Electrical Snap action electrical switch recognized by Underwriters’ Laboratories, Inc. and CSA International
Electrical Connection ¹⁄₂ NPT female conduit connection with terminal block
Pressure Connection Wetted Material 1 ¹⁄₄ NPT Female
Temperature Range* Ambient: -40°F to +180°F
(-40°C to +82°C) Media: -40°F to +300°F
(-40°C to +149°C)
*Temperature limits change with O-Ring selection
Adjustment Concealed wrench flat adjustment with range scale
Shipping Weight Approximately 3 pounds
Neo-Dyn® Series 200P Pressure Switch/ Internal Adjustment
Operating Pressure Data
Standard Specifications Ordering Sequence — Select desired option for each category
DESCRIPTION
Versatile Nega-Rate® Belleville disc spring pressure switch for a wide range of applications. Series 200P (piston sensor) for hydraulic applications up to 10000 psig system pressure.
Weather Proof (NEMA 4 and 13)
When factory presetting is desired, stipulate set point, increasing or decreasing
Insert available option number or letter designation as required
Series Wetted Material Adjustable Range Electrical Form Enclosure Miscellaneous
200P
OPTIONS
Wetted Material 1 Aluminum port and piston, Teflon seal and Buna-N O-Ring Adjustable Range 2 14 psig dec. to 220 psig inc. (1.0 bar dec. to 15.2 bar inc.)
3 150 psig dec. to 1500 psig inc. (10.3 bar dec. to 103.4 bar inc.)
6 375 psig dec. to 3000 psig inc. (25.9 bar dec. to 206.9 bar inc.)
8 800 psig dec. to 10000 psig inc. (55.2 bar dec. to 689.5 bar inc.)
Electrical Form C 15 amp at 125 or 250 VAC; ¹⁄₈ hp at 125 VAC; ¹⁄₄ hp at 250 VAC;
.5 amp resistive, .04 amp inductive at 125 VDC CC 11 amp, ¹⁄₄ hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC;
.5 amp resistive at 125 VDC Z 15 amp at 125 or 250 VAC; ¹⁄₄ hp at 125 VAC; ¹⁄₂ hp at 250 VAC; 1 amp resistive, .5 amp inductive at 125 VDC Enclosure 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 Miscellaneous A Epoxy paint exterior — extra protection for severe environments B Viton O-Ring C EPR O-Ring E ⁷⁄₁₆" - 20 SAE port L Neon indicator light — 115 VAC M Gold electrical contacts for extremely low current applications P 5-Pin Brad Harrison connector (Reduce AC electrical rating to 8 amps)
— (Not for CC3 Electrical) W Stainless steel screws — exterior X UL and CSA Certified with CE Mark (Not available with L or P option) Special (Consult representative or factory)
Non-catalog adjustable range and/or set point, deadband and proof pressure Operating temperature capability from -65°F to +400°F Manual reset — decreasing only (available in C3 only) 10 amps 125 VDC electrical rating
Adjustable Range
Number
Deadband† (approximate) Maximum Recommended System Pressure
10000*
Proof Pressure
10000 10000
15000**
Adjustable Set Point Range
Increasing 20 to 220
200 to 1500 500 to 3000
1000 to 10000
Decreasing 14 to 202
150 to 1275 375 to 2700 800 to 9000
All values given in psig.
†The deadband increases as the adjustable set point is increased.
*Diminished safety factor equal to approximately 2:1.
**Diminished safety factor equal to approximately 1.3:1.
13 C 3 _
Ordering Procedure Example
Max.
Min.
HPU Item #32
Hydraulic Power Unit - Item #32Hydraulic Power Unit - Item #32
8-1028-102
7.0 Max.
3.6
.82
1.72
Conduit Connection
¹⁄₂ NPT
Pessure Port
¹⁄₄ NPT2.72
3.50
2.72
.37
3.50
.265 Dia.
Mtg. Holes (2 places)
1.18
2.85 Max.
1.12 .50
Snap Action Electrical Element
Terminal Strip
Adjustment
Actuator Minimum Bearing Points
Teflon and O-Ring Seal
Piston Pressure Port
Negative Rate Belleville Disc Spring
Series 200PField Adjustable 14 to 10000 psig
Envelope Dimensions
Electrical Form
Basic Principles of Design
28150 Industry Drive, Valencia, CA 91355 Tel: 661-295-4000 Fax: 661-294-1750
FORM "C"
(SPDT)
RED
BRN
BLU
NC1
INC
P
C1
NO1
GRN
SCREW
FORM "CC"
(DPDT)
RED
BRN
BLU
BLK
YEL
VIO
NC1
INC
P
C1
NO1
NC2
C2
NO2
GRN
SCREW
Form #109-rev.a
FORM "Z"
(DOUBLE BREAK)
BLKRED NC NC
BLU VIONO NO
INC
P
GRN
SCREW
HPU Item #32
Hydraulic Power Unit - Item #32Hydraulic Power Unit - Item #32
8-1038-103
50 For pricing info, call 1-888-WIKA-USA or visit www.wika.com
Panel Builder Gauge
All Stainless Steel Construction
Glycerine Filled Case
The Type 233.55 LBM is specifically designed and manufactured to exact panel builder requirements. With exclusive features, it is ideal when used for panel mount gauges in the oil and gas, refinery, petrochemical, and food & beverage industries.
Industrial Gauges Type 233.55
Datasheet: 233.55
Standard Features Nominal Case Size: 2½" (63 mm)
Case Material: 304 stainless steel with off-set vent plug
Front Flange: Stainless steel
Wetted Parts: 316 SS
Window Type & Material: Safety glass
Dial Material: White aluminum Liquid Fillable Gauge: Standard
Restrictor: Standard
Pointer Material/Type: Black aluminum
Accuracy: 2/1/2% of span ASME B40.100 Grade A
Connection Locations: LBM (lower back mount)
Media Operating Temperature: Max. 212°F
Ambient Operating Temperature: -4°F to 140°F (-20°C to 160°C) maximum;
-40°F to 140°F w/silicone case fill
Items without part numbers are available - consult factory.
Type 233.55
Datasheet 233.55
Size 2½"
Conn. Size ¼" NPT
Connection LBM/FF
Press. Scale PSI PSI/BAR1 PSI/KPA PSI/KG/CM2
30" Hg 4282811 4283078 4283337 4283591
30"-0-15 psi 4282829 4283086 4283345 4283604
30"-0-30 psi 4282837 4283094 4283354 4283613
30"-0-60 psi 4282845 4283107 4283362 4283621
30"-0-100 psi 4282854 4283115 4283370 4283639
30"-0-160 psi 4282862 4283124 4283388 4283647
30"-0-200 psi 4282870 4283133 4283396 4283655
15 psi 4282888 4283141 4283400 4283664
30 psi 4282896 4283159 4283418 4283672
60 psi 4282900 4283167 4283426 4283680
100 psi 4282918 4283175 4283434 4283698
160 psi 4282926 4283184 4283443 4283702
200 psi 4282934 4283192 4283451 4283710
300 psi 4282943 4283204 4283469 4283728
400 psi 4282951 4283214 4283477 4283736
600 psi 4282969 4283222 4283485 4283744
800 psi 4282977 4283230 4283494 4283753
1,000 psi 4282985 4283248 4283507 4283761
1,500 psi 4282994 4283256 4283515 4283779
2,000 psi 4283000 4283264 4283524 4283787
3,000 psi 4283018 4283273 4283532 4283795
5,000 psi 4283026 4283281 4283540 4283809
6,000 psi 4283034 4283299 4283558 4283817
10,000 psi 4283044 4283303 4283566 4283825
15,000 psi 4283052 4283311 4283574 4283834
20,000 psi 4283060 4283329 4283583 4283842
¹"PSI/BAR" denotes dual scale; PSI outside in black, BAR inside in red.
2"PSI/KG/CM²" denotes dual scale; PSI outside in black, KG/CM² inside in red.
Note: Vacuum scale: 30" Hg outside in black; 760 mm Hg inside in red.
Note: Stock items shown in bold, blue print.
Additional accessories available -see "Accessories" section in back of catalog
HPU Item #33-37Hydraulic Power Unit - Item #33-37Hydraulic Power Unit - Item #33-37
8-1048-104
STAUFF
STA
STA
Test hose with swivel nut
Protective cap
Test coupling
T8
Test 20 Type SKK Connection Thread M 16 x 2
T E
S T
The complete STAUFF-TEST-20-Type-SKK range is also available with hexagonal protection cap made of steel or plastic protection cap
Fast Coupling for:
• Monitoring and control of pressure
• Venting
• Sampling Fluids
Advantages:
• Coupling at system pressure level
• Connection is leakproof before piston valve is open
• Simple connection to measurement, control and switching devices
• Self locking metal protective cap
• Minimizes introduction of contamination to hydraulic systems
Working Pressure:
• Max. working pressure 9000 PSI (630 bar) For SKK type G, K and S the recommended working pressure of fitting manufacturer should be noted
• Connection under pressure up to 5800 PSI (400 bar) max.
Materials:
• Metal parts: Steel, Stainless Steel on request
• Seals:
Standard V = FPM-VITON Temperature range – 4˚F to +392˚F (– 20˚ C to + 200˚ C)
Optional P = NBR-BUNA Temperature range – 4˚F to +195˚F
| (– | 20˚ C to + 90˚ | C) | |||||
| E | = | EPDM | Ethylene | Propylene | (for | Brake | Fluid) |
Temperature range – 40˚F to +302˚F (– 40˚ C to + 150˚ C)
| • | Hose: Polyamide Temperature range –31˚F to +212˚F | ||
| (–35˚ | C to +100˚ C) |
Media:
| • | Suitable | for | hydraulic | oils | and | other | low | viscosity | mineral |
| based | fluids | (Check | compatibility | of | seal | material) |
• For use with other liquid or gaseous media please consult STAUFF for details
HPU Item #39Hydraulic Power Unit - Item #38 - SKK20-716 UNF VE C6FHydraulic Power Unit - Item #38 - SKK20-716 UNF VE C6F
8-1058-105
G d1 t 1 t 2
30°
0.
2.
d1
G
90° t 1 t 2 a d1
G
90° t 1 t 2 a
G
90° t 1 t 2
G d1
1, a t 1 t 2
12° d2
17 10
0.67" 0.4"
STAUFF
hM 16
Hex
G
T9
Test 20 Type SKK Connection Thread M 16 x 2
T E
S T
M8 x 1 SKK 20 – M8 x 1 – PA SKK 20 – M8 x 1 – VA O-Ring Type A
M10 x 1 SKK 20 – M10 x 1 – PA SKK 20 – M10 x 1 – VA O-Ring Type A
M12 x 1,5 SKK 20 – M12 x 1,5 – PC SKK 20 – M12 x 1,5 – VC O-Ring Type C
M14 x 1,5 SKK 20 – M14 x 1,5 – PB SKK 20 – M14 x 1,5 – VB Metal joint Type B
M16 x 1,5 SKK 20 – M16 x 1,5 – PB SKK 20 – M16 x 1,5 – VB Metal joint Type B
G 1/8 SKK 20 – G 1/8 – PC SKK 20 – G 1/8 – VC O-Ring Type C
G 1/4 SKK 20 – G 1/4 – PB SKK 20 – G 1/4 – VB Metal joint Type B
G 1/4 SKK 20 – G 1/4 – PC SKK 20 – G 1/4 – VC O-Ring Type C
G 3/8 SKK 20 – G 3/8 – PB SKK 20 – G 3/8 – VB Metal joint Type B
R 1/8 taper SKK 20 – R 1/8 K-PD SKK 20 – R 1/8 K-VD Taper Type D
R 1/4 taper SKK 20 – R 1/4 K-PD SKK 20 – R 1/4 K-VD Taper Type D
1/8 NPT SKK 20 – 1/8 NPT-PD SKK 20 – 1/8 NPT-VD Taper Type D
1/4 NPT SKK 20 – 1/4 NPT-PD SKK 20 – 1/4 NPT-VD Taper Type D
5/16 – 24 UNF SKK 20 – 5/16 UNF-PE SKK 20 – 5/16 UNF-VE O-Ring Type E
7/16 – 20 UNF SKK 20 – 7/16 UNF-PE SKK 20 – 7/16 UNF-VE O-Ring Type E
1/2 – 20 UNF SKK 20 – 1/2 UNF-PE SKK 20 – 1/2 UNF-VE O-Ring Type E
9/16 – 18 UNF SKK 20 – 9/16 UNF-PE SKK 20 – 9/16 UNF-VE O-Ring Type E
Thread h Hex Order No.
G Seal Type NBR (BUNA) FPM (VITON) (see below) (Standard)
Test Coupling with Protective Cap SKK
To order hexagonal protection cap, add “SK” to part number. To order Plastic Protection cap, add “KK” to part number.
Other port connections and seals on request.
Port Connections and Seals
Type A Type B Type C Type D Type E (ISO 6149)
G d1 d2 t1 t2 a G t1 t2 G d1 t1 t2 a G d1 t1 t2 a G d1 t1 t2
5/16 – 24 UNF
7/16 – 20 UNF
1/2 – 20 UNF
9/16 – 18 UNF
R 1/8 taper
R 1/4 taper
1/8 NPT
1/4 NPT
M12 x 1,5
G 1/8
G 1/4
M14 x 1,5
M16 x 1,5
G 1/4
G 3/8
M8 x 1
M10 x 1 mm
1.45
1.45
1.45
1.45
1.45
1.53
1.45
1.45
1.45
1.45
1.41
1.41
1.38
1.50
1.50
1.50
1.45 in
.67
.67
.67
.75
.87
.67
.75
.75
.87
.67
.67
.67
.67
.67
.67
.67
.75 mm in
0.37
9,5 + 0,1
11,5 + 0,1
0.45 mm in mm in
0.43
15,5
0.61
0.47
16,5
0.65 mm in
0.79
0.87
0.75
0.91 mm in mm in mm in
0.47
18,5
0.73
1,5
0.06
0.47
18,5
0.73
1,5
0.06
0.47
18,5
0.73
1,5
0.06
0.47
18,5
0.73
1,5
0.06 mm in
0.71
0.59
0.75 mm in mm in mm in mm in mm in
5,5
0.22
9,5
0.37 8,5
0.33
13,5
0.53 6,9
0.27
11,6
0.46
0.39
16,4
0.65
0.06
0.47
18,5
0.73
1,5
0.31
0.51
1,0
0.04
0.47
18,5
0.73
1,5
0.06 mm in
9,1
0.36 12,4
0.49
0.55 mm in mm in mm in
0.47
0.67
0.39
0.83
11,5
0.45
0.55
0.91
11,5
0.45
0.55 mm in
0.07
1,9
2,4
0.09 2,4
0.09 15,6
0.61
0.98
12,7
0.50
15,5
0.61
2,5
0.10 mm in
(Add C6F for Standard Finish)
HPU Item #39Hydraulic Power Unit - Item #38 - SKK20-716 UNF VE C6FHydraulic Power Unit - Item #38 - SKK20-716 UNF VE C6F
8-1068-106
SW17
Ød l 3 1.
1.
SW17
l 3
Ød
STAUFF STAUFF
STAUFF
SW17
SW2
ød
I 2
1.
STAUFF
SW 1
SW 2
SW17 h ød
T10
Test 20 Type SKK Connection Thread M 16 x 2
T E
S T
PN l2 l3 h SW 1 SW 2 Order No.*
Series PSI Pipe (Bar) Ød Type G Type K Type S
Test Coupling SKK (compression ring fittings acc. to DIN 2353) - Metric Tubing
* For ordering BUNA seals please replace “V” with “P”
* For EPDM seals replace “V” with “E”
Type G Test coupling complete with straight fitting
Type S Test coupling for compression ring assembly
Type K Test coupling for 24˚ cone fittings
15,5 0.61
15,5 0.61
16,5 0.65
17,5 0.69
0.83
19,5 0.77
20,5 0.81
0.98
1.18
1.22
14,5 0.57
16,5 0.65
16,5 0.65
17,5 0.69
19,5 0.77
0.71
0.94
1.02
1.18
1.34
0.79
0.79
0.87
0.87
0.98
1.10
1.18
1.26
1.65
1.77
0.79
0.79
0.87
0.87
0.87
1.10
1.18
1.42
1.61
1.89
1.93
1.93
1.93
1.97
2.05
2.09
2.17
57,5 2.26
2.36
64,5 2.54
1.93
1.93
1.93
1.93
50,5 1.99
2.05
2.17
57,5 2.26
2.36
64,5 2.54
0.94
0.94
0.94
1.06
1.18
1.26
1.42
1.61
1.81
2.17
0.94
0.94
0.94
0.94
1.06
1.18
1.42
1.61
1.81
2.17
0.55
0.67
0.75
0.87
1.06
1.26
1.42
1.61
1.97
2.36
0.67
0.75
0.87
0.94
1.06
1.18
1.42
1.81
1.97
2.36 mm in mm in mm in mm in mm in
6 SKK 20 – 6 L–VG SKK 20 – 6 L–VK SKK 20 – 6–VS
8 SKK 20 – 8 L–VG SKK 20 – 8 L–VK SKK 20 – 8–VS
4500 10 SKK 20 – 10 L–VG SKK 20 – 10 L–VK SKK 20 – 10–VS
(315) 12 SKK 20 – 12 L–VG SKK 20 – 12 L–VK SKK 20 – 12–VS
L
15 SKK 20 – 15 L–VG SKK 20 – 15 L–VK SKK 20 – 15–VS
18 SKK 20 – 18 L–VG SKK 20 – 18 L–VK SKK 20 – 18–VS
22 SKK 20 – 22 L–VG SKK 20 – 22 L–VK SKK 20 – 22–VS
2300 28 SKK 20 – 28 L–VG SKK 20 – 28 L–VK SKK 20 – 28–VS
(160) 35 SKK 20 – 35 L–VG SKK 20 – 35 L–VK SKK 20 – 35–VS
42 SKK 20 – 42 L–VG SKK 20 – 42 L–VK SKK 20 – 42–VS
6 SKK 20 – 6 S–VG SKK 20 – 6 S–VK SKK 20 – 6–VS
8 SKK 20 – 8 S–VG SKK 20 – 8 S–VK SKK 20 – 8–VS
9100 10 SKK 20 – 10 S–VG SKK 20 – 10 S–VK SKK 20 – 10–VS
(630) 12 SKK 20 – 12 S–VG SKK 20 – 12 S–VK SKK 20 – 12–VS
S
14 SKK 20 – 14 S–VG SKK 20 – 14 S–VK SKK 20 – 14–VS
16 SKK 20 – 16 S–VG SKK 20 – 16 S–VK SKK 20 – 16–VS
5800 20 SKK 20 – 20 S–VG SKK 20 – 20 S–VK SKK 20 – 20–VS
(400) 25 SKK 20 – 25 S–VG SKK 20 – 25 S–VK SKK 20 – 25–VS
30 SKK 20 – 30 S–VG SKK 20 – 30 S–VK SKK 20 – 30–VS
(315)
38 SKK 20 – 38 S–VG SKK 20 – 38 S–VK SKK 20 – 38–VS
(Add C6F for Standard Finish)
HPU Item #39Hydraulic Power Unit - Item #38 - SKK20-716 UNF VE C6FHydraulic Power Unit - Item #38 - SKK20-716 UNF VE C6F
8-1078-107
Atlantic Industrial Technologies
9 ELECTRICAL DATASHEETS
Circuit Protectionw w w . a u t o m a t i o n d i r e c t . c o m / c i r c u i t - p r o t e c t i o n e31–5
Company Information
Systems Overview
Programmable Controllers
Field I/O
Software
C-more & other HMI
Drives
Soft Starters
Motors & Gearbox
Steppers/ Servos
Motor Controls
Proximity Sensors
Photo Sensors
Limit Switches
Encoders
Current Sensors
Pressure Sensors
Temperature Sensors
Pushbuttons/ Lights
Process
Relays/ Timers
Comm.
Terminal Blocks & Wiring
Power
Circuit Protection
Enclosures
Tools
Pneumatics
Safety
Appendix
Product Index
Part # Index
Volume 14
UL489 or UL1077?
What are your Circuit Protection Requirements?
An understanding of circuit types and circuit protection products is critical to ensure their proper application.
See NEC Sections 100, 430 and 409 for definitions.
The proper sizing of an overcurrent protection device is the responsibility of the customer and should be determined using the application standards of the NEC (National Electric Code), CEC (Canadian Electrical Code) or other applicable standards. Per fine print note of 2008 NEC
Section 100 "A current in excess of rating may be accommodated by certain equipment and conductors for a given set of conditions.
Therefore, the rules for overcurrent protection are specific for particular situations."
UL489
Branch Protection
UL1077
Supplementary Protection
What You Need to Know and Look For In Specifications Certifications – Standards – Acceptance
UL489
Branch Protection
UL1077
Supplementary Protection
• UL489 Listed or Recognized
• CSA C22.2 No. 5
• International ratings available depending on breaker type
• UL Recognized under UL1077
• CSA 22.2 No. 285
• IEC 60947-2 or IEC 898
Function
• Opens automatically on Overload and Short Circuit when properly applied with-in its ratings
• Protects wire and cable against Overload and Short Circuit
• Opens automatically on Overload and Short Circuit
• Provides additional equipment protection where branch circuit protection is already provided or not required
• Not suitable for the protection of branch circuit conductors Applications
• Branch circuit protection in control panels, panelboards, switchboards and motor control centers
• Motor overload and motor short circuit protection (UL489 Recognized motor circuit protectors) for control panels and motor control centers
• Used within appliances or other electrical equipment such as control circuits, control power transformers, relays, PLC I/O points and lighting circuits
• Ideal replacement for fuses that are applied as supplementary protection
Features
• Bolted down or DIN-rail mounted
• External handle mechanisms available
• Field mounted accessories
• Stand alone branch circuit protection
• Various levels of protection (curve type)
• High voltage and interruption levels (up to 100 kAIC @ 480V)
• DIN-Rail mounted
• Field mounted accessories
• Current limiting
• Various levels of protection (curve type)
• 10 kAIC @ 240 VAC
• 6 kAIC @ 277 VAC and 5 kAIC @ 480 VAC
• 10 kAIC @ 65 VDC kAIC = thousands of Amps interrupt capacity Summary
A Supplementary Protector can’t Be used for Branch Circuit Protection.
Understanding the difference between Branch Circuit Protection and Supplementary Protection helps to ensure their proper use.
Electrical Data Sheets - Item #01 - G3P-080Electrical Data Sheets - Item #01 - G3P-080
9-19-1
Circuit Protection 1 - 8 0 0 - 6 3 3 - 0 4 0 5e31–34 Volume 14
3P Series Molded Case Circuit Breakers Overview
Overview Designed to provide branch and feeder circuit protection in industrial control panels, this line of Molded Case Circuit Breakers supplies protection against overload in conductors and short circuit in connected equipment such as motors.
They are UL listed for installation in UL 508 control panels. Their small size, in relation to standard circuit breakers or other comparable devices, saves panel space. Four frame sizes and all standard accessories are available.
Listings
• UL 489MCCB, File: E7819
• Field-installed accessories:
UL file E64983
• CSA 22.2 No.5, File: 43556
• IEC 157-1
• NEMA Standards Pub. No. AB1-1993
Features
• UL489 listed performance for branch circuit overcurrent protection and disconnectingmeans
• Patented contact conductor designs featuring high-speed “blow-open” action, providing superior performance when high level fault currents produce extra-ordinary electromechanical forces
• Advanced arc extinguishing technology
• Toggle handle provides three positions (on/off/tripped) alongwith visual indicators
• Manufactured in ISO 9000 certified facilities
• HACR (heating, air conditioning and refrigeration) rated
• G-Frame and F-Frame breakers are suitable for reverse feed
• K-Frame and L-Frame breakers include 3-pole adjustablemagnetic trip.
G 3P - 020 - AUX
Molded Case Circuit Breaker Series (by frame size) G: 15 to 100 Amp F: 60 to 225 Amp K: 250 to 400 Amp L: 400 to 600 Amp
Accessory Description Code AUX: auxiliary contact UVAC: undervoltage release STAC: shunt trip AC STDC: shunt trip DC
Amp Rating
3 Pole
UVDC: undervoltage release
Molded Case Circuit Breakers Part Numbering System
Molded Case Circuit Breakers Technical Specifications
Circuit Breaker Type
Ampere Rating at 40°C
No.
