These are the bid documents for an elevator addition project at Driggs Elementary School in Waterbury, Connecticut, prepared by Friar Architecture in collaboration with structural engineer Michael Horton Associates, civil engineer Alfred Benesch & Company, and MEP/FP engineer Consulting Engineering Services. The project involves constructing a new elevator addition on the southern building wall with associated site work and ADA accessibility improvements in the northern parking lot. The scope includes structural work, masonry construction, roof installation, mechanical systems, electrical systems, fire protection, and interior finishes across three floor levels. The project is identified as State Project No. 151-0315, with a document issue date of February 6, 2026, and contract drawings prepared as of January 15, 2026. Existing building conditions include approximately 44,126 square feet of existing construction with 1,166 square feet being demolished and 170 square feet of new construction planned, totaling 45,462 square feet for the entire facility.
The design incorporates Connecticut State Building Code requirements (2021 International Building Code) with specifications for concrete foundations at 4,500 PSI strength, reinforced concrete slabs, 8-inch concrete masonry units with horizontal reinforcement, structural steel framing, roof systems with EPDM membrane, and integrated mechanical, plumbing, fire protection, and electrical systems. The elevator is specified as a new electric traction unit with associated hoistway construction, controls, and safety systems. Design loads include a roof snow load of 30 PSF minimum, wind design with 130 MPH ultimate wind speed, and seismic design per ASCE 7-16 standards. The construction documents include detailed drawings for foundations, floor slabs, roof assemblies, wall details, door and window schedules, reflected ceiling plans, finish schedules, and comprehensive MEP/electrical plans with controls, fire alarm integration, emergency communications, and lighting specifications. Site work includes erosion and sediment control measures, temporary stockpile areas, construction entrance details, and ADA-compliant parking provisions with modular retaining walls.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Wilson Elevator Bid Documents.pdf | ||
| RFP 8703 Addendum 1.pdf | ||
| Driggs Wilson Elevator Specs.pdf | ||
| ITB 8703- Wtby_Mar_2_26_solicitation_doc.pdf | ||
| RFP 8703 Addendum 2.pdf | ||
| RFP 8703 Addendum 2.pdf.crdownload | CRDOWNLOAD file | |
| ITB 8703- Wtby_Mar_30_26_solicitation_doc.pdf | ||
| Driggs Elevator Bid Documents.pdf.crdownload | CRDOWNLOAD file |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SITE LOCATION MAP
INDEX OF DRAWINGS
REBMUNTES
DRIGGS ELEMENTARY SCHOOL
77 WOODLAWN TERRACE
WATERBURY, CT
STATE PROJECT NO. 151-0315 LUE
1/15/2026
ISSUE FOR BID: 2/6/2026
ARCHITECT
CIVIL ENGINEER
ALFRED BENESCH & CO.
120 HEBRON AVENUE, FLOOR 2
GLASTONBURY, CT 06033
STRUCTURAL ENGINEER
MICHAEL HORTON ASSOC.
780 EAST MAIN STREET
BRANFORD, CT 06405
FRIAR ARCHITECTURE
21 TALCOTT NOTCH ROAD
FARMINGTON, CONNECTICUT
MAYOR
HONORABLE PAUL K PERNEREWSKI JR.
SUPERINTENDENT OF SCHOOLS
DR. DARREN SCHWARTZ
ELEVATOR ADDITION
MEP/FP ENGINEER
CONSULTING ENGINEERING SERVICES
811 MIDDLE STREET
MIDDLETOWN, CT 06457
REFERENCE
R1.1 REFERENCE SHEET
R1.2 EGRESS PLANS
CIVIL
C1.0 DEMOLITION & SITE PREPARATION PLAN
C2.0 SITE PLAN
DEMOLITION
D1.1 DEMOLITION FLOOR PLANS
ARCHITECTURE
A1.1 NEW WORK FLOOR PLANS
A2.1 ROOF PLAN & DETAILS
A3.1 BUILDING ELEVATIONS
A6.1 LARGE SCALE ELEVATOR & DETAILS
A7.1 PLAN & SECTION DETAILS
A8.1 WINDOW & DOOR ELEVATIONS, DETAILS, SCHEDULE
A9.1 REFLECTED CEILING
A12.1 FINISH PLAN & SCHEDULE
STRUCTURAL
S0.0 GENERAL NOTES
S1.0 NEW WORK FLOOR PLANS
S2.0 FOUNDATION, FLOOR AND ROOF SECTIONS
S3.0 TYPICAL DETAILS
FIRE PROTECTION
FP0.0 FIRE PROTECTION ABBERVIATIONS, NOTES & SYMBOLS
FPD1.1 FIRE PROTECTION DEMOLITION PLANS
FP1.1 FIRE PROTECTION NEW WORK PLANS
MECHANICAL
M0.0 MECHANICAL ABBERVIATIONS, NOTES & SYMBOLS
MD1.1 MECHANICAL DEMOLITION PLANS
M1.1 MECHANICAL NEW WORK PLANS
ELECTRICAL
E0.0 ELECTRICAL ABBERVIATIONS, NOTES & SYMBOLS
ED1.1 ELECTRICAL DEMOLITION PLANS
E1.1 ELECTRICAL POWER NEW WORK PLANS
E1.2 ELECTRICAL LIGHTING NEW WORK PLANS
E5.0 ELECTRICAL DETAILS
E6.0 ELECTRICAL SCHEDULES AND DIAGRAMS
MOUNTING HEIGHTS
ELECTRICAL MOUNTING HEIGHTS
ALL MOUNTING HEIGHTS TO BE COORDINATED WITH BLOCK COURSING AS OCCURS. CONSULT
ARCHITECT IF EXISTING CONDITIONS DIFFER
ALL DIMENSIONS ARE TO THE CENTER OF DEVICE UNLESS OTHERWISE NOTED.
SEE ELECTRICAL DRAWINGS FOR TYPES AND LOCATIONS.
RECEPTACLES : 18" A.F.F. ( AT LOCATIONS ABOVE CASEWORK, MOUNT BOTTOM OF RECEPTACLE
AT 2" ABOVE BACKSPLASH. AT LOCATIONS BELOW CASEWORK, MOUNT AT 24" A.F.F.)
WIREMOLD: 24" A.F.F. ( AT LOCATIONS ABOVE CASEWORK, MOUNT BOTTOM OF WIREMOLD AT 2"
ABOVE BACKSPLASH )
EXTERIOR RECEPTACLES: 24" A.F.G. (20" A.F.F.)
SWITCHES: 48" A.F.F.
BOILER EMERGENCY SWITCHES: 60" A.F.F.
DATA/PHONE OUTLETS: 18" A.F.F.
TV OUTLETS: 18" A.F.F. OR 18" BELOW FINISHED CEILING*
*FIELD VERIFY CEILING HEIGHTS WITH COORDINATION DRAWINGS
WALL PHONE: 48" A.F.F. TO CENTER OF EARPIECE
SECURITY KEYPAD: 48" A.F.F.
MICROPHONE WALL JACK: 48" A.F.F.
FIRE ALARM PULL STATION: 48" A.F.F.
FIRE ALARM VISUAL/AUDIO INDICATING UNITS: 6'-8" TO BOTTOM OF UNIT
AREA OF REFUGE CALL STATION: 48" A.F.F.
EMERGENCY SHUT-OFF SWITCH / PUSH BUTTON: 48" A.F.F.
EMERGENCY CALL SWITCH: 36" A.F.F.
EMERGENCY CALL BELL / LIGHT: +/- 7'-6" A.F.F., CENTER ABOVE DOOR
WALL MOUNTED EXIT SIGNS: 7'-6" A.F.F
WALL MOUNTED CLOCKS AND SPEAKERS: +/- 7'-6" A.F.F.
NOTES
CONSTRUCTION NOTES
GENERAL NOTES
ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL CODES AND ORDINANCES.
DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION OF DIMENSIONS FROM THE
ARCHITECT BEFORE CONTINUING WITH CONSTRUCTION.
CONTRACT DRAWINGS MAY VARY FROM ACTUAL FIELD CONDITIONS. CONTRACTOR SHALL CORRECT DIMENSIONS OF ALL
MATERIALS TO CARRY OUT OF THE INTENT OF THE CONTRACT DRAWINGS. VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS IN
FIELD BEFORE ORDERING ANY MATERIALS. CONTRACTOR SHALL NOTIFY ARCHITECT PROMPTLY OF ANY CRITICAL DISCREPANCIES
BEFORE PROCEEDING WITH WORK.
ALL NEW WORK SHALL BE IMPLEMENTED SO AS TO PROVIDE A SMOOTH AND CONTINUOUS SURFACE WITH ALL EXISTING
CONDITIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK NECESSARY TO ACHIEVE THIS REQUIREMENT, EVEN THROUGH
PROCEDURES ARE NOT DETAILED FOR EACH SPECIFIC CONDITION OR COMBINATION OF CONDITIONS. QUALITY OF
WORKMANSHIP, MATERIALS AND FINISHES SHALL BE EQUAL TO THE LEVEL ESTABLISHED FOR SIMILAR CONSTRUCTION, EXCEPT
WHERE EXISTING APPEARANCE IS TO BE MATCHED TO ACHIEVE CONTINUITY.
CUTTING AND PATCHING SHALL BE THE RESPONSIBILITY OF THE TRADE WHOSE WORK RESULTS IN THE NEED FOR CUTTING AND
PATCHING UNLESS A SPECIFIC CONTRACTOR IS CALLED OUT ON THE DRAWINGS. ALL HOLES LEFT BY REMOVING MECHANICAL, PLUMBING AND ELECTRICAL EQUIPMENT, ETC. SHALL BE PATCHED.
UNLESS OTHERWISE NOTED OR DIMENSIONED, NEW PARTITIONS SHALL BE CENTERED ON BUILDING COLUMN GRID OR WINDOW
MULLIONS.
CONTRACTOR SHALL PROVIDE WOOD BLOCKING AT WALLS AS REQUIRED TO SUPPORT SHELVES, CABINETS TV BRACKETS AND
RELATED ITEMS.
WHERE REQUIRED, SEISMIC BRACING SHALL BE PROVIDED AT SUSPENDED CEILINGS. SEE A9.X.
ALL EGRESS DOORS SHALL BE NON-LOCKING IN DIRECTION OF TRAVEL.
ALL PARTITIONS ARE TO EXTEND TO UNDERSIDE OF DECK ABOVE.
