F5W61608 USPFO Warehouse Ohio Army National Guard Rev. 0 Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
SHEATHING 061600 - 1
SECTION 061600 - SHEATHING
PART 1 - GENERAL
1.1 SUMMARY
1.2 SUMMARY
A. This Section includes the following:
1. Wall sheathing.
2. Building wrap.
3. Sheathing joint-and-penetration treatment.
4. Flexible flashing at openings in sheathing.
1.3 SUBMITTALS
A. Product Data: For each type of process and factory-fabricated product. Indicate component materials and dimensions and include construction and application details.
B. LEED Submittals:
1. Product Data for Credit EQ 4.1: For adhesives, including printed statement of VOC content.
C. Research/Evaluation Reports: For the following:
1. Building wrap.
1.4 QUALITY ASSURANCE
A. Fire-Test-Response Characteristics: For assemblies with fire-resistance ratings, provide materials and construction identical to those of assemblies tested for fire resistance per ASTM E 119 by a testing and inspecting agency acceptable to authorities having jurisdiction.
Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
SHEATHING 061600 - 2
PART 2 - PRODUCTS
2.1 WALL SHEATHING
A. Glass-Mat Gypsum Wall Sheathing: ASTM C 1177/1177M.
1. Product: Provide "Dens-Glass Gold" by G-P Gypsum Corporation.
2. Type and Thickness: Regular, 1/2 inch thick.
2.2 FASTENERS
A. General: Provide fasteners of size and type indicated.
1. For wall sheathing panels, provide fasteners with corrosion-protective coating having a salt-spray resistance of more than 800 hours according to
ASTM B 117.
2.3 WEATHER-RESISTANT SHEATHING PAPER
A. Building Wrap: ASTM E 1677, Type I air retarder; with flame-spread and smoke-developed indexes of less than 25 and 450, respectively, when tested according to ASTM E 84; UV stabilized; and acceptable to authorities having jurisdiction.
1. Available Products: Subject to compliance with requirements, products that may be incorporated into the Work include, but are not limited to, the following:
a. Dow Chemical Company; Styrofoam Weathermate Plus Brand Housewrap.
b. DuPont; Tyvek CommercialWrap.
c. Ludlow Coated Products; Air Stop Housewrap.
d. Pactiv, Inc.; GreenGuard Classic Wrap.
e. Raven Industries Inc.; Rufco-Wrap.
f. Reemay, Inc.; Typar HouseWrap.
2. Water-Vapor Permeance: Not less than 535 g through 1 sq. m of surface in 24 hours per ASTM E 96, Desiccant Method (Procedure A).
B. Building-Wrap Tape: Tape recommended by building-wrap manufacturer.
2.4 SHEATHING JOINT-AND-PENETRATION TREATMENT MATERIALS
A. Sealant for Glass-Mat Gypsum Sheathing Board: Elastomeric silicone joint sealant recommended by sheathing manufacturer.
Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
SHEATHING 061600 - 3
B. Sealant for Glass-Mat Gypsum Sheathing Board: Silicone emulsion sealant complying with ASTM C 834, and recommended by tape and sheathing manufacturers.
C. Sheathing Tape for Glass-Mat Gypsum Sheathing Board: Self-adhering glass-fiber tape, of type recommended by sheathing and tape manufacturers.
2.5 MISCELLANEOUS MATERIALS
A. Flexible Flashing: Self-adhesive, rubberized-asphalt compound, bonded to a high-density, polyethylene film to produce an overall thickness of not less than 0.025 inch.
PART 3 - EXECUTION
3.1 INSTALLATION, GENERAL
A. Securely attach to substrate by fastening as indicated, complying with the following:
1. NES NER-272 for power-driven fasteners.
2. Table 2304.9.1, "Fastening Schedule," in ICC's "International Building Code."
B. Coordinate sheathing installation with flashing and joint-sealant installation so these materials are installed in sequence and manner that exclude exterior moisture.
C. Do not bridge building expansion joints; cut and space edges of panels to match spacing of structural support elements.
3.2 GYPSUM SHEATHING INSTALLATION
A. Comply with GA-253 and with manufacturer's written instructions.
1. Fasten gypsum sheathing to cold-formed metal framing with screws.
2. Install boards with a 3/8-inch gap where non-load-bearing construction abuts structural elements.
3. Install boards with a 1/4-inch gap where they abut masonry or similar materials.
3.3 WEATHER-RESISTANT SHEATHING-PAPER INSTALLATION
A. General: Cover sheathing with weather-resistant sheathing paper as follows:
1. Cut back barrier 1/2 inch on each side of the break in supporting members at expansion- or control-joint locations.
2. Apply barrier to cover vertical flashing with a minimum 4-inch overlap, unless otherwise indicated.
Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
SHEATHING 061600 - 4
B. Building Wrap: Comply with manufacturer's written instructions.
1. Seal seams, edges, fasteners, and penetrations with tape.
2. Extend into jambs of openings and seal corners with tape.
3.4 SHEATHING JOINT-AND-PENETRATION TREATMENT
A. Seal sheathing joints according to sheathing manufacturer's written instructions.
1. Apply elastomeric sealant to joints and fasteners and trowel flat. Seal other penetrations and openings.
2. Apply glass-fiber sheathing tape to glass-mat gypsum sheathing board joints, and apply and trowel silicone emulsion sealant to embed tape in sealant. Apply sealant to exposed fasteners. Seal other penetrations and openings.
3.5 FLEXIBLE FLASHING INSTALLATION
A. Apply flexible flashing where indicated to comply with manufacturer’s written instructions.
1. Lap seams and junctures with other materials at least 4 inches, except that at flashing flanges of other construction, laps need not exceed flange width.
2. Lap flashing over weather-resistant building paper at bottom and sides of openings.
3. Lap weather-resistant building paper over flashing at heads of openings.
4. After flashing has been applied, roll surfaces with a hard rubber or metal roller.
END OF SECTION 061600