084113_Aluminum-Framed_Entrances_and_Storefront.pdf

PDF 94 KB Posted

Attached to
Replace Operations and Training Facility
Solicitation number
W912QG-17-B-0005
Issued by

About this file

Aluminum-Framed Entrances and Storefront

View the file

Other files

File Type Posted
QUESTIONS_AND_ANSWERS_-_2.pdf PDF
0007.pdf PDF
0007.pdf PDF
074113.16_Standing_Seam_Metal_Roof_Panels.pdf PDF
072500_FL_-_Weather_Barriers.pdf PDF
0005.pdf PDF
Attendence_Roster.pdf PDF
0004.pdf PDF
2017-08-15_Addendum__2.pdf PDF
0003.pdf PDF
083473_Sound_Control_Door_Assemblies.pdf PDF
_010005_Table_of_Contents.pdf PDF
2017-06-07_Pre-Bid_Addendum__1_Drawings.pdf PDF
087100_Door_Hardware.pdf PDF
Pre-Bid_Addendum__1.pdf PDF
0003.pdf PDF
0002.pdf PDF
Amendment_0001.pdf PDF
Specs.pdf PDF
Drawings.pdf PDF
QUESTIONS_AND_ANSWERS_-_1.pdf PDF
Solicitation.pdf PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS 084113 - 1

SECTION 084113 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary

Conditions and Division 01 Specification Sections, apply to this Section.

1.2 SUMMARY

A. Section Includes:

1. Exterior and interior blast resistant storefront framing and windows.

2. Interior doors and storefront for doors 137 and 155.

B. Related Section

1. Section 084413 “Glazed Aluminum Curtain Walls”.

2. Section 087100 “Door Hardware”.

3. Section 088000 “Glazing”.

1.3 REFERENCES

A. AASSTTMM -- AAmmeerriiccaann SSoocciieettyy ffoorr TTeessttiinngg aanndd MMaatteerriiaallss

1. ASTM F2248 - 09 Standard Practice for Specifying an Equivalent 3-Second Duration

Design Loading for Blast Resistant Glazing Fabricated with Laminated Glass.

B. UUFFCC -- UUnniiffiieedd FFaacciilliittiieess CCrriitteerriiaa

1. UFC 4-010-01, 8 October 2003 (Including change 1 October 2013) “DOD Minimum

Antiterrorism Standards for Buildings”

2. UFC 4-010-02, 8 October 2003 (Including change 1 October 2013) “DOD Minimum

Antiterrorism Standoff Distances for Buildings”

1.4 ACTION SUBMITTALS

A. Product Data: For each type of product.

1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes.

B. LEED Submittals

ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS 084113 - 2

1. MR Credit 4: Recycled Content: Manufacturer’s Product Data indicating percentages by weight of postconsumer and preconsumer recycled content for products having recycled content. Materials/products shall contain the maximum amount of recycled content al-lowed that retains material integrity.

a. Include a statement indicating the cost (excluding labor and equipment to install) for each product permanently installed in the Project and having recycled content. Cost may be provided as lump sum or per item.

2. MR Credit 5: Regional Materials: Provide location of manufacturing facility including name, address and distance between manufacturing facility and the project site. Additionally, provide the extraction locations of raw materials making up the product. Preference shall be given to manufacturers whose manufacturing facilities and the extraction locations of raw materials are within a 500 mile radius of the project site.

a. Include a statement indicating the cost (excluding labor and equipment to install) for each product permanently installed in the Project and having regional material content. Cost may be provided as lump sum or per item.

C. Shop Drawings: For aluminum-framed entrances and storefronts. Include plans, elevations, sections, full-size details, and attachments to other work.

1. Include details of provisions for assembly expansion and contraction and for draining moisture occurring within the assembly to the exterior.

2. Include full-size isometric details of each vertical-to-horizontal intersection of aluminum-framed entrances and storefronts, showing the following:

a. Joinery, including concealed welds.

b. Anchorage.

c. Expansion provisions.

d. Glazing.

e. Flashing and drainage.

3. Show connection to and continuity with adjacent thermal, weather, air, and vapor barriers.

D. Samples for Initial Selection: For units with factory-applied color finishes.

1.5 INFORMATIONAL SUBMITTALS

A. Product Test Reports: For aluminum-framed entrances and storefronts, for tests performed by a qualified testing agency.

