Building 518 Replace Chillers

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
5845871
Agency
Naval Facilities Engineering Command Department of the Navy, Department of Defense
Responses due
Set-aside
HUBZone

Opportunity facts

NAICS code
236220 Commercial and Institutional Building Construction
PSC
Z2CA Repair Or Alteration Of Schools
Place of performance
Groton CT 06349 USA

Notice details come from SAM.gov. Updated .

Notice text

** Only those Contractors listed in the RFP MACC solicitation below will be allowed to bid on this requirement.

1. The Oak Group Inc.

2. Pontiac Drywall Systems, Inc.

3. QBS, Inc.

4. Smart ATI/KMK Joint Venture

The scope of this project is to provide and commission two new chillers with associated chilled water and condenser water pumps for Building 518 located at SUBASE New London in Groton, CT.  The chilled water plant was originally designed for three chillers and three roof mounted cooling towers.  The current system uses two chillers and two roof mounted cooling towers. 

The base bid for this project must replace one of the existing chillers, associated pumps, and provide a new third chiller with associated pumps; resulting in three chillers total for the facility.  Replacement of the other existing chiller is detailed as part of Option #1 below. 

The existing cooling towers were installed in 2019.  See Part 6 – Attachments of the SOW for detailed information regarding original system configuration and equipment information.  Reuse existing equipment pads to the greatest extent possible. 

New equipment must be selected based on efficiency, capacity and features (not manufacturer).  A cooling load analysis is not required; however, a sequence of operation detailing the staging of the chillers must be provided. 

New equipment must meet or exceed the energy efficiency ratings of ASHRAE 90.1-2013 as specified in UFC 1-200-02.  New equipment must be fully integrated into the buildings DDC system.  Equipment and controls must be commissioned by a first-tier commissioning subcontractor.  The list of equipment for the Base Bid is detailed in Table 1 below.  B518 is a secure facility.  Project will require escorts (Government provided) for work inside the building.  Refer to Part 6 – Attachments of SOW for record drawings, system diagrams and sequences of operation. (Attachment A)

BID OPTIONS

Option #1: Replace existing chiller (Chiller – 1) and associated pumps.

Option #2: Provide temporary chiller(s) to maintain chilled water service to the building for a duration of three months. Total capacity of temporary chiller(s) must not exceed 300 tons.

Attachments

Files attached to this notice, newest first
File Type Posted
RFP 5845871 Amendment 0003.pdf PDF
BASE MAP 09-14-2017 (1).pdf PDF
B518 Architectural Record Drawings.pdf PDF
part_3_statement_of_work_R1.pdf PDF
B518 Electrical Record Drawings.pdf PDF
RFP 5845871 Amendment 0002.pdf PDF
RFP 5845871 Amendment 0001.pdf PDF
(C) Wages CT20210024.pdf PDF
(G) General Req Revised -9 2018.pdf PDF
(K) 2016-R-0149.pdf PDF
(B) Price Proposal Form.pdf PDF
(D) Base Access Pass Request.pdf PDF
RFP 5845871 B518 Replace Chillers.pdf PDF
(A) B518 Replace Chillers Specs.pdf PDF
(E) NAVFAC RFI form.pdf PDF
(F) 01 31 23.13 20 ECMS Spec.pdf PDF
(H) BASE MAP BLDG 135.pdf PDF
(I) 52.204-24.pdf PDF
(J) Building Contractors Guide to Taxes.pdf PDF
(L) CERT-141.pdf PDF
(M) Limitations on Subcontracting.xls XLS spreadsheet
Show all 21

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Building 518 Replace Chillers Award Award Notice
Building 518 Replace Chillers This notice · Latest solicitation Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity