Product Information Packet: CEM3581T - 1HP,1760RPM,3PH,60HZ,143TC,0519M,TEFC,F1 Hydraulic Power Unit - Item #04 - CEM3581THydraulic Power Unit - Item #04 - CEM3581T
8-248-24
HPU Item #05Hydraulic Power Unit - Item #05 - 2GG1U11RHydraulic Power Unit - Item #05 - 2GG1U11R
8-258-25
8-268-26
8-278-27
8-288-28
8-298-29
NEMA Frame Motors
44 magnaloy coupling company 501 Commerce Drive Alpena, MI 49707 989 356-2186 A Division of Douville Johnston Corporation Fax: 989 354-4190 http://www.magnaloy.com
TABLE 6 - NEMA ‘C’ Face Motor Dimensions
182UC
184UC
213UC
215UC
254UC
256UC
284UC
286UC
324USC
326USC
324UC
326UC
364USC
365USC
364UC
365UC
404USC
405USC
404UC
405UC
444USC
445USC
444UC
445UC
AH 2.125 2.75 3.50 4.625 3.00 5.375 3.50 6.125 4.00 6.875 4.00 8.375
U 7/8 1 1/8 1 3/8 1 5/8 1 5/8 1 7/8 1 7/8 2 1/8 2 1/8 2 3/8 2 1/8 2 7/8 S 3/16 1/4 5/16 3/8 3/8 1/2 1/2 1/2 1/2 5/8 1/2 3/4
AK 4.50 8.50 8.50 10.50 12.50 12.50 12.50 12.50 12.50 12.50 16.00 16.00
AJ 5.875 7.25 7.25 9.00 11.00 11.00 11.00 11.00 11.00 11.00 14.00 14.00
BF 3/8-16 1/2-13 1/2-13 1/2-13 5/8-11 5/8-11 5/8-11 5/8-11 5/8-11 5/8-11 5/8-11 5/8-11
HP* 1
7.5
056C
143TC
145TC
182TC
184TC
213TC
215TC
254TC
256TC
284TSC
286TSC
284TC
286TC
324TSC
326TSC
324TC
326TC
364TSC
365TSC
364TC
365TC
404TSC
405TSC
404TC
405TC
444TSC
449TSC
444TC
449TC
AH 2.062 2.125 2.625 3.125 3.75 3.00 4.375 3.50 5.00 3.50 5.625 4.00 7.00 4.50 8.25 U 5/8 7/8 1 1/8 1 3/8 1 5/8 1 5/8 1 7/8 1 7/8 2 1/8 1 7/8 2 3/8 2 1/8 2 7/8 2 3/8 3 3/8 S 3/16 3/16 1/4 5/16 3/8 3/8 1/2 1/2 1/2 1/2 5/8 1/2 3/4 5/8 7/8 AK 4.50 4.50 8.50 8.50 8.50 10.50 10.50 12.50 12.50 12.50 12.50 12.50 12.50 16.00 16.00 AJ 5.875 5.875 7.25 7.25 7.25 9.00 9.00 11.00 11.00 11.00 11.00 11.00 11.00 14.00 14.00 BF 3/8-16 3/8-16 1/2-13 1/2-13 1/2-13 1/2-13 1/2-13 5/8-11 5/8-11 5/8-11 5/8-11 5/8-11 5/8-11 5/8-11 5/8-11
HP* 1/4
1/2
7.5
U-Frame Dimensions
T-Frame Dimensions
* Horse Power at 1750 RPM
Magnaloy Cast Aluminum Mounts
Magnaloy Horizontal Pump/Motor Mounts
MAGNALOY CAST ALUMINUM MOUNTS are permanent mold cast of lightweight, high strength aluminum alloy and incorporate many unique design features. Custom molded OSHA orange coupling access covers are included for mounts larger than motor group size 056. These covers are quickly and securely retained via a lip-tab on one end and a single self-tapping screw on the other. Magnaloy’s horizontal mounts are supplied with a pre-cast drain hole for residual fluids. This unique feature assists in quick detection of leaky seals and other trouble areas.
Using Magnaloy’s Pump/Motor Mounts ensure a lightweight, high strength, precision mount for efficient assembly, quiet operation, accurate shaft alignment and complete coupling concealment.
MAGNALOY’S HORIZONTAL PUMP/MOTOR MOUNTS are available for mounting NEMA C’Face motors in frame sizes 56C through 449TSC to most SAE and Metric 2 and 4 bolt pump flanges.
A MOUNT KIT is included which contains all the bolts and washers required to attach the pump and motor to the mount.
HPU Item #06.1Hydraulic Power Unit - Item #06.1 - M056422AHydraulic Power Unit - Item #06.1 - M056422A
8-308-30
Horizontal Pump/Motor Mounts
55magnaloy coupling company 501 Commerce Drive Alpena, MI 49707 989 356-2186 A Division of Douville Johnston Corporation Fax: 989 354-4190 http://www.magnaloy.com
Horizontal Mount Selection Method
1. Check TABLES 2 thru 5 to determine pump flange size.
2. Measure the pump shaft length from the shaft end to the flange mounting face and ADD to the motor shaft length shown in TABLE 6. An additional 1/16 inch (minimum) is recommended for shaft end clearance.
3. Refer to the appropriate TABLE (7 thru 11) according to the NEMA motor frame size and locate the applicable pump flange selection form STEP 1, above.
4. Select the mount length option (dimension ‘XM’ or ‘M’ in tables) based on the minimum length determined in STEP 2, above.
5. Check for proper clearance between the mount inner surfaces and the coupling O.D. (dimension ‘Z’ and ‘CL’ in tables).
Dimensional data for Magnaloy Couplings is shown in TABLE 1 for reference. A complete Magnaloy Coupling catalog is available upon request or visit www.magnaloy.com.
Consult your Magnaloy Distributor for Magnaloy’s Product CD ROM which includes the Magnaloy Pump/Motor Mount
Selection Program for easy, computerized mount selection.
TABLE 7 - NEMA Frames 56C, 143TC/145TC, 182UC/184UC Horizontal Mounting (or Vertical Mounting - Option A)
USA4F17 4 Bolt 1.782 2.84 5/16-18 M056354F 2.81 3.50 M056424F 3.56 4.25 M056454F 3.81 4.50
SAE AA 2 Bolt 2.001 3.25 3/8-16 M056352AA 2.81 3.50 M056422AA 3.56 4.25 M056452AA 3.81 4.50
SAE A 2(4) Bolt 3.251 4.19 3/8-16 4.12 3/8-16 M056352A 2.81 3.50 M056422A 3.56 4.25 M056452A 3.81 4.50
80 2A/B4 2(4) Bolt 80.01mm 109mm 3/8-16 103mm 5/16-18 M0563580M 2.81 3.50 M0564280M 3.56 4.25 M0564580M 3.81 4.50
80 S4 4 Bolt 80.01mm 100mm 5/16-18 M0563580MS 2.81 3.50 M0564280MS 3.56 4.25 M0564580MS 3.81 4.50
USA4F17 4 Bolt 1.782 2.84 5/16-18 M056504F 4.31 5.00 M056524F 4.56 5.25
SAE AA 2 Bolt 2.001 3.25 3/8-16 M056502AA 4.31 5.00 M056522AA 4.56 5.25
SAE A 2(4) Bolt 3.251 4.19 3/8-16 4.12 3/8-16 M056502A 4.31 5.00 M056522A 4.56 5.25
SAE B 2(4) Bolt 4.001 5.75 1/2-13 5.00 1/2-13 M056502B* 3.93 5.00 M056522B* 4.18 5.25
80 2A/B4 2(4) Bolt 80.01mm 109mm 3/8-16 103mm 5/16-18 M0565080M 4.31 5.00 M0565280M 4.56 5.25
80 S4 4 Bolt 80.01mm 100mm 5/16-18 M0565080MS 4.31 5.00 M0565280MS 4.56 5.25
80 S4 4 Bolt 80.01mm 100mm 5/16-18 M05650100M* 3.93 5.00M05652100M* 4.18 5.25
5.8
5.8
7/
7/
6.8
6.8
4.5
4.5
MOTOR END DATA
AJ BF BD AK
MOTOR END DATA
AJ BF BD AK
PUMP FLANGE PUMP END DATA 3.50 LENGTH 4.25 LENGTH 4.50 LENGTH
PUMP FLANGE PUMP END DATA 5.00 LENGTH 5.25 LENGTH
