J045--Grease Trap Maintenance

Closed Pre-Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
36C24826Q0790
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

Place of performance
C.W. Bill Young VA Healthcare System Bay Pines, Florida 33744, United States

Notice details come from SAM.gov. Updated .

About this opportunity

Department of Veterans Affairs Veterans Integrated Service Network 8 is conducting market research via sources-sought notice for grease trap maintenance services at Bay Pines VA Healthcare System in Bay Pines, Florida, with responses due by June 18, 2026 at 2:00 PM Eastern Time. The requirement carries a Service-Disabled Veteran-Owned Small Business set-aside; if insufficient SDVOSB responses are received, the solicitation may be re-released as a Veteran-Owned Small Business or Small Business set-aside open to all eligible competitors.

The contractor shall provide all equipment, personnel, and supervision to remove grease, garbage, and sewage from seven grease traps and six lift stations at the facility. Work is performed at Bay Pines VA Healthcare System, 10000 Bay Pines Blvd. Bay Pines, Florida 33744. Monthly maintenance applies to five locations including Buildings 37, 101, 1, and two tanks at Building 100 (capacities from 400 to 3,500 gallons). Quarterly maintenance covers three locations (Buildings 102, 46, and 111). Semi-annual maintenance applies to five additional locations including Fisher House. Monthly pumping inspections at Building 100 must occur between 4:00 AM and 6:00 AM. The contractor must pressure clean traps and lift stations, obtain Engineering designee signatures upon completion, and provide disposal documentation including disposal site location, gallons disposed, and Pinellas County permit numbers. Monthly inspections occur Tuesday through Thursday during the first ten calendar days of each month; quarterly services are scheduled for October, January, April, and July.

Interested contractors should submit capability statements via email to the contracting officer. NAICS 562998; PSC J045.

Notice text

Good day, SDVOSB s, VOSB s, SB s

This Sources Sought is issued solely for informational and planning purposes only. It does not constitute the issuance of a solicitation or a promise to issue a solicitation in the future. The purpose of this notice is to conduct market research and obtain information from qualified SDVOSB businesses. This is not a request for bids, quotes, offers, or proposals. The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible. If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB s, the requirement may be solicited as a VOSB or a SB set aside in which case all interested parties responding shall be eligible to compete.

Please direct reply in the affirmative via email if you are interested and can provide the required service/product for this requirement. Please provide your capability statement, I will accept responses for this Sources Sought until the 18th of June 2026 at 14:00 EST, thanks.

STATEMENT OF WORK

Contractor shall provide all equipment, personnel, and supervision to remove grease, garbage, and sewage from seven (7) grease traps and six (6) lift stations located at the Bay Pines VA Healthcare System, 10000 Bay Pines Blvd. Bay Pines, FL 33744. This work shall be done in accordance with the following schedule:

MONTHLY:

Building 37 One (1) 400 gallon lift station

Building 101 One (1) 2,000 gallon grease trap

Building 1 One (1) 2,000 gallon grease trap

Building 100 One (1) secondary 3,500 gallon grease trap*** Building 100 One (1) primary 3,500 gallon grease trap*** QUARTERLY:

Building 102 One (1) 400 gallon lift station

Building 46 One (1) 2,000 gallon grease trap

Building 111 One (1) 1,000 gallon grease trap

SEMI-ANNUALY:

Building 1001 NCA Admin- One (1) 400 gallon lift station Building NCA Maintenance- One (1) 400 gallon lift station Building 102 One (1) 1500 gallon grease trap

Fisher House One (1) 400 gallon lift station Building 107 ONE (1) 400 gallon lift station

***NOTE: ALL PUMPING MUST TAKE PLACE DURING THE HOURS OF 4:00AM 6:00AM

Removal of Grease and Garbage: The contractor is required to pump out and remove all water, grease, garbage, sewage, and other matter that has accumulated since the last service in accordance with the schedule. The contractor shall pressure clean traps and lift stations and expose all four sides and the bottom completely.

Disposal of Grease: The Contractor shall be responsible for removal and disposal of all grease, garbage, and debris from VA property. Grease and waste Hauler must be Permitted in Pinellas county. Provide documentation of disposal to include the following: Disposal site location, and amount in gallons disposed.

Inspection and Acceptance: Pumping of all grease traps shall take place on Tuesday, Wednesday, or Thursday during the first ten (10) calendar days of each month. Quarterly pumping of grease traps shall take place during the months of October, January, April and July. Contractor shall notify Stephen Moore, Pipefitter Supervisor . During this notification, arrangements will be made for the Point of Contract (POC) of this contract or his/her designee to accompany the contractor to the site of work. Upon completion of each service the contractor shall obtain the signature of the Engineering designee, as specified, in order to show acceptance/rejection of the service. A clear copy of this transaction shall be given to the Engineering designee. This should include the minimum details: Date, device type location, local identifier, capacity, PO, time, gallons pumped, Interceptor or lift station condition, grease cap, solids removed, disposal location and permit #. Legible copies are to be provided to facility.

Files

File Type Posted
36C24826Q0790.docx DOCX document

Notice history

Notice Type Posted
J045--Grease Trap Maintenance Latest solicitation Solicitation
J045--Grease Trap Maintenance Pre-Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
J045--FY 27 Grease Trap and Lift Station Maintenance C.W. Bill Young VA Healthcare System 10000 Bay Pines Blvd Bay Pines, Florida 33744, United States · NAICS 562998 Veterans Integrated Service Network 8 Total Small Business
J059--629-27-2-690-0002 grease trap maintenance FY27 (VA-27-00006422) 36C256-27-AP-0910 Southeast Louisiana Veterans Healthcare System New Orleans, La 70119 · NAICS 562119 Veterans Integrated Service Network 16 No set-aside
S205--Waste Management and Recycling Services Department of Veterans Affairs Bay Pines Veteran Healthcare Center Bay Pines FL 33744 · NAICS 562111 Veterans Integrated Service Network 8 Service-Disabled Veteran-Owned Small Business
S208--FY27 Holiday Decor Annual Contract See Sow, United States · NAICS 561730 Veterans Integrated Service Network 8 Service-Disabled Veteran-Owned Small Business
SOURCES SOUGHT: Grease, Sand Trap, Oil and Water Separator Ellsworth AFB, South Dakota 57706, United States · NAICS 562998 Air Combat Command No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity