Misc_Drawings_Part8.pdf

PDF 10 MB Posted

Attached to
Amend 0003 Federal contract opportunity
Solicitation number
W912P815B0046
Issued by
Department of the Army Corps of Engineers Engineering District New Orleans

About this file

Drawings Misc

View the file

Other files for this federal contract opportunity

Other files attached to Amend 0003, newest first.
File Type Posted
Drawing_for_MA-1_(_11-12-04)_New_Foundation_Part8.pdf PDF
Batch__2_Questions-Replies_W912P8-15-B-0046_(Amend0003).pdf PDF
Drawing_for_MA-1_(_11-12-04)_New_Foundation_Part9.pdf PDF
Drawing_for_MA-1_(_11-12-04)_New_Foundation_Part5.pdf PDF
Drawing_for_MA-1_(_11-12-04)_New_Foundation_Part10.pdf PDF
Drawing_for_MA-1_(_11-12-04)_New_Foundation_Part2.pdf PDF
SF30_Amend_0002Corrected.pdf PDF
QASP_Performance_Work_Statement__replacement.pdf PDF
Drawings_LAFCO_441-25_Welding_Sch_ _Details.pdf PDF
Drawings_LAFCO_441-16B_A_C_Electrical_System.pdf PDF
Drawings_LAFCO_441-12B_Fixed_CO2_Sys.pdf PDF
Drawings_LAFCO_441-3_Scantlings_and_Inboard_Profile.pdf PDF
Drawings_Launch_Edge_Water__914-433-009_Rigging_ _Tackle_Assy.pdf PDF
Drawings_LAFCO_441-23_Bumper_Details.pdf PDF
Drawings_LAFCO_441-19_Fuel_Tank.pdf PDF
Drawings_Launch_Edge_Water__914-433-005_Gen_Notes_and_BOM.pdf PDF
Drawings_11-04-01_opt.pdf PDF
Drawings_Launch_Edge_Water_914-433-000_General_Arrangement.pdf PDF
Drawings_Launch_Edge_Water__914-433-011_Davit_Arm_Installation _Winch_and_Misc_Details.pdf PDF
Drawings_Launch_Edge_Water__914-433-003_Support_Frame_Weldment.pdf PDF
Avondale_Drawings_combined_Part12.pdf PDF
Avondale_Drawings_combined_Part2.pdf PDF
Avondale_Drawings_combined_Part54.pdf PDF
Avondale_Drawings_combined_Part43.pdf PDF
Avondale_Drawings_combined_Part37.pdf PDF
Avondale_Drawings_combined_Part63.pdf PDF
Avondale_Drawings_combined_Part59.pdf PDF
Avondale_Drawings_combined_Part69.pdf PDF
Avondale_Drawings_combined_Part35.pdf PDF
Avondale_Drawings_combined_Part9.pdf PDF
Avondale_Drawings_combined_Part38.pdf PDF
Avondale_Drawings_combined_Part62.pdf PDF
Avondale_Drawings_combined_Part53.pdf PDF
Avondale_Drawings_combined_Part64.pdf PDF
Avondale_Drawings_combined_Part52.pdf PDF
Avondale_Drawings_combined_Part70.pdf PDF
Avondale_Drawings_combined_Part49.pdf PDF
Avondale_Drawings_combined_Part4.pdf PDF
Avondale_Drawings_combined_Part58.pdf PDF
Avondale_Drawings_combined_Part17.pdf PDF
Misc_Drawings_Part9.pdf PDF
Misc_Drawings_Part2.pdf PDF
Misc_Drawings_Part1.pdf PDF
Misc_Drawings_Part7.pdf PDF
Misc_Drawings_Part6.pdf PDF
Dredge_Technology_Drawings_Part3.pdf PDF
Dredge_Technology_Drawings_Part5.pdf PDF
Dredge_Technology_Drawings_Part8.pdf PDF
Section_J_Attachment_List_.pdf PDF
W912P8-15-B-0046.pdf PDF
Show all 50

Amend 0003 has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Electrical Snap action electrical switch recognized by Underwriters’ Laboratories, Inc. and CSA International

Electrical Connection ¹⁄₂ NPT female conduit connection with terminal block

Pressure Connection Wetted Material 1 ¹⁄₄ NPT Female

Temperature Range* Ambient: -40°F to +180°F

(-40°C to +82°C) Media: -40°F to +300°F

(-40°C to +149°C)

*Temperature limits change with O-Ring selection

Adjustment Concealed wrench flat adjustment with range scale

Shipping Weight Approximately 3 pounds

Neo-Dyn® Series 200P Pressure Switch/ Internal Adjustment

Operating Pressure Data

Standard Specifications Ordering Sequence — Select desired option for each category

DESCRIPTION

Versatile Nega-Rate® Belleville disc spring pressure switch for a wide range of applications. Series 200P (piston sensor) for hydraulic applications up to 10000 psig system pressure.

Weather Proof (NEMA 4 and 13)

When factory presetting is desired, stipulate set point, increasing or decreasing

Insert available option number or letter designation as required

Series Wetted Material Adjustable Range Electrical Form Enclosure Miscellaneous

200P

OPTIONS

Wetted Material 1 Aluminum port and piston, Teflon seal and Buna-N O-Ring Adjustable Range 2 14 psig dec. to 220 psig inc. (1.0 bar dec. to 15.2 bar inc.)

3 150 psig dec. to 1500 psig inc. (10.3 bar dec. to 103.4 bar inc.)

6 375 psig dec. to 3000 psig inc. (25.9 bar dec. to 206.9 bar inc.)

8 800 psig dec. to 10000 psig inc. (55.2 bar dec. to 689.5 bar inc.)

Electrical Form C 15 amp at 125 or 250 VAC; ¹⁄₈ hp at 125 VAC; ¹⁄₄ hp at 250 VAC;

.5 amp resistive, .04 amp inductive at 125 VDC CC 11 amp, ¹⁄₄ hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC;

.5 amp resistive at 125 VDC Z 15 amp at 125 or 250 VAC; ¹⁄₄ hp at 125 VAC; ¹⁄₂ hp at 250 VAC; 1 amp resistive, .5 amp inductive at 125 VDC Enclosure 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 Miscellaneous A Epoxy paint exterior — extra protection for severe environments B Viton O-Ring C EPR O-Ring E ⁷⁄₁₆" - 20 SAE port L Neon indicator light — 115 VAC M Gold electrical contacts for extremely low current applications P 5-Pin Brad Harrison connector (Reduce AC electrical rating to 8 amps)

— (Not for CC3 Electrical) W Stainless steel screws — exterior X UL and CSA Certified with CE Mark (Not available with L or P option) Special (Consult representative or factory)

Non-catalog adjustable range and/or set point, deadband and proof pressure Operating temperature capability from -65°F to +400°F Manual reset — decreasing only (available in C3 only) 10 amps 125 VDC electrical rating

Adjustable Range

Number

Deadband† (approximate) Maximum Recommended System Pressure

10000*

Proof Pressure

10000 10000

15000**

Adjustable Set Point Range

Increasing 20 to 220

200 to 1500 500 to 3000

1000 to 10000

Decreasing 14 to 202

150 to 1275 375 to 2700 800 to 9000

All values given in psig.

†The deadband increases as the adjustable set point is increased.

*Diminished safety factor equal to approximately 2:1.

**Diminished safety factor equal to approximately 1.3:1.

13 C 3 _

Ordering Procedure Example

Max.

Min.

HPU Item #32

Hydraulic Power Unit - Item #32Hydraulic Power Unit - Item #32

8-1028-102

7.0 Max.

3.6

.82

1.72

Conduit Connection

¹⁄₂ NPT

Pessure Port

¹⁄₄ NPT2.72

3.50

2.72

.37

3.50

.265 Dia.

Mtg. Holes (2 places)

1.18

2.85 Max.

1.12 .50

Snap Action Electrical Element

Terminal Strip

Adjustment

Actuator Minimum Bearing Points

Teflon and O-Ring Seal

Piston Pressure Port

Negative Rate Belleville Disc Spring

Series 200PField Adjustable 14 to 10000 psig

Envelope Dimensions

Electrical Form

Basic Principles of Design

28150 Industry Drive, Valencia, CA 91355 Tel: 661-295-4000 Fax: 661-294-1750

FORM "C"

(SPDT)

RED

BRN

BLU

NC1

INC

P

C1

NO1

GRN

SCREW

FORM "CC"

(DPDT)

RED

BRN

BLU

BLK

YEL

VIO

NC1

INC

P

C1

NO1

NC2

C2

NO2

GRN

SCREW

Form #109-rev.a

FORM "Z"

(DOUBLE BREAK)

BLKRED NC NC

BLU VIONO NO

INC

P

GRN

SCREW

HPU Item #32

Hydraulic Power Unit - Item #32Hydraulic Power Unit - Item #32

8-1038-103

50 For pricing info, call 1-888-WIKA-USA or visit www.wika.com

Panel Builder Gauge

All Stainless Steel Construction

Glycerine Filled Case

The Type 233.55 LBM is specifically designed and manufactured to exact panel builder requirements. With exclusive features, it is ideal when used for panel mount gauges in the oil and gas, refinery, petrochemical, and food & beverage industries.

Industrial Gauges Type 233.55

Datasheet: 233.55

Standard Features Nominal Case Size: 2½" (63 mm)

Case Material: 304 stainless steel with off-set vent plug

Front Flange: Stainless steel

Wetted Parts: 316 SS

Window Type & Material: Safety glass

Dial Material: White aluminum Liquid Fillable Gauge: Standard

Restrictor: Standard

Pointer Material/Type: Black aluminum

Accuracy: 2/1/2% of span ASME B40.100 Grade A

Connection Locations: LBM (lower back mount)

Media Operating Temperature: Max. 212°F

Ambient Operating Temperature: -4°F to 140°F (-20°C to 160°C) maximum;

-40°F to 140°F w/silicone case fill

Items without part numbers are available - consult factory.

Type 233.55

Datasheet 233.55

Size 2½"

Conn. Size ¼" NPT

Connection LBM/FF

Press. Scale PSI PSI/BAR1 PSI/KPA PSI/KG/CM2

30" Hg 4282811 4283078 4283337 4283591

30"-0-15 psi 4282829 4283086 4283345 4283604

30"-0-30 psi 4282837 4283094 4283354 4283613

30"-0-60 psi 4282845 4283107 4283362 4283621

30"-0-100 psi 4282854 4283115 4283370 4283639

30"-0-160 psi 4282862 4283124 4283388 4283647

30"-0-200 psi 4282870 4283133 4283396 4283655

15 psi 4282888 4283141 4283400 4283664

30 psi 4282896 4283159 4283418 4283672

60 psi 4282900 4283167 4283426 4283680

100 psi 4282918 4283175 4283434 4283698

160 psi 4282926 4283184 4283443 4283702

200 psi 4282934 4283192 4283451 4283710

300 psi 4282943 4283204 4283469 4283728

400 psi 4282951 4283214 4283477 4283736

600 psi 4282969 4283222 4283485 4283744

800 psi 4282977 4283230 4283494 4283753

1,000 psi 4282985 4283248 4283507 4283761

1,500 psi 4282994 4283256 4283515 4283779

2,000 psi 4283000 4283264 4283524 4283787

3,000 psi 4283018 4283273 4283532 4283795

5,000 psi 4283026 4283281 4283540 4283809

6,000 psi 4283034 4283299 4283558 4283817

10,000 psi 4283044 4283303 4283566 4283825

15,000 psi 4283052 4283311 4283574 4283834

20,000 psi 4283060 4283329 4283583 4283842

¹"PSI/BAR" denotes dual scale; PSI outside in black, BAR inside in red.

2"PSI/KG/CM²" denotes dual scale; PSI outside in black, KG/CM² inside in red.

Note: Vacuum scale: 30" Hg outside in black; 760 mm Hg inside in red.

Note: Stock items shown in bold, blue print.

Additional accessories available -see "Accessories" section in back of catalog

HPU Item #33-37Hydraulic Power Unit - Item #33-37Hydraulic Power Unit - Item #33-37

8-1048-104

STAUFF

STA

STA

Test hose with swivel nut

Protective cap

Test coupling

T8

Test 20 Type SKK Connection Thread M 16 x 2

T E

S T

The complete STAUFF-TEST-20-Type-SKK range is also available with hexagonal protection cap made of steel or plastic protection cap

Fast Coupling for:

• Monitoring and control of pressure

• Venting

• Sampling Fluids

Advantages:

• Coupling at system pressure level

• Connection is leakproof before piston valve is open

• Simple connection to measurement, control and switching devices

• Self locking metal protective cap

• Minimizes introduction of contamination to hydraulic systems

Working Pressure:

• Max. working pressure 9000 PSI (630 bar) For SKK type G, K and S the recommended working pressure of fitting manufacturer should be noted

• Connection under pressure up to 5800 PSI (400 bar) max.

Materials:

• Metal parts: Steel, Stainless Steel on request

• Seals:

Standard V = FPM-VITON Temperature range – 4˚F to +392˚F (– 20˚ C to + 200˚ C)

Optional P = NBR-BUNA Temperature range – 4˚F to +195˚F

(–20˚ C to + 90˚C)
E=EPDMEthylenePropylene(forBrakeFluid)

Temperature range – 40˚F to +302˚F (– 40˚ C to + 150˚ C)

•Hose: Polyamide Temperature range –31˚F to +212˚F
(–35˚C to +100˚ C)

Media:

•Suitableforhydraulicoilsandotherlowviscositymineral
basedfluids(Checkcompatibilityofsealmaterial)

• For use with other liquid or gaseous media please consult STAUFF for details

HPU Item #39Hydraulic Power Unit - Item #38 - SKK20-716 UNF VE C6FHydraulic Power Unit - Item #38 - SKK20-716 UNF VE C6F

8-1058-105

G d1 t 1 t 2

30°

0.

2.

d1

G

90° t 1 t 2 a d1

G

90° t 1 t 2 a

G

90° t 1 t 2

G d1

1, a t 1 t 2

12° d2

17 10

0.67" 0.4"

STAUFF

hM 16

Hex

G

T9

Test 20 Type SKK Connection Thread M 16 x 2

T E

S T

M8 x 1 SKK 20 – M8 x 1 – PA SKK 20 – M8 x 1 – VA O-Ring Type A

M10 x 1 SKK 20 – M10 x 1 – PA SKK 20 – M10 x 1 – VA O-Ring Type A

M12 x 1,5 SKK 20 – M12 x 1,5 – PC SKK 20 – M12 x 1,5 – VC O-Ring Type C

M14 x 1,5 SKK 20 – M14 x 1,5 – PB SKK 20 – M14 x 1,5 – VB Metal joint Type B

M16 x 1,5 SKK 20 – M16 x 1,5 – PB SKK 20 – M16 x 1,5 – VB Metal joint Type B

G 1/8 SKK 20 – G 1/8 – PC SKK 20 – G 1/8 – VC O-Ring Type C

G 1/4 SKK 20 – G 1/4 – PB SKK 20 – G 1/4 – VB Metal joint Type B

G 1/4 SKK 20 – G 1/4 – PC SKK 20 – G 1/4 – VC O-Ring Type C

G 3/8 SKK 20 – G 3/8 – PB SKK 20 – G 3/8 – VB Metal joint Type B

R 1/8 taper SKK 20 – R 1/8 K-PD SKK 20 – R 1/8 K-VD Taper Type D

R 1/4 taper SKK 20 – R 1/4 K-PD SKK 20 – R 1/4 K-VD Taper Type D

1/8 NPT SKK 20 – 1/8 NPT-PD SKK 20 – 1/8 NPT-VD Taper Type D

1/4 NPT SKK 20 – 1/4 NPT-PD SKK 20 – 1/4 NPT-VD Taper Type D

5/16 – 24 UNF SKK 20 – 5/16 UNF-PE SKK 20 – 5/16 UNF-VE O-Ring Type E

7/16 – 20 UNF SKK 20 – 7/16 UNF-PE SKK 20 – 7/16 UNF-VE O-Ring Type E

1/2 – 20 UNF SKK 20 – 1/2 UNF-PE SKK 20 – 1/2 UNF-VE O-Ring Type E

9/16 – 18 UNF SKK 20 – 9/16 UNF-PE SKK 20 – 9/16 UNF-VE O-Ring Type E

Thread h Hex Order No.

G Seal Type NBR (BUNA) FPM (VITON) (see below) (Standard)

Test Coupling with Protective Cap SKK

To order hexagonal protection cap, add “SK” to part number. To order Plastic Protection cap, add “KK” to part number.

Other port connections and seals on request.