XAK XAJ2 XBF2 XAJ4 XBF4 MOUNT NO. CL XM MOUNT NO. CL XM MOUNT NO. CL XM
XAK XAJ2 XBF2 XAJ4 XBF4 MOUNT NO. CL XM MOUNT NO. CL XM
RADIAL CLEARANCE “Z” = 4.15
RADIAL CLEARANCE “Z” = 4.15
* RADIAL CLEARANCE “Z” = 4.10
HPU Item #06.1Hydraulic Power Unit - Item #06.1 - M056422AHydraulic Power Unit - Item #06.1 - M056422A
8-318-31
66 magnaloy coupling company 501 Commerce Drive Alpena, MI 49707 989 356-2186 A Division of Douville Johnston Corporation Fax: 989 354-4190 http://www.magnaloy.com
TABLE 8A - NEMA Frames 182TC - 256TC, 213UC - 256UC
TABLE 8B - NEMA Frames 182TC - 256TC, 213UC - 256UC
Horizontal Mounting (or Vertical Mounting - Option A)
Horizontal Mounting
MOTOR END DATA
AJ BF BD AK
MOTOR END DATA
AJ BF BD AK
MOTOR END DATA
AJ BF BD AK
7.2
7.2 /3 9.0
8.5
7.2
/3
/3
9.0
8.5
9.0
8.5
XAK XAJ2 XBF2 XAJ4 XBF4 MOUNT NO. CL M MOUNT NO. CL M MOUNT NO. CL M
XAK XAJ2 XBF2 XAJ4 XBF4 MOUNT NO. CL M MOUNT NO. CL M MOUNT NO. CL M
XAK XAJ2 XBF2 XAJ4 XBF4 MOUNT NO. CL M MOUNT NO. CL M
USA4F17 4 Bolt 1.782 2.84 5/16-18 M182474F 4.00 4.75 M182504F 4.31 5.00 M182524F 4.31 5.25
SAE AA 2 Bolt 2.001 3.25 3/8-16 M182472AA 4.00 4.75 M182502AA 4.31 5.00 M182522AA 4.31 5.25
SAE A 2(4) Bolt 3.251 4.19 3/8-16 4.12 3/8-16 M182472A 4.00 4.75 M182502A 4.31 5.00 M182522A 4.31 5.25
80 2A/B4 2(4) Bolt 80.01mm 109mm 3/8-16 103mm 5/16-18 M1824780M 4.00 4.75 M1825080M 4.31 5.00 M1825280M 4.31 5.25
80 S4 4 Bolt 80.01mm 100mm 5/16-18 M1824780MS 4.00 4.75 M1825080MS 4.31 5.00 M1825280MS 4.31 5.25
SAE B 2(4) Bolt 4.001 5.75 1/2-13 5.00 1/2-13 M182522B 4.50 5.25 M182582B 5.06 5.81 M182602B 5.25 6.00
SAE C 2(4) Bolt 5.001 7.12 5/8-11 6.38 1/2-13 M182522C 4.50 5.25 M182582C 5.06 5.81 M182602C 5.25 6.00
100 A2/B4 2(4) Bolt 100.01mm 140mm 1/2-13 125mm 3/8-16 M18252100M 4.50 5.25 M18258100M 5.06 5.81 M18260100M 5.25 6.00
125 A2/B4 2(4) Bolt 125.01mm 180mm 5/8-11 160mm 1/2-13 M18252125M 4.50 5.25 M18258125M 5.06 5.81 M18260125M 5.25 6.00
RADIAL CLEARANCE “Z” = 5.00
USA4F17 4 Bolt 1.782 2.84 5/16-18 M182584F 5.06 5.81 M182684F 6.06 6.81
SAE AA 2 Bolt 2.001 3.25 3/8-16 M182582AA 5.06 5.81 M182682AA 6.06 6.81
SAE A 2(4) Bolt 3.251 4.19 3/8-16 4.12 3/8-16 M182582A 5.06 5.81 M182682A 6.06 6.81
80 2A/B4 2(4) Bolt 80.01mm 109mm 3/8-16 103mm 5/16-18 M1825880M 5.06 5.81 M1826880M 6.06 6.81
80 S4 4 Bolt 80.01mm 100mm 5/16-18 M1825880MS 5.06 5.81 M1826880MS 6.06 6.81
RADIAL CLEARANCE “Z” = 5.00
RADIAL CLEARANCE “Z” = 5.00
PUMP FLANGE PUMP END DATA 4.75 LENGTH 5.0 LENGTH 5.25 LENGTH
PUMP FLANGE PUMP END DATA 5.25 LENGTH 5.81 LENGTH 6.00 LENGTH
PUMP FLANGE PUMP END DATA 5.81 LENGTH 6.81 LENGTH
182-A Casting
182-B Casting
HPU Item #06.1Hydraulic Power Unit - Item #06.1 - M056422AHydraulic Power Unit - Item #06.1 - M056422A
8-328-32
77magnaloy coupling company 501 Commerce Drive Alpena, MI 49707 989 356-2186 A Division of Douville Johnston Corporation Fax: 989 354-4190 http://www.magnaloy.com
MOTOR END DATA
AJ BF BD AK
7.2
9.0
.00
.00 /3 .00
.00
/3 .00
.50
/3
/3 .00
.50
9.0 8.5
RADIAL CLEARANCE “Z” = 5.00
RADIAL CLEARANCE “Z” = 6.40
RADIAL CLEARANCE “Z” = 7.74
RADIAL CLEARANCE “Z” = 10.75
XAK XAJ2 XBF2 XAJ4 XBF4 MOUNT NO. CL M MOUNT NO. CL M
PUMP FLANGE PUMP END DATA 6.88 LENGTH 7.50 LENGTH 8.69 LENGTH
SAE B 2(4) Bolt 4.001 5.75 1/2-13 5.00 1/2-13 M182682B 6.06 6.81 M182702B 6.25 7.00
SAE C 2(4) Bolt 5.001 7.12 5/8-11 6.38 1/2-13 M182682C 6.06 6.81 M182702C 6.25 7.00
100 A2/B4 2(4) Bolt 100.01mm 140mm 1/2-13 125mm 3/8-16 M18268100M 6.06 6.81 M18270100M 6.25 7.00
125 A2/B4 2(4) Bolt 125.01mm 180mm 5/8-11 160mm 1/2-13 M18268125M 6.06 6.81 M18270125M 6.25 7.00
PUMP FLANGE PUMP END DATA 6.81 LENGTH 7.00 LENGTH
PUMP FLANGE PUMP END DATA 7.62 LENGTH 8.75 LENGTH
PUMP FLANGE PUMP END DATA 8.88 LENGTH
TABLE 9 - NEMA Frames 284TC/TSC - 286TC/TSC, 284UC/286UC
TABLE 10 - NEMA Frames 324TC/TSC - 405TC/TSC, 324UC/USC - 405UC/USC
TABLE 11 - NEMA Frames 444TC/TSC - 449TC/TSC, 444UC/USC - 445UC/USC
MOTOR END DATA
AJ BF BD AK
MOTOR END DATA
AJ BF BD AK
MOTOR END DATA
AJ BF BD AK
SAE A 2(4) Bolt 3.251 4.19 3/8-16 4.12 3/8-63 M284682A 6.00 6.88 M284752A 6.62 7.50 M284862A 7.81 8.69
SAE B 2(4) Bolt 4.001 5.75 1/2-13 5.00 1/2-13 M284682B 6.00 6.88 M284752B 6.62 7.50 M284862B 7.81 8.69
SAE C 2(4) Bolt 5.001 7.12 5/8-11 6.38 1/2-13 M284682C 6.00 6.88 M284752C 6.62 7.50 M284862C 7.81 8.69
80 A2/B4 2(4) Bolt 80.01mm 109mm 3/8-16 103mm 5/16-18 M2846880M 6.00 6.88 M2847580M 6.62 7.50 M2848680M 7.81 8.69
80 S4 4 Bolt 80.01mm 100mm 5/16-18 M2846880MS 6.00 6.88 M2847580MS 6.62 7.50 M2848680MS 7.81 8.69
100 A2/B4 2(4) Bolt 100.01mm 140mm 1/2-13 125mm 3/8-16 M28468100M 6.00 6.88 M28475100M 6.62 7.50 M28486100M 7.81 8.69
125 A2/B4 2(4) Bolt 125.01mm 180mm 5/8-11 160mm 1/2-13 M28468125M 6.00 6.88 M28475125M 6.62 7.50 M28486125M 7.81 8.69
SAE B 2(4) Bolt 4.001 5.75 1/2-13 5.00 1/2-13 M324762B 6.75 7.62 M324872B 7.88 8.75
SAE C 2(4) Bolt 5.001 7.12 5/8-11 6.38 1/2-13 M324762C 6.75 7.62 M324872C 7.88 8.75
SAE D 2(4) Bolt 6.001 9.00 3/4-10 9.00 3/4-10 M324762D 6.75 7.62 M324872D 7.88 8.75
100 A2/B4 2(4) Bolt 100.01mm 140mm 1/2-13 125mm 3/8-16 M32476100M 6.75 7.62 M32487100M 7.88 8.75
125 A2/B4 2(4) Bolt 125.01mm 180mm 5/8-11 160mm 1/2-13 M32476125M 6.75 7.62 M32487125M 7.88 8.75
160 A2/B4 2(4) Bolt 160.01mm 224mm 3/4-10 200mm 5/8-11 M32476160M 6.75 7.62 M32487160M 7.88 8.75
180 B4 4 Bolt 180.01mm 224mm 5/8-11 M32476180M 6.75 7.62 M32487180M 7.88 8.75
SAE C 2(4) Bolt 5.001 7.12 5/8-11 6.38 1/2-13 M444882C 7.12 8.88
SAE D 2(4) Bolt 6.001 9.00 3/4-10 9.00 3/4-10 M444882D 7.12 8.88
SAE E 2 Bolt 6.501 12.50 1-8 M444882E 7.12 8.88
XAK XAJ2 XBF2 XAJ4 XBF4 MOUNT NO. CL M MOUNT NO. CL M MOUNT NO. CL M
XAK XAJ2 XBF2 XAJ4 XBF4 MOUNT NO. CL M MOUNT NO. CL M
XAK XAJ2 XBF2 XAJ4 XBF4 MOUNT NO. CL M
