26NEA0277LBP-GA101.pdf

PDF 238 KB Posted

Attached to
Lakeland Electric - Unit 5 - 2026 Fall Outage Contract Services
Solicitation number
2026-RFP-114
Issued by
Polk County, Florida

About this file

This is a technical engineering drawing prepared by Nooter/Eriksen Inc. for the City of Lakeland's McIntosh Unit #5 Combined Cycle power generation facility located in Lakeland, Florida. The drawing details a desuperheater spool replacement component for a steam line system (RP-03) designed to operate at 1,005°F and 610 PSIG in compliance with ASME Code Section 1. The component specifications include a 16-inch Schedule 20 pipe with a 6-inch insulation thickness, featuring various pressure-rated flanges (CL2500, CL1500, CL3000), welded connections, and spray water nozzles. The drawing was released on September 1, 2026, and includes detailed section views, material specifications (SA-182-F22, SA-387-22, SA-182-P22), weld symbols per AWS A2.4, and fabrication dimensions to guide construction and installation of the replacement spool between Reheater #1 and Reheater #2.

This technical drawing supports the City of Lakeland's November 29 through December 19, 2026 Unit No. 5 Fall Outage contract solicitation, which seeks qualified boiler and HRSG contractors capable of performing code welds on thin-wall HRSG tubes and heavy wall P91 piping. The solicitation is structured as a Request for Proposal requiring bidders to demonstrate measurable and verifiable experience and qualifications as industrial boiler contractors. The drawing serves as a project specification document that outlines the scope of work and technical requirements for one of the components to be replaced or serviced during the scheduled outage period.

View the file

Other files

File Type Posted
Lakeland_Electric_-_Unit_5_-_2026_Fall_Outage_Contract_Services_(Addendum_#2_Revision).pdf PDF
Sample_Standard_Contract_Form.pdf PDF
25-1300-4002_-_HRSG_General_Arrangement_Right_side.pdf PDF
COL_Purchase_Order_Ts&Cs.pdf PDF
25-1301-4004.pdf PDF
Packing_Gland_for_8"_Nozzle.pdf PDF
25-1301-4001.pdf PDF
Bundle_Layout_Elevation_View_Color.pdf PDF
25-1301-4006.pdf PDF
Packing_Gland_for_6"_Nozzle.pdf PDF
25-1300-4003_-_HRSG_General_Arrangement_Left_Side.pdf PDF
25-1301-4014.pdf PDF
25-1317-5021_Interconnecting_Piping_RP-03_Reheater_#1_to_Reheater_#2.pdf PDF
25-1301-4011.pdf PDF
25-1301-4012.pdf PDF
New_Map_of_HRSG_-_Doors.pdf PDF
25-1301-4017.pdf PDF
25-1317-5022_Interconnecting_Piping_RP-03_Reheater_#1_to_Reheater_#2.pdf PDF
Pipe_Spec_T3_Drain.pdf PDF
Final_2026_City_of_Lakeland_Standard_Contract_Form.pdf PDF
25-1301-4002.pdf PDF
Pipe_Spec_EG11S_-_All_3_Valves.pdf PDF
Pipe_Spec_T1_Drain_Valve.pdf PDF
Pipe_Spec_T2_Drain_Valve.pdf PDF
25-1300-4064_NE_Plan_View.pdf PDF
HP_SH_Desuperheater_Spool_GA.pdf PDF
25-1300-4006_NE_HRSG_Plan_View.pdf PDF
Packing_Gland_for_10"_Nozzle.pdf PDF
Reheater_Interconnecting_Piping.pdf PDF
25-1300-4005_NE_HRSG_Elevation_View_Right_Side.pdf PDF
PSM_-_Contractor_Audit_Form.pdf PDF
Indemnification_2026_Contractor_-_FDOT.docx DOCX document
Indemnification_2026_Vendor.doc DOC document
Indemnification_2026_Consultant_-_FDOT.docx DOCX document
Human_Trafficking_Affidavit.docx DOCX document
Indemnification_2026_Consultant.doc DOC document
Indemnification_2026_Contractor.doc DOC document
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RJL

1-SEPT-2026

RJL JMD0

CORR. ALLOW.: 0"

INSUL THK: 6"

DESIGN TEMP: 1005°F

DESIGN PRESS: 610 PSIG

CODE: ASME CODE SECT 1 BP

SERVICE: STEAM

LINE NO.: RP-03

DESIGN CONDITIONS:

SPOOL REPLACEMENT GENERAL ARRANGEMENT

REHEATER #1 TO REHEATER #2 DESUPERHEATER

2'-6•"

1'-6•"1'-0"

6"

9"4•" 3" 3"3'-0"3"

6'-0" DESUPERHEATER LINER1'-6•"

8'-11•" DESUPERHEATER SPOOL OVERALL

SEE SECTION VIEWS FOR ACTUAL CONNECTION ORIENTATION

1…" DIA. HOLE

R E

F

R E

F

(SA-182-F22)

3" CL2500 (RFLWN)

(TYP UNLESS NOTED)

(SA-182-F22)

2" CL1500 (RFLWN)

3" DIA. HOLE (PIPE)

3‚" DIA. HOLE (LINER)

(SA-182-F22)

1" CL3000 COUPLET

(SA-182-F22)

1" CL3000 SOCKOLET

1ˆ" DIA. HOLE IN LINER (TYP)

DRILL 1•" DIA. HOLE IN PIPE AND

SAME, OR COMPATIBLE MATERIAL AS PIPE

1" DIA. x 2†" LG. ROD

2" DIA. HOLE

(SA-182-P22)

18" SCH. 80 PIPE

(TYP)

STRADDLE CENTERLINE

BOLT HOLES TO

TO BE IN DIRECTION OF FLOW

DESUPERHEATER SPRAYWATEWR NOZZLE

FLOW

8" ƒ

ˆ

L A

N D

T H

K

TYPICAL PIPE END PREP

A B

A B

SECTION A-A

SECTION B-B

(SA-387-22) WELD TO LINER ONLY

(3) EQUALLY SPACED AT (3) PLACES

„" SQUARE x 3" LG. SPACER

0°

90°

180°

270°

0°

270°90°

180°

1" SOCKOLET

1" COUPLET

2" CL1500 LWN

FLANGE

EXISTING BLIND

ON CENTERLINE

PINS TO BE

AT (3) PLACES

EQUALLY SPACED

(3) ROD SPACERS

DESUPERHEATER

EXISTING

3" CL2500 LWN

CJP

3/8

TYP

TO LINER

TYP ROD1/8

1/8

3/8 TO PIPE

TYP AT PIN

3/8

26NEA0277LBP-GA101

(SA 182-P22)

(MACHINED TO 1'-3‡" O.D.)

16" SCH. 20 PIPE

JMD

INITIAL RELEASE

WELD SYMBOLS ARE PER AWS A2.4 LATEST EDITION

PROJECT:

JOB NO SHEET REV FE-RELEASE DATE:

CODE

COMP

CODE

DOC

REVISIONREV CHKDWN

DWN

PM

SE

CHK

PE

TE

ORIG. JOB NO:

1 2 3 4 5 6 7 8 9 10 11 12

B

C

D

E

F

G

A

WAY APPLIES TO DESIGN AND FEATURES WHICH ARE OUR CUSTOMER'S PROPERTY.

AND MUST NOT BE COPIED OR REPRODUCED WITHOUT PERMISSION. THE FOREGOING IN NO

HOW, AND ALL NEW OR PATENTABLE FEATURES ARE THE PROPERTY OF NOOTER/ERIKSEN INC.

THIS DRAWING HAS BEEN FURNISHED BY NOOTER/ERIKSEN INC.: THE INFORMATION KNOW

LAKELAND 997000

LOCATION: LAKELAND, FL

PROJECT: MCINTOSH #5 COMBINED CYCLE

PURCHASER: CITY OF LAKELAND

26NEA0277.dgn 26NEA0277LBP-GA101 9/1/2026 12:46:46 PM

File details come from the government source that posted it. Updated .