Port Connections and Seals

Type A Type B Type C Type D Type E (ISO 6149)

G d1 d2 t1 t2 a G t1 t2 G d1 t1 t2 a G d1 t1 t2 a G d1 t1 t2

5/16 – 24 UNF

7/16 – 20 UNF

1/2 – 20 UNF

9/16 – 18 UNF

R 1/8 taper

R 1/4 taper

1/8 NPT

1/4 NPT

M12 x 1,5

G 1/8

G 1/4

M14 x 1,5

M16 x 1,5

G 1/4

G 3/8

M8 x 1

M10 x 1 mm

1.45

1.45

1.45

1.45

1.45

1.53

1.45

1.45

1.45

1.45

1.41

1.41

1.38

1.50

1.50

1.50

1.45 in

.67

.67

.67

.75

.87

.67

.75

.75

.87

.67

.67

.67

.67

.67

.67

.67

.75 mm in

0.37

9,5 + 0,1

11,5 + 0,1

0.45 mm in mm in

0.43

15,5

0.61

0.47

16,5

0.65 mm in

0.79

0.87

0.75

0.91 mm in mm in mm in

0.47

18,5

0.73

1,5

0.06

0.47

18,5

0.73

1,5

0.06

0.47

18,5

0.73

1,5

0.06

0.47

18,5

0.73

1,5

0.06 mm in

0.71

0.59

0.75 mm in mm in mm in mm in mm in

5,5

0.22

9,5

0.37 8,5

0.33

13,5

0.53 6,9

0.27

11,6

0.46

0.39

16,4

0.65

0.06

0.47

18,5

0.73

1,5

0.31

0.51

1,0

0.04

0.47

18,5

0.73

1,5

0.06 mm in

9,1

0.36 12,4

0.49

0.55 mm in mm in mm in

0.47

0.67

0.39

0.83

11,5

0.45

0.55

0.91

11,5

0.45

0.55 mm in

0.07

1,9

2,4

0.09 2,4

0.09 15,6

0.61

0.98

12,7

0.50

15,5

0.61

2,5

0.10 mm in

(Add C6F for Standard Finish)

HPU Item #39Hydraulic Power Unit - Item #38 - SKK20-716 UNF VE C6FHydraulic Power Unit - Item #38 - SKK20-716 UNF VE C6F

8-1068-106

SW17

Ød l 3 1.

1.

SW17

l 3

Ød

STAUFF STAUFF

STAUFF

SW17

SW2

ød

I 2

1.

STAUFF

SW 1

SW 2

SW17 h ød

T10

Test 20 Type SKK Connection Thread M 16 x 2

T E

S T

PN l2 l3 h SW 1 SW 2 Order No.*

Series PSI Pipe (Bar) Ød Type G Type K Type S

Test Coupling SKK (compression ring fittings acc. to DIN 2353) - Metric Tubing

* For ordering BUNA seals please replace “V” with “P”

* For EPDM seals replace “V” with “E”

Type G Test coupling complete with straight fitting

Type S Test coupling for compression ring assembly

Type K Test coupling for 24˚ cone fittings

15,5 0.61

15,5 0.61

16,5 0.65

17,5 0.69

0.83

19,5 0.77

20,5 0.81

0.98

1.18

1.22

14,5 0.57

16,5 0.65

16,5 0.65

17,5 0.69

19,5 0.77

0.71

0.94

1.02

1.18

1.34

0.79

0.79

0.87

0.87

0.98

1.10

1.18

1.26

1.65

1.77

0.79

0.79

0.87

0.87

0.87

1.10

1.18

1.42

1.61

1.89

1.93

1.93

1.93

1.97

2.05

2.09

2.17

57,5 2.26

2.36

64,5 2.54

1.93

1.93

1.93

1.93

50,5 1.99

2.05

2.17

57,5 2.26

2.36

64,5 2.54

0.94

0.94

0.94

1.06

1.18

1.26

1.42

1.61

1.81

2.17

0.94

0.94

0.94

0.94

1.06

1.18

1.42

1.61

1.81

2.17

0.55

0.67

0.75

0.87

1.06

1.26

1.42

1.61

1.97

2.36

0.67

0.75

0.87

0.94

1.06

1.18

1.42

1.81

1.97

2.36 mm in mm in mm in mm in mm in

6 SKK 20 – 6 L–VG SKK 20 – 6 L–VK SKK 20 – 6–VS

8 SKK 20 – 8 L–VG SKK 20 – 8 L–VK SKK 20 – 8–VS

4500 10 SKK 20 – 10 L–VG SKK 20 – 10 L–VK SKK 20 – 10–VS

(315) 12 SKK 20 – 12 L–VG SKK 20 – 12 L–VK SKK 20 – 12–VS

L

15 SKK 20 – 15 L–VG SKK 20 – 15 L–VK SKK 20 – 15–VS

18 SKK 20 – 18 L–VG SKK 20 – 18 L–VK SKK 20 – 18–VS

22 SKK 20 – 22 L–VG SKK 20 – 22 L–VK SKK 20 – 22–VS

2300 28 SKK 20 – 28 L–VG SKK 20 – 28 L–VK SKK 20 – 28–VS

(160) 35 SKK 20 – 35 L–VG SKK 20 – 35 L–VK SKK 20 – 35–VS

42 SKK 20 – 42 L–VG SKK 20 – 42 L–VK SKK 20 – 42–VS

6 SKK 20 – 6 S–VG SKK 20 – 6 S–VK SKK 20 – 6–VS

8 SKK 20 – 8 S–VG SKK 20 – 8 S–VK SKK 20 – 8–VS

9100 10 SKK 20 – 10 S–VG SKK 20 – 10 S–VK SKK 20 – 10–VS

(630) 12 SKK 20 – 12 S–VG SKK 20 – 12 S–VK SKK 20 – 12–VS

S

14 SKK 20 – 14 S–VG SKK 20 – 14 S–VK SKK 20 – 14–VS

16 SKK 20 – 16 S–VG SKK 20 – 16 S–VK SKK 20 – 16–VS

5800 20 SKK 20 – 20 S–VG SKK 20 – 20 S–VK SKK 20 – 20–VS

(400) 25 SKK 20 – 25 S–VG SKK 20 – 25 S–VK SKK 20 – 25–VS

30 SKK 20 – 30 S–VG SKK 20 – 30 S–VK SKK 20 – 30–VS

(315)

38 SKK 20 – 38 S–VG SKK 20 – 38 S–VK SKK 20 – 38–VS

(Add C6F for Standard Finish)

HPU Item #39Hydraulic Power Unit - Item #38 - SKK20-716 UNF VE C6FHydraulic Power Unit - Item #38 - SKK20-716 UNF VE C6F

8-1078-107

Atlantic Industrial Technologies

9 ELECTRICAL DATASHEETS

Circuit Protectionw w w . a u t o m a t i o n d i r e c t . c o m / c i r c u i t - p r o t e c t i o n e31–5

Company Information

Systems Overview

Programmable Controllers

Field I/O

Software

C-more & other HMI

Drives

Soft Starters

Motors & Gearbox

Steppers/ Servos

Motor Controls

Proximity Sensors

Photo Sensors

Limit Switches

Encoders

Current Sensors

Pressure Sensors

Temperature Sensors

Pushbuttons/ Lights

Process

Relays/ Timers

Comm.

Terminal Blocks & Wiring

Power

Circuit Protection

Enclosures

Tools

Pneumatics

Safety

Appendix

Product Index

Part # Index

Volume 14

UL489 or UL1077?

What are your Circuit Protection Requirements?

An understanding of circuit types and circuit protection products is critical to ensure their proper application.

See NEC Sections 100, 430 and 409 for definitions.

The proper sizing of an overcurrent protection device is the responsibility of the customer and should be determined using the application standards of the NEC (National Electric Code), CEC (Canadian Electrical Code) or other applicable standards. Per fine print note of 2008 NEC

Section 100 "A current in excess of rating may be accommodated by certain equipment and conductors for a given set of conditions.

Therefore, the rules for overcurrent protection are specific for particular situations."

UL489

Branch Protection

UL1077

Supplementary Protection

What You Need to Know and Look For In Specifications Certifications – Standards – Acceptance

UL489

Branch Protection

UL1077

Supplementary Protection

• UL489 Listed or Recognized

• CSA C22.2 No. 5

• International ratings available depending on breaker type

• UL Recognized under UL1077

• CSA 22.2 No. 285

• IEC 60947-2 or IEC 898

Function

• Opens automatically on Overload and Short Circuit when properly applied with-in its ratings

• Protects wire and cable against Overload and Short Circuit

• Opens automatically on Overload and Short Circuit

• Provides additional equipment protection where branch circuit protection is already provided or not required

• Not suitable for the protection of branch circuit conductors Applications

• Branch circuit protection in control panels, panelboards, switchboards and motor control centers

• Motor overload and motor short circuit protection (UL489 Recognized motor circuit protectors) for control panels and motor control centers

• Used within appliances or other electrical equipment such as control circuits, control power transformers, relays, PLC I/O points and lighting circuits

• Ideal replacement for fuses that are applied as supplementary protection

Features

• Bolted down or DIN-rail mounted

• External handle mechanisms available

• Field mounted accessories

• Stand alone branch circuit protection

• Various levels of protection (curve type)

• High voltage and interruption levels (up to 100 kAIC @ 480V)

• DIN-Rail mounted

• Field mounted accessories

• Current limiting

• Various levels of protection (curve type)

• 10 kAIC @ 240 VAC

• 6 kAIC @ 277 VAC and 5 kAIC @ 480 VAC

• 10 kAIC @ 65 VDC kAIC = thousands of Amps interrupt capacity Summary

A Supplementary Protector can’t Be used for Branch Circuit Protection.

Understanding the difference between Branch Circuit Protection and Supplementary Protection helps to ensure their proper use.

Electrical Data Sheets - Item #01 - G3P-080Electrical Data Sheets - Item #01 - G3P-080

9-19-1

Circuit Protection 1 - 8 0 0 - 6 3 3 - 0 4 0 5e31–34 Volume 14

3P Series Molded Case Circuit Breakers Overview

Overview Designed to provide branch and feeder circuit protection in industrial control panels, this line of Molded Case Circuit Breakers supplies protection against overload in conductors and short circuit in connected equipment such as motors.

They are UL listed for installation in UL 508 control panels. Their small size, in relation to standard circuit breakers or other comparable devices, saves panel space. Four frame sizes and all standard accessories are available.

Listings

• UL 489MCCB, File: E7819

• Field-installed accessories:

UL file E64983

• CSA 22.2 No.5, File: 43556

• IEC 157-1

• NEMA Standards Pub. No. AB1-1993

Features

• UL489 listed performance for branch circuit overcurrent protection and disconnectingmeans

• Patented contact conductor designs featuring high-speed “blow-open” action, providing superior performance when high level fault currents produce extra-ordinary electromechanical forces

• Advanced arc extinguishing technology

• Toggle handle provides three positions (on/off/tripped) alongwith visual indicators

• Manufactured in ISO 9000 certified facilities

• HACR (heating, air conditioning and refrigeration) rated

• G-Frame and F-Frame breakers are suitable for reverse feed

• K-Frame and L-Frame breakers include 3-pole adjustablemagnetic trip.

G 3P - 020 - AUX

Molded Case Circuit Breaker Series (by frame size) G: 15 to 100 Amp F: 60 to 225 Amp K: 250 to 400 Amp L: 400 to 600 Amp

Accessory Description Code AUX: auxiliary contact UVAC: undervoltage release STAC: shunt trip AC STDC: shunt trip DC

Amp Rating

3 Pole

UVDC: undervoltage release

Molded Case Circuit Breakers Part Numbering System

Molded Case Circuit Breakers Technical Specifications

Circuit Breaker Type

Ampere Rating at 40°C

No.

Poles

Volts Type of

Trip*

Federal Specification W-C-375b

UL 489 Interrupting Ratings (rms Symmetrical Amperes) (kA)

AC DC

Volts AC (50/60 Hz) Volts DC

240 480 600 250** G-Frame 15 -100 3 480 250 N.I.T.U 13b 65 22 – 10

F-Frame 60 - 225 3 600 250 N.I.T.U 22a 65 35 18 10

K-Frame 250 - 400 3 600 250 I.T.U 23a 65 35 25 10

L-Frame 400 - 600 3 600 250 I.T.U 23a 65 35 25 22

*Note: N.I.T.U denotes non-interchangeable trip unit. I.T.U denotes interchangeable trip unit.

**Note: For DC or 1-phase AC applications, use the two outside poles of the 3-pole circuit breaker

Manufactured by Eaton Corporation

Note: These parts available for sale to North American locations only.

9-29-2

Circuit Protectionw w w . a u t o m a t i o n d i r e c t . c o m / c i r c u i t - p r o t e c t i o n e31–35

Information

Systems Overview

Programmable Controllers

Field I/O

Software

C-more & other HMI

Drives

Soft Starters

Motors & Gearbox

Steppers/ Servos

Motor Controls

Proximity Sensors

Photo Sensors

Limit Switches

Encoders

Current Sensors

Pressure Sensors

Temperature Sensors

Pushbuttons/ Lights

Process

Relays/ Timers

Comm.

Terminal Blocks & Wiring

Power

Circuit Protection

Enclosures

Tools

Pneumatics

Safety

Appendix

Product Index

Part # Index

Volume 14

G-Frame Accessory Selection Guide Part Number Price Description GHMVD06B <---> NEMA 1/12 rotary handle for G-Frame. Position indicating; lock-off feature. Shaft length: 6”

GHMVD12B <---> NEMA 1/12 rotary handle for G-Frame. Position indicating; lock-off feature. Shaft length: 12”

F0S03C <---> NEMA 1/12 flexible shaft handle for G-Frame. Flange mounted. Lockable. Shaft length: 3’

F0S06C <---> NEMA 1/12 flexible shaft handle for G-Frame. Flange mounted. Lockable. Shaft length: 6’

3TA100G6K <---> Multi-wire connector to allow 6 wires to be connected to the G-frame. UL for copper only. 14-6AWG. Package of 3

GDIN <---> DIN rail clip adapter to allow mounting of G-Frame unit on 35mm DIN rail. Pkg of 1 includes mounting hardware.

3P Series Molded Case Circuit Breakers 15 - 100 Amp G-Frame

G-Frame Series Three Pole Molded Case Circuit Breakers

Part Number Price Description Pre-Installed Accessories* Ampere Rating Voltage InterruptCapacity

G3P-015 <---> Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.

None

240VAC

480VAC

250VDC**

65kA 22kA 10kA

G3P-015-AUX <---> With auxiliary contact, SPDT

G3P-020 <---> Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.

None

G3P-020-AUX <---> With auxiliary contact, SPDT

G3P-025 <---> Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.

None 25

G3P-030 <---> None

G3P-030-AUX <--->

Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.

With auxiliary contact, SPDT

G3P-030-STAC <---> With 120 VAC shunt trip

G3P-030-STDC <---> With 24 VDC shunt trip

G3P-030-UVAC <---> With 120 VAC undervoltage release

G3P-040 <---> Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.

None 40

G3P-050 <---> None 50

G3P-060 <---> None

G3P-060-AUX <--->

Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.

With auxiliary contact, SPDT

G3P-060-STAC <---> With 120 VAC shunt trip

G3P-060-STDC <---> With 24 VDC shunt trip

G3P-060-UVAC <---> With 120 VAC undervoltage release

G3P-070 <---> Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.

None 70

G3P-080 <---> None 80

G3P-090 <---> None 90

G3P-100 <--->

Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.

None

G3P-100-AUX <---> With auxiliary contact, SPDT

G3P-100-STAC <---> With 120 VAC shunt trip

G3P-100-STDC <---> With 24 VDC shunt trip

G3P-100-UVAC <---> With 120 VAC undervoltage release

*Note: Available accessories are pre-installed on G-Frame and F-Frame Molded Case Circuit Breakers. They are not field installable or interchangeable.

** For DC or 1-phase AC applications, use the two outside poles of the 3-pole circuit breaker

G-Frame circuit breakers are available as a single unit, or with accessories pre-installed only. Accessories are not field installable on this frame size. G-Frame breakers are suitable for reverse feed use. All breakers include base mounting hardware for panel mount applications.

G3P-40

GHMVD12B

GDIN

F0S03C

3TA100G6K

AWG Wire Range Specifications Circuit Breaker

Ampere Rating

Wire Type

AWG Wire Range

Metric Wire Range mm2

G-Frame 15 - 20

Cu/AI 14 - 10 2.5 - 4

25 - 100 10 - 1/0 4 - 50

G-Frame Electrical Ratings

Volts Frequency Amperes ContactArrangement G-Frame Auxiliary Switch 240 VAC 50/60 Hz 6 1a/1b - SPDT

G-Frame Shunt Trip 120 VAC 50/60 Hz 1.1

24 VDC DC 5.7

G-Frame Undervoltage Release Mechanism

120 VAC 50/60 Hz 0.05

Dropout Voltage Pickup Voltage Min Max Max

38.5 VAC 77.0 VAC 93.5 VAC

Electrical Data Sheets - Item #01 - G3P-080Electrical Data Sheets - Item #01 - G3P-080

