About this file

This is a Performance Standards exhibit document prepared by Collier County's Public Utilities Department in Florida, establishing mandatory reliability engineering criteria for biosolids hauling and related public utility operations. The five key performance standards (5Ns) require contractors to maintain zero offsite odors, zero sanitary sewer overflows or spills (both onsite and offsite), zero offsite fugitive dust emissions, mitigated offsite noise prior to facility fence lines, and mitigated offsite light emissions prior to fence lines, all on a 24/7/365 basis. These standards apply to water plants, wastewater plants, pump stations, solid waste sanitary landfills, transfer stations, and other public utilities infrastructure. Any deviations from these criteria require advance review and recommendation by both the Engineering and Operations Division Directors, with final approval authority resting with the Department Head.

These performance standards are mandatory contractual requirements that all proposers responding to RFP 25-8403R for biosolids hauling services must comply with in their proposals and throughout contract execution. The standards represent non-negotiable operational expectations that contractors must meet regardless of facility location or service type, whether providing services at North County Water Reclamation Facility, South County Water Reclamation Facility, Golden Gate Wastewater Treatment Plant, Orange Tree Wastewater Treatment Plant, or Northeast Service Area Interim Wastewater Treatment Plant. Compliance with these standards is a prerequisite for contract award and continued performance under the initial five-year term plus three optional five-year renewal periods.

View the file

Other files

File Type Posted
OkeechobeeFirstAmendmentFE_.pdf PDF
PB_Renewal.pdf PDF
PB_Synagro_Addendum_FE.pdf PDF
25-8403R_Attachment_B_-Cost_of_Services_02-18-26.xlsx XLSX spreadsheet
25-8403R_FPP_FEMA_97.036_12.25.pdf PDF
Form_2_Conflict_of_Interest_Certification.pdf PDF
Form_4_Reference_Questionnaire.pdf PDF
25-8403R_Attachment_A_-_Category_Interest.pdf PDF
25-8403R_Attachment_B_-Cost_of_Services_02-18-26.xlsx XLSX spreadsheet
25-8403R_Insurance_Requirements.pdf PDF
Form_1_Vendor_Declaration_Statement.pdf PDF
Form_2_Conflict_of_Interest_Certification.pdf PDF
Form_4_Reference_Questionnaire.pdf PDF
PO_Terms_and_Conditions_Rev.3.pdf PDF
Request_for_Proposals_Instructions_Version_2.pdf PDF
25-8403R_Exhibit_C_-_GENERAL_PUD_PERFORMANCE_STANDARDS.pdf PDF
25-8403R_Insurance_Requirements.pdf PDF
Form_3_Immigration_Certification.pdf PDF
PO_Terms_and_Conditions_Rev.3.pdf PDF
25-8403R_Insurance_Requirements.pdf PDF
25-8403R_Solicitation_.pdf PDF
Checklist_-Vendor_Checklist.pdf PDF
Form_1_Vendor_Declaration_Statement.pdf PDF
Form_4_Reference_Questionnaire.pdf PDF
Request_for_Proposals_Instructions_Version_2.pdf PDF
25-8403R_Authorization_to_Advertise.pdf PDF
25-8403R_Exhibit_B-2_-_Golden_Gate_Orange_Tree_Analysis.pdf PDF
25-8403R_Exhibit_C_-_GENERAL_PUD_PERFORMANCE_STANDARDS.pdf PDF
25-8403R_Insurance_Requirements.pdf PDF
Form_3_Immigration_Certification.pdf PDF
Request_for_Proposals_Instructions_Version_2.pdf PDF
25-8403R_Exhibit_B-1_-_NCWRF_SCWRF_Analysis.pdf PDF
25-8403R_Exhibit_B-2_-_Golden_Gate_Orange_Tree_Analysis.pdf PDF
25-8403R_Solicitation_.pdf PDF
Form_3_Immigration_Certification.pdf PDF
Form_5_Grant_Provisions.pdf PDF
25-8403R_Exhibit_B-1_-_NCWRF_SCWRF_Analysis.pdf PDF
25-8403R_Exhibit_B-2_-_Golden_Gate_Orange_Tree_Analysis.pdf PDF
Form_5_Grant_Provisions.pdf PDF
Request_for_Proposals_Instructions_Version_2.pdf PDF
25-8403R_Attachment_A_-_Category_Interest.pdf PDF
25-8403R_Exhibit_A_-_Plant_Details_Production_Rates.pdf PDF
25-8403R_Exhibit_B-1_-_NCWRF_SCWRF_Analysis.pdf PDF
25-8403R_Exhibit_B-2_-_Golden_Gate_Orange_Tree_Analysis.pdf PDF
25-8403R_FPP_FEMA_97.036_12.25.pdf PDF
Fixed_Term_Service_Multi-Contractor_Award_Agreement_[2026__ver.1].pdf PDF
Form_2_Conflict_of_Interest_Certification.pdf PDF
Form_5_Grant_Provisions.pdf PDF
25-8403R_Attachment_A_-_Category_Interest.pdf PDF
25-8403R_Exhibit_A_-_Plant_Details_Production_Rates.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

The following 5Ns are the PUD Performance Criteria that needs to be considered and included in

• solicitations,

• agreements,

• contracts, that are specifically related to our Water Plants, Wastewater Plants, Master Pump Stations, Community Pump Stations R&Rs, Solid Waste Sanitary Landfills, Transfer Stations, among others

PUBLIC UTILITIES

5N-RELIABILITY ENGINEERING CRITERIA

No offsite odors | 24/7/365

No SSOs-Spills offsite/onsite | 24/7/365

No offsite fugitive-dust emissions | 24/7/365

No offsite Noise | To be mitigated prior to fence line per Code | 24/7/365

No offsite Light emissions | To be mitigated prior to fence line per Code

Any deviation to above 5N-Reliability Engineering Criteria and guidance has to be reviewed and recommended by both Engineering and Operations Division Directors in advance for approval by the Department Head.