087113 automatic door operators.pdf

PDF 17 KB Posted

Attached to
CONSTRUCT USPFO WAREHOUSE
Solicitation number
W91364-09-B-0003
Issued by

About this file

087113 automatic door operators.pdf

View the file

Other files

File Type Posted
ADDENDUM NO 03 USPFO Narrative.pdf PDF
ADDENDUM NO 03 CSMS PH II Narrative.pdf PDF
USPFO_S201W.pdf PDF
E101.pdf PDF
E404.pdf PDF
USPFO_S002W.pdf PDF
262726 wiring devices.pdf PDF
000 USPFO Specs Combined.pdf PDF
220519 meters and gages for plumbing piping.pdf PDF
USPFO_S401W.pdf PDF
013300d attachment submittal register.pdf PDF
095113 acoustical panel ceilings.pdf PDF
224500 emergency plumbing fixtures.pdf PDF
015000 temporary facilities and controls.pdf PDF
072410 polymer-based exterior finish system —
C500.pdf PDF
USPFO_F303W.pdf PDF
USPFO_M401W.pdf PDF
USPFO_FA602W.pdf PDF
OHARNG-USPFO-A-212bW .pdf PDF
079200 joint sealants.pdf PDF
OHARNG-USPFO-A-724W .pdf PDF
I101.pdf PDF
USPFO_P601W.pdf PDF
088500 decorative film for glass.pdf PDF
OHARNG-USPFO-A-816W .pdf PDF
079500 expansion control.pdf PDF
013100 project management and coordination.pdf PDF
OHARNG-USPFO-A-415W .pdf PDF
099113 exterior painting.pdf PDF
USPFO_S212W.pdf PDF
012300 optional bid items.pdf PDF
220548 vibration and seismic controls for plumbing piping and equipment.pdf PDF
220529 hangers and supports for plumbing piping and equipment.pdf PDF
104416 fire extinguishers.pdf PDF
230553 identification for hvac piping and equipment.pdf PDF
263323 central battery equipment.pdf PDF
275116 public address system.pdf PDF
OHARNG-USPFO-G-115W .pdf PDF
OHARNG_USPFO_Q203W.pdf PDF
E502.pdf PDF
018113 sustainable design requirements.pdf PDF
210500 common work results for fire suppression.pdf PDF
OHARNG-USPFO-G-120W .pdf PDF
260543 underground ducts and raceways for electrical systems.pdf PDF
262816 enclosed switches and circuit breakers.pdf PDF
OHARNG-USPFO-A-710W .pdf PDF
E302.pdf PDF
C200.pdf PDF
019113 general commissioning requirements.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F5W61608 USPFO Warehouse Ohio Army National Guard Rev. 0 Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

AUTOMATIC DOOR OPERATORS 087113 - 1

SECTION 087113 - AUTOMATIC DOOR OPERATORS

PART 1 - GENERAL

1.1 SUMMARY

A. Section includes power door operators for swinging doors.

1.2 DEFINITIONS

A. Double Swing Doors: A pair of doors that swing with the two doors moving in opposite directions with a mullion between them; each door functioning as a single swing door.

1.3 SUBMITTALS

A. Product Data: For each type of product indicated.

B. Shop Drawings: For automatic door operators. Include plans, elevations, sections, details, and attachments to other work.

C. Samples: For each exposed product and for each color and texture specified.

D. Product certificates.

E. Field quality-control reports.

F. Maintenance data.

G. Sample warranty.

1.4 QUALITY ASSURANCE

A. Installer Qualifications: Manufacturer's authorized representative who is trained and approved for installation and maintenance of units required for this Project.

B. Certified Inspector Qualifications: Certified by the AAADM.

C. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a testing agency, and marked for intended location and application.

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

AUTOMATIC DOOR OPERATORS 087113 - 2

D. Exit-Door Requirements: Comply with requirements of authorities having jurisdiction for doors with automatic door operators serving as a component of a required means of egress.

E. Preinstallation Conference: Conduct conference at Project site.

1.5 WARRANTY

A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of automatic door operators that fail in materials or workmanship within specified warranty period.

1. Warranty Period: Two years from date of Substantial Completion.

PART 2 - PRODUCTS

2.1 MANUFACTURERS

A. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

1. Besam Automated Entrance Systems, Inc.; an ASSA ABLOY Group company.

2. Horton Automatics; a division of Overhead Door Corporation.

3. LCN Closers; an Ingersoll-Rand company.

4. SARGENT Manufacturing Company; an ASSA ABLOY Group company.

5. Stanley Access Technologies; Division of The Stanley Works.

2.2 MATERIALS

A. Aluminum: Alloy and temper recommended by manufacturer for type of use and finish indicated, complying with standards indicated below:

1. Sheet: ASTM B 209.

2. Extrusions: ASTM B 221.

B. Fasteners and Accessories: Manufacturer's standard corrosion-resistant, nonstaining, nonbleeding fasteners and accessories compatible with adjacent materials.

2.3 AUTOMATIC DOOR OPERATORS, GENERAL

A. General: Provide operators of size recommended by manufacturer for door size, weight, and movement; for condition of exposure; for long-term, maintenance-free operation under normal traffic load for type of occupancy indicated; and complying

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

AUTOMATIC DOOR OPERATORS 087113 - 3

with UL 325. Coordinate operator mechanisms with door operation, hinges, and activation devices.

1. Emergency Breakaway: Where indicated for center-pivoted doors, provide emergency breakaway feature for reverse swing of doors. Equip system to discontinue power to automatic door operator when door is in emergency breakaway position, and to return to closed position after breakaway and automatically reset.

2. Wind Load: Provide door operators on exterior doors that will open and close doors and maintain them in fully closed position when subjected to wind load of as indicated on the drawings.