9-39-3 http://www.automationdirect.com/pn/G3P-030-STAC http://www.automationdirect.com/pn/G3P-030-STDC http://www.automationdirect.com/pn/G3P-030-UVAC http://www.automationdirect.com/pn/G3P-060-STAC http://www.automationdirect.com/pn/G3P-060-STDC http://www.automationdirect.com/pn/G3P-060-UVAC http://www.automationdirect.com/pn/G3P-100-STAC http://www.automationdirect.com/pn/G3P-100-STDC http://www.automationdirect.com/pn/G3P-100-UVAC http://www.automationdirect.com/pn/G3P-015-AUX http://www.automationdirect.com/pn/G3P-020-AUX http://www.automationdirect.com/pn/G3P-030-AUX http://www.automationdirect.com/pn/G3P-060-AUX http://www.automationdirect.com/pn/G3P-100-AUX http://www.automationdirect.com/pn/3TA100G6K http://www.automationdirect.com/pn/3TA100G6K http://www.automationdirect.com/pn/GHMVD06B http://www.automationdirect.com/pn/GHMVD12B http://www.automationdirect.com/pn/GHMVD12B http://www.automationdirect.com/pn/G3P-015 http://www.automationdirect.com/pn/G3P-020 http://www.automationdirect.com/pn/G3P-025 http://www.automationdirect.com/pn/G3P-030 http://www.automationdirect.com/pn/G3P-040 http://www.automationdirect.com/pn/G3P-050 http://www.automationdirect.com/pn/G3P-060 http://www.automationdirect.com/pn/G3P-070 http://www.automationdirect.com/pn/G3P-080 http://www.automationdirect.com/pn/G3P-090 http://www.automationdirect.com/pn/G3P-100 http://www.automationdirect.com/pn/F0S03C http://www.automationdirect.com/pn/F0S06C http://www.automationdirect.com/pn/F0S03C http://www.automationdirect.com/pn/GDIN

Circuit Protection 1 - 8 0 0 - 6 3 3 - 0 4 0 5e31–36

3P Series Molded Case Circuit Breakers 15 - 100 Amp G-Frame

M aximum

I n t e r r u p t i n g R a t i n g ( S e e T a b u l a t i o n A b o v e

M inimum

.5

.3

.2

.1

.05

.03

.02

.01

.005

.003

.002

.001

1,000

5,000

3,000

2,000

HO

UR

M

IN

U

TE

HO

UR

S

10,000

.5

.3

.2

.1

.05

.03

.02

.01

.005

.003

.002

.001

1,000

5,000

3,000

2,000

HO

UR

M

IN

U

TE

HO

UR

S

8060 907050 10

,0

0, ,0

,0

,0

,0

,0

,0

,0

,0

,0

8060 907050

0, ,0

,0

,0

,0

,0

,0

,0

,0

10,000

M ax im um Vo l ts

Type

G 3P

Con t inuous A mperes

15-60 70-100

G 3 P

500-1300 1300-1800

S y m m e t r i c a l R M S A m p e r e s 240 Volts

65,000

400-1100 700-1300

480 Volts 22,000

C U R R E N T I N P E R C E N T O F B R E A K E R T R I P U N I T R A T I N G

C i r c u i t B r e a k e r T i m e / C u r r e n t C u r v e s C a t a l o g T y p e G 3 P 1 5 - 1 0 0 A m p e r e s F o r a p p l i c a t i o n a n d c o o r d i n a t i o n p u r p o s e s o n l y . B a s e d o n 4 0 ˚ C a m b i e n t , c o l d s t a r t . C o n n e c t e d w i t h f o u r ( 4 ) f e e t o f r a t e d w i r e ( 6 0 / 7 5 ˚ C ) p e r t e r m i n a l . T e s t e d i n o p e n a i r w i t h c u r r e n t i n a l l p o l e s e x c e p t f o r i n s t a n t a n e o u s t r i p , s e e b e l o w

B r e a k e r

B r e a k e r I n s t a n t a n e o u s T r i p , A m p e r e s

A C V o l t s 6 0 H z

S i n g l e P o l e 2 P o l e s i n S e r i e s

I n t e r r u p t i n g R a t i n g ( U L L i s t e d ) B r e a k e r T y p e

I n s t a n t a n e o u s T r i p ( S e e T a b u l a t i o n a b o v e )

M a x i m u m I n t e r r u p t i n g T i m e

C U R R E N T I N P E R C E N T O F B R E A K E R T R I P U N I T R A T I N G

T

IM

E

IN

S E

C O

N D

S T

IM

E

IN

S

E C

O N

D S

9-49-4

Circuit Protection 1 - 8 0 0 - 6 3 3 - 0 4 0 5e31–50

3P Series Molded Case Circuit Breakers – Dimensions

4.875 (123.83)

2.625 (66.65)

.348 (8.83) Dia., 6 Holes in Cover.141 (3.57) Dia. 4 Holes

.281 (7.14) Dia C'Bores

.18 (4.57) Deep For Mounting Purposes

3.000 (76.17)

7̊

OFF

Front View Side View

On Off

.450 (11.43) diameter 6 holes

.110(2.8) dia.

x .310(7.9) deep, 2 holes accept #6 (M3.5) thread cutting screws

Push to Trip

6.000 (152.40)

3.375 (85.73)

.197(5.00) diameter hole

.328(8.33) diameter c'bore 1.938(49.23) deep from top.

.344(8.74) diameter c'bore .656(16.66) deep from bottom.

4 mounting holes for .164-32 (No. 8) x 1.500( M4 x0.7x 38.10) mounting screws.

4.13(105.0)

Side ViewFront View

60 - 225 Amp F-Frame

15 - 100 Amp G-Frame inches(mm) inches(mm)

9-59-5

Circuit Protection 1 - 8 0 0 - 6 3 3 - 0 4 0 5e31–52

Rotary Handle Accessory Selection Guide Part Number Price Description GHMVD06B <---> NEMA 1/12 black rotary handle for G-Frame MCCB. Shaft length: 6” GHMVD12B <---> NEMA 1/12 black rotary handle for G-Frame MCCB. Shaft length: 12” FHMVD12B <---> NEMA 1/12 black rotary handle for F-Frame MCCB. Shaft length: 12” HM1R12X <---> NEMA 4/4X black rotary handle for F-Frame MCCB. Shaft length: 12” HM1R24X <---> NEMA 4/4X black rotary handle for F-Frame MCCB. Shaft length: 24”

KHMVD12B <---> NEMA 1/12 black rotary handle for K-Frame MCCB. Shaft length: 12” HM3R12X <---> NEMA 4/4X black rotary handle for K-Frame MCCB. Shaft length: 12” HM3R24X <---> NEMA 4/4X black rotary handle for K-Frame MCCB. Shaft length: 24” LHMVD12B <---> NEMA 1/12 black rotary handle for L-Frame MCCB. Shaft length: 12” HM4R12X <---> NEMA 4/4X black rotary handle for K-Frame MCCB. Shaft length: 12” HM4R24X <---> NEMA 4/4X black rotary handle for K-Frame MCCB. Shaft length: 24”

Rotary Handle

Flex Shaft™ Flexible Handle

A universal rotary handle is available for each frame size of molded case circuit breaker. The handles are suitable for use with NEMA 1, 12, 4 or 4x enclosures. Features include:

• Large handle easily accommodates gloves

• Global ON/OFF markings (I/ON, O/OFF) and TRIP indication on handle

• Access Handle Lock-Off by pressing arrow on handle insert

• Door interlock and defeater

• Metal shaft and base

• Pipe valve operation (ON=Vertical, OFF=Horizontal) with 90 degree rotation

• UL 489, IEC 947-1/-2, CSA

Meeting crucial time limits for shutdown procedures is easier with an externally mounted handle. The flexible handle makes it possible to operate the circuit breaker externally, and can be used in enclosures of varying depths and heights. It can be used with NEMA 1, NEMA 3R and NEMA 12 enclosures, and accepts up to three padlock shackles.

Note: A minimum bending radius of four inches is necessary for proper operation.

GHMVD12B

HM1R12X

F0S03C

Flexible Handle Accessory Selection Guide Part Number Price Description

F0S03C <---> NEMA 1/12 flexible shaft handle for G-Frame MCCB. Shaft length: 3’ F0S06C <---> NEMA 1/12 flexible shaft handle for G-Frame MCCB. Shaft length: 6’ F1S03C <---> NEMA 1/12 flexible shaft handle for F-Frame MCCB. Shaft length: 3’ F1S06C <---> NEMA 1/12 flexible shaft handle for F-Frame MCCB. Shaft length: 6’ F3S03C <---> NEMA 1/12 flexible shaft handle for K-Frame MCCB. Shaft length: 3’ F3S06C <---> NEMA 1/12 flexible shaft handle for K-Frame MCCB. Shaft length: 6’ F4S04C <---> NEMA 1/12 flexible shaft handle for L-Frame MCCB. Shaft length: 4’ F4S06C <---> NEMA 1/12 flexible shaft handle for L-Frame MCCB. Shaft length: 6’

3P Series Molded Case Circuit Breakers – Accessories Field Mountable Accessories

Electrical Data Sheets - Item #01 - G3P-080Electrical Data Sheets - Item #01 - G3P-080

9-69-6 http://www.automationdirect.com/pn/GHMVD06B http://www.automationdirect.com/pn/GHMVD12B http://www.automationdirect.com/pn/FHMVD12B http://www.automationdirect.com/pn/KHMVD12B http://www.automationdirect.com/pn/LHMVD12B http://www.automationdirect.com/pn/GHMVD12B http://www.automationdirect.com/pn/HM1R12X http://www.automationdirect.com/pn/HM1R24X http://www.automationdirect.com/pn/HM3R12X http://www.automationdirect.com/pn/HM3R24X http://www.automationdirect.com/pn/HM4R12X http://www.automationdirect.com/pn/HM4R24X http://www.automationdirect.com/pn/HM1R12X http://www.automationdirect.com/pn/F0S03C http://www.automationdirect.com/pn/F0S03C http://www.automationdirect.com/pn/F0S06C http://www.automationdirect.com/pn/F1S03C http://www.automationdirect.com/pn/F1S06C http://www.automationdirect.com/pn/F3S03C http://www.automationdirect.com/pn/F3S06C http://www.automationdirect.com/pn/F4S04C http://www.automationdirect.com/pn/F4S06C

Circuit Protectionw w w . a u t o m a t i o n d i r e c t . c o m / c i r c u i t - p r o t e c t i o n e31–53

Information

Systems Overview

Programmable Controllers

Field I/O

Software

C-more & other HMI

Drives

Soft Starters

Motors & Gearbox

Steppers/ Servos

Motor Controls

Proximity Sensors

Photo Sensors

Limit Switches

Encoders

Current Sensors

Pressure Sensors

Temperature Sensors

Pushbuttons/ Lights

Process

Relays/ Timers

Comm.

Terminal Blocks & Wiring

Power

Circuit Protection

Enclosures

Tools

Pneumatics

Safety

Appendix

Product Index

Part # Index

Volume 14

Undervoltage Release Accessory Selection Guide Part Number Price Description UVH3LP08K <---> Field installable 110 - 127 VAC undervoltage release for K-Frame MCCB UVH4LP08K <---> Field installable 110 - 127 VAC undervoltage release for L-Frame MCCB UVH3LP21K <---> Field installable 24 VDC undervoltage release for K-Frame MCCB UVH4LP21K <---> Field installable 24 VDC undervoltage release for L-Frame MCCB

Undervoltage Release

This product monitors a voltage (typically a line voltage) and trips the circuit breaker when the voltage falls to between 70% and 35% of the solenoid coil rating. It consists of a continuous rated solenoid, with a plunger and tripping lever mounted in a plug-in module.

Note: The undervoltage release is a pre-installed accessory on G-Frame and F-Frame breakers.

UVH3LP21K

3P Series Molded Case Circuit Breakers – Accessories

Auxiliary Contact Accessory Selection Guide Part Number Price Description

A1X3PK <---> Field installable auxiliary contact for K-Frame MCCB, SPDT, 18” pigtail leads

A1X4PK <---> Field installable auxiliary contact for L-Frame MCCB, SPDT, 18” pigtail leads

Field Mountable Accessories Auxiliary Contact The auxiliary contact provides circuit breaker contact status information by monitoring the position of the molded cross bar which contains the moving contact arms. The auxiliary switch is used for remote indication and interlock system verification, and consists of one SPDT switch housed in a plug-in module. Each SPDT switch has one ‘a’ and one ‘b’ contact. When the circuit breaker contacts are open, the ‘a’ contact is open and the ‘b’ contact is closed.

Note: Field installable auxiliary contacts are not available for the G and F frame breakers.

For G and F frame auxiliary contacts, order breakers with -AUX as part of the part number.

Please see G and F-frame sections for available selections.

A1X3PK

K-Frame Undervoltage Release Mechanism

Supply Voltage

Dropout Voltage

Pickup Voltage VA Notes

Min Max Max 24 VDC 8.4 16.8 20.4 3.1 1. Endurance:

5000 electrical operations plus 1000 mechani-cal operatons.

2. 50/60 Hz

110 VAC2

44.5 77.0 93.5 1.8

120 VAC2 2.1

127 VAC2 2.4

L-Frame Undervoltage Release Mechanism

Supply Voltage

Dropout Voltage

Pickup Voltage VA

Notes Min Max Max

24 VDC 8.4 16.8 20.4 3.1 1. Endurance:

5000 electrical operations plus 1000 mechani-cal operatons.

2. 50/60 Hz

110 VAC2

44.5 77.0 93.5 1.8

120 VAC2 2.1

127 VAC2 2.4

K-Frame Electrical Ratings 1,2

Max Volts Frequency Max

Amperes Dielectric Withstand Voltage

Notes

K-Frame Auxiliary Switch

600 50/60 Hz 6

1. Endurance: 5000 electri-cal operations plus 1000 mechanical operatons.

2. Pigtail wire size: 18 AWG (0.82 mm2)

3. Non-inductive load

125 DC 0.503

250 DC 0.253

L-Frame Electrical Ratings 1,2

Max Volts Frequency Max

Amperes Dielectric Withstand Voltage

Notes

L-Frame Auxiliary Switch

600 50/60 Hz 6

1. Endurance: 5000 electrical operations plus 1000 mechanical operatons.

2. Pigtail wire size: 18 AWG

(0.82 mm2)

3. Non-inductive load

125 DC 0.503

250 DC 0.253

Electrical Data Sheets - Item #01 - G3P-080Electrical Data Sheets - Item #01 - G3P-080

9-79-7 http://www.automationdirect.com/pn/UVH3LP08K http://www.automationdirect.com/pn/UVH4LP08K http://www.automationdirect.com/pn/UVH3LP21K http://www.automationdirect.com/pn/UVH4LP21K http://www.automationdirect.com/pn/UVH3LP21K http://www.automationdirect.com/pn/A1X3PK http://www.automationdirect.com/pn/A1X4PK http://www.automationdirect.com/pn/A1X3PK

Circuit Protection 1 - 8 0 0 - 6 3 3 - 0 4 0 5e31–54

3P Series Molded Case Circuit Breakers – Accessories

Shunt Trip Accessory Selection Guide Part Number Price Description SNT3P11K <---> Field installable 110/240 VAC / 110/125 VDC shunt trip for K-Frame MCCB.

SNT4RP11K <---> Field installable 110/240 VAC shunt trip for L-Frame MCCB SNT3P04K <---> Field installable 12/24 VAC/DC shunt trip for K-Frame MCCB SNT4RP03K <---> Field installable 12/24 VAC/DC shunt trip for L-Frame MCCB

Shunt Trip The Shunt Trip provides remote controlled tripping of the circuit breaker. Consisting of an intermittent rated solenoid with a tripping plunger and a cutoff switch assembled to a plug-in module, shunt trip coils are designed to be applied at specific AC or DC volt-ages.

SNT3P04K

Field Mountable Accessories

L-Frame Shunt Trip

Supply Voltage

Min Operating Voltage

VA Supply Voltage

Min Operating Voltage

VA Notes

VVAACC 5500//6600 HHzz VVDDCC

1. Endurance: 5000 electrical operations plus 1000 mechanical operatons.

2. Approx. unlatching time: 6 ms Approx. total circuit breaker contact opening time: 18 ms

45 12

24 200 24 170

100 – – – 120 120 – – – 127 140 – – – 208 420 – – – 220 470 – – – 240 550 – – –

K-Frame Shunt Trip

Supply Voltage

Min Operating Voltage

VA Supply Voltage

Min Operating Voltage

VA Notes

VVAACC 5500//6600 HHzz VVDDCC

1. Endurance: 5000 electrical operations plus 1000 mechani-cal operatons.

2. Approx. unlatching time: 6 ms Approx. total circuit breaker contact opening time: 8 ms

45 12 8.4

24 200 24 170

100 110 77 110 120 120 120 77 130 127 140 125 77 140 208 420 – – – 220 470 – – – 240 550 – – –

Electrical Data Sheets - Item #01 - G3P-080Electrical Data Sheets - Item #01 - G3P-080

9-89-8 http://www.automationdirect.com/pn/SNT4RP11K http://www.automationdirect.com/pn/SNT4RP03K http://www.automationdirect.com/pn/SNT3P11K http://www.automationdirect.com/pn/SNT3P04K http://www.automationdirect.com/pn/SNT3P04K

Circuit Protectionw w w . a u t o m a t i o n d i r e c t . c o m / c i r c u i t - p r o t e c t i o n e31–55

Information

Systems Overview

Programmable Controllers

Field I/O

Software

C-more & other HMI

Drives

Soft Starters

Motors & Gearbox

Steppers/ Servos

Motor Controls

Proximity Sensors

Photo Sensors

Limit Switches

Encoders

Current Sensors

Pressure Sensors

Temperature Sensors

Pushbuttons/ Lights

Process

Relays/ Timers

Comm.

