Eisenhower Barracks, West Point N. Y.

Awarded Award Notice Posted

Solicitation number
W912DS-17-B-0005
Agency
ENDIST New York US Army Corps of Engineers, Department of Defense
Awarded
to J Kokolakis Contracting Inc.
Set-aside
No set-aside

Opportunity facts

Contract number
W912DS-17-C-0011 Federal contract award
NAICS code
236220 Commercial and Institutional Building Construction
PSC
Not on record
Place of performance
West Point, New York, United States

Notice details come from SAM.gov. Updated .

Notice text

2 versions

Update #2 · Latest ·

Added: May 23, 2017 1:15 pm Modified: Jul 24, 2017 5:04 pmTrack Changes

The New York District, U.S. Army Corps of Engineers (USACE) is preparing plans and specifications for the renovation of the entire Eisenhower Barracks, a 235,040 square foot, multi-story cadet barracks building at the U.S. Military Academy, West Point, NY with a current capacity of 673 Cadets with 320 rooms. The scope of the work entails the repair of the entire Eisenhower Barracks (Building 745C).  Building repairs will address the interior configuration, life/safety, energy conservation, and utility systems which can no longer accommodate modern living conditions.


 


Architecture repairs will address space deficiencies for programmed functions such as: laundry, storage, day rooms, study rooms, TAC offices, barrack rooms, and latrines to address gender equality for both male and female Cadets.  Interior repairs will address failing condition of walls, floors, ceilings and stairwells.  Building exterior and envelope repairs include the restoration of water infiltration systems, structural roof systems, insulation and waterproofing, windows, rooftop equipment screening, and exterior masonry and limestone.


 


Mechanical/Electrical/Plumbing (MEP) repairs will be made to fire suppression and water supply systems, fire alarm and mass notification system, fire detection/protection/monitoring/controls, heating and ventilation systems, plumbing systems, electrical systems, telecommunication and cabling systems, closed circuit television (CCTV), alarm and card access systems, public address systems, time clock systems, cable television systems, and distributed antenna systems (DAS).


 


Repairs will include the abatement of all hazardous material that is known.


The completed facility will accommodate 612 Cadets and 16 Tactical Officers and Tactical NCOs for a total of 306 cadet rooms and 8 TAC/TAC NCO rooms.  Repairs will comply with EPAct 2005, EISA 2007, Executive Orders (EO) 13423 and 13514, and other current policies and directives on energy and water conservation.  This project will achieve GBCI level certification at the LEED-NC/MR silver level and will follow the guidance detailed in the Sustainable Design and Development Policy.  


 


This procurement is being solicited under 100% Full and Open Competition. The apparent low bidder will be required to submit a subcontracting plan upon request by the Contracting Officer. The North American Industry Classification System (NAICS) code is 236220. The business size standard is $36,500,000.


 


The anticipated Magnitude of Construction is between $25,000,000.00 and $100,000,000.00.


 


Bids will be submitted to the U.S. Army Corps of Engineers, Contracting Division, Room 1843, 26 Federal Plaza, New York, NY 10278.


 


All questions must be submitted in writing via email to Orlando Nieves at Orlando.Nieves@usace.army.mil and nydcontracting@usace.army.mil.


 


The small business subcontracting goals for USACE New York District are as follows, and will not accept goals that are lower: Small Business 34.5%, Small Disadvantaged Business 5.0%, Women-Owned Small Business 5.0%, HubZone Small Business 3.0%, Veteran Owned Small Business and Service Disabled Veteran Owned Small Business 3.0%. A subcontracting plan reflecting goals less than indicated, shall provide, as part of the subcontracting plan submission, those extenuating circumstances of why the goal cannot be met. You may contact the District, Deputy of Small Business or your local SBA for assistance. A contract will not be awarded until the Contracting Officer has determined that the subcontracting plan provides maximum practicable opportunities for Small Business, Small Disadvantaged Business, Veteran-Owned Small Business, Service Disabled Veteran-Owned Small Business, HubZone Small Business and Women-Owned Small Business program concerns to participate in contract performance.


