2-2026-03-03 - Climbers Run - Structural BID SET.pdf
PDF 2 MB Posted
- Solicitation number
- Not on record
- Issued by
- Lancaster County, Pennsylvania
About this file
This document comprises structural design specifications and engineering drawings prepared by Durst & Taylor Structural Engineering, LLC for the Climbers Run Nature Center site improvements project in Pequea, Pennsylvania. The project, administered by the Lancaster County Conservancy, involves the construction of proposed timber walkways and foundations, including an eastern walkway to a pond and a dock structure with ADA-accessible features. The design incorporates multiple timber deck systems supported by helical piles, concrete retaining walls for grades of 4 feet or less, and wooden curbs with guardrails. The structural components include pressure-treated Southern pine lumber (No. 2 or better) with black locust decking, various beam and joist configurations ranging from 4x8 to 8x14 dimensions, and stainless steel hardware for corrosion resistance. Sealed bids for the overall site improvements project were due May 19, 2026, with the successful bidder required to furnish performance and payment bonds equal to 100 percent of the contract price. The project is partially funded through a Pennsylvania Department of Conservation and Natural Resources (DCNR) grant and is subject to Pennsylvania Prevailing Wage Act requirements.
The structural design adheres to the 2021 International Building Code with specific design parameters including a 3,000 PSF allowable soil bearing capacity, 100 PSF floor live load, 30 PSF ground snow load, and 115 MPH basic wind speed. All lumber must be treated for UC4B use category per AWPA standards with maximum 19 percent moisture content. Helical piles are designed by the supplier's engineer to support varying loads, with middle piles designed for 2,000 pounds dead load and 8,000 pounds live load, while other piles support 1,000 pounds dead load and 4,000 pounds live load with 2,500 pounds net uplift capacity. Special inspections are required for soil conditions, excavation depths, and controlled fill placement per Section 1704 of the 2018 International Building Code. The contractor bears responsibility for all temporary bracing, shoring, scaffolding, construction sequencing, and adherence to local codes and OSHA safety requirements. Shop drawings must be reviewed and approved by the engineer before work commences, and all foundation construction must comply with specific backfill compaction requirements of 95 percent maximum dry weight density per ASTM D1557.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NOT TO SCALE
WALLS RETAINING 4'-0" OR LESS
RETAINING WALL SECTION FOR
(REFER TO CIVIL PLANS FOR LOCATIONS)
3'-4"
1'-4" 1'-0" 1'-
0"
4'- 0"
MA
X.
2'- 0"
MA
X.
1'-0"
3'- 0"
MI
N.
(4) #5 BARS, CONT.
#6 BARS @ 12" O.C.
CONCRETE FOOTING
DRAIN PIPE TO DAYLIGHT
4"
4" 8"
APPROX. GRADE
DASHED LINE
INDICATES
FILTER FABRIC
6" MIN.
NO. 1 AGGREGATE
STONE BACKFILL
FOR DRAINAGE TO
WEEPHOLE (AASHTO
NO. 8, 57 OR 67
AGGREGATE)
#5 HORIZ. BARS
@ 12" O.C.
#6 VERT. BARS W/ HOOK
@ 12" O.C. (CENTERED
IN WALL)
(SPLICE BARS AS REQ'D.)
WEEP HOLES @
48" O.C.
GRADE, SEE SITE
PLANS
CONCRETE
RETAINING WALL
STONE FACADE
DATE: SCALE:
PROJECT NO.: DRAWN BY: JEM
AS NOTED
03-03-2026
226 FROGTOWN ROAD
CLIMBERS RUN NATURE CENTER
PEQUEA, PA 17565
PROPOSED TIMBER WALKWAYS AND
FOUNDATIONS FOR:
STRUCTURAL SPECIFICATIONS AND GENERAL CONDITIONS
GENERAL
1. Where these specifications conflict with other project specifications, these specifications shall govern.
2. Durst & Taylor Structural Engineering, LLC will assume no responsibility and/or liability for problems which arise from failure to follow these plans, specifications, and the design intent they convey or for problems which arise from others' failure to obtain and/or follow the Engineer's guidance.