B. Quality-Control Program: Developed specifically for Project, including fabrication and installation, according to recommendations in ASTM C 1401. Include periodic quality-control reports.

C. Source quality-control reports.

D. Sample Warranties: For special warranties.

ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS 084113 - 3

1.6 CLOSEOUT SUBMITTALS

A. Maintenance Data: For aluminum-framed entrances and storefronts to include in maintenance manuals.

1.7 QUALITY ASSURANCE

A. Installer Qualifications: An entity that employs installers and supervisors who are trained and approved by manufacturer.

B. Testing Agency Qualifications: Qualified according to ASTM E 699 for testing indicated and accredited by IAS or ILAC Mutual Recognition Arrangement as complying with ISO/IEC

17025.

C. Product Options: Information on Drawings and in Specifications establishes requirements for aesthetic effects and performance characteristics of assemblies. Aesthetic effects are indicated by dimensions, arrangements, alignment, and profiles of components and assemblies as they relate to sightlines, to one another, and to adjoining construction.

1. Do not change intended aesthetic effects, as judged solely by Architect, except with

Architect's approval. If changes are proposed, submit comprehensive explanatory data to

Architect for review.

D. Structural-Sealant Glazing: Comply with ASTM C 1401 for design and installation of storefront systems.

1.8 WARRANTY

A. Special Warranty: Manufacturer agrees to repair or replace components of aluminum-framed entrances and storefronts that do not comply with requirements or that fail in materials or workmanship within specified warranty period.

1. Failures include, but are not limited to, the following:

a. Structural failures including, but not limited to, excessive deflection.

b. Noise or vibration created by wind and thermal and structural movements.

c. Deterioration of metals, metal finishes, and other materials beyond normal weathering.

d. Water penetration through fixed glazing and framing areas.

e. Failure of operating components.

2. Warranty Period: 10 years from date of Substantial Completion.

B. Special Finish Warranty: Standard form in which manufacturer agrees to repair finishes or replace aluminum that shows evidence of deterioration of factory-applied finishes within specified warranty period.

1. Deterioration includes, but is not limited to, the following:

a. Color fading more than 5 Hunter units when tested according to ASTM D 2244.

b. Chalking in excess of a No. 8 rating when tested according to ASTM D 4214.

ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS 084113 - 4

c. Cracking, checking, peeling, or failure of paint to adhere to bare metal.

2. Warranty Period: 20 years from date of Substantial Completion.

PART 2 - PRODUCTS

2.1 PERFORMANCE REQUIREMENTS

A. General Performance: Comply with performance requirements specified, as determined by testing of aluminum-framed entrances and storefronts representing those indicated for this

Project without failure due to defective manufacture, fabrication, installation, or other defects in construction.

1. Aluminum-framed entrances and storefronts shall withstand movements of supporting structure including, but not limited to, story drift, twist, column shortening, long-term creep, and deflection from uniformly distributed and concentrated live loads.

2. Failure also includes the following:

a. Thermal stresses transferring to building structure.

b. Glass breakage.

c. Noise or vibration created by wind and thermal and structural movements.

d. Loosening or weakening of fasteners, attachments, and other components.

e. Failure of operating units.

B. Structural Loads:

1. Wind Loads: As indicated on Drawings.

2. Other Design Loads: As indicated on Drawings.

C. Air Infiltration: Test according to ASTM E 283 for infiltration as follows:

1. Fixed Framing and Glass Area:

a. Maximum air leakage of 0.06 cfm/sq. ft. at a static-air-pressure differential of6.24 lbf/sq. ft..

2. Entrance Doors:

a. Pair of Doors: Maximum air leakage of 1.0 cfm/sq. ft. at a static-air-pressure differential of 1.57 lbf/sq. ft. .

b. Single Doors: Maximum air leakage of 0.5 cfm/sq. ft. at a static-air-pressure differential of 1.57 lbf/sq. ft. .

D. Water Penetration under Static Pressure: Test according to ASTM E 331 as follows:

1. No evidence of water penetration through fixed glazing and framing areas when tested according to a minimum static-air-pressure differential of 20 percent of positive wind-load design pressure, but not less than10 lbf/sq. ft..

E. Seismic Performance: Aluminum-framed entrances and storefronts shall withstand the effects of earthquake motions determined according to ASCE/SEI 7.

ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS 084113 - 5

1. Seismic Drift Causing Glass Fallout: Complying with criteria for passing based on building occupancy type when tested according to AAMA 501.6 at design displacement and 1.5 times the design displacement.

2. Vertical Interstory Movement: Complying with criteria for passing based on building occupancy type when tested according to AAMA 501.7 at design displacement and 1.5 times the design displacement.

F. Blast Resistance: FFoorrccee PPrrootteeccttiioonn ppeerr UUFFCC 44--001100--0011,, 11 OOccttoobbeerr 22001133 ffoorr aa mmaannuuffaaccttuurreerr aapppprroovveedd ffrraammee ssiizzee wwiitthh tthhee ffoolllloowwiinngg tteesstt rreessuullttss::

1. Equivalent Static Design Load: 175 psf applied to the surface of the glazing and frame.

2. Deformation: no more than L/160.

3. Connection Design: equivalent static loads for hardware and glazing stops shall be

10.8psi for glazing panels with a vision area less than or equal to 10.8 square feet and 4.4 psi for glazing panels with a vision area greater than 10.8 square feet but less than or equal to 32 square feet.

44.. Contractor is to provide a certificate of compliance with UFC 4-010-01, 1 October 2013.

55.. AAllll eexxtteerriioorr aanndd iinntteerriioorr sshhaallll bbee bbllaasstt rreessiissttaanntt,, eexxcceepptt ffoorr ddoooorrss 113377 aanndd 115555..

G. Thermal Movements: Allow for thermal movements resulting from ambient and surface temperature changes:

1. Temperature Change: 120 deg F , ambient; 180 deg F , material surfaces.

2. Thermal Cycling: No buckling; stress on glass; sealant failure; excess stress on framing, anchors, and fasteners; or reduction of performance when tested according to AAMA

501.5.

a. High Exterior Ambient-Air Temperature: That which produces an exterior metal-surface temperature of 180 deg F.

b. Low Exterior Ambient-Air Temperature: 0 deg F.

c. Interior Ambient-Air Temperature: 75 deg F.

2.2 MANUFACTURERS

A. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

1. Kawneer North America.

2. TRACO.

3. YKK AP America Inc.

2.3 FRAMING

A. Framing Members: Manufacturer's extruded- or formed-aluminum framing members of thickness required and reinforced as required to support imposed loads.

ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS 084113 - 6

1. Construction: Thermally broken.

2. Glazing System: Retained mechanically with gaskets on two sides and structural sealant on two sides.

3. Glazing Plane: Front.

4. Finish: Color anodic finish (doors 101A, 101B, 102, 160A, 160B) and clear anodic finish

(doors 137 and 155).

5. Fabrication Method: Field-fabricated stick system.

B. Backer Plates: Manufacturer's standard, continuous backer plates for framing members, if not integral, where framing abuts adjacent construction.

C. Brackets and Reinforcements: Manufacturer's standard high-strength aluminum with nonstaining, nonferrous shims for aligning system components.

D. Materials:

1. Aluminum: Alloy and temper recommended by manufacturer for type of use and finish indicated.

a. Sheet and Plate: ASTM B 209 .

b. Extruded Bars, Rods, Profiles, and Tubes: ASTM B 221 .

c. Extruded Structural Pipe and Tubes: ASTM B 429/B 429M.

d. Structural Profiles: ASTM B 308/B 308M.

2. Steel Reinforcement: Manufacturer's standard zinc-rich, corrosion-resistant primer complying with SSPC-PS Guide No. 12.00; applied immediately after surface preparation and pretreatment. Select surface preparation methods according to recommendations in

SSPC-SP COM, and prepare surfaces according to applicable SSPC standard.

a. Structural Shapes, Plates, and Bars: ASTM A 36/A 36M.

b. Cold-Rolled Sheet and Strip: ASTM A 1008/A 1008M.

c. Hot-Rolled Sheet and Strip: ASTM A 1011/A 1011M.