Poles
Volts Type of
Trip*
Federal Specification W-C-375b
UL 489 Interrupting Ratings (rms Symmetrical Amperes) (kA)
AC DC
Volts AC (50/60 Hz) Volts DC
240 480 600 250** G-Frame 15 -100 3 480 250 N.I.T.U 13b 65 22 – 10
F-Frame 60 - 225 3 600 250 N.I.T.U 22a 65 35 18 10
K-Frame 250 - 400 3 600 250 I.T.U 23a 65 35 25 10
L-Frame 400 - 600 3 600 250 I.T.U 23a 65 35 25 22
*Note: N.I.T.U denotes non-interchangeable trip unit. I.T.U denotes interchangeable trip unit.
**Note: For DC or 1-phase AC applications, use the two outside poles of the 3-pole circuit breaker
Manufactured by Eaton Corporation
Note: These parts available for sale to North American locations only.
9-29-2
Circuit Protectionw w w . a u t o m a t i o n d i r e c t . c o m / c i r c u i t - p r o t e c t i o n e31–35
Information
Systems Overview
Programmable Controllers
Field I/O
Software
C-more & other HMI
Drives
Soft Starters
Motors & Gearbox
Steppers/ Servos
Motor Controls
Proximity Sensors
Photo Sensors
Limit Switches
Encoders
Current Sensors
Pressure Sensors
Temperature Sensors
Pushbuttons/ Lights
Process
Relays/ Timers
Comm.
Terminal Blocks & Wiring
Power
Circuit Protection
Enclosures
Tools
Pneumatics
Safety
Appendix
Product Index
Part # Index
Volume 14
G-Frame Accessory Selection Guide Part Number Price Description GHMVD06B <---> NEMA 1/12 rotary handle for G-Frame. Position indicating; lock-off feature. Shaft length: 6”
GHMVD12B <---> NEMA 1/12 rotary handle for G-Frame. Position indicating; lock-off feature. Shaft length: 12”
F0S03C <---> NEMA 1/12 flexible shaft handle for G-Frame. Flange mounted. Lockable. Shaft length: 3’
F0S06C <---> NEMA 1/12 flexible shaft handle for G-Frame. Flange mounted. Lockable. Shaft length: 6’
3TA100G6K <---> Multi-wire connector to allow 6 wires to be connected to the G-frame. UL for copper only. 14-6AWG. Package of 3
GDIN <---> DIN rail clip adapter to allow mounting of G-Frame unit on 35mm DIN rail. Pkg of 1 includes mounting hardware.
3P Series Molded Case Circuit Breakers 15 - 100 Amp G-Frame
G-Frame Series Three Pole Molded Case Circuit Breakers
Part Number Price Description Pre-Installed Accessories* Ampere Rating Voltage InterruptCapacity
G3P-015 <---> Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.
None
240VAC
480VAC
250VDC**
65kA 22kA 10kA
G3P-015-AUX <---> With auxiliary contact, SPDT
G3P-020 <---> Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.
None
G3P-020-AUX <---> With auxiliary contact, SPDT
G3P-025 <---> Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.
None 25
G3P-030 <---> None
G3P-030-AUX <--->
Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.
With auxiliary contact, SPDT
G3P-030-STAC <---> With 120 VAC shunt trip
G3P-030-STDC <---> With 24 VDC shunt trip
G3P-030-UVAC <---> With 120 VAC undervoltage release
G3P-040 <---> Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.
None 40
G3P-050 <---> None 50
G3P-060 <---> None
G3P-060-AUX <--->
Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.
With auxiliary contact, SPDT
G3P-060-STAC <---> With 120 VAC shunt trip
G3P-060-STDC <---> With 24 VDC shunt trip
G3P-060-UVAC <---> With 120 VAC undervoltage release
G3P-070 <---> Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.
None 70
G3P-080 <---> None 80
G3P-090 <---> None 90
G3P-100 <--->
Molded case circuit breaker with non-adjustable thermal magnetic trip; line and load lug termi-nals included.
None
G3P-100-AUX <---> With auxiliary contact, SPDT
G3P-100-STAC <---> With 120 VAC shunt trip
G3P-100-STDC <---> With 24 VDC shunt trip
G3P-100-UVAC <---> With 120 VAC undervoltage release
*Note: Available accessories are pre-installed on G-Frame and F-Frame Molded Case Circuit Breakers. They are not field installable or interchangeable.
** For DC or 1-phase AC applications, use the two outside poles of the 3-pole circuit breaker
G-Frame circuit breakers are available as a single unit, or with accessories pre-installed only. Accessories are not field installable on this frame size. G-Frame breakers are suitable for reverse feed use. All breakers include base mounting hardware for panel mount applications.
G3P-40
GHMVD12B
GDIN
F0S03C
3TA100G6K
AWG Wire Range Specifications Circuit Breaker
Ampere Rating
Wire Type
AWG Wire Range
Metric Wire Range mm2
G-Frame 15 - 20
Cu/AI 14 - 10 2.5 - 4
25 - 100 10 - 1/0 4 - 50
G-Frame Electrical Ratings
Volts Frequency Amperes ContactArrangement G-Frame Auxiliary Switch 240 VAC 50/60 Hz 6 1a/1b - SPDT
G-Frame Shunt Trip 120 VAC 50/60 Hz 1.1
24 VDC DC 5.7
G-Frame Undervoltage Release Mechanism
120 VAC 50/60 Hz 0.05
Dropout Voltage Pickup Voltage Min Max Max
38.5 VAC 77.0 VAC 93.5 VAC
Electrical Data Sheets - Item #01 - G3P-080Electrical Data Sheets - Item #01 - G3P-080
9-39-3 http://www.automationdirect.com/pn/G3P-030-STAC http://www.automationdirect.com/pn/G3P-030-STDC http://www.automationdirect.com/pn/G3P-030-UVAC http://www.automationdirect.com/pn/G3P-060-STAC http://www.automationdirect.com/pn/G3P-060-STDC http://www.automationdirect.com/pn/G3P-060-UVAC http://www.automationdirect.com/pn/G3P-100-STAC http://www.automationdirect.com/pn/G3P-100-STDC http://www.automationdirect.com/pn/G3P-100-UVAC http://www.automationdirect.com/pn/G3P-015-AUX http://www.automationdirect.com/pn/G3P-020-AUX http://www.automationdirect.com/pn/G3P-030-AUX http://www.automationdirect.com/pn/G3P-060-AUX http://www.automationdirect.com/pn/G3P-100-AUX http://www.automationdirect.com/pn/3TA100G6K http://www.automationdirect.com/pn/3TA100G6K http://www.automationdirect.com/pn/GHMVD06B http://www.automationdirect.com/pn/GHMVD12B http://www.automationdirect.com/pn/GHMVD12B http://www.automationdirect.com/pn/G3P-015 http://www.automationdirect.com/pn/G3P-020 http://www.automationdirect.com/pn/G3P-025 http://www.automationdirect.com/pn/G3P-030 http://www.automationdirect.com/pn/G3P-040 http://www.automationdirect.com/pn/G3P-050 http://www.automationdirect.com/pn/G3P-060 http://www.automationdirect.com/pn/G3P-070 http://www.automationdirect.com/pn/G3P-080 http://www.automationdirect.com/pn/G3P-090 http://www.automationdirect.com/pn/G3P-100 http://www.automationdirect.com/pn/F0S03C http://www.automationdirect.com/pn/F0S06C http://www.automationdirect.com/pn/F0S03C http://www.automationdirect.com/pn/GDIN
Circuit Protection 1 - 8 0 0 - 6 3 3 - 0 4 0 5e31–36
3P Series Molded Case Circuit Breakers 15 - 100 Amp G-Frame
M aximum
I n t e r r u p t i n g R a t i n g ( S e e T a b u l a t i o n A b o v e
M inimum
.5
.3
.2
.1
.05
.03
.02
.01
.005
.003
.002
.001
1,000
5,000
3,000
2,000
HO
UR
M
IN
U
TE
HO
UR
S
10,000
.5
.3
.2
.1
.05
.03
.02
.01
.005
.003
.002
.001
1,000
5,000
3,000
2,000
HO
UR
M
IN
U
TE
HO
UR
S
8060 907050 10
,0
0, ,0
,0
,0
,0
,0
,0
,0
,0
,0
8060 907050
0, ,0
,0
,0
,0
,0
,0
,0
,0
10,000
M ax im um Vo l ts
Type
G 3P
Con t inuous A mperes
15-60 70-100
G 3 P
500-1300 1300-1800
S y m m e t r i c a l R M S A m p e r e s 240 Volts
65,000
400-1100 700-1300
480 Volts 22,000
C U R R E N T I N P E R C E N T O F B R E A K E R T R I P U N I T R A T I N G
C i r c u i t B r e a k e r T i m e / C u r r e n t C u r v e s C a t a l o g T y p e G 3 P 1 5 - 1 0 0 A m p e r e s F o r a p p l i c a t i o n a n d c o o r d i n a t i o n p u r p o s e s o n l y . B a s e d o n 4 0 ˚ C a m b i e n t , c o l d s t a r t . C o n n e c t e d w i t h f o u r ( 4 ) f e e t o f r a t e d w i r e ( 6 0 / 7 5 ˚ C ) p e r t e r m i n a l . T e s t e d i n o p e n a i r w i t h c u r r e n t i n a l l p o l e s e x c e p t f o r i n s t a n t a n e o u s t r i p , s e e b e l o w
B r e a k e r
B r e a k e r I n s t a n t a n e o u s T r i p , A m p e r e s
A C V o l t s 6 0 H z
S i n g l e P o l e 2 P o l e s i n S e r i e s
I n t e r r u p t i n g R a t i n g ( U L L i s t e d ) B r e a k e r T y p e
I n s t a n t a n e o u s T r i p ( S e e T a b u l a t i o n a b o v e )
M a x i m u m I n t e r r u p t i n g T i m e
C U R R E N T I N P E R C E N T O F B R E A K E R T R I P U N I T R A T I N G
T
IM
E
IN
S E
C O
N D
S T
IM
E
IN
S
E C
O N
D S
9-49-4
Circuit Protection 1 - 8 0 0 - 6 3 3 - 0 4 0 5e31–50
3P Series Molded Case Circuit Breakers – Dimensions
4.875 (123.83)
2.625 (66.65)
.348 (8.83) Dia., 6 Holes in Cover.141 (3.57) Dia. 4 Holes
.281 (7.14) Dia C'Bores
.18 (4.57) Deep For Mounting Purposes
3.000 (76.17)
7̊
OFF
Front View Side View
On Off
.450 (11.43) diameter 6 holes
.110(2.8) dia.
x .310(7.9) deep, 2 holes accept #6 (M3.5) thread cutting screws
Push to Trip
6.000 (152.40)
3.375 (85.73)
.197(5.00) diameter hole
.328(8.33) diameter c'bore 1.938(49.23) deep from top.
.344(8.74) diameter c'bore .656(16.66) deep from bottom.
4 mounting holes for .164-32 (No. 8) x 1.500( M4 x0.7x 38.10) mounting screws.
4.13(105.0)
Side ViewFront View
60 - 225 Amp F-Frame
15 - 100 Amp G-Frame inches(mm) inches(mm)
9-59-5
Circuit Protection 1 - 8 0 0 - 6 3 3 - 0 4 0 5e31–52
Rotary Handle Accessory Selection Guide Part Number Price Description GHMVD06B <---> NEMA 1/12 black rotary handle for G-Frame MCCB. Shaft length: 6” GHMVD12B <---> NEMA 1/12 black rotary handle for G-Frame MCCB. Shaft length: 12” FHMVD12B <---> NEMA 1/12 black rotary handle for F-Frame MCCB. Shaft length: 12” HM1R12X <---> NEMA 4/4X black rotary handle for F-Frame MCCB. Shaft length: 12” HM1R24X <---> NEMA 4/4X black rotary handle for F-Frame MCCB. Shaft length: 24”
KHMVD12B <---> NEMA 1/12 black rotary handle for K-Frame MCCB. Shaft length: 12” HM3R12X <---> NEMA 4/4X black rotary handle for K-Frame MCCB. Shaft length: 12” HM3R24X <---> NEMA 4/4X black rotary handle for K-Frame MCCB. Shaft length: 24” LHMVD12B <---> NEMA 1/12 black rotary handle for L-Frame MCCB. Shaft length: 12” HM4R12X <---> NEMA 4/4X black rotary handle for K-Frame MCCB. Shaft length: 12” HM4R24X <---> NEMA 4/4X black rotary handle for K-Frame MCCB. Shaft length: 24”
Rotary Handle
Flex Shaft™ Flexible Handle
A universal rotary handle is available for each frame size of molded case circuit breaker. The handles are suitable for use with NEMA 1, 12, 4 or 4x enclosures. Features include:
• Large handle easily accommodates gloves
• Global ON/OFF markings (I/ON, O/OFF) and TRIP indication on handle
• Access Handle Lock-Off by pressing arrow on handle insert
• Door interlock and defeater
• Metal shaft and base
• Pipe valve operation (ON=Vertical, OFF=Horizontal) with 90 degree rotation
• UL 489, IEC 947-1/-2, CSA
Meeting crucial time limits for shutdown procedures is easier with an externally mounted handle. The flexible handle makes it possible to operate the circuit breaker externally, and can be used in enclosures of varying depths and heights. It can be used with NEMA 1, NEMA 3R and NEMA 12 enclosures, and accepts up to three padlock shackles.
Note: A minimum bending radius of four inches is necessary for proper operation.
GHMVD12B
HM1R12X
F0S03C
Flexible Handle Accessory Selection Guide Part Number Price Description
F0S03C <---> NEMA 1/12 flexible shaft handle for G-Frame MCCB. Shaft length: 3’ F0S06C <---> NEMA 1/12 flexible shaft handle for G-Frame MCCB. Shaft length: 6’ F1S03C <---> NEMA 1/12 flexible shaft handle for F-Frame MCCB. Shaft length: 3’ F1S06C <---> NEMA 1/12 flexible shaft handle for F-Frame MCCB. Shaft length: 6’ F3S03C <---> NEMA 1/12 flexible shaft handle for K-Frame MCCB. Shaft length: 3’ F3S06C <---> NEMA 1/12 flexible shaft handle for K-Frame MCCB. Shaft length: 6’ F4S04C <---> NEMA 1/12 flexible shaft handle for L-Frame MCCB. Shaft length: 4’ F4S06C <---> NEMA 1/12 flexible shaft handle for L-Frame MCCB. Shaft length: 6’
3P Series Molded Case Circuit Breakers – Accessories Field Mountable Accessories
Electrical Data Sheets - Item #01 - G3P-080Electrical Data Sheets - Item #01 - G3P-080
9-69-6 http://www.automationdirect.com/pn/GHMVD06B http://www.automationdirect.com/pn/GHMVD12B http://www.automationdirect.com/pn/FHMVD12B http://www.automationdirect.com/pn/KHMVD12B http://www.automationdirect.com/pn/LHMVD12B http://www.automationdirect.com/pn/GHMVD12B http://www.automationdirect.com/pn/HM1R12X http://www.automationdirect.com/pn/HM1R24X http://www.automationdirect.com/pn/HM3R12X http://www.automationdirect.com/pn/HM3R24X http://www.automationdirect.com/pn/HM4R12X http://www.automationdirect.com/pn/HM4R24X http://www.automationdirect.com/pn/HM1R12X http://www.automationdirect.com/pn/F0S03C http://www.automationdirect.com/pn/F0S03C http://www.automationdirect.com/pn/F0S06C http://www.automationdirect.com/pn/F1S03C http://www.automationdirect.com/pn/F1S06C http://www.automationdirect.com/pn/F3S03C http://www.automationdirect.com/pn/F3S06C http://www.automationdirect.com/pn/F4S04C http://www.automationdirect.com/pn/F4S06C
Circuit Protectionw w w . a u t o m a t i o n d i r e c t . c o m / c i r c u i t - p r o t e c t i o n e31–53
Information
Systems Overview
Programmable Controllers
Field I/O
Software
C-more & other HMI
Drives
Soft Starters
Motors & Gearbox
Steppers/ Servos
Motor Controls
Proximity Sensors
Photo Sensors
Limit Switches
Encoders
Current Sensors
Pressure Sensors
Temperature Sensors
Pushbuttons/ Lights
Process
Relays/ Timers
Comm.
Terminal Blocks & Wiring
Power
Circuit Protection
Enclosures
Tools
Pneumatics
Safety
Appendix
Product Index
Part # Index
Volume 14
Undervoltage Release Accessory Selection Guide Part Number Price Description UVH3LP08K <---> Field installable 110 - 127 VAC undervoltage release for K-Frame MCCB UVH4LP08K <---> Field installable 110 - 127 VAC undervoltage release for L-Frame MCCB UVH3LP21K <---> Field installable 24 VDC undervoltage release for K-Frame MCCB UVH4LP21K <---> Field installable 24 VDC undervoltage release for L-Frame MCCB
Undervoltage Release
This product monitors a voltage (typically a line voltage) and trips the circuit breaker when the voltage falls to between 70% and 35% of the solenoid coil rating. It consists of a continuous rated solenoid, with a plunger and tripping lever mounted in a plug-in module.
Note: The undervoltage release is a pre-installed accessory on G-Frame and F-Frame breakers.
UVH3LP21K
3P Series Molded Case Circuit Breakers – Accessories
Auxiliary Contact Accessory Selection Guide Part Number Price Description
A1X3PK <---> Field installable auxiliary contact for K-Frame MCCB, SPDT, 18” pigtail leads
A1X4PK <---> Field installable auxiliary contact for L-Frame MCCB, SPDT, 18” pigtail leads
Field Mountable Accessories Auxiliary Contact The auxiliary contact provides circuit breaker contact status information by monitoring the position of the molded cross bar which contains the moving contact arms. The auxiliary switch is used for remote indication and interlock system verification, and consists of one SPDT switch housed in a plug-in module. Each SPDT switch has one ‘a’ and one ‘b’ contact. When the circuit breaker contacts are open, the ‘a’ contact is open and the ‘b’ contact is closed.
Note: Field installable auxiliary contacts are not available for the G and F frame breakers.
For G and F frame auxiliary contacts, order breakers with -AUX as part of the part number.
Please see G and F-frame sections for available selections.
A1X3PK
K-Frame Undervoltage Release Mechanism
Supply Voltage
Dropout Voltage
Pickup Voltage VA Notes
Min Max Max 24 VDC 8.4 16.8 20.4 3.1 1. Endurance:
5000 electrical operations plus 1000 mechani-cal operatons.
2. 50/60 Hz
110 VAC2
44.5 77.0 93.5 1.8
120 VAC2 2.1
127 VAC2 2.4
L-Frame Undervoltage Release Mechanism
Supply Voltage
Dropout Voltage
Pickup Voltage VA
Notes Min Max Max
24 VDC 8.4 16.8 20.4 3.1 1. Endurance:
5000 electrical operations plus 1000 mechani-cal operatons.
2. 50/60 Hz
110 VAC2
44.5 77.0 93.5 1.8
120 VAC2 2.1
127 VAC2 2.4
K-Frame Electrical Ratings 1,2
Max Volts Frequency Max
Amperes Dielectric Withstand Voltage
Notes
K-Frame Auxiliary Switch
600 50/60 Hz 6
1. Endurance: 5000 electri-cal operations plus 1000 mechanical operatons.
2. Pigtail wire size: 18 AWG (0.82 mm2)
3. Non-inductive load
125 DC 0.503
250 DC 0.253
L-Frame Electrical Ratings 1,2
Max Volts Frequency Max
Amperes Dielectric Withstand Voltage
Notes
L-Frame Auxiliary Switch
600 50/60 Hz 6
1. Endurance: 5000 electrical operations plus 1000 mechanical operatons.
2. Pigtail wire size: 18 AWG
(0.82 mm2)
3. Non-inductive load
125 DC 0.503
250 DC 0.253
Electrical Data Sheets - Item #01 - G3P-080Electrical Data Sheets - Item #01 - G3P-080
9-79-7 http://www.automationdirect.com/pn/UVH3LP08K http://www.automationdirect.com/pn/UVH4LP08K http://www.automationdirect.com/pn/UVH3LP21K http://www.automationdirect.com/pn/UVH4LP21K http://www.automationdirect.com/pn/UVH3LP21K http://www.automationdirect.com/pn/A1X3PK http://www.automationdirect.com/pn/A1X4PK http://www.automationdirect.com/pn/A1X3PK
Circuit Protection 1 - 8 0 0 - 6 3 3 - 0 4 0 5e31–54
3P Series Molded Case Circuit Breakers – Accessories
Shunt Trip Accessory Selection Guide Part Number Price Description SNT3P11K <---> Field installable 110/240 VAC / 110/125 VDC shunt trip for K-Frame MCCB.
SNT4RP11K <---> Field installable 110/240 VAC shunt trip for L-Frame MCCB SNT3P04K <---> Field installable 12/24 VAC/DC shunt trip for K-Frame MCCB SNT4RP03K <---> Field installable 12/24 VAC/DC shunt trip for L-Frame MCCB
Shunt Trip The Shunt Trip provides remote controlled tripping of the circuit breaker. Consisting of an intermittent rated solenoid with a tripping plunger and a cutoff switch assembled to a plug-in module, shunt trip coils are designed to be applied at specific AC or DC volt-ages.
SNT3P04K
Field Mountable Accessories
L-Frame Shunt Trip
Supply Voltage
Min Operating Voltage
VA Supply Voltage
Min Operating Voltage
VA Notes
VVAACC 5500//6600 HHzz VVDDCC
1. Endurance: 5000 electrical operations plus 1000 mechanical operatons.
2. Approx. unlatching time: 6 ms Approx. total circuit breaker contact opening time: 18 ms
45 12
24 200 24 170
100 – – – 120 120 – – – 127 140 – – – 208 420 – – – 220 470 – – – 240 550 – – –
K-Frame Shunt Trip
Supply Voltage
Min Operating Voltage
VA Supply Voltage
Min Operating Voltage
VA Notes
VVAACC 5500//6600 HHzz VVDDCC
1. Endurance: 5000 electrical operations plus 1000 mechani-cal operatons.
2. Approx. unlatching time: 6 ms Approx. total circuit breaker contact opening time: 8 ms
45 12 8.4
24 200 24 170
100 110 77 110 120 120 120 77 130 127 140 125 77 140 208 420 – – – 220 470 – – – 240 550 – – –
Electrical Data Sheets - Item #01 - G3P-080Electrical Data Sheets - Item #01 - G3P-080
9-89-8 http://www.automationdirect.com/pn/SNT4RP11K http://www.automationdirect.com/pn/SNT4RP03K http://www.automationdirect.com/pn/SNT3P11K http://www.automationdirect.com/pn/SNT3P04K http://www.automationdirect.com/pn/SNT3P04K
Circuit Protectionw w w . a u t o m a t i o n d i r e c t . c o m / c i r c u i t - p r o t e c t i o n e31–55
Information
Systems Overview
Programmable Controllers
Field I/O
Software
C-more & other HMI
Drives
Soft Starters
Motors & Gearbox
Steppers/ Servos
Motor Controls
Proximity Sensors
Photo Sensors
Limit Switches
Encoders
Current Sensors
Pressure Sensors
Temperature Sensors
Pushbuttons/ Lights
Process
Relays/ Timers
Comm.
Terminal Blocks & Wiring
Power
Circuit Protection
Enclosures
Tools
Pneumatics
Safety
Appendix
Product Index
Part # Index
Volume 14
Six-wire Connector Accessory Selection Guide Part Number Price Description 3TA100G6K <---> For G-Frame MCCBs. Pkg. of 3. Wire size: 14 - 6 AWG, copper 3TA150F6K <---> For F-Frame MCCBs. Pkg. of 3. Wire size: 14 - 6 AWG, copper
Six-wire Connector
Replacement Lug Kit Accessory Selection Guide Part Number Price Description 3TA225FD <---> Replacement lug kit for F-Frame MCCB. Package of (3) terminals.
3TA401K <---> Replacement lug kit for K-Frame MCCB. 3-pole kit (one terminal per pole and one ter-minal cover).
3TA603LDK <---> Replacement lug kit for L-Frame MCCB. 3-pole kit (one terminal per pole and one ter-minal cover). Wire range 400-500 AWG (185-240 m²), 2 conductors.
Safety Door Hardware Selection Guide Part Number Price Description
C361KJ4 <--->
Handle length: 4”. Mounting hardware included for enclosures up to 40” tall. For taller enclosures that require a 3-point latch, the C361KR (purchase separately) will also be needed.
C361KJ6 <--->
Handle length: 6”. Mounting hardware included for enclosures up to 40” tall. For taller enclosures that require a 3-point latch, the C361KR (purchase separately) will also be needed.
C361KR <--->
Door Interlocking safety roller kit for use with the C361KJ4 and C361KJ6 safety handle kits when the SDN12 series enclosure is taller than 40 inches and 3-point latching is required. Kit includes roller and all hardware.
Din Rail Mount Clip Accessory Selection Guide Part Number Price Description
GDIN <---> Clip for mounting G-Frame to 35 mm Din rail. Mounting hardware included. Pkg of 1
Replacement Lug Kit
Din Rail Mounting Clip
NEMA 12 Safety Door Hardware
This is a field installable multi-wire connector which allows six wires to be connected to the load side (OFF) end terminals. It is used to distribute the load from the circuit breaker to multiple devices without the use of separate distribution terminal blocks. UL listed for copper only as used on the load side (OFF) end. Includes mounting hardware, insulators and tin-plated aluminum connectors.
Save valuable panel space and wiring time by eliminating terminal blocks. Multi-wire lug kit includes mounting hardware, insulators and tin-plated aluminum connectors to replace three mechanical load lugs. UL listed for copper only as used on the load side (OFF) end.
3TA100G6K
3TA401K
GDIN
Safety Handle shown on enclosure
3P Series Molded Case Circuit Breakers – Accessories Field Mountable Accessories
Type C361 door interlocking safety handle kits are designed for use with AutomationDirect 3P series MCCBs and flexible handle, when mounted in an SDN12, or equivalent, enclosure. These handles secure the SDN12 enclosure, protecting against unauthorized entry while the MCCB is in the ON position. Use them on enclosures with right side flanges only and material thickness from 16 gauge through 3/16”. All mounting hardware is included for enclosures up to 40” tall. The addition of the C361KR roller kit is necessary for enclosures taller than 40” that require a 3-point latch. See SDN12 Enclosures section for enclosure specifications
Release Screw
Handle in OFF position
Note: The 1/4” x 1/2” standard mill rectangular locking bar is not supplied with these kits. The bar is supplied with the enclosures.
Electrical Data Sheets - Item #01 - G3P-080Electrical Data Sheets - Item #01 - G3P-080
9-99-9 http://www.automationdirect.com/pn/3TA100G6K http://www.automationdirect.com/pn/3TA150F6K http://www.automationdirect.com/pn/3TA603LDK http://www.automationdirect.com/pn/3TA100G6K http://www.automationdirect.com/pn/3TA225FD http://www.automationdirect.com/pn/3TA401K http://www.automationdirect.com/pn/C361KJ4 http://www.automationdirect.com/pn/C361KJ6 http://www.automationdirect.com/pn/C361KJ4 http://www.automationdirect.com/pn/C361KJ6 http://www.automationdirect.com/pn/3TA401K http://www.automationdirect.com/pn/C361KR http://www.automationdirect.com/pn/C361KR http://www.automationdirect.com/pn/C361KR http://www.automationdirect.com/pn/C361KR
Part Number:
Approvals
Current Rating
Voltage Rating
SCCR
No. of Inputs Wire Range Torque
ScrewType No. of Outputs
Wire Range Torque Wire Range Torque
ScrewType Optional MarkingTag **(for DB16 and DB35)
Dimensions:
DB16*
80A 80A
600V AC 690V AC
10kA
1 1 8-4 AWG 6-16mm2
13.5lb.-in. 1.5Nm
Pozi Drive 2 6 6
(2x)8-4 AWG (2x)6-16mm2
13.5lb.-in. 1.5Nm (4x)14-10 AWG (4x)2.5-6mm2
7.2lb.-in. 0.8Nm Pozi Drive 2
MT2**
38049
80A 80A
600V AC 690V AC
100kA
1 1 8-4 AWG 6-16mm2
13.5lb.-in. 1.5Nm
Pozi Drive 2 6 6
(2x)8-4 AWG (2x)6-16mm2
13.5lb.-in. 1.5Nm (4x)14-10 AWG (4x)2.5-6mm2
7.2lb.-in. 0.8Nm Pozi Drive 2
DB35*
115A 125A
600V AC 690V AC
10kA
1 1 8-2 AWG 10-35mm2
31lb.-in. 3.5Nm
Pozi Drive 2 6 6
14-6 AWG 2.5-16mm2
17.5lb.-in. 2Nm
Pozi Drive 2
MT2**
38041
115A 125A
600V AC 690V AC
100kA
1 1 8-2 AWG 10-35mm2
13.5lb.-in. 3.5Nm
Pozi Drive 2 6 6
14-6 AWG 2.5-16mm2
17.5lb.-in. 2Nm
Pozi Drive 2
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com32
DB16• Quick mounting and wiring
• IP20 Finger Safe
• DIN Rail or Panel Mount
• Blocks fit with other DIN Rail mountable modular devices (height 95mm, depth 44.5mm)
• Accessories increase the number of outputs with only one input (applies only to 38041 and 38032)
• No caps to open / remove
• Material
Housing: Polyamide Metal Body: Brass
Fork Type Busbar 38045
38041
UL File E220514 UL File E98082 UL File E220514 UL File E98082
Accessories: ForkType Busbar Part No: 38045 to jump 2 Blocks
38046 to jump 8 Blocks can be cut
38041
38049 DB35 38041
One Phase Power Distribution Block
* Available in colors. Color Ordering Suffix Red R Blue BU Black BL Orange O Green G Yellow Y White W Beige BG Dark Brown DB
COLOR BLOCKS
(other than grey standard)
When ordering please add color suffix to Cat. No.
Example: CTS2.5U-N/R
Electrical Data Sheets - Item #02 - 38073Electrical Data Sheets - Item #02 - 38073
9-109-10
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 33
43 mm (1.69 in)
38.5 mm (1.52 in)
45 mm (1.77 in) m m (2
.2 in
5.2 mm (0.20 in)
17.4 mm (0.69 in)
13.8 mm (0.54 in)
19.9 mm (0.78 in)
5.2 mm (0.20 in) m m (2
.8 in
43 mm (1.69 in)
38.5 mm (1.52 in)
45 mm (1.77 in) m m (2
.2 in
5.2 mm (0.20 in)
17.4 mm (0.69 in)
13.8 mm (0.54 in)
19.9 mm (0.78 in)
5.2 mm (0.20 in) m m (2
.8 in
38032
38032
160A 160A
600V AC 690V AC
100kA
1 1 8-2/0AWG 10-70mm2
35.5lb.-in. 4Nm Hex 5
6 6 14-6 AWG 2.5-16mm2
17.5lb.-in. 2Nm Hex 3
38076
Part Number:
Approvals
Current Rating
Voltage Rating
SCCR
No. of Inputs Wire Range Torque
ScrewType No. of Outputs
Wire Range Torque
ScrewType
Dimensions:
38076
115A 125A
600V AC 690V AC
100kA
1 1 8-2 AWG 10-35mm2
53lb.-in. 6Nm Hex 4
10 10 14-4 AWG 2.5-16mm2
26.5lb.-in. 3Nm Hex 3
38074
38074
175A 175A
600V AC 690V AC
100kA
1 1 6-2/0AWG 16-70mm2
53lb.-in. 6Nm Hex 5
10 10 14-4 AWG 2.5-16mm2
26.5lb.-in. 3Nm Hex 3
Copper Jumper Bar 3803221
38032
UL File E98082 UL File E98082 UL File E98082
Accessories: Copper Jumper Bar (6x15 mm)
Part No: 3803221 for 2 Blocks 3803231 for 3 Blocks 3803241 for 4 Blocks can be cut
38032
One Phase Power Distribution BlockElectrical Data Sheets - Item #02 - 38073Electrical Data Sheets - Item #02 - 38073
9-119-11
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com34
38020 38019
Part Number:
Approvals
Current Rating
Voltage Rating
SCCR
No. of Inputs Wire Range Torque
ScrewType No. of Outputs
Wire Range Torque Wire Range Torque Wire Range Torque
ScrewType
Dimensions:
38020 38019
230A 250A 310A 400A
600V AC 690V AC 600V AC 690V AC
100kA 100kA
1 1 1 1 2-4/0AWG 35-120mm2 3/0-350mcm 95-185mm2
170lb.-in. 19Nm 230lb.-in. 25Nm Hex 6 Hex 8
11 11 11 11 (2x) 14-2AWG (2x) 2.5-35mm2 (2x) 14-2AWG (2x) 2.5-35mm2
31lb.-in. 3.5Nm 31lb.-in. 3.5Nm (5x) 14-6AWG (5x) 2.5-16mm2 (5x) 14-6AWG (5x) 2.5-16mm2
17.5lb.-in. 2Nm 17.5lb.-in. 2Nm (4x) 14-8AWG (4x) 2.5-10mm2 (4x) 14-8AWG (4x) 2.5-10mm2
17.5lb.-in. 2Nm 17.5lb.-in. 2Nm standard screwdriver standard screwdriver
UL File E98082 UL File E98082
• Quick mounting and wiring
• IP20 Finger Safe
• DIN Rail or Panel Mount
• Blocks fit with other DIN Rail mountable modular devices (height 95mm, depth 44.5mm)
• Accessories increase the number of outputs with only one input.
• No caps to open or remove
• Material
Housing: Polyamide Metal Body: Brass
One Phase Power Distribution BlockElectrical Data Sheets - Item #02 - 38073Electrical Data Sheets - Item #02 - 38073
9-129-12
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 35
38075 38073
Part Number:
Approvals
Current Rating
Voltage Rating
SCCR
No. of Inputs Wire Range Torque
ScrewType No. of Outputs
Wire Range Torque
ScrewType
Dimensions:
38075 38073
115A 115A 175A 175A
600V AC 690V AC 600V AC 690V AC
100kA 100kA
3x1 3x1 3x1 3x1 8-2AWG 10-35mm2 8-2/0AWG 10-70mm2
31lb.-in. 3.5Nm 35.5lb.-in. 4Nm Hex 4 Hex 5
3x6 3x6 3x6 3x6 14-4AWG 2.5-16mm2 14-4AWG 2.5-16mm2
17.5lb.-in. 2Nm 17.5 lb.-in. 2Nm Hex 3 Hex 3
3 Pole 3 Pole
• Quick mounting and wiring
• IP20 Finger Safe
• DIN Rail or Panel Mount
• Blocks fit with other DIN Rail mountable modular devices
• Same compact size for both ratings
• No caps to open or remove
• Material
Housing: Polyamide Metal Body: Brass
UL File E98082 UL File E98082
Three Phase Power Distribution BlockElectrical Data Sheets - Item #02 - 38073Electrical Data Sheets - Item #02 - 38073
9-139-13
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com36
• Quick mounting and wiring
• IP20 Finger Safe
• DIN Rail or Panel Mount
• No caps to open or remove
• Material
Housing: Polyamide Metal Body: Aluminum
38064 38057
Part Number:
Approvals
Current Rating
Voltage Rating
No. of Inputs Wire Range Torque
ScrewType No. of Outputs
Wire Range Torque
ScrewType
Dimensions:
38064
175A 175A
600V AC 690V AC
1 1 14-1AWG 2.5mm2-50mm2
106.2lb.-in. 12Nm Hex 5
1 1 14-1AWG 2.5mm2-50mm2
106.2lb.-in. 12Nm Hex 5
38057
335A 400A
600V AC 690V AC
1 1 6AWG-400MCM 16mm2-185mm2
221lb.-in. 25Nm Hex 10
1 1 6AWG-400MCM 16mm2-185mm2
221lb.-in. 25Nm Hex 10
38059
840A 800A
600V AC 690V AC
2 2 3AWG-600MCM 25-300mm2
310lb.-in. 35Nm Hex 10
2 2 3AWG-600MCM 25-300mm2
310lb.-in. 35Nm Hex 10
.6 m m
(2 .3 in)
25.4 mm (1.0 in)
50 mm (1.97 in)
.3 m m
(2 .8 in)
.7 m m
(1 .3 in)
.2 m m
(1 .7 in)
39 mm [1.54 in]
7 mm [0.28 in]
5.
m m [5
.7 in
7.5 mm [0.30 in]
4.
m m [4
.9 in
12 mm [0.47 in]
7 mm [0.28 in]
80.5 mm [3.17 in]
53.5 mm [2.11 in] m m
[5 .7 in m m
[5 .0 in
72 mm [2.83 in]
80.5 mm [3.17 in]
38059
UL File E98082 UL File E98082 UL File E98082
Splicer Blocks Electrical Data Sheets - Item #02 - 38073Electrical Data Sheets - Item #02 - 38073
9-149-14
Motor Controlsw w w . a u t o m a t i o n d i r e c t . c o m / m o t o r - c o n t r o l s e17-5
Information
Systems Overview
Programmable Controllers
Field I/O
Software
C-more & other HMI
Drives
Soft Starters
Motors & Gearbox
Steppers/ Servos
Motor Controls
Proximity Sensors
Photo Sensors
Limit Switches
Encoders
Current Sensors
Pressure Sensors
Temperature Sensors
Pushbuttons/ Lights
Process
Relays/ Timers
Comm.
Terminal Blocks & Wiring
Power
Circuit Protection
Enclosures
Tools
Pneumatics
Safety
Appendix
Product Index
Part # Index
Features
• 5 to 100 hp at 480 VAC
• cULus and CSA approval, CEmark, meets JIS and IEC standards.
• Models SC-E02-xxx to SC-E4-xxx have 3-polemain circuits and come in three sizes with widths of 43mm, 54mm, and 67mm.
•Models SC-E1-xxx to SC-E7-xxx employ a box terminal structure; allowingwires to be connected directly to themain circuit.
• Has a finger-protection terminal structure that prevents the exposure of live parts.
• Models SC-E5-xxx to SC-E7-xxx use a SUPERMAGNETTM (AC-input/DC-output operation) for high operating reliability and requires no surge suppressor.
Small Size
• SC-E02-xxx to E05-xxx: 43mmwide
• SC-E1-xxx to E2S-xxx: 54mmwide
• SC-E3-xxx, E4-xxx: 67mmwide
• SC-E5-xxx: 88mmwide
Safety
• Terminals with finger-touch protection (DIN 57106/VDE 0106 Teil100)
Utility
• Box lug terminal construction
• Long electrical life
• Easy to wire
Environmental
• Low power consumption
• Recycled thermoplastic resin used for plastic parts.
• The names ofmaterials are indicated on all major parts to facilitate recycling
Standards & Approvals
• UL listed , file E42419, Standard UL 508
• cUL listed, file E42419, Standard CSA C 22.2 No.14
• VDE 0660
• JIS C 8201-4-1
• IEC 60947-4-1 / EN 60947-4-1
• CE compliant
Optional accessories
• Auxiliary contact blocks
• Coil surge suppression units
• Replacement coils for contactor sizes SC-E5 and larger
Fuji Duo Series SC-E Contactors
SC-E2S
SC-E Series Contactors Specifications - UL and CSA
Model Price
No m in al Co il
Vo lta ge
Rated Capacity (HP)
Ra te d
AC
-3
Cu rr en t( A)
[n ot e 1]
Ra te d
AC
-1
Th er m al Cu rr en t
(A no te
2]
SC
CR
Ra tin gs
(K A)
Ra te d In su la tio n
Vo lta ge
(V
Fr am e W id th
(m m
3-Phase Motor 1-Phase Motor
200V 220– 240V
440– 480V
550– 600V
100– 120V
220– 240V
SC-E02-24VAC <---> 24VAC
2 2 5 5 1/3 1 9 20
5 690 43
SC-E02-110VAC <---> 110VAC
SC-E02-220VAC <---> 220VAC
SC-E02-440VAC <---> 440-480VAC
SC-E02-500VAC <---> 500-550VAC
SC-E02G-24VDC <---> 24VDC
SC-E03-24VAC …