Terminal Blocks & Wiring

Power

Circuit Protection

Enclosures

Tools

Pneumatics

Safety

Appendix

Product Index

Part # Index

Volume 14

Six-wire Connector Accessory Selection Guide Part Number Price Description 3TA100G6K <---> For G-Frame MCCBs. Pkg. of 3. Wire size: 14 - 6 AWG, copper 3TA150F6K <---> For F-Frame MCCBs. Pkg. of 3. Wire size: 14 - 6 AWG, copper

Six-wire Connector

Replacement Lug Kit Accessory Selection Guide Part Number Price Description 3TA225FD <---> Replacement lug kit for F-Frame MCCB. Package of (3) terminals.

3TA401K <---> Replacement lug kit for K-Frame MCCB. 3-pole kit (one terminal per pole and one ter-minal cover).

3TA603LDK <---> Replacement lug kit for L-Frame MCCB. 3-pole kit (one terminal per pole and one ter-minal cover). Wire range 400-500 AWG (185-240 m²), 2 conductors.

Safety Door Hardware Selection Guide Part Number Price Description

C361KJ4 <--->

Handle length: 4”. Mounting hardware included for enclosures up to 40” tall. For taller enclosures that require a 3-point latch, the C361KR (purchase separately) will also be needed.

C361KJ6 <--->

Handle length: 6”. Mounting hardware included for enclosures up to 40” tall. For taller enclosures that require a 3-point latch, the C361KR (purchase separately) will also be needed.

C361KR <--->

Door Interlocking safety roller kit for use with the C361KJ4 and C361KJ6 safety handle kits when the SDN12 series enclosure is taller than 40 inches and 3-point latching is required. Kit includes roller and all hardware.

Din Rail Mount Clip Accessory Selection Guide Part Number Price Description

GDIN <---> Clip for mounting G-Frame to 35 mm Din rail. Mounting hardware included. Pkg of 1

Replacement Lug Kit

Din Rail Mounting Clip

NEMA 12 Safety Door Hardware

This is a field installable multi-wire connector which allows six wires to be connected to the load side (OFF) end terminals. It is used to distribute the load from the circuit breaker to multiple devices without the use of separate distribution terminal blocks. UL listed for copper only as used on the load side (OFF) end. Includes mounting hardware, insulators and tin-plated aluminum connectors.

Save valuable panel space and wiring time by eliminating terminal blocks. Multi-wire lug kit includes mounting hardware, insulators and tin-plated aluminum connectors to replace three mechanical load lugs. UL listed for copper only as used on the load side (OFF) end.

3TA100G6K

3TA401K

GDIN

Safety Handle shown on enclosure

3P Series Molded Case Circuit Breakers – Accessories Field Mountable Accessories

Type C361 door interlocking safety handle kits are designed for use with AutomationDirect 3P series MCCBs and flexible handle, when mounted in an SDN12, or equivalent, enclosure. These handles secure the SDN12 enclosure, protecting against unauthorized entry while the MCCB is in the ON position. Use them on enclosures with right side flanges only and material thickness from 16 gauge through 3/16”. All mounting hardware is included for enclosures up to 40” tall. The addition of the C361KR roller kit is necessary for enclosures taller than 40” that require a 3-point latch. See SDN12 Enclosures section for enclosure specifications

Release Screw

Handle in OFF position

Note: The 1/4” x 1/2” standard mill rectangular locking bar is not supplied with these kits. The bar is supplied with the enclosures.

Electrical Data Sheets - Item #01 - G3P-080Electrical Data Sheets - Item #01 - G3P-080

9-99-9 http://www.automationdirect.com/pn/3TA100G6K http://www.automationdirect.com/pn/3TA150F6K http://www.automationdirect.com/pn/3TA603LDK http://www.automationdirect.com/pn/3TA100G6K http://www.automationdirect.com/pn/3TA225FD http://www.automationdirect.com/pn/3TA401K http://www.automationdirect.com/pn/C361KJ4 http://www.automationdirect.com/pn/C361KJ6 http://www.automationdirect.com/pn/C361KJ4 http://www.automationdirect.com/pn/C361KJ6 http://www.automationdirect.com/pn/3TA401K http://www.automationdirect.com/pn/C361KR http://www.automationdirect.com/pn/C361KR http://www.automationdirect.com/pn/C361KR http://www.automationdirect.com/pn/C361KR

Part Number:

Approvals

Current Rating

Voltage Rating

SCCR

No. of Inputs Wire Range Torque

ScrewType No. of Outputs

Wire Range Torque Wire Range Torque

ScrewType Optional MarkingTag **(for DB16 and DB35)

Dimensions:

DB16*

80A 80A

600V AC 690V AC

10kA

1 1 8-4 AWG 6-16mm2

13.5lb.-in. 1.5Nm

Pozi Drive 2 6 6

(2x)8-4 AWG (2x)6-16mm2

13.5lb.-in. 1.5Nm (4x)14-10 AWG (4x)2.5-6mm2

7.2lb.-in. 0.8Nm Pozi Drive 2

MT2**

38049

80A 80A

600V AC 690V AC

100kA

1 1 8-4 AWG 6-16mm2

13.5lb.-in. 1.5Nm

Pozi Drive 2 6 6

(2x)8-4 AWG (2x)6-16mm2

13.5lb.-in. 1.5Nm (4x)14-10 AWG (4x)2.5-6mm2

7.2lb.-in. 0.8Nm Pozi Drive 2

DB35*

115A 125A

600V AC 690V AC

10kA

1 1 8-2 AWG 10-35mm2

31lb.-in. 3.5Nm

Pozi Drive 2 6 6

14-6 AWG 2.5-16mm2

17.5lb.-in. 2Nm

Pozi Drive 2

MT2**

38041

115A 125A

600V AC 690V AC

100kA

1 1 8-2 AWG 10-35mm2

13.5lb.-in. 3.5Nm

Pozi Drive 2 6 6

14-6 AWG 2.5-16mm2

17.5lb.-in. 2Nm

Pozi Drive 2

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com32

DB16• Quick mounting and wiring

• IP20 Finger Safe

• DIN Rail or Panel Mount

• Blocks fit with other DIN Rail mountable modular devices (height 95mm, depth 44.5mm)

• Accessories increase the number of outputs with only one input (applies only to 38041 and 38032)

• No caps to open / remove

• Material

Housing: Polyamide Metal Body: Brass

Fork Type Busbar 38045

38041

UL File E220514 UL File E98082 UL File E220514 UL File E98082

Accessories: ForkType Busbar Part No: 38045 to jump 2 Blocks

38046 to jump 8 Blocks can be cut

38041

38049 DB35 38041

One Phase Power Distribution Block

* Available in colors. Color Ordering Suffix Red R Blue BU Black BL Orange O Green G Yellow Y White W Beige BG Dark Brown DB

COLOR BLOCKS

(other than grey standard)

When ordering please add color suffix to Cat. No.

Example: CTS2.5U-N/R

Electrical Data Sheets - Item #02 - 38073Electrical Data Sheets - Item #02 - 38073

9-109-10

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 33

43 mm (1.69 in)

38.5 mm (1.52 in)

45 mm (1.77 in) m m (2

.2 in

5.2 mm (0.20 in)

17.4 mm (0.69 in)

13.8 mm (0.54 in)

19.9 mm (0.78 in)

5.2 mm (0.20 in) m m (2

.8 in

43 mm (1.69 in)

38.5 mm (1.52 in)

45 mm (1.77 in) m m (2

.2 in

5.2 mm (0.20 in)

17.4 mm (0.69 in)

13.8 mm (0.54 in)

19.9 mm (0.78 in)

5.2 mm (0.20 in) m m (2

.8 in

38032

38032

160A 160A

600V AC 690V AC

100kA

1 1 8-2/0AWG 10-70mm2

35.5lb.-in. 4Nm Hex 5

6 6 14-6 AWG 2.5-16mm2

17.5lb.-in. 2Nm Hex 3

38076

Part Number:

Approvals

Current Rating

Voltage Rating

SCCR

No. of Inputs Wire Range Torque

ScrewType No. of Outputs

Wire Range Torque

ScrewType

Dimensions:

38076

115A 125A

600V AC 690V AC

100kA

1 1 8-2 AWG 10-35mm2

53lb.-in. 6Nm Hex 4

10 10 14-4 AWG 2.5-16mm2

26.5lb.-in. 3Nm Hex 3

38074

38074

175A 175A

600V AC 690V AC

100kA

1 1 6-2/0AWG 16-70mm2

53lb.-in. 6Nm Hex 5

10 10 14-4 AWG 2.5-16mm2

26.5lb.-in. 3Nm Hex 3

Copper Jumper Bar 3803221

38032

UL File E98082 UL File E98082 UL File E98082

Accessories: Copper Jumper Bar (6x15 mm)