3. All work shall be performed in accordance with local applicable codes and regulations. Appropriate safety measures satisfying local and OSHA requirements shall be provided.
4. Proper temporary bracing of all construction work in progress is the Contractor's responsibility.
5. If during demolition existing conditions do not agree with information shown on the design drawings, the Contractor shall notify the Engineer immediately.
6. The Contractor shall be responsible for the location and protection of all existing utilities during construction and the repair of any damaged facilities.
7. Sections and details shown, while drawn for specific locations, are intended to establish the general types of details to be used throughout.
8. Drawings should not be scaled. Contact the Engineer for clarification of any dimension in question.
9. Anchor bolt layout shall be performed under the direction of a professional land surveyor.
10. All dimensions shall be verified by the Contractor. Layout shall be checked and coordinated between all construction documents and specifications prior to the start of work.
11. Shop drawings prepared by the subcontractors, suppliers, etc. shall be reviewed by the Engineer for conformance with design concept only. Each shop drawing submitted shall be stamped, initialed and dated as being reviewed by the construction manager/general contractor. Work shall not begin without the review by the Engineer.
12. Any engineering design provided by others and submitted for review or record shall bear the stamp and signature of a professional structural engineer registered in the state in which the project is located.
DESIGN DATA
1. Building Code = 2021 International Building Code
2. Floor Load:
2.1. Dead Load = 15 PSF (includes structure weight)
2.2. Live Loads = 100 PSF
3. Snow Load: (Roof Live Load May Control)
3.1. Ground Snow Load, Pg = 30 PSF
3.2. Min. Roof Snow Load = 30 PSF
3.3. Flat Roof Snow Load, Pf = 24.5 PSF
3.4. Snow Exposure Factor, Ce = 1.0
3.5. Snow Load Importance Factor, Is = 1.0
3.6. Thermal Factor, Ct = 1.0
4. Wind Load:
4.1. Basic Wind Speed (3-second gust) = 115 MPH
4.2. Wind Importance Factor, Iw = 1.0
4.3. Building Category = II
4.4. Exposure Category = C
4.5. Internal Pressure Coefficient, GCpi = ±0.18
5. Earthquake Design Data:
5.1. Building Category = II
5.2. Seismic Importance Factor, Ie = I.0
5.3. Mapped Spectral Response Accelerations:
5.3.1. Ss = 0.19
5.3.2. S1 = 0.048
5.4. Site Class = D (assumed)
5.5. Spectral Response Coefficients:
5.5.1. Sds = 0.202
5.5.2. Sd1 = 0.076
5.6. Seismic Design Category = B
5.7. Basic Seismic Force-Resisting System = Cantilever Column
5.8. Design Base Shear = 3 Kip (0.7E For ASD Load Combinations/1.0E for LRFD Load Combinations)
5.9. Seismic Response Coefficient, Cs = 0.20
5.10. Response Modification Factor, R = 1.25
5.11. Analysis Procedure = Equivalent Lateral Force Procedure
6. Concrete Design Method:
6.1. Design per LRFD
6.2. Loads indicated are ASD loads
7. Structural Steel Design Method:
7.1. Design per ASD
7.2. Loads indicated are ASD loads
8. Wood Framing Design Method:
8.1. Design per ASD
8.2. Loads indicated are ASD loads
SPECIAL INSPECTION REQUIREMENTS
1. The following types of work require special inspection based on Section 1704 of the 2018 International Building
Code. The owner will employ special inspectors who shall provide special inspections for compliance with the construction documents and other references noted. Reports shall be submitted to the Engineer and Building Official on a periodic basis. A final report shall be submitted documenting required special inspections and correction of any discrepancies prior to the end of construction.
1.1. Soils
1.1.1. Verify materials below footings are adequate to achieve the design bearing capacity.
1.1.2. Verify excavations are extended to proper depth and have reached proper material.
1.1.3. Verify use of proper materials, densities, and lift thicknesses during placement and compaction of controlled fill with a total depth greater than 12".
1.1.4. Prior to placement of controlled fill, observe subgrade and verify that site has been prepared properly.
CONSTRUCTION PROCEDURES AND SAFETY REQUIREMENTS
1. The contract structural drawings and specifications represent the finished structure. Unless otherwise indicated, they do not indicate the means or methods of construction.
2. Provide all measures necessary to protect the workmen and other persons during construction. Provide all necessary measures to avoid excessive stresses and to hold the structural elements in place during construction.
Such measures shall include, but not be limited to, bracing, shoring for construction equipment, shoring for earth banks, forms, scaffolding, planking, safety nets, support and bracing for cranes and hoists, guying, etc.
3. Engage properly qualified persons to determine where and how temporary precautionary measures shall be used.
Observation visits to the site by structural engineer's field representative shall not include the items noted above.
4. Supervise and direct the work so as to maintain sole responsibility for all construction means, methods, techniques, sequences, and procedures. Retain the services of a professional structural engineer licensed in the state in which the project is located to design and supervise any scaffolding for workmen, and all shoring of forms and elements of the construction.
FOUNDATION CONSTRUCTION
1. Allowable soil bearing pressure (net) assumed in design is 3000 PSF (pounds per square foot) (assumed).
2. Soil bearing capacity shall be field verified by an approved soil testing agency and documented in writing to the
Engineer.
3. If soil of design capacity is not encountered at footing elevations shown, excavate to a depth necessary to attain design capacity and extend foundations as required. Obtain Engineer's approval prior to lowering the foundations.
4. The bottoms of all exterior footings shall extend a minimum of 3'-0" below finished grade unless noted otherwise.
5. Excavate all foundations to reasonable exact outline and depth avoiding over-excavation and cave-in of surrounding material. Bottoms of all foundations shall be dry, soil proof-rolled, and rock surfaces leveled and cleared of loose debris prior to pouring.
6. Neatly level and trim all foundation excavations prior to setting steel.
7. Pipes extending under footings shall be placed before footing is placed and the void produced in laying the pipe shall be filled with 3000 psi concrete.
8. Thoroughly compact all foundation and slab subgrade material prior to placement of stone bases or concrete.
9. Provide weathertight covering for all foundations after excavation; do not expose to rainwater or freezing.
10. Where foundations are formed, backfill edges immediately after form removal.
11. No fill or backfill shall be placed against retaining or foundation walls until grout or concrete has attained design strength and supporting members are in place, unless prior written approval is obtained from the Engineer.
12. All backfill shall be granular material approved by the Engineer and deposited and machine compacted in 8-inch maximum layers. Compaction shall be a minimum of 95% of the maximum dry weight density at the optimum moisture content in accordance with ASTM D1557 (Modified Proctor) as verified by a testing laboratory.
13. All backfill adjacent to retaining structures shall be compacted using hand operated equipment; no heavy equipment shall be allowed within 5 feet of any wall.
14. For all foundation construction that will be exposed to freezing temperatures during construction, the bottom of all footings (interior and exterior) shall extend a minimum of 3'-0" below grade (at no additional cost to the owner).
Contractor shall contact the Engineer of Record for approval to lower foundations and obtain concrete pier sizes, if necessary.
WOOD FRAMING
1. All work shall be performed in accordance with the National Design Specification for Wood Construction, latest edition, as issued by the AFPA.