HPU Item #06.1Hydraulic Power Unit - Item #06.1 - M056422AHydraulic Power Unit - Item #06.1 - M056422A
8-338-33
Hydraulic Products
Industrial Supplies and Expertise
Material: Magnesium Titanium
Coupling Size
Bore X Key
(in) Order No. Mfr. No. Net Price
3/8 X 3/32 MA4400016 M10001203 $14.44
7/16 X 3/32 MA4400017 M10001403 14.44
7/16 X 1/8 MA4400018 M10001404 14.44
1/2 X 1/8 MA4400019 M10001604 14.44
9/16 X 1/8 MA4400021 M10001804 14.44
5/8 X 5/32 MA9781550 M10002005 14.44
5/8 X 3/16 MA9621528 M10002006 14.44
11/16 X 3/16 MA4400025 M10002206 14.44
3/4 X 1/8 MA4400026 M10002404 14.44
3/4 X 3/16 MA2540314 M10002406 14.44
7/8 X 3/16 MA2571277 M10002806 14.44
7/8 X 1/4 MA4400029 M10002808 14.44
1 X 3/16 MA4400030 M10010006 14.44
1 X 1/4 MA1610992 M10010008 14.44
1 1/8 X 1/4 MA8209497 M10010408 14.44
1/2 X 1/8 MA2518115 M20001604 16.97
9/16 X 1/8 MA4400045 M20001804 16.97
5/8 X 5/32 MA5386637 M20002005 16.97
5/8 X 3/16 MA1184805 M20002006 16.97
11/16 X 3/16 MA4400048 M20002206 16.97
3/4 X 1/8 MA1193033 M20002404 16.97
3/4 X 3/16 MA5190003 M20002406 16.97
7/8 X 3/16 MA7167691 M20002806 16.97
7/8 X 1/4 MA5542560 M20002808 16.97
1 X 3/16 MA1917328 M20010006 16.97
1 X 1/4 MA7490210 M20010008 16.97
1 1/8 X 1/4 MA2518117 M20010408 16.97
1 1/4 X 1/4 MA5240084 M20010808 16.97
1 1/4 X 5/16 MA4400059 M20010810 16.97
1 3/8 X 5/16 MA2511102 M20011210 16.97
Flexible Coupling Round Bore Hub
Accumulator Discharge Valve The ADV1-16 is a poppet-type, normally open, externally piloted, screw-in, cartridge-type accumulator discharge valve. In its unpiloted position, this valve remains open between port 1 and port 2 until suffi cient pilot pressure is applied to port 3. Flow is then blocked from port 1 to port 2. Port 2 is connected to tank.
Order No. Mfr. No. Model No.
Port Size Approximate Dimensions Net Price
MA3324664 02-162712 ADV1-16-12H-100-00 SAE-12 5 in x 2.5 in x 5 in $148.51
Max. Pressure: 3,000 psi Max. Flow: 8 gpm Min. Pilot Pressure: 60 psi Cavity: C-16-3S Housing Material: Aluminum Filtration: Code 18/16/13 Pilot Ratio: 100:1
Flexible Coupling Insert
Flexible Drive Couplings
Select coupler size and insert by your needed horsepower and RPM requirements, then select shaft diameter and keyway size needed from the table below. Order insert and coupling halves separately.
Magnaloy is the original lightweight, heavy-duty, fl exible drive coupling. Lightweight magnesium construction makes Magnaloy couplings 76% lighter than cast iron and 36% lighter than aluminum units.
Material Color Temperature
Range Neoprene Black -30 °F to 250 °F Urethane Yellow -30 °F to 150 °F
Hytrel Blue-green -65 °F to 300 °F
Coupling Size
Max. Bore Size (in) Order No. Material
Torque Rating (in lb)
HP @
100 rpm
HP @
1200 rpm
HP @
1800 rpm Net Price
100 1 1 / 8 MA9839367 Neoprene 340.7 0.55 6.50 9.80 $4.49 MA3531180a Urethane 511.0 0.82 9.80 14.70 7.04 MA6913664 Hytrel 1,022.1 1.65 19.80 29.70 7.73
200 1 3 / 8 MA9628895 Neoprene 398.3 0.64 7.60 11.50 5.91 MA2286778a Urethane 597.4 0.96 11.50 17.20 8.98 MA2541444 Hytrel 1,194.9 1.92 23.00 34.50 9.51
300 1 5 / 8 MA7200509 Neoprene 701.4 1.12 13.50 20.20 7.41 MA0538019a Urethane 1,052.1 1.68 20.20 30.30 10.63 MA7600551 Hytrel 2,104.2 3.36 40.40 60.60 11.65
400 1 7 / 8 MA9600139 Neoprene 1,056.3 1.69 20.30 30.40 8.93 MA9853544a Urethane 1,584.5 2.50 30.40 45.60 14.31 MA5760615 Hytrel 3,168.9 5.10 60.80 91.30 15.77
500 2 3 / 8 MA1550024 Neoprene 2,194.8 3.50 42.10 63.20 10.54 MA6170194a Urethane 3,292.2 5.30 63.20 94.80 22.68 MA9370802 Hytrel 6,584.4 10.50 126.40 189.60 19.95 a Urethane tends to soften in higher temperatures and humid conditions.
Coupling Size
Bore X Key
(in) Order No. Mfr. No. Net Price
5/8 X 5/32 MA4400425 M30002005 $22.68
3/4 X 3/16 MA2114061 M30002406 22.68
7/8 X 3/16 MA9902151 M30002806 22.68
7/8 X 1/4 MA3863857 M30002808 22.68
1 X 3/16 MA4440078 M30010006 22.68
1 X 1/4 MA7920726 M30010008 22.68
1 1/8 X 1/4 MA9909597 M30010408 22.68
1 3/16 X 1/4 MA4400082 M30010608 22.68
1 1/4 X 1/4 MA1330473 M30010808 22.68
1 1/4 X 5/16 MA7689860 M30010810 22.68
1 3/8 X 5/16 MA4401061 M30011210 22.68
1 3/8 X 3/8 MA1174520 M30011212 22.68
1 7/16 X 3/8 MA1069358 M30011412 22.68
1 1/2 X 3/8 MA0551655 M30011612 22.68
1 5/8 X 3/8 MA3863860 M30012012 22.68
3/4 X 3/16 MA2552157 M40002406 31.26
7/8 X 3/16 MA3050547 M40002806 31.26
1 X 3/16 MA1077060 M40010006 31.26
1 X 1/4 MA9463721 M40010008 31.26
1 1/8 X 1/4 MA6415600 M40010408 31.26
1 1/4 X 1/4 MA5664071 M40010808 31.26
1 1/4 X 5/16 MA9760278 M40010810 31.26
1 3/8 X 5/16 MA2110355 M40011210 31.26
1 7/16 X 3/8 MA1876639 M40011412 31.26
1 1/2 X 5/16 MA4400110 M40011610 31.26
1 1/2 X 3/8 MA0210695 M40011612 31.26
1 5/8 X 3/8 MA0235791 M40012012 31.26
1 3/4 X 3/8 MA1318568 M40012412 31.26
1 3/4 X 7/16 MA0216708 M40012414 31.26
1 7/8 X 1/2 MA9463719 M40012816 31.26
1 3/4 X 7/16 MA9909217 M50012414 43.55
1 7/8 X 1/2 MA2531057 M50012816 43.55
1 15/16 X 1/2 MA4400139 M50013016 43.55
2 X 1/2 MA3239891 M50020016 43.55
2 1/8 X 1/2 MA6478314 M50020416 43.55
2 1/4 X 1/2 MA4400342 M50020816 43.55
2 3/8 X 5/8 MA9536453 M50021220 43.55
APC09_CH10_SEC3_FINAL_955-980.in977 977APC09_CH10_SEC3_FINAL_955-980.in977 977 3/26/2009 2:06:20 PM3/26/2009 2:06:20 PM
HPU Item #06.2-06.3 Hydraulic Power Unit - Item #06.2-06.3Hydraulic Power Unit - Item #06.2-06.3
8-348-34
Premium Flexible Drive Couplings magnaloy coupling company 501 Commerce Drive Alpena, MI 49707 989 356-2186 A Division of Douville Johnston Corporation Fax: 989 354-4190 http://www.magnaloy.com
Magnaloy is the original lightweight, heavy-duty flexible drive coupling. Light weight magnesium construction makes Magnaloy couplings 76% lighter than cast iron and 36% lighter than aluminum units... and they’re stronger than either!
The benefits are many... Reduced loads on bearings, shafts and pumps, for longer component life. Easier handling and installation. Rust proof and corrosion resistant.
Magnaloy’s close machining tolerances (TIR of .002”) assures vibration-free operation and easy, accurate alignment without need for special tools. Solid magnesium alloy permanent mold castings are heat treated and offer the highest strength-to-weight ratio available.
Coupling Model
Maximum Bore
Wr2 lb-ft2 Insert
Number
Rated Torque lb-in
Torsional Rigidity lb-in/Deg
Horse Power Rating @ rpm rpm rpm
100 1 1/8 0.0046 170N 170U 170H
340.7 511.0 1,022.1
0.55 0.82 1.65
6.5 9.8 19.8
9.8 14.7 29.7
200 1 3/8 0.0068 270N 270U 270H
398.3 597.4 1,194.9
0.64 0.96 1.92
7.6 11.5 23.0
11.5 17.2 34.5
300 1 5/8 0.022 370N 370U 370H
701.4 1,052.1 2,104.2
1.12 1.68 3.36
13.5 20.2 40.4
20.2 30.3 60.6
400 1 7/8 0.031 470N 470U 470H
1,056.3 1,584.5 3,168.9
1.69 2.50 5.10
20.3 30.4 60.8
30.4 45.6 91.3
500 2 3/8 0.071 570N 570U 570H
2,194.8 3,292.2 6,584.4
1,571
3.50 5.30 10.50
42.1 63.2 146.4
63.2 94.8 189.6
600 2 5/8 0.16 670N 670U 670H
4,946.7 7,420.1 14,840.1
1,510 2,960
7.90 11.90 23.70
94.9 142.5 284.9
142.5 213.7 427.4
700 2 7/8 0.34 770N 770U 770H
11,639.8 17,459.7 29,099.5
1,805 2,104 5,960
18.60 27.90 46.50
223.5 335.2 558.8
335.2 502.8 838.0
800 3 7/8 0.95 870N 870U 870H
21,889.4 32,834.1 47,062.2
3,680
11,950
35.00 52.50 75.20
420.3 630.4 903.0
630.4 945.6 1,354.5
900 4 3/4 4.20 970N 970U
47,842.3 71,763.5
8,428
76.50 114.80
918.6 1,377.9
1,377.9 2,066.8
Coupling Performance Specifications
HPU Item #06.4Hydraulic Power Unit - Item #06.4Hydraulic Power Unit - Item #06.4
8-358-35
HPU Item #08 Hydraulic Power Unit - Item #08 - CXJA-XANHydraulic Power Unit - Item #08 - CXJA-XAN
8-368-36
HPU Item #09 Hydraulic Power Unit - Item #09 - RPGC-LANHydraulic Power Unit - Item #09 - RPGC-LAN
8-378-37
50P Series High Pressure Filters
HPU Item #11 Hydraulic Power Unit - Item #11 - 50P110QM50XX1Hydraulic Power Unit - Item #11 - 50P110QM50XX1
8-428-42
Applications
Applications for 50P series fi lters
- Automotive specifi ed equipment
- Hydrostatic transmission circuits
- Servo and proportional controls
- Offshore drilling rigs
- Mining equipment
- Power units
The design objective for all Parker fi lters is to achieve a sensible balance between cost and performance.
We use state of the art techno1ogy to arrive at innovative yet practical designs. Designs which are cost effective for OEM’s and users alike.
The 50P series allows you to customize each fi lter to closely match your needs. Choose the options which best fi t your application. No need to waste money on features you don’t need.
The 50P series fi lters are base mounted, which provides several possible advan tages. The bowl up mounting makes servicing the elements quick and easy. Simply remove the top cover to access the element. A drain port is provided to allow oil be removed from fi lter prior to element servicing. This design reduces the possibility of oil spillage and injury to maintenance personnel.
The 50P series has optional manifold porting for space saving design that re duces the number of fi ttings and potential leak points. The porting is also designed to match the installation of many other manufacturers. Most important, the 50P series meets the SAE HF4 automotive standard.
Vent Plug
- Purge all air from fi lter assembly
- Improves system performance
Bowl
- Single or double lengthHead
- Ductile iron construction- SAE or manifold ports
- Meets SAE HF4 automotive specifi cation
Drain Plug (not visible)
- Drain oil for easy service
Indicators
- Visual or electrical/visual
- Several connector options
Cover
- Durable ductile iron
- Top service elements
- No oil spills during service
Bypass (not visible)
- Cartridge style
- Precision matched assemblies
HPU Item #11
8-438-43
Features
O-Ring Seal
- Positive sealing for optimum ele ment effi ciency
Plastic End Caps
- Excellent corrosion pro tection
- Laser marked for clear long lasting identifi cation
Microglass III Media
- Multi-layer for high capacity and high effi ciency
- Four different micron sizes available
- Wire reinforced to prevent pleat bunching
Spiral Support Cylinders (Not Visible)
- High strength consistent support
- Continuous length eliminates leak points and increases surface area
Meets SAE HF4 specifi caton for automotive uses
Feature Advantage Benefi t
• Base mounted fi lter • No brackets required for installation • Reduced installation costs
• Top access cover • Remove element from top • No oil mess
• Lighter then removing entire bowl
• Visual and electrical indicators • Know exactly when to service elements
• Drain port • Drain all oil from assembly prior • Eliminates cross contamination to servicing
• Vent port • Purges all trapped air in fi lter • Get the maximum performance from elements
• Prevents a “spongy” system
• Multipass tested elements • Element performance backed • Elements selected will have (per ANSI/NFPA T3.10.8.8 R1-1990) by recognized test standards consistent performance levels
• Microglass III elements • Multi-layer media • High capacity with high effi ciency
• Wire reinforced pleats • No performance loss from pleat bunching
HPU Item #11
8-448-44
50PR Reverse Flow Filter
The 50PR was designed specifi cally for hydrostatic transmission loops because of it’s capability to handle reverse fl ow.
Closed circuit HSTs frequently reverse direction causing fl ow to reverse in the fl uid lines. Pressure fi lters installed between pump and motor must be able to handle reverse fl ow without having contaminant washed off of the elements and back into the system.
To prevent such an occurrence, the fi lters require the use of internal check valves to direct the fl ow through the element in one direction and around the element in the other. Parker’s internal check valve design minimizes additional pressure loss and eliminates the cost associated with external valves and fi ttings. Also the inter nal design keeps the envelope dimensions of the fi lter to aminimum as can be seen on the installation drawing.
Sizing 50PR Filter Assemblies
To accurately determine the total pressure loss that will be seen when used in your system, the following steps should be taken.
1. Examine the “Flow vs. Pressure” curve below. Find the pressure drop for the maximum system fl ow on the forward fl ow curve. Record this value as “housing with check valve pressure loss.”
2. Examine the appropriate pressure loss curve for the media and bowl length combination. These curves are found in the Element Performance Data section.
3. Find the pressure drop for the maximum fl ow rate through the fi lter and record this value as “element pressure loss.”
4. Find the empty housing pressure drop for the maximum fl ow rate through the fi lter and record this value as “empty housing pressure loss.”
5. Add the values obtained in steps 1 and 3, then subtract out the value from step 4. The resultant pressure loss should not exceed 1/3 of the bypass valve or indicator you intend to select. If this ratio exceeds 1/3, then a double length housing or other media grade may need to be considered.
Contact the Hydraulic Filter Division if there is any doubt as to the total pressure loss you have calculated.
Bypass Valve
50PR Schematic
RFC
Typical FLow/Pressure Curves For 50 PR 1.75
1.5
1.25
0.75
0.5
0.25
(B
AR
D
IF
F.
P R
ES
S.
(P
SI
0 10 20 30 40 50 60 70 80 90 100
(GPM) FLOW (LPM)
0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375
200 SUS200 SUS200 SUS
FORWARD FLOW (R
.F.C.V. O
NLY)
FORWARD FLOW (R
.F.C.V. O
NLY)
FORWARD FLOW (R
.F.C.V. O
NLY)
REVERSE FLOW (TOTAL)
REVERSE FLOW (TOTAL)
REVERSE FLOW (TOTAL)REVERSE FLOW CHECK VALVEREVERSE FLOW CHECK VALVEREVERSE FLOW CHECK VALVE
HPU Item #11
8-458-45
50P-1 Element Performance
Efficiency % Efficiency
Beta Rating
10000
99.9
99.5 99.0100
2 50.0
95.0
Micron Size (c)
2Q
10Q
20Q
2Q
10Q
20Q
2Q
10Q
20Q
5Q5Q
0 4 8 12 16 20
LPM
02Q
20Q10Q
PS
ID
GPM
1.5
1.0
0.5
0.0
B A
R
150SUS
05Q
0 50 100 150 200 250 300 350
0 20 40 60 80 100
LPM
PS
ID
GPM
1.5
1.0
0.5
0.0
B
AR
150SUS
Empty Housing
0 50 100 150 200 250 300 350
0 20 40 60 80 100
Flow vs. Pressure Loss
Capacity grams
PSID BAR
Capacity
5Q
2Q
20Q
10Q
0 20 40 60 80 100 120
Results typical from Multi-pass tests run per test standard ISO 16889 @ 50 gpm to 100 psid terminal - 10 mg/L BUGL
Refer to Appendix on pages 265-266 for relationship to test standard ISO 4572.
HPU Item #11
8-468-46
50P-2 Element Performance
Efficiency % Efficiency
Beta Rating
10000
99.9
99.5 99.0100
2 50.0
95.0
Micron Size (c)
2Q
10Q
20Q
2Q
10Q
20Q
2Q
10Q
20Q
5Q5Q
0 4 8 12 16 20
02Q
20Q
10Q
05Q
LPM
PS
ID
GPM
1.5
1.0
0.5
0.0
B
AR
150SUS
0 100 200 300 400 500
0 30 60 90 120 150
LPM
1.0
0.5
0.0
0 100 200 300 400 500
0 30 60 90 120 150
Capacity grams
PSID BAR
Capacity
20Q 10Q
2Q 5Q
0 50 100 150 200 250 300
Flow vs. Pressure Loss
Results typical from Multi-pass tests run per test standard ISO 16889 @ 80 gpm to 100 psid terminal - 10 mg/L BUGL
Refer to Appendix on pages 265-266 for relationship to test standard ISO 4572.
HPU Item #11
8-478-47
50P-3 Element Performance
Efficiency % Efficiency
Beta Rating
10000
99.9
99.5
99.0 100
2 50.0
95.0
Micron Size (c)
0 4 8 12 16 20
2Q2Q2Q 5Q5Q5Q
20Q20Q20Q
10Q10Q10Q
LPM
02Q
20Q
10Q
1.0
0.5
0.0
B A
R
05Q
0 100 200 300 400 500
0 30 60 90 120 150
LPM
1.0
0.5
0.0
0 20 40 60 80 100
0 100 200 300 400 500
Empty Housing
Flow vs. Pressure Loss
Capacity grams
PSID BAR
Capacity
5Q
2Q
20Q
10Q
0 50 100 150 200 250 300 350 400
Results typical from Multi-pass tests run per test standard ISO 16889 @ 80 gpm to 100 psid terminal - 10 mg/L BUGL
Refer to Appendix on pages 265-266 for relationship to test standard ISO 4572.
HPU Item #11
8-488-48
Specifi cations
162.6 6.40
68.1
SAE-5 BLEED
PORT TORQUE
20-25 FT LBS.
TORQUE
45-50 FT LBS.
TORQUE
115-130 FT LBS.
OPTIONAL
FLANGE
OUTLET
158.8 6.25
161.8 6.37
“YY” “PP”
2.68
Pressure Ratings:
Maximum Allowable Operating Pressure (MAOP): 5000 psi (344.8 bar) Rated Fatigue Pressure: 3500 psi (241.4 bar) Design Safety Factor: 3:1
Element Collapse Rating:
150 psid (10.2 bar) standard 2000 psid (138 bar) high collapse “H” option
Operating Temperatures:
Buna: -40oF (-40oC) to 225oF (107oC) Fluorocarbon: -15oF (-26oC) to 275oF (135oC)
Filter Materials:
Head (base) and Cover: ductile iron Bowl: seamless steel tube
Indicators:
Visual 3 band (clean, change element, bypass) Electrical: visual as above plus electrical switch with wire leads or connection as selected.
5A @ 240VAC
3A @ 28VDC
SPDT
Color Coding:
White (normally closed) Red (normally open) Black (common)
Shipping Weights (approximate):
50P-1: 56 lb. (25.4 kg) 50P-2: 77 lb. (34.9 kg) 50P-3: 95 lbs. (43.0 kg) 50PR-1: 59 lb. (26.8 kg) 50PR-2: 80 lb. (36.3 kg)
7.9
127.0 5.00
34.9
42.8
1.95
57.2
114.3
98.0 3.86
4.50
14.3 .563
2.25
.0775
1.685
1.375
.31
50.8 2.00
63.5 2.50
Linear Measure: millimeter inch
34.8 1.37
92.2 3.63
12.7 .50
ELEMENT REMOVAL
CLEARANCE
Z
SAE-5
DRAIN PORT
OPTIONAL
RIGHT HAND
INDICATOR
1½” SAE-24 PORTS
OUTLET (2-128 O-RING)
INLET
(2-128 O-RING)
MOUNTING HOLES
DIA. THRU
DEEP
DIA. C BORE
X
22.4 .88
79.4 3.125
39.6 1.56
34.8 1.37
38.1 1.50
18.3 .72
36.5 1.437
12.7 .50
5/8”-11 UNC-2B
DIA. THRU
D
Drawings are for reference only.
Contact factory for current version.
387.1
15.24
404.6
15.93
622.8
24.52
640.3
25.21
254.0
10.00
254.0
10.00
508.0
20.00
508.0
20.00
X
Z
50P-1 50PR-1 50P-2 50PR-2 50P-3Dimensions= mm/inches
850.4
33.48
760.2
30.00
387.1 404.6 622.8 640.3
HPU Item #11
8-498-49
Parts List and Service Instructions
Element Service Instructions
When servicing the 50P fi lter, use the following procedure.
A. Stop the system’s power unit.
B. Relieve any pressure in the fi lter or line.
C. If desired, oil can be drained from fi lter housing by removing the drain port plug located in the head.
D. Rotate the cover counter clockwise and remove.
E. Remove element from housing.
F Place new, clean element into housing centering element over locator.
G. Inspect cover o-ring and replace if necessary
H. Apply cover to fi lter and tighten to 45-50 ft. lbs.
I. Replace drain plug and tighten 20-25 ft. lbs.
Parts List
Index Description Part Number 50P/PR
1 Head Assembly Consult Factory
2 Bowl Consult Factory
3 Cover 926655
4 Cover O-Ring
Buna N92246 Fluorocarbon V92246
5 Vent Plug 935466
Buna O-ring N93905 Fluorocarbon O-ring V93905
6 Element See model code page
7 Drain Plug 928364
Buna O-ring N93905 Fluorocarbon O-ring V93905
8 Bypass Valve
(50PR valve is not serviceable)
50 psi 924189
No bypass, 50 psi indicator 924192
90 psi 927399
No bypass, 90 psi indicator 930683
Indicator Kits
Mechanical (left side) 931916
Mechanical (right side) 931924
Electrical (wire leads) 925337
Electrical (3-pin Brad Harrison style) 926482
Electrical (DIN 43650 connection) 929362
O-Ring, Manifold Port
Buna N92128
Fluorocarbon V92128
Note: Consult factory for EPR compatible part numbers
HPU Item #11
8-508-50
How to Order
50P/50PR Replacement Elements (Fluorocarbon)
Standard Collapse High Collapse
Media Single Double Triple Media Single Double Triple
20Q 931018Q 931020Q 933489Q 20QH 930438Q 931490Q 936449Q
10Q 932670Q 932679Q 933488Q 10QH 932676Q 932685Q 936448Q
05Q 932669Q 932678Q 933487Q 05QH 932675Q 932684Q 936447Q
02Q 932668Q 932677Q 933486Q 02QH 932674Q 932683Q 936446Q
Please note the bolded options refl ect standard options with a reduced lead-time.
Consult factory on all other lead-time options.
BOX 6: Bypass and Indicator Setting
BOX 2: Basic Assembly
Symbol Description
50P 5000 PSI (MAOP)
50PR* Reverse fl ow hydrostatic version
BOX 3: Length
Symbol Description
1 Single
2 Double
3 Triple
Symbol Pressure Setting
35 35 psid 50 50 psid 90 90 psid
BOX 7: Ports
Symbol Description
PP SAE-24 straight thread
YY SAE 1½” fl ange face (J518) XX 13/8” manifold ports on bottom of head
BOX 8: Options
Symbol Description
1 None
11 Blocked bypass
BOX 1: Seals
Symbol Description
None Buna
F3 Fluorocarbon
E8 EPR
Symbol Description
P Port plugged
PL Port plugged, left side
M Visual indicator ML Visual indicator, left side E Electrical indicator with wire leads and conduit connection
EL Electrical indicator with wire leads and conduit connection, left side
D Electrical indicator w/ ANSI/B.93.55M 3-pin Brad Harrison style connection
DL Electrical indicator w/ ANSI/B.93.55M 3-pin Brad Harrison style connection, left side
BOX 5: Indicators
BOX 4: Element Media
Symbol Description
20Q Microglass III 10Q Microglass III 05Q Microglass III 02Q Microglass III Note: For high collapse 2000 psid rated elements, add “H” behind Q.
Note: Left side is on viewer’s left when looking into inlet port.
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8
*Note: Not available in triple length. Must select “1” or “2” in BOX 3
F3 50P 1 10Q DL 90 PP 1
HPU Item #11
8-518-51
Model: RSHC-LAN Capacity: 60 gpm (240 L/min.)
Pilot operated, balanced piston sequence valve
Pilot-operated, balanced piston sequence valves will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3). These valves are insensitive to back pressure at port 2 (sequence), up to the valve setting. They may be used to regulate pressure in place of 2-port relief valves if there is pressure in the return line.
Technical Data
U.S. Units Metric Units
Cavity T-17A
Capacity 60 gpm 240 L/min.
Control Pilot Flow 15 - 20 in³/min. 0,25 - 0,33 L/min.
Factory Pressure Settings Established at 4 gpm 15 L/min.
Maximum Operating Pressure 5000 psi 350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 4 in³/min.@1000 psi 65 cc/min.@70 bar
Response Time - Typical 10 ms
Series (from Cavity) Series 3
Adjustment - Number of Clockwise Turns to Increase Setting 5
Valve Hex Size 1 1/4 in. 31,8 mm
Valve Installation Torque 150 - 160 lbf ft 200 - 215 Nm
Adjustment Screw Internal Hex Size 5/32 in. 4 mm
Adjustment Locknut/Cap Hex Size 9/16 in. 15 mm
Adjustment Nut Torque 80 - 90 lbf in. 9 - 10 Nm
Model Weight 1.50 lb 0,70 kg
Seal Kits - Cartridge Buna: 990-017-007
Seal Kits - Cartridge Viton: 990-017-006
Control Adjustment Range Seal
Material
L Standard Screw Adjustment
A 100 - 3000 psi (7 - 210 bar), 1000 psi (70 bar) Standard Setting
N Buna-N http://www.sunhydraulics.com Date Created: 10/10/2011
Copyright © 2010-2011 Sun Hydraulics Corporation. All rights reserved.
HPU Item #12 Hydraulic Power Unit - Item #12 - RSJC-LBNHydraulic Power Unit - Item #12 - RSJC-LBN
8-528-52
Hydraulics K14
Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA
Catalog HY14-3000/US repcat-k.p65, dd, fn
Manatrol Volume Control Valves Series TPC
K
Series TPC valves are pressure compensated and are insensitive to variations in oil temperature. They can maintain selected flow to within ±5% of setting over a pressure range from 100 to 3000 psi (7 to 210 Bar).
These valves are ideal for use on meter-in/meter-out or bleed-off circuits. Their insensitivity to oil temperature change allows flow to hold constant throughout wide fluctuations. Minimum pressure differential between inlet and outlet ports must be 100 psi (7 Bar) for Model TPC600, and 150 psi (10.5 Bar) for Model TPC1200.
Optional reverse-flow check valves are available on Models TPCC600 and TPCC1200; check-valve cracking pressure is 5 psi (0.4 Bar).
Optional lunge control to limit compensator piston travel is available on Model TPC600; this prepositions the compen-sator piston to minimize actuator lunge.
Maximum operating pressure, all models: 3000 psi (210 Bar).
Quick Reference Data Chart
Needle Flow Chart
Manatrol Series TPC Temperature and Pressure Compensated Flow Control Valves
Hydraulic Power Unit - Item #13 - TPCS600S3ALHydraulic Power Unit - Item #13 - TPCS600S3AL
8-538-53
Hydraulics K15
Hydraulic Valve Division Elyria, Ohio 44035 USA
Catalog HY14-3000/US repcat-k.p65, dd, fn
Manatrol Volume Control Valves Series TPC
K
Dimensions Model TPC600S In-line mounted, pressure-compensated, temperature-insensitive flow control valve
8-548-54
Hydraulics K16
Hydraulic Valve Division Elyria, Ohio 44035 USA
Catalog HY14-3000/US repcat-k.p65, dd, fn
Manatrol Volume Control Valves Series TPC
K
Dimensions Model TPC1200S28 In-line mounted, pressure-compensated, temperature-insensitive flow control valve.
8-558-55
Hydraulics K17
Hydraulic Valve Division Elyria, Ohio 44035 USA
Catalog HY14-3000/US repcat-k.p65, dd, fn
Manatrol Volume Control Valves Series TPC
K
Dimensions Model TPCS600S Manifold-mounted, pressure-compensated, temperature-insensitive flow control valve.
8-568-56
Hydraulics K18
Hydraulic Valve Division Elyria, Ohio 44035 USA
Catalog HY14-3000/US repcat-k.p65, dd, fn
Manatrol Volume Control Valves Series TPC
K
Dimensions Model TPCC600S In-line mounted, pressure-compensated, temperature-insensitive flow control valve with check.
8-578-57
Hydraulics K19
Hydraulic Valve Division Elyria, Ohio 44035 USA
Catalog HY14-3000/US repcat-k.p65, dd, fn
Manatrol Volume Control Valves Series TPC
K
Dimensions Model TPCC1200S-28 In-line mounted, pressure-compensated, temperature-insensitive flow control valve.
8-588-58
Hydraulics K20
Hydraulic Valve Division Elyria, Ohio 44035 USA
Catalog HY14-3000/US repcat-k.p65, dd, fn
Manatrol Volume Control Valves Series TPC
Sub Plate Dimensions
Reference Data Only (Subplates are not available)
K
Subplate Dimensions Use bolt kit BK-07 for mounting series TPCS600S valve on this subplate
8-598-59
Hydraulics K21
Hydraulic Valve Division Elyria, Ohio 44035 USA
Catalog HY14-3000/US repcat-k.p65, dd, fn
Manatrol Volume Control Valves Series TPC
Accessories
Bolt Kits
TPCS600
Bolt Kit Bolt specification Bolt torque
No. BK07 5/16" - 18 x 1" 19 ft. lb.
Omit Nitrile
V Fluorocarbon
K
Ordering Information How to order Series TPC Flow Control Valves Example: “TPCC600S02ALV” means Series TPC Valve, with reverse-flow check valve, in-line mounting size 3/8”, flow range of 5 to 50 CIPM, lunge control option, Fluorocarbon seals.