1.) DIMENSION CRITERIA
A. FROM FACE TO METAL STUD TO FACE OF METAL STUD
B. FROM FACE TO METAL STUD TO FACE OF CONCRETE MASONRY UNIT
C. FROM FACE TO CONCRETE MASONRY UNIT TO FACE OF CONCRETE MASONRY UNIT
3.) REFER TO SHEET R1.1 FOR WALL TYPES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ABBREVIATIONS
ABOVE FINISH FLOOR
ABOVE FINISH GRADE
ACOUSTIC TILE
AIR CONDITIONING
AIR HANDLING UNIT
ALTERNATE
ALUMINUM
ANCHOR, ANCHORAGE
ANCHOR BOLTS
ANGLE
ANODIZED
APPROVED
ARCHITECTURAL / ARCHITECT
ASBESTOS
ASPHALT
ASSEMBLY
ASSISTANT
AT
AUTOMATIC
BEAM
BEARING
BETWEEN
BEVEL / BEVELED
BITUMINOUS
BLOCK
BLOCKING
BOARD
BOTTOM OF
BOTTOM
BUILDING
BUILT-UP ROOF
CABINET UNIT HEATER
CAPACITY
CEILING
CEILING HEIGHT
CEMENT
CENTER
CENTERLINE
CERAMIC
CHALKBOARD
CHANNEL
CLOSET
COLUMN
CONFERENCE
CONTROL OR
CONSTRUCTION JOINT
CONTINUOUS
CONTRACTOR
CORRIDOR
COURSE / COURSES
DAMPPROOFING
DEGREE
DEMOLITION
DEPARTMENT
DETAIL
DIAMETER
DIMENSION
DISTANCE
DOOR
DOUBLE
DOUBLE HUNG
DOWN
DOWNSPOUT
DRAWING
DRINKING FOUNTAIN
EACH
ELECTRIC / ELECTRICAL ELECTRICAL
WATER COOLER
ELEVATION
ELEVATOR
EXISTING FIRE EXTINGUISHER
EMERGENCY
EQUAL
EQUIPMENT
EXISTING
EXISTING TO REMAIN
EXPANSION JOINT
EXTERIOR INSULATION
FINISH SYSTEM
FEET, FOOT
FINISH, FINISHED
FIRE DAMPER
FIRE EXTINGUISHER/FIRE BLANKET
CABINET
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER & BRACKET
FIRE RETARDANT
FIREPROOFING
FIXTURE
FLASHING
FLOOR DRAIN
FLOOR FINISH
FOOTING
FOUNDATION
FUME HOOD
FURNISH / FURNISHED
FURRED / FURRING
INCH OR INCHES
INCLUDE / INCLUDING
INFORMATION
INSIDE DIAMETER
INSULATION
INTERIOR
JOINT
KICK PLATE
LABORATORY
LAVATORY
LIGHTING
MACHINE
MAINTENANCE
MANUFACTURER
MARKER BOARD
MASONRY
MASONRY OPENING
MATERIAL
MAXIMUM
MECHANICAL
METAL
MEZZANINE
MINIMUM
MISCELLANEOUS
OFFICE
ON CENTER
OPPOSITE HAND
OPENING
OUTSIDE DIAMETER
PAINTED
PAIR
PAPER TOWEL DISPENSER
PERPENDICULAR
PLASTER
PLASTIC LAMINATE
PLATE
PLUMBING
PLYWOOD
PRECAST
PREFABRICATED
PRESSURE TREATED
PROJECT, PROJECTION POINT
QUANTITY
QUARRY TILE
RADIUS
RAIN WATER LEADER
RECEIVING
REFRIGERATOR
REINFORCED / REINFORCING
REQUIRED
REVISION / REVISED
RISER
ROOF DRAIN
ROOM
SANITARY NAPKIN DISPENSER
SANITARY NAPKIN
SCHEDULE
SCUPPER
SECTION
SEISMIC JOINT
SERVICE SINK
SHEET
SHOWER/EYEWASH
SIMILAR
SOAP DISPENSER
SOUND TRANSMISSION CLASS
SPECIFICATIONS
SPLASH BLOCK
SQUARE
SQUARE INCH (S)
SQUARE YARD (S)
SQUARE FEET (FOOT)
STAINLESS STEEL
STANDARD
STEEL
STORAGE
STRUCTURAL
STRUCTURAL GLAZED
FACING TILE
STRUCTURAL STEEL
SUSPEND, SUSPENSION
SURFACE
SYSTEM
TACKBOARD
TELEPHONE
TEMPERATURE / TEMPORARY
TOUNGE & GROOVE
THRESHOLD
THICK
TOILET
TOP OF
TREAD
TYPICAL
UNDERWRITER'S LABS
UNIT HEATER
UNIT VENTILATOR
UNLESS NOTED OTHERWISE
URINAL
VENT THROUGH ROOF
VERIFY IN FIELD
VERTICAL
VINYL ASBESTOS TILE
VINYL COMPOSITION TILE
WATER CLOSET
WATERPROOFING
WELDED WIRE FABRIC
WEIGHT
WHITE BOARD
WITH
WOOD
A.F.F.
A.F.G.
AC.,A.C.T.
A.C.
A.H.U.
ALT.
ALUM.
ANCH.
ABL
ANG
ANOD.
APPD.
ARCH.
ASB.
ASPH.
ASSY.
ASST
AUTO.
BM.
BRG.
BET.
BEV.
BIT.
BLK.
BLKG.
BD.
B/O
BTM.
BLDG.
B.U.R.
C.U.H.
CAP.
CLG.
CLG.HGT.
CEM.
CTR.
CL
CT
C.BD.
CH.
CLOS.
COL
CONF.
C.J.
CONT.
CONTR.
CORR.
CRS.
DAMPR.
DEG.
DEMO.
DEPT.
DET.
DIA.
DIM.
DIST.
DR.
DBL.
D.H.
DN.
D.S.
DWG.
D.F.
EA.
ELEC.
EWC.
EL.
ELEV.
EXFE
EMG.
EQ.
EQUIP.
EXIST.
ETR.
E.J.
EXT. EIFS.
FT.
FIN.
FD.
FEB
FEC
FE
FR.
FPRFG.
FIXT.
FLASH. FL.
FD.
FLR. FIN.
FTG.
FDN.
F.H.
FURN.
FURR
IN.
INCL.
INFO.
I.D.
INSUL.
INT.
JT.
KP.
LAB.
LAV.
LTG.
MACH.
MAINT.
MFR.
MBD.
MAS.
M.O.
MATL.
MAX.
MECH.
MET.
MEZZ.
MIN.
MISC.
OFF.
O.C.
O.H.
OPG.
O.D.
PTD.
PR.
P.T.D.
PERP.
PLAS.
P.LAM.
PL.
PLBG.
PLYWD.
P.C.
PREFAB.
PROJ. PT.
P.T.
QTY.
Q.T.
RAD.
RWL.
RECV.
REF.
REINF.
REQ'D.
REV.
R
R.D.
RM.
S.N.D.
S.N.R.
SCHED.
SC.
SECT.
S.J.
S.S.
SHT.
S/E
SIM.
S.D.
S.T.C.
SPEC.
S.B.
SQ.
SQ.IN.
SQ.YD.
S.F.
ST. STL.
STD.
STL.
STOR.
STRUCT.
SGFT.
STRUCT. STL.
SUSP.
SURF.
SYS.
TBD.
TEL.
TEMP.
T & G
THLD.
THK.
TLT
T/O
T.
TYP.
U.L.
U.H.
U.V.
U.N.O.
UR.
V.T.R.
V.I.F.
VERT.
V.A.T.
V.C.T.
W.C.
W.P.
W.W.F.
WT.
WBD.
W/
WD.
INTERIOR ABBREVIATIONS
ACID
AWP
BB
BC
C
CC
CMT
CTB
CTR
CWT
DCPL
DC
DST
DW
EM
EG
EP
EPR
ER
ERS
ET
ETR
FEB
FEC
FE
FC
FLAM
GBB
GC
GT
HB
HPWP
HR
ICE
INTBD
L
LK
LRF
LS
LT
LVT
MC
MBD
MCIC
MP
MS
MW
P
ACID CABINET
ACOUSTICAL WALL PANEL
BUTCHER BLOCK COUNTERTOP
BASE CABINET
CARPET (TILE AND/OR BROADLOOM)
CUBICAL CURTAIN
CEMENTITIOUS TOPPING
CERAMIC TILE BASE
COUNTER
CERAMIC WALL TILE
DECORATIVE WALL PANEL
DISPLAY CASE
DISTILLER
DISHWASHER (GLASSWARE)
ENTRY MAT
ENTRY GRILLE
EPOXY PAINT
EXPLOSION PROOF REFRIGERATOR
EPOXY RESIN FLOORING
EPOXY RESIN COUNTERTOP
EPOXY TERRAZZO
EXISTING TO REMAIN
FIRE EXTINGUISHER/FIRE BLANKET CABINET
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER & BRACKET
FOLIO CABINET
FLAMMABLE CABINET
GLAZED BLOCK BASE
GOGGLE CABINET
GROUT
HORIZONTAL BLINDS
HIGH PRESSURE WALL PANEL
HANDRAILS, RAILINGS & STRINGERS
ICE MAKER
INTELLIGENT BOARD
LINOLEUM
LOCKER
LUXURY RESILIENT FLOORING
LINOLEUM SHEET FLOORING
LINOLEUM TILE
LUXURY VINYL TILE
METAL CABINETRY
MARKERBOARD
MULTI-COLORED INTERIOR COATING
METAL PANEL
MOTORIZED SHADE
MICROWAVE
PAINT
PC
PCF
PJS
PL
PR
PT
PTD
QT
QTB
RB
REF
RT
RST
SC
STCT
STGC
SF
SF
SS
SSG
STS
SV
SVS
SVT
TBD
TF
TS
UC
UCR
V
VB
VCT
VS MBD
VT
VWC
WB
WC
WD
WDC
WDT
WDU
WM
WP
WS
PRIVACY CURTAIN
PAINTED CONCRETE FLOOR
PROJECTION SCREEN
PLASTIC LAMINATE
PHENOLIC RESIN COUNTERTOPS
PORCELAIN TILE
PAPER TOWEL DISPENSER
QUARRY TILE
QUARRY TILE BASE
RUBBER BASE
REFRIGERATOR
RUBBER TILE
RUBBER STAIR TREAD/RISERS
SEALED CONCRETE
STAINED CONCRETE
STAGE CURTAIN
EMERGENCY SHOWER/EYEWASH
SPORTS FLOOR
SOLID SURFACE
SAFETY SHEET GOOD
STAINLESS STEEL COUNTERTOP
SHEET VINYL FLOORING
SOLID VINYL SHEET GOOD
SOLD VINYL TILE
TACKBOARD
TERRAZZO FLOORING
TACK STRIP
UPPER WALL CABINET
UNDER COUNTER REFRIGERATOR
VENEER CABINETRY
VINYL BASE
VINYL COMPOSITE TILE
VERTICAL SLIDING WHITEBOARD
VINYL TILE
VINYL WALL COVERING
WALL BASE
WALL COVERING
WOOD
WOOD CASEWORK
WOOD TALL CABINETS
WOOD UPPER CABINETS
WALK-OFF MAT
WALL PROTECTION/PADDING
WINDOW SHADES
BUILDING SECTION
ARCHITECTURAL SYMBOLS
WALL SECTION
COLUMN CENTERLINE
DETAIL DESIGNATION, PLAN DETAIL,
LARGE SCALE PLANS
INTERIOR ELEVATIONS
CASEWORK ELEVATIONS
CEILING DESIGNATION
ROOM NUMBER
DOOR NUMBER
WINDOW DESIGNATION
DEMOLITION TAG
WALL TYPES
PHOTO LOCATION
REVISION NUMBER
DATUM / ELEVATION / LEVEL LINE
EXISTING CONSTRUCTION TO REMAIN
NEW STUD CONSTRUCTION
NEW CONCRETE BLOCK
NEW FACE BRICK
SOFFITS / OVERHANG ABOVE
THIS REPRESENTS A 30"X48" ADA
WHEELCHAIR CLEARANCE. IN ADDITION IT
REPRESENTS A 30" CLEAR WIDTH.
ACCESSIBLE ELEMENT
AREA OF REFUGE WHEELCHAIR SPACE ACCESS.
CLEAR FLOOR SPACE ASSEMBLY WHEELCHAIR
SEAT 30"x48" CLEAR FLOOR SPACE
CORNER GUARD
SECTION NUMBER
SHEET NUMBER
SECTION NUMBER
SHEET NUMBER
LETTERS (HORIZ.)
SHEET NUMBER
NUMBERS (VERT.)
DETAIL NUMBER
SHEET NUMBER
ELEVATION NUMBER
ELEVATION NUMBER
CEILING TYPE (LETTER)
CEILING HEIGHT (NUMBER)
NUMBER
NUMBER/TYPE
LETTER/TYPE
NUMBER
NUMBER
PHOTO NUMBER
NUMBER
MIN.
30" CLR
M
IN
C
LR
METAL (SMALL)
METAL LATH
MARBLE
GYPSUM BOARD
GRAVEL
GLAZING
GLAZED BRICK
GLASS BLOCK
FIRE BRICK
FINISHED WOOD
FACE GRAIN
FACE BRICK
FLAT METAL PANEL
SLATE, FLAGGING,
SOAPSTONE
METAL PANEL
CORRUGATED
GLASS
CERAMIC TILE
CONCRETE BLOCK
BRICK
ELEVATIONS
TERRAZZO
TERRA-COTTA
STRUCT. GLAZED
FACING TILEEARTH
CONCRETE
C.M.U.
STRUCTURAL CLAY
STEEL
SLATE, FLAGGING,
SOAPSTONE
CERAMIC TILE
CAST STONE
CARPET
SHEATHING INSUL.
RUBBLE
ROUGH WOOD
(INTERRUPTED)
BRASS OR BRONZE
BITUMINOUS
BATT INSULATION
ROUGH WOOD
(CONTINUOUS)
RIGID INSULATION
PLYWOOD ( SMALL)
ACOUSTICAL TILE PLASTER
ALUMINUM
ARCHITECTURAL MATERIALS
TYPICAL NOTES
1. ALL ACOUSTICAL WALL ASSEMBLIES ARE TO BE SEALED TOP AND BOTTOM, TERMINATE
AT THE UNDERSIDE OF THE FLOOR ABOVE OR THE ROOF ABOVE, TYPICAL.
2. ALL FIRE RATED WALLS ARE TO BE SEALED TOP AND BOTTOM, TERMINATE AT THE
UNDERSIDE OF THE FLOOR ABOVE OR THE ROOF ABOVE, TYPICAL.
3. ALL INTERIOR WALLS ARE TO BE SEALED TOP AND BOTTOM, TERMINATE AT THE
UNDERSIDE OF THE FLOOR ABOVE OR THE ROOF ABOVE, TYPICAL.
4. FOR BOND BEAMS, REINFORCING AND OR SHEAR WALLS, REFER TO STRUCTURAL
DRAWINGS, TYPICAL.
5. SEAL ALL THRU WALL PENETRATIONS TO MAINTAIN CONSISTENT FIRE, SMOKE AND STC
RATINGS. ALL PENETRATIONS INCLUDING BUT NOT LIMITED TO ALL ELECTRICAL
(CONDUITS & BOXES), MECHANICAL (DUCTS, PIPES), PLUMBING AND FIRE PROTECTION
PIPING. SEE WALL TYPES FOR ASSOCIATED RATINGS AND SEE SEALANT SPECIFICATIONS
FOR TYPES.
6. CONTRACTOR TO VERIFY THAT ALL FIRE ASSEMBLIES ARE CONSTRUCTED IN
ACCORDANCE WITH APPROVED LISTED ASSEMBLIES PER CURRENT U.L. FIRE
RESISTANCE DIRECTORY.
7. MOISTURE RESISTANT GYPSUM BOARD IS TO BE USED IN LIEU OF ABUSE RESISTANT
GYPSUM BOARD ON ALL INTERIOR FACES OF TOILET ROOMS.
8. ALL INTERIOR GYPSUM WALL PARTITIONS TO HAVE ABUSE RESISTANT GYPSUM
BOARD CONSTRUCTION EXTENDING 1'-0" ABOVE CEILING HEIGHT. STANDARD
GYPSUM BOARD SHALL BE USED ABOVE CEILING AND EXTENDING TO DECK ABOVE.
EXCEPT WHERE NOTED OTHERWISE.
9. NOT ALL WALL TYPES SHOWN ARE USED IN PROJECT. REFER TO FLOOR PLAN.
A
EXTERIOR
3" RIGID INSULATION
1 3/4" AIR SPACE
4" BRICK
INTERIOR
SELF ADHERING AIR VAPOR BARRIER
8" CONCRETE MASONRY UNIT, HORIZONTAL
REINFORCEMENT EVERY 16" VERTICALLY
EXTERIOR WALL TYPES
8" CONCRETE MASONRY UNIT,
HORIZONTAL REINFORCEMENT EVERY
16" VERTICALLYSTC = 42
INTERIOR WALL TYPES
1A
8" CONCRETE MASONRY UNIT
7/8" METAL STUD FURRING AND 5/8" GYPSUM WALLBOARD
3-5/8" METAL STUD @ 16" O.C.
5/8" ABUSE RESISTANT GYP. (BOTH
SIDES) EXTEND TO MINIMUM 6" ABOVE
FINISHED CEILING
2A 1 HOUR FIRE RATED, GYP BOTH SIDES TO DECK, BATT INSULATION
U.L. DESIGN #U419
2B 3-5/8" METAL STUD @ 16" O.C.
5/8" ABUSE RESISTANT GYP. (ONE SIDE ONLY)
EXTEND TO MINIMUM 6" ABOVE FINISHED CEILING
1-5/8" METAL STUD @ 16" O.C.
5/8" ABUSE RESISTANT GYP. (ONE SIDE)
EXTEND TO MINIMUM 6" ABOVE
FINISHED CEILING
EXTERIOR
2" RIGID INSULATION
2" METAL Z-GIRT @ 16" O.C.
1" METAL PANEL SYSTEM, HORIZONTAL ORIENTATION
INTERIOR
SELF ADHERING AIR VAPOR BARRIER
BATT INSULATION
1/2" EXTERIOR GRADE PLYWOOD SHEATHING
6" METAL STUD @ 16" O.C.
5/8" ABUSE RESISTANT GYP.
B
-1 /4
SHEET NO.
PROFESSIONAL SEAL
21 Talcott Notch Road
Farmington, CT 06032 friar.com
860.678.1291
CONSULTANT
DATE:
SCALE
PROJ. #:
DRAWN:
CHECKED:
3/4" = 1'-0"
R1.1
REFERENCE SHEET
DRIGGS
ELEMENTARY
SCHOOL ELEVATOR
ADDITION
STATE PROJECT NUMBER
77 Woodlawn Terrace
Waterbury, CT 06710
BKH
JMY
2022_049A
1/15/2026
151-0315 LUE
Date of Original Construction
1. GROUP CLASSIFICATION
(Primary) (Incidental)
Renovation
EDUCATION (E)
20261965
CODE INFORMATION
3. CODES TO WHICH THIS PROJECT WAS DESIGNED Dated:
2. SPRINKLER PROTECTION
EXISTING UNRENOVATED CONSTRUCTION
5. BUILDING AREAS FOR GRANT CALCULATIONS (ENTIRE FACILITY)
NoYes4. THRESHOLD BUILDING CONDITIONS X
EXISTING RENOVATED CONSTRUCTION
TOTAL EXISTING CONSTRUCTION
EXISTING BEING DEMOLISHED
TOTAL NEW CONSTRUCTION
TOTAL FACILITY
44,126 SF
Limited Area
Entire Building
X
1,166 SF
45,292 SF
170 SF
45,462 SF
2021 International Building Code *
2021 International Mechanical Code *
2021 International Plumbing Code *
2021 International Energy Conservation Code *
2019 Installation of Sprinkler Systems (NFPA 13)
2021 Life Safety Code (NFPA 101) *
2021 Fire Code (NFPA 1) *
2021 International Residential Code *
2021 International Existing Building Code *
2017 Accessible and Usable Buildings and Facilities (ICC A117.1-2017)*
2020 National Electrical Code (NFPA 70)*
2021 International Fire Code *
2021 International Swimming Pool & Spa Code *
* With Connecticut Amendments and General Statute requirements
REVISIONS
NO. DATE DESCRIPTION
2/6/2026 ISSUE FOR BID
DIRECTION OF TRAVEL
WITH ACCUMULATED OCCUPANCY LOAD
MAXIMUM TRAVEL DISTANCE
FROM FURTHEST POINT
NOTES:
ROOM NUMBER
OCCUPANCY LOAD FACTOR
AREA IN SQUARE FEET
EXIT CAPACITY
ROOM OCCUPANCY LOAD
MAXIMUM ALLOWABLE EGRESS OCCUPANCY OF DOOR OR STAIR
ACTUAL EGRESS OCCUPANCY OF DOOR OR STAIR
EGRESS PLAN LEGEND
2 HOUR RATED WALL
(TIGHT TO DECK ABOVE)
1 HOUR RATED WALL
(TIGHT TO DECK ABOVE)
SMOKE PARTITION
(TIGHT TO DECK ABOVE)
BUILDING PROPERTY LINE
BR Balance Exit. Minimum number of exits required per 1018.0
BD Balance Exit. Exit required due to dead end corridor
BA Balance Exit. Exit as required for Assembly space.
BT Balance Exit. Exit as required due to travel distance.
1. A VALUE OF 0.2 INCHES OF WIDTH PER OCCUPANT HAS BEEN USED TO CALCULATE DOOR
AND CORRIDOR EGRESS CAPACITY. IN ALL CASES, THE ACTUAL CLEAR OPENING OF THE
DOOR AND ACTUAL CLEAR WIDTH OF THE CORRIDOR IS USED.
2. A VALUE OF 0.3 INCHES OF WIDTH PER OCCUPANT HAS BEEN USED TO CALCULATE
STAIRWAY EGRESS CAPACITY. IN ALL CASES, THE ACTUAL CLEAR WIDTH BETWEEN
STRINGERS IS USED.
=664 3
=666 34
=254 1
=671 34 20 =882 45
=170 1
=139 1 300 =160 1
=714 15
=442
=184 1
=655 3
=450 9
=109 1
=600 30
=604 4
=646
=2101 15
=2505 168
=167 1
=603 31
CORRIDOR
CORRIDOR
STORAGE
BOILER ROOM
COURTYARD
CORRIDOR
CLASSROOM
STORAGE
CLASSROOM
STAIR STAIR
CORRIDOR
CLASSROOM
STORAGE
STORAGE
ELEC. ROOM
LOCKER ROOM
STORAGE
STORAGE
MUSIC STORAGE
MUSIC
CLASSROOM
STORAGE
CLASSROOM
KITCHEN
HEALTH
RESOURCE
CENTER
CAFETERIA
LOBBY
STORAGE
PASSAGEWAY
CLASSROOM
STORAGE
TOILET ROOM
=324 2
TLT ROOM
TLT ROOM
=122 1
=41
LOBBY
CORRIDOR
OFFICE CLASSROOM CLASSROOM CLASSROOM CLASSROOM
PASSAGE
CLASSROOM
OFFICE
CLASSROOM
OFFICE
CLASSROOMCLASSROOMCLASSROOMCLASSROOM
PASSAGE
LOBBY
CLASSROOM
PASSAGE
STAIR
CORRIDOR
CORRIDOR
STAIR
STAGE FOYER
GYMNASIUM
STORAGE STAIR
STORAGE
STAIR
=340 3
=660 34
=679 34
=648 33 20 =651 33
=637 32
=252 2
=599 30
=200
=629
=602
=613
20=628 32
=634 32
=659 44
=4267 854
=149 1
=187 1
TEACHER
WORK ROOM
=89 2
CORRIDOR
=725 5
=692 35
=117 1
=699 35
=329 17
=358 18
=703 36
=140 7
=701
=704 36
=231
=643
20=292
=700
=685
=700
=236
=679 34
OFFICE
CLASSROOM CLASSROOM
OFFICE
CLASSROOM CLASSROOM CLASSROOM CLASSROOM
CLASSROOM
OFFICE
CLASSROOM
READING
ROOMCLASSROOMCLASSROOM
CLASSROOM
OFFICE
CLASSROOM
CORRIDOR
CORRIDOR
STAIRSTAIR
SPEECH
LOBBY
CORRIDOR
STORAGE
TLT ROOM TLT ROOM
=86 1
5240 52
SHEET NO.
PROFESSIONAL SEAL
21 Talcott Notch Road
Farmington, CT 06032 friar.com
860.678.1291
CONSULTANT
DATE:
SCALE
PROJ. #:
DRAWN:
CHECKED:
As indicated
R1.2
EGRESS PLANS
DRIGGS
ELEMENTARY
SCHOOL ELEVATOR
ADDITION
STATE PROJECT NUMBER
77 Woodlawn Terrace
Waterbury, CT 06710
BKH
JMY
2022_049A
1/15/2026
151-0315 LUE
SCALE: 1/16" = 1'-0"
FIRST FLOOR EGRESS PLAN
SCALE: 1/16" = 1'-0"
SECOND FLOOR EGRESS PLAN
SCALE: 1/16" = 1'-0"
THIRD FLOOR EGRESS PLAN
REVISIONS
l xxxxxxxxxxxxxxxxxx x x x x x x x x x x x x
IRVING STREET
SF SF SF SF
SF SF
SFSF
STK
CWA
HAY BALE BARRIER
CATCH BASIN FILTER INSERT
TEMPORARY CONCRETE WASHOUT
SF
SF
SF
SF
SF
SF
TEMPORARY STOCKPILE
EXISTING PROPERTY LINES
SILT FENCE BARRIERSF SF SF SF
CONSTRUCTION ENTRANCE STK
CWA
CE
BITUMINOUS PAVEMENT DEMOLITION
FENCE/WALL DEMOLITION
SITE ITEM TO BE REMOVED
TREE PROTECTIONP
BUILDING DEMOLITION
CONSTRUCTION FENCE
LIMIT OF DISTURBANCELOD LOD
00 10' 20'
SCALE: 1" = 10'
DEMOLITION AND EROSION CONTROL LEGEND
EROSION AND SEDIMENT CONTROL NOTES:
1. THIS PLAN IS FOR EROSION AND SEDIMENTATION (E&S) CONTROL ONLY. SEE OTHER PLANS FOR THE SCOPE OF CONSTRUCTION WORK.
2. THE MEASURES SPECIFIED HEREON ARE THE MINIMUM REQUIREMENTS FOR E&S CONTROL AND ARE SHOWN IN GENERAL SIZE AND LOCATION ONLY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THAT ALL E&S CONTROL MEASURES ARE CONFIGURED AND CONSTRUCTED IN A MANNER THAT WILL MINIMIZE EROSION OF SOILS AND PREVENT THE TRANSPORT OF SEDIMENTS AND OTHER POLLUTANTS TO ANY RESOURCE AREAS. ALL EROSION CONTROLS SHALL BE INSTALLED PRIOR TO ANY SITE WORK. CONTROLS SHOULD BE INSPECTED WEEKLY AND AFTER EACH RAINFALL. EXCAVATED MATERIAL SHOULD NOT BE DISPOSED OF IN THE WETLAND AREA. PROVIDE ADDITIONAL E&S MEASURES AS REQUIRED TO CONTROL EROSION AND SILTATION THROUGHOUT THE DURATION OF THE CONSTRUCTION AS CONDITIONS DICTATE AND/OR AS DIRECTED BY THE OWNER OR THE ENGINEER.
3. MONITOR AND INSPECT ALL E&S MEASURES IN AN ONGOING MANNER THROUGHOUT THE WORK AND TAKE CORRECTIVE MEASURES, AS REQUIRED, TO MINIMIZE EROSION OF SOILS AND PREVENT THE TRANSPORT OF SEDIMENTS AND OTHER
POLLUTANTS TO ANY RESOURCE AREAS.
4. ANY EROSION AND SEDIMENTATION MEASURE IMPLEMENTED BEYOND THAT SHOWN HEREON SHALL CONFORM TO APPLICABLE SECTIONS OF THE STATE OF CONNECTICUT'S 2024 “CONNECTICUT GUIDELINES FOR SOIL EROSION AND SEDIMENT
CONTROL."
5. ANY STOCKPILED MATERIAL SHALL BE SUBJECT TO EROSION CONTROL MEASURES THAT INCLUDE A MINIMUM OF SILT FENCE OR HAY BALE BARRIER. COVER STOCKPILES IF SIGNIFICANT RAINFALL IS PREDICTED.
6. PROVIDE TEMPORARY SEEDING WITH MULCH ON ALL EXPOSED SOIL AREAS WHERE WORK WILL BE SUSPENDED FOR LONGER THAN 30 DAYS. APPLY SEED AND MULCH WITHIN THE FIRST 7 DAYS OF SUSPENDING WORK. WHEN SEEDING IS NOT POSSIBLE DUE TO SEASONAL WEATHER CONDITIONS OR OTHER FACTORS, PROVIDE TEMPORARY STRUCTURAL SOIL PROTECTION SUCH AS MULCH, WOODCHIPS, EROSION CONTROL MATTING, OR COMPOST.
7. ALL TEMPORARY SLOPES IN EXCESS OF 3 (HORIZONTAL) TO 1 (VERTICAL) SHALL BE STABILIZED WITH EROSION CONTROL MATTING OR APPROVED EQUIVALENT.
8. NO RUNOFF SHALL BE ALLOWED TO ENTER ANY STORMWATER SYSTEM OR EXIT THE SITE PRIOR TO TREATMENT FOR SEDIMENT REMOVAL.
9. THE CONTRACTOR SHALL MAINTAIN A CLEAN CONSTRUCTION SITE AND SHALL NOT ALLOW THE ACCUMULATION OF RUBBISH OR CONSTRUCTION DEBRIS. ALL TRASH SHALL BE CLEANED ON A DAILY BASIS AND THE SITE SHALL BE LEFT IN A NEAT
CONDITION AT THE END OF EACH WORK DAY.
10. TAKE ALL NECESSARY PRECAUTIONS TO AVOID THE SPILLAGE OF FUEL OR OTHER POLLUTANTS AND ADHERE TO ALL APPLICABLE POLICIES AND REGULATIONS RELATED TO SPILL PREVENTION, CONTROL, AND RESPONSE.
11. FOR DUST CONTROL, PERIODICALLY MOISTEN EXPOSED SOIL SURFACES WITH WATER AND MAINTAIN ADEQUATE MOISTURE LEVELS.
12. SWEEP ADJACENT ROADWAYS IF MUD OR SOIL IS TRACKED ON TO THEM, OR AS DIRECTED BY THE ENGINEER.
13. ALL SEDIMENTATION AND EROSION CONTROL MEASURES SHALL BE INSTALLED BY THE PERMITTEE AND INSPECTED BY THE TOWN ENGINEER AND/OR THE WETLANDS ENFORCEMENT OFFICER / DULY AUTHORIZED AGENT; ADDITIONAL OR SUPPLEMENTAL CONTROLS MAY BE REQUIRED. THE PERMITTEE SHALL MAINTAIN THE CONTROLS DURING AND AFTER CONSTRUCTION AND REMOVE THEM UPON SITE STABILIZATION OF THE AFFECTED AREA.
14. AN ANTI-TRACKING APRON SHALL BE INSTALLED AT THE SITE ACCESS DRIVE AT A LOCATION APPROVED BY THE TOWN ENGINEER, WITH 6 INCHED OF CRUSHED STONE (SIZED 1 12" TO 3") UNDERLAIN WITH CONSTRUCTION FRAME SPREAD TO THE TRAVELED WIDTH AND 40 FEET IN LENGTH OR WITH APRON MATS. THE APRON SHALL BE MAINTAINED AT ALL TIMES.
15. THE PERMITTEE AND THEIR CONTRACTOR SHALL MEET WITH AGENCY STAFF, INCLUDING BUT NOT LIMITED TO THE WETLANDS ENFORCEMENT OFFICER / DULY AUTHORIZED AGENT AND TOWN ENGINEER, TO REVIEW THE CONDITIONS OF THIS APPROVAL AND THE CONSTRUCTION PROGRAM TO BE UTILIZED TO IMPLEMENT THE APPROVED REGULATED ACTIVITY.
16. THE WETLANDS ENFORCEMENT OFFICER / DULY AUTHORIZED AGENT SHALL BE NOTIFIED IN WRITING FORTY-EIGHT (48) HOURS PRIOR TO THE START OF CONSTRUCTION.
17. DURING THE DURATION OF THIS APPROVAL, THE CHAIRMAN OF THE AGENCY OR THE WETLANDS ENFORCEMENT OFFICER / DULY AUTHORIZED AGENT SHALL HAVE PERMISSION TO ENTER UPON THE SUBJECT PROPERTY AT REASONABLE TIMES FOR THE PURPOSE OF VIEWING AND INSPECTING THE CONDUCT OF THE APPROVED REGULATED ACTIVITY.
18. NO WORK OTHER THAN MAINTENANCE OF SEDIMENT AND EROSION CONTROL SHALL BE PERFORMED DURING SIGNIFICANT RAINFALL OF ONE (1) INCH OR MORE WITHIN A TWENTY-FOUR (24) HOUR PERIOD. ALL WORK SHALL BE PERFORMED BETWEEN 8:00 AM AND 5:00 PM, MONDAY THROUGH FRIDAY. NO WORK MAY BE CONDUCTED ON LEGAL HOLIDAYS OR WEEKENDS WITHOUT THE EXPRESSED APPROVAL OF THE AGENCY.
19. UPON COMPLETION OF THE REGULATED ACTIVITY APPROVED HEREIN, THE PERMITTEE SHALL NOTIFY THE WETLANDS ENFORCEMENT OFFICER / DULY AUTHORIZED AGENT FOR A FINAL INSPECTION AND CONFIRMATION OF SATISFACTORY COMPLETION AND COMPLIANCE WITH THE APPROVED SITE PLANS AND ALL STANDARD AND SPECIAL SUPPLEMENTAL CONDITIONS, REQUIREMENTS AND MODIFICATIONS OF THIS APPROVAL.
FILTER INSERTS IN
DRAINAGE SYSTEM
WEEKLY & WITHIN 24 HOURS
AFTER STORM GENERATING A
DISCHARGE
MAINTENANCE MEASURES SCHEDULEE&S MEASURE
TEMPORARY E&S MEASURES MAINTENANCE SCHEDULE
HAY BALES/ SILT
FENCE BARRIER
WEEKLY & WITHIN 24 HOURS
AFTER STORM GENERATING A
DISCHARGE
CONSTRUCTION
ENTRANCE
WEEKLY
MOISTEN
EXPOSED SOILS
DAILY
CLEAN CATCH BASIN GRATE, REMOVE
SEDIMENT/DEBRIS FROM FILTER INSERTS
REPAIR/REPLACE WHEN FAILURE OBSERVED,
REMOVE SILT WHEN ACCUMULATION REACHES
APPROX. HALF HEIGHT OF BARRIER
SWEEP PAVED ROADWAY ADJACENT TO SITE
ENTRANCE AS NECESSARY, REFRESH STONE AS
NECESSARY, REMOVE SILTED GRAVEL
PERIODICALLY MOISTEN EXPOSED SOIL
SURFACES WITH WATER ON UNPAVED
TRAVELWAYS AND KEEP TRAVELWAYS DAMP
SUGGESTED CONSTRUCTION SEQUENCE:
1. CONDUCT A PRE-CONSTRUCTION MEETING WITH THE OWNER AND ENGINEER PRIOR TO ANY
CONSTRUCTION ACTIVITY.
2. INSTALL PERIMETER E&S CONTROLS AND REQUEST PRE-CONSTRUCTION INSPECTION FROM THE
ENGINEER.
3. REMOVE EXISTING PAVEMENT.
4. PERFORM BULK EARTHWORK OPERATIONS.
5. BEGIN CONSTRUCTION OF BUILDING ADDITION FOUNDATION.
6. CONSTRUCT CURBING, WALKS, AND TOP COURSE OF BITUMINOUS PAVEMENT.
7. AT THE CONCLUSION OF CONSTRUCTION, COMPLETE THE INSTALLATION OF
POST-CONSTRUCTION SITE STABILIZATION MEASURES AS SHOWN ON THE DRAWINGS.
8. ONCE SITE IS FULLY STABILIZED REMOVE ALL EROSION CONTROLS.
SHEET NO.
PROFESSIONAL SEAL
21 Talcott Notch Road Farmington, CT 06032 friar.com 860.678.1291
CONSULTANT
DATE:
SCALE
PROJ. #:
DRAWN:
CHECKED:
Alfred Benesch & Company 200 Glastonbury Blvd., Suite 201 Glastonbury, Connecticut 06033 860-633-8341
DRIGGS
ELEMENTARY
SCHOOL ELEVATOR
ADDITION
STATE PROJECT NUMBER
77 Woodlawn Terrace Waterbury, CT 06710
2022_049A
01/15/2026
151-0315 LUE
REVISIONS
NO. DATE DESCRIPTION
SHEET NO.
PROFESSIONAL SEAL
21 Talcott Notch Road Farmington, CT 06032 friar.com 860.678.1291
CONSULTANT
DATE:
SCALE
PROJ. #:
DRAWN:
CHECKED:
Alfred Benesch & Company 200 Glastonbury Blvd., Suite 201 Glastonbury, Connecticut 06033 860-633-8341
DRIGGS
ELEMENTARY
SCHOOL ELEVATOR
ADDITION
STATE PROJECT NUMBER
77 Woodlawn Terrace Waterbury, CT 06710
2022_049A
01/15/2026
151-0315 LUE
REVISIONS
NO. DATE DESCRIPTION
TEMPORARY STOCKPILE LOCATION
SILT FENCE (TYP.)
CONSTRUCTION FENCE (TYP.)
EXISTING STAIRCASE TO BE REMOVED
EXISTING PORTION OF BUILDING TO BE REMOVED
(REFER TO ARCHITECTURAL DRAWINGS)
SILT FENCE BARRIER (SF)
N.T.S.
2'-6"
1'-6"
SECTIONELEVATION
*NOTE: POST SPACING AND EMBEDMENT VARIES
BASED ON THE FABRIC MANUFACTURER'S
REQUIREMENTS.
EXTRA STRENGTH SEDIMENT CONTROL FABRIC (AMOCO
PROPEX OR EQUAL)
10' MAX.*
100°
BURY FABRIC 6" BELOW
GROUND
GRADE
WOOD POST
SLOPE
6'
SILT FENCE
SURROUNDING
STOCKPILE 3:1 SLOPE MAX
TEMPORARY VEGETATIVE COVER TO BE
ESTABLISHED ON TOPSOIL STOCKPILE PER CT
DEEP E&S GUIDELINES
NOTE:
STOCKPILE IS NOT TO BE PLACED
ADJACENT TO SLOPES GREATER
THAN 3:1
TEMPORARY STOCKPILE (STK)
N.T.S.
HAY BALE BARRIER (HB)
N.T.S.
PROTECTED
WORK AREA
FLOW
TOP OF GROUND
18" (MIN.)
AREA
HAY BALES
BINDINGS TO BE PARALLEL
TO GROUND SURFACE
EMBED HAY BALES 4" INTO
GROUND. BACKFILL AND
COMPACT EXCAVATED FILL
ALONG HAY BALES
2"x11
2"x36" WOOD STAKE OR
STEEL POSTS WITH A MIN.
OF 0.5 POUNDS PER LINEAR
FOOT (2 PER HAY BALE)
NOTES:
1. HAY BALES SHALL BE MADE OF HAY OR STRAW WITH 40 POUND MIN. WEIGHT AND 120
POUND MAX. WEIGHT HELD TOGETHER BY TWINE OR WIRE.
2. PLACE HAY BALES ON CONTOUR AND WING THE LAST HAY BALES UP SLOPE SO THAT THE
TOP OF THE LAST SEVERAL HAY BALES ARE HIGHER THAN THE LINE OF HAY BALES.
3. DRIVE FIRST STAKE IN EACH BALE TOWARD THE PREVIOUSLY LAID BALE TO FORCE THEM
TOGETHER.
4. PUT ONE HAY BALE PERPENDICULAR ALONG HAY BALE BARRIER EACH 100 FEET.
STAKED HAY BALES
CROSS-SECTION
PLAN VIEW
FIELD VARIABLE
FI
EL
D V
AR
IA
BL
E
10' (MIN.)
OVERLAP
1'
NOTES:
1. CONSTRUCT WASHOUT AREA LARGE ENOUGH TO ENSURE MATERIALS WILL BE CONTAINED
WHERE WASTE CONCRETE CAN SOLIDIFY IN PLACE AND EXCESS WATER CAN SAFELY
EVAPORATE.
2. WASHOUT AREA SHALL BE LARGE ENOUGH TO RETAIN ALL LIQUID AND WASTE CONCRETE
MATERIALS FROM WASHOUT OPERATION.
3. WEEKLY INSPECTIONS OF WASHOUT AREAS SHALL BE CONDUCTED TO ASSESS THE
HOLDING CAPACITY AND FUNCTIONALITY OF THE WASHOUT AREA.
30-MIL PVC IMPERVIOUS
LINER
SEAL LINER; SEALANT NOT TO
PIERCE LINER
30-MIL PVC IMPERVIOUS
LINER
2"x11
2"x36" WOOD STAKE OR
STEEL POSTS WITH A MIN.
OF 0.5 POUNDS PER LINEAR
FOOT (2 PER HAY BALE)
30-MIL IMPERVIOUS LINER
BURY LINER 4"
TEMPORARY CONCRETE WASHOUT AREA (CWA)
N.T.S.
OR DRIVEN
POST
SCRIM SHEETING
CONSTRUCTION FENCE
N.T.S.
CONCRETE WASHOUT AREA
EXISTING BITUMINOUS WALK TO BE REMOVED (TYP.)
PROTECT EXISTING RETAINING WALL
(WHERE NOT SPECIFICALLY CALLED
FOR DEMO)
REMOVE EXISTING FENCE FOR SITE ACCESS
(EXISTING FENCE TO BE REINSTALLED)
TAKE GREAT CARE TO NOT DAMAGE EXISTING UTILITY
DEMOLITION & SITE
C1.0GSL
WGW
PREPARATION PLAN
1" = 10'
HAYBALES (TYP.)
PROTECT EXISTING
COMMUNICATIONS SERVICE (TYP.)
6'
SILT FENCE
SURROUNDING
STOCKPILE 3:1 SLOPE MAX
TEMPORARY VEGETATIVE COVER TO BE
ESTABLISHED ON TOPSOIL STOCKPILE PER CT
DEEP E&S GUIDELINES
NOTE:
STOCKPILE IS NOT TO BE PLACED
ADJACENT TO SLOPES GREATER
THAN 3:1
TEMPORARY STOCKPILE (STK)
N.T.S.
EROSION AND SEDIMENTATION CONTROL NARRATIVE:
PER STATE OF CONNECTICUT
ALL APPLICABLE PRACTICES RECOMMENDED BY THE 2024 CONNECTICUT GUIDELINES FOR SOIL EROSION AND SEDIMENT CONTROL AS AMENDED.
DESCRIPTION
THE PROJECT CONSISTS OF PROVIDING ADA ACCESSIBILITY TO THE BUILDING IN THE NORTHERN PARKING LOT AND CONSTRUCTING AN ELEVATOR
ADDITION ON THE SOUTHERN BUILDING WALL WITH A CONCRETE WALK FOR ACCESS.
DESIGN AND CRITERIA
NOTE: THE CONTRACTOR SHALL NAME ONE INDIVIDUAL AS HIS SEDIMENT AND EROSION CONTROL SUPERVISOR WHOSE PRIMARY RESPONSIBILITY WILL BE THE MAINTENANCE OF ALL ON-SITE EROSION CONTROL MEASURES. HE WILL KEEP A DAILY LOG OF HIS ACTIVITIES AND AN UPDATED SCHEDULE OF PROPOSED CONSTRUCTION ACTIVITIES. THE LOG WILL BE MADE AVAILABLE TO INSPECTORS.
A. GEOTEXTILE SILT FENCE (SF) - SHALL BE NON-WOVEN MATERIAL, MINIMUM 36" HIGH AND FASTENED TO WOOD STAKES. SILT FENCE SHALL BE INSTALLED WITH END RUNS TURNED UP GRADE AT 45 DEGREES FOR A DISTANCE OF 10 FEET (SEE DETAIL THIS SHEET).
B. TEMPORARY SEEDING (TS)
1. CONTRACTOR SHALL SCARIFY THE SOIL TO A DEPTH OF 2" BEFORE APPLYING FERTILIZER, LIMESTONE AND SEED.
2. SEED MAY BE APPLIED BY HAND OR MECHANICALLY. SEED APPLICATION SHALL BE UNIFORM. SEED RATE SHALL BE IN ACCORDANCE WITH THE 2002 CONNECTICUT GUIDELINES FOR SOIL EROSION AND SEDIMENT CONTROL AS AMENDED (INCREASE SEEDING RATES BY
10% WHEN HYDROSEEDING, LIMESTONE, FERTILIZER AND SEED MAY BE APPLIED IN SLURRY.)
3. CONTRACTOR SHALL MULCH AREA (MS) IMMEDIATELY FOLLOWING SEEDING. (NOTE: IN THE EVENT SEEDING OPERATIONS ARE NOT FEASIBLE DUE TO SEASONAL RESTRICTIONS OR EXTENDED INCLEMENT WEATHER PATTERNS, THE CONTRACTOR SHALL INSTALL AN
EROSION CONTROL BLANKET OVER EXPOSED SOILS.)
C. PERMANENT SEEDING (PS)
1. CONTRACTOR SHALL APPLY TOPSOIL AND FINE GRADE ALL AREAS BEFORE THE APPLICATION OF PERMANENT SEED. APPLY LIMESTONE
AND FERTILIZER AS NEEDED, IN ACCORDANCE WITH SOIL TESTS.
2. REMOVE ALL SURFACE STONES ½ INCH AND LARGER. REMOVE ALL OTHER DEBRIS AND RAKE SEED BED.
3. APPLY SEED WITHIN 7 DAYS AFTER ESTABLISHING FINAL GRADES. SEE PLANTING PLAN.
D. STRAW BALE BARRIER (HB) - SHALL BE MADE OF STRAW WITH 40 POUNDS MINIMUM WEIGHT AND 120 POUNDS MAXIMUM WEIGHT, HELD
TOGETHER BY TWINE OR WIRE. (SEE DETAIL THIS SHEET.)
E. CONSTRUCTION ENTRANCE (CE) - SHALL BE AN ANGULAR STONE PAD, A MINIMUM OF 12' WIDE AND 50' LONG. (SEE DETAIL THIS SHEET.)
F. EROSION CONTROL BLANKET (ECB) - EROSION MAT SHALL BE PLACED ON ALL EXPOSED CUT/FILL SLOPES STEEPER THAN 3:1 (INCLUDING SWALES & DITCHES) TO PROTECT AGAINST RAINFALL AND HOLD MOISTURE CONTENT TO ENHANCE VEGETATION GROWTH IN SEEDED AREAS. MAT (OR BLANKETS) SHALL BE STRAW OR STRAW/COCONUT FIBER COMBINATION SEWN TOGETHER WITH LIGHTWEIGHT NETTING. USE NORTH AMERICAN GREEN. S150 - SLOPES UP TO 3:1, SC150-SLOPES FROM 3:1 UP TO 2:1 OR GREATER. TEMPORARY HAY MULCH TO BE APPLIED TO AREAS LESS THAN 3:1 SLOPE AND ALL AREAS TO BE LEFT BARREN OVER THE WINTER, MULCH RATE TO BE 70 POUNDS/1000 S.F.
APPLICATION/GENERAL PROCEDURES
SOIL EROSION AND SEDIMENT CONTROL MEASURES WILL BE INSTALLED PRIOR TO ANY SITE DISTURBANCE, AND DEVELOPMENT WILL PROCEED ACCORDING TO A SPECIFIC CONSTRUCTION SEQUENCE. THE OBJECTIVE IS TO MAXIMIZE THE REDUCTION OF SEDIMENT-LADEN RUNOFF THROUGH IMPLEMENTATION OF CONVENTIONAL SOIL SEDIMENTATION AND EROSION CONTROL PRACTICES CURRENTLY RECOMMENDED BY THE 2024
CONNECTICUT GUIDELINES FOR SOIL EROSION AND SEDIMENT CONTROL
A. EARTHWORK WILL BE SCHEDULED FOR PERIODS WHEN SOIL SATURATION IS LOW AND SOIL LOSS HAZARD IS AT A MINIMUM.
B. SUSPEND EARTHWORK FOR MAJOR STORM EVENTS AND IMPLEMENT ADDITIONAL SEDIMENTATION AND EROSION CONTROL MEASURES AS
NECESSARY.
C. THERE SHALL BE NO CUTS OR FILL LEFT EXPOSED FOR LONGER THAN 30 DAYS. THE ESTABLISHED PROCEDURE OF TEMPORARILY SEEDING AND/OR COVER WITH EROSION PROTECTION (MAT OR STRAW) SHALL BE FOLLOWED TO INSURE MINIMAL SOIL LOSS.
D. THE DISCHARGE OF UNTREATED STORMWATER TO ANY ADJACENT ROADWAYS, DRAINAGE INLETS, OR PROPERTIES IS NOT ALLOWED.
SITE PREPARATION NOTES:
1. CONTRACTOR SHALL NOTIFY “CALL BEFORE YOU DIG” (1-800-922-4455) AND VERIFY UTILITY MARK-OUT WITH THE
OWNER PRIOR TO THE INITIATION OF ANY SITE DISTURBANCE.
2. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR VERIFICATION OF THE LOCATION AND NATURE OF ALL SUBSURFACE UTILITIES AT THE PROJECT WHICH MAY BE AFFECTED BY THE WORK. COORDINATE WITH RESPECTIVE UTILITY
OWNERS AND PERFORM VERIFICATION OF TYPE, LOCATION, AND INVERTS AS REQUIRED.
3. PROTECT ALL IMPROVEMENTS NOT INCLUDED WITHIN THE LIMITS OF WORK. ANY IMPROVEMENT WHICH IS DAMAGED
SHALL BE REPAIRED OR REPLACED IN-KIND TO THE OWNER'S SATISFACTION.
4. DURING DEMOLITION, PROTECT ALL ADJACENT CURBING, SIDEWALKS, RAMPS, ABOVE-GRADE AND BELOW-GRADE UTILITIES, DRAINAGE STRUCTURES, LIGHT BASES, AND OTHER IMPROVEMENTS POTENTIALLY AFFECTED BY THE WORK. CLEARLY DELINEATE THE LIMITS OF WORK AND MARK, BARRICADE, OR OTHERWISE IDENTIFY THOSE IMPROVEMENTS THAT ARE TO BE PROTECTED AND/OR AVOIDED. ANY IMPROVEMENT WHICH IS DAMAGED SHALL BE
REPAIRED OR REPLACED IN-KIND TO THE OWNER'S SATISFACTION.
5. THE LOCATIONS OF EXISTING SITE FEATURES AS SHOWN HAVE BEEN OBTAINED FROM MAPS, SURVEYS, FIELD INSPECTIONS, AND OTHER AVAILABLE INFORMATION. THEY MUST BE CONSIDERED APPROXIMATE BOTH TO LOCATION, SIZE, AND AS-BUILT CONDITION AND ARE PROVIDED FOR INFORMATIONAL PURPOSES ONLY. THE
CONTRACTOR IS SOLELY RESPONSIBLE FOR DETERMINING ACTUAL FIELD CONDITIONS.
6. THE DIMENSIONS SHOWN ON THE PLANS, INCLUDING THE INTENDED DIMENSIONS OF THE WORK, MAY VARY FROM ACTUAL EXISTING CONDITIONS IN THE FIELD. THE CONTRACTOR SHALL TAKE APPROPRIATE MEASUREMENTS TO VERIFY ALL DIMENSIONS SHOWN ON THE DRAWINGS AS WELL AS OTHER DIMENSIONS HE MAY DEEM APPROPRIATE TO FACILITATE THE COMPLETION OF THE WORK. NOTIFY THE ENGINEER OF ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS BEFORE PROCEEDING WITH THAT PORTION OF THE WORK.
7. IMPLEMENTING WORKER SAFETY AND/OR HEALTH PROTOCOLS THAT ADDRESS COMPLIANCE WITH RULES, LAWS, AND REGULATIONS PERTAINING TO CONSTRUCTION SAFETY AND/OR THE POTENTIAL AND/OR ACTUAL RISK OF EXPOSURE TO SITE-SPECIFIC PHYSICAL OR CHEMICAL HAZARDS IS SOLELY THE RESPONSIBILITY OF THE CONTRACTOR.
8. PRIOR TO THE TERMINATION, ABANDONMENT, OR REMOVAL OF ANY UTILITY, VERIFY THAT APPLICABLE NOTIFICATIONS HAVE BEEN MADE TO THE UTILITY OWNER/OPERATOR AND THAT THE UTILITY HAS BEEN PROPERLY
TERMINATED, CAPPED, OR PLUGGED AS REQUIRED.
9. PROVIDE PAVEMENT SAWCUT AT THE EDGE OF EACH PAVEMENT REMOVAL AREA TO ESTABLISH A CLEAN EDGE WHERE NEW WORK WILL MEET EXISTING PAVEMENT. SAWCUT SHALL BE A MINIMUM OF 12 INCHES FROM EDGE OF
PAVEMENT REMOVAL.
10. UNLESS OTHERWISE INDICATED, ALL DISTURBED AREAS SHALL BE RESTORED WITH SIX (6) INCHES OF LOAM, SEEDED, FERTILIZED, AND MULCHED. PROVIDE ADDITIONAL EROSION CONTROLS AS REQUIRED.
11. ALL SIDEWALK CLOSURES AND MEASURES FOR TEMPORARY PEDESTRIAN ACCESS, SIDEWALKS, CROSSINGS, AND
BIKE LANES SHALL MEET THE APPROVAL OF THE CITY OF WATERBURY.
PORTION OF EXISTING FENCE AND WALL TO
BE REMOVED (COORDINATE WITH SITE PLAN)
xxxxxxxxxx x x x x x x x
IRVING STREET
GFE: 462.26
SFE: 474.25
SG: 461.96
SG: 461.90
SG: 461.79
SG: 461.70
SG: 461.97
SG: 462.05
SG: 461.49
TW: 464.10
BW: 462.00
SG: 462.15
SG: 462.23
GFE: 462.26
SG: 462.15
SG: 462.13
TW: 464.50
BW: 462.13
SG: 462.26
SG: 462.26
TW: 464.72
BW: 462.24
TW: 464.40
BW: 462.00
TW: 465.00
BW: 462.26
EX: 461.20
EX: 461.12
SG: 462.26
TW: 464.60
BW: 462.05
TW: 464.60
BW: 462.10
SG: 462.02
SCALE: NONE
COMPACTED SUBGRADE
REINFORCED CAST-IN-PLACE CONCRETE
W/ WWF (4 X 4 W2.9 X W2.9) IN FLAT
SHEETS CONTINUOUS THROUGH SCORE
JOINTS
DOWELED EXPANSION JOINT -'EJ' (TYP.)
W/ PREMOLDED JOINT FILLER AND
TOOLED EDGES
CONTROL JOINT W/ TOOLED EDGES W/ 1/4"
WIDE x 1" DEEP (TYP.)
FINISH GRADE
BROOM FINISH PERPENDICULAR TO
DIRECTION OF TRAVEL
NOTES:
1. PROVIDE 1/2" EXPANSION JOINTS WITH PERFORMED JOINT
FILLER AT 20'-0" O.C. MAX. OR AS INDICATED ON PLAN.
2. PROVIDE 1" DEEP TROWELED CONTROL JOINTS AT 5'-0" O.C.
OR AS INDICATED ON PLAN.
JOINT SEALER
2'-0" X 58" DIA. SMOOTH STEEL DOWEL
(2'-0" O.C.) WITH ONE END GREASED
FILTER FABRIC
COMPACTED SUBBASE
LIGHT DUTY CONCRETE SIDEWALK
SCALE: NONE
SEE SITE PLAN
SE
E
SI
TE
P
LA
N
4' CHAIN LINK FENCE & GATE
1 5/8" TOP RAIL
DOME CAP
1 5/8" BRACE RAIL
AT CORNERS
TENSION BANDS 1'
O.C.
2 7/8" CORNER POST
4" MINIMUM
TERMINAL POST
STRETCHER BAR
1/4" X 3/4"
3/8" TRUSS W/TURNBUCKLES
(CORNERS)
CONC. FOOTING
9 GA. 2" FABRIC
2 3/8" LINE POST
3" BOX HINGES
1 5/8" BOTTOM RAIL
OR 7 GA. TENSION
WIRE
INSTALL 3" BELOW TOP OF GATE
CONC. FOOTING
l l xxxxxxxxxxxxxxxxxx x x x x x x x x x x x x
IRVING STREET
REMOVE AND RESET EXISTING 4' BLACK VINYL COATED CHAIN LINK FENCE AND GATE
ELEVATOR ADDITION
FFE: 462.26
BUILDING MOUNTED ADA PARKING SIGN
ADA PARKING STALL
(2% MAX SLOPE IN ALL DIRECTIONS)
NEW BITUMINOUS PAVEMENT (TYP.)
MAINTAIN EXISTING CONCRETE
PAD AT DOORWAY
EXISTING CONCRETE WALK IN ROW TO REMAIN
DAYLIGHT DOWNSPOUT TO GRADE
INV: (464.80±)
PROVIDE CONCRETE SPLASH PAD
EXISTING COMMS SERVICE TO BE PROTECTED
TAKE GREAT CARE TO PROTECT EXISTING
UNDERGROUND UTILITY DURING DEMOLITION
OF EXISTING WALK AND FIRE ESCAPE
FOOTING DRAIN PUMP (SEE NOTES)
TF: 466.10 (M.F.G.)
INV: 464.50 (OUT)
14.5' - 6" HDPE @ 3.45%
DAYLIGHT PIPE WITH VERMIN SCREEN
INV: 464.00
4' BLACK VINYL COATED CHAIN LINK FENCE (MATCH EXISTING)CONNECT EXISTING FENCE TO NEW 4' BLACK
VINYL CHAIN LINK FENCE ON TOP OF MODULAR
CONCRETE BLOCK WALL
MODULAR CONCRETE BLOCK WALL
PROPOSED LAWN AREA / LAWN RESTORATION (TYP.)
ENSURE SUFFICIENT PITCH IS MAINTAINED
TO DRAIN TOWARD IRVING STREET
EXPANSION JOINT (TYP.)
CONSTRUCTION JOINT (TYP.)
WASHED RIVER STONE GRAVEL BED (TYP.)
Va rie s
6"
Pi pe
1'
6"
PIPE O.D. PLUS
24" OR 3'-0" MIN.
GRAVEL FILL AS DIRECTED BY
ENGINEER WHEN UNSUITABLE
MATERIAL IS ENCOUNTERED
3/8" TO 3/4" CRUSHED STONE PLACED AND
COMPACTED IN 6" LAYERS. CRUSHED STONE
IN WET INSTALLATIONS
COMPLETE ENVELOPE OF FILTER FABRIC WITH
12" OVERLAP REQUIRED WHEN CRUSHED
STONE IS USED AS BEDDING MATERIAL,
FILTER FABRIC REQUIRED IN ROCK
CUT AS DIRECTED BY ENGINEER
GRAVEL BACKFILL PLACED AND COMPACTED
IN 12" LAYERS (UNDER PVMNTS.)
EXCAVATED MATERIAL (UNDER PLANTING)
WARNING
TAPE
VA
RI
ES
SEE LANDSCAPE SECTION
SEE
HARDSCAPE
SECTION
OR
1'- 6"
M
IN
EXISTING DOOR
5" THICK 4,000 PSI CONCRETE PAD
NO. 4 HORZ. BAR, 16" O.C.
NO. 4 BAR, TOP AND BOTTOM
NO. 4 BAR, 16" O.C., BOTH WAYS
EXISTING BUILDING
FOUNDATION, CONNECT
TO FROST PAD WITH
DOWEL
5'-0"
GRANULAR FILL
NO. 4 HORZ. BAR, 16" O.C.
8"8"
8"
" M
IN
NO. 5 STAINLESS 12"
DOWELS 12" O.C. MAX
SEE CONCRETE WALK DETAIL
SCALE: NONE
FROST PAD
ACCESSIBILITY NOTES:
1. SLOPES ALONG THE ACCESSIBLE ROUTE SHALL BE LESS THAN 1:20 (5%) AND THE
CROSS SLOPES SHALL NOT EXCEED 1:50 (2%). CHANGES IN LEVELS SHALL NOT BE
GREATER THAN 14 INCH.
2. LANDINGS SHALL NOT HAVE A SLOPE GREATER THAN 1:50 (2%) IN ANY DIRECTION.
3. SLOPES WITHIN THE ACCESSIBLE PARKING SPACE SHALL NOT EXCEED 1:50 (2%) IN
ANY DIRECTION.
LAYOUT NOTES:
1. NEW PAVEMENT TO MEET LINE & GRADE OF EXISTING PAVEMENTS.
2. ALL LINES AND DIMENSIONS ARE PARALLEL OR PERPENDICULAR TO THE LINES
FROM WHICH THEY ARE MEASURED.
3. FIELD ADJUSTMENTS MUST BE APPROVED BY THE OWNER'S REPRESENTATIVE AND
APPROPRIATE MUNICIPAL OFFICIALS PRIOR TO CONSTRUCTION.
4. CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE VERTICAL AND HORIZONTAL
POSITION OF EXISTING UTILITIES PRIOR TO CONSTRUCTION.
5. A DIGITAL CAD FILE CAN BE PROVIDED TO THE CONTRACTOR FOR THE LAYOUT OF
SITE IMPROVEMENTS IN THE FIELD.
MATERIALS NOTES:
1. MATERIALS AND CONSTRUCTION PROCEDURES SHALL COMPLY WITH CT DOT FORM
819, THE CITY OF WATERBURY REGULATIONS AND THE PROJECT MANUAL.
2. ALL LOCATIONS WHERE EXISTING CURBING, BITUMINOUS CONCRETE ROADWAY OR
CONCRETE ROADWAY OR CONCRETE SIDEWALK ABUT NEW CONSTRUCTION, THE
EDGE OF THE EXISTING CURB OR PAVEMENT SHALL BE SAW CUT TO PROVIDE A
CLEAN, SMOOTH EDGE. TACK COAT EXPOSED EDGES OF EXISTING CONCRETE
PRIOR TO PLACEMENT OF NEW BITUMINOUS CONCRETE PAVEMENT.
3. MANUFACTURED ITEMS SHALL BE INSTALLED, CONNECTED AND CLEANED
ACCORDING TO THE MANUFACTURERS DIRECTIONS.
4. EXPANSION AND SCORE JOINTS FOR NEW CONCRETE WALKS SHALL BLEND TO
MATCH EXISTING PATTERNS. CONTRACTOR TO ARRANGE TIMELY ON-SITE
CONFERENCES WITH LANDSCAPE ARCHITECT TO APPROVE LAYOUT OF JOINT
PATTERNS.
5. PROVIDE EXPANSION JOINTS FOR NEW CONCRETE PAVING AT ALL CURBS, TREE
GRATES, BUILDING WALLS, SITE WALLS, STAIRS, LIGHT POLE BASES, MANHOLES,
GRATES/VAULTS, EXISTING CONCRETE PAVING, STOP LIGHTS, FIRE HYDRANTS AND
ALL OTHER FIXED MATERIALS. MAXIMUM DISTANCE BETWEEN EXPANSION JOINTS
SHALL NOT EXCEED 20 FEET.
SHEET NO.
PROFESSIONAL SEAL
21 Talcott Notch Road Farmington, CT 06032 friar.com 860.678.1291
CONSULTANT
DATE:
SCALE
PROJ. #:
DRAWN:
CHECKED:
Alfred Benesch & Company 200 Glastonbury Blvd., Suite 201 Glastonbury, Connecticut 06033 860-633-8341
DRIGGS
ELEMENTARY
SCHOOL ELEVATOR
ADDITION
STATE PROJECT NUMBER
77 Woodlawn Terrace Waterbury, CT 06710
2022_049A
01/15/2026
151-0315 LUE
REVISIONS
NO. DATE DESCRIPTION
00 10' 20'
SCALE: 1" = 10'
LAWN
SCALE: NONE
DETAILED GRADING PLAN
SCALE: NONE
SITE PLAN
SCALE: NONE
3" BITUMINOUS CONCRETE
SURFACE COURSE 2 EQ. LIFTS
WIDTH VARIES
2% (MAX.)
SLOPED TOWARD GUTTER
2" 11
2"
8" GRAVEL BASE
COMPACTED IN 4" LIFTS
3"
BITUMINOUS DRIVE AND SIDEWALK
SCALE: NONE
EXISTING GRADE
ALUMINUM PANEL STATE OF
CONNECTICUT APPROVED
ACCESSIBLE PARKING SIGN
(12" X 18")
80"
EXISTING BUILDING
3'-0" (TYP)
5' 10'
M
IN
4" WIDE PAINTED
WHITE LINES (TYP.)
NOTES:
1. GRADING WITHIN HANDICAP SPACES SHALL BE LESS THAN 2.00%. IN ALL DIRECTIONS
2. SIGN LOCATION VARIES - SEE PLAN
CONNECTICUT ADA PARKING SIGN
MOUNTED TO EXISTING BUILDING
EXISTING BUILDING
45°
ACCESSIBLE PARKING STALL
SCALE: NONE
ACCESSIBLE PARKING SIGN
SCALE: NONE
00 10' 20'
SCALE: 1" = 10'
SITE PLAN
C2.0GSL
WGW
1" = 10'
STORM TRENCH
SCALE: NONE
PUMP STATION NOTES:
PUMP STATION TO BE DEFERRED DESIGN SUBMITTED FOR ENGINEER REVIEW AS A
SHOP DRAWING. PUMP STATION TO BE DESIGNED BY UNITED CONCRETE PRODUCTS
OR SIMILAR VENDOR. PACKAGE SHALL INCLUDE: WET WELL, VALVES, FLOATS,
CONTROLS, REMOTE ACCESS, ETC.
DESIGN PARAMETERS:
· TDH: COORDINATE WITH MEP PLANS
· WET WELL SHALL HOLD MINIMUM 200 GALLONS BELOW THE INLET INVERT
· FORCE MAIN WILL BE APPROXIMATELY 57' AND WILL BE SIZE AS APPROPRIATE
FOR THE PUMPS
· SYSTEM SHALL INCLUDE DUPLEX PUMPS ACCESSIBLE VIA A RAIL SYSTEM
· THE PUMP STATION SHALL HAVE A FRAME AND COVER THAT IS FLUSH WITH
FINISHED GRADE
SEE DETAILED GRADING PLAN FOR WALL HEIGHT
ADHERE CAP UNIT
TO TOP UNIT
CONCRETE ADHESIVE
MODULAR CONCRETE
FACING UNITS
BURY 1 BLOCK
PROVIDE SWALE AT TOE OF SLOPE
TOPSOIL
GRAVEL DRAINAGE FILL
GEOGRID, MIRAGRID 5T
FILTER FABRIC
6" PROCESSED AGGREGATE LEVELING PAD
NOTE:
CONTRACTOR SHALL SUBMIT A RETAINING WALL DESIGN BY A MANUFACTURER REPRESENTATIVE FOR REVIEW AND APPROVAL BY THE ENGINEER. THE SHOP DRAWING SHALL INCLUDE HORIZONTAL AND VERTICAL DIMENSION, AS WELL AS ALL OTHER ASSEMBLED APPURTENANCES AND NOTES NECESSARY TO CONSTRUCT THE RETAINING WALL.
MODULAR CONCRETE BLOCK RETAINING WALL
SCALE: NONE
(MIN. 1.5FT BEHIND RETAINING WALL)
COMPACTED STONE MULCH
(34" DIA. WASHED RIVER STONE)
GEOTEXTILE FABRIC
COMPACTED SUBGRADE
N.T.S.
WASHED RIVER STONE GRAVEL BED
SCALE: NONE
DEMOLITION LEGEND: KEYED INTO PLAN
REMOVE EXISTING WALL
REMOVE DOOR AND FRAME
REMOVE EXTERIOR MASONRY WALL CONSTRUCTION
REMOVE SINK AND ASSOCIATED PIPING BACK TO SOURCE. REFER TO GENERAL
DEMOLITION NOTE 4 FOR PLUMBING INFORMATION
REMOVE SHELVING. SUPPLIES TO BE REMOVED BY OWNER.
REMOVE EXISTING WINDOW SYSTEM IN ITS ENTIRETY AND ASSOCIATED HARDWARE.
REMOVE EXISTING DOOR, HARDWARE, FRAME AND TRANSOM WINDOW IN IT'S
ENTIRETY.