2. All materials, unless noted otherwise, shall be as follows:
2.1. All lumber to be treated for UC4B use category per AWPA.
2.2. Studs, plates, ledgers, and bracings = Southern pine No. 2 or better.
2.3. Joists and beams = Southern pine No. 2 or better.
2.4. Posts = Southern pine No. 2 or better.
2.5. Moisture content of all structural lumber shall be 19% maximum as verified by stamp.
2.6. All hardware for pressure-treated lumber, fire-retardant-treated lumber, or other exterior lumber shall be stainless steel (grade 304 or better).
S?.?
A
S?.?
SHEET NUMBER
ELEVATION DESIGNATION
SHEET NUMBER
SECTION DESIGNATION
GENERAL LEGEND
- PROPOSED CONDITIONS"TEXT"
"Text" - EXISTING CONDITIONS
CAST-IN-PLACE CONCRETE
S?.?
A
SHEET NUMBER
PLAN DETAIL DESIGNATION
- MOMENT CONNECTION
LEGEND OF ACRONYMS & ABBREVIATIONS
ARCH. - ARCHITECTURAL
- BOTTOM OF FOOTINGB.O.F.
- CLEARCLR.
- COLUMNCOL.
- CONCRETECONC.
- CONTINUOUSCONT.
- DIAMETER (USE Ø WHEN POSSIBLE)DIA.
- DOWNDN.
- EACHEA.
- EACH FACEE.F.
- EQUALEQ.
- EACH WAYE.W.
- ELEVATIONELEV.
- FOOTINGFTG.
- FINISHED FLOORF.F.
- HORIZONTALHORIZ.
- INSIDE FACEI.F.
- LONG LEG HORIZONTALL.L.H.
- LONG LEG VERTICALL.L.V.
- CONCRETE MASONRY UNITCMU
BRG. - BEARING
- WELDED WIRE REINFORCINGW.W.R.
- WITH
- VERTICAL
- UNLESS NOTED OTHERWISE
W/
VERT.
U.N.O.
- TYPICALTYP.
- TOP OF FOOTING
T.O.S. - TOP OF STEEL
T.O.F.
- MAXIMUMMAX.
THK. - THICK
- SECTIONSECT.
- SIMILARSIM
- REINFORCING
- RADIUS
PSF
PSI
PLF
REQ.
REINF.
RET.
RAD.
- POUNDS PER LINEAL FOOT
- POUNDS PER SQUARE FOOT
- POUNDS PER SQUARE INCH
- REQUIRED
- RETURN
- TOP & BOTTOMT & B
BLDG. - BUILDING
DIM. - DIMENSION
DWG. - DRAWING
ELEC. - ELECTRIC/ELECTRICAL
EQUIP. - EQUIPMENT
EXT. - EXTERIOR
- GAGE OR GAUGE
- GALVANIZEDGALV.
GA.
- HEATING/VENTILATION/AIR CONDITIONINGHVAC
INT. - INTERIOR
PennDOT - PENNSYLVANIA DEPT. OF TRANSPORTATION
- OUTSIDE FACE
- ON CENTER
O.F.
O.C.
- USE FOR "AT" WHEN APPROPRIATE@
& - USE FOR "AND" WHEN APPROPRIATE
MISC. - MISCELLANEOUS
MFR. - MANUFACTURER
EX. - EXISTING
- SPACESPC.
ALUM. - ALUMINUM
A.F.F. - ABOVE FINISHED FLOOR
A.C.T. - ACOUSTICAL CEILING TILE
BLK. - BLOCK
- CARPETC.
- CEILINGCLG.
- CAST-IN-PLACEC.I.P.
- DEEPD. OR DP.
- FIRE EXTINGUISHERF.E.
- FIRE EXTINGUISHER WITH CABINETF.E./C
- FINISHED GRADEF.G.
FLR. - FLOOR
FIN. - FINISH (ED)
FIB. - FIBERGLASS
- BAR DIAMETERd b
- GYPSUMGYP.
- GYPSUM DRYWALLGPDW.
- HEIGHTHGT.
- HOLLOW METALH.M.
INSUL. - INSULATION
- LENGTHL.
- METALMET.
N.I.C. - NOT IN CONTRACT
NO. - NUMBER
PNT. - PAINT
PWD. - POWDER
- SEALERSLR.
- STAINLESS STEELS.S.
- STEELSTL.
T.O.W. - TOP OF WALL
- VINYLV.
- VARIESVAR.
- VINYL COMPOSITION TILEV.C.T.
- WIDE/WIDTHW.
- WOODWD.
BTWN. - BETWEEN
- CENTERLINECL
BL - BUILDING LINE
PL. - PLATE
- ENGINEER(S)/ENGINEERINGENG.
MIN. - MINIMUM
ADDL. - ADDITIONAL
- SLIP CRITICALSC
KEY PLAN
NOT TO SCALE
WALKWAY TO
POND
EASTERN
WALKWAY
NORTH
2026-03-03
EASTERN WALKWAY
SCALE: 1/8"=1'-0"
NORTH
FOUNDATION/FRAMING PLAN FOR
8x8 8x
8x
8x
8x
8x
8x8
4x8
4x8 4x8
4x8 4x8
4x8
4x8
4x8 4x8
4x8
4x8
4x8
4x8'S @ 16" O.C., MAX., TYP.
4x8'S @ 16" O.C., MAX., TYP.
S1.1
INDICATES HELICAL PILE, TYP.
DESIGN OF HELICAL PILE BY HELICAL PILE
SUPPLIER'S ENGINEER. REFER TO
SECTION FOR ADDITIONAL INFORMATION
THREE MIDDLE HELICAL PILES TO BE
DESIGNED FOR:
DEAD LOAD = 2,000 POUNDS
LIVE LOAD = 8,000 POUNDS
WIND X = 1,500 POUNDS (1.0WL)
WIND Z = 1,500 POUNDS (1.0WL)
NET UPLIFT = 2,500 POUNDS
20'-7 3/16"
4x8'S @ 16" O.C., M
AX.
4x8
4x8
8x8
4x8
4x8
4x8
4x8
8x
8x
4x8
4x8
4x8
4x8
4x8
4x8
8x
EXTEND 2'-0" BEYOND END
OF PATH, BOTH SIDES;
9'-0" TOTAL WIDTH
EXTEND 2'-0" BEYOND END
OF PATH, BOTH SIDES;
9'-0" TOTAL WIDTH
S1.1
NOTE:
SEE CIVIL PLAN FOR ALL ELEVATIONS/GRADES,
INCLUDING TIE-INS TO TRAILS.
SCALE: 1"=1'-0"
SECTION
S1.1
5 1/2"
6"
1'-3"
4"
2"
1'-4" 1'-4" MAX., TYP.
HELICAL PILES BY GOLIATH TECH
SCREW PILE'S (OR EQUAL) (FINAL
DESIGN BY HELICAL PILE SUPPLIER)
DEAD LOAD = 1,000 POUNDS
LIVE LOAD = 4,000 POUNDS
WIND X = 1,100 POUNDS (1.0WL)
WIND Z = 1,100 POUNDS (1.0WL)
NET UPLIFT = 2,500 POUNDS
6"
MI
N.
- 2
1"
MA
X.
PROPOSED OR
EXISTING GRADE
INTERIOR JOIST
MEMBERS TO BE
4x8'S, TYP.
EDGE MEMBERS TO
BE 4x8'S, TYP.
GIRDER TO BE 8x8
HELICAL PILE SUPPORT
(FINAL DESIGN BY HELICAL PILE
SUPPLIER)
COORDINATE BRACKET HEIGHT
AND LENGTH WITH SUPPLIER
TIMBER DECKING TO BE
BLACK LOCUST NO. 1 FOR
DECKING. PROVIDE 1/4" MAX.
GAP BETWEEN DECK BOARDS
6x8 WOOD
CURB, TYP.
