F5W61607 Combined Support Maintenance Shop - Phase II Ohio Army National Guard Rev. 0 Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
METAL GRATINGS 055300 - 1
SECTION 055300 - METAL GRATINGS
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Metal bar gratings.
2. Metal frames and supports for gratings.
1.3 SUBMITTALS
A. Product Data: For the following:
1. Metal bar gratings.
2. Clips and anchorage devices for gratings.
1.4 QUALITY ASSURANCE
A. Metal Bar Grating Standards: Comply with NAAMM MBG 531, "Metal Bar Grating Manual" and NAAMM MBG 532, "Heavy-Duty Metal Bar Grating Manual."
PART 2 - PRODUCTS
2.1 FERROUS METALS
A. Steel Plates, Shapes, and Bars: ASTM A 36.
B. Steel Bars for Bar Gratings: ASTM A 36 or steel strip, ASTM A 1011 or ASTM A 1018.
C. Wire Rod for Bar Grating Crossbars: ASTM A 510.
D. Galvanized-Steel Sheet: ASTM A 653, structural quality, Grade 33, with G90 coating.
Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
METAL GRATINGS 055300 - 2
2.2 FASTENERS
A. General: Unless otherwise indicated, provide Type 304 stainless-steel fasteners for exterior use and zinc-plated fasteners with coating complying with ASTM B 633 or ASTM F 1941, Class Fe/Zn 5, at exterior walls. Select fasteners for type, grade, and class required.
2.3 MISCELLANEOUS MATERIALS
A. Welding Rods and Bare Electrodes: Select according to AWS specifications for metal alloy that is welded.
2.4 FABRICATION
A. Cut, drill, and punch material cleanly and accurately. Remove burrs and ease edges to a radius of approximately 1/32 inch unless otherwise indicated. Remove sharp or rough areas on exposed surfaces.
B. Form from materials of size, thickness, and shapes indicated, but not less than that needed to support indicated loads.
C. Fit exposed connections accurately together to form hairline joints.
D. Welding: Comply with AWS recommendations and the following:
1. Use materials and methods that minimize distortion and develop strength and corrosion resistance of base metals.
2. Obtain fusion without undercut or overlap.
3. Remove welding flux immediately.
2.5 METAL BAR GRATINGS
A. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:
1. Alabama Metal Industries Corporation; a Gibraltar Industries company.
2. All American Grating.
3. BarnettBates Corporation.
4. Borden Metal Products (Canada) Limited.
5. Fisher & Ludlow; Division of Harris Steel Limited.
6. Grating Pacific, Inc.
7. IKG Industries; a division of Harsco Corporation.
8. Marwas Steel Co.; Laurel Steel Products Division.
9. Ohio Gratings, Inc.
Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
METAL GRATINGS 055300 - 3
10. Seidelhuber Metal Products; Division of Brodhead Steel Products.
2.6 GRATING FRAMES AND SUPPORTS
A. Frames and Supports for Metal Gratings: Fabricate from metal shapes, plates, and bars of welded construction to sizes, shapes, and profiles indicated and as necessary to receive gratings. Miter and weld connections for perimeter angle frames. Cut, drill, and tap units to receive hardware and similar items.
1. Unless otherwise indicated, fabricate from same basic metal as gratings.
2. Equip units indicated to be cast into concrete or built into masonry with integrally welded anchors. Unless otherwise indicated, space anchors 24 inches o.c. and provide minimum anchor units in the form of steel straps 1-1/4 inches wide by 1/4 inch thick by 8 inches long.
B. Galvanize steel frames and supports.
2.7 STEEL FINISHES
A. Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes.
B. Finish gratings, frames, and supports after assembly.
C. Galvanizing: Hot-dip galvanize items as indicated to comply with ASTM A 153 for steel and iron hardware and with ASTM A 123 for other steel and iron products.
1. Do not quench or apply post galvanizing treatments that might interfere with paint adhesion.
PART 3 - EXECUTION
3.1 INSTALLATION, GENERAL
A. Cutting, Fitting, and Placement: Perform cutting, drilling, and fitting required for installing gratings. Set units accurately in location, alignment, and elevation; measured from established lines and levels and free of rack.
B. Fit exposed connections accurately together to form hairline joints.
1. Weld connections that are not to be left as exposed joints but cannot be shop welded because of shipping size limitations. Do not weld, cut, or abrade the surfaces of exterior units that have been hot-dip galvanized after fabrication and are for bolted or screwed field connections.
Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
METAL GRATINGS 055300 - 4
C. Field Welding: Comply with the following requirements:
1. Use materials and methods that minimize distortion and develop strength and corrosion resistance of base metals.
2. Obtain fusion without undercut or overlap.
3. Remove welding flux immediately.
3.2 INSTALLING METAL BAR GRATINGS
A. General: Install gratings to comply with recommendations of referenced metal bar grating standards that apply to grating types and bar sizes indicated, including installation clearances and standard anchoring details.
B. Attach removable units to supporting members with type and size of clips and fasteners indicated or, if not indicated, as recommended by grating manufacturer for type of installation conditions shown.
3.3 ADJUSTING AND CLEANING
A. Galvanized Surfaces: Clean field welds, bolted connections, and abraded areas and repair galvanizing to comply with ASTM A 780.
END OF SECTION 055300