Replace Air Handling Units #36 & #37 at Miami VAMC
Closed Solicitation Posted
- Solicitation number
- 36C24823R0008
- Agency
-
Veterans Integrated Service Network 8
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 333415 Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
- Place of performance
- Miami, Florida 33125, United States
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation seeks to replace two aging air handling units at the Miami VA Medical Center. The selected contractor must remove and dispose of existing units 36 and 37, then install two new high-efficiency units with variable frequency drives, direct digital controls, HEPA filters, stack coils, UV lights, and minimum airflow capacities. The contractor shall provide all necessary materials and equipment to complete the project in accordance with technical specifications, prevailing wage determinations, and industry standards set by ASHRAE, NFPA, and others. Proposals are due by December 5, 2022 and will be evaluated based on technical qualifications, past performance, and price.
This requirement has been set aside for verified service-disabled veteran-owned small businesses. The principal NAICS code is 238220 and the predominate PSC code is R499. The place of performance is the Miami VA Medical Center located at 1201 NW 16th Street, Miami, FL 33125. The period of performance is 180 calendar days following notice to proceed with a budget between $500,000-$1,000,000. The soliciting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8.
Notice text
The Contractor shall install a two-unit duct bypass or cross-connect to have a redundant system in case one of the units are down, the second unit can be used to supply air conditioning to both areas. The two (2) new units will have all the specifications below:
- High-Efficiency Particulate Air (HEPA) filters.
- Stack coils (Separated coils for easier maintenance access).
- Total supply air for air handling unit #36 of a least 9,600 cubic feet per minute (CFM).
- Total supply air for air handling unit #37 of a least 9,200 cubic feet per minute (CFM).
- Ductwork shall be double wall insulated.
- VFDs will have a bypass function.
- New units shall have Ultraviolet (UV) light in the system.
- Direct drive plenum fans shall be used in the units.
- Multiple plenum fans (minimum of four per unit) each with a dedicated VFD shall be used in the units.
- 8-rows cooling coils.
- The new units shall have pandemic mode.
The contractor shall provide all materials and equipment necessary to remove and discard the existing air handling units #36 and #37 and to install two new air handling units with VFD function and DDC Controls including, but not limited to:
-Piping and Fittings
-Electrical System
-Metal Duct and Duct Connections (Supply and Return)
-Chill Water and Hot Water Hydronic Black Steel Pipe and Fittings
-Thermal Insulation and Aluminum Jacketing
-Louvers
-Roof Supports for Pipes and Ducts
-DDC Control, Low Voltage Wiring and Integration to Siemens System
-Wind Load Rated Roof Curb and Tie-Down
-Roof Flashing (Curbs, Pipe/Duct Support)
-Rigging and Hoisting
-Test and Balance (Before and After)
The entire work must be Tested and Certified by a Mechanical Professional Engineer (PE) and meets NFPA, EPA, ANSI, OSHA, National Plumbing Code, National Electric Code, ASHRAE, National Safety Code, VA Specifications, VA Construction Standards, VA Design - Build Handbooks and VA Fire Protection Design Manual available in the Technical Information Library (https://www.cfm.va.gov/TIL).
Files
Show all 16
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| 4120--rental of two chillers for one year | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| 648-22-104 Correct HVAC Deficiencies (P&V) | Veterans Integrated Service Network 20 | Service-Disabled Veteran-Owned Small Business | |
| TVHS AC VRF System Installation | Veterans Integrated Service Network 9 | Service-Disabled Veteran-Owned Small Business | |
| Z2NZ--Turn Key Chiller Equipment (Purchase and Install) | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| NTX Steam Trap Monitoring | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity