App_C_-_Network_Diagrams.pdf

PDF 2 MB Posted

Attached to
SCADA System
Solicitation number
W912P518T0003
Issued by

About this file

Appendix C

View the file

Other files

File Type Posted
PROPOSAL_DATA_SHEET.pdf PDF
W912P518T00030004.pdf PDF
W912P518T00030003.pdf PDF
SCADA_TSpecs_Amend3.pdf PDF
W912P518T00030002.pdf PDF
W912P518T00030001.pdf PDF
Sign_In_Sheet.pdf PDF
App_A_-_SCADA_Points.pdf PDF
Site_Visit_Request_Form.pdf PDF
Foreign_National_Security_Site_Visit_Form.pdf PDF
App_B_-_SCADA_Specs_Screen_Shots.pdf PDF
SCADA_TSpecs.pdf PDF
App_E_-_Sample_Reports.pdf PDF
W912P518T0003.pdf PDF
App_D_-_SCADA_REFERENCE_DRAWINGS.pdf PDF
Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

W912P518T0003

US Army Corps Of Engineers Nashville District

SYSTEMWIDE SCADA UPGRADE

Various Powerplants Cumberland River Basin

Tennessee and Kentucky

Technical Specifications Appendix C – NETWORK DIAGRAMS

January 2018

THIS PAGE INTENTIONALLY LEFT BLANK

FOR DUPLEX PRINTING

T1 Channel

Bank

Old Hickory Units, Xfmrs, Station

Revenue Meters

ESS

Metering Data

Master A

PCS

Old Hickory/J. Percy Priest/Cheatham SCADA System

Old Hickory

Master B

PCS

Managed switch

M ic ro w av e to C

H E

B ac ku p

Microwave Radio

Microwave Phone

NAS MyCloud

Moxa Nport

Mini 8 MSU

CHE camera receiver

D ed ic at ed T ci rc ui t to

J

PP

B ac ku p

D ed ic at ed T ci rc ui t to

J

PP

D ed ic at ed T ci rc ui t to

C H

E

TVA Metering Channel 1 for TVA

TVA Metering Channel 2 for LRN

Yokogawa Plant

Yokogawa Xfmr

Yokogawa Gen4

Yokogawa Gen3

Yokogawa Gen2

Yokogawa Gen1

JPP camera receiver

To Germantown for TVA

TVA network

For Official Use Only

FOR R

EFERENCE O

NLY

APPENDIX C - NETWORK DIAGRAMS OLD HICKORY, J PERCY PRIEST, AND CHEATHAM

G2HDCMRM

Callout Contractor shall provide new SCADA Master Station servers, workstations, and networking equipment

G2HDCMRM

Polygon

Metering RTU

SCADA RTU

Cisco 2921 ISR

Managed Switch

J. Percy Priest Units, Xfmrs, Station

Revenue Meters

Yokagawa

DX2040142

Unit Temp Recorder

J. Percy Priest

Moxa Nport

TVA Metering Channel 2 for

LRN

TVA

Metering Channel 1 for TVA

D ed ic at ed T ci rc ui t to

O ld

/P

D ed ic at ed B ac ku p T1 to

O

LD

/P

Adtran 600e for TVA metering

RuggedCom Serial to Ethernet

JPP camera transmitter

For Official Use Only

FOR R

EFERENCE O

NLY

APPENDIX C - NETWORK DIAGRAMS OLD HICKORY, J PERCY PRIEST, AND CHEATHAM

G2HDCMRM

Callout Contractor shall provide new SCADA RTU and networking equipment

Microwave Phone

SCADA RTU

TVA

Metering RTU

Cheatham Units, Xfmrs, Station

Revenue Meters

Microwave Radio

Yokagawa

DX2040142

Unit Temp Recorders RuggedCom

Serial to Ethernet

Managed switch

Cheatham

TVA

Metering Channel 2 for LRN

TVA

Metering Channel 1 for TVA

TVA

metering

Moxa Nport

D ed ic at ed T to

O

LD

/P

M ic ro w av e

B ac ku p to O

LD

/P

CHE camera

For Official Use Only

To Germantown for TVA

TVA

network

FOR R

EFERENCE O

NLY

APPENDIX C - NETWORK DIAGRAMS OLD HICKORY, J PERCY PRIEST, AND CHEATHAM

G2HDCMRM

Polygon

G2HDCMRM

Callout Contractor shall provide new SCADA RTU and networking equipment

Tetragenics

SCADA RTU

WOL and LAU Outgoing Metering POTS One Way FAX

Windows 7

Wolf Creek Master Site

Laurel River Remote Site

Blackbox 16 Port Switch

Spare Windows 7

Moxa Nport Model 5610-8

Revenue Meter Data

Windows 7

Moxa Nport serial to IP

Model 5610-8

COM 1

Serial

Blackbox 16 Port Switch

TVA Revenue Meter Serial Connection

WOL Cisco 2921 Router

VWIC3

2MFT

T1/E1 CD/LP ALP0CD/LP ALP1

VWIC3

2MFT

T1/E1 CD/LP ALP0CD/LP ALP1

TVA Revenue Meter Serial Connection

LAU Cisco 2921 Router

Satellite backup link

De di ca te d T1

APPENDIX C - NETWORK DIAGRAMS WOLF CREEK AND LAUREL RIVER

G2HDCMRM

Polygon

G2HDCMRM

Polygon

G2HDCMRM

Callout Contractor shall provide new SCADA Master Station servers, workstations, and networking equipment

G2HDCMRM

Callout Contractor shall provide new SCADA RTUs and networking equipment

T1Channel Bank Adtran 600E

Dedicated T1 Circuit

Outgoing Metering

POTS (FAX)

Windows 7

Tetragenics

SCADA RTU

Cordell Hull Master Site

Center Hill Remote Site

Linksys 16 port Switch

Spare Windows 7

Moxa Nport Model 5610-8

Yokagawa

DX2040142

Unit Temp Recorders

T1Channel Bank Adtran 600E

Windows 7

Nport serial to IP

Tetragenics

SCADA RTU

Dale Hollow Remote Site

Yokagawa

DX2040142

Unit Temp Recorders

Dell T3400 Windows XP Pro Nport serial to IP

Tetragenics Unit Speed

Relays

Schweitzer

SEL2032

Units, Xfmrs, Station Revenue Meters

TVA

Metering RTU

Units, Xfmrs, Station Revenue Meters

TVA serial Metering RTU

VWIC3

2MFT

T1/E1 CD/LP ALP0CD /LP ALP1

COR Cisco 2921 Router

DAL Cisco 2921 Router

VWIC3

2MFT

T1/E1 CD/LP ALP0CD/LP ALP1

Cordell Hull Units, Xfmrs, Station

Revenue Meters

TVA

Metering RTU

Blackbox Switch

APPENDIX C - NETWORK DIAGRAMS CENTER HILL, CORDELL HULL, AND DALE HOLLOW

G2HDCMRM

Polygon

G2HDCMRM

Callout Contractor shall provide new SCADA Master Station servers, workstations, and networking equipment

G2HDCMRM

Callout Contractor shall provide new SCADA RTUs and networking equipment

COVER
App C1 - OLD Network Dia 2014
Old Hickory�
JPP�
Cheatham�
App C2 - WOL_LAU No IP
Page-1�
App C3 - CEN_COR_DAL No IP
Page-1�

File details come from the government source that posted it.