08_71_00_Final.pdf

PDF 308 KB Posted

Attached to
Eisenhower Barracks, West Point N. Y. Federal contract opportunity
Solicitation number
W912DS-17-B-0005
Issued by
Department of the Army Corps of Engineers Engineering District New York

About this file

08 71 00

View the file

Other files for this federal contract opportunity

Other files attached to Eisenhower Barracks, West Point N. Y., newest first.
File Type Posted
Bid_Abstract.pdf PDF
Amendment_0006.pdf PDF
Amendment_05_All_Revised_Drawings.pdf PDF
23_00_00_Final.pdf PDF
W912DS-17-B-0005-Amendment_0005.pdf PDF
Site_Vist_Sign-In_Sheet.pdf PDF
Amendment_0004.pdf PDF
Amendment_0003.pdf PDF
Amendment__0002.pdf PDF
Amendment_0001.pdf PDF
W912DS-17-B-0005_Specifications.pdf PDF
Set_5_Eisenhower_Bid_Set_-_Stamped-5.pdf PDF
Set_1_Eisenhower_Bid_Set_-_Stamped-1.pdf PDF
W912DS-17-B-0005.pdf PDF
Set_3_Eisenhower_Bid_Set_-_Stamped-3.pdf PDF
Set_2_Eisenhower_Bid_Set_-_Stamped-2.pdf PDF
Set_4_Eisenhower_Bid_Set_-_Stamped-4.pdf PDF
Show all 17

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Repair to Eisenhower Barracks 012111

SECTION 08 71 00

DOOR HARDWARE

02/16

AMENDMENT 05

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM F883 (2013) Padlocks

BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)

ANSI/BHMA A156.1 (2013) Butts and Hinges

ANSI/BHMA A156.13 (2012) Mortise Locks & Latches Series 1000

ANSI/BHMA A156.15 (2015) Release Devices Closer Holder, Electromagnetic and Electromechanical

ANSI/BHMA A156.16 (2013) Auxiliary Hardware

ANSI/BHMA A156.18 (2016) Materials and Finishes

ANSI/BHMA A156.2 (2011) Bored and Preassembled Locks and Latches

ANSI/BHMA A156.21 (2014) Thresholds

ANSI/BHMA A156.22 (2012) Door Gasketing and Edge Seal Systems

ANSI/BHMA A156.25 (2013) Electrified Locking Devices

ANSI/BHMA A156.26 (2012) Continuous Hinges

ANSI/BHMA A156.3 (2014) Exit Devices

ANSI/BHMA A156.31 (2013) Electric Strikes and Frame Mounted Actuators

ANSI/BHMA A156.5 (2014) Cylinder and Input Devices for Locks

ANSI/BHMA A156.6 (2015) Architectural Door Trim

ANSI/BHMA A156.7 (2016) Template Hinge Dimensions

ANSI/BHMA A156.8 (2015) Door Controls - Overhead Stops and Holders

SECTION 08 71 00 Page 1

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 101 (2015; ERTA 2015) Life Safety Code

NFPA 105 (2013) Standard for Installation of Smoke Door Assemblies and Other Opening Protectives

NFPA 252 (2017) Standard Methods of Fire Tests of Door Assemblies

NFPA 70 (2017) National Electrical Code

NFPA 72 (2016) National Fire Alarm and Signaling Code

NFPA 80 (2016) Standard for Fire Doors and Other Opening Protectives

STEEL DOOR INSTITUTE (SDI/DOOR)

SDI/DOOR A250.8 (2003; R2008) Recommended Specifications for Standard Steel Doors and Frames

U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)

36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines

UNDERWRITERS LABORATORIES (UL)

UL 10C (2009) Standard for Positive Pressure Fire Tests of Door Assemblies

UL Bld Mat Dir (2012) Building Materials Directory

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability Notebook, in conformance with Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Hardware Schedule; G, A/E

SD-03 Product Data

Hardware Items; G, A/E

SD-08 Manufacturer's Instructions

SECTION 08 71 00 Page 2

Installation

SD-10 Operation and Maintenance Data

Hardware Schedule Items, Data Package 1; G

SD-11 Closeout Submittals

Key Bitting

1.3 PRODUCT DATA

Indicate fire-ratings at applicable components. Provide documentation of ABA/ADA accessibility compliance of applicable components, as required by 36 CFR 1191 Appendix D - Technical.

1.4 HARDWARE SCHEDULE

Prepare and submit hardware schedule in the following form:

Hardware Item

Quantity Size Reference Publi-cation Type No.

Finish Mfr Name and Catalog No.

Key Control Symbols

UL

Mark (If fire-rated and listed)

BHMA

Finish Desig-nation

In addition, submit hardware schedule data package 1 in accordance with Section 01 78 23 OPERATION AND MAINTENANCE DATA.

1.5 KEY BITTING CHART REQUIREMENTS

1.5.1 Requirements

Submit key bitting charts to the Contracting Officer prior to completion of the work. Include:

a. Complete listing of all keys (e.g. AA1 and AA2).

b. Complete listing of all key cuts (AA1-123456, AA2-123458).

c. Tabulation showing which key fits which door.

d. Copy of floor plan showing doors and door numbers.

e. Listing of 20 percent more key cuts than are presently required in each master system.

1.6 QUALITY ASSURANCE

1.6.1 Hardware Manufacturers and Modifications

Provide, as far as feasible, locks, hinges, and closers of one lock, hinge, or closer manufacturer's make. Modify hardware as necessary to provide features indicated or specified.

SECTION 08 71 00 Page 3

1.6.2 Key Shop Drawings Coordination Meeting

Prior to the submission of the key shop drawing, the Contracting Officer, Contractor, Door Hardware Subcontractor, using Activity and Base Locksmith must meet to discuss and coordinate key requirements for the facility.

1.7 DELIVERY, STORAGE, AND HANDLING

Deliver hardware in original individual containers, complete with necessary appurtenances including fasteners and instructions. Mark each individual container with item number as shown on hardware schedule.

Deliver permanent keys and removable cores to the Contracting Officer, either directly or by certified mail. Deliver construction master keys with the locks.

1.8 PRE INSTALLATION MEETING

Prior to commencement of installation of any doors and frames, the General Contractor shall conduct a pre installation meeting that will include qualified representatives from the door hardware supplier, hollow metal door and frame supplier, wood door supplier, access control system contractor, intrusion detection system contractor, fire alarm system contractor, and the electrical contractor. The General Contractor shall present the Shop Drawings for each door component, hardware component, and the various electronic systems that are inter-related with the door assemblies. The meeting will confirm the specifics of the hardware, electro mechanical hardware, access control devices, intrusion detection devices, and fire alarm controlled devices to be installed at each door, along with the related accessories and power requirements, and the related door and frame preparation. The General Contractor will identify items of overlapping or missing scope and resolve. The meeting will result in a mutual understanding and agreement as to the responsibility of each trade toward achieving functionality of all systems.

PART 2 PRODUCTS

2.1 TEMPLATE HARDWARE

Hardware applied to metal or to prefinished doors must be manufactured using a template. Provide templates to door and frame manufacturers in accordance with ANSI/BHMA A156.7 for template hinges. Coordinate hardware items to prevent interference with other hardware.

2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS

Provide all hardware necessary to meet the requirements of NFPA 72 for door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, NFPA 252 for fire tests of door assemblies, ABA/ADA accessibility requirements, and all other requirements indicated, even if such hardware is not specifically mentioned in paragraph HARDWARE SCHEDULE. Provide Underwriters Laboratories, Inc. labels for such hardware in accordance with UL Bld Mat Dir or equivalent labels in accordance with another testing laboratory approved in writing by the Contracting Officer.

2.3 HARDWARE ITEMS

Clearly and permanently mark with the manufacturer's name or trademark, hinges, pivots, locks, latches, exit devices, bolts and closers where the identifying mark is visible after the item is installed. For closers with

SECTION 08 71 00 Page 4 covers, the name or trademark may be beneath the cover. Coordinate electrified door hardware components with corresponding components specified in Division 28 ELECTRONIC SECURITY SYSTEMS (ESS).

2.3.1 Hinges

Provide in accordance with ANSI/BHMA A156.1 with number of knuckles as specified in Door Hardware Sets Ball bearing hinges may be provided in lieu of anti-friction bearing hinges.

2.3.1.1 Quantity

a. Three hinges: For doors with heights up to 90 inches

b. Four hinges: For doors with heights from 91 to 120 inches.

c. Provide additional hinge at doors with width exceeding 40 inches

2.3.1.2 Size

Size hinge width for door thickness and clearances required.

a. Widths up to 36 inches: 4-1/2 inch standard or heavy weight per Basis of Design.

b. Widths from 37 to 48 inches: 5 inch heavy weight per Basis of Design.

2.3.1.3 Options

a. Non-Removable Pins: Provide set screw in hinge barrel that, when tightened into a groove in hinge pin, prevents removal of pin when door is closed; for all doors.

2.3.2 Continuous Hinges

Where continuous hinges are required, provide in accordance with

ANSI/BHMA A156.26 .

2.3.3 Locks and Latches

2.3.3.1 Mortise Locks and Latches

Provide in accordance with ANSI/BHMA A156.13 , Series 1000, Operational Grade 1, Security Grade 2, certified mortise locksets furnished in the functions per the Basis of Design called out in the Door Hardware Sets.

Locksets to be manufactured with a corrosion resistant, stamped 12 gauge minimum formed steel case and be field-reversible for handing without disassembly of the lock body. Lockset trim (including levers and roses) to be the product of a single manufacturer. Furnish with standard 2 3/4" backset, 3/4" throw anti-friction stainless steel latchbolt Provide roses of mortise locks with screwless shanks and no exposed screws. Bore doors to fit cylinders where required by Basis of Design.

Meet 36 CFR 1191 , NFPA 101 , NFPA 80 , and UL 10C positive pressure. The existing USMA System is equal to Schlage Buy American Act (BAA)/American Recovery and Reinvestment Act(ARRA) certified heavy duty commercial lever type with removable 7 pin, Type L keyway.

SECTION 08 71 00 Page 5

2.3.3.2 Lock and Latch Strikes

Strikes: Provide manufacturer's standard strike with strike box for each latch or lock bolt, with curved lip extended to protect frame, finished to match door hardware set, unless otherwise indicated.

2.3.4 Mechanical Exit Devices

Provide in accordance with ANSI/BHMA A156.3 , Types 1 and 2, Grade 1, certified panic and fire exit hardware devices furnished in the functions required by the Basis of Design in the Door Hardware Sets. Provide adjustable strikes for rim type and vertical rod devices. Provide open back strikes for pairs of doors with vertical rod devices. Provide touch bars in lieu of conventional crossbars and arms as required by the Basis of Design in the Door Hardware Sets. Provide escutcheons not less than 7 by 2-1/4 inch.

2.3.4.1 Non-Rated Doors

At doors not requiring a fire rating, provide devices complying with NFPA 101 and listed and labeled for "Panic Hardware" according to UL305. Provide proper fasteners as required by manufacturer including sex nuts and bolts.

2.3.4.2 Fire Rated Doors

Where exit devices are required on fire rated doors, provide devices complying with NFPA 80 and with UL labeling indicating "Fire Exit Hardware". Provide devices with the proper fasteners for installation as tested and listed by UL. Consult manufacturer’s catalog and template book for specific requirements.

2.3.4.3 Flush End Caps

Provide heavy weight impact resistant flush end caps made of architectural metal in the same finish as the devices as in the Door Hardware Sets.

Plastic end caps will not be acceptable.

2.3.4.4 Rail Sizing

Provide exit device rails factory sized for proper door width application.

2.3.5 Cylinders and Cores

2.3.5.1 General

Cylinder manufacturer to have minimum (10) years experience designing secured master key systems and have on record a published security keying system policy.

2.3.5.2 Source Limitations

Obtain each type of keyed cylinder and keys from the same source manufacturer as locksets and exit devices, unless otherwise indicated.

2.3.5.3 Cylinders

ANSI/BHMA A156.5 . Original manufacturer cylinders complying with the following:

SECTION 08 71 00 Page 6

a. Mortise Type: Threaded cylinders with rings and straight- or clover-type cam.

b. Rim Type: Cylinders with back plate, flat-type vertical or horizontal tailpiece, and raised trim ring.

c. Mortise and rim cylinder collars to be solid and recessed to allow the cylinder face to be flush and be free spinning with matching finishes

2.3.5.4 Permanent Cores

Lock cylinders shall be Best Mortise Cylinder Key system or equal to continue the USMA Garrison's master key system. Interchangeable core locks are to be compatible with existing USMA Garrison's "Best" manufactured locks. Provide Removable Cores with core insert removable by use of a special key, and for use with only the core manufacturer's cylinder and door hardware. Provide removable core (small format) as specified in Door Hardware Sets. Finish face to match lockset

2.3.5.5 Construction Cores

Provide disposable temporary cores to requirements of lockset manufacturer for cylinders that will receive permanent cores by Best. Temporary cores shall be small format 7 pin type as specified in Door Hardware Sets.

2.3.6 Electrified Hardware

Comply with the requirements of NFPA 70 for wiring of electrified hardware.

2.3.6.1 Electromechanical Exit Devices

Electrified Conventional Push Rail Devices (Heavy Duty): Subject to same compliance standards and requirements as mechanical exit devices, electrified devices to be of type and design as required by the Basis of Design in the Door Hardware Sets.

2.3.6.1.1 Electrified Options

As indicated by the Basis of Design in the Door Hardware Sets, provide electrified exit device options including: electric latch retraction, electric dogging, outside door trim control, touchbar monitoring and request-to-exit signaling. Unless otherwise indicated by the Basis of Design, provide electrified exit devices standard as fail secure.

2.3.6.2 Electric Strikes and Frame Mounted Actuators

Provide in accordance with ANSI/BHMA A156.31 , Grade 1. Provide electric strikes and actuators as required to meet operational requirements.

Provide electric strikes that remain secure during power failure. Provide battery backup for continued operation during power failure. Provide strikes and actuators with a minimum opening force of 2300 pounds.

Provide facility interface devices that use direct current (dc) power to energize the solenoids. Provide electric strikes and actuators that incorporate end-of-line resistors to facilitate line supervision by the system. If not incorporated into the electric strike or local controller, provide metal oxide resistors (MOVs) to protect the controller from

SECTION 08 71 00 Page 7 reverse current surges.

2.3.6.2.1 Solenoid

Provide actuating solenoid for strikes and actuators that are rated for continuous duty, cannot dissipate more than 12 Watts and must operate on 12 or 24 Volts dc. Inrush current cannot exceed 1 ampere and the holding current cannot be greater than 500 milliamperes. Actuating solenoid must move from fully secure to fully open positions in less than 500 milliseconds.

2.3.6.2.2 Signal Switches

Provide strikes and actuators with signal switches to indicate to the system when the bolt is not engaged or the strike mechanism is unlocked.

Signal switches must report a forced entry to the system.

2.3.6.2.3 Coordination

Provide electric strikes and actuators of a size, weight and profile compatible with each specified door frame. Field verify installation clearances prior to procurement.

2.3.6.2.4 Mounting Method

Provide electric strikes and actuators suitable for use with single and double doors, with mortise or rim type hardware specified, and for right or left hand mounting as specified. In double door installations, locate the lock in the active leaf and monitor the fixed leaf.

2.3.6.3 Electrified Mortise Locks

Provide in accordance with ANSI/BHMA A156.25 , Grade 1 (Heavy Duty).

Provide electrified mortise locks of type and design as indicated by the Basis of Design in the Door Hardware Sets. Provide facility interface devices that use dc power to energize solenoids. Provide solenoids, resisters, and signal switches in accordance with paragraph ELECTRIC

STRIKES AND FRAME MOUNTED ACTUATORS.

2.3.6.3.1 Electrified Lock Options:

As indicated by the Basis of Design in the Door Hardware Sets, provide electrified options including: outside door lock/unlock trim control, latchbolt and lock/unlock status monitoring, and request-to-exit signaling. Unless otherwise indicated, provide electrified locksets standard as fail secure.

2.3.6.4 Power Transfer Hinges

Provide power transfer hinges with each electrified lock that route power and monitoring signals from the lockset to the door frame. Coordinate power transfer hinges with door frames.

2.3.6.5 Card Readers and Keypad Access Control Hardware

Card Reader/Keypads shall be Hirsch Identive CR-SCM-CCLK so as integrate into the USMA access control system. Provide dc power, power transfer, and wiring as required for each installation. Coordinate installation with work of access control system and intrusion detection system. Coordinate

SECTION 08 71 00 Page 8 access control hardware with corresponding devices and systems specified in Division 28 ELECTRONIC SECURITY SYSTEMS (ESS).

2.3.6.6 Release Devices

In accordance with ANSI/BHMA A156.15 , Grade 1.

2.3.6.6.1 Release Devices

Provide wall and floor mounted Electromagnetic release devices connected to smoke detecting devices.

2.3.7 Lock Trim

Provide cast, forged, or heavy wrought construction and commercial plain design for lock trim.

2.3.7.1 Knobs and Roses

Provide in accordance with ANSI/BHMA A156.2 and ANSI/BHMA A156.13 for knobs, roses, and escutcheons. For unreinforced knobs, roses, and escutcheons, provide a 0.050 inch thickness. For reinforced knobs, roses, and escutcheons, provide an outer shell thickness of 0.035 inch and a combined total thickness of 0.070 inch, except at knob shanks. Provide knob shanks 0.060 inch thick.

2.3.7.2 Lever Handles

Provide lever handles where indicated in the Hardware Schedule. Provide in accordance with ANSI/BHMA A156.3 for mortise locks of lever handles for exit devices. Provide lever handle locks with a breakaway feature (such as a weakened spindle or a shear key) to prevent irreparable damage to the lock when force in excess of that specified in ANSI/BHMA A156.13 is applied to the lever handle. Provide lever handles return to within 1/2 inch of the door face.

2.3.7.3 Texture

Provide knurled or abrasive coated knobs or lever handles for doors which are accessible to blind persons and which lead to dangerous areas.

2.3.8 Keys

Furnish one file key, one duplicate key, and one working key for each key change and for each master and grand master keying system. Furnish one additional working key for each lock of each keyed-alike group. Furnish two additional keys for each sleeping room. Furnish a quantity of key blanks equal to 20 percent of the total number of file keys. Stamp each key with appropriate key control symbol and "U.S. property - do not duplicate." Do not place room number on keys.

2.3.8.1 Construction Keying

Provide construction master keys in quantity as required by project Contractor. Replace construction cores with permanent cores.

2.3.9 Door Bolts

Provide in accordance with ANSI/BHMA A156.16 . Provide dustproof strikes

SECTION 08 71 00 Page 9 for bottom bolts, except at doors having metal thresholds. Provide automatic latching flush bolts in accordance with ANSI/BHMA A156.3 , Type 25.

2.3.10 Closers

2.3.10.1 General

a. Door closers to be from one manufacturer, matching in design and style, with the same type door preparations and templates regardless of application or spring size. Closers to be non-handed with full sized covers including installation and adjusting information on inside of cover.

b. Closers to comply with UL-10C and UBC 7-2 for Positive Pressure Fire Test and be U.L. listed for use of fire rated doors.

c. Comply with manufacturer's written recommendations for sizing of door closers depending on size of door, exposure to weather, and anticipated frequency of use.

d. Provide heavy duty, forged steel closer arms unless otherwise indicated by the Basis of Design in the Door Hardware Sets.

e. Where closers are indicated to have mechanical dead-stop, provide heavy duty arms and brackets with an integral positive stop. Where closers are indicated to have mechanical hold open, provide heavy duty units with an additional built-in mechanical holder assembly designed to hold open against normal wind and traffic conditions. Holder to be manually selectable to on-off position. Where closers are indicated to have a cushion-type stop, provide heavy duty arms and brackets with spring stop mechanism to cushion door when opened to maximum degree.

f. Closers shall not be installed on exterior or corridor side of doors; where possible install closers on door for optimum aesthetics. Provide drop plates or other accessories as required for proper mounting.

2.3.10.2 Surface Mounted Door Closers (Unitrol)

ANSI/BHMA A156.4, Grade 1 surface mounted, heavy duty door closers with complete spring power adjustment, sizes 1 thru 6; and fully operational adjustable according to door size, frequency of use, and opening force.

Closers to be rack and pinion type, one piece cast iron or aluminum alloy body construction, with adjustable backcheck and separate non-critical valves for closing sweep and latch speed control. Provide non-handed units and high impact, non-corrosive plastic covers standard.

2.3.10.3 Identification Marking

Engrave each closer with manufacturer's name or trademark, date of manufacture, and manufacturer's size designation in locations that will be visible after installation.

2.3.11 Overhead Holders

Provide in accordance with ANSI/BHMA A156.8 .

SECTION 08 71 00 Page 10

2.3.12 Door Protection Plates

Provide in accordance with ANSI/BHMA A156.6 .

2.3.12.1 Sizes of Mop and Kick Plates

2 inch less than door width for single doors; 1 inch less than door width for pairs of doors. Provide 10 inch kick plates for flush doors and 1 inch less than height of bottom rail for panel doors. Provide 6 inch mop plates.

2.3.13 Door Stops and Silencers

Provide in accordance with ANSI/BHMA A156.16 . Silencers Type L03011.

Provide three silencers for each single door, two for each pair.

2.3.14 Padlocks

Provide in accordance with ASTM F883.

2.3.15 Thresholds

Provide in accordance with ANSI/BHMA A156.21 . Use J35100, with vinyl or silicone rubber insert in face of stop, for exterior doors opening out, unless specified otherwise.

2.3.16 Weatherstripping Gasketing

2.3.16.1 General

Weatherstripping, smoke seals, and other gasketing are to be of type and design as required by the Basis of Design in the Door Hardware Sets.

Provide continuous weatherstrip gasketing on exterior doors and provide smoke gasketing on interior doors where indicated. At exterior applications provide non-corrosive fasteners.

2.3.16.2 Smoke Seals

ANSI/BHMA A156.22 . Provide products complying with NFPA 105 that are listed and labeled by a testing and inspecting agency acceptable to USMA, at smoke controlled openings shown on drawings, based on testing according to UL 1784, Categories H and J. Provide smoke gasketing per Basis of Design in Hardware Set Schedule. Meet NFPA 252 , NFPA 80 , and UL 10C positive pressure.

2.3.16.3 Replaceable Seal Strips

Provide only those products where resilient or flexible seal strips are easily replaceable and readily available from stocks maintained by manufacturer.

2.3.17 Rain Drips

Provide in accordance with ANSI/BHMA A156.22 . Provide in type and design as required by the Basis of Design in the Door Hardware Sets.

Set drips in sealant and fasten with stainless steel screws.

SECTION 08 71 00 Page 11

2.3.17.1 Door Rain Drips

Approximately 1-1/2 inch high by 5/8 inch projection. Align bottom with bottom edge of door.

2.3.17.2 Overhead Rain Drips

Approximately 1-1/2 inch high by 2-1/2 inch projection. Align bottom with door frame rabbet.

2.3.18 Auxiliary Hardware (Other than locks)

Provide in accordance with ANSI/BHMA A156.16 , Grade 1.

2.3.19 Special Tools

Provide special tools, such as spanner and socket wrenches and dogging keys, as required to service and adjust hardware items.

2.4 FASTENERS

Provide fasteners of type, quality, size, and quantity appropriate to the specific application. Fastener finish to match hardware. Provide stainless steel or nonferrous metal fasteners in locations exposed to weather. Verify metals in contact with one another are compatible and will avoid galvanic corrosion when exposed to weather.

2.5 FINISHES

ANSI/BHMA A156.18 . Provide hardware in finishes shown in Door Hardware Sets.

2.6 KEY CABINET AND CONTROL SYSTEM

Provide in accordance with ANSI/BHMA A156.5 , Type required to yield a capacity (number of hooks) 50 percent greater than the number of key changes used for door locks.

PART 3 EXECUTION

3.1 INSTALLATION

Provide hardware in accordance with manufacturers' printed installation instructions. Fasten hardware to wood surfaces with full-threaded wood screws or sheet metal screws. Provide machine screws set in expansion shields for fastening hardware to solid concrete and masonry surfaces.

Provide toggle bolts where required for fastening to hollow core construction. Provide through bolts where necessary for satisfactory installation.

3.1.1 Weatherstripping Installation

Provide full contact, weathertight seals that allow operation of doors without binding the weatherstripping.

3.1.2 Threshold Installation

Extend thresholds the full width of the opening and notch end for jamb stops. Set thresholds in a full bed of sealant and anchor to floor with

SECTION 08 71 00 Page 12 cadmium-plated, countersunk, steel screws in expansion sleeves.

3.2 FIRE DOORS AND EXIT DOORS

Provide hardware in accordance with NFPA 72 for door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, and NFPA 252 for fire tests of door assemblies.

3.3 HARDWARE LOCATIONS

Provide in accordance with SDI/DOOR A250.8 , unless indicated or specified otherwise.

a. Kick Plates: Push side of single-acting doors. Both sides of double-acting doors.

b. Mop Plates: Bottom flush with bottom of door.

3.4 KEY CABINET AND CONTROL SYSTEM

Locate where directed by the Contracting Officer. Tag one set of file keys and one set of duplicate keys. Place other keys in appropriately marked envelopes, or tag each key. Provide complete instructions for setup and use of key control system. On tags and envelopes, indicate door and room numbers or master or grand master key.

3.5 FIELD QUALITY CONTROL

After installation, protect hardware from paint, stains, blemishes, and other damage until acceptance of work. Submit notice of testing 15 days before scheduled, so that testing can be witnessed by the Contracting Officer. Adjust hinges, locks, latches, bolts, holders, closers, and other items to operate properly. Demonstrate that permanent keys operate respective locks, and give keys to the Contracting Officer. Correct, repair, and finish, errors in cutting and fitting and damage to adjoining work.

3.6 HARDWARE SETS

The DOOR HARDWARE SET SCHEDULE that follows represents the design intent of the government. These sets are a guideline only and should not be considered a detailed hardware schedule. Discrepancies, conflicting hardware and missing items should be brought to the attention of the Contracting Officer with corrections made prior to the bidding process.

Necessary items not included in a hardware set should be scheduled with the appropriate additional hardware required for proper application and functionality. Not all manufacturer's listed below are used in the Basis of Design

Manufacturer’s Abbreviations:

1. AB - ABH Manufacturing Inc.

2. BE - Best Access Systems

3. BY - By Others

4. NA - National Guard

5. PR - Precision

6. SD - Stanley Door Closers

7. SE - Security Door Controls, Inc.

8. ST - Stanley

SECTION 08 71 00 Page 13

9. HES - Hanchett Entry Systems 10.TRI - Trimco

-- End of Section --

SECTION 08 71 00 Page 14

REPAIRS TO EISENHOWER BARRACKS

USMA West Point, New York

2.5 pair butts BB1168 5" x 4.5" US10 HA

1 closer 690 STA

1 exit device rim (F14) FL2114 4' 4914A 612 STA

1 strike S300 STA gasketing 232" S88D PE

1 doorstop 466 RO

1 kickplate 194S 10" X 42" CSK US10 HA

1.5 pair butts BB1168 4.5" x 4.5" US10 HA

1 closer 690 STA

1 exit device rim (F14) FL2114 4914A 612 STA

1 strike S300 STA gasketing 200" S88D PE

1 doorstop 466 RO

1 kickplate 194S 10" x 34" CSK US10 HA

1.5 pair butts BB1168 5" x 4.5" US10 HA

1 closer 690 STA

1 exit device rim (F14) FL2114 4914A 612 STA

1 strike S300 STA gasketing 208" S88D PE

1 doorstop 466 RO

1 kickplate 194S 10" x 46" CSK US10 HA

Set 1.0A - Stairwell 2 hour Wide and Tall

Doors: E020B, E159A, E159B, E171A, E171B, E172B

QDC115 (push side)

Set 1.0C - Stairwell 2 hour Wide and Short

Doors: E150A, E150B, E172C, E257A, E257B, E269A, E269B, E280A, E280B, E282, E360A, E360B, E372A, E372B, E383A, E384B, E460A, E460B, E472A, E472B, E483A, E483B, E560A, E560B, E572A, E572B, E583A, E583B, E660A, E660B, E672A, E672B, E683A, E683B

QDC115 (push side)

Set 1.0B - Stairwell 2 hour Short

QDC115 (push side)

Doors: E003, E011, E017, E150C, E159C, E175, E178A, E384B, E385, E485, E585, E685

SECTION 08 71 00 Page 15

Amdt. 05

Wolfesm Typewritten Text

Wolfesm Typewritten Text

Wolfesm Typewritten Text

Wolfesm Typewritten Text

1.5 pair butts BB1168 5" x 4.5" US10 HA

1 privacy set (F76) 9K30L 15C STK 612 STA

1 doorstop 466 RO smoke seal 200" S88D PE

1 kickplate 194S 10" x 34" 4BE CSK 612 HA

1 mop plate 194S 6" x 35" 4BE CSK 612 HA

1.5 pair butts BB1168 5" x 4.5" US10 HA

1 closer 690 STA

1 privacy set (F76) 9K30L 15C STK 612 STA

1 doorstop 466 RO

3 silencers 608 Gray RO

1 kickplate 194S 10" x 34" 4BE CSK 612 HA

1 mop plate 194S 6" x 35" 4BE CSK 612 HA

2.0 pair butts BB1168 5" x 4.5" US10 HA

1 closer 690 STA

1 passage set (F75) 9K30N 15C STK 612 STA

1 doorstop 466 RO smoke seal 224" S88D PE

1 kickplate 194S 10" x 34" 4BE CSK 612 HA

1 mop plate 194S 6" x 35" 4BE CSK 612 HA

Set 2.1A- Restroom Smoke

Doors: E147, E148, E180, E283

QDC115 (pull side)

Set 2.1B- Restroom

Doors: E006, E007, E143C, E146

QDC115 (pull side)

Set 2.2- Restroom Smoke Tall

QDC115 (pull side)

Doors: E152A, E152B, E157A, E157B, E165A, E165B, E166A, E166B

SECTION 08 71 00 Page 16

Amdt. 05

1 passage set (F75) 9K30N 15C STK 612 STA

1 doorstop 466 RO smoke seal 200" S88D PE

1 kickplate 194S 10" x 34" 4BE CSK 612 HA

1 mop plate 194S 6" x 35" 4BE CSK 612 HA

1.5 pair butts BB1168 4.5" x 4.5" US10 HA

1 closer QDC111 (pull side) 690 STA

1 passage set (F75) 9K30N 15C S3 612 STA

1 doorstop 466 RO smoke seal 200" S88D PE

1 kickplate 194S 10" x 34" 4BE CSK 612 HA

1 mop plate 194S 6" x 35" 4BE CSK 612 HA

Set 2.3- Restroom Smoke

Doors: E260A, E260B, E261A, E261B, E266A, E266B, E270A, E270B, E274A, E274B, E275A, E275B, E363A, E363B, E364A, E364B, E369A, E369B, E373A, E373B, E377A, E377B, E378A, E378B, E463A, E463B, E464A, E464B, E469A, E469B, E473A, E473B, E477A, E477B, E478A, E478B, E563A, E563B, E564A, E564B, E569A, E569B, E573A, E573B, E577A, E577B, E578A, E578B, E663A, E663B, E664A, E664B, E669A, E669B, E673A, E673B, E677A, E677B, E678A, E678B

QDC115 (pull side)

Set 3.0 - Laundry Smoke Short

Doors: E344, E444, E544, E644

SECTION 08 71 00 Page 17

Door: E163A, E163B

1 pair butts BB1168 4.5" x 4.5" US10 HA

1 electric hinge BB1168 4.5" x 4.5" ETW-8 US10 HA

1 closer QDC116 (push side) 690 STA

1 electrified mortise lockset (F07) 45HW7DEU 15R DS RQE 612 STA

1 strike S982 612 STA

1 construction core 1CC STA

1 SFIC core 612

1 card reader by access control

1 power supply (number of units as required) by access control

1 doorstop 466 RO smoke seal 208" S88D PE

1 kickplate 194S 10" x 34" 4BE CSK 612 HA

1 mop plate 194S 6" x 35" 4BE CSK 612 HA

1 pair butts BB1168 4.5" x 4.5" US10 HA

1 electric hinge BB1168 4.5" x 4.5" ETW-8 US10 HA

1 closer QDC116 (push side) 690 STA

1 electrified mortise lockset (F07) 45HW7DEU 15R DS RQE 612 STA

1 strike S982 612 STA

1 construction core 1CC STA

1 SFIC core 612

1 card reader by access control

1 power supply (number of units as required) by access control

1 doorstop 466 RO smoke seal 200" S88D PE

1 kickplate 194S 10" x 34" 4BE CSK 612 HA

1 mop plate 194S 6" x 35" 4BE CSK 612 HA

Set 4.0B - Storage Smoke Secure Short

1C Series - match existing system

Door: E144, E288, E289, E386, E389, E390, E486, E489, E490, E586, E589, E590, E686, E689, E690

Set 4.0A - Storage Smoke Secure

1C Series - match existing system

SECTION 08 71 00 Page 18

1 electric hinge BB1168 5" x 4.5" ETW-8 US10 HA

1 closer QDC118 (pull side) 690 STA

1 electrified mortise lockset (F07) 45HW7DEU 15R DS RQE 612 STA

1 strike S982 612 STA

1 construction core 1CC STA

1 SFIC core 612

1 card reader by access control

1 power supply (number of units as required) by access control

1 kickplate 194S 10" x 46" 4BE CSK 612 HA

3 silencers 608 Gray RO

1 pair butts BB1168 5" x 4.5" US10 HA

1 electric hinge BB1168 5" x 4.5" ETW-8 US10 HA

1 closer QDC115 (pull side) 690 STA

1 electrified mortise lockset (F07) 45HW7DEU 15R DS RQE 612 STA

1 strike S982 612 STA

1 construction core 1CC STA

1 SFIC core 612

1 card reader by access control

1 power supply (number of units as required) by access control

1 doorstop 466 RO gasketing 200" S88D PE

1 kickplate 194S 10" x 46" 4BE CSK 612 HA

Set 4.1 - Storage Secure Wide

Set 4.2- Storage 1 Hour Secure Wide

1C Series - match existing system

Doors: E020A, E021, E032B

Doors: E013, E015 E017A, E023, E029A, E029B, E029C, E029D, E032A, E032C

1C Series - match existing

SECTION 08 71 00 Page 19

3.0 pair butts BB1168 4.5" x 4.5" NRP US10 HA

1 mortise lockset (F07) 45H7D 15R 612 STA

1 strike S984 612 STA

1 construction core 1CC STA

1 SFIC core 612

1 set mortised flushbolts at inactive leaf

2945 630 RO

1 dustproof floor strike 570 RO

2 kickplate 194S 10" x 46" 4BE CSK 612 HA

6 silencers 608 Gray RO

Door: E030B

2.5 pair butts BB1168 4.5" x 4.5" NRP US10 HA

1 electric hinge BB1168 4.5" x 4.5" ETW-8 US10 HA

1 closer QDC116 (push side) 690 STA

1 electrified mortise lockset (F07) 45HW7DEU 15R DS RQE 612 STA

1 strike S982 612 STA

1 construction core 1CC STA

1 SFIC core 612

1 card reader by access control

1 power supply (number of units as required) by access control

1 set mortised flushbolts at inactive leaf

2945 630 RO

1 dustproof floor strike 570 RO

2 kickplate 194S 10"x 34" CSK US10 STA

6 silencers 608 Gray RO

Set 4.3- Storage Double

Doors: E346, E446, E546, E646

Set 4.4 - Gaming Secure Double

1C Series - match existing system

1C Series - match existing

SECTION 08 71 00 Page 20

1.5 pair butts BB1168 5" x 4.5" NRP US10 HA

1 electric hinge BB1168 5" x 4.5" ETW-8 US10 HA

1 closer QDC118 (push side) 690 STA

1 electrified mortise lockset (F07) 45HW7DEU 15R DS RQE 612 STA

1 strike S982 612 STA

1 construction core 1CC STA

1 SFIC core 612

1 card reader by access control

1 power supply (number of units as required) by access control

1 kickplate 194S 10"x 46" CSK US10 STA

4 silencers 307D Gray HA

Doors: E018, E019A

2.5 pair butts BB1168 4.5" x 4.5" NRP US10 HA

1 electric hinge BB1168 4.5" x 4.5" ETW-8 US10 HA

2 closer 690 STA

1 coordinator 2600 series x wear plates RO

1 astragal 357SP x S88 PE

1 electrified mortise lockset (F07) 45HW7DEU 15R DS RQE 612 STA

1 strike S984 612 STA

1 construction core 1CC STA

1 SFIC core 612

1 card reader by access control

1 power supply (number of units as required) by access control

1 set mortised flushbolts at inactive leaf

2945 630 RO

1 dustproof floor strike 570 RO

2 kickplate 194S 10"x 34" CSK US10 STA gasketing 240" S88D PE

1C Series - match existing system

Set 4.6 - Storage 1 hour Secure Double

Set 4.5 - Storage/Gaming Secure Wide

Door: E001A, E001B, E004A, E004B, E012A, E012B, E014A, E014B, E030C, E030A

1C Series - match existing system

QDC118 (pull side)

SECTION 08 71 00 Page 21

1.5 pair butts BB1168 4.5" x 4.5" NRP US10 HA

1 mortise lockset (F07) 45H7D 15R 612 STA

1 strike S982 612 STA

1 construction core 1CC STA

1 SFIC permanent core 612

1 kickplate 194S 10"x 34" CSK US10 STA

1 mop plate 194S 6" x 35" 4BE CSK 612 HA

3 silencers 307D Gray HA

1.5 pair butts BB1168 4.5" x 4.5" NRP US10 HA

1 closer QDC115 (pull side) 690 STA

1 mortise lockset (F04) 45H7A 15R 612 STA

1 strike S982 612 STA

1 construction core 1CC STA

1 SFIC permanent core 612

1 doorstop 466 RO

1 kickplate 194S 10"x 34" CSK US10 STA

3 silencers 608 Gray RO

QDC117 (push side)

Set 4.7 - Storage

1C Series - match existing system

1C Series - match existing system

Set 5.1 - Office

Doors: E026, E027, E173, E179, E183A, E183B

Doors: E184, E183C, E185

SECTION 08 71 00 Page 22

1.0 pair butts BB1168 4.5" x 4.5" NRP US10 HA

1 electric hinge BB1168 4.5" x 4.5" ETW-8 US10 HA

1 closer QDC116 690 STA

1 electrified mortise lockset (F07) 45HW7DEU 15R DS RQE 612 STA

1 strike S982 612 STA

1 construction core 1CC STA

1 SFIC permanent core 612

1 card reader by access control

1 power supply (number of units as required) by access control

1 kickplate 194S 10"x 34" CSK US10 STA

1 mop plate 194S 6" x 35" 4BE CSK 612 HA smoke seals 208" S88D PE

BB1168 4.5" x 4.5" NRP US10 HA

1 electric hinge BB1168 4.5" x 4.5" ETW-8 US10 HA

1 closer QDC116 690 STA

1 mortise lockset (F04) 45H7A 15R 612 STA

1 strike S982 612 STA

1 construction core 1CC STA

1 SFIC permanent core 612

1 kickplate 194S 10"x34" CSK US10 STA

1 mop plate 194S 6" x 35" 4BE CSK 612 HA smoke seals 200" S88D PE

Set 5.2 - Office Smoke Secure

Doors: E151A, E151B

1C Series - match existing system

Set 5.3A- Office Smoke Short

Doors: E285, E286

1C Series - match existing

SECTION 08 71 00 Page 23

1 closer QDC116 690 STA

1 electrified mortise lockset (F07) 45HW7DEU 15R DS RQE 612 STA

1 strike S982 612 STA

1 construction core 1CC STA

1 SFIC permanent core 612

1 card reader by access control

1 power supply (number of units as required) by access control

1 kickplate 194S 10"x 34" CSK US10 STA

1 mop plate 194S 6" x 35" 4BE CSK 612 HA smoke seals 200" S88D PE

3 pair butts T4A3786 US10 MK

2 closer 690 STA

2 astragal 18041 PE

2 electrified exit devices (30") exposed vertical rod

612 STA

2 top strikes S300 STA

2 dustproof floor strikes 570 RO

1 card reader by access control

1 power supply (number of units as required) by access control smoke seals 204" S88D PE

2 kickplates 194S 10"x 46" CSK US10 STA

1 threshold 2005AV 304/4 PE

Set 5.3B - Office Smoke Secure Short

Set 5.3C - Office Smoke Secure Double

Doors: E145

Doors: E175, E176, E177, E284, E287

1C Series - match existing system

QDC115 (push side)

E FSE TDS 2203 CD 4903A RQE DS

SECTION 08 71 00 Page 24

Doors: E009C

1 closer QDC117 (pull side) 690 STA

1 exit device rim (F14) 2114 4914A 612 STA

1 strike S300 612 STA

1 kickplate 194S 10"x 46" CSK US10 STA

1 sweep 345 ANB PE weatherstrip 208" 2891AS PE

1 threshold 252 x 3SSFG 304/4 PE

Doors: E009D

3.0 pair butts BB1168 5" x 4.5" NRP US10 HA

2 closer QDC117 (pull side) 690 STA

1 exit device rim (F14) 2114 4914A 612 STA

1 strike S300 612 STA

2 kickplate 194S 10"x 46" CSK US10 STA

2 sweep 345 ANB PE

1 set mortised flushbolts at inactive leaf

2845 630 RO

1 dustproof floor strike 570 RO weatherstrip 244" 2891AS PE

1 threshold 252 x 3SSFG 304/4 PE

Set 6.0B - Electrical Exterior Double

Set 6.0A - Electrical Exterior

SECTION 08 71 00 Page 25

Doors: E009A

2.5 pair butts BB1168 5" x 4.5" NRP US10 HA

1 electric hinge BB1168 5" x 4.5" ETW-8 US10 HA

2 closer QDC117 (push side) 690 STA

1 electrified exit device rim (F09) E FSE TDS 2103 4903A DS RQE 612 STA

1 strike S300 612 STA

1 construction core 1CC STA

1 SFIC core 612

1 card reader by access control

1 power supply (number of units as required) by access control gasketing 244" S88D PE

1 kickplate 194S 10"x 46" CSK US10 STA

1.0 pair butts BB1168 4.5" x 4.5" NRP US10 HA

1 electric hinge BB1168 4.5" x 4.5" ETW-8 US10 HA

1 closer QDC117 (push side) 690 STA

1 electrified mortise lockset (F07) 45HW7DEU 15R DS RQE 612 STA

1 strike S300 612 STA

1 construction core 1CC STA

1 SFIC core 612

1 card reader by access control

1 power supply (number of units as required) by access control smoke seals 200" S88D PE