B. Electromechanical Operating System: Self-contained unit powered by permanent-magnet dc motor; with closing speed controlled mechanically by gear train and dynamically by braking action of electric motor, connections for power and activation-device wiring, and manual operation including spring closing when power is off.

C. Hinges: See Division 8 Section "Door Hardware" for type of hinge for each door that door operator shall accommodate.

D. Housing for Overhead Concealed Operators: Fabricated from minimum 0.125-inch-thick, extruded or formed aluminum and extending full width of door opening including door jambs to conceal door operators and controls. Provide hinged or removable access panels for service and adjustment of door operators and controls. Secure panels to prevent unauthorized access.

E. Cover for Surface-Mounted Operators: Fabricated from 0.125-inch- thick extruded or formed aluminum; manufacturer's standard width; with enclosed end caps, provision for maintenance access, and fasteners concealed when door is in closed position.

F. Brackets and Reinforcements: Manufacturer's standard, fabricated from aluminum with nonstaining, nonferrous shims for aligning system components.

2.4 POWER DOOR OPERATORS

A. Standard: BHMA A156.19.

B. Performance Requirements:

1. Opening Force if Power Fails: Not more than 15 lbf required to release a latch if provided, not more than 30 lbf required to manually set door in motion, and not more than 15 lbf required to fully open door.

2. Entrapment Protection: Not more than 15 lbf required to prevent stopped door from closing or opening.

C. Configuration: Operator to control single swinging door.

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

AUTOMATIC DOOR OPERATORS 087113 - 4

1. Traffic Pattern: Two way .

2. Operator Mounting: Overhead Concealed.

D. Operation: Power opening and spring closing. Provide time delay for door to remain open before initiating closing cycle as required by BHMA A156.19. When not in automatic mode, door operator shall function as manual door closer, with or without electrical power.

E. Operating System: Electromechanical.

F. Microprocessor Control Unit: Solid-state controls.

G. Features:

1. Adjustable opening and closing speed.

2. Adjustable opening and closing force.

3. Adjustable backcheck.

4. Adjustable hold-open time from zero to 30 seconds.

5. Adjustable time delay.

6. Adjustable acceleration.

7. Obstruction recycle.

8. On-off/hold-open switch to control electric power to operator.

H. Exposed Finish: Finish exposed components with Class I, clear anodic finish.

2.5 ACTIVATION DEVICES

A. General: Provide devices in accordance with BHMA standards, for condition of exposure and for long-term, maintenance-free operation under normal traffic load for type of occupancy indicated. Coordinate devices with door operation and door operator mechanisms.

B. Push-Plate Switch: Momentary-contact door control switch with flat push-plate actuator with contrasting-colored, engraved message.

1. Configuration: Square push plate with 4-by-4-inch junction box.

a. Mounting: As indicated on Drawings.

2. Push-Plate Material: Stainless steel as selected by Architect from manufacturer's full range.

3. Message: International symbol of accessibility and "Push to Open."

C. Electrical Interlocks: Unless units are equipped with self-protecting devices or circuits, provide electrical interlocks to prevent activation of operator when door is locked, latched, or bolted.

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

AUTOMATIC DOOR OPERATORS 087113 - 5

2.6 FABRICATION

A. Factory fabricate automatic door operators to comply with indicated standards.

B. Fabricate exterior components to drain water passing joints and condensation and moisture occurring or migrating within operator enclosure to the exterior.

C. Use concealed fasteners to greatest extent possible. Where exposed fasteners are required, use countersunk Phillips flat-head machine screws, finished to match operator.

2.7 ACCESSORIES

A. Signage: As required by cited BHMA standard for the type of operator.

1. Application Process: Door manufacturer's standard process.

2. Provide sign materials with instructions for field application when operators are installed.

2.8 ALUMINUM FINISHES

A. Clear Anodic Finish: AAMA 611, AA-M12C22A41, Class I, 0.018 mm or thicker.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine roughing-in for electrical systems to verify actual locations of power connections before automatic door operator installation.

B. Verify that full-height finger guards are installed at each door with pivot hinges where door has a clearance at hinge side greater than 1/4 inch and less than 3/4 inch with door in any position.

3.2 INSTALLATION

A. General: Install complete automatic door operators according to manufacturer's written instructions, including activation devices, control wiring, and remote power units if any; connection to the building's power supply; and signage.

B. Activation Devices: Install devices and wiring according to manufacturer's written instructions and cited BHMA standard for type of operator and direction of pedestrian

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

AUTOMATIC DOOR OPERATORS 087113 - 6

travel. Connect device wiring according to Division 16 Section "Conductors and Cables."

C. Access-Control System: Connect operators to access-control system as specified in Division 16.

D. Signage: Apply on both sides of each door as required by cited BHMA standard for type of door operator and direction of pedestrian travel.

E. Inspection: Engage Installer's certified inspector to test and inspect automatic door operators and prepare test and inspection reports.

1. Certified inspector shall test and inspect each automatic door operator to determine compliance of installed systems with applicable BHMA standards.

2. Inspection Report: Certified inspector shall submit report in writing to Architect and Contractor within 24 hours after inspection.

3. Work will be considered defective if it does not pass tests and inspections.

F. Adjusting: Adjust automatic door operators to function smoothly and for weathertight closure, and lubricate as recommended by manufacturer; comply with requirements of applicable BHMA standards.

1. Readjust automatic door operators after repeated operation of completed installation equivalent to three days' use by normal traffic (100 to 300 cycles).

G. Demonstration: Engage a certified inspector to train Owner's maintenance personnel to adjust, operate, and maintain automatic door operators.

END OF SECTION 087113