 


The media selected for issuance of Synopsis/Solicitation and amendments shall solely be at the discretion of the Government; accordingly, the media utilized for this project shall be the internet. Paper copies of this solicitation and amendments, if any, will not be available or issued. In accordance with DFARS 252.204-7007, all vendors who want access to the solicitation must be registered with System for Award Management (SAM), located at https://www.sam.gov/portal/public/SAM/ and Federal Business Opportunity (FedBizOpps), located at http://www.fbo.gov, in order to safeguard acquisition-related information for all Federal Agencies. Interested parties may download and print the solicitation at no charge from the FedBizOpps website http://www.fbo.gov. Some contractor tools are as follows: 1. Register to receive Notification, and 2. Subscribe to the Mailing List for specific solicitations at Federal Business Opportunities (www.fbo.gov) or utilize the Vendor Notification Service in ASFI (https://www.acquisition.army.mil/asfi). FedBizOpps directs vendors to hyperlinks for Federal Business opportunities, such as solicitations, plans, specifications, and amendments. Check www.fbo.gov frequently for information and updates.


 


 Project specification files and drawings are portable document files (PDF). The Office of the Under Secretary of Defense (Acquisition Technology & Logistics (OUSD{AT&L}) A Guide to Collection & Use of Past Performance Information dated 2003 and FAR Part 36 requires the collection and use of past performance information (PPI) in acquiring best-value goods and services. FAR Subpart 36.3 and DFARS Subpart 236.2 mandate the use of Contract Performance Assessment Reporting System (CPARS) by all DoD agencies for construction contracts greater than or equal to $650,000 or more than $10,000 if the contract was terminated for default. CPARS is located at: https://www.cpars.csd.disa.mil.


 


More definitive guidance and instructions will be incorporated in the solicitation and resultant contract.



For further information, contact: Orlando Nieves, Contract Specialist, U.S. Army Corps of Engineers, New York District, 26 Federal Plaza, Room 1843, New York, NY 10278-0090. E-mail: Orlando.Nieves@usace.army.mil and nydcontracting@usace.army.mil


 


This is an unrestricted procurement.


 

Update #1 ·

Added: May 23, 2017 1:15 pm

The New York District, U.S. Army Corps of Engineers (USACE) is preparing plans and specifications for the renovation of the entire Eisenhower Barracks, a 235,040 square foot, multi-story cadet barracks building at the U.S. Military Academy, West Point, NY with a current capacity of 673 Cadets with 320 rooms. The scope of the work entails the repair of the entire Eisenhower Barracks (Building 745C).  Building repairs will address the interior configuration, life/safety, energy conservation, and utility systems which can no longer accommodate modern living conditions.


 


Architecture repairs will address space deficiencies for programmed functions such as: laundry, storage, day rooms, study rooms, TAC offices, barrack rooms, and latrines to address gender equality for both male and female Cadets.  Interior repairs will address failing condition of walls, floors, ceilings and stairwells.  Building exterior and envelope repairs include the restoration of water infiltration systems, structural roof systems, insulation and waterproofing, windows, rooftop equipment screening, and exterior masonry and limestone.


 


Mechanical/Electrical/Plumbing (MEP) repairs will be made to fire suppression and water supply systems, fire alarm and mass notification system, fire detection/protection/monitoring/controls, heating and ventilation systems, plumbing systems, electrical systems, telecommunication and cabling systems, closed circuit television (CCTV), alarm and card access systems, public address systems, time clock systems, cable television systems, and distributed antenna systems (DAS).


 


Repairs will include the abatement of all hazardous material that is known.


The completed facility will accommodate 612 Cadets and 16 Tactical Officers and Tactical NCOs for a total of 306 cadet rooms and 8 TAC/TAC NCO rooms.  Repairs will comply with EPAct 2005, EISA 2007, Executive Orders (EO) 13423 and 13514, and other current policies and directives on energy and water conservation.  This project will achieve GBCI level certification at the LEED-NC/MR silver level and will follow the guidance detailed in the Sustainable Design and Development Policy.  


 


This procurement is being solicited under 100% Full and Open Competition. The apparent low bidder will be required to submit a subcontracting plan upon request by the Contracting Officer. The North American Industry Classification System (NAICS) code is 236220. The business size standard is $36,500,000.


 


The anticipated Magnitude of Construction is between $25,000,000.00 and $100,000,000.00.


 


Bids will be submitted to the U.S. Army Corps of Engineers, Contracting Division, Room 1843, 26 Federal Plaza, New York, NY 10278.