REMOVE EXISTING DOOR AND HARDWARE. MAINTAIN EXISTING FRAME AND PATCH
WHERE HARDWARE HAS BEEN REMOVED.
REMOVE EXISTING CEILING, GRID AND ASSOCIATED FIXTURES. REFER TO MEP
DRAWINGS FOR ADDITIONAL INFORMATION.
REMOVE EXISTING METAL FIRE ESCAPE AND ASSOCIATED HARDWARE. PATCH &
REPAIR MASONRY FACADE.
REMOVE EXISTING FLOORING, BASEBOARD AND ANY ASSOCIATED SUBSTRATE AND
PREPARE SLAB FOR NEW FLOORING.
EXISTING HARD CEILING TO REMAIN. REMOVE EXISTING CEILING FIXTURES.
1. ANY DEMOLITION WORK ASSOCIATED WITH NEW WORK THAT IS NOT SPECIFICALLY NOTED
ON THIS PLAN SHALL BE THE RESPONSIBILITY OF THE DEMOLITION CONTRACTOR.
2. DEMOLISHED MATERIAL SHALL BE CONSIDERED TO BE THE PROPERTY OF THE CONTRACTOR
AND SHALL BE COMPLETELY REMOVED FROM THE JOB SITE.
3. SHUT OFF, CAP AND OTHERWISE PROTECT EXISTING PUBLIC UTILITY LINES IN ACCORDANCE
WITH THE REQUIREMENTS OF THE PUBLIC AGENCY HAVING JURISDICTION.
4. COMPLETELY REMOVE ITEMS SCHEDULED TO BE SO DEMOLISHED AND REMOVE, LEAVING
SURFACES CLEAN, SOLID AND READY TO RECEIVE NEW MATERIALS AND SPECIFIED
ELSEWHERE.
5. USE MEANS NECESSARY TO PREVENT DUST FROM BECOMING A NUISANCE TO THE USER.
6. THIS DRAWING DOES NOT DEPICT THE FULL EXTENT OF DEMOLITION. ADDITIONAL ITEMS
SCHEDULED FOR DEMOLITION MAY BE FOUND ON OTHER DRAWINGS. CONSTRUCTION
MANAGER IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK WITH ALL PARTIES
INVOLVED.
7. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL NATIONAL, STATE, LOCAL
CODES & ORDINANCES.
8. ALL EXISTING (FREESTANDING) FURNITURE ITEMS IN ALL ROOMS UNDER SCOPE OF WORK TO
BE REMOVED BY OWNER.
9. DEMOLITION CONTRACTOR MUST VERIFY LOCATIONS OF ALL EXISTING STRUCTURAL,
MECHANICAL, PLUMBING & ELECTRICAL ELEMENTS PRIOR TO START OF DEMOLITION.
10. REMOVE ALL INTERIOR WALLS SHOWN DOTTED, ALONG WITH ALL ASSOCIATED TACK
BOARDS, CHALK BOARDS, MARKER BOARDS, ETC. EXERCISE CAUTION SO AS NOT TO DISTURB
OR DAMAGE ADJACENT SURFACES SCHEDULED TO REMAIN.
11. REMOVE ALL PLUMBING FIXTURES INCLUDING SINKS, WATER CLOSETS, URINALS, SLOP SINKS
AND DRINKING FOUNTAINS WITHIN DEMOLITION AREAS. REMOVE AND CAP ALL PLUMBING
LINES BEHIND FINISHED WALL AND FLOOR SURFACES. REFER TO PLUMBING DEMOLITION
DRAWINGS FOR RELATED INFORMATION.
12. REMOVE ALL DOORS AND DOOR FRAMES SHOWN IN FULLY DEMOLISHED PARTITIONS ONLY,
UNLESS NOTED OTHERWISE.
13. REMOVE ALL RADIATION UNITS, H.V.A.C. RUNS, MECHANICAL UNITS, INFORMATION.
14. REMOVE ALL ELECTRICAL LIGHTING FIXTURES, ELECTRICAL RUNS, ASSOCIATED DEVICES.
REFER TO ELECTRICAL DEMOLITION DRAWINGS FOR RELATED INFORMATION.
15. REFER TO SITE PLANS FOR SITE DEMOLITION NOTES.
16. REFER TO ALL DRAWINGS FOR ADDITIONAL INFORMATION.
17. REMOVE ALL EXISTING FLOOR SYSTEMS I.E. VINYL TILE, SHEET VINYL, CERAMIC TILE, MASTIC, MUD SET, ETC. AT ALL AREAS WHERE A NEW FLOOR IS SCHEDULED. REF. FINISH PLANS &
SCHEDULE. PREP FLOORS TO RECEIVE NEW FINISHES.
18. ALL EXISTING LAY IN CEILING PANELS TO BE REMOVED BY THE ABATEMENT CONTRACTOR
WHERE NEW CEILINGS ARE SCHEDULED. REFER TO ASBESTOS ABATEMENT PLANS AND
REFLECTED CEILING PLANS.
19. REMOVE ALL CEILING GRIDS (CORRIDOR CEILING GRID TO BE REMOVED BY THE ABATEMENT
CONTRACTOR), GYPSUM CEILINGS AND SUSPENSION SYSTEMS AT ALL AREAS WHERE NEW
CEILINGS ARE SCHEDULED. REFER TO REFLECTED CEILING PLANS.
20. REMOVE ALL EXISTING BUILT-IN MILLWORK SHOWN DOTTED INCLUDING SINKS, ASSOCIATED
PLUMBING & ELECTRICAL BACK TO SOURCE OR PANEL AS REQ'D.
21. ALL WINDOW SYSTEMS SCHEDULED FOR DEMOLITION TO BE REMOVED BY THE ABATEMENT
CONTRACTOR.
22. THE DEMOLITION PLANS ARE DIAGRAMMATIC AND INTENDED TO SHOW THE GENERAL
EXTENT OF THE WORK ONLY.
23. THE CONTRACTOR SHALL INCLUDE ALL DEMOLITION WORK REQUIRED TO ACCOMPLISH THE
INTENT OF THE PLANS AND SPECIFICATIONS.
24. ALL DEMOLISHED ITEMS SHALL BE REMOVED FROM BUILDING /SITE UNLESS OTHERWISE
NOTED. COORDINATE WITH OWNER FOR DELIVERY OF ITEMS NOTED TO REMAIN OWNERS
PROPERTY. THE PROJECT SITE/ BUILDING SHALL BE CLEANED OF DEBRIS ON A DAILY BASIS.
CONSTRUCTION MANAGER WILL COORDINATE AND INSTRUCT WHICH
25. CONTRACTOR SHALL BE RESPONSIBLE FOR SHORING AND SUPPORT (TEMPORARY OR
PERMANENT) FOR ALL PORTIONS OF CONSTRUCTION DURING DEMOLITION AND
CONSTRUCTION.
26. ALL ABANDONED MECHANICAL / ELECTRICAL / PLUMBING LINES SHALL BE CAPPED OFF
BEHIND FINISHES, UNLESS OTHERWISE NOTED. REFER TO MECHANICAL / ELECTRICAL /
PLUMBING DRAWINGS FOR ADDITIONAL DEMO. INFORMATION.
27. GENERAL TRADES CONTRACTOR SHALL SAWCUT ALL MASONRY OR CONCRETE OPENINGS
INDICATED. MASONRY SHALL BE TOOTHED IN AND / OR RETURNED TO FINISHED OPENING
ALL OPENINGS WHERE EXISTING CONSTRUCTION HAS BEEN REMOVED, AND WHICH ARE NOT
NOTED TO REMAIN, SHALL BE FILLED AND /OR PATCHED TO MATCH THE ADJACENT EXISTING
OR NEW FINISH, INCLUDING ANY FIRE RATINGS REQUIRED.
28. ALL AREAS OF FLOORS, WALLS AND CEILINGS DISTURBED BY DEMOLITION SHALL BE FILLED, PATCHED OR OTHERWISE REFINISHED TO MATCH EXISTING OR NEW FINISH AS DESIGNATED, INCLUDING ALL REQUIRED RATINGS.
29. CONTRACTOR MUST VERIFY LOCATIONS OF ALL EXISTING STRUCTURAL, MECHANICAL,
PLUMBING & ELECTRICAL ELEMENTS PRIOR TO START OF DEMOLITION.
30. COORDINATE DEMOLITION EFFORTS WITH ASBESTOS ABATEMENT WORK.
31. EXISTING CONDITIONS SHALL BE STUDIED PRIOR TO BIDDING TO FAMILIARIZE YOURSELF
WITH THE BUILDING AND INTENTIONS OF THE FINAL WORK AND THE REQUIRED
DEMOLITION, INCLUDING ALL MECH., ELECT., PLUMB., TECH., STRUCTURAL AND GENERAL
CONSTRUCTION ITEMS REQUIRING REMOVAL.
32. NO ELECTRICAL, TECHNOLOGY WIRING OR PNEUMATIC LINES ARE TO BE ABANDONED IN
PLACE.
33. REFER TO SPECS FOR CUTTING & PATCHING, FLOOR PREP AND SELECTIVE DEMOLITION.
GENERAL DEMOLITION NOTES
DEMOLISH EXISTING LOW WALL AND RADIATOR.
5 5
LIMIT OF FLOOR DEMOLITION
DEMOLISH WALL TO A MINIMUM
HEIGHT OF 7'-0" FOR NEW OPENING.
PROVIDE CLEAN, SMOOTH FINISH.
PATCH AND REPAIR WALL AT LIMIT OF
DEMOLITION TO CREATE FLUSH CONDITION, TYP.
LIMIT OF FLOOR DEMOLITION
LIMIT OF FLOOR DEMOLITION
4'-7 1/2" DEMOLISH WALL TO EXTENT
REQUIRED TO CREATE A 7'-0" HIGH
OPENING
PATCH AND REPAIR WHERE
WALL IS REMOVED. CREATE A
FLUSH AND LIKE NEW
CONDITION
LIMIT OF FLOOR DEMOLITION
APPROXIMATE LIMIT OF FLOOR
DEMOLITION. CAREFULLY REMOVE
EXISTING WOOD THRESHOLD AND
RETAIN FOR REINSTALLATION AFTER
NEW FLOORING IS INSTALLED.
12 2
REMOVE EXISTING
SHELVING IN IT'S ENTIRETY
SHEET NO.
PROFESSIONAL SEAL
21 Talcott Notch Road
Farmington, CT 06032 friar.com
860.678.1291
CONSULTANT
DATE:
SCALE
PROJ. #:
DRAWN:
CHECKED:
As indicated
D1.1
DEMOLITION FLOOR
PLANS
DRIGGS
ELEMENTARY
SCHOOL ELEVATOR
ADDITION
STATE PROJECT NUMBER
77 Woodlawn Terrace
Waterbury, CT 06710
BKH
JMY
2022_049A
1/15/2026
151-0315 LUE
SCALE: 1/4" = 1'-0"
FIRST FLOOR DEMOLITION PLAN
SCALE: 1/4" = 1'-0"
SECOND FLOOR DEMOLITION PLAN
SCALE: 1/4" = 1'-0"
THIRD FLOOR DEMOLITION PLAN
REVISIONS
A3.1
A6.1
A3.1
A3.1
LOBBY
CORRIDOR
TEACHER
WORK ROOM
DOWNSPOUT FROM HOISTWAY ROOF ABOVE,
REFER TO ROOF PLANS
INFILL EXISTING OPENING TO
MATCH ADJACENT CONSTRUCTION
3'-4"…