F5W61607 Combined Support Maintenance Shop - Phase II Ohio Army National Guard Rev. 0 Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
JOINT SEALANTS 079200 - 1
SECTION 079200 - JOINT SEALANTS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Silicone joint sealants.
2. Solvent-Release sealants.
3. Latex joint sealants.
4. Acoustical joint sealants.
1.2 PRECONSTRUCTION TESTING
A. Preconstruction Compatibility and Adhesion Testing: Submit to joint-sealant manufacturers eight samples of materials that will contact or affect joint sealants.
Use ASTM C 1087 to determine whether priming and other specific joint preparation techniques are required to obtain rapid, optimum adhesion of joint sealants to joint substrates.
B. Preconstruction Field-Adhesion Testing: Before installing sealants, field test their adhesion to Project joint substrates. Test joint sealants according to Method A, Field- Applied Sealant Joint Hand Pull Tab, in Appendix X1 in ASTM C 1193 or Method A, Tail Procedure, in ASTM C 1521.
1.3 SUBMITTALS
A. Product Data: For each joint-sealant product indicated.
B. LEED Submittal:
1. Product Data for Credit EQ 4.1: For sealants and sealant primers used inside the weatherproofing system, including printed statement of VOC content.
C. Samples: For each kind and color of joint sealant required.
D. Joint-Sealant Schedule: Include the following information:
1. Joint-sealant application, joint location, and designation.
2. Joint-sealant manufacturer and product name.
3. Joint-sealant formulation.
4. Joint-sealant color.
Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
JOINT SEALANTS 079200 - 2
E. Product test reports.
F. Preconstruction compatibility and adhesion test reports.
G. Preconstruction field-adhesion test reports.
H. Field-adhesion test reports.
I. Warranties.
1.4 QUALITY ASSURANCE
A. Testing Agency Qualifications: Qualified according to ASTM C 1021 to conduct the testing indicated.
B. Preinstallation Conference: Conduct conference at Project site.
1.5 WARRANTY
A. Special Installer's Warranty: Manufacturer's standard form in which Installer agrees to repair or replace joint sealants that do not comply with performance and other requirements specified in this Section within specified warranty period.
1. Warranty Period: Two years from date of Substantial Completion.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Manufacturers: Subject to compliance with requirements, provide products by one of the following:
1. Dow Corning Corporation.
2. Pecora Corporation.
3. Sika Corporation; Construction Products Division.
4. Tremco Incorporated.
2.2 MATERIALS, GENERAL
A. VOC Content of Interior Sealants: Provide sealants and sealant primers for use inside the weatherproofing system that comply with the following limits for VOC content when calculated according to 40 CFR 59, Part 59, Subpart D (EPA Method 24):
Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
JOINT SEALANTS 079200 - 3
1. Architectural Sealants: 250 g/L.
2. Sealant Primers for Nonporous Substrates: 250 g/L.
3. Sealant Primers for Porous Substrates: 775 g/L.
B. Stain-Test-Response Characteristics: Where sealants are specified to be nonstaining to porous substrates, provide products that have undergone testing according to ASTM C 1248 and have not stained porous joint substrates indicated for Project.
2.3 SILICONE JOINT SEALANTS
A. Mildew-Resistant Neutral-Curing Silicone Joint Sealant: ASTM C 920.
1. Type: Single component (S).
2. Grade: Nonsag (NS).
3. Class: 25.
4. Uses Related to Exposure: Nontraffic (NT).
5. Uses Related to Joint Substrates: M, G, A, and, as applicable to joint substrates indicated, O.
2.4 LATEX JOINT SEALANTS
A. Latex Joint Sealant: Acrylic latex or siliconized acrylic latex, ASTM C 834, Type OP, Grade NF.
2.5 ACOUSTICAL JOINT SEALANTS
A. Acoustical Joint Sealant: Manufacturer's standard nonsag, paintable, nonstaining latex sealant complying with ASTM C 834. Product effectively reduces airborne sound transmission through perimeter joints and openings in building construction as demonstrated by testing representative assemblies according to ASTM E 90.
2.6 SOLVENT-RELEASE SEALANTS
A. Solvent-Release Sealants: Butyl-Rubber-Based Solvent-Release Joint Sealant:
ASTM C 1085. For use under sill plates.
2.7 JOINT SEALANT BACKING
A. Cylindrical Sealant Backings: ASTM C 1330, Type C (closed-cell material with a surface skin) and of size and density to control sealant depth and otherwise contribute to producing optimum sealant performance.
Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
JOINT SEALANTS 079200 - 4
B. Bond-Breaker Tape: Polyethylene tape or other plastic tape recommended by sealant manufacturer.
2.8 MISCELLANEOUS MATERIALS
A. Primer: Material recommended by joint-sealant manufacturer where required for adhesion of sealant to joint substrates indicated, as determined from preconstruction joint-sealant-substrate tests and field tests.