(2) 1/2" DIA. THRU
BOLTS (HOT DIP
GALVANIZED), TYP.
2" 4x8 CONNECTED W/ SIMPSON CJT3Z WITH (6) 1/4" x 3" SDS
FASTENERS TO GIRDER AND (3)
1/2" JOIST PINS TO JOISTS
(PROVIDE ADDTIONAL
CORROSION PROTECT FOR
SIMPSON PRODUCT)
4x8 CONNECTED W/ SIMPSON CJT3Z WITH
(6) 1/4" x 3" SDS FASTENERS TO GIRDER
AND (3) 1/2" JOIST PINS TO JOISTS
(PROVIDE ADDTIONAL CORROSION
PROTECT FOR SIMPSON PRODUCT)
NOTES:
1. ALL LUMBER TO BE SOUTHERN PINE #2 OR BETTER.
2. ALL LUMBER TO BE TREATED FOR UC4B USE CATEGORY PER AWPA.
3. REFER TO SIMPSON TECH BULLETIN CJTZ/HCJTZ - CONCEALED
JOIST TIE KITS FOR ADDITIONAL INFORMATION.
(https://sstoolbox.widen.net/view/pdf/va5ozl1nq 2/T-C-CJTZ24.pdf?t.download=true&u=cjmyin)
SCALE: 1"=1'-0"
TYPICAL ABUTMENT SECTION
S1.1
1'- 4"
MI
N.
- 2 '-6
" M
AX
3'-
0"
MI
N.
PAVING, SEE SITE PLANS 8"
2'-9" MIN.
1'- 0"
1'-4" MIN.
WOOD DECK ATTACHED WITH
STAINLESS STEEL SCREWS
ABU46Z (STAINLESS STEEL), ATTACHED TO CONCRETE WITH
5/8" DIA. x 5" LONG STAINLESS STEEL SIMPSON TITEN HD.
NAIL TO JOIST WITH (12) 0.162" DIA. x 3 1/2" LONG SS NAILS
SLOPE TOP OF
CONCRETE TO AVOID
WATER FROM PONDING
WOOD JOIST
AT CONTRACTOR'S OPTION, INSTEAD OF POURING
A FOOTING AND WALL, A 2'-9" THICK ABUTMENT
WALL CAN BE PLACED. REINFORCE WITH #6 BARS
@ 12" O.C., EACH WAY, EACH FACE
CONCRETE WALL W/ #5 BARS @ 12" O.C.,
EACH WAY, EACH FACE OF ABUTMENT
6"
MI
N.
DATE: SCALE:
PROJECT NO.: DRAWN BY: JEM
AS NOTED
03-03-2026
226 FROGTOWN ROAD
CLIMBERS RUN NATURE CENTER
PEQUEA, PA 17565
PROPOSED TIMBER WALKWAYS AND
FOUNDATIONS FOR:
2026-03-03
4x8
WALKWAY TO POND
SCALE: 1/8"=1'-0"
NORTH
FOUNDATION/FRAMING PLAN FOR
10' -0"
MAX., T
YP.
6x8
6x8
6x8
6x8
4x8 @ 16" O.C., MAX., TYP.1 S1.2
8x14
8x14
8x14
8x
8x
8x
8x
8x
8x
8x14
8x14
8x1
8x1
8x1
8x1
8x8
6x8
6x8
6x8
6x8
6x8
6x8
6x8
6x8
6x8
8x 10 8x14
6x8
8x
S1.2
10'-0" MAX., TYP.
(CENTER TO CENTER)
INDICATES LOCATION
OF GUARDRAIL
CONNECT 6x8 TO 6x8 WITH
SIMPSON HUC66 STAINLESS
STEEL JOIST HANGER
CONNECT 4x8 TO 8x8 WITH
SIMPSON HU48 STAINLESS
STEEL JOIST HANGER, TYP.
4x8 @ 16" O.C., MAX., TYP
4x8 @ 1
6" O.C., MAX., TY
P.
4x8 @ 1
6" O.C., MAX., TY
P.
4x84x84x84x84x84x8
4x84x84x84x84x84x84x8
INDICATES HELICAL PILE, TYP.
DESIGN OF HELICAL PILE BY HELICAL PILE
SUPPLIER'S ENGINEER. REFER TO
SECTION FOR ADDITIONAL INFORMATION
7'-0"
7'-5"
7'-0"
7'-5 "10'
-0"
22'-4"
5'-8"
5'-8"
COORDINATE ALL
DIMENSIONS WITH THE SITE
PLANS AND THE POND
RESTORATION PLANS
4x8 @ 1
6" O.C., MAX., TY
P.4 S1.1
8'- 0"
EXTEND 2'-0" BEYOND END
OF PATH, BOTH SIDES;
9'-0" TOTAL WIDTH
4x8
GIRDERS TO THE SOUTH
SHALL BE DROP FRAMED
SIMILAR TO SECTION 1/S1.2
GIRDERS TO THE NORTH
SHALL BE FLUSH FRAMED
SIMILAR TO SECTION 2/S1.2
JOIST TO FRAME INTO THE
SIDES OF THIS GIRDER,
SIMILAR TO SECTION 2/S1.2
DROP THIS 8x14 GIRDER, SO THAT JOISTS BEAR ON
TOP OF 8x14 GIRDER, SIMILAR TO SECTION 1/S1.2
NOTE:
SEE CIVIL PLAN FOR ALL ELEVATIONS/GRADES,
INCLUDING TIE-INS TO TRAILS.
SCALE: 1"=1'-0"
SECTION
S1.2
5"
6"
1"5 1/2"5"1'-3"
4"
7 1 /2"
1 3 /4"
3'- 6"
1 1 /2"2"
4 1/2"
1'-4" 1'-4" MAX., TYP.
HELICAL PILES BY GOLIATH TECH
SCREW PILE'S ( OR EQUAL) (FINAL
DESIGN BY HELICAL PILE SUPPLIER)
DEAD LOAD = 1,000 POUNDS
LIVE LOAD = 4,000 POUNDS
WIND X = 1,100 POUNDS (1.0WL)
WIND Z = 1,100 POUNDS (1.0WL)
NET UPLIFT = 2,500 POUNDS
1'- 0"
MI
N.
TOP OF WATER
6x8 CONNECTED W/ (3) #10
STAINLESS STEEL SCREWS
EACH SIDE OF PURLIN
4x8 CONNECTED W/
(3) #10 STAINLESS
STEEL SCREWS
EACH SIDE OF
PURLIN, TYP.
INTERIOR JOIST
MEMBERS TO BE
4x8'S, TYP.
EDGE MEMBERS TO
BE 6x8'S, TYP.
GIRDER TO BE 8x14
4" O.C.
TIMBER DECKING TO BE
BLACK LOCUST NO. 1 FOR
DECKING. PROVIDE 1/4" MAX.
GAP BETWEEN DECK BOARDS
(2) 6" LONG, 3/4" DIA. LAG SCREWS
(STAINLESS STEEL), TYP.
2"HELICAL PILE SUPPORT
(FINAL DESIGN BY HELICAL PILE
SUPPLIER)
COORDINATE BRACKET HEIGHT
AND LENGTH WITH SUPPLIER
SCALE: 1"=1'-0"
SECTION
S1.2
5 1/2"
6"
1'-3"
4"
4"
1'-4" 1'-4" MAX., TYP.
HELICAL PILES BY GOLIATH TECH
SCREW PILE'S (OR EQUAL) (FINAL
DESIGN BY HELICAL PILE SUPPLIER)
DEAD LOAD = 1,000 POUNDS
LIVE LOAD = 4,000 POUNDS
WIND X = 1,100 POUNDS (1.0WL)
WIND Z = 1,100 POUNDS (1.0WL)
NET UPLIFT = 2,500 POUNDS
6"
MI
N.
- 1
9"
MA
X.
PROPOSED OR
EXISTING GRADE
4x8 CONNECTED W/ SIMPSON CJT3Z WITH
(6) 1/4" x 3" SDS FASTENERS TO GIRDER
AND (3) 1/2" JOIST PINS TO JOISTS
(PROVIDE ADDTIONAL CORROSION
PROTECT FOR SIMPSON PRODUCT)
INTERIOR JOIST
MEMBERS TO BE
4x8'S, TYP.
EDGE MEMBERS TO
BE 4x8'S, TYP.
GIRDER TO BE 8x102"
HELICAL PILE SUPPORT
(FINAL DESIGN BY HELICAL PILE
SUPPLIER)
COORDINATE BRACKET HEIGHT
AND LENGTH WITH SUPPLIER
TIMBER DECKING TO BE
BLACK LOCUST NO. 1 FOR
DECKING. PROVIDE 1/4" MAX.
GAP BETWEEN DECK BOARDS
6x8 WOOD
CURB, TYP.
(2) 1/2" DIA. THRU
BOLTS (HOT DIP
GALVANIZED), TYP.
(2) 1/2" DIA. THRU
BOLTS (HOT DIP
GALVANIZED), TYP.
9"
GUARDRAIL TO MATCH
GUARDRAIL WHICH IS BEING
INSTALLED AT BOARDWALK
AND PATIO ADJACENT TO
THE BARN STRUCTURE. SEE
DETAIL FROM
ARCHITECTURAL PLANS FOR
REFERENCE
NOTES:
1. ALL LUMBER TO BE SOUTHERN PINE #2 OR BETTER.
2. ALL LUMBER TO BE TREATED FOR UC4B USE CATEGORY PER AWPA.
3. REFER TO SIMPSON TECH BULLETIN CJTZ/HCJTZ - CONCEALED
JOIST TIE KITS FOR ADDITIONAL INFORMATION.
(https://sstoolbox.widen.net/view/pdf/va5ozl1nq 2/T-C-CJTZ24.pdf?t.download=true&u=cjmyin)
4x8 CONNECTED W/ SIMPSON CJT3Z WITH (6) 1/4" x 3" SDS
FASTENERS TO GIRDER AND (3)
1/2" JOIST PINS TO JOISTS
(PROVIDE ADDTIONAL
CORROSION PROTECT FOR
SIMPSON PRODUCT)
NOTES:
1. ALL LUMBER TO BE SOUTHERN PINE #2 OR BETTER.
2. ALL LUMBER TO BE TREATED FOR UC4B USE CATEGORY PER AWPA.
3. REFER TO SIMPSON TECH BULLETIN CJTZ/HCJTZ - CONCEALED
JOIST TIE KITS FOR ADDITIONAL INFORMATION.
(https://sstoolbox.widen.net/view/pdf/va5ozl1nq 2/T-C-CJTZ24.pdf?t.download=true&u=cjmyin)
DATE: SCALE:
PROJECT NO.: DRAWN BY: JEM
AS NOTED
03-03-2026
226 FROGTOWN ROAD
CLIMBERS RUN NATURE CENTER
PEQUEA, PA 17565
DETAILS ARE FROM ARCHITECTURAL DRAWINGS
BY TWA FOR CLIMBERS RUN NATURE CENTER
PROJECT. GUARDRAIL FOR DOCK TO BE
SIMILAR TO THE GUARDRAIL AT THE PATIO AND
BOARDWALK FOR THE BARN RENOVATIONS.
PROPOSED TIMBER WALKWAYS AND
FOUNDATIONS FOR:
2026-03-03
PROVIDE HEMMED
COPPER CAP, MIN.
24GA W/ 1/2" HEMMED
SIDES; TYP. @ ALL
EXPOSED BEAM TOPS