Text version
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
0 0
A N
S I
D
C U
M B
E R
L A
N D R
IV
E R W
A T
E R
S H
E D
W P
B
F C
M
/2
/2
F
M
F C
M
F C
M S
IT
E R
E S
T O
R A
T
IO
N
H W
Y
C
U L
V E
R T R
E P
L A
C E
M E
N T
C E
N T
E R H
IL
L D
M
/2
/2
N A
S H
V
IL
L E T
E N
N E
S S
E E
N A
S H
V
IL
L E D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N
S H
V
IL
L E D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
Q -C
H S
R
R E -6
.d g n
Y
M
2. NOTIFY THE COR NO LESS THAN TWO WEEKS PRIOR TO POWER CUTOFF
PROPOSED ORDER OF WORK FOR POWER SHUTOFF.
THE CAMPSITES LOCATED WEST OF NEW HWY 141 CULVERT. SUBMIT
1. DIAGRAM PROVIDED TO FACILITATE TEMPORARY POWER SHUTOFF TO
NOTE:
M P
G R
O U
N D E
L E
C T
R
IC
A L D
IA
G R
A M
RE-600
N A
S H
V
IL
L E T
N
EXISTING AC POWER PANEL
CAMPGROUND PARKING LOT DAY USE
EXISTING AC POWER PANEL
AND A BATH HOUSE
CAMPSITES 15-31,
EXISTING AC POWER PANEL
CAMPSITES 49-57
M
M
M
M
MM
SEE NOTE 2
PULL BOX
EXISTING AC POWER PANEL
CAMPGROUND ATTENDANT
15A35A
50A 35A15A 15A
A
A
A
W/H METER
CLASS 20
FORM 4S
W/H METER
CLASS 20
FORM 4S
W/H METER
CLASS 20
FORM 4S
W/H METER
CLASS 20
FORM 4S
W/H METER
CLASS 20
FORM 4S
W/H METER
CLASS 20
FORM 4S
13800-4160/2400V
750kVA
CONTINUED ON DWG. Q-4/783A
CIRCUIT PHASE C AND A
IN 1-3" PVC COND. SCH-80
EPR CU 5kV
2-1/c #6 & #6 GND
CIRCUIT PHASE B AND C
IN 1-3" PVC COND. SCH-80
EPR CU 5kV
2-1/c #6 & #6 GNDCIRCUIT PHASE A AND B
IN 1-3" PVC COND. SCH-80
EPR CU 5kV
2-1/c #6 & #6 GND
AND 1-3" PVC COND. SCH-80 SPARE
IN 2-3" PVC COND. SCH-80,
EPR CU 5kV
4-1/c #6 & #6 GND
EXISTING AC POWER PANEL
CAMP SITES 32-48, 58-60
EXISTING AC POWER PANEL
AND A BATH HOUSE
CAMPSITES 1-14
W/H METER
CLASS 20
FORM 4S
AND 1-3" PVC COND. SCH-80 SPARE
IN 3" PVC COND. SCH-80,
2-1/c #6 EPR CU 5KV & #6 GND
AND 1-3" PVC COND. SCH-80 SPARE
IN 3" PVC COND. SCH-80,
EPR CU 5kV
2-1/c #6 & # 6 GND
AND 1-3" PVC COND. SCH-80 SPARE
IN 3" PVC COND. SCH-80,
EPR CU 5kV
2-1/c #6 & # 6 GND
AND 1-3" PVC COND. SCH-80 SPARE
IN 2-3" PVC COND. SCH-80,
EPR CU 5kV
4-1/c #6 & #6 GND
5kV MVS SWITCHGEAR
PULL BOX
4160-120/240V
1 PHASE
50kVA
T-1
4160-120/240V
1 PHASE
25kVA
T-2
4160-120/240V
1 PHASE
25kVA
T-3
4160-120/240V
1 PHASE
75kVA
T-4
4160-120/240V
1 PHASE
50kVA
T-5
4160-120/240V
1 PHASE
25 KVA
T-S1 15A
M M
25 KVA
T-S4
W/H METER
CLASS 20
FORM 4S
W/H METER
CLASS 20
FORM 4S
15A15A
FOR LIFT STA. NO. 1
DUPLEX CONTROLLER
FOR LIFT STA. NO. 3
DUPLEX CONTROLLER
FOR LIFT STA. NO. 4
DUPLEX CONTROLLER
EXISTING AC POWER PANEL
CONSTRUCTION OFFICE
IN 1-3" PVC COND. SCH-80,
EPR CU 5kV
3-1/c 1/} & 1/} GND
4160-120/240V
1 PHASE
25kVA
T-S3
25 KVA
T-6
AND 1-3" PVC COND. SCH-80 SPARE
IN 3" PVC COND. SCH-80,
EPR CU 5kV
2-1/c #6 & #6 GND
BOX
PULL
CONDUCTORS
EXISTING
RE-USE
CONDUCTORS
EXISTING
RE-USE
FOR LIFT STA. NO. 2
DUPLEX CONTROLLER
M
W/H METER
CLASS 20
FORM 4S
25 KVA
T-S2
15A
100 AMP
100 AMP 100 AMP 100 AMP
File details come from the government source that posted it.