B. Cleaners for Nonporous Surfaces: Chemical cleaners acceptable to manufacturers of sealants and sealant backing materials.
C. Masking Tape: Nonstaining, nonabsorbent material compatible with joint sealants and surfaces adjacent to joints.
PART 3 - EXECUTION
3.1 PREPARATION
A. Surface Cleaning of Joints: Clean out joints immediately before installing joint sealants to comply with joint-sealant manufacturer's written instructions.
1. Remove laitance and form-release agents from concrete.
2. Clean nonporous joint substrate surfaces with chemical cleaners or other means that do not stain, harm substrates, or leave residues capable of interfering with adhesion of joint sealants.
B. Joint Priming: Prime joint substrates where recommended by joint-sealant manufacturer or as indicated by preconstruction joint-sealant-substrate tests or prior experience. Apply primer to comply with joint-sealant manufacturer's written instructions. Confine primers to areas of joint-sealant bond; do not allow spillage or migration onto adjoining surfaces.
C. Masking Tape: Use masking tape where required to prevent contact of sealant or primer with adjoining surfaces that otherwise would be permanently stained or damaged by such contact or by cleaning methods required to remove sealant smears. Remove tape immediately after tooling without disturbing joint seal.
3.2 INSTALLATION
A. Sealant Installation Standard: Comply with recommendations in ASTM C 1193 for use of joint sealants as applicable to materials, applications, and conditions indicated.
Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
JOINT SEALANTS 079200 - 5
B. Install sealant backings of kind indicated to support sealants during application and at position required to produce cross-sectional shapes and depths of installed sealants relative to joint widths that allow optimum sealant movement capability.
1. Do not leave gaps between ends of sealant backings.
2. Do not stretch, twist, puncture, or tear sealant backings.
3. Remove absorbent sealant backings that have become wet before sealant application and replace them with dry materials.
C. Install bond-breaker tape behind sealants where sealant backings are not used between sealants and backs of joints.
D. Install sealants using proven techniques that comply with the following and at the same time backings are installed:
1. Place sealants so they directly contact and fully wet joint substrates.
2. Completely fill recesses in each joint configuration.
3. Produce uniform, cross-sectional shapes and depths relative to joint widths that allow optimum sealant movement capability.
E. Tooling of Nonsag Sealants: Immediately after sealant application and before skinning or curing begins, tool sealants according to requirements specified in subparagraphs below to form smooth, uniform beads of configuration indicated; to eliminate air pockets; and to ensure contact and adhesion of sealant with sides of joint.
1. Remove excess sealant from surfaces adjacent to joints.
2. Use tooling agents that are approved in writing by sealant manufacturer and that do not discolor sealants or adjacent surfaces.
3. Provide concave joint profile per Figure 8A in ASTM C 1193, unless otherwise indicated.
F. Acoustical Sealant Installation: Comply with ASTM C 919 and with manufacturer's written recommendations.
G. Clean off excess sealant or sealant smears adjacent to joints as the Work progresses by methods and with cleaning materials approved in writing by manufacturers of joint sealants and of products in which joints occur.
3.3 JOINT-SEALANT SCHEDULE
A. Colors of Exposed Joint Sealants: As selected by Architect from manufacturer's full range of colors.
B. Joint-Sealant Application: Exterior vertical and horizontal nontraffic construction joints in cast-in-place concrete.
Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
JOINT SEALANTS 079200 - 6
1. Joint Sealant: Single-component neutral-curing silicone sealant.
C. Joint-Sealant Application: Exterior horizontal traffic isolation and contraction joints in cast-in-place concrete slabs.
1. Joint Sealant: Single-component pourable neutral-curing silicone sealant.
D. Joint-Sealant Application: Exterior vertical control and expansion joints in unit masonry and precast concrete.
1. Joint Sealant: Single-component neutral-curing silicone sealant.
E. Joint-Sealant Application: Exterior perimeter joints between and frames of doors windows and louvers.
1. Joint Sealant: Single-component neutral-curing silicone sealant.
F. Joint-Sealant Application: Vertical control and expansion joints on exposed interior surfaces of exterior walls.
1. Joint Sealant: Single-component neutral-curing silicone sealant or Latex sealant.
G. Joint-Sealant Application: Interior perimeter joints of exterior openings.
1. Joint Sealant: Single-component neutral-curing silicone sealant or Latex sealant.
H. Joint-Sealant Application: Interior joints between plumbing fixtures and adjoining walls, floors, and counters.
1. Joint Sealant: Single-component mildew-resistant neutral-curing silicone sealant.
I. Joint-Sealant Application: Vertical joints on exposed surfaces of interior unit masonry partitions.
1. Joint Sealant: Single-component neutral-curing silicone sealant.
J. Joint-Sealant Application: Perimeter joints between interior wall surfaces and frames of interior doors and windows.
1. Joint Sealant: Latex sealant.
END OF SECTION 079200