 


All questions must be submitted in writing via email to Orlando Nieves at Orlando.Nieves@usace.army.mil and nydcontracting@usace.army.mil.


 


The small business subcontracting goals for USACE New York District are as follows, and will not accept goals that are lower: Small Business 34.5%, Small Disadvantaged Business 5.0%, Women-Owned Small Business 5.0%, HubZone Small Business 3.0%, Veteran Owned Small Business and Service Disabled Veteran Owned Small Business 3.0%. A subcontracting plan reflecting goals less than indicated, shall provide, as part of the subcontracting plan submission, those extenuating circumstances of why the goal cannot be met. You may contact the District, Deputy of Small Business or your local SBA for assistance. A contract will not be awarded until the Contracting Officer has determined that the subcontracting plan provides maximum practicable opportunities for Small Business, Small Disadvantaged Business, Veteran-Owned Small Business, Service Disabled Veteran-Owned Small Business, HubZone Small Business and Women-Owned Small Business program concerns to participate in contract performance.


 


The media selected for issuance of Synopsis/Solicitation and amendments shall solely be at the discretion of the Government; accordingly, the media utilized for this project shall be the internet. Paper copies of this solicitation and amendments, if any, will not be available or issued. In accordance with DFARS 252.204-7007, all vendors who want access to the solicitation must be registered with System for Award Management (SAM), located at https://www.sam.gov/portal/public/SAM/ and Federal Business Opportunity (FedBizOpps), located at http://www.fbo.gov, in order to safeguard acquisition-related information for all Federal Agencies. Interested parties may download and print the solicitation at no charge from the FedBizOpps website http://www.fbo.gov. Some contractor tools are as follows: 1. Register to receive Notification, and 2. Subscribe to the Mailing List for specific solicitations at Federal Business Opportunities (www.fbo.gov) or utilize the Vendor Notification Service in ASFI (https://www.acquisition.army.mil/asfi). FedBizOpps directs vendors to hyperlinks for Federal Business opportunities, such as solicitations, plans, specifications, and amendments. Check www.fbo.gov frequently for information and updates.


 


 Project specification files and drawings are portable document files (PDF). The Office of the Under Secretary of Defense (Acquisition Technology & Logistics (OUSD{AT&L}) A Guide to Collection & Use of Past Performance Information dated 2003 and FAR Part 36 requires the collection and use of past performance information (PPI) in acquiring best-value goods and services. FAR Subpart 36.3 and DFARS Subpart 236.2 mandate the use of Contract Performance Assessment Reporting System (CPARS) by all DoD agencies for construction contracts greater than or equal to $650,000 or more than $10,000 if the contract was terminated for default. CPARS is located at: https://www.cpars.csd.disa.mil.


 


More definitive guidance and instructions will be incorporated in the solicitation and resultant contract.



For further information, contact: Orlando Nieves, Contract Specialist, U.S. Army Corps of Engineers, New York District, 26 Federal Plaza, Room 1843, New York, NY 10278-0090. E-mail: Orlando.Nieves@usace.army.mil and nydcontracting@usace.army.mil


 


This is an unrestricted procurement.


 

Attachments

Files attached to this notice, newest first
File Type Posted
Bid_Abstract.pdf PDF
Amendment_0006.pdf PDF
08_71_00_Final.pdf PDF
Amendment_05_All_Revised_Drawings.pdf PDF
23_00_00_Final.pdf PDF
W912DS-17-B-0005-Amendment_0005.pdf PDF
Amendment_0004.pdf PDF
Site_Vist_Sign-In_Sheet.pdf PDF
Amendment_0003.pdf PDF
Amendment__0002.pdf PDF
Amendment_0001.pdf PDF
W912DS-17-B-0005_Specifications.pdf PDF
Set_3_Eisenhower_Bid_Set_-_Stamped-3.pdf PDF
Set_2_Eisenhower_Bid_Set_-_Stamped-2.pdf PDF
Set_4_Eisenhower_Bid_Set_-_Stamped-4.pdf PDF
Set_5_Eisenhower_Bid_Set_-_Stamped-5.pdf PDF
Set_1_Eisenhower_Bid_Set_-_Stamped-1.pdf PDF
W912DS-17-B-0005.pdf PDF
Show all 18

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity