This is a comprehensive set of bid documents for the Woodrow Wilson Elementary School Elevator Addition project in Waterbury, Connecticut, issued by the State of Connecticut Department of Education (State Project No. 151-0316). The project involves the design and construction of an elevator addition to provide ADA accessibility to the school building, including new elevator installations on the first, second, and third floors, a new vestibule, concrete sidewalks for accessible routes, and associated site improvements. The project was issued for bid on February 6, 2026, with an original construction document date of January 15, 2026. The scope of work encompasses 225 square feet of new construction additions to the existing 44,455 square foot facility, bringing the total facility to 44,846 square feet. The documents include architectural, structural, mechanical, electrical, and civil engineering drawings prepared by Friar Architecture (21 Talcott Notch Road, Farmington, Connecticut), with structural engineering by Michael Horton Associates, Inc. (Branford, Connecticut), MEP engineering by Consulting Engineering Services (Middletown, Connecticut), and civil engineering by Alfred Benesch & Co. (Glastonbury, Connecticut).
The construction documents specify compliance with the 2021 International Building Code and Connecticut amendments, including requirements for fire-rated walls, sprinkler systems, seismic design, and accessibility standards (ICC A117.1-2017). The project requires selective demolition of existing windows and walls, underpinning of existing foundations, and new construction incorporating 8-inch concrete masonry units, brick veneer, metal panel systems, and structural steel framing. Key mechanical components include a new electric unit heater (QMark CDF-548) in the elevator lobby. Electrical work includes dedicated circuits for elevator power and controls, emergency lighting, fire alarm integration with existing systems, and video intercom infrastructure. The electrical contractor must coordinate with the existing fire alarm system (Edwards Systems Technology EST2) and access control systems. Site work involves erosion and sediment control measures, drainage improvements including a new drywell and pump station, new concrete sidewalks, and chain-link fencing. Contractors must verify all existing conditions, coordinate utility locations via Call Before You Dig, and submit shop drawings for structural steel, reinforcing, and mechanical equipment prior to fabrication.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Driggs Wilson Elevator Specs.pdf | ||
| ITB 8703- Wtby_Mar_2_26_solicitation_doc.pdf | ||
| RFP 8703 Addendum 2.pdf | ||
| RFP 8703 Addendum 2.pdf.crdownload | CRDOWNLOAD file | |
| Driggs Elevator Bid Documents.pdf | ||
| ITB 8703- Wtby_Mar_30_26_solicitation_doc.pdf | ||
| Driggs Elevator Bid Documents.pdf.crdownload | CRDOWNLOAD file | |
| RFP 8703 Addendum 1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SITE LOCATION MAP
INDEX OF DRAWINGS
REBMUNTES
WOODROW WILSON ELEMENTARY SCHOOL
ELEVATOR ADDITION
235 BIRCH STREET
WATERBURY, CONNECTICUT
STATE PROJECT NO. 151-0316 LUE
1/15/2026
ISSUE FOR BID: 2/6/2026
ARCHITECT
CIVIL ENGINEER
ALFRED BENESCH & CO.
120 HEBRON AVENUE, 2ND FLOOR
GLASTONBURY, CT 06033
FRIAR ARCHITECTURE
21 TALCOTT NOTCH ROAD
FARMINGTON, CONNECTICUT
MAYOR
HONORABLE PAUL K. PERNEREWSKI, JR
SUPERINTENDENT OF SCHOOLS
DR. DARREN SCHWARTZ
STRUCTURAL ENGINEER
MICHAEL HORTON ASSOCIATES, INC.
780 EAST MAIN STREET
BRANFORD, CT 06405
MEP/FP ENGINEER
CONSULTING ENGINEERING SERVICES
811 MIDDLE STREET
MIDDLETOWN, CT 06457
REFERENCE
R1.1 REFERENCE SHEET
R1.2 FIRST & SECOND FLOOR EGRESS PLANS
R1.3 THIRD FLOOR EGRESS PLAN
CIVIL
C1.0 DEMOLITION & SITE PREPARATION PLAN
C1.1 EROSION & SEDIMENTATION CONTROL NOTES & DETAILS
C2.0 SITE PLAN
DEMOLITION
D1.1 DEMOLITION PLANS
ARCHITECTURE
A1.1 NEW WORK FLOOR PLANS
A2.1 ROOF PLAN & DETAILS
A3.1 BUILDING ELEVATIONS
A6.1 LARGE SCALE ELEVATOR PLANS
A6.2 LARGE SCALE ELEVATOR SECTIONS & DETAILS
A7.1 PLAN, SECTION & CEILING DETAILS
A8.1 WINDOW & DOOR ELEV, DETAILS, AND SCHEDULE
A9.1 REFLECTED CEILING
A12.1 FINISH PLAN
STRUCTURAL
S0.0 GENERAL NOTES
S1.0 NEW WORK FLOOR PLANS
S2.0 FOUNDATION, FLOOR AND ROOF SECTIONS
S3.0 TYPICAL DETAILS
MECHANICAL
M0.0 MECHANICAL ABBERVIATIONS, NOTES AND SYMBOLS
M1.1 MECHANICAL NEW WORK PLANS
ELECTRICAL
E0.0 ELECTRICAL ABBERVIATIONS, NOTES AND SYMBOLS
ED1.1 ELECTRICAL DEMOLITION PLANS
E1.1 ELECTRICAL POWER NEW WORK PLANS
E1.2 ELECTRICAL LIGHTING NEW WORK PLANS
E5.0 ELECTRICAL DETAILS
E6.0 ELECTRICAL SCHEDULES AND DIAGRAMS
MOUNTING HEIGHTS
ELECTRICAL MOUNTING HEIGHTS
ALL MOUNTING HEIGHTS TO BE COORDINATED WITH BLOCK COURSING AS OCCURS. CONSULT
ARCHITECT IF EXISTING CONDITIONS DIFFER
ALL DIMENSIONS ARE TO THE CENTER OF DEVICE UNLESS OTHERWISE NOTED.
SEE ELECTRICAL DRAWINGS FOR TYPES AND LOCATIONS.
RECEPTACLES : 18" A.F.F. ( AT LOCATIONS ABOVE CASEWORK, MOUNT BOTTOM OF RECEPTACLE
AT 2" ABOVE BACKSPLASH. AT LOCATIONS BELOW CASEWORK, MOUNT AT 24" A.F.F.)
WIREMOLD: 24" A.F.F. ( AT LOCATIONS ABOVE CASEWORK, MOUNT BOTTOM OF WIREMOLD AT 2"
ABOVE BACKSPLASH )
EXTERIOR RECEPTACLES: 24" A.F.G. (20" A.F.F.)
SWITCHES: 48" A.F.F.
BOILER EMERGENCY SWITCHES: 60" A.F.F.
DATA/PHONE OUTLETS: 18" A.F.F.
TV OUTLETS: 18" A.F.F. OR 18" BELOW FINISHED CEILING*
*FIELD VERIFY CEILING HEIGHTS WITH COORDINATION DRAWINGS
WALL PHONE: 48" A.F.F. TO CENTER OF EARPIECE
SECURITY KEYPAD: 48" A.F.F.
MICROPHONE WALL JACK: 48" A.F.F.
FIRE ALARM PULL STATION: 48" A.F.F.
FIRE ALARM VISUAL/AUDIO INDICATING UNITS: 6'-8" TO BOTTOM OF UNIT
AREA OF REFUGE CALL STATION: 48" A.F.F.
EMERGENCY SHUT-OFF SWITCH / PUSH BUTTON: 48" A.F.F.
EMERGENCY CALL SWITCH: 36" A.F.F.
EMERGENCY CALL BELL / LIGHT: +/- 7'-6" A.F.F., CENTER ABOVE DOOR
WALL MOUNTED EXIT SIGNS: 7'-6" A.F.F
WALL MOUNTED CLOCKS AND SPEAKERS: +/- 7'-6" A.F.F.
NOTES
CONSTRUCTION NOTES
GENERAL NOTES
1. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL CODES AND ORDINANCES.
2. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION OF DIMENSIONS FROM
THE ARCHITECT BEFORE CONTINUING WITH CONSTRUCTION.
3. CONTRACT DRAWINGS MAY VARY FROM ACTUAL FIELD CONDITIONS. CONTRACTOR SHALL CORRECT DIMENSIONS OF ALL
MATERIALS TO CARRY OUT OF THE INTENT OF THE CONTRACT DRAWINGS. VERIFY ALL DIMENSIONS AND EXISTING
CONDITIONS IN FIELD BEFORE ORDERING ANY MATERIALS. CONTRACTOR SHALL NOTIFY ARCHITECT PROMPTLY OF ANY
CRITICAL DISCREPANCIES BEFORE PROCEEDING WITH WORK.
4. ALL NEW WORK SHALL BE IMPLEMENTED SO AS TO PROVIDE A SMOOTH AND CONTINUOUS SURFACE WITH ALL EXISTING
CONDITIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK NECESSARY TO ACHIEVE THIS REQUIREMENT, EVEN
THROUGH PROCEDURES ARE NOT DETAILED FOR EACH SPECIFIC CONDITION OR COMBINATION OF CONDITIONS. QUALITY OF
WORKMANSHIP, MATERIALS AND FINISHES SHALL BE EQUAL TO THE LEVEL ESTABLISHED FOR SIMILAR CONSTRUCTION, EXCEPT WHERE EXISTING APPEARANCE IS TO BE MATCHED TO ACHIEVE CONTINUITY.
5. CUTTING AND PATCHING SHALL BE THE RESPONSIBILITY OF THE TRADE WHOSE WORK RESULTS IN THE NEED FOR CUTTING
AND PATCHING UNLESS A SPECIFIC CONTRACTOR IS CALLED OUT ON THE DRAWINGS. ALL HOLES LEFT BY REMOVING
MECHANICAL, PLUMBING AND ELECTRICAL EQUIPMENT, ETC. SHALL BE PATCHED.
6. UNLESS OTHERWISE NOTED OR DIMENSIONED, NEW PARTITIONS SHALL BE CENTERED ON BUILDING COLUMN GRID OR
WINDOW MULLIONS.
7. CONTRACTOR SHALL PROVIDE WOOD BLOCKING AT WALLS AS REQUIRED TO SUPPORT SHELVES, CABINETS TV BRACKETS AND
RELATED ITEMS.
8. WHERE REQUIRED, SEISMIC BRACING SHALL BE PROVIDED AT SUSPENDED CEILINGS. SEE A9.1.
9. ALL EGRESS DOORS SHALL BE NON-LOCKING IN DIRECTION OF TRAVEL.
10. ALL PARTITIONS ARE TO EXTEND TO UNDERSIDE OF DECK ABOVE.
1.) DIMENSION CRITERIA
A. FROM FACE TO METAL STUD TO FACE OF METAL STUD
B. FROM FACE TO METAL STUD TO FACE OF CONCRETE MASONRY UNIT
C. FROM FACE TO CONCRETE MASONRY UNIT TO FACE OF CONCRETE MASONRY UNIT
ABBREVIATIONS
ABOVE FINISH FLOOR
ABOVE FINISH GRADE
ACOUSTIC TILE
AIR CONDITIONING
AIR HANDLING UNIT
ALTERNATE
ALUMINUM
ANCHOR, ANCHORAGE
ANCHOR BOLTS
ANGLE
ANODIZED
APPROVED
ARCHITECTURAL / ARCHITECT
ASBESTOS
ASPHALT
ASSEMBLY
ASSISTANT
AT
AUTOMATIC
BEAM
BEARING
BETWEEN
BEVEL / BEVELED
BITUMINOUS
BLOCK
BLOCKING
BOARD
BOTTOM OF
BOTTOM
BUILDING
BUILT-UP ROOF
CABINET UNIT HEATER
CAPACITY
CEILING
CEILING HEIGHT
CEMENT
CENTER
CENTERLINE
CERAMIC
CHALKBOARD
CHANNEL
CLOSET
COLUMN
CONFERENCE
CONTROL OR
CONSTRUCTION JOINT
CONTINUOUS
CONTRACTOR
CORRIDOR
COURSE / COURSES
DAMPPROOFING
DEGREE
DEMOLITION
DEPARTMENT
DETAIL
DIAMETER
DIMENSION
DISTANCE
DOOR
DOUBLE
DOUBLE HUNG
DOWN
DOWNSPOUT
DRAWING
DRINKING FOUNTAIN
EACH
ELECTRIC / ELECTRICAL ELECTRICAL
WATER COOLER
ELEVATION
ELEVATOR
EXISTING FIRE EXTINGUISHER
EMERGENCY
EQUAL
EQUIPMENT
EXISTING
EXISTING TO REMAIN
EXPANSION JOINT
EXTERIOR INSULATION
FINISH SYSTEM
FEET, FOOT
FINISH, FINISHED
FIRE DAMPER
FIRE EXTINGUISHER/FIRE BLANKET
CABINET
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER & BRACKET
FIRE RETARDANT
FIREPROOFING
FIXTURE
FLASHING
FLOOR DRAIN
FLOOR FINISH
FOOTING
FOUNDATION
FUME HOOD
FURNISH / FURNISHED
FURRED / FURRING
INCH OR INCHES
INCLUDE / INCLUDING
INFORMATION
INSIDE DIAMETER
INSULATION
INTERIOR
JOINT
KICK PLATE
LABORATORY
LAVATORY
LIGHTING
MACHINE
MAINTENANCE
MANUFACTURER
MARKER BOARD
MASONRY
MASONRY OPENING
MATERIAL
MAXIMUM
MECHANICAL
METAL
MEZZANINE
MINIMUM
MISCELLANEOUS
OFFICE
ON CENTER
OPPOSITE HAND
OPENING
OUTSIDE DIAMETER
PAINTED
PAIR
PAPER TOWEL DISPENSER
PERPENDICULAR
PLASTER
PLASTIC LAMINATE
PLATE
PLUMBING
PLYWOOD
PRECAST
PREFABRICATED
PRESSURE TREATED
PROJECT, PROJECTION POINT
QUANTITY
QUARRY TILE
RADIUS
RAIN WATER LEADER
RECEIVING
REFRIGERATOR
REINFORCED / REINFORCING
REQUIRED
REVISION / REVISED
RISER
ROOF DRAIN
ROOM
SANITARY NAPKIN DISPENSER
SANITARY NAPKIN
SCHEDULE
SCUPPER
SECTION
SEISMIC JOINT
SERVICE SINK
SHEET
SHOWER/EYEWASH
SIMILAR
SOAP DISPENSER
SOUND TRANSMISSION CLASS
SPECIFICATIONS
SPLASH BLOCK
SQUARE
SQUARE INCH (S)
SQUARE YARD (S)
SQUARE FEET (FOOT)
STAINLESS STEEL
STANDARD
STEEL
STORAGE
STRUCTURAL
STRUCTURAL GLAZED
FACING TILE
STRUCTURAL STEEL
SUSPEND, SUSPENSION
SURFACE
SYSTEM
TACKBOARD
TELEPHONE
TEMPERATURE / TEMPORARY
TOUNGE & GROOVE
THRESHOLD
THICK
TOILET
TOP OF
TREAD
TYPICAL
UNDERWRITER'S LABS
UNIT HEATER
UNIT VENTILATOR
UNLESS NOTED OTHERWISE
URINAL
VENT THROUGH ROOF
VERIFY IN FIELD
VERTICAL
VINYL ASBESTOS TILE
VINYL COMPOSITION TILE
WATER CLOSET
WATERPROOFING
WELDED WIRE FABRIC
WEIGHT
WHITE BOARD
WITH
WOOD
A.F.F.
A.F.G.
AC.,A.C.T.
A.C.
A.H.U.
ALT.
ALUM.
ANCH.
ABL
ANG
ANOD.
APPD.
ARCH.
ASB.
ASPH.
ASSY.
ASST
AUTO.
BM.
BRG.
BET.
BEV.
BIT.
BLK.
BLKG.
BD.
B/O
BTM.
BLDG.
B.U.R.
C.U.H.
CAP.
CLG.
CLG.HGT.
CEM.
CTR.
CL
CT
C.BD.
CH.
CLOS.
COL
CONF.
C.J.
CONT.
CONTR.
CORR.
CRS.
DAMPR.
DEG.
DEMO.
DEPT.
DET.
DIA.
DIM.
DIST.
DR.
DBL.
D.H.
DN.
D.S.
DWG.
D.F.
EA.
ELEC.
EWC.
EL.
ELEV.
EXFE
EMG.
EQ.
EQUIP.
EXIST.
ETR.
E.J.
EXT. EIFS.
FT.
FIN.
FD.
FEB
FEC
FE
FR.
FPRFG.
FIXT.
FLASH. FL.
FD.
FLR. FIN.
FTG.
FDN.
F.H.
FURN.
FURR
IN.
INCL.
INFO.
I.D.
INSUL.
INT.
JT.
KP.
LAB.
LAV.
LTG.
MACH.
MAINT.
MFR.
MBD.
MAS.
M.O.
MATL.
MAX.
MECH.
MET.
MEZZ.
MIN.
MISC.
OFF.
O.C.
O.H.
OPG.
O.D.
PTD.
PR.
P.T.D.
PERP.
PLAS.
P.LAM.
PL.
PLBG.
PLYWD.
P.C.
PREFAB.
PROJ. PT.
P.T.
QTY.
Q.T.
RAD.
RWL.
RECV.
REF.
REINF.
REQ'D.
REV.
R
R.D.
RM.
S.N.D.
S.N.R.
SCHED.
SC.
SECT.
S.J.
S.S.
SHT.
S/E
SIM.
S.D.
S.T.C.
SPEC.
S.B.
SQ.
SQ.IN.
SQ.YD.
S.F.
ST. STL.
STD.
STL.
STOR.
STRUCT.
SGFT.
STRUCT. STL.
SUSP.
SURF.
SYS.
TBD.
TEL.
TEMP.
T & G
THLD.
THK.
TLT
T/O
T.
TYP.
U.L.
U.H.
U.V.
U.N.O.
UR.
V.T.R.
V.I.F.
VERT.
V.A.T.
V.C.T.
W.C.
W.P.
W.W.F.
WT.
WBD.
W/
WD.
INTERIOR ABBREVIATIONS
ACID
AWP
BB
BC
C
CC
CMT
CTB
CTR
CWT
DCPL
DC
DST
DW
EM
EG
EP
EPR
ER
ERS
ET
ETR
FEB
FEC
FE
FC
FLAM
GBB
GC
GT
HB
HPWP
HR
ICE
INTBD
L
LK
LRF
LS
LT
LVT
MC
MBD
MCIC
MP
MS
MW
P
ACID CABINET
ACOUSTICAL WALL PANEL
BUTCHER BLOCK COUNTERTOP
BASE CABINET
CARPET (TILE AND/OR BROADLOOM)
CUBICAL CURTAIN
CEMENTITIOUS TOPPING
CERAMIC TILE BASE
COUNTER
CERAMIC WALL TILE
DECORATIVE WALL PANEL
DISPLAY CASE
DISTILLER
DISHWASHER (GLASSWARE)
ENTRY MAT
ENTRY GRILLE
EPOXY PAINT
EXPLOSION PROOF REFRIGERATOR
EPOXY RESIN FLOORING
EPOXY RESIN COUNTERTOP
EPOXY TERRAZZO
EXISTING TO REMAIN
FIRE EXTINGUISHER/FIRE BLANKET CABINET
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER & BRACKET
FOLIO CABINET
FLAMMABLE CABINET
GLAZED BLOCK BASE
GOGGLE CABINET
GROUT
HORIZONTAL BLINDS
HIGH PRESSURE WALL PANEL
HANDRAILS, RAILINGS & STRINGERS
ICE MAKER
INTELLIGENT BOARD
LINOLEUM
LOCKER
LUXURY RESILIENT FLOORING
LINOLEUM SHEET FLOORING
LINOLEUM TILE
LUXURY VINYL TILE
METAL CABINETRY
MARKERBOARD
MULTI-COLORED INTERIOR COATING
METAL PANEL
MOTORIZED SHADE
MICROWAVE
PAINT
PC
PCF
PJS
PL
PR
PT
PTD
QT
QTB
RB
REF
RT
RST
SC
STCT
STGC
SF
SF
SS
SSG
STS
SV
SVS
SVT
TBD
TF
TS
UC
UCR
V
VB
VCT
VS MBD
VT
VWC
WB
WC
WD
WDC
WDT
WDU
WM
WP
WS
PRIVACY CURTAIN
PAINTED CONCRETE FLOOR
PROJECTION SCREEN
PLASTIC LAMINATE
PHENOLIC RESIN COUNTERTOPS
PORCELAIN TILE
PAPER TOWEL DISPENSER
QUARRY TILE
QUARRY TILE BASE
RUBBER BASE
REFRIGERATOR
RUBBER TILE
RUBBER STAIR TREAD/RISERS
SEALED CONCRETE
STAINED CONCRETE
STAGE CURTAIN
EMERGENCY SHOWER/EYEWASH
SPORTS FLOOR
SOLID SURFACE
SAFETY SHEET GOOD
STAINLESS STEEL COUNTERTOP
SHEET VINYL FLOORING
SOLID VINYL SHEET GOOD
SOLD VINYL TILE
TACKBOARD
TERRAZZO FLOORING
TACK STRIP
UPPER WALL CABINET
UNDER COUNTER REFRIGERATOR
VENEER CABINETRY
VINYL BASE
VINYL COMPOSITE TILE
VERTICAL SLIDING WHITEBOARD
VINYL TILE
VINYL WALL COVERING
WALL BASE
WALL COVERING
WOOD
WOOD CASEWORK
WOOD TALL CABINETS
WOOD UPPER CABINETS
WALK-OFF MAT
WALL PROTECTION/PADDING
WINDOW SHADES
BUILDING SECTION
ARCHITECTURAL SYMBOLS
WALL SECTION
COLUMN CENTERLINE
DETAIL DESIGNATION, PLAN DETAIL,
LARGE SCALE PLANS
INTERIOR ELEVATIONS
CASEWORK ELEVATIONS
CEILING DESIGNATION
ROOM NUMBER
DOOR NUMBER
WINDOW DESIGNATION
DEMOLITION TAG
WALL TYPES
PHOTO LOCATION
REVISION NUMBER
DATUM / ELEVATION / LEVEL LINE
EXISTING CONSTRUCTION TO REMAIN
NEW STUD CONSTRUCTION
NEW CONCRETE BLOCK
NEW FACE BRICK
SOFFITS / OVERHANG ABOVE
THIS REPRESENTS A 30"X48" ADA
WHEELCHAIR CLEARANCE. IT ALSO
REPRESENTS A 30" CLEAR WIDTH.
ACCESSIBLE ELEMENT
AREA OF REFUGE WHEELCHAIR SPACE ACCESS.
CLEAR FLOOR SPACE ASSEMBLY WHEELCHAIR
SEAT 30"x48" CLEAR FLOOR SPACE
CORNER GUARD
SECTION NUMBER
SHEET NUMBER
SECTION NUMBER
SHEET NUMBER
LETTERS (HORIZ.)
SHEET NUMBER
NUMBERS (VERT.)
DETAIL NUMBER
SHEET NUMBER
ELEVATION NUMBER
ELEVATION NUMBER
CEILING TYPE (LETTER)
CEILING HEIGHT (NUMBER)
NUMBER
NUMBER/TYPE
LETTER/TYPE
NUMBER
NUMBER
PHOTO NUMBER
NUMBER
MIN.
30" CLR
M
IN
C
LR
METAL (SMALL)
METAL LATH
MARBLE
GYPSUM BOARD
GRAVEL
GLAZING
GLAZED BRICK
GLASS BLOCK
FIRE BRICK
FINISHED WOOD
FACE GRAIN
FACE BRICK
FLAT METAL PANEL
SLATE, FLAGGING,
SOAPSTONE
METAL PANEL
CORRUGATED
GLASS
CERAMIC TILE
CONCRETE BLOCK
BRICK
ELEVATIONS
TERRAZZO
TERRA-COTTA
STRUCT. GLAZED
FACING TILEEARTH
CONCRETE
C.M.U.
STRUCTURAL CLAY
STEEL
SLATE, FLAGGING,
SOAPSTONE
CERAMIC TILE
CAST STONE
CARPET
SHEATHING INSUL.
RUBBLE
ROUGH WOOD
(INTERRUPTED)
BRASS OR BRONZE
BITUMINOUS
BATT INSULATION
ROUGH WOOD
(CONTINUOUS)
RIGID INSULATION
PLYWOOD ( SMALL)
ACOUSTICAL TILE PLASTER
ALUMINUM
ARCHITECTURAL MATERIALS
TYPICAL NOTES
1. ALL ACOUSTICAL WALL ASSEMBLIES ARE TO BE SEALED TOP AND BOTTOM, TERMINATE
AT THE UNDERSIDE OF THE FLOOR ABOVE OR THE ROOF ABOVE, TYPICAL.
2. ALL FIRE RATED WALLS ARE TO BE SEALED TOP AND BOTTOM, TERMINATE AT THE
UNDERSIDE OF THE FLOOR ABOVE OR THE ROOF ABOVE, TYPICAL.
3. ALL INTERIOR WALLS ARE TO BE SEALED TOP AND BOTTOM, TERMINATE AT THE
UNDERSIDE OF THE FLOOR ABOVE OR THE ROOF ABOVE, TYPICAL.
4. FOR BOND BEAMS, REINFORCING AND OR SHEAR WALLS, REFER TO STRUCTURAL
DRAWINGS, TYPICAL.
5. SEAL ALL THRU WALL PENETRATIONS TO MAINTAIN CONSISTENT FIRE, SMOKE AND STC
RATINGS. ALL PENETRATIONS INCLUDING BUT NOT LIMITED TO ALL ELECTRICAL
(CONDUITS & BOXES), MECHANICAL (DUCTS, PIPES), PLUMBING AND FIRE PROTECTION
PIPING. SEE WALL TYPES FOR ASSOCIATED RATINGS AND SEE SEALANT SPECIFICATIONS
FOR TYPES.
6. CONTRACTOR TO VERIFY THAT ALL FIRE ASSEMBLIES ARE CONSTRUCTED IN
ACCORDANCE WITH APPROVED LISTED ASSEMBLIES PER CURRENT U.L. FIRE
RESISTANCE DIRECTORY.
7. MOISTURE RESISTANT GYPSUM BOARD IS TO BE USED IN LIEU OF ABUSE RESISTANT
GYPSUM BOARD ON ALL INTERIOR FACES OF TOILET ROOMS.
8. ALL INTERIOR GYPSUM WALL PARTITIONS TO HAVE ABUSE RESISTANT GYPSUM
BOARD CONSTRUCTION EXTENDING 1'-0" ABOVE CEILING HEIGHT. STANDARD
GYPSUM BOARD SHALL BE USED ABOVE CEILING AND EXTENDING TO DECK ABOVE.
EXCEPT WHERE NOTED OTHERWISE.
9. NOT ALL WALL TYPES SHOWN ARE USED IN PROJECT. REFER TO FLOOR PLAN.
A
EXTERIOR
3" RIGID INSULATION
1 3/4" AIR SPACE
4" BRICK
INTERIOR
SELF ADHERING AIR VAPOR BARRIER
8" CONCRETE MASONRY UNIT, HORIZONTAL
REINFORCEMENT EVERY 16" VERTICALLY
EXTERIOR
2" RIGID INSULATION
2" METAL Z-GIRT @ 16" O.C.
1" METAL PANEL SYSTEM, HORIZONTAL ORIENTATION
INTERIOR
SELF ADHERING AIR VAPOR BARRIER
BATT INSULATION
1/2" EXTERIOR GRADE PLYWOOD SHEATHING
6" METAL STUD @ 16" O.C.
5/8" ABUSE RESISTANT GYP.
B
EXTERIOR WALL TYPES
-1 /4
8" CONCRETE MASONRY UNIT,
HORIZONTAL REINFORCEMENT EVERY
16" VERTICALLYSTC = 42
INTERIOR WALL TYPES
1A
8" CONCRETE MASONRY UNIT
7/8" METAL STUD FURRING AND 5/8" GYPSUM WALLBOARD
3-5/8" METAL STUD @ 16" O.C.
5/8" ABUSE RESISTANT GYP. (ONE SIDE)
EXTEND TO MINIMUM 6" ABOVE
FINISHED CEILING
1-5/8" METAL STUD @ 16" O.C.
5/8" ABUSE RESISTANT GYP. (ONE SIDE)
EXTEND TO MINIMUM 6" ABOVE
FINISHED CEILING
SHEET NO.
PROFESSIONAL SEAL
21 Talcott Notch Road
Farmington, CT 06032 friar.com
860.678.1291
CONSULTANT
DATE:
SCALE
PROJ. #:
DRAWN:
CHECKED:
3/4" = 1'-0"
R1.1
REFERENCE SHEET
WOODROW WILSON
ELEMENTARY
SCHOOL ELEVATOR
ADDITION
STATE PROJECT NUMBER
235 BIRCH STREET
WATERBURY, CT 06704
BKH
JMY
2022-049A
1/15/2026
151-0316 LUE
Date of Original Construction
1. GROUP CLASSIFICATION
(Primary) (Incidental)
Renovation
EDUCATION (E)
20261950
CODE INFORMATION
3. CODES TO WHICH THIS PROJECT WAS DESIGNED Dated:
2. SPRINKLER PROTECTION
EXISTING UNRENOVATED CONSTRUCTION
5. BUILDING AREAS FOR GRANT CALCULATIONS (ENTIRE FACILITY)
NoYes4. THRESHOLD BUILDING CONDITIONS X
EXISTING RENOVATED CONSTRUCTION
TOTAL EXISTING CONSTRUCTION
EXISTING BEING DEMOLISHED
TOTAL NEW CONSTRUCTION
TOTAL FACILITY
44,455 SF
Limited Area
Entire Building
X
225 SF
44,680 SF
166 SF
44,846 SF
2021 International Building Code *
2021 International Mechanical Code *
2021 International Plumbing Code *
2021 International Energy Conservation Code *
2019 Installation of Sprinkler Systems (NFPA 13)
2021 Life Safety Code (NFPA 101) *
2021 Fire Code (NFPA 1) *
2021 International Residential Code *
2021 International Existing Building Code *
2017 Accessible and Usable Buildings and Facilities (ICC A117.1-2017)*
2020 National Electrical Code (NFPA 70)*
2021 International Fire Code *
2021 International Swiming Pool & Spa Code *
* With Connecticut Amendments and General Statute requirements
REVISIONS
NO. DATE DESCRIPTION
2/6/2026 ISSUE FOR BID
DIRECTION OF TRAVEL
WITH ACCUMULATED OCCUPANCY LOAD
MAXIMUM TRAVEL DISTANCE
FROM FURTHEST POINT
NOTES:
ROOM NUMBER
OCCUPANCY LOAD FACTOR
AREA IN SQUARE FEET
EXIT CAPACITY
ROOM OCCUPANCY LOAD
MAXIMUM ALLOWABLE EGRESS OCCUPANCY OF DOOR OR STAIR
ACTUAL EGRESS OCCUPANCY OF DOOR OR STAIR
EGRESS PLAN LEGEND
2 HOUR RATED WALL
(TIGHT TO DECK ABOVE)
1 HOUR RATED WALL
(TIGHT TO DECK ABOVE)
SMOKE PARTITION
(TIGHT TO DECK ABOVE)
BUILDING PROPERTY LINE
BR Balance Exit. Minimum number of exits required per 1018.0
BD Balance Exit. Exit required due to dead end corridor
BA Balance Exit. Exit as required for Assembly space.
BT Balance Exit. Exit as required due to travel distance.
1. A VALUE OF 0.2 INCHES OF WIDTH PER OCCUPANT HAS BEEN USED TO CALCULATE DOOR
AND CORRIDOR EGRESS CAPACITY. IN ALL CASES, THE ACTUAL CLEAR OPENING OF THE
DOOR AND ACTUAL CLEAR WIDTH OF THE CORRIDOR IS USED.
2. A VALUE OF 0.3 INCHES OF WIDTH PER OCCUPANT HAS BEEN USED TO CALCULATE
STAIRWAY EGRESS CAPACITY. IN ALL CASES, THE ACTUAL CLEAR WIDTH BETWEEN
STRINGERS IS USED.
UNUSED
CORRIDOR
STORAGE
TOILET
NEW BOILER
ROOM
CUSTODIAN
SPRINKLER ROOM
STORAGE
SCIENCE
CORRIDOR OFFICE
GENERATOR
STAIR
TOILET ROOM
COMPRESSOR
ROOM
OLD BOILER
ROOM
CORRIDOR
EX STAIR
=973
=144
=55 1
=212 1
=562 2
=148 1
=183 1
=140
=844 3
=361 2
CRAWL SPACE
OPEN SPACE
22 2421
CLASSROOM
CLASSROOM
CORRIDOR
EX STAIR
B
CLASSROOMNURSES OFFICE
PRINCIPAL
OFFICE
OFFICE
CLASSROOM
CLASSROOM
CLASSROOM
STORAGE
ELECTRICAL
LIBRARY CLASSROOM
CORRIDOR
OFFICE
LAV
TOILET
ROOM
TOILET
ROOM
CLASSROOM
SPECIAL
EDUCATION
STAIR
EXD
CAFETERIA
AUDITORIUM /
GYMNASIUM
STAGE
STORAGE
LOBBY
CUSTODIAN
STAIR
EXC
=684 35
=703 36
=681 35
=398 3
=204 2
=202 2
=689 35
=692 35
=695 35
=123 1
=241 1
=259 2
=775 39
=761 39
=1054 71
=3640
=795 54
=749 38
=1340 9
=172 1
=220
OFFICE
JANITOR
LAUNDRY TOILET
KITCHEN
=190 1
TOILET TOILET
STAIR
EXA
STAIR
EXE
=64 1
3892432 14
SHEET NO.
PROFESSIONAL SEAL
21 Talcott Notch Road
Farmington, CT 06032 friar.com
860.678.1291
CONSULTANT
DATE:
SCALE
PROJ. #:
DRAWN:
CHECKED:
As indicated
R1.2
FIRST & SECOND
FLOOR EGRESS PLANS
WOODROW WILSON
ELEMENTARY
SCHOOL ELEVATOR
ADDITION
STATE PROJECT NUMBER
235 BIRCH STREET
WATERBURY, CT 06704
BKH
JMY
2022-049A
1/15/2026
151-0316 LUE
SCALE: 1/16" = 1'-0"
FIRST FLOOR EGRESS PLAN
SCALE: 1/16" = 1'-0"
SECOND FLOOR EGRESS PLAN
REVISIONS
FAMILY
RESOURCE
CENTER
CLASSROOM
CLASSROOM
SPEECH
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
STAIR
CORRIDOR
BEHAVIORAL
DISORDER
LEARNING
CENTER
STORAGE
PEOPLE
PLANNING ROOM
EX STAIR
STORAGE /
MECHANICAL
P.T.O.
JANITOR
READING CLASSROOM CLASSROOM
CORRIDOR
TEACHERS
LOUNGE
TOILET TOILET COMPUTER
ROOM CLASSROOM CLASSROOM
STAIR
ROOF BELOW
OPEN TO BELOW
ROOF BELOW
OFFICE
LOBBY
OFFICE
NEW ELEVATOR ADDITION
=700
=698 35
=469 10
=122 1
=179 1
=279 6 50=714
=194 2
=708 36
=350 18
=725 37
=351 18
=473
=744
=727
=749
=137 1
=810 41
=771 39
=764 16
=365 8
=85 1
111111
8 9 28 142 80 1
DIRECTION OF TRAVEL
WITH ACCUMULATED OCCUPANCY LOAD
MAXIMUM TRAVEL DISTANCE
FROM FURTHEST POINT
NOTES:
ROOM NUMBER
OCCUPANCY LOAD FACTOR
AREA IN SQUARE FEET
EXIT CAPACITY
ROOM OCCUPANCY LOAD
MAXIMUM ALLOWABLE EGRESS OCCUPANCY OF DOOR OR STAIR
ACTUAL EGRESS OCCUPANCY OF DOOR OR STAIR
EGRESS PLAN LEGEND
2 HOUR RATED WALL
(TIGHT TO DECK ABOVE)
1 HOUR RATED WALL
(TIGHT TO DECK ABOVE)
SMOKE PARTITION
(TIGHT TO DECK ABOVE)
BUILDING PROPERTY LINE
BR Balance Exit. Minimum number of exits required per 1018.0
BD Balance Exit. Exit required due to dead end corridor
BA Balance Exit. Exit as required for Assembly space.
BT Balance Exit. Exit as required due to travel distance.
1. A VALUE OF 0.2 INCHES OF WIDTH PER OCCUPANT HAS BEEN USED TO CALCULATE DOOR
AND CORRIDOR EGRESS CAPACITY. IN ALL CASES, THE ACTUAL CLEAR OPENING OF THE
DOOR AND ACTUAL CLEAR WIDTH OF THE CORRIDOR IS USED.
2. A VALUE OF 0.3 INCHES OF WIDTH PER OCCUPANT HAS BEEN USED TO CALCULATE
STAIRWAY EGRESS CAPACITY. IN ALL CASES, THE ACTUAL CLEAR WIDTH BETWEEN
STRINGERS IS USED.
SHEET NO.
PROFESSIONAL SEAL
21 Talcott Notch Road
Farmington, CT 06032 friar.com
860.678.1291
CONSULTANT
DATE:
SCALE
PROJ. #:
DRAWN:
CHECKED:
As indicated
R1.3
THIRD FLOOR EGRESS
PLAN
WOODROW WILSON
ELEMENTARY
SCHOOL ELEVATOR
ADDITION
STATE PROJECT NUMBER
235 BIRCH STREET
WATERBURY, CT 06704
BKH
JMY
2022-049A
1/15/2026
151-0316 LUE
SCALE: 1/16" = 1'-0"
THIRD FLOOR LEVEL EGRESS PLAN
REVISIONS
l xxx x x x x x x
WALL STREET
SF
SF
SF
SF SF SF SF SF SF SF SF
SF
SF
SF
SF
SF
SF
SF
SF
STK
CWA
CE
HAY BALE BARRIER
CATCH BASIN FILTER INSERT
TEMPORARY CONCRETE WASHOUT
SF
SF
SF
SF
SF
SF
TEMPORARY STOCKPILE
EXISTING PROPERTY LINES
SILT FENCE BARRIERSF SF SF SF
CONSTRUCTION ENTRANCE
STK
CWA
CE
BITUMINOUS PAVEMENT DEMOLITION
CONCRETE WALK/PAD DEMOLTION
FENCE/WALL DEMOLITION
SITE ITEM TO BE REMOVED
TREE PROTECTIONP
BUILDING DEMOLITION
CONSTRUCTION FENCE
LIMIT OF DISTURBANCELOD LOD
TEMPORARY STOCKPILE LOCATION
SILT FENCE (TYP.)
00 10' 20'
SCALE: 1" = 10'
DEMOLITION AND EROSION CONTROL LEGEND
EROSION AND SEDIMENT CONTROL NOTES:
1. THIS PLAN IS FOR EROSION AND SEDIMENTATION (E&S) CONTROL ONLY. SEE OTHER PLANS FOR THE SCOPE OF CONSTRUCTION WORK.
2. THE MEASURES SPECIFIED HEREON ARE THE MINIMUM REQUIREMENTS FOR E&S CONTROL AND ARE SHOWN IN GENERAL SIZE AND LOCATION ONLY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THAT ALL E&S CONTROL MEASURES ARE CONFIGURED AND CONSTRUCTED IN A MANNER THAT WILL MINIMIZE EROSION OF SOILS AND PREVENT THE TRANSPORT OF SEDIMENTS AND OTHER POLLUTANTS TO ANY RESOURCE AREAS. ALL EROSION CONTROLS SHALL BE INSTALLED PRIOR TO ANY SITE WORK. CONTROLS SHOULD BE INSPECTED WEEKLY AND AFTER EACH RAINFALL. EXCAVATED MATERIAL SHOULD NOT BE DISPOSED OF IN THE WETLAND AREA. PROVIDE ADDITIONAL E&S MEASURES AS REQUIRED TO CONTROL EROSION AND SILTATION THROUGHOUT THE DURATION OF THE CONSTRUCTION AS CONDITIONS DICTATE AND/OR AS DIRECTED BY THE
OWNER OR THE ENGINEER.
3. MONITOR AND INSPECT ALL E&S MEASURES IN AN ONGOING MANNER THROUGHOUT THE WORK AND TAKE CORRECTIVE MEASURES, AS REQUIRED, TO MINIMIZE EROSION OF SOILS AND PREVENT THE TRANSPORT OF SEDIMENTS AND OTHER POLLUTANTS TO ANY RESOURCE AREAS.
4. ANY EROSION AND SEDIMENTATION MEASURE IMPLEMENTED BEYOND THAT SHOWN HEREON SHALL CONFORM TO APPLICABLE SECTIONS OF THE STATE OF CONNECTICUT'S 2024 “CONNECTICUT GUIDELINES FOR SOIL EROSION AND SEDIMENT CONTROL."
5. ANY STOCKPILED MATERIAL SHALL BE SUBJECT TO EROSION CONTROL MEASURES THAT INCLUDE A MINIMUM OF SILT FENCE OR HAY BALE BARRIER. COVER STOCKPILES IF SIGNIFICANT RAINFALL IS PREDICTED.
6. PROVIDE TEMPORARY SEEDING WITH MULCH ON ALL EXPOSED SOIL AREAS WHERE WORK WILL BE SUSPENDED FOR LONGER THAN 30 DAYS. APPLY SEED AND MULCH WITHIN THE FIRST 7 DAYS OF SUSPENDING WORK. WHEN SEEDING IS NOT POSSIBLE DUE TO SEASONAL WEATHER CONDITIONS OR OTHER FACTORS, PROVIDE TEMPORARY STRUCTURAL SOIL PROTECTION SUCH AS MULCH, WOODCHIPS, EROSION CONTROL MATTING, OR COMPOST.
7. ALL TEMPORARY SLOPES IN EXCESS OF 3 (HORIZONTAL) TO 1 (VERTICAL) SHALL BE STABILIZED WITH EROSION CONTROL MATTING OR APPROVED EQUIVALENT.
8. NO RUNOFF SHALL BE ALLOWED TO ENTER ANY STORMWATER SYSTEM OR EXIT THE SITE PRIOR TO TREATMENT FOR SEDIMENT REMOVAL.
9. THE CONTRACTOR SHALL MAINTAIN A CLEAN CONSTRUCTION SITE AND SHALL NOT ALLOW THE ACCUMULATION OF RUBBISH OR CONSTRUCTION DEBRIS. ALL TRASH SHALL BE CLEANED ON A DAILY BASIS AND THE SITE SHALL BE LEFT IN A NEAT CONDITION AT THE END OF EACH WORK DAY.
10. TAKE ALL NECESSARY PRECAUTIONS TO AVOID THE SPILLAGE OF FUEL OR OTHER POLLUTANTS AND ADHERE TO ALL APPLICABLE POLICIES AND REGULATIONS RELATED TO SPILL PREVENTION, CONTROL, AND RESPONSE.
11. FOR DUST CONTROL, PERIODICALLY MOISTEN EXPOSED SOIL SURFACES WITH WATER AND MAINTAIN ADEQUATE MOISTURE LEVELS.
12. SWEEP ADJACENT ROADWAYS IF MUD OR SOIL IS TRACKED ON TO THEM, OR AS DIRECTED BY THE ENGINEER.
13. ALL SEDIMENTATION AND EROSION CONTROL MEASURES SHALL BE INSTALLED BY THE PERMITTEE AND INSPECTED BY THE TOWN ENGINEER AND/OR THE WETLANDS ENFORCEMENT OFFICER / DULY AUTHORIZED AGENT; ADDITIONAL OR SUPPLEMENTAL CONTROLS MAY BE REQUIRED. THE PERMITTEE SHALL MAINTAIN THE CONTROLS DURING AND AFTER CONSTRUCTION AND REMOVE THEM UPON SITE STABILIZATION OF THE AFFECTED AREA.
14. AN ANTI-TRACKING APRON SHALL BE INSTALLED AT THE SITE ACCESS DRIVE AT A LOCATION APPROVED BY THE TOWN ENGINEER, WITH 6 INCHED OF CRUSHED STONE (SIZED 1 12" TO 3") UNDERLAIN WITH CONSTRUCTION FRAME SPREAD TO THE TRAVELED WIDTH AND 40 FEET IN LENGTH OR WITH
APRON MATS. THE APRON SHALL BE MAINTAINED AT ALL TIMES.
15. THE PERMITTEE AND THEIR CONTRACTOR SHALL MEET WITH AGENCY STAFF, INCLUDING BUT NOT LIMITED TO THE WETLANDS ENFORCEMENT OFFICER / DULY AUTHORIZED AGENT AND TOWN ENGINEER, TO REVIEW THE CONDITIONS OF THIS APPROVAL AND THE CONSTRUCTION PROGRAM TO BE
UTILIZED TO IMPLEMENT THE APPROVED REGULATED ACTIVITY.
16. THE WETLANDS ENFORCEMENT OFFICER / DULY AUTHORIZED AGENT SHALL BE NOTIFIED IN WRITING FORTY-EIGHT (48) HOURS PRIOR TO THE START OF CONSTRUCTION.
17. DURING THE DURATION OF THIS APPROVAL, THE CHAIRMAN OF THE AGENCY OR THE WETLANDS ENFORCEMENT OFFICER / DULY AUTHORIZED AGENT SHALL HAVE PERMISSION TO ENTER UPON THE SUBJECT PROPERTY AT REASONABLE TIMES FOR THE PURPOSE OF VIEWING AND INSPECTING
THE CONDUCT OF THE APPROVED REGULATED ACTIVITY.
18. NO WORK OTHER THAN MAINTENANCE OF SEDIMENT AND EROSION CONTROL SHALL BE PERFORMED DURING SIGNIFICANT RAINFALL OF ONE (1) INCH OR MORE WITHIN A TWENTY-FOUR (24) HOUR PERIOD. ALL WORK SHALL BE PERFORMED BETWEEN 8:00 AM AND 5:00 PM, MONDAY THROUGH FRIDAY. NO WORK MAY BE CONDUCTED ON LEGAL HOLIDAYS OR WEEKENDS WITHOUT THE EXPRESSED APPROVAL OF THE AGENCY.
19. UPON COMPLETION OF THE REGULATED ACTIVITY APPROVED HEREIN, THE PERMITTEE SHALL NOTIFY THE WETLANDS ENFORCEMENT OFFICER / DULY AUTHORIZED AGENT FOR A FINAL INSPECTION AND CONFIRMATION OF SATISFACTORY COMPLETION AND COMPLIANCE WITH THE APPROVED SITE PLANS AND ALL STANDARD AND SPECIAL SUPPLEMENTAL CONDITIONS, REQUIREMENTS AND MODIFICATIONS OF THIS APPROVAL.
FILTER INSERTS IN
DRAINAGE SYSTEM
WEEKLY & WITHIN 24 HOURS
AFTER STORM GENERATING A
DISCHARGE
MAINTENANCE MEASURES SCHEDULEE&S MEASURE
TEMPORARY E&S MEASURES MAINTENANCE SCHEDULE
HAY BALES/ SILT
FENCE BARRIER
WEEKLY & WITHIN 24 HOURS
AFTER STORM GENERATING A
DISCHARGE
CONSTRUCTION
ENTRANCE
WEEKLY
MOISTEN
EXPOSED SOILS
DAILY
CLEAN CATCH BASIN GRATE, REMOVE
SEDIMENT/DEBRIS FROM FILTER INSERTS
REPAIR/REPLACE WHEN FAILURE OBSERVED,
REMOVE SILT WHEN ACCUMULATION REACHES
APPROX. HALF HEIGHT OF BARRIER
SWEEP PAVED ROADWAY ADJACENT TO SITE
ENTRANCE AS NECESSARY, REFRESH STONE AS
NECESSARY, REMOVE SILTED GRAVEL
PERIODICALLY MOISTEN EXPOSED SOIL
SURFACES WITH WATER ON UNPAVED
TRAVELWAYS AND KEEP TRAVELWAYS DAMP
SUGGESTED CONSTRUCTION SEQUENCE:
1. CONDUCT A PRE-CONSTRUCTION MEETING WITH THE OWNER AND ENGINEER PRIOR TO ANY
CONSTRUCTION ACTIVITY.
2. INSTALL CONSTRUCTION ENTRANCE(S) AND PLACE CATCH BASIN FILTER INSERTS IN EXISTING
CATCH BASINS.
3. INSTALL PERIMETER E&S CONTROLS AND REQUEST PRE-CONSTRUCTION INSPECTION FROM THE
ENGINEER.
4. REMOVE EXISTING PAVEMENT.
5. PERFORM BULK EARTHWORK OPERATIONS.
6. BEGIN CONSTRUCTION OF BUILDING ADDITION FOUNDATION.
7. CONSTRUCT CURBING, WALKS, AND TOP COURSE OF BITUMINOUS PAVEMENT.
8. AT THE CONCLUSION OF CONSTRUCTION, COMPLETE THE INSTALLATION OF
POST-CONSTRUCTION SITE STABILIZATION MEASURES AS SHOWN ON THE DRAWINGS.
9. ONCE SITE IS FULLY STABILIZED REMOVE ALL EROSION CONTROLS.
SHEET NO.
PROFESSIONAL SEAL
21 Talcott Notch Road Farmington, CT 06032 friar.com 860.678.1291
CONSULTANT
DATE:
SCALE
PROJ. #:
DRAWN:
CHECKED:
Alfred Benesch & Company 200 Glastonbury Blvd., Suite 201 Glastonbury, Connecticut 06033 860-633-8341
WILSON
ELEMENTARY
SCHOOL ELEVATOR
ADDITION
STATE PROJECT NUMBER
235 Birch Street Waterbury, CT 06704
2022_049A
01/15/2026
151-0315 LUE
REVISIONS
NO. DATE DESCRIPTION
CONSTRUCTION FENCE (TYP.)
CONNECT TO EXISTING FENCE
HAY BALES (TYP.)
EXISTING CONCRETE WALK TO BE REMOVED
EXISTING PORTION OF BUILDING TO BE REMOVED
(REFER TO ARCHITECTURAL DRAWINGS)
CONSTRUCTION ENTRANCE
CONCRETE WASHOUT AREA
SILT FENCE BARRIER (SF)
N.T.S.
2'-6"
1'-6"
SECTIONELEVATION
*NOTE: POST SPACING AND EMBEDMENT VARIES
BASED ON THE FABRIC MANUFACTURER'S
REQUIREMENTS.
EXTRA STRENGTH SEDIMENT CONTROL FABRIC (AMOCO
PROPEX OR EQUAL)
10' MAX.*
100°
BURY FABRIC 6" BELOW
GROUND
GRADE
WOOD POST
SLOPE
CONSTRUCTION ENTRANCE (CE)
N.T.S.
6'
SILT FENCE
SURROUNDING
STOCKPILE 3:1 SLOPE MAX
TEMPORARY VEGETATIVE COVER TO BE
ESTABLISHED ON TOPSOIL STOCKPILE PER CT
DEEP E&S GUIDELINES
NOTE:
STOCKPILE IS NOT TO BE PLACED
ADJACENT TO SLOPES GREATER
THAN 3:1
TEMPORARY STOCKPILE (STK)
N.T.S.
NOTE: LOCATION TO BE DETERMINED IN THE FIELD BY THE CONSTRUCTION
ADMINISTRATOR
SECTION
PUBLIC R
OAD
PLAN
TREE BELT/SNOW SHELF - 7'-0" (TYP) 5'-0" (MIN.)
SIDEWALK - 5'-0" (MIN.)
2 1/2" (MIN.) - BIT. CONC. BINDER COURSE
CT DOT - NO. 3 ANGULAR
STONE PER M.01.01
4" MIN. DEPTH
FILTER FABRIC
COMPACTED SUBGRADE
CT DOT - NO.3 ANGULAR STONE
PER M.01.01 4" MIN. DEPTH
COMPACTED SUBGRADE
FILTER FABRIC
R=15' (TYP.) (MIN.)
25'-0" MIN.
50'-0" MIN.
12'-0" MIN.
CURB
HAY BALE BARRIER (HB)
N.T.S.
PROTECTED
WORK AREA
FLOW
TOP OF GROUND
18" (MIN.)
AREA
HAY BALES
BINDINGS TO BE PARALLEL
TO GROUND SURFACE
EMBED HAY BALES 4" INTO
GROUND. BACKFILL AND
COMPACT EXCAVATED FILL
ALONG HAY BALES
2"x11
2"x36" WOOD STAKE OR
STEEL POSTS WITH A MIN.
OF 0.5 POUNDS PER LINEAR
FOOT (2 PER HAY BALE)
NOTES:
1. HAY BALES SHALL BE MADE OF HAY OR STRAW WITH 40 POUND MIN. WEIGHT AND 120
POUND MAX. WEIGHT HELD TOGETHER BY TWINE OR WIRE.
2. PLACE HAY BALES ON CONTOUR AND WING THE LAST HAY BALES UP SLOPE SO THAT THE
TOP OF THE LAST SEVERAL HAY BALES ARE HIGHER THAN THE LINE OF HAY BALES.
3. DRIVE FIRST STAKE IN EACH BALE TOWARD THE PREVIOUSLY LAID BALE TO FORCE THEM
TOGETHER.
4. PUT ONE HAY BALE PERPENDICULAR ALONG HAY BALE BARRIER EACH 100 FEET.
STAKED HAY BALES
CROSS-SECTION
PLAN VIEW
FIELD VARIABLE
FI
EL
D V
AR
IA
BL
E
10' (MIN.)
OVERLAP
1'
NOTES:
1. CONSTRUCT WASHOUT AREA LARGE ENOUGH TO ENSURE MATERIALS WILL BE CONTAINED
WHERE WASTE CONCRETE CAN SOLIDIFY IN PLACE AND EXCESS WATER CAN SAFELY
EVAPORATE.
2. WASHOUT AREA SHALL BE LARGE ENOUGH TO RETAIN ALL LIQUID AND WASTE CONCRETE
MATERIALS FROM WASHOUT OPERATION.
3. WEEKLY INSPECTIONS OF WASHOUT AREAS SHALL BE CONDUCTED TO ASSESS THE
HOLDING CAPACITY AND FUNCTIONALITY OF THE WASHOUT AREA.
30-MIL PVC IMPERVIOUS
LINER
SEAL LINER; SEALANT NOT TO
PIERCE LINER
30-MIL PVC IMPERVIOUS
LINER
2"x11
2"x36" WOOD STAKE OR
STEEL POSTS WITH A MIN.
OF 0.5 POUNDS PER LINEAR
FOOT (2 PER HAY BALE)
30-MIL IMPERVIOUS LINER
BURY LINER 4"
TEMPORARY CONCRETE WASHOUT AREA (CWA)
N.T.S.
OR DRIVEN
POST
SCRIM SHEETING
CONSTRUCTION FENCE
N.T.S.
DEMOLITION & SITE
C1.0GSL
WGW
PREPARATION PLAN
1" = 10'
EXISTING CHAIN LINK FENCE TO REMAIN (REPLACE
OR RESET AS NECESSARY FOR CONSTRUCTION
ACCESS)
1" REBAR FOR BAG REMOVAL FROM INLET
(REBAR NOT INCLUDED)
OPTIONAL OVERFLOW
SILTSACK®
DUMP LOOPS (REBAR NOT INCLUDED)
FOAM INSERT
'SILTSACK' SEDIMENT CONTROL DEVICE, TERRAFIX GEOSYNTHETICS INC. TORONTO, ONTARIO, CA
WWW.TERRAFIXGEO.COM (OR EQUAL)
SILT SACK DETAIL (SS)
N.T.S.
2"x2"x36" WOOD STAKES PLACED 10' O.C.
FILTREXX FILTER SOXX OR APPROVED
EQUAL
SECTION
FILTER SOCK
N.T.S.
EROSION AND SEDIMENTATION CONTROL NARRATIVE:
PER STATE OF CONNECTICUT
ALL APPLICABLE PRACTICES RECOMMENDED BY THE 2024 CONNECTICUT GUIDELINES FOR SOIL EROSION AND SEDIMENT CONTROL AS AMENDED.
DESCRIPTION
THE PROJECT CONSISTS OF PROVIDING ADA ACCESSIBILITY TO THE BUILDING IN THE NORTHERN PARKING LOT AND CONSTRUCTING AN ELEVATOR ADDITION
ON THE SOUTHERN BUILDING WALL WITH A CONCRETE WALK FOR ACCESS.
DESIGN AND CRITERIA
NOTE: THE CONTRACTOR SHALL NAME ONE INDIVIDUAL AS HIS SEDIMENT AND EROSION CONTROL SUPERVISOR WHOSE PRIMARY RESPONSIBILITY WILL BE THE MAINTENANCE OF ALL ON-SITE EROSION CONTROL MEASURES. HE WILL KEEP A DAILY LOG OF HIS ACTIVITIES AND AN UPDATED SCHEDULE OF PROPOSED
CONSTRUCTION ACTIVITIES. THE LOG WILL BE MADE AVAILABLE TO INSPECTORS.