2.4 ENTRANCE DOOR SYSTEMS

A. Entrance Doors: Manufacturer's standard glazed entrance doors for manual-swing operation.

1. Door Construction: 1-3/4-inch overall thickness, with minimum 0.125-inch- thick, extruded-aluminum tubular rail and stile members. Mechanically fasten corners with reinforcing brackets that are deeply penetrated and fillet welded or that incorporate concealed tie rods.

2. Door Design: Medium stile; 3-1/2-inch nominal width.

3. Glazing Stops and Gaskets: Beveled, snap-on, extruded-aluminum stops and preformed gaskets.

a. Provide nonremovable glazing stops on outside of door.

ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS 084113 - 7

2.5 ENTRANCE DOOR HARDWARE

A. Entrance Door Hardware: Hardware not specified in this Section is specified in Section 087100

"Door Hardware."

2.6 GLAZING

A. Glazing: Comply with Section 088000 "Glazing."

B. Weatherseal Sealants: ASTM C 920 for Type S; Grade NS; Class 25; Uses NT, G, A, and O;

chemically curing silicone formulation that is compatible with structural sealant and other system components with which it comes in contact; recommended by structural-sealant, weatherseal-sealant, and structural-sealant-glazed storefront manufacturers for this use.

1. Color: Match structural sealant.

2.7 ACCESSORIES

A. Fasteners and Accessories: Manufacturer's standard corrosion-resistant, nonstaining, nonbleeding fasteners and accessories compatible with adjacent materials.

1. Use self-locking devices where fasteners are subject to loosening or turning out from thermal and structural movements, wind loads, or vibration.

2. Reinforce members as required to receive fastener threads.

3. Use exposed fasteners with countersunk Phillips screw heads, finished to match framing system.

B. Anchors: Three-way adjustable anchors with minimum adjustment of 1 inch that accommodate fabrication and installation tolerances in material and finish compatible with adjoining materials and recommended by manufacturer.

1. Concrete and Masonry Inserts: Hot-dip galvanized cast-iron, malleable-iron, or steel inserts complying with ASTM A 123/A 123M or ASTM A 153/A 153M requirements.

C. Concealed Flashing: Manufacturer's standard corrosion-resistant, nonstaining, nonbleeding flashing compatible with adjacent materials.

D. Bituminous Paint: Cold-applied asphalt-mastic paint complying with SSPC-Paint 12 requirements except containing no asbestos, formulated for 30-mil thickness per coat.

2.8 FABRICATION

A. Form or extrude aluminum shapes before finishing.

B. Weld in concealed locations to greatest extent possible to minimize distortion or discoloration of finish. Remove weld spatter and welding oxides from exposed surfaces by descaling or grinding.

C. Fabricate components that, when assembled, have the following characteristics:

1. Profiles that are sharp, straight, and free of defects or deformations.

2. Accurately fitted joints with ends coped or mitered.

ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS 084113 - 8

3. Physical and thermal isolation of glazing from framing members.

4. Accommodations for thermal and mechanical movements of glazing and framing to maintain required glazing edge clearances.

5. Provisions for field replacement of glazing from interior for vision glass and exterior for spandrel glazing or metal panels.

6. Fasteners, anchors, and connection devices that are concealed from view to greatest extent possible.

D. Mechanically Glazed Framing Members: Fabricate for flush glazing without projecting stops.

E. Structural-Sealant-Glazed Framing Members: Include accommodations for using temporary support device to retain glazing in place while structural sealant cures.

F. Storefront Framing: Fabricate components for assembly using shear-block system, screw-spline system, or head-and-sill-receptor system with shear blocks at intermediate horizontal members.

G. Entrance Door Frames: Reinforce as required to support loads imposed by door operation and for installing entrance door hardware.

H. Entrance Doors: Reinforce doors as required for installing entrance door hardware.

I. Entrance Door Hardware Installation: Factory install entrance door hardware to the greatest extent possible. Cut, drill, and tap for factory-installed entrance door hardware before applying finishes.

J. After fabrication, clearly mark components to identify their locations in Project according to

Shop Drawings.

2.9 ALUMINUM FINISHES

A. Color Anodic Finish: AAMA 611, AA-M12C22A42/A44, Class I, 0.018 mm or thicker.

1. Color: Dark bronze (doors 101A, 101B, 102, 160A, 160B).

2. Color: As selected by Government from full range of industry colors and color densities.

B. Clear Anodic Finish (doors 137 and 155): AAMA 611, AA-M12C22A41, Class I, 0.018 mm or thicker.

2.10 SOURCE QUALITY CONTROL

A. Structural Sealant: Perform quality-control procedures complying with ASTM C 1401 recommendations including, but not limited to, assembly material qualification procedures, sealant testing, and assembly fabrication reviews and checks.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine areas, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of the Work.

ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS 084113 - 9

B. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 PREPARATION

A. Prepare surfaces that are in contact with structural sealant according to sealant manufacturer's written instructions to ensure compatibility and adhesion. Preparation includes, but is not limited to, cleaning and priming surfaces.

3.3 INSTALLATION

A. General:

1. Comply with manufacturer's written instructions.

2. Do not install damaged components.

3. Fit joints to produce hairline joints free of burrs and distortion.

4. Rigidly secure nonmovement joints.

5. Install anchors with separators and isolators to prevent metal corrosion and electrolytic deterioration and to prevent impeding movement of moving joints.

6. Seal perimeter and other joints watertight unless otherwise indicated.

B. Metal Protection:

1. Where aluminum is in contact with dissimilar metals, protect against galvanic action by painting contact surfaces with materials recommended by manufacturer for this purpose or by installing nonconductive spacers.

2. Where aluminum is in contact with concrete or masonry, protect against corrosion by painting contact surfaces with bituminous paint.

C. Set continuous sill members and flashing in full sealant bed as specified in Section 079200

"Joint Sealants" to produce weathertight installation.

D. Install components plumb and true in alignment with established lines and grades.

E. Install operable units level and plumb, securely anchored, and without distortion. Adjust weather-stripping contact and hardware movement to produce proper operation.

F. Install glazing as specified in Section 088000 "Glazing."

G. Install weatherseal sealant according to Section 079200 "Joint Sealants" and according to sealant manufacturer's written instructions to produce weatherproof joints. Install joint filler behind sealant as recommended by sealant manufacturer.

H. Entrance Doors: Install doors to produce smooth operation and tight fit at contact points.

1. Exterior Doors: Install to produce weathertight enclosure and tight fit at weather stripping.

2. Field-Installed Entrance Door Hardware: Install surface-mounted entrance door hardware according to entrance door hardware manufacturers' written instructions using concealed fasteners to greatest extent possible.

ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS 084113 - 10

3.4 ERECTION TOLERANCES

A. Erection Tolerances: Install aluminum-framed entrances and storefronts to comply with the following maximum tolerances:

1. Plumb: 1/8 inch in 10 feet ; 1/4 inch in 40 feet .

2. Level: 1/8 inch in 20 feet ; 1/4 inch in 40 feet .

3. Alignment:

a. Where surfaces abut in line or are separated by reveal or protruding element up to

1/2 inch wide, limit offset from true alignment to 1/16 inch .

b. Where surfaces are separated by reveal or protruding element from 1/2 to 1 inch wide, limit offset from true alignment to 1/8 inch .

c. Where surfaces are separated by reveal or protruding element of 1 inch wide or more, limit offset from true alignment to 1/4 inch .

4. Location: Limit variation from plane to 1/8 inch in 12 feet ; 1/2 inch over total length.

3.5 MAINTENANCE SERVICE

A. Entrance Door Hardware:

1. Maintenance Tools and Instructions: Furnish a complete set of specialized tools and maintenance instructions as needed for Owner's continued adjustment, maintenance, and removal and replacement of entrance door hardware.

2. Initial Maintenance Service: Beginning at Substantial Completion, provide six months' full maintenance by skilled employees of entrance door hardware Installer. Include quarterly preventive maintenance, repair or replacement of worn or defective components, lubrication, cleaning, and adjusting as required for proper entrance door hardware operation at rated speed and capacity. Use parts and supplies that are the same as those used in the manufacture and installation of original equipment.

3.6 ENTRANCE DOOR HARDWARE SETS

A. The hardware sets represent the design intent and direction of the Government and architect.

They are a guideline only and should not be considered a detailed hardware schedule.

Discrepancies, conflicting hardware and missing items should be brought to the attention of the

Government with corrections made prior to the bidding process. Omitted items not included in a hardware set should be scheduled with the appropriate additional hardware required for proper application and functionality.

END OF SECTION 084113