1 kickplate 194S 10"x 46" CSK US10 STA

1 mop plate 194S 6" x 35" 4BE CSK 612 HA

1C Series - match existing system

Set 6.2 - Electrical Smoke Secure Short

1C Series - match existing system

Doors: E158A, E158B, E267A, E267B, E370A, E370B, E470A, E470B, E570A, E570B, E670A, E670B

Set 6.1 - Electrical 1 hour Secure Double

SECTION 08 71 00 Page 26

Doors: E009B

1 electric hinge BB1168 5" x 4.5" ETW-8 US10 HA

1 closer QDC117 (push side) 690 STA

1 electrified exit device rim (F09) E FSE TDS FL 2103 4903A DS RQE 612 STA

1 strike S300 612 STA

1 construction core 1CC STA

1 SFIC core 612

1 card reader by access control

1 power supply (number of units as required) by access control

1 kickplate 194S 10"x 46" CSK US10 STA gasketing 216" S88D PE

Doors: E002, E028A, E028B

2.5 pair butts BB1168 4.5" x 4.5" NRP US10 HA

1 electric hinge BB1168 4.5" x 4.5" ETW-8 US10 HA

2 closers QDC117 (push side) 690 STA

1 coordinator 2600 series x wear plates RO

1 astragal 357SP x S88 PE

1 electrified mortise lockset (F07) 45HW7DEU 15R DS RQE 612 STA

1 strike S458 STA

1 construction core 1CC STA

1 SFIC core 612

1 card reader by access control

1 power supply (number of units as required) by access control

1 set mortised flushbolts at inactive leaf

2845 630 RO

1 dustproof floor strike 570 RO gasketing 244" S88D PE

2 kickplates 194S 10"x 46" CSK US10 STA

Set 8.0 - Mechanical 1 hour Secure Double

1C Series - match existing system

Set 6.3 - Electrical 1 hour Secure Wide

1C Series - match existing

SECTION 08 71 00 Page 27

Door: E031A, E031B

1 closer 690 STA

1 mortise lockset(F07) 45H7D 15R 612 STA

1 strike S982 STA

1 construction core 1CC STA

1 SFIC permanent core 612

1 kickplate 194S 10"x 46" CSK US10 STA

3 silencers 608 Gray RO

Doors: E024, E025, E030D

1.5 pair butts BB1168 4.5" x 4.5" NRP US10 HA

1 closer 690 STA

1 mortise lockset (F07) 612 STA

1 strike S982 STA

1 construction core 1CC STA

1 SFIC permanent core 612

1 doorstop 466 RO

1 kickplate 194S 10" x 34" 4BE CSK 612 HA

1 mop plate 194S 6" x 35" 4BE CSK 612 HA

3 silencers 608 Gray RO

QDC115 (pull side)

1C Series - match existing system

Set 8.1 - Mechanical

QDC115 (push side)

1C Series - match existing system

Set 9.0 - Janitorial

45H7D 15R

SECTION 08 71 00 Page 28

Doors: E169

1 closer at D142 690 STA

1 mortise lockset(F07) 612 STA

1 strike S982 STA

1 construction core 1CC STA

1 SFIC permanent core 612 smoke seals 208" S88D PE

1 doorstop 466 RO

1 kickplate 194S 10" x 34" 4BE CSK 612 HA

1 mop plate 194S 6" x 35" 4BE CSK 612 HA

1.5 pair butts BB1168 4.5" x 4.5" NRP US10 HA

1 closer 690 STA

1 mortise lockset(F07) 612 STA

1 strike S982 STA

1 construction core 1CC STA

1 SFIC permanent core 612 smoke seals 200" S88D PE

1 kickplate 194S 10" x 34" 4BE CSK 612 HA

1 mop plate 194S 6" x 35" 4BE CSK 612 HA

Set 9.1 - Janitorial Smoke

QDC115 (push side)

Doors: E256, E268, E279, E359, E371, E382, E459, E471, E482, E559, E571, E582, E659, E671, E682

Set 9.2 - Janitorial Smoke Short

QDC117 (push side)

45H7D 15R

45H7D 15R

1C Series - match existing system

1C Series - match existing

SECTION 08 71 00 Page 29

Doors: E010, E016

1 electric hinge BB1168 5" x 4.5" ETW-8 US10 HA

1 closer QDC117 (push side) 690 STA

1 electrified mortise lockset (F07) 45HW7DEU 15R DS RQE 612 STA

1 strike S982 STA

1 construction core 1CC STA

1 SFIC core 612

1 card reader by access control

1 power supply (number of units as required) by access control

1 kickplate 194S 10"x 46" CSK US10 STA

3 silencers 80 Gray RO

Door: E155, E170

1.5 pair butts BB1168 4.5" x 4.5" NRP US10 HA

1 electric hinge BB1168 4.5" x 4.5" ETW-8 US10 HA

1 closer QDC117 (push side) 690 STA

1 electrified mortise lockset (F07) 45HW7DEU 15R DS RQE 612 STA

1 strike S982 STA

1 construction core 1CC STA

1 SFIC core 612

1 card reader by access control

1 power supply (number of units as required) by access control smoke seals 224" S88D PE

1 kickplate 194S 10"x 46" CSK 612 RO

Set 10.0 - Telecom 1 hour Secure Wide

1C Series - match existing system

Set 10.1 - Telecom Smoke Secure Tall

1C Series - match existing

SECTION 08 71 00 Page 30

1 closer QDC117 (push side) 690 STA

1 electrified mortise lockset (F07) 45HW7DEU 15R DS RQE 612 STA

1 strike S982 STA

1 construction core 1CC STA

1 SFIC core 612

1 card reader by access control

1 power supply (number of units as required) by access control smoke seals 200" S88D PE

1 kickplate 194S 10"x 46" CSK 612 RO

2 pair butts BB1168 4.5" x 4.5" NRP US10 HA

1 closer 690 STA

1 mortise lockset(F07)

612 STA

1 construction core 1CC STA

1 SFIC permanent core 612

1 electric strike HES 4500C 612 HES

1 card reader by access control

1 power supply (number of units as required) by access control

1 doorstop 466 RO smoke seals 224" S773D PE

1 kickplate 194S 10"x 46" CSK 612 RO

1 electric magnetic hold open

(mount in cabinet kick space)

EM 508 24120 689 DO

1C Series - match existing system

Set 11.0 - TAC and Cadet Smoke Tall

Door: E264, E278, E367, E381, E467, E481, E567, E581, E667, E681

Set 10.2 - Telecom Smoke Secure Short

1C Series - match existing system

Doors: E106, E107, E108, E109, E110, E111, E112, E113, E114, E116, E117, E118, E119, E120, E121, E122, E123, E124, E126, E127, E128, E129, E130, E131, E132, E133, E134, E135, E136, E137, E138, E138A, E139, E139A, E140, E140A, E141, E141A, E142, E143A, E143B

45H7D 15R

QDC115 (pull side)

SECTION 08 71 00 Page 31

1 mortise lockset(F07) 612 STA

1 construction core 1CC STA

1 SFIC permanent core 612

1 electric strike HES 4500C 612 HES

1 card reader by access control

1 power supply (number of units as required) by access control

1 doorstop 466 RO smoke seals 200" S773D PE

1 kickplate 194S 10"x 46" CSK 612 RO

1 electric magnetic hold open

(mount in cabinet kick space)

EM 508 24120 689 DO

QDC115 (push side)

1C Series - match existing system

Doors: E101, E102, E103, E104, E201, E202, E203, E204, E205, E206, E207, E208, E209, E210, E211, E212, E213, E214, E215, E216, E217, E218, E219, E220, E221, E222, E223, E224, E225, E226, E227, E228, E229, E230, E231, E232, E233, E234, E235, E236, E237, E238. E239, E240, E241, E242, E243, E244, E245. E246, E247, E248, E249, E250, E251, E252, E253, E254, E301, E302, E303, E304, E305, E306, E307, E308, E309, E310, E311, E312, E313, E314, E315, E316, E317, E318, E319, E320, E321, E322, E323, E324, E325, E326, E327, E328, E329, E330, E331, E332, E333, E334, E335, E336, E337, E338, E339, E340, E341, E342, E343, E345, E347, E348, E349. E350, E351, E352. E353, E354, E355, E356, E357, E387, E388, E401, E402, E403, E404, E405, E406, E407, E408, E409, E410, E411, E412, E413, E414, E415, E416, E417, E418, E419, E420, E421, E422, E423, E424, E425, E426, E427, E428, E429, E430, E431, E432, E433, E434, E435, E436, E437, E438, E439, E440, E441, E442, E443, E445, E447, E448, E449. E450, E451, E452. E453, E454, E455, E456, E457, E487, E488, E501, E502, E503, E504, E505, E506, E507, E508, E509, E510, E511, E512, E513, E514, E515, E516, E517, E518, E519, E520, E521, E522, E523, E524, E525, E526, E527, E528, E529, E530, E531, E532, E533, E534, E535, E536, E537, E538, E539, E540, E541, E542, E543, E545, E547, E548, E549, E550, E551. E552, E553, E554, E555, E556, E557, E587, E588, E601, E602, E603, E604, E605, E606, E607, E608, E609, E610, E611, E612, E613, E614, E615, E616, E617, E618, E619, E620, E621, E622, E623, E624, E625, E626, E627, E628, E629, E630, E631, E632, E633, E634, E635, E636, E637, E638, E639, E640, E641, E642, E643, E645, E647, E648, E649, E650, E651, E652, E653, E654, E655, E656, E657, E687, E688

Set 11.1 - TAC, Cadet and Collaboration Smoke

45H7D 15R

SECTION 08 71 00 Page 32

Door: E022A

2.0 pair butts T4A3786 US10 MK

1 closer 690 STA

1 exit device rim (F14) 2114 4914A 612 STA

1 strike S300 STA

1 doorstop 466 RO

1 kickplate 194S 10"x 46" CSK 612 RO

Door: E033, E034

1.5 pair butts BB1168 5.5" x 4.5" NRP US10 HA

1 closer 690 STA

2 exit device exposed vertical rod FL2214 4914A 612 STA

2 top strikes S300 STA

2 dustproof floor strikes 570 RO

2 doorstop 466 RO smoke seals 208" S88D PE

1 kickplate K1050 10" 4BE CSK 612 RO

2 electric magnetic hold open EM508 24120 x CP Long 689 DO

Door: E022C, E358, E458, E558, E658

2.0 pair butts T4A3786 US10 MK

1 closer 690 STA

1 exit device rim (F14) FL2114 4914A 42" 612 STA

1 strike S300 STA

1 doorstop 466 RO smoke seals 200" S88D PE

1 kickplate K1050 10" 4BE CSK 612 RO

1 electric magnetic hold open EM 508 24120 x CP Long x ER-2.0 689 DO

Set 12.5 - Corridor 3 hour Wide

QDC115 (pull side)

Set 12.1 - Corridor 1 hour Double

Set 12.0 - Corridor Wide

QDC115 (push side)

QDC115 (push side)

SECTION 08 71 00 Page 33

Door: E022D

3 pair butts T4A3786 US10 MK

2 closer 690 STA

2 astragal 18041 PE

1 electrified exit device (30") exposed vertical rod

612 STA

1 exit device exposed vertical rod

(30") Add means of RQE.

FL2214 4914A 612 STA

2 top strikes S300 STA

2 dustproof floor strikes 570 RO

2 doorstop 466 RO

1 card reader by access control

1 power supply (number of units as required) by access control smoke seals 208" S88D PE

2 kickplates K1050 10" 4BE CSK 612 RO

2 electric magnetic hold open EM 508 24130 X CP Long X ER-2 689 DO

Doors: E150D, E159D, E171C, E172A

1.5 pair butts BB1168 4.5" x 4.5" NRP US10 HA

1 electric hinge BB1168 4.5" x 4.5" ETW-8 US10 HA

2 closers QCD115 (push side) 690 STA

2 electrified exit devices (35") exposed vertical rod

612 STA

2 top rods (field modify to actual height) TR1855/TR1857 as required 612 STA

2 top strikes S300 STA

2 dustproof floor strikes 570 RO

1 card reader by access control

1 power supply (number of units as required) by access control weatherstrip 248" 2891AS PE

2 kickplates K1050 10" 4BE CSK 612 RO

1 threshold 2005AV 304/4 PE

2 astragal 18041 GNB Gray PE

2 sweeps 345 DNB (612) PE

QDC115 (push side)

Set 12.6 - Corridor Secure Double

Set 13.0 - Double Exterior Historic Safe

E FSE TDS 2203 CD 4903A RQE DS

E FSE TDS 2203 CD 4903A RQE DS

SECTION 08 71 00 Page 34

1.5 pair butts BB1168 5.5" x 4.5" NRP US10 HA

1 electric hinge BB1168 5.5" x 4.5" ETW-8 US10 HA

1 closer QDC115 (push side) 690 STA

1 electrified exit device (40") rim

(F14)

612 STA

1 strike S300 612 STA

1 card reader by access control

1 power supply (number of units as required) by access control weatherstrip 216" 2891AS PE

1 kickplate K1050 10" 4BE CSK 612 RO

1 threshold 2005AV 304/4 PE

1 sweep 345 DNB (612) PE

Doors: D371C

1.5 pair butts TA2714 US10 MK

1 closer QDC117 (push side) 690 STA

1 mortise lockset double keyed (F35) 45H7S 15R 612 STA

1 construction core 1CC STA

1 SFIC permanent core 612

1 strike S6 STA

1 kickplate K1050 10" 4BE CSK 612 RO

1 sweep 345 ANB PE weatherstrip 212" 2891AS PE

1 threshold 252 x 3SSFG 304/4 PE

Gates: Rooftop Mechanical Platform. Five pairs of gates.

2 continuous hinges x 102" HS303 630 MK

1 hasp 7.5" 941 Extra Heavy 630 STA

1 padlock 11B T WC 626 BE

2 crash chains 4048 603 TRI

Set 13.3 - Mechanical Yard Gates Double

Set 13.2 - Corridor Exterior

1C Series - match existing system

Set 13.1 - Exterior Historic Secure Wide

E FSE TDS 2114 CD 4914A RQE DS

40"

Doors: E145A, E145B, E145C, E149A, E149B, E160A, E160B, E161A, E161B, E162A, E162B, E162C, E162D, E701B, E174

SECTION 08 71 00 Page 35

File details come from the government source that posted it. Updated .