10-6-DA27007-24437520 Residence Property Preparation Utilities.pdf

PDF 10 MB Posted

Attached to
DFCM Construction - VBS Design Build - DNR/DWR - Logan Fish Hatchery Residence - 24437520
Solicitation number
DA27007
Issued by
Utah

About this file

This is a Residence Property Preparation Utilities document for the State of Utah Division of Facilities Construction and Management (DFCM) Logan Fish Hatchery Residence Design-Build project. The project entails construction of a single-story, 2,000 square foot rambler on the Logan Fish Hatchery property with a maximum design-build budget of $500,000.00. The Design-Build team is typically comprised of a General Contractor supported by subcontractors and a design firm with supporting consultants; however, the project structure may vary from this standard configuration. The document addresses utilities preparation requirements necessary to support the residential construction at the hatchery facility.

The utilities preparation specifications establish the baseline infrastructure and service requirements that must be in place prior to and during construction of the residence. These preparations ensure that adequate water, sewer, electrical, gas, and other utility systems are available to support the new 2,000 square foot residential structure within the existing Logan Fish Hatchery campus environment. The utilities work must be coordinated with the overall design-build process to meet the project budget constraints and functional requirements of a low-maintenance residential facility.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

x x x x x x

PRELIMINARY

DRAWING

NOT FOR

CONSTRUCTION

CARETAKER RESIDENCE BUILDING

LOGAN HATCHERY IMPROVEMENT PROJECT

C-101

PAGE NO:DATE:

QA

NO. REVISIONS

DESIGNED

DRAWN

DATEBY

SHEET NO:

PROJECT NO:

This document or any part thereof in detail or design concept is the property of Forsgren Associates Inc. and shall not be copied without the written authorization of Forsgren Associates Inc.

AT 24"x36" SIZE

LINE IS 2-INCHES

ATTENTION

APPROVED

9 5 W E S T 1 0 0 S O U T H , S T E . 1 1 5 , L O G A N , U T 8 4 3 2 1

PH: 435.227.0333 FAX: 435.227.0334

IF NOT 2-INCHES,

SCALE DRAWING ACCORDINGLY

14-24-0189

PUBLISHED

1465 WEST 200 NORTH

LOGAN, UTAH 84321

LOGAN FISH HATCHERY

UTAH DIVISION OF WILDLIFE RESOURCES

DFCM CODE COMPLIANCE OFFICER

0 15' 30'

SCALE: 1" = 15'

7.5'

N

02-25-2025

EXISTING TREE TO BE

REMOVED

EXISTING TREE TO BE

REMOVED

EXISTING TREE STUMP TO

BE REMOVED

EXISTING TREE TO BE

REMOVED EXISTING TREE TO BE

REMOVED

EXISTING SHED TO BE

RELOCATED. COORDINATE

W/ OWNER

EXISTING DOG ENCLOSURE

FENCING TO BE TO BE

REALIGNED BY OWNER

EXISTING STORMWATER

MANHOLE TO BE REMOVED

REMOVE LOOSE ROCK IN EXISTING

DETENTION BASIN. EXCAVATE TO

SUITABLE SUB-GRADE. FILL W/

COMPACTED STRUCTURAL FILL

EXISTING CONCRETE

DRIVE TO BE REMOVED

EXISTING GARBAGE BIN

AND BASKETBALL HOOP

TO BE RELOCATED

YARD HYDRANT AND FILL STATION TO

BE REMOVED, CONSULT OWNER FOR

SALVAGE OF EQUIPMENT OR DISPOSE

OF AS DIRECTED

WWAB PROJECT UNDER

CONSTRUCTION

DEMOLITION NOTES:

1. CLEAR AND GRUB TO REMOVE VEGETATION AND

TOPSOIL TO SUITABLE SUB-GRADE SOIL UNDER

BUILDING FOOTPRINT AND UNDER SITE CONCRETE.

EXTEND MIN. 1' BEYOND FOOTINGS OR CONCRETE.

PROVIDE COMPACTED STRUCTURAL FILL AS REQUIRED

TO MATCH SUB-GRADE ELEVATION. COMPACT IN 6"

LIFTS TO 95% MODIFIED PROCTOR DENSITY.

2. TREES DESIGNATED FOR REMOVAL SHALL BE TAGGED

BY CONTRACTOR AND APPROVED BY OWNER'S

REPRESENTATIVE PRIOR TO REMOVAL OF THE TREES.

DEMOLITION PLAN

REMOVE AND REPLACE FENCE

AS REQUIRED FOR SEWER

CONSTRUCTION

SAWCUT AND REMOVE

ASPHALT FOR SEWER

SYSTEM INSTALLATION

EXISTING TREE TO BE

REMOVED

2/25/25

CONTRACTOR

SHALL REMOVE

DIVISION OF FACILITIES

CONSTRUCTION AND

MANAGEMENT

REVIEWED FOR

CODE COMPLIANCE

THOMAS PETERSON

05/19/2025 x x x

NEW 48" DIA. SSMH LIFT STATION

STA=10+95.69

RIM=4443.78

FL IN=4438.70 (NE)

FL IN=4436.46 (NW)

FL OUT=4438.79 (S)

0 L

F - 4 " P

VC @

S=2.0

0%

EXIST. SSMH

STA=13+97.05

RIM=4444.00

FL IN=4437.75 (N)

305 LF - 8" PVC @ S=0.34%S

CO

13+97

10+00

11+00 12+00

13+00

CO

CO

CO

W as he r

D ry er

UP

CO

S

CO

9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00

100 LF - 4" PVC @ S=2.00%

305 LF - 8" PVC @ S=0.34%

NEW 4"CLEANOUT

STA=10+00.00

RIM=4443.10

FL OUT=4438.37 (SE)

NEW 48" DIA. SSMH LIFT STATION

STA=10+95.69

RIM=4443.78

FL IN=4438.70 (NE)

FL IN=4436.46 (NW)

FL OUT=4438.79 (S)

EXIST. SSMH

STA=13+97.05

RIM=4444.00

FL IN=4437.75 (N)

C-103GENERAL PROJECT CONSTRUCTION

SANITARY SEWER P&P & UTILITY PLAN

PAGE NO:DATE:

QA

NO. REVISIONS

DESIGNED

DRAWN

DATEBY

SHEET NO:

PROJECT NO:

This document or any part thereof in detail or design concept is the property of Forsgren Associates Inc. and shall not be copied without the written authorization of Forsgren Associates Inc.

AT 24"x36" SIZE

LINE IS 2-INCHES

ATTENTION

APPROVED

9 5 W E S T 1 0 0 S O U T H , S T E . 1 1 5 , L O G A N , U T 8 4 3 2 1

PH: 435.227.0333 FAX: 435.227.0334

IF NOT 2-INCHES,

SCALE DRAWING ACCORDINGLY

14-24-0189

PUBLISHED

1465 WEST 200 NORTH

LOGAN, UTAH 84321

LOGAN FISH HATCHERY

UTAH DIVISION OF WILDLIFE RESOURCES

DFCM CODE COMPLIANCE OFFICER

0 20' 40'

SCALE: 1" = 20'

10'

SCALE

VERTICAL 1" = 2'

HORIZONTAL 1" = 20'

NOTE: CONTRACTOR

TO VERIFY UTILITY

CROSSINGS IN FIELD

NEW CARETAKER

RESIDENCE SEWER

LATERAL CONNECTION

EXISTING RESIDENCE SEWER

LATERAL CONNECTION

2" WATERLINE

CROSSING

GAS LINE

CROSSING

GAS LINE

CROSSING

GAS LINE

CROSSING

SEWER LINE

CROSSING

8" WATERLINE

CROSSINGS

EXISTING SURFACE

EXISTING RESIDENCE SEWER LATERAL

SEWER LATERAL 70 LF - 4" PVC @ S=2.0% MIN.

EXISTING UTILITY LINE TO BE ABANDONED IN PLACE

RV PAD SEWER INV=4441.27

PER U.D.O.T. PLANS

SEWER INV = 4437.65±

PRELIMINARY

DRAWING

NOT FOR

CONSTRUCTION

EXISTING 4" CLEANOUT

EXISTING RAS BUILDING

SEWER LATERAL

CONNECTION

EXISTING RAS BUILDING SEWER LATERAL

CARETAKER RESIDENCE BUILDING

LOGAN HATCHERY IMPROVEMENT PROJECT

SUMP INV=4435.00

(SEE SHEET C-104)

CONTRACTOR TO VERIFY DEPTH AND LOCATION

OF EXISTING LATERAL AND CONNECT TO NEW

SEWER CLEANOUT. PLUG EXISTING SERVICE

DOWNSTREAM OF CONNECTION

N

SANITARY LOCATION

COORDINATE W/ UTILITY PURVEYOR AND INSTALL GAS

SERVICE

APPROXIMATE ELECTRICAL SERVICE

(SEE ELECTRICAL PLAN)

LIFT STATION CONTROL PANEL - PROVIDE

CONDUIT AND POWER FROM HOUSE PANEL

AND TO LIFT STATION

2" POLYETHYLENE SERVICE TUBING

CONNECT TO BUILDING PLUMBING

NOTE:

ALL METAL FITTINGS SHALL

BE GREASED AND WRAPPED

IN 15 MIL PLASTIC.

WATER SERVICE CONNECTION FROM EXISTING LINE

CONTRACTOR TO VERIFY DEPTH, SIZE AND LOCATION

OF EXISTING LINE PRIOR TO CONNECTION

EXISTING BOLLARD

EXISTING ELECTRICAL CABINET

PROVIDE CONDUIT FROM LIFT STATION TO CONTROL

PANEL AND CONNECT POWER, ALARMS, TO PROVIDE

FULL FUNCTIONALITY FOR THE LIFT STATION

CONNECT TO EXIST. SSMH

STUB-OUT PER U.D.O.T. PLANS.

CONTRACTOR TO VERIFY IN FIELD

02-25-2025

EXISTING POTABLE WATER SPIGOT

EXISTING WATER METER. SERVICE LINE ALIGNMENT

UNKNOWN. SERVICE TO EXISTING CARETAKER

RESIDENCE

CONNECTION TO EXISTING GAS LINE

COORDINATE W/ UTILITY PURVEYOR

RV PAD SEWER LATERAL 62 LF - 4" PVC @ S=2.0% MIN.

EXISTING WATER METER. SERVICE LINE ALIGNMENT

UNKNOWN. SERVICE TO EXISTING BUNK HOUSE,

ADMIN. BUILDING, AND RAS BUILDING TO REMAIN.

TRUCK DISINFECTION/FILL STATION SERVICE TO BE

DEMOLISHED W/ EXISTING WATER SERVICE TO BE

CONNECTED TO NEW CARETAKER RESIDENCE.

APPROXIMATE WATER LINE TO EXISTING SPIGOT.

REMOVE OR ABANDON IN PLACE (PUMP FULL W/

GROUT)

EXISTING SANITARY SEWER MANHOLE TO REMAIN

NEW 4" CLEANOUT

RV PAD SEWER LATERAL

CONECTION

RV PAD SEWER LATERAL 70 LF - 4" PVC @ S=2.0% MIN.

SHEET KEY NOTES:

CONTRACTOR TO VERIFY DEPTH AND LOCATION OF

EXISTING LATERAL AND CONNECT TO NEW SEWER

LINE. PATCH AND REPAIR PAVEMENT AND PLUG

EXISTING SERVICE DOWNSTREAM OF CONNECTION

CONNECT TO EXIST. SSMH STUB-OUT PER U.D.O.T.

PLANS. CONTRACTOR TO VERIFY IN FIELD

SUMP INV=4435.00

(SEE SHEET C-104)

2 3

2/25/25

DIVISION OF FACILITIES

CONSTRUCTION AND

MANAGEMENT

REVIEWED FOR

CODE COMPLIANCE

PAGE NO:DATE:

QA

NO. REVISIONS

DESIGNED

DRAWN

DATEBY

SHEET NO:

PROJECT NO:

This document or any part thereof in detail or design concept is the property of Forsgren Associates Inc. and shall not be copied without the written authorization of Forsgren Associates Inc.

AT 24"x36" SIZE

LINE IS 2-INCHES

ATTENTION

APPROVED

9 5 W E S T 1 0 0 S O U T H , S T E . 1 1 5 , L O G A N , U T 8 4 3 2 1

PH: 435.227.0333 FAX: 435.227.0334

IF NOT 2-INCHES,

SCALE DRAWING ACCORDINGLY

14-24-0189

PUBLISHED

1465 WEST 200 NORTH

LOGAN, UTAH 84321

LOGAN FISH HATCHERY

UTAH DIVISION OF WILDLIFE RESOURCES C-104

GENERAL DETAILS

CARETAKER RESIDENCE BUILDING

LOGAN HATCHERY IMPROVEMENT PROJECT

FOOTING TO BE 6 FT DIA. (72")

AND 6" MIN. THICKNESS

PRELIMINARY

DRAWING

NOT FOR

CONSTRUCTION

DFCM CODE COMPLIANCE OFFICER

OUTLET PIPES AND

APPURTENANCES NOT TO BE

LESS THAN 2"

OUTLET PIPES AND

APPURTENANCES NOT TO BE

LESS THAN 2"

8" SEWER LINE TO EXTEND INTO

MANHOLE TO ALLOW CLEANOUT

OF 8" PIPE AND EMERGENCY

OVERFLOW FOR LIFT STATION

SEE PLAN FOR CONTROL PANEL LOCATION

MOUNT ON UNISTRUT FRAME SET IN

CONCRETE BASE OR AS OTHERWISE

DIRECTED BY OWNER

02-25-2025

PROVIDE DUPLEX PUMP STATION AS SPECIFIED OR APPROVED EQUAL.

PROVIDE 100 FT LEADS

MANHOLE HEIGHT PER PLAN

PROVIDE WATER-TIGHT

SEAL AT MANHOLE

PROVIDE GRANULAR BACKFILL BORROW WITH

BEDDING MATERIAL. BACKFILL COMPACTED TO

95% MODIFIED PROCTOR DENSITY

SEE PLAN

ADJUST FLOAT CONTROL ELEVATIONS TO

ACCOMMODATE INLET AND OUTLET PIPES

2 "

2 "

2.0 IN

2.0 IN

8" PVC PIPE W/ 2" PUMP DISCHARGE LINE

2.0 IN

2.0 IN

2.0 IN

2.0 IN

2.0 IN

100 FT

20 GPM OR 15.0' TDH

.5 HP MIN

115 V

2/25/25

DIVISION OF FACILITIES

CONSTRUCTION AND

MANAGEMENT

REVIEWED FOR

CODE COMPLIANCE

PAGE NO:DATE:

QA

NO. REVISIONS

DESIGNED

DRAWN

DATEBY

SHEET NO:

PROJECT NO:

This document or any part thereof in detail or design concept is the property of Forsgren Associates Inc. and shall not be copied without the written authorization of Forsgren Associates Inc.

AT 24"x36" SIZE

LINE IS 2-INCHES

ATTENTION

APPROVED

9 5 W E S T 1 0 0 S O U T H , S T E . 1 1 5 , L O G A N , U T 8 4 3 2 1

PH: 435.227.0333 FAX: 435.227.0334

IF NOT 2-INCHES,

SCALE DRAWING ACCORDINGLY

14-24-0189

PUBLISHED

1465 WEST 200 NORTH

LOGAN, UTAH 84321

LOGAN FISH HATCHERY

UTAH DIVISION OF WILDLIFE RESOURCES C-105

GENERAL DETAILS

CARETAKER RESIDENCE BUILDING

LOGAN HATCHERY IMPROVEMENT PROJECTPRELIMINARY

DRAWING

NOT FOR

CONSTRUCTION

DFCM CODE COMPLIANCE OFFICER

02-25-2025

CLEANOUT LOCATION

PER PLAN

OR HDPE LANDSCAPE BOX W/ LID IN

NON-PAVED AREA

PROVIDE 12 GUAGE TRACER

WIRE AT PIPE, TYP.

ALL WET UTILITIES

2/25/25

DIVISION OF FACILITIES

CONSTRUCTION AND

MANAGEMENT

REVIEWED FOR

CODE COMPLIANCE

File details come from the government source that posted it. Updated .