOR - NEW

• Modes of Operation: Fluoro, Fluoro Loop, CINE

• Auto Calibration

• Image Storage Capacity: 80,000 minimum

• Auto Loop Replay

• Last Image Hold

• Real-Time 5 Level Edge Enhancement

• Image Auto Window/Level

• Motion Correction with Programmable Thresholds

• Zoom / Pan / Window / Level Adjustments

• Digital Shutters

• Measurement Package - Length, Angle, Calibration, Annotation, Pointer

• Multi-Image Display: 4 on 1

• Dynamic Replay of Loops: 4 on 1

• DICOM 3.0 Network Interface

• DICOM CD/DVD Recording with Embedded Viewer

• JPEG/AVI Image Save to CD/DVD or USB

• Windows Print

4 19" FLAT PANEL DISPLAY- NEW

1 OMI FLAT PANEL RADIATION SHIELD FOR FLAT PANEL

DETECTORS - NEW

1 OMI TABLE RADIATION SHIELD

1 SQUARE FIELD COLLIMATOR - NEW

• Fixed mount, zero rotation

• Automatically collimates to selected field size

• Automatically tracks SID

1 MGT HIGH SPEED DUAL FOCUS X-RAY TUBE W/ FAST

COOLING ANODE - NEW

• 1,000,000 Heat Unit Anode

• 12° target, 270° horns

• Rated 40/100 kW

• 0.6 - 1.2 f/s

1 QUIET STYLE HEAT EXCHANGER- NEW

• Reduces X-Ray tube heat by 100,000 heat units per minute

1 SET OF SYSTEM INTERCONNECTING CABLES- NEW

1 PAIR OF LOW NOISE HIGH VOLTAGE CABLES - 65 FEET-

NEW

1 I-111FP ELECTRONIC RACK CABINET (May include grean leaf components)

1 CPU ELECTRONICS ENCLOSURE - NEW

1 INTEGRATED FLUOROSCOPIC DOSE READOUT SYSTEM -

NEW

• Displays accumulated patient entrance dose per study

• Displays accumulated fluoroscopic exposure time per study

• Displays patient's entrance dose rate

1 82" TABLE PAD - NEW

1 ANTI-FATIGUE FLOOR MAT, 3' X 5' - NEW

QTY P/N DESCRIPTION UNIT PRICE TOTAL PRICE

1 INSTALL ONSITE INSTALL AND TURN OVER