A. GEOTEXTILE SILT FENCE (SF) - SHALL BE NON-WOVEN MATERIAL, MINIMUM 36" HIGH AND FASTENED TO WOOD STAKES. SILT FENCE SHALL BE INSTALLED WITH END RUNS TURNED UP GRADE AT 45 DEGREES FOR A DISTANCE OF 10 FEET (SEE DETAIL THIS SHEET).
B. TEMPORARY SEEDING (TS)
1. CONTRACTOR SHALL SCARIFY THE SOIL TO A DEPTH OF 2" BEFORE APPLYING FERTILIZER, LIMESTONE AND SEED.
2. SEED MAY BE APPLIED BY HAND OR MECHANICALLY. SEED APPLICATION SHALL BE UNIFORM. SEED RATE SHALL BE IN ACCORDANCE WITH THE 2002 CONNECTICUT GUIDELINES FOR SOIL EROSION AND SEDIMENT CONTROL AS AMENDED (INCREASE SEEDING RATES BY 10% WHEN
HYDROSEEDING, LIMESTONE, FERTILIZER AND SEED MAY BE APPLIED IN SLURRY.)
3. CONTRACTOR SHALL MULCH AREA (MS) IMMEDIATELY FOLLOWING SEEDING. (NOTE: IN THE EVENT SEEDING OPERATIONS ARE NOT FEASIBLE DUE TO SEASONAL RESTRICTIONS OR EXTENDED INCLEMENT WEATHER PATTERNS, THE CONTRACTOR SHALL INSTALL AN EROSION CONTROL
BLANKET OVER EXPOSED SOILS.)
C. PERMANENT SEEDING (PS)
1. CONTRACTOR SHALL APPLY TOPSOIL AND FINE GRADE ALL AREAS BEFORE THE APPLICATION OF PERMANENT SEED. APPLY LIMESTONE AND
FERTILIZER AS NEEDED, IN ACCORDANCE WITH SOIL TESTS.
2. REMOVE ALL SURFACE STONES ½ INCH AND LARGER. REMOVE ALL OTHER DEBRIS AND RAKE SEED BED.
3. APPLY SEED WITHIN 7 DAYS AFTER ESTABLISHING FINAL GRADES. SEE PLANTING PLAN.
D. STRAW BALE BARRIER (HB) - SHALL BE MADE OF STRAW WITH 40 POUNDS MINIMUM WEIGHT AND 120 POUNDS MAXIMUM WEIGHT, HELD
TOGETHER BY TWINE OR WIRE. (SEE DETAIL THIS SHEET.)
E. CONSTRUCTION ENTRANCE (CE) - SHALL BE AN ANGULAR STONE PAD, A MINIMUM OF 12' WIDE AND 50' LONG. (SEE DETAIL THIS SHEET.)
F. EROSION CONTROL BLANKET (ECB) - EROSION MAT SHALL BE PLACED ON ALL EXPOSED CUT/FILL SLOPES STEEPER THAN 3:1 (INCLUDING SWALES & DITCHES) TO PROTECT AGAINST RAINFALL AND HOLD MOISTURE CONTENT TO ENHANCE VEGETATION GROWTH IN SEEDED AREAS. MAT (OR BLANKETS) SHALL BE STRAW OR STRAW/COCONUT FIBER COMBINATION SEWN TOGETHER WITH LIGHTWEIGHT NETTING. USE NORTH AMERICAN GREEN. S150 - SLOPES UP TO 3:1, SC150-SLOPES FROM 3:1 UP TO 2:1 OR GREATER. TEMPORARY HAY MULCH TO BE APPLIED TO AREAS LESS THAN 3:1 SLOPE AND ALL AREAS TO BE LEFT BARREN OVER THE WINTER, MULCH RATE TO BE 70 POUNDS/1000 S.F.
APPLICATION/GENERAL PROCEDURES
SOIL EROSION AND SEDIMENT CONTROL MEASURES WILL BE INSTALLED PRIOR TO ANY SITE DISTURBANCE, AND DEVELOPMENT WILL PROCEED ACCORDING TO A SPECIFIC CONSTRUCTION SEQUENCE. THE OBJECTIVE IS TO MAXIMIZE THE REDUCTION OF SEDIMENT-LADEN RUNOFF THROUGH IMPLEMENTATION OF CONVENTIONAL SOIL SEDIMENTATION AND EROSION CONTROL PRACTICES CURRENTLY RECOMMENDED BY THE 2024 CONNECTICUT GUIDELINES FOR SOIL
EROSION AND SEDIMENT CONTROL
A. EARTHWORK WILL BE SCHEDULED FOR PERIODS WHEN SOIL SATURATION IS LOW AND SOIL LOSS HAZARD IS AT A MINIMUM.
B. SUSPEND EARTHWORK FOR MAJOR STORM EVENTS AND IMPLEMENT ADDITIONAL SEDIMENTATION AND EROSION CONTROL MEASURES AS NECESSARY.
C. THERE SHALL BE NO CUTS OR FILL LEFT EXPOSED FOR LONGER THAN 30 DAYS. THE ESTABLISHED PROCEDURE OF TEMPORARILY SEEDING AND/OR COVER WITH EROSION PROTECTION (MAT OR STRAW) SHALL BE FOLLOWED TO INSURE MINIMAL SOIL LOSS.
D. THE DISCHARGE OF UNTREATED STORMWATER TO ANY ADJACENT ROADWAYS, DRAINAGE INLETS, OR PROPERTIES IS NOT ALLOWED.
SITE PREPARATION NOTES:
1. CONTRACTOR SHALL NOTIFY “CALL BEFORE YOU DIG” (1-800-922-4455) AND VERIFY UTILITY MARK-OUT WITH THE OWNER
PRIOR TO THE INITIATION OF ANY SITE DISTURBANCE.
2. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR VERIFICATION OF THE LOCATION AND NATURE OF ALL SUBSURFACE UTILITIES AT THE PROJECT WHICH MAY BE AFFECTED BY THE WORK. COORDINATE WITH RESPECTIVE UTILITY OWNERS AND
PERFORM VERIFICATION OF TYPE, LOCATION, AND INVERTS AS REQUIRED.
3. PROTECT ALL IMPROVEMENTS NOT INCLUDED WITHIN THE LIMITS OF WORK. ANY IMPROVEMENT WHICH IS DAMAGED SHALL
BE REPAIRED OR REPLACED IN-KIND TO THE OWNER'S SATISFACTION.
4. DURING DEMOLITION, PROTECT ALL ADJACENT CURBING, SIDEWALKS, RAMPS, ABOVE-GRADE AND BELOW-GRADE UTILITIES, DRAINAGE STRUCTURES, LIGHT BASES, AND OTHER IMPROVEMENTS POTENTIALLY AFFECTED BY THE WORK. CLEARLY DELINEATE THE LIMITS OF WORK AND MARK, BARRICADE, OR OTHERWISE IDENTIFY THOSE IMPROVEMENTS THAT ARE TO BE PROTECTED AND/OR AVOIDED. ANY IMPROVEMENT WHICH IS DAMAGED SHALL BE REPAIRED OR REPLACED IN-KIND TO THE
OWNER'S SATISFACTION.
5. THE LOCATIONS OF EXISTING SITE FEATURES AS SHOWN HAVE BEEN OBTAINED FROM MAPS, SURVEYS, FIELD INSPECTIONS, AND OTHER AVAILABLE INFORMATION. THEY MUST BE CONSIDERED APPROXIMATE BOTH TO LOCATION, SIZE, AND AS-BUILT CONDITION AND ARE PROVIDED FOR INFORMATIONAL PURPOSES ONLY. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR
DETERMINING ACTUAL FIELD CONDITIONS.
6. THE DIMENSIONS SHOWN ON THE PLANS, INCLUDING THE INTENDED DIMENSIONS OF THE WORK, MAY VARY FROM ACTUAL EXISTING CONDITIONS IN THE FIELD. THE CONTRACTOR SHALL TAKE APPROPRIATE MEASUREMENTS TO VERIFY ALL DIMENSIONS SHOWN ON THE DRAWINGS AS WELL AS OTHER DIMENSIONS HE MAY DEEM APPROPRIATE TO FACILITATE THE COMPLETION OF THE WORK. NOTIFY THE ENGINEER OF ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THE
CONTRACT DOCUMENTS BEFORE PROCEEDING WITH THAT PORTION OF THE WORK.
7. IMPLEMENTING WORKER SAFETY AND/OR HEALTH PROTOCOLS THAT ADDRESS COMPLIANCE WITH RULES, LAWS, AND REGULATIONS PERTAINING TO CONSTRUCTION SAFETY AND/OR THE POTENTIAL AND/OR ACTUAL RISK OF EXPOSURE TO SITE-SPECIFIC PHYSICAL OR CHEMICAL HAZARDS IS SOLELY THE RESPONSIBILITY OF THE CONTRACTOR.
8. PRIOR TO THE TERMINATION, ABANDONMENT, OR REMOVAL OF ANY UTILITY, VERIFY THAT APPLICABLE NOTIFICATIONS HAVE BEEN MADE TO THE UTILITY OWNER/OPERATOR AND THAT THE UTILITY HAS BEEN PROPERLY TERMINATED, CAPPED, OR
PLUGGED AS REQUIRED.
9. PROVIDE PAVEMENT SAWCUT AT THE EDGE OF EACH PAVEMENT REMOVAL AREA TO ESTABLISH A CLEAN EDGE WHERE NEW WORK WILL MEET EXISTING PAVEMENT. SAWCUT SHALL BE A MINIMUM OF 12 INCHES FROM EDGE OF PAVEMENT REMOVAL.
10. UNLESS OTHERWISE INDICATED, ALL DISTURBED AREAS SHALL BE RESTORED WITH SIX (6) INCHES OF LOAM, SEEDED, FERTILIZED, AND MULCHED. PROVIDE ADDITIONAL EROSION CONTROLS AS REQUIRED.
11. ALL SIDEWALK CLOSURES AND MEASURES FOR TEMPORARY PEDESTRIAN ACCESS, SIDEWALKS, CROSSINGS, AND BIKE
LANES SHALL MEET THE APPROVAL OF THE CITY OF WATERBURY.
SHEET NO.
PROFESSIONAL SEAL
21 Talcott Notch Road Farmington, CT 06032 friar.com 860.678.1291
CONSULTANT
DATE:
SCALE
PROJ. #:
DRAWN:
CHECKED:
Alfred Benesch & Company 200 Glastonbury Blvd., Suite 201 Glastonbury, Connecticut 06033 860-633-8341
WILSON
ELEMENTARY
SCHOOL ELEVATOR
ADDITION
STATE PROJECT NUMBER
235 Birch Street Waterbury, CT 06704
2022_049A
01/15/2026
151-0315 LUE
REVISIONS
NO. DATE DESCRIPTION
SEDIMENTATION
C1.1GSL
WGW
CONTROL NOTES
AS NOTED
EROSION &
& DETAILS
l xxx x x x x x x
WALL STREET
ELEVATOR ADDITION
CONCRETE SIDEWALK (TYP.)
LAWN / LANDSCAPED AREA
6" HDPE ROOF LEADER COLLECTOR PIPE (MAINTAIN MIN. 0.5% AND 2 FT OF COVER)
6"x6"x8" WYE
RL INV: 600.00
56' - 8" HDPE @ 7.14%
5' DIA. DRYWELL
TF: 598.75
INV: 596.00
BOT: 592.50
SG: 602.60
SG: 602.59
SG: 602.50SG: 602.63
SG: 602.52
SG: 602.50 SG: 602.40
SG: 602.40
SG: 602.48
SG: 602.54
SG: 602.44
SG: 602.47
SG: 602.57
SG: 602.78
SG: 602.75
FFE: 602.50
8' - 6" HDPE @ 5.00%
FOOTING DRAIN PUMP (SEE NOTES)
TF: 602.60± (M.F.G.)
INV: 600.19 (OUT)
6"X8"X8" WYE
INV: 599.79
REPLACE EXISTING FENCE WITH 4' BLACK VINYL FENCE
5' WIDE BLACK VINYL CHAIN LINK FENCE GATE
SCALE: 1 12" - 1'-0"
LIGHT DUTY CONCRETE SIDEWALK
COMPACTED SUBGRADE
REINFORCED CAST-IN-PLACE CONCRETE
W/ WWF (4 X 4 W2.9 X W2.9) IN FLAT
SHEETS CONTINUOUS THROUGH SCORE
JOINTS
DOWELED EXPANSION JOINT -'EJ' (TYP.)
W/ PREMOLDED JOINT FILLER AND
TOOLED EDGES
CONTROL JOINT W/ TOOLED EDGES W/ 1/4"
WIDE x 1" DEEP (TYP.)
FINISH GRADE
BROOM FINISH PERPENDICULAR TO
DIRECTION OF TRAVEL
NOTES:
1. PROVIDE 1/2" EXPANSION JOINTS WITH PERFORMED JOINT
FILLER AT 20'-0" O.C. MAX. OR AS INDICATED ON PLAN.
2. PROVIDE 1" DEEP TROWELED CONTROL JOINTS AT 5'-0" O.C.
OR AS INDICATED ON PLAN.
JOINT SEALER
2'-0" X 58" DIA. SMOOTH STEEL DOWEL
(2'-0" O.C.) WITH ONE END GREASED
FILTER FABRIC
COMPACTED SUBBASE
EXISTING DOOR
5" THICK 4,000 PSI CONCRETE PAD
NO. 4 HORZ. BAR, 16" O.C.
NO. 4 BAR, TOP AND BOTTOM
NO. 4 BAR, 16" O.C., BOTH WAYS
EXISTING BUILDING
FOUNDATION, CONNECT
TO FROST PAD WITH
DOWEL
4'-0"
GRANULAR FILL
NO. 4 HORZ. BAR, 16" O.C.
8"8"
8"
" M
IN
NO. 5 STAINLESS 12"
DOWELS 12" O.C. MAX
SEE CONCRETE WALK DETAIL
SCALE: NONE
FROST PAD
Va rie s
6"
Pi pe
1'
6"
PIPE O.D. PLUS
24" OR 3'-0" MIN.
GRAVEL FILL AS DIRECTED BY
ENGINEER WHEN UNSUITABLE
MATERIAL IS ENCOUNTERED
3/8" TO 3/4" CRUSHED STONE PLACED AND
COMPACTED IN 6" LAYERS. CRUSHED STONE
IN WET INSTALLATIONS
COMPLETE ENVELOPE OF FILTER FABRIC WITH
12" OVERLAP REQUIRED WHEN CRUSHED
STONE IS USED AS BEDDING MATERIAL,
FILTER FABRIC REQUIRED IN ROCK
CUT AS DIRECTED BY ENGINEER
GRAVEL BACKFILL PLACED AND COMPACTED
IN 12" LAYERS (UNDER PVMNTS.)
EXCAVATED MATERIAL (UNDER PLANTING)
WARNING
TAPE
VA
RI
ES
SEE LANDSCAPE SECTION
SEE
HARDSCAPE
SECTION
OR
1'- 6"
M
IN
ROOF LEADER
PVC ADAPTER (BLACK)
JOINT 1' MIN.
BLDG.
FND. WALL
PVC PIPE
ROOF LEADER BOOT
ADAPTER
HDPE
SCALE: NONE
1 5/8" TOP RAIL
DOME CAP
1 5/8" BRACE RAIL
AT CORNERS
TENSION BANDS 1'
O.C.
2 7/8" CORNER POST
4" MINIMUM
TERMINAL POST
STRETCHER BAR
1/4" X 3/4"
3/8" TRUSS W/TURNBUCKLES
(CORNERS)
CONC. FOOTING
9 GA. 2" FABRIC
2 3/8" LINE POST
3" BOX HINGES
1 5/8" BOTTOM RAIL
OR 7 GA. TENSION
WIRE
INSTALL 3" BELOW TOP OF GATE
SEE SITE PLAN
4' -0
4' CHAIN LINK FENCE & GATE
CONC. FOOTING
SHEET NO.
PROFESSIONAL SEAL
21 Talcott Notch Road Farmington, CT 06032 friar.com 860.678.1291
CONSULTANT
DATE:
SCALE
PROJ. #:
DRAWN:
CHECKED:
Alfred Benesch & Company 200 Glastonbury Blvd., Suite 201 Glastonbury, Connecticut 06033 860-633-8341
WILSON
ELEMENTARY
SCHOOL ELEVATOR
ADDITION
STATE PROJECT NUMBER
235 Birch Street Waterbury, CT 06704
2022_049A
01/15/2026
151-0315 LUE
REVISIONS
NO. DATE DESCRIPTION
ACCESSIBILITY NOTES:
1. SLOPES ALONG THE ACCESSIBLE ROUTE SHALL BE LESS THAN 1:20 (5%) AND THE CROSS SLOPES SHALL NOT EXCEED 1:50 (2%). CHANGES IN
LEVELS SHALL NOT BE GREATER THAN 14 INCH.
2. LANDINGS SHALL NOT HAVE A SLOPE GREATER THAN 1:50 (2%) IN ANY DIRECTION.
3. SLOPES WITHIN THE ACCESSIBLE PARKING SPACE SHALL NOT EXCEED 1:50 (2%) IN ANY DIRECTION.
LAYOUT NOTES:
1. NEW PAVEMENT TO MEET LINE & GRADE OF EXISTING PAVEMENTS.
2. ALL LINES AND DIMENSIONS ARE PARALLEL OR PERPENDICULAR TO THE LINES FROM WHICH THEY ARE MEASURED.
3. FIELD ADJUSTMENTS MUST BE APPROVED BY THE OWNER'S REPRESENTATIVE AND APPROPRIATE MUNICIPAL OFFICIALS PRIOR TO
CONSTRUCTION.
4. CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE VERTICAL AND HORIZONTAL POSITION OF EXISTING UTILITIES PRIOR TO CONSTRUCTION.
5. A DIGITAL CAD FILE CAN BE PROVIDED TO THE CONTRACTOR FOR THE LAYOUT OF SITE IMPROVEMENTS IN THE FIELD.
MATERIALS NOTES:
1. MATERIALS AND CONSTRUCTION PROCEDURES SHALL COMPLY WITH CT DOT FORM 819, THE CITY OF WATERBURY REGULATIONS AND THE
PROJECT MANUAL.
2. ALL LOCATIONS WHERE EXISTING CURBING, BITUMINOUS CONCRETE ROADWAY OR CONCRETE ROADWAY OR CONCRETE SIDEWALK ABUT NEW
CONSTRUCTION, THE EDGE OF THE EXISTING CURB OR PAVEMENT SHALL BE SAW CUT TO PROVIDE A CLEAN, SMOOTH EDGE. TACK COAT EXPOSED EDGES OF EXISTING CONCRETE PRIOR TO PLACEMENT OF NEW BITUMINOUS CONCRETE PAVEMENT.
3. MANUFACTURED ITEMS SHALL BE INSTALLED, CONNECTED AND CLEANED ACCORDING TO THE MANUFACTURERS DIRECTIONS.
4. EXPANSION AND SCORE JOINTS FOR NEW CONCRETE WALKS SHALL BLEND TO MATCH EXISTING PATTERNS. CONTRACTOR TO ARRANGE TIMELY
ON-SITE CONFERENCES WITH LANDSCAPE ARCHITECT TO APPROVE LAYOUT OF JOINT PATTERNS.
5. PROVIDE EXPANSION JOINTS FOR NEW CONCRETE PAVING AT ALL CURBS, TREE GRATES, BUILDING WALLS, SITE WALLS, STAIRS, LIGHT POLE
BASES, MANHOLES, GRATES/VAULTS, EXISTING CONCRETE PAVING, STOP LIGHTS, FIRE HYDRANTS AND ALL OTHER FIXED MATERIALS. MAXIMUM
DISTANCE BETWEEN EXPANSION JOINTS SHALL NOT EXCEED 20 FEET.
00 10' 20'
SCALE: 1" = 10'
LAWN
SCALE: NONE
DRYWELL
SCALE: NONE
2'-0"8'2'-0"
24"
12" OF CRUSHED
STONE BELOW
FINISHED GRADE
5' -0
24" DIA. CATCH BASIN GRATE. NEENAH R-3339-A, OR
APPROVED EQUIVALENT
FRAME AND GRATE TO FINISHED GRADE WITH BRICKS
OR REINFORCED CONCRETE GRADE RINGS. FRAME TO
BE SET IN FULL BED OF MORTAR
FILTER FABRIC - MIRAFI 140N
OR APPROVED EQUIVALENT
1 12" CRUSHED STONE
EXTRUDED BITUMINOUS CURBING
FINISH GRADE OF ADJACENT
PAVEMENT
BITUMINOUS TACK COAT
COMPACTED SUBBASE
COMPACTED SUBGRADE
COMPACTED BASE
PLANTING OR LAWN AREA
6" BITUMINOUS CURBING
SCALE: NONE
3" BITUMINOUS CONCRETE
SURFACE COURSE 2 EQ. LIFTS
WIDTH VARIES
2% (MAX.)
SLOPED TOWARD GUTTER
2" 11
2"
8" GRAVEL BASE
COMPACTED IN 4" LIFTS
3"
BITUMINOUS DRIVE AND SIDEWALK
SCALE: NONE
STORM TRENCH
SCALE: NONE
ROOF LEADER BOOT
SCALE: NONE
SITE PLAN
C2.0GSL
WGW
1" = 10'
PUMP STATION NOTES:
PUMP STATION TO BE DEFERRED DESIGN SUBMITTED FOR ENGINEER REVIEW AS A SHOP DRAWING. PUMP STATION TO BE DESIGNED BY UNITED CONCRETE PRODUCTS OR SIMILAR VENDOR. PACKAGE SHALL INCLUDE: WET WELL, VALVES, FLOATS, CONTROLS, REMOTE ACCESS, ETC.
DESIGN PARAMETERS:
· TDH: COORDINATE WITH MEP PLANS
· WET WELL SHALL HOLD MINIMUM 200 GALLONS BELOW THE INLET INVERT
· FORCE MAIN WILL BE APPROXIMATELY 57' AND WILL BE SIZE AS APPROPRIATE FOR THE PUMPS
· SYSTEM SHALL INCLUDE DUPLEX PUMPS ACCESSIBLE VIA A RAIL SYSTEM
· THE PUMP STATION SHALL HAVE A FRAME AND COVER THAT IS FLUSH WITH FINISHED GRADE
DEMOLITION LEGEND:
REMOVE COMPLETE WINDOW SYSTEM
REMOVE EXTERIOR MASONRY WALL CONSTRUCTION
REMOVE FLOORING AND WALL BASE TO THE EXTENT REQUIRED FOR
DEMOLITION OF WALL. WHERE NECESSARY, REMOVE TO FULL TILE
(NOT PARTIAL).
KEYED INTO PLAN
1. ANY DEMOLITION WORK ASSOCIATED WITH NEW WORK THAT IS NOT SPECIFICALLY NOTED
ON THIS PLAN SHALL BE THE RESPONSIBILITY OF THE DEMOLITION CONTRACTOR.
2. DEMOLISHED MATERIAL SHALL BE CONSIDERED TO BE THE PROPERTY OF THE CONTRACTOR
AND SHALL BE COMPLETELY REMOVED FROM THE JOB SITE.
3. SHUT OFF, CAP AND OTHERWISE PROTECT EXISTING PUBLIC UTILITY LINES IN ACCORDANCE
WITH THE REQUIREMENTS OF THE PUBLIC AGENCY HAVING JURISDICTION.
4. COMPLETELY REMOVE ITEMS SCHEDULED TO BE SO DEMOLISHED AND REMOVE, LEAVING
SURFACES CLEAN, SOLID AND READY TO RECEIVE NEW MATERIALS AND SPECIFIED
ELSEWHERE.
5. USE MEANS NECESSARY TO PREVENT DUST FROM BECOMING A NUISANCE TO THE USER.
6. THIS DRAWING DOES NOT DEPICT THE FULL EXTENT OF DEMOLITION. ADDITIONAL ITEMS
SCHEDULED FOR DEMOLITION MAY BE FOUND ON OTHER DRAWINGS. CONSTRUCTION
MANAGER IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK WITH ALL PARTIES
INVOLVED.
7. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL NATIONAL, STATE, LOCAL
CODES & ORDINANCES.
8. ALL EXISTING (FREESTANDING) FURNITURE ITEMS IN ALL ROOMS UNDER SCOPE OF WORK TO
BE REMOVED BY OWNER.
9. DEMOLITION CONTRACTOR MUST VERIFY LOCATIONS OF ALL EXISTING STRUCTURAL,
MECHANICAL, PLUMBING & ELECTRICAL ELEMENTS PRIOR TO START OF DEMOLITION.
10. REMOVE ALL INTERIOR WALLS SHOWN DOTTED, ALONG WITH ALL ASSOCIATED TACK
BOARDS, CHALK BOARDS, MARKER BOARDS, ETC. EXERCISE CAUTION SO AS NOT TO DISTURB
OR DAMAGE ADJACENT SURFACES SCHEDULED TO REMAIN.
11. NOT USED.
12. REMOVE ALL DOORS AND DOOR FRAMES SHOWN IN FULLY DEMOLISHED PARTITIONS ONLY,
UNLESS NOTED OTHERWISE.
13. REMOVE ALL RADIATION UNITS, H.V.A.C. RUNS, MECHANICAL UNITS, INFORMATION.
14. REMOVE ALL ELECTRICAL LIGHTING FIXTURES, ELECTRICAL RUNS, ASSOCIATED DEVICES.
REFER TO ELECTRICAL DEMOLITION DRAWINGS FOR RELATED INFORMATION.
15. REFER TO SITE PLANS FOR SITE DEMOLITION NOTES.
16. REFER TO ALL DRAWINGS FOR ADDITIONAL INFORMATION.
17. REMOVE ALL EXISTING FLOOR SYSTEMS I.E. VINYL TILE, SHEET VINYL, CERAMIC TILE, MASTIC, MUD SET, ETC. AT ALL AREAS WHERE A NEW FLOOR IS SCHEDULED. REF. FINISH PLANS &
SCHEDULE. PREP FLOORS TO RECEIVE NEW FINISHES.
18. ALL EXISTING LAY IN CEILING PANELS TO BE REMOVED BY THE ABATEMENT CONTRACTOR
WHERE NEW CEILINGS ARE SCHEDULED. REFER TO ASBESTOS ABATEMENT PLANS AND
REFLECTED CEILING PLANS.
19. REMOVE ALL CEILING GRIDS (CORRIDOR CEILING GRID TO BE REMOVED BY THE ABATEMENT
CONTRACTOR), GYPSUM CEILINGS AND SUSPENSION SYSTEMS AT ALL AREAS WHERE NEW
CEILINGS ARE SCHEDULED. REFER TO REFLECTED CEILING PLANS.
20. NOT USED.
21. ALL WINDOW SYSTEMS SCHEDULED FOR DEMOLITION TO BE REMOVED BY THE ABATEMENT
CONTRACTOR.
22. THE DEMOLITION PLANS ARE DIAGRAMMATIC AND INTENDED TO SHOW THE GENERAL
EXTENT OF THE WORK ONLY.
23. THE CONTRACTOR SHALL INCLUDE ALL DEMOLITION WORK REQUIRED TO ACCOMPLISH THE
INTENT OF THE PLANS AND SPECIFICATIONS.
24. ALL DEMOLISHED ITEMS SHALL BE REMOVED FROM BUILDING /SITE UNLESS OTHERWISE
NOTED. COORDINATE WITH OWNER FOR DELIVERY OF ITEMS NOTED TO REMAIN OWNERS
PROPERTY. THE PROJECT SITE/ BUILDING SHALL BE CLEANED OF DEBRIS ON A DAILY BASIS.
CONSTRUCTION MANAGER WILL COORDINATE AND INSTRUCT WHICH
25. CONTRACTOR SHALL BE RESPONSIBLE FOR SHORING AND SUPPORT (TEMPORARY OR
PERMANENT) FOR ALL PORTIONS OF CONSTRUCTION DURING DEMOLITION AND
CONSTRUCTION.
26. ALL ABANDONED MECHANICAL / ELECTRICAL / PLUMBING LINES SHALL BE CAPPED OFF
BEHIND FINISHES, UNLESS OTHERWISE NOTED. REFER TO MECHANICAL / ELECTRICAL /
PLUMBING DRAWINGS FOR ADDITIONAL DEMO. INFORMATION.
27. GENERAL TRADES CONTRACTOR SHALL SAWCUT ALL MASONRY OR CONCRETE OPENINGS
INDICATED. MASONRY SHALL BE TOOTHED IN AND / OR RETURNED TO FINISHED OPENING
ALL OPENINGS WHERE EXISTING CONSTRUCTION HAS BEEN REMOVED, AND WHICH ARE NOT
NOTED TO REMAIN, SHALL BE FILLED AND /OR PATCHED TO MATCH THE ADJACENT EXISTING
OR NEW FINISH, INCLUDING ANY FIRE RATINGS REQUIRED.
28. ALL AREAS OF FLOORS, WALLS AND CEILINGS DISTURBED BY DEMOLITION SHALL BE FILLED, PATCHED OR OTHERWISE REFINISHED TO MATCH EXISTING OR NEW FINISH AS DESIGNATED, INCLUDING ALL REQUIRED RATINGS.
29. CONTRACTOR MUST VERIFY LOCATIONS OF ALL EXISTING STRUCTURAL, MECHANICAL,
PLUMBING & ELECTRICAL ELEMENTS PRIOR TO START OF DEMOLITION.
30. COORDINATE DEMOLITION EFFORTS WITH ASBESTOS ABATEMENT SPECIFICATIONS.
31. EXISTING CONDITIONS SHALL BE STUDIED PRIOR TO BIDDING TO FAMILIARIZE YOURSELF
WITH THE BUILDING AND INTENTIONS OF THE FINAL WORK AND THE REQUIRED
DEMOLITION, INCLUDING ALL MECH., ELECT., PLUMB., TECH., STRUCTURAL AND GENERAL
CONSTRUCTION ITEMS REQUIRING REMOVAL.
32. NO ELECTRICAL, TECHNOLOGY WIRING OR PNEUMATIC LINES ARE TO BE ABANDONED IN
PLACE.
33. REFER TO SPECS FOR CUTTING & PATCHING, FLOOR PREP AND SELECTIVE DEMOLITION.
34. ALL DIMENSIONS ARE TO BE FIELD VERIFIED.
GENERAL DEMOLITION NOTES
WIDTH OF WINDOW UNIT AND WALL BELOW
9'-4" V.I.F.
1 2
D1.1
CORRIDOR
EX STAIR
B
CLASSROOM
1'-4" V.I.F.
CONCRETE WALL BELOW TO BE REMOVED
9'-1" V.I.F. 1'-4" V.I.F.
WINDOW UNIT WIDTH
11'-9" V.I.F.
D1.1
EX STAIR
B
OPEN SPACE
EX
CORRIDOR
1 2
DEMO EXISTING FINISH FLOOR 2'-0"
FROM SURFACE OF BASEMENT WALL
EXISTING SPIGOT AND
ASSOCIATED PIPING TO REMAIN
WIDTH OF WINDOW UNIT AND WALL BELOW
9'-4" V.I.F.
1 2
D1.1
Sim
EX STAIR
B
CLASSROOM
CORRIDOR
9'-4" V.I.F.
EXISTING WINDOW SYSTEM TO
BE REMOVED IN ITS ENTIRETY
EXISTING WALL SYSTEM TO BE REMOVED IN
INDICATED AREA, INCLUDING CMU BACK UP,
ANY PRESENT INSULATION, AND BRICK FACADE
2' -1
0" V
.I.
F.
8' -0
" V .I.
F.
FINISHED FLOOR
NOTE: PROTECT THE CEILING AND ALL
EXISTING ADJACENT PIPING DURING
DEMOLITION AND CONSTRUCTION.
9'-1" V.I.F.
5' -4
" V .I.
F.
4'
-2 " V
.I.
F.
EXISTING WINDOW SYSTEM TO
BE REMOVED IN ITS ENTIRETY
EXISTING WALL SYSTEM TO BE REMOVED IN INDICATED
AREA, INCLUDING POURED IN PLACE CONCRETE,
REINFORCEMENT, AND EXTERIOR INSULATION
FINISHED FLOOR
REMOVE EXISTING WALL BASE TO THE EXTENT
REQUIRED FOR DEMOLITION OF WALL.
NOTE: PROTECT THE CEILING AND ALL
EXISTING ADJACENT PIPING DURING
DEMOLITION AND CONSTRUCTION.11'-9" V.I.F.
SHEET NO.
PROFESSIONAL SEAL
21 Talcott Notch Road
Farmington, CT 06032 friar.com
860.678.1291
CONSULTANT
DATE:
SCALE
PROJ. #:
DRAWN:
CHECKED:
As indicated
D1.1
DEMOLITION PLANS
WOODROW WILSON
ELEMENTARY
SCHOOL ELEVATOR
ADDITION
STATE PROJECT NUMBER
235 BIRCH STREET
WATERBURY, CT 06704
BKH
JMY
2022-049A
1/15/2026
151-0316 LUE
SCALE: 1/4" = 1'-0"
SECOND FLOOR DEMOLITION PLAN
SCALE: 1/4" = 1'-0"
FIRST FLOOR DEMOLITION PLAN
SCALE: 1/4" = 1'-0"
THIRD FLOOR DEMOLITION PLAN
SCALE: 1/4" = 1'-0"
DEMO ELEVATION - SECOND AND THIRD FLOOR
SCALE: 1/4" = 1'-0"
DEMO ELEVATION - FIRST FLOOR
REVISIONS
A6.1
EX STAIR
B
CORRIDOR
A3.1
A3.1
A3.1
8'-8" VIF
4'-6" CLEAR
ELEVATOR
A6.1
VESTIBULE
A3.1
A3.1
A3.1
8'-8" VIF
EXISTING SPIGOT AND
ASSOCIATED PIPING TO REMAIN
ELEVATOR
A6.1
CORRIDOR
EX STAIR
B
CLASSROOM
A3.1
A3.1
A3.1
A2.1
A…
This is the start of the file's text. The full file is on GovTribe.