Part No: 3803221 for 2 Blocks 3803231 for 3 Blocks 3803241 for 4 Blocks can be cut

38032

One Phase Power Distribution BlockElectrical Data Sheets - Item #02 - 38073Electrical Data Sheets - Item #02 - 38073

9-119-11

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com34

38020 38019

Part Number:

Approvals

Current Rating

Voltage Rating

SCCR

No. of Inputs Wire Range Torque

ScrewType No. of Outputs

Wire Range Torque Wire Range Torque Wire Range Torque

ScrewType

Dimensions:

38020 38019

230A 250A 310A 400A

600V AC 690V AC 600V AC 690V AC

100kA 100kA

1 1 1 1 2-4/0AWG 35-120mm2 3/0-350mcm 95-185mm2

170lb.-in. 19Nm 230lb.-in. 25Nm Hex 6 Hex 8

11 11 11 11 (2x) 14-2AWG (2x) 2.5-35mm2 (2x) 14-2AWG (2x) 2.5-35mm2

31lb.-in. 3.5Nm 31lb.-in. 3.5Nm (5x) 14-6AWG (5x) 2.5-16mm2 (5x) 14-6AWG (5x) 2.5-16mm2

17.5lb.-in. 2Nm 17.5lb.-in. 2Nm (4x) 14-8AWG (4x) 2.5-10mm2 (4x) 14-8AWG (4x) 2.5-10mm2

17.5lb.-in. 2Nm 17.5lb.-in. 2Nm standard screwdriver standard screwdriver

UL File E98082 UL File E98082

• Quick mounting and wiring

• IP20 Finger Safe

• DIN Rail or Panel Mount

• Blocks fit with other DIN Rail mountable modular devices (height 95mm, depth 44.5mm)

• Accessories increase the number of outputs with only one input.

• No caps to open or remove

• Material

Housing: Polyamide Metal Body: Brass

One Phase Power Distribution BlockElectrical Data Sheets - Item #02 - 38073Electrical Data Sheets - Item #02 - 38073

9-129-12

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 35

38075 38073

Part Number:

Approvals

Current Rating

Voltage Rating

SCCR

No. of Inputs Wire Range Torque

ScrewType No. of Outputs

Wire Range Torque

ScrewType

Dimensions:

38075 38073

115A 115A 175A 175A

600V AC 690V AC 600V AC 690V AC

100kA 100kA

3x1 3x1 3x1 3x1 8-2AWG 10-35mm2 8-2/0AWG 10-70mm2

31lb.-in. 3.5Nm 35.5lb.-in. 4Nm Hex 4 Hex 5

3x6 3x6 3x6 3x6 14-4AWG 2.5-16mm2 14-4AWG 2.5-16mm2

17.5lb.-in. 2Nm 17.5 lb.-in. 2Nm Hex 3 Hex 3

3 Pole 3 Pole

• Quick mounting and wiring

• IP20 Finger Safe

• DIN Rail or Panel Mount

• Blocks fit with other DIN Rail mountable modular devices

• Same compact size for both ratings

• No caps to open or remove

• Material

Housing: Polyamide Metal Body: Brass

UL File E98082 UL File E98082

Three Phase Power Distribution BlockElectrical Data Sheets - Item #02 - 38073Electrical Data Sheets - Item #02 - 38073

9-139-13

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com36

• Quick mounting and wiring

• IP20 Finger Safe

• DIN Rail or Panel Mount

• No caps to open or remove

• Material

Housing: Polyamide Metal Body: Aluminum

38064 38057

Part Number:

Approvals

Current Rating

Voltage Rating

No. of Inputs Wire Range Torque

ScrewType No. of Outputs

Wire Range Torque

ScrewType

Dimensions:

38064

175A 175A

600V AC 690V AC

1 1 14-1AWG 2.5mm2-50mm2

106.2lb.-in. 12Nm Hex 5

1 1 14-1AWG 2.5mm2-50mm2

106.2lb.-in. 12Nm Hex 5

38057

335A 400A

600V AC 690V AC

1 1 6AWG-400MCM 16mm2-185mm2

221lb.-in. 25Nm Hex 10

1 1 6AWG-400MCM 16mm2-185mm2

221lb.-in. 25Nm Hex 10

38059

840A 800A

600V AC 690V AC

2 2 3AWG-600MCM 25-300mm2

310lb.-in. 35Nm Hex 10

2 2 3AWG-600MCM 25-300mm2

310lb.-in. 35Nm Hex 10

.6 m m

(2 .3 in)

25.4 mm (1.0 in)

50 mm (1.97 in)

.3 m m

(2 .8 in)

.7 m m

(1 .3 in)

.2 m m

(1 .7 in)

39 mm [1.54 in]

7 mm [0.28 in]

5.

m m [5

.7 in

7.5 mm [0.30 in]

4.

m m [4

.9 in

12 mm [0.47 in]

7 mm [0.28 in]

80.5 mm [3.17 in]

53.5 mm [2.11 in] m m

[5 .7 in m m

[5 .0 in

72 mm [2.83 in]

80.5 mm [3.17 in]

38059

UL File E98082 UL File E98082 UL File E98082

Splicer Blocks Electrical Data Sheets - Item #02 - 38073Electrical Data Sheets - Item #02 - 38073

9-149-14

Motor Controlsw w w . a u t o m a t i o n d i r e c t . c o m / m o t o r - c o n t r o l s e17-5

Information

Systems Overview

Programmable Controllers

Field I/O

Software

C-more & other HMI

Drives

Soft Starters

Motors & Gearbox

Steppers/ Servos

Motor Controls

Proximity Sensors

Photo Sensors

Limit Switches

Encoders

Current Sensors

Pressure Sensors

Temperature Sensors

Pushbuttons/ Lights

Process

Relays/ Timers

Comm.

Terminal Blocks & Wiring

Power

Circuit Protection

Enclosures

Tools

Pneumatics

Safety

Appendix

Product Index

Part # Index

Features

• 5 to 100 hp at 480 VAC

• cULus and CSA approval, CEmark, meets JIS and IEC standards.

• Models SC-E02-xxx to SC-E4-xxx have 3-polemain circuits and come in three sizes with widths of 43mm, 54mm, and 67mm.

•Models SC-E1-xxx to SC-E7-xxx employ a box terminal structure; allowingwires to be connected directly to themain circuit.

• Has a finger-protection terminal structure that prevents the exposure of live parts.

• Models SC-E5-xxx to SC-E7-xxx use a SUPERMAGNETTM (AC-input/DC-output operation) for high operating reliability and requires no surge suppressor.

Small Size

• SC-E02-xxx to E05-xxx: 43mmwide

• SC-E1-xxx to E2S-xxx: 54mmwide

• SC-E3-xxx, E4-xxx: 67mmwide

• SC-E5-xxx: 88mmwide

Safety

• Terminals with finger-touch protection (DIN 57106/VDE 0106 Teil100)

Utility

• Box lug terminal construction

• Long electrical life

• Easy to wire

Environmental

• Low power consumption

• Recycled thermoplastic resin used for plastic parts.

• The names ofmaterials are indicated on all major parts to facilitate recycling

Standards & Approvals

• UL listed , file E42419, Standard UL 508

• cUL listed, file E42419, Standard CSA C 22.2 No.14

• VDE 0660

• JIS C 8201-4-1

• IEC 60947-4-1 / EN 60947-4-1

• CE compliant

Optional accessories

• Auxiliary contact blocks

• Coil surge suppression units

• Replacement coils for contactor sizes SC-E5 and larger

Fuji Duo Series SC-E Contactors

SC-E2S

SC-E Series Contactors Specifications - UL and CSA

Model Price

No m in al Co il

Vo lta ge

Rated Capacity (HP)

Ra te d

AC

-3

Cu rr en t( A)

[n ot e 1]

Ra te d

AC

-1

Th er m al Cu rr en t

(A no te

2]

SC

CR

Ra tin gs

(K A)

Ra te d In su la tio n

Vo lta ge

(V

Fr am e W id th

(m m

3-Phase Motor 1-Phase Motor

200V 220– 240V

440– 480V

550– 600V

100– 120V

220– 240V

SC-E02-24VAC <---> 24VAC

2 2 5 5 1/3 1 9 20

5 690 43

SC-E02-110VAC <---> 110VAC

SC-E02-220VAC <---> 220VAC

SC-E02-440VAC <---> 440-480VAC

SC-E02-500VAC <---> 500-550VAC

SC-E02G-24VDC <---> 24VDC

SC-E03-24VAC …

This is the start of the file's text. The full file is on GovTribe.