8-608-60
FLO
W
, N
EED
LE &
C
H
EC
K
VA
LVES
H
YD
R
A U
LIC
B
A
LL VA
LVES
W
ELD
C
O U
PLIN
G
S
FLA
N G
ES
Anchor Fluid Power • 5555 Fair Lane, Cincinnati, OH 45227 • (Offi ce)1-866-FLANGES (Fax) 513-527-4449 www.anchorfl uidpower.com • sales@anchorfl uidpower.com
LV2B Series / 1000 WOG Stainless Steel
• All stainless steel construction
• Locking handles standard
• Ideal for suction, pressure and return lines
• Available in NPT & SAE threads
• Mounting holes standard on SAE #16 - #32
• Mounting holes optional on all other valves up to 2”
FF
EEEE
DD
FRONT MOUNTING HOLESFRONT MOUNTING HOLES
ON 2" SIZE ONLYON 2" SIZE ONLY
SHOWN WITH OPTIONAL MOUNTING HOLESSHOWN WITH OPTIONAL MOUNTING HOLES
BB
GG
CC
AA
COMPONENT MATERIALS
COMPONENT MATERIAL
VALVE BODY ASTM A351
GR CF8M
TAILPIECE ASTM A351
GR CF8M
BALL ASTM A351
GR CF8M
STEM 316 1
BALL SEAT PTFE 2
STEM SEAT PTFE 1
STEM PACKING PTFE 1
STEM GLAND 304 1
HANDLE 304 1
STEM LOCK
WASHER
304 1
STEM NUT 304 1
HANDLE
SLEEVE
VINYL 1
LOCK 304 1
Model Code: LV2B N 1/2” -2T -MH
Thread type (N-NPT; S-SAE) Optional Mounting Holes Thread size (Ex. N1/2”; S#8)
LV2B SERIES - NPT
SIZE A B C D E F
UNC
G
1/4” .36 2.13 2.13 1.12 .49 10-24 4.33
3/8” .50 2.13 2.17 1.12 .49 10-24 4.33
1/2” .59 2.24 2.28 1.12 .49 10-24 4.53
3/4” .79 2.68 2.40 1.12 .49 10-24 4.53
1” .98 3.15 3.03 1.38 .91 1/4-20 5.04
1-1/4” 1.26 3.58 3.19 1.48 1.00 1/4-20 5.04
1-1/2” 1.50 4.06 3.54 1.48 1.00 1/4-20 6.10
2” 1.97 4.88 4.25 1.50 1.00 1/4-20 6.10
2-1/2” 2.56 6.30 5.20 N/A N/A N/A 9.06
3” 3.15 7.28 5.71 N/A N/A N/A 9.06
LV2B SERIES - SAE
SIZE A B C D E F
UNC
G
1/4” .35 2.40 2.13 1.12 .49 10-24 4.33
3/8” .47 2.40 2.17 1.12 .49 10-24 4.33
1/2” .59 2.52 2.28 1.12 .49 10-24 4.53
3/4” .79 3.23 2.40 1.12 .49 10-24 4.53
1” .98 3.62 3.03 1.38 .91 1/4-20 5.04
1-1/4” 1.26 3.96 3.19 1.48 1.00 1/4-20 5.04
1-1/2” 1.50 4.23 3.54 1.48 1.00 1/4-20 6.10
2” 1.97 4.90 4.25 1.50 1.00 1/4-20 6.10
HPU Item #14, 18, 27
Hydraulic Power Unit - Item #14, 18, 27Hydraulic Power Unit - Item #14, 18, 27
8-618-61
15/40/80CN Series Medium Pressure Filters
HPU Item #15, 28 Hydraulic Power Unit - Item #15, 28Hydraulic Power Unit - Item #15, 28
8-628-62
Parker Hannifin Corporation Hydraulic Filter Division Metamora, OH
Applications for CN series Filters
■ Compressor Lube Oil
■ Off-line Filter Loops
■ Machine Tools (Automotive Standard)
■ Hydrostatic Drive Charge Pumps
■ Mobile Equipment
■ Pilot Lines For Servo Controls
■ Oil Patch Drilling Equipment
■ Injection Molding
This partial list of applications for Parker “CN” series filters has a common factor, the need for an economical, medium pressure range filter with excellent fatigue pressure ratings. Prior to the availability of the “CN” filter, applications such as those listed were restricted by limitations of a spin-on can, or forced into the higher cost range of high pressure filters.
The “CN” series fills this gap, and now with the newly increased fatigue rating from 550 to 800 psi, the applications are expanded.
Features Advantages Benefits
· 800 psi fatigue rating · Ability to provide reliable service · Reduced downtime due to premature (eight times that of a spin-on) under tough cyclic operating conditions filter failures
· Can be utilized in applications where high · Reduced costs, better “fit” pressure filters may have been only option for the application
· Diametral (side) seal between · Proven reliability in cyclic applications · No downtime, no leaks head and bowl · Reduced importance of bowl torque · Performs with “real world” service
· Dust Seal · Prevents contamination from building · Easier service, no galling up on bowl / head threads
· 40CN-2 meets automotive HF3 standard · Automotive industry acceptance · Satisfies specifications without need
· 15CN meets automotive HF2 standard for further testing and/or approval
· Cast aluminum head · Low profile, lightweight and durable · Less weight, smaller envelop and cleaner appearance
· Standard Ecoglass III elements · Multi-layered design produced high · Great performance value capacity and efficiency · Reliable performance throughout
· Reduces pleat bunching, element life keeps performance consistent · Reduces downtime, maximizes element life
· Complete performance data disclosure · All pertinent information is provided in · No hidden deficiencies an easy-to-compare format · Easy selection of proper filtration
· Visual, electrical or electrical/visual · Check element condition at a glance · Optimize element life, prevent bypassing indicators available · Right style for the application · Matches your system electrical connections
Ecoglass III Replacement Elements Ecoglass III represents the merging of high performance filtration technology with environmentally conscious engineering. The Ecoglass III line of replacement elements feature 100% non-metallic construction. The design reduces solid waste and minimizes disposal costs for industry. The non-metallic construction means lightweight elements (60% less weight) for easier servicing.
The Ecoglass III elements utilize the same proprietary media design as our Microglass III line of replacement elements.
With Ecoglass III, a reusable core is installed into the filter housing and remains in service throughout the life of the assembly.
HPU Item #15, 28
8-638-63
Parker Hannifin Corporation Hydraulic Filter Division Metamora, OH69
Features
Ports
■ SAE, NPT or flange face (80CN) provides mounting flexibility.
Diametral (side) Seal
Dust Seal
■ Protects head and bowl threads from external contamination buildup.
Element Assembly
■ High efficiency (Bx>200), high capacity Ecoglass III media with it’s multi-layered design is unequalled in performance.
Element Condition Indicators
■ Available in visual or electrical, with a choice of several power connections (E3 shown).
Head
■ Cast aluminum is rugged with small profile for easy mounting.
Bypass
■ Cartridge style bypass has good sealing characteristics and low hysteresis. Choice of two settings to match application needs.
Bowl
■ Anodized aluminum is lightweight and corrosion resistant. Friction grip tape prevents slipping when rotating the bowl during service.
Drain Port (optional)
■ Optional drain port allows for easy element servicing.
HPU Item #15, 28
8-648-64
Parker Hannifin Corporation Hydraulic Filter Division Metamora, OH
15CN-1 Element Performance
PS
ID
1.5
1.0
0.5
0.0
GPM
02Q
20Q
10Q
05Q
B
AR
LPM
150SUS
0 10 20 30 40 50 60 70
0 5 10 15 20
PS
ID
1.5
1.0
0.5
0.0
GPM
B
AR
LPM
150SUS
EMPTY HOUSING
¾” Nominal Port Size
1” Nominal Port Size
0 5 10 15 20
0 10 20 30 40 50 60 70
Flow vs. Pressure Loss
Efficiency % Efficiency
Beta Rating
10000
99.9
99.5 99.0100
2 50.0
95.0
Micron Size (c)
2Q
10Q
20Q
5Q
0 4 8 12 16 20
PSID
Capacity
20Q 10Q 5Q 2Q
0 1 2 3 4 5 6 7
Capacity grams
BAR
Results typical from Multi-pass tests run per test standard ISO 16889 @ 10 gpm to 100 psid terminal - 10 mg/L BUGL Refer to Appendix on pages 227-228 for relationship to test standard ISO 4572.
HPU Item #15, 28
8-658-65
Parker Hannifin Corporation Hydraulic Filter Division Metamora, OH71
PS
ID
GPM
02Q
20Q
05Q
B
AR
LPM
150 SUS
1.5
1.0
0.5
0.0
10Q
0 20 40 60 80
0 5 10 15 20 25
PS
ID
GPM
B
AR
LPM
150 SUS
1.5
1.0
0.5
0.0
EMPTY HOUSING
¾” N ominal P ort Size
1” Nominal Port Size
0 20 40 60 80
0 5 10 15 20 25
15CN-2 Element Performance
Flow vs. Pressure Loss
Results typical from Multi-pass tests run per test standard ISO 16889 @ 15 gpm to 100 psid terminal - 10 mg/L BUGL Refer to Appendix on pages 227-228 for relationship to test standard ISO 4572.
Efficiency % Efficiency
Beta Rating
10000
99.9
99.5 99.0100
2 50.0
95.0
Micron Size (c)
2Q
10Q
20Q
5Q
0 4 8 12 16 20
PSID
Capacity
20Q
2Q 5Q
10Q
0 5 10 15 20
Capacity grams
BAR
HPU Item #15, 28
8-668-66
Parker Hannifin Corporation Hydraulic Filter Division Metamora, OH
40CN-1 Element Performance
PS
ID
GPM
02Q
20Q
05Q
B
AR
LPM
150 SUS
1.5
1.0
0.5
0.0
10Q
0 20 40 60 80 100
0 50 100 150 200 250 300 350
Efficiency % Efficiency
Beta Rating
10000
99.9
99.5 99.0100
2 50.0
95.0
Micron Size (c)
2Q
10Q
20Q
5Q
0 4 8 12 16 20
PS
ID
GPM
B
AR
LPM
150 SUS
1.5
1.0
0.5
0.0
EMPTY HOUSING
1½” Nominal P ort S ize
0 50 100 150 200 250 300 350
0 20 40 60 80 100
1” N om in al P or t S ize
PSID
Capacity
0 10 20 30 40
Capacity grams
2Q 5Q
10Q 20Q
BAR
Results typical from Multi-pass tests run per test standard ISO 16889 @ 15 gpm to 100 psid terminal - 10 mg/L BUGL Refer to Appendix on pages 227-228 for relationship to test standard ISO 4572.
Flow vs. Pressure Loss
HPU Item #15, 28
8-678-67
Parker Hannifin Corporation Hydraulic Filter Division Metamora, OH73
40CN-2 Element Performance
PS
ID
GPM
02Q
20Q
05Q
B
AR
LPM
150 SUS
1.5
1.0
0.5
0.0
10Q
0 20 40 60 80 100
0 50 100 150 200 250 300 350
Efficiency % Efficiency
Beta Rating
10000
99.9
99.5 99.0100
2 50.0
95.0
Micron Size (c)
2Q
10Q
20Q
5Q
0 4 8 12 16 20
PS
ID
GPM
B
AR
LPM
150 SUS
1.5
1.0
0.5
0.0
EMPTY HOUSING
1½” N ominal P ort S ize
0 50 100 150 200 250 300 350
1” N om in al P or t S ize
0 20 40 60 80 100
PSID Capacity
0 10 20 30 40 50 60 70 Capacity grams
BAR
2Q
10Q 20Q
5Q
Results typical from Multi-pass tests run per test standard ISO 16889 @ 30 gpm to 100 psid terminal - 10 mg/L BUGL Refer to Appendix on pages 227-228 for relationship to test standard ISO 4572.
Flow vs. Pressure Loss
HPU Item #15, 28
8-688-68
Parker Hannifin Corporation Hydraulic Filter Division Metamora, OH
40CN-3 Element Performance
PSID BAR
Capacity
2Q
10Q 20Q
5Q
0 20 40 60 80 100 120
Capacity grams
Results typical from Multi-pass tests run per test standard ISO 16889 @ 45 gpm to 100 psid terminal - 10 mg/L BUGL Refer to Appendix on pages 227-228 for relationship to test standard ISO 4572.
Flow vs. Pressure Loss
HPU Item #15, 28
8-698-69
Parker Hannifin Corporation Hydraulic Filter Division Metamora, OH
80CN-1 Element Performance
Efficiency % Efficiency
Beta Rating
10000
99.9
99.5 99.0100
2 50.0
95.0
Micron Size (c)
2Q
10Q
20Q
5Q
0 4 8 12 16 20
PS
ID
GPM
02Q
20Q
05Q
B
AR
LPM
150 SUS
1.5
1.0
0.5
0.0
10Q
0 50 100 150 200 250 300 350
0 20 40 60 80 100
LPM
PS
ID
0.6
0.5
0.4
0.3
0.2
0.1
0.0
GPM
Empty Housing
B
AR
150 SUS
2” Nominal Port Size1½” Nominal Port Size
0 50 100 150 200 250 300 350
0 20 40 60 80 100
Results typical from Multi-pass tests run per test standard ISO 16889 @ 45 gpm to 100 psid terminal - 10 mg/L BUGL Refer to Appendix on pages 227-228 for relationship to test standard ISO 4572.
Flow vs. Pressure Loss
PSID
Capacity
2Q
10Q 20Q
5Q
0 20 40 60 80 100
Capacity grams
BAR
HPU Item #15, 28
8-708-70
Parker Hannifin Corporation Hydraulic Filter Division Metamora, OH
Efficiency % Efficiency
Beta Rating
10000
99.9
99.5 99.0100
2 50.0
95.0
Micron Size (c)
2Q
10Q
20Q
5Q
0 4 8 12 16 20
PS
ID
GPM
02Q
20Q
05Q
LPM
150 SUS
10Q
B
AR
1.5
1.0
0.5
0.0
0 100 200 300 400 500
0 30 60 90 120 150
PS
ID
GPM
LPM
150 SUS
1.5
1.0
0.5
0.0
0 100 200 300 400 500
0 30 60 90 120 150
1½” N ominal P ort Size
2” Nominal Port Size
PSID
Capacity
0 20 40 60 80 100 120 140
Capacity grams
BAR
20Q
2Q 5Q 10Q
80CN-2 Element Performance
Flow vs. Pressure Loss
Results typical from Multi-pass tests run per test standard ISO 16889 @ 70 gpm to 100 psid terminal - 10 mg/L BUGL Refer to Appendix on pages 227-228 for relationship to test standard ISO 4572.
HPU Item #15, 28
8-718-71
Parker Hannifin Corporation Hydraulic Filter Division Metamora, OH
Specifications: CN Series Pressure Ratings:
Maximum Allowable Operating Pressure (MAOP): 1000 psi (69 bar) Rated Fatigue Pressure: 800 psi (55.2 bar) Design Safety Factor: 2.5:1
Operating Temperatures:
Buna: -40oF (-40oC) to 225oF (107oC) Fluorocarbon: -15oF (-26oC) to 275oF (135oC)
Element Collapse Rating:
Standard: 150 psi (10.3 bar)
Materials:
Head and Bowl: Aluminum Indicators: Aluminum body, plastic connectors Bypass: Nylon
Element Condition Indicators:
Visual 360o green/red auto reset Electrical/Visual
5A @ 240VAC, 3A @ 28VDC
Electrical-Heavy Duty .25A(resistive) MAX 5 watts 12 to 28 VDC & 110 to 175 VAC Color code: White (common), Black (normally open), Blue (normally closed)
Weights (approximate):
Model Single length Double length 15CN 2.5 lb. (1.13 kg) 3.5 lb. (1.6 kg) 40CN 4.5 lb. (2.00 kg) 5.5 lb. (2.49 kg) 80CN 12.4 lb. (5.62 kg) 15.2 lb. (6.89 kg)
Element Removal Clearance
2.50 (63.5)
H
I
F
G
4 Mounting Holes 1/4”-20 UNC x 0.28 (7.1)
K
J
L
Torque 25-30 ft. lbs.
D
C
Torque 15 - 20 ft. lbs.
SAE - 4
Drain Plug
1.00 (25.4) Nominal Hex
E
Single Lengt h A
Double Lengt h B
M2, E2, E3-
2.38 (60.5)
H-3.31(84.1) H1-2.58 (65.5)
H
F
G
I
K
L
J
Torque 25 - 30 ft. lbs.
Element Removal Clearance
2.50 (63.5)
Torque 42 - 50 ft. lbs.
1.00 (25.4) Nominal Hex
SAE - 4
Drain Plug
E
C
D
Single Lengt h A
Double Lengt h B
4 Mounting Holes 5/16”-18 UNC x 0.50 (12.7)
M2, E2, E3-
2.38 (60.5)
H-3.31(84.1) H1-2.58 (65.5)
H
L
G
I
K
F
4 Mounting holes
5/16 - 18 UNC X 63 (16.0)
D
C
Torque 60-70 ft. lbs.
E
SAE- 4
Drain Plug
1.00 (25.4) Nominal Hex
Element Removal Clearance
2.50 (13.5)
Single Lengt h A
Double Lengt h B
M2, E2, E3-
3.06 (77.7)
H-3.93 (99.8) H1-3.20 (81.3)
J
15CN
A B C D E F G H I J K L
6.17(156.6) 9.87(250.7) 1.83(46.5) 1.09(25.4) 2.80(71.1) 3.38(85.9) 2.88(73.2) 3.25(82.6) 1.50(88.1) .90(22.9) 1.69(42.9) 1.44(36.6)
6.73(170.8) 10.33(262.4) 2.44(62.0) 1.28(32.6) 4.22(107.2) 5.00(127.0) 4.37(111.0) 4.80(121.9) 2.44(62.0) 1.25(31.8) 2.32(58.8) 2.37(60.2)
11.06(280.9) 15.81(401.6) 3.06(77.7) 1.95(49.5) 4.91(124.8) 6.25(158.7) 3.25(82.6) 5.96(151.4) 4.00(101.6) 1.62(41.1) 3.12(79.4) 1.63(41.3)
Dimensions are in(mm)
15CN
80CN
40CN
E2 E3
40CN 80CN
HPU Item #15, 28
8-728-72
Parker Hannifin Corporation Hydraulic Filter Division Metamora, OH
Element Service A. Stop the system’s power unit.
B. Relieve any system pressure in the filter line.
C. Drain the filter bowl if drain port option is provided.
D. Loosen and remove bowl.
E. Remove element by pulling downward with a slight twisting motion and discard.
F. Check bowl o-ring for damage and replace if necessary.
G. Lubricate element o-ring with system fluid and place on post in filter head.
H. Install bowl and tighten to specified torque.
15CN - 15-20 ft. lbs 40CN - 42-50 ft. lbs 80CN - 60-70 ft. lbs I. Confirm there are no leaks after powering the system.
2 3
Index Description 15CN 40CN 80CN
| 1 | Head | ||||||||||
| 3/4” | NPT | bypass/ | indicator | ready | 933865 | N/A | N/A | ||||
| 3/4” | NPT | no | bypass/ | no | indicator | 933877 | N/A | N/A | |||
| 3/4” | NPT | no | bypass/ | indicator | ready | 933869 | N/A | N/A | |||
| 3/4” | NPT | no | indicator/ | bypass | ready | 933873 | N/A | N/A | |||
| SAE-12 | bypass/ | indicator | ready | 933863 | N/A | N/A | |||||
| SAE-12 | no | bypass/ | no | indicator | 933875 | N/A | N/A |
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .