W912P5-17-R-0002_Contract_Drawings.pdf

PDF 32 MB Posted

Attached to
Wolf Creek Station Service Upgrade
Solicitation number
W912P5-17-R-0002
Issued by

View the file

Other files

File Type Posted
W912P5-17-R-0002Am2-TechChanges.pdf PDF
W912P5-17-R-0002_TSpecsAm2page.pdf PDF
Sol_W912P5-17-R-0002_WOL_Station_Svcs_Amend_02.pdf PDF
20171024_104457.jpg JPG image
Q&A_-_Wolf_Creek_Station_Services_Responses_112017-Final.pdf PDF
20171024_104834.jpg JPG image
20171024_113310.jpg JPG image
20171024_110548.jpg JPG image
20171024_104658.jpg JPG image
20171024_105420.jpg JPG image
20171024_105605.jpg JPG image
20171024_112227.jpg JPG image
20171024_104217.jpg JPG image
20171024_104152.jpg JPG image
W912P5-17-R-0002_TSpecsAm1pages17-Nov-2017.pdf PDF
20171024_105446.jpg JPG image
20171024_105615.jpg JPG image
20171024_105428.jpg JPG image
20171024_104703.jpg JPG image
Sol_W912P5-17-R-0002_WOL_Station_Svcs_Amend_01.pdf PDF
20171024_104207.jpg JPG image
20171024_112707.jpg JPG image
20171024_104842.jpg JPG image
20171024_111739.jpg JPG image
20171024_112654.jpg JPG image
20171024_110121.jpg JPG image
20171024_105506.jpg JPG image
20171024_104858.jpg JPG image
W912P5-17-R-0002Am1-TechChanges17-Nov-2017.pdf PDF
20171024_105458.jpg JPG image
20171024_110432.jpg JPG image
20171024_111511.jpg JPG image
Site_Visit_Request_Form.pdf PDF
Foreign_National_Security_Site_Visit_Form.pdf PDF
W912P5-17-R-0002_TSpecs.pdf PDF
W912P5-17-R-0002.pdf PDF
W912P5-17-R-0002_Reference_Drawings.pdf PDF
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S T

E V

E N R

M

IL

E S P .E

A N

S I E

V

IC

IN

IT

Y M

A P

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

N A

S H

V

IL

L E T

E N

N E

S S

E E

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

S T

A T

IO

N S

E R

V

IC

E U

P G

R A

D E

P O

W E

R H

O U

S E

C U

M B

E R

L A

N D R

IV

E R

W O

L F C

R E

E K D

A M

W C

P .0

G -0

X X

X .d g n

/1

/2

G

H D

C C

L G

A B

D U

L S

A W

A B

P R

O J E

C T L

O C

A T

IO

N

G-001

Nashville District of Engineers

US Army Corps

A N

D W

C P -1 .0

-6 -0 -D -0 /1

SCALE: NONE

SITE PLAN

VICINITY MAP

PROJECT LOCATION

STATION SERVICE UPGRADE

WOLF CREEK POWERHOUSE

CUMBERLAND RIVER - KENTUCKY

D

K W

O N

G

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

1 2 3 4 5 6

E

D

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/8 /2

DRAWING PLOT SIZE: ANSI E DATE AND TIME PLOTTED: 1/8/2016 9:53:56 AM BY USERNAME: g2hdcclg Chuck Gierek SHEET NAME: G-001

D E

S

IG

N F

IL

E n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

BORDER VERSION UPDATE [09-2012]

E V

E N R

M

IL

E S P .E

A N

S I

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

N A

S H

V

IL

L E T

E N

N E

S S

E E

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

S T

A T

IO

N S

E R

V

IC

E U

P G

R A

D E

P O

W E

R H

O U

S E

C U

M B

E R

L A

N D R

IV

E R

W O

L F C

R E

E K D

A M

/1

/2

G

H D

C C

L G

A B

D U

L S

A W

A B

G-002

IN

D

E X O

F D

R A

W

IN

G

W

C P -1 .0

-6 -0 -D -0 /2

W C

P .0

G -0

X X

X .d g n

NO.

SHEET

DRAWING NUMBER TITLETITLE

NO.

SHEET

FILE NUMBER CADD FILE NAME

REFERENCE DRAWINGS

ELECTRICAL

INDEX TO DRAWINGS

CONTRACT DRAWINGS

GENERAL

G-004

G-003

G-002

G-001

WCP-1.001-6-0-D-0/4

WCP-1.001-6-0-D-0/3

WCP-1.001-6-0-D-0/2

WCP-1.001-6-0-D-0/1

WCP1.001_G-004XXX.dgn

WCP1.001_G-003XXX.dgn

WCP1.001_G-002XXX.dgn

WCP1.001_G-001XXX.dgn

D

K W

O N

G

CROSS SECTION DISMANTLING PLATFORM

PROJECT PLAN / POWERHOUSE ACCESS CONTRACTOR STAGING

INDEX OF DRAWINGS

PROJECT LOCATION

REFERENCE DRAWINGS

S-501

E-802

E-801

E-714

E-713

E-712

E-711

E-710

E-708

E-707

E-706

E-705

E-704

E-682

E-680

E-653

E-652

E-651

E-605

E-604

E-603

E-602

E-601

E-208

E-207

E-206

E-205

E-204

E-203

E-202

E-201

E-200

E-106

E-104

E-103

E-102

E-101

E-100

E-001

ED802

ED801

ED704

ED703

ED702

ED683

ED682

ED681

ED680

ED611

ED610

ED605

ED603

ED602

ED601

ED208

ED207

ED206

ED205

ED204

ED203

ED201

ED106

ED105

ED104

ED103

ED102

ED101

ED100

WCP1.001_S-501XXX.dgn

WCP1.001_E-802XXX.dgn

WCP1.001_E-801XXX.dgn

WCP1.001_E-714XXX.dgn

WCP1.001_E-713XXX.dgn

WCP1.001_E-712XXX.dgn

WCP1.001_E-711XXX.dgn

WCP1.001_E-710XXX.dgn

WCP1.001_E-708XXX.dgn

WCP1.001_E-707XXX.dgn

WCP1.001_E-706XXX.dgn

WCP1.001_E-705XXX.dgn

WCP1.001_E-704XXX.dgn

WCP1.001_E-682XXX.dgn

WCP1.001_E-680XXX.dgn

WCP1.001_E-653XXX.dgn

WCP1.001_E-652XXX.dgn

WCP1.001_E-651XXX.dgn

WCP1.001_E-605XXX.dgn

WCP1.001_E-604XXX.dgn

WCP1.001_E-603XXX.dgn

WCP1.001_E-602XXX.dgn

WCP1.001_E-601XXX.dgn

WCP1.001_E-208XXX.dgn

WCP1.001_E-207XXX.dgn

WCP1.001_E-206XXX.dgn

WCP1.001_E-205XXX.dgn

WCP1.001_E-204XXX.dgn

WCP1.001_E-203XXX.dgn

WCP1.001_E-202XXX.dgn

WCP1.001_E-201XXX.dgn

WCP1.001_E-200XXX.dgn

WCP1.001_E-106XXX.dgn

WCP1.001_E-104XXX.dgn

WCP1.001_E-103XXX.dgn

WCP1.001_E-102XXX.dgn

WCP1.001_E-101XXX.dgn

WCP1.001_E-100XXX.dgn

WCP1.001_E-0O1XXX.dgn

WCP1.001_ED802XXX.dgn

WCP1.001_ED801XXX.dgn

WCP1.001_ED704XXX.dgn

WCP1.001_ED703XXX.dgn

WCP1.001_ED702XXX.dgn

WCP1.001_ED683XXX.dgn

WCP1.001_ED682XXX.dgn

WCP1.001_ED681XXX.dgn

WCP1.001_ED680XXX.dgn

WCP1.001_ED611XXX.dgn

WCP1.001_ED610XXX.dgn

WCP1.001_ED605XXX.dgn

WCP1.001_ED603XXX.dgn

WCP1.001_ED602XXX.dgn

WCP1.001_ED601XXX.dgn

WCP1.001_ED208XXX.dgn

WCP1.001_ED207XXX.dgn

WCP1.001_ED206XXX.dgn

WCP1.001_ED205XXX.dgn

WCP1.001_ED204XXX.dgn

WCP1.001_ED203XXX.dgn

WCP1.001_ED201XXX.dgn

WCP1.001_ED106XXX.dgn

WCP1.001_ED105XXX.dgn

WCP1.001_ED104XXX.dgn

WCP1.001_ED103XXX.dgn

WCP1.001_ED102XXX.dgn

WCP1.001_ED101XXX.dgn

WCP1.001_ED100XXX.dgn

WCP-1.001-5-1-D-40/16

WCP-1.001-6-1-D1/2

WCP-1.001-6-1-D1/1

WCP-1.001-6-9-D-40/32

WCP-1.001-6-9-D-40/31

WCP-1.001-6-9-D-40/30

WCP-1.001-6-9-D-40/29

WCP-1.001-6-9-D-40/28

WCP-1.001-6-9-D-42/5

WCP-1.001-6-9-D-42/11

WCP-1.001-6-9-D-42/10

WCP-1.001-6-9-D-42/4

WCP-1.001-6-9-D-42/3

WCP-1.001-6-9-D-42/2

WCP-1.001-6-9-D-42/1

WCP-1.001-6-9-D-20/5

WCP-1.001-6-9-D-20/4

WCP-1.001-6-9-D-20/3

WCP-1.001-6-9-D-20/2

WCP-1.001-6-9-D-21/7

WCP-1.001-6-9-D-21/6

WCP-1.001-6-9-D-21/5

WCP-1.001-6-9-D-21/4

WCP-1.001-6-9-D-21/2

WCP-1.001-6-9-D-21/1

WCP-1.001-6-9-D-40/15

WCP-1.001-6-9-D-40/13

WCP-1.001-6-9-D-40/12

WCP-1.001-6-9-D-40/11

WCP-1.001-6-9-D-40/10

WCP-1.001-6-9-D-40/9

WCP-1.001-6-9-D-40/16

WCP-1.001-6-9-D-40/8

WCP-1.001-6-9-D-40/7

WCP-1.001-6-9-D-40/5

WCP-1.001-6-9-D-40/4

WCP-1.001-6-9-D-40/3

WCP-1.001-6-0-D-0/3

WCP-1.001-6-9-D-40/2

WCP-1.001-6-9-D-40/30

WCP-1.001-6-9-D-40/1

WCP-1.001-6-1-D-1/5

WCP-1.001-6-9-D-42/9

WCP-1.001-6-9-D-42/8

WCP-1.001-6-9-D-20/12

WCP-1.001-6-9-D-20/11

WCP-1.001-6-9-D-20/10

WCP-1.001-6-9-D-20/9

WCP-1.001-6-9-D-20/8

WCP-1.001-6-9-D-20/7

WCP-1.001-6-9-D-20/6

WCP-1.001-6-9-D-20/5

WCP-1.001-6-9-D-21/10

WCP-1.001-6-9-D-21/9

WCP-1.001-6-9-D-40/27

WCP-1.001-6-9-D-40/26

WCP-1.001-6-9-D-40/25

WCP-1.001-6-9-D-40/24

WCP-1.001-6-9-D-40/23

WCP-1.001-6-9-D-40/22

WCP-1.001-6-9-D-40/21

WCP-1.001-6-9-D-40/29

WCP-1.001-6-9-D-40/20

WCP-1.001-6-9-D-40/19

WCP-1.001-6-9-D-40/18

WCP-1.001-6-9-D-40/17

WCP-1.001-6-9-D-40/16

WCP-1.001-6-9-D-40/15

POWERHOUSE ARRANGEMENT PLAN EL. 595.00 UNITS 4,5 & 6 REMOVAL

POWERHOUSE ARRANGEMENT PLAN EL. 567.00 UNITS 1,2 & 3 REMOVAL

POWERHOUSE ARRANGEMENT PLAN EL. 567.0 UN. 4,5,6 REMOVAL

SS GENERATOR BUS DUCT GENERAL ARRANGEMENT REMOVAL

15KV STATION SERVICE SWITCHGEAR SECTIONAL UN. T2,T3 SS TRANSORM REMOVAL

STATION SERVICE SWITCHGEAR LAYOUT REMOVAL

U1 - U7 LAYOUT & NAMEPLATE REMOVAL

U8 - U9 LAYOUT & NAMEPLATE REMOVAL

V1 LAYOUT & NAMEPLATE REMOVAL

V2 LAYOUT & NAMEPLATE REMOVAL

MAIN CONTROL SWITCHBOARD AND BENCHBOARD LAYOUT REMOVAL

MAIN CONTROL SWITCHBOARD REAR LAYOUT REMOVAL

MAIN ONE LINE DIAGRAM REMOVAL

THREE LINE DIAGRAM STATION SERVICE REMOVAL

STATION SERVICE ONE LINE DIAGRAM REMOVAL

DC DISTRIBUTION SYSTEM SINGLE LINE DIAGRAM REMOVAL

CONTROL SCHEMATIC RELAYS SS tRANSFORMER AND SS GENERATOR REMOVAL

SCHEMATIC DIAGRAM STATION SERVICE REMOVAL

SCHEMATIC DIAGRAM V1 CONTROL REMOVAL

SCHEMATIC DIAGRAM V1 MASTER CONTROL REMOVAL

SCHEMATIC DIAGRAM V2 CONTROL REMOVAL

SCHEMATIC DIAGRAM V2 MASTER CONTROL

WIRING DIAGRAMS SWITCHBOARD MM PANEL 7 REMOVAL

WIRING DIAGRAMS SWITCHBOARD MR PANEL 7 REMOVAL

WIRING DIAGRAMS SWITCHBOARD MB PANEL 7 REMOVAL

ELECTRICAL NOTES AND LEGEND INSTALL

POWERHOUSE ARRANGEMENT PLAN EL. 595.0 UN. 1,2,3 INSTALL

POWERHOUSE ARRANGEMENT PLAN EL. 567.0 UN. 1,2,3 INSTALL

POWERHOUSE ARRANGEMENT PLAN EL. 567.0 UN. 4,5,6 INSTALL

POWERHOUSE ARRANGEMENT PLAN EL. 595.0 UN. 4,5,6 INSTALL

15KV STATION SERVICE SWITCHGEAR SECTIONAL UN. T2, T3, SS TRANSFROM INSTALL

SERVICE STATION SWITCHGEAR LAYOUT INSTALL

SERVICE STATION SWITCHGEAR LAYOUT INSTALL

MOTOR CONTROL CENTERS U1 TO U7 LAYOUT & NAMEPLATE INSTALL

MOTOR CONTROL CENTERS U8 & U9 LAYOUT & NAMEPLATE INSTALL

MOTOR CONTROL CENTERS V1 & V2 LAYOUT & NAMEPLATE INSTALL

MOTOR CONTROL CENTERS V1 & V2 LAYOUT & NAMEPLATE INSTALL

MAIN CONTROL SWITCHBOARD AND BENCHBOARD LAYOUT INSTALL

MAIN CONTROL SWITCHBOARD REAR LAYOUT INSTALL

MAIN ONE LINE DIAGARM INSTALL

THREE LINE DIAGRAM STATION SERVICE INSTALL

480V STATION SERVICE SYSTEM ONE LINE DIAGRAM INSTALL

ONE LINE DIAGRAM V1 VENTIALATION BUS INSTALL

DC DISTRIBUTION SYSTEM SINGLE LINE DIAGRAM INSTALL

CONTROL SCHEMATC RELAYS SS TRANSFORMER AND SS GENERATOR INSTALL

STATION SERVICE SWITCHGEAR CONTROL DIAGRAM SHEET 1 OF 2 INSTALL

SCHEMATIC DIAGARM STATION SERVICE SHEET 1 OF 3 INSTALL

SCHEMATIC DIAGRAM V1 CONTROL INSTALL

SCHEMATIC DIAGRAM V2 CONTROL INSTALL

WIRING DIAGRAMS SWITCHBOARD MB PANEL 7 INSTALL

WIRING DIAGRAMS SWITCHBOARD MR PANEL 7 87TS1 INSTALL

WIRING DIAGRAMS SWITCHBOARD MR PANEL 7 87TS2 INSTALL

WIRING DIAGRAMS SWITCHBOARD SS PANEL MR1 INSTALL

WIRING DIAGRAMS SWITCHBOARD SS PANEL MR2 INSTALL

LOCAL/REMOTE CABINET ELEVATION INSTALL

CONDUIT & CABLE SCHEDULE SHEET 1 OF 2 INSTALL

CONDUIT & CABLE SCHEDULE SHEET 2 OF 2 INSTALL

POWERHOUSE ARRANGEMENT PLAN EL. 595.00 UNITS 1,2 & 3 REMOVAL

SITE PLAN - VILLAGE & SWITCHYARD FEEDER CONDUIT ROUTING REMOVAL

CONDUIT & CABLE SCHEDULE SHEET 2 OF 2 REMOVAL

CONDUIT & CABLE SCHEDULE SHEET 1 OF 2 REMOVAL

SITE PLAN - VILLAGE & SWITCHYARD FEEDER CONDUIT ROUTING

SERVICE STATION SWITCHGEAR LAYOUT & NAMEPLATE

15 KV STATION SERVICE SWITCHGEAR SECTIONAL UN. T2, T3, SS TRANSFORM

WIRING DIAGRAMS SWITCHBOARD SS PANEL WIRING TERMINATIONS SHEET 1

WIRING DIAGRAMS SWITCHBOARD SS PANEL WIRING TERMINATIONS SHEET 2

WIRING DIAGRAMS SWITCHBOARD MR PANEL 4 INSTALL

WIRING DIAGRAMS SWITCHBOARD MR PANEL 2 INSTALL

q-2^731j q-2^731h.1 wcp201 q-2-78/28.1 q-2/8397S q-2-56/2.3 q-2-79/725.2 q-2/842F.2 q-2/828b.8 q-2/716.1 q-2/78/28.1 q-2/56/14.4

WCP56.5

wcp40.3 q-2/853g a-2/842k.5 q-2/839a.5 q-2/838a.1 q-2/838.2 q-2/837.2 q-2/834w q-2/834v.1 q-2/834t.1 q-2/834s.1 q-2/834r.2 q-2/834m.3 q-2/834l.2 q-2/834k.3 q-2/834j.2 q-2/834g.4 q-2/834f.5 q-2/829.6 q-2/829b.3 q-2/828e.5 q-2/828d.5 q-2/828c.8 q-2/828b.8 q-2/828a.5 q2/827c6 q-2/827a.4 q-2/827.7 q-2/801.2 q-2/800.2 q-2/797.2 q-2/795.2 q-2/794.2 q-2/793.1 q-2/792.1 q-2/790.2 q-2/787.1 q-2/786.1 q-2/754a q-2/754.1 q-2/753a.4 q-2/753.3 q-2/752a.2 q-2/752.4 q-2/742a.1 q-2/742.1 q-2/741a.1 q-2/741.1 q-2/736.3 q-2/735a.1 q-2/735.1 q-2/731a.2 q-2/731.4 q-2/730a.1 q-2/729a q-2/729.5

MISCELLANEOUS METAL DETAILS - DISMANTALING PLATFORM BALCONY EL. 595.0

GENERAL ARRANGEMET - DISMANTALING PLATFORM BALCONY ELEVATION 595.0

DC DISTRIBUTION SINGLE LINE DIAGRAM

MULTILEVEL WATER INTAKE VALVE ACTUATOR PLAN

ELECTRICAL PYLON CONDUIT LAYOUT SECTIONS

WIRING DIAGRAM - GENERAL POWER

ARRANGEMENT IN SPREAD ROOM AND TELEPHONE ROOM

TUNNEL ELECTRICAL INSTALLATION CABLE TRAYS

POWER WIRING DETAILS - ELEV. 580.0

POWER WIRING PLAN - ELEV. 595.0 UNITS 1 THRU 6

INTAKE GATE FEEDERS

ELECTRICAL PYLON CONDUIT LAYOUT

REAR VIEW WIRING DIAGRAM PANEL NO.7 SWITCHBOARD MR

STATION SERVICE SCHEMATIC DIAGRAMS

UNWATERING AND DRAINAGE SUMPS FOR UNITS NO.1-2-3-4-5-&6 WIRING DIAGRAM

CABLE TUNNEL ELECTRICAL INSTALLATION

SPREAD ROOM ARRANGEMENT SECTIONS

STATION GROUND NETWORK PLAN EL 567.& 0 580.0 UNITS 4,5,AND 6

STATION GROUND NETWORK PLAN EL 580.0 UNITS 1,2,3 AND DETAILS

STATION GROUND NETWORK PLAN EL 567.0 UNITS 1,2,3 AND SECTION

CONNECTION DIAGRAMS CONTROL CENTERS V2

CONNECTION DIAGRAMS CONTROL CENTERS V1

CONNECTION DIAGRAMS CONTROL CENTERS U8 AND MISC. STA. SERV

CONNECTION DIAGRAMS CONTROL CENTERS U7

CONNECTION DIAGRAMS CONTROL CENTERS U1-U6

SCHEMATIC DIAGRAMS, VENTILATION ZONE 2 MASTER CONTROL

SCHEMATIC DIAGRAMS, VENTILATION ZONE 2 CONTROL

SCHEMATIC DIAGRAMS, VENTILATION ZONE 1 MASTER CONTROL

SCHEMATIC DIAGRAMS, VENTILATION ZONE 1 CONTROL

SCHEMATIC DIAGRAMS, CONTROL CENTERS U8 AND U9

SCHEMATIC DIAGRAMS, CONTROL CENTERS U1 TO U7 INCL.

POWER WIRING DETAILS EL. 595.0 UNITS 1 THRU 6

POWER WIRING DETAILS EL. 580.0 & 595.0

POWER WIRING DETAILS EL. 580.0 UNITS 4, 5, & 6 downstream trays

POWER WIRING DETAILS EL. 580.0 UNITS 4, 5, & 6 upstream trays

POWER WIRING DETAILS EL. 580.0 UNITS 1, 2, & 3 downstream trays

POWER WIRING DETAILS EL. 580.0 UNITS 1, 2, & 3 upstream trays

POWER WIRING PLAN EL. 580.0 UNITS 4,5 & 6

POWER WIRING DETAILS EL. 567.0 * Not found in reference drawings

POWER WRING PLAN EL. 567.0 UNITS 4, 5, & 6

POWER WRING PLAN EL. 567.0 UNITS 1, 2, & 3

VENTILATION CONTROL CENTER V2

VENTILATION CONTROL CENTER V1

SS GEN AND STATION SERVICE XFMR BUS DUCTS GENERAL ARRANGEMENT

STATION SERVICE UNIT FIELD PANELS F7 & 460 VOLT CONTROL CENTERS U8 AND U9

460 VOLT CONTROL CENTERS U1-7 INCL.

MAIN STATION SERVICE SWITCHGEAR

STATION SERVICE SINGLE LINE DIAGRAM

15KV STATION SERVICE SWITCHGEAR EQPT., UNITS T2,T3 AND SSTRANSF.

MAIN CONTROL SWITCHBOARD RELAY PANELS MR &AND OPERATORS DESK

MAIN CONTROL SWITCHBOARD, BENCHBOARD MB & INSTRUMENT PANELS MM

REINFORCED CONCRETE - PLAN ROOF - UNITS 4-5 & 6

REINFORCED CONCRETE - PLAN ROOF - UNITS 1-2 & 3

REINFORCED CONCRETE - PLAN ELEVATION 611.0 - UNITS 4-5 & 6

REINFORCED CONCRETE - PLAN ELEVATION 611.0 - UNITS 1-2 & 3

REINFORCED CONCRETE - PLAN ELEVATION 595.0 - UNITS 4-5 & 6

REINFORCED CONCRETE - PLAN ELEVATION 595.0 - UNITS 1-2 & 3

STRUCTURAL STEEL PLAN - ELEVATION 611.0 - UNITS 4-5 & 6

STRUCTURAL STEEL PLAN - ELEVATION 611.0 - UNITS 1-2 & 3

STRUCTURAL STEEL PLAN - ELEVATION 595.0 - UNITS 4-5 & 6

STRUCTURAL STEEL PLAN - ELEVATION 595.0 - UNITS 1-2 & 3

CROSS SECTION - DISMANTLING PLATFORM

CROSS SECTION - CENTERLINE OF UNIT NO. 5

CROSS SECTION - CENTERLINE OF UNIT NO. 2

POWERHOUSE FLOOR PLAN - ELEVATION 595.0 UNITS NO. 4-5-6

POWERHOUSE FLOOR PLAN - ELEVATION 595.0 UNITS NO. 1-2-3

POWERHOUSE FLOOR PLAN - ELEVATION 580.0 UNITS. NO 4-5-6

POWERHOUSE FLOOR PLAN - ELEVATION 567.0 UNITS. NO. 4-5-6

POWERHOUSE FLOOR PLAN - ELEVATION 567.0 UNITS NO. 1-2-3

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/8 /2

DRAWING PLOT SIZE: ANSI E DATE AND TIME PLOTTED: 1/8/2016 9:54:45 AM BY USERNAME: g2hdcclg Chuck Gierek SHEET NAME: G-004

D E

S

IG

N F

IL

E n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

E V

E N R

M

IL

E S P .E

A N

S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

N A

S H

V

IL

L E T

E N

N E

S S

E E

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

S T

A T

IO

N S

E R

V

IC

E U

P G

R A

D E

P O

W E

R H

O U

S E

C U

M B

E R

L A

N D R

IV

E R

W O

L F C

R E

E K D

A M

W C

P .0

G -0

X X

X .d g n

/1

/2

G

H D

C C

L G

A B

D U

L S

A W

A B

G-003

O N

T R

A C

T O

R S

T A

G

IN

G

P R

O J E

C T P

L A

N P

O W

E R

H O

U S

E A

C C

E S

S W

C P -1 .0

-6 -0 -D -0 /3

NOTES:

SITE PLAN - CONTRACTOR STAGING & STORAGE AREA

SCALE: NONE

REFERENCE DRAWINGS:

ELECTRICAL PYLON CONDUIT LAYOUT SECTIONS

SPREAD ROOM ARANGEMENT

ARRANGEMENT IN SPREAD ROOM AND TELEPHONE ROOM

POWER WIRING DETAILS - ELEV. 580.0

CABLE TUNNEL - ELECTRICAL INSTALLATION CABLE TRAYS

POWER WIRING PLAN - ELEV. 580.0 UNITS NOS 4,5,6

POWER WIRING DETAILS - ELEV 580.0

POWER WIRING DETAILS - ELEV. 580.0

POWER WIRING PLAN - ELEV. 595.0, UNITS 1 THRU 6

TITLE

Q - 2-56/14.4

Q - 2/8397

Q - 2-79/725.2

Q - 2/828B.8

Q - 2/842F.2

Q - 2/828A.5

Q - 2/828E.5

Q - 2/8280.8

Q - 2/829.6

Q - 2/716.1

DRAWING NO.

SEE NOTE 1

TYPICAL

CONDITION WHEN CONSTRUCTION IS COMPLETED.

& SHALL CLEAN AND RESTORE THE AREA TO ORIGINAL

2. CONTRACTOR SHALL PROTECT THE SITE FROM DAMAGES

STAGING AND STORAGE AREA.

1. THE DASHED BOLD LINES ARE DESIGNATED AS CONTRACTOR

D

K W

O N

G

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/8 /2

DRAWING PLOT SIZE: ANSI E DATE AND TIME PLOTTED: 1/8/2016 9:54:56 AM BY USERNAME: g2hdcclg Chuck Gierek SHEET NAME: G-002

D E

S

IG

N F

IL

E n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

E V

E N R

M

IL

E S P .E

A N

S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

N A

S H

V

IL

L E T

E N

N E

S S

E E

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

S T

A T

IO

N S

E R

V

IC

E U

P G

R A

D E

P O

W E

R H

O U

S E

C U

M B

E R

L A

N D R

IV

E R

W O

L F C

R E

E K D

A M

/1

/2

A B

D U

L S

A W

A

G-004

P -1 .0

-6 -0 -D -0 /4

NOTES:

SCALE: NONE

REFERENCE DRAWINGS:

43'-4" 24'-0" 22'-0" 24'-0" 23'-7"

22'-0" 24'-0" 23'-7" ƒ

1' ƒ

2'-4" 2'-4"32'-8" 32'-8"

R A

D

IU

S

39'-9" 78'-6" 20'-0"

39'-3" 39'-3"

4'-3" 2'-8 •"

4'-3"

59'-3"

2'-8 •"

EL.506.0

STATION DRAINAGE PIPES.

TOP OF PARAPET EL. 660.87

TOP OF PARAPET EL.638.83

DUCT

TOP OF ROOF

SLAB EL.637.5

DUCT

PLASTER

MARBLE

GRILL

MARBLE

MARBLE

ACOUSTICAL TILE CEILING

GLASS

PLASTER

FIN FLOOR EL.611.0

GRILL

TOP OF PARAPET EL.629.33

TOP OF ROOF SLAB EL.638.0

DRAIN

EARTH

FILL

DRAIN

6"0 POROUS

CON DRAIN

EL.605.0

EL.605.0

POWER

CABLE

TUNNEL

UNITS NO.

4,5,&6

POWER

CABLE

TUNNEL

UNIT NO.

1,2,&3

EL. 583.62

6"I.D. HALF ROUND POROUS

CONC. DRAIN-SEE Q 2/7J8G

EL.537.5

NOT IN

POWER HOUSE

CONTRACT

INSIDE

CONTROL

CABLE

TUNNEL

TERRA

COTTA

CONCRETE BLOCK

DUCT

BRICK

DUCTS

ACOUSTICAL TILE CEILING

PLASTER

LINOLEUM BASE

FIN. FLOOR EL.595.0

PLASTER ABOVE

PARTITION.

METAL AND GLASS

PARTITION

TOP OF CRANE RAIL EL.629.0

CRANE RAIL

CRAIN GRIDER

EL.624.23

OPEN

GLAZED TILE DADO

FIN. FLOOR EL.580.0

STORAGE BIN

NOT IN THIS CONTRACT

EL.550.0

CONCRETE

PIPE RAILING

CONC.

CONC.

BLOCK

CONC.

EL.563.0

TERRA COTTA

CONCRETE

TOP OF CRANE

REMOVABLE PIPE RAILINGS

RAIL EL.587.62

EYE BOLTS

OPEN

EL.550.0

FINISH FLOOR EL.564.0

REMOVABLE RAILING

EL.544.33

VENTILATOR

4" FILL AT RIDGE OF ROD

FOR CATWALKS SEE DWG Q2/743 B & C

TOP OF ROOF SLAB EL.659.5 C L

FILTER BOARD CEILING

ON METAL LATH AND PLASTER

SCUTTLE

PIPE RAILING

LADDER

6" T.C.

12"x12"

GLASS

BLOCK

LIGHTS

DUCT

FIN. FLOOR EL.647.5

FIN FLOOR EL.627.75

GATE

SLOT

EL.594.96

CEILING IN TOILET

ROOMS ON THIS

FLOOR TO BE SAME

HEIGHT

NOT IN

POWER HOUSE

CONTRACT

EL.539.33

EL.537.83

GLAZED

TILE

427 405

209 207

VENTILATOR

C OF UNITSL

REMOVABLE RAILING

EL.595.0

FIN. FLOOR

REMOVABLE SLABS

FIN FLOOR EL.580.0

CONCRETE

TOP OF CRANE RAIL EL.587.62

LEDGE

GOVERNOR

OPENING TO

PIT LINER

FIN. FLOOR

EL.564.0

GENERATOR

FLOOR

STAND

DUCT

EL.567.0

OPEN

PENSTOCKCL

EL.553.33

EL.550.0

EL.544.5

EL.540.0

EL.550.0

BOTTOM OF DISCHARGE PIT EL.533.0

EL.541.0

EL.553.67

CONCRETE

EL.564.0

FIN FLOOR

CONCRETE

WATERTIGHT

DOOR

CONCRETE

EL.595.0

FIN FLOOR

CONCRETE

12"x12"

GLASS

BLOCK

GLASS

BLOCK

12"x12"

CONCRETE

AUTOMATIC SHUTTER

OPENING

TOP OF PARAPET EL.660.87

TOP OF ROOF SLAB EL.659.54

FIN. FLOOR EL.627.75

FIN. FLOOR EL.611.0

TOP OF PARAPET

WATER TIGHT HATCH COVER

GATE SLOT COVER

LADDER RUNGS

NOT IN

POWER HOUSE

CONTRACT

7T@9"1-0"

5'-3"

R

EL.532.5

6 •"

4'-0" RADIUS 4'-0" RADIUS

EL.642.00CL

1'-8"

1'-6 ‚" 1'-0"

Q

U A

L

R

IS

E R

S

" FIN FL.EL.553.67

OPEN

EL.567.0

OPEN DUCT

RAMP

2"

EL.580.0

1'-8"

1'-7"

3'-0"

3'-8"

9"9"9"9"

C B A

F E D C B A

D

CROSS SECTION DISMANTLING PLATFORM

Q - 2/736.3

DRAWING NO.

CROSS SECTION DISMANTLING PLATFORM

TITLE

1. THIS DRAWING IS FOR INFORMATION ONLY.

W C

P .0

G -0

X X

X .d g n

D

K W

O N

G

C R

O S

S S

E C

T

IO

N D

IS

M A

N T

L

IN

G P

L A

T F

O

M

CROSS SECTION A-A

CROSS SECTION B-B

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/8 /2

DRAWING PLOT SIZE: ANSI E DATE AND TIME PLOTTED: 1/8/2016 9:56:21 AM BY USERNAME: g2hdcclg Chuck Gierek SHEET NAME: G-004

D E

S

IG

N F

IL

E n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

E V

E N R

M

IL

E S P .E

A N

S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

N A

S H

V

IL

L E T

E N

N E

S S

E E

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

S T

A T

IO

N S

E R

V

IC

E U

P G

R A

D E

P O

W E

R H

O U

S E

C U

M B

E R

L A

N D R

IV

E R

W O

L F C

R E

E K D

A M

W C

P .0

S -5

X X

X .d g n

/1

/2

G

H D

C C

L G

D A

N C

A S

T O

N

IN

S

T A

L L

S-501

W C

P -1 .0

-6 -9 -D -4

/1

NOTES:

N

KEY PLAN

K V S

T A

T

IO

N S

E R

V

IC

E S

W

IT

C H

G E

A R

S E

C T

IO

N A

L U

N T ,T

S

S T

R A

N S

F O

R M

CONFINING STIRRUPS

LOCATE ANCHORS TO MISS

FLANGE OF I-BEAM

OR DAMAGE TENSION

DO NOT ATTACH

CONCRETE HATCH COVER

EL.595.0

EL.595.0

ISOPHASE BUS

EPOXY ANCHOR

SEE NOTE 2, TYP.

SIZE

G-2/741A.1 FOR WIDE FLANGE

REFERENCE FIO DRAWING

Q-2/752A.2

REFERENCE DRAWING FIO

#3 STIRRUPS SPACED 12",

SCALE: NONE

S L

A B

S T

R U

C T

U R

F

IL

L

L

IG

H T

W E

IG

H T

S E

E N

O T

E

M A

X

IM

U M

4 1/4" MIN.

S L

A B

T O

P P

E R

M

IN

E

F F

E C

T

IV

E E

M B

E D

M E

N T

BACKER ROD

CLOSED CELL FROM

GROUT

EXISTING

REMOVE

(UNI-STRUT) CONCEPTUAL ONLY

ISOPHASE BUS SUPPORT

EPOXY

SEE NOTE 1.

MAX. GAP

1/4" TO 1/2"

3" NELSON STUD

FOUNDATION

TRANSFORMER

LEGEND:

/2

N O

N S

H R

IN

K G

R O

U T

M

IN

IM

U M

SEE NOTE 5

/2

M

IN

SEE NOTE 3.

CAULKING

FIRE RATED

TYP.

SEE NOTE 7

SEE NOTE 6

#8 @ 8" MAX. E.W.

S E

E N

O T

E

/2

M

IN

C L E

A R C

O V

E R

M

IN

M A

X

7. MINIMUM 8" GREATER THAN OPENING. DO NOT EXCEED 30"

6. WELD END OF ANGLES TO FORM WELDMENT.

5. LEVEL TOP OF HATCH WITH AJACENT TOPPER SLAB.

LEVEL BEARING SURFACE.

4. OVER EXCAVATE AND GROUT 1 1/2" MIN TO 2" MAX. THICKNESS TO ACHIEVE

3. REFERENCE FIO DRAWING Q-2/752A.2. CONFIRM WITH FIELD MEASUREMENTS.

2. ADHERE TO SPECIFICATION 03 60 FOR CONCRETE REMOVAL.

1. PROVIDE L2 X 2 X 1/4" OR GREATER ANGLE FOR BEARING AT EDGE OF CONCRETE HATCH COVER.

S-501

E

S-501

E

SCALE: 6"=1'-0"

SEALANT DETAIL

E-106

A

SCALE: 1"=1'-0"

HATCH DETAIL

ED105

D

SCALE: 1"=1'-0"

CONCRTE REMOVAL DETAIL

E-106

B

SCALE: 1"=1'-0"

BUS SUPPORT DETAIL

E-106

C

SCALE: 1"=1'-0"

SEISMIC ANCHORING DETAIL

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/8 /2

DRAWING PLOT SIZE: ANSI E DATE AND TIME PLOTTED: 1/8/2016 9:56:34 AM BY USERNAME: g2hdcclg Chuck Gierek SHEET NAME: S-501

D E

S

IG

N F

IL

E n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

E V

E N R

M

IL

E S P .E

A N

S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

N A

S H

V

IL

L E T

E N

N E

S S

E E

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

S T

A T

IO

N S

E R

V

IC

E U

P G

R A

D E

P O

W E

R H

O U

S E

C U

M B

E R

L A

N D R

IV

E R

W O

L F C

R E

E K D

A M

/1

/2

G

H D

C C

L G

A B

D U

L S

A W

A B

ED100

NOTES:

SCALE: NONE

REFERENCE DRAWINGS:

SWITCH

DOSCONNECT

T U

N N

E L

E N

D O

F

W C

P .0

E

D

X X

X .d g n

FEEDER

SUMP PUMP

(SS43 SEE NOTE 5)

SUMP PUMP FEEDER

EXISTING XFMR

SWITCH (SEE NOTE 5)

EXISTING DISCONNECT

(SEE NOTES 2 & 3)

UP TO PYLON BOARD

(SS21, SS111)

HEADGATE FEEDER 1&2

(SS23, SS113) &

DAM FEEDER 1&2

(S E E N

O T E

(S S ,S

S

IN

C

O N

D

IT

IT

C H

Y A

R D F

E E

D E R

5. REMOVE AND REPLACE CABLES FROM "SS" SWITCHGEARUP TO THE DISCONNECT SWITCH.

TERMINATION CLOSE TO THE LOAD.

4. REMOVE AND REPLACE CABLES FROM "SS" SWITCHGEAR UP TO THE FIRST PONT OF

UP TO THE ROADWAY FIRST POINT OF TERMINATION CLOSE TO THE LOAD.

3. REMOVE AND REPLACE CABLES FOR HEAD GATE FEEDERS FROM "SS" SWITCHGEAR

UP TO THE PYLON BOARD.

2. REMOVE AND REPLACE CABLES FOR DAM FEEDERS FROM "SS" SWITCHGEAR

RESTORE THE AREA TO ORIGINAL CONDITION WHEN CONSTRUCTION IS COMPLETED

1. CONTRACTOR SHALL PROTECT THE SITE FROM DAMAGES & SHALL CLEAN AND

IN CONDUIT

(WAREHOUSE FEEDER)

VILLAGE FEEDER 2 (SS131)

IN TUNNEL

IN EXISTING CABLE TRAY

SWITCHYARD FEEDER(SS42, SS133)

VILLAGE FEEDER 2 (SS131)&

S

IT

E P

L A

N V

IL

L A

G E S

W

IT

C H

Y A

R D F

E E

D E

R

C O

N D

U

IT

R

O U

T

IN

G R

E M

O V

A L

SITE PLAN - VILLAGE & SWITCHYARD FEEDER REMOVAL

D

K W

O N

G

W C

P -1 .0

-6 -9 -D -4

/1

Q - 2-78/28.1

Q - 2-56/2.3

Q - 2-56/14.4

Q - 2/8397

Q - 2-79/725.2

Q - 2/828B.8

Q - 2/842F.2

Q - 2/828A.5

Q - 2/828E.5

Q - 2/8280.8

Q - 2/829.6

Q - 2/716.1

DRAWING NO.

MULTI LEVEL WATER INTAKE VALVE ACTUATOR PLAN

WIRING DIAGRAM - GENERAL POWER

ELECTRICAL PYLON CONDUIT LAYOUT SECTIONS

SPREAD ROOM ARANGEMENT

ARRANGEMENT IN SPREAD ROOM AND TELEPHONE ROOM

POWER WIRING DETAILS - ELEV. 580.0

CABLE TUNNEL - ELECTRICAL INSTALLATION CABLE TRAYS

POWER WIRING PLAN - ELEV. 580.0 UNITS NOS 4,5,6

POWER WIRING DETAILS - ELEV 580.0

POWER WIRING DETAILS - ELEV. 580.0

POWER WIRING PLAN - ELEV. 595.0, UNITS 1 THRU 6

TITLE

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/8 /2

DRAWING PLOT SIZE: ANSI E DATE AND TIME PLOTTED: 1/8/2016 9:56:45 AM BY USERNAME: g2hdcclg Chuck Gierek SHEET NAME: ED100

D E

S

IG

N F

IL

E n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

E V

E N R

M

IL

E S P .E

A N

S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

N A

S H

V

IL

L E T

E N

N E

S S

E E

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

S T

A T

IO

N S

E R

V

IC

E U

P G

R A

D E

P O

W E

R H

O U

S E

C U

M B

E R

L A

N D R

IV

E R

W O

L F C

R E

E K D

A M

W C

P .0

E

D

X X

X .d g n

/1

/2

G

H D

C C

L G

A B

D U

L S

A W

A B

W C

P -1 .0

-6 -9 -D -4

/1

P

O W

E R

H O

U S

E A

R R

A N

G E

M E

N T P

L A

N

ED101

N

12"0 5' 10' 15'

A

Scale: „" = 1'-0"

R E

M O

V A

L

33'-2"

23'-0"

"8 71'-9

UNIT NO. 3

EL. 580.0

GENERATOR ROOML UNITC

L

IN

E O

F C

O N

T R

A C

T

IO

N J

O

IN

T

L

IN

E O

F C

O N

T R

A C

T

IO

N J

O

IN

T

UNIT NO. 1

RAILING

CONCRETE

U N

IT

A

IR

C

O N

D

COMPRESSOR

KITCHEN

CORRIDOR

RECORDS

SHELVING

STEEL

& SHELF

HOOK STRIP

JAN.NO. 1

ELEV.

R

U P

R

D N

D .F

S W

IT

C H

B O

A R

D

C S

TABLE

REFERENCE

DESK

OPERATOR'S

LIGHTING MAY BE EXTENDED FOR ADDITIONAL PANELS

CEILING FURRING TO BE ARRANGED SO THAT SWITCHBOARD

NOTE:

CONTROL ROOM

BENCHBOARD "MB"

PLASTER SOFFIT ABOVE

PLATE GLASS PARTITION

PAVER TILE FLOOR

SECTIONS

REMOVABLE SLAB

R A

IL

IN

G R

E M

O V

A B

L E

C

G E

N E

R A

T O

R R

O O

M

L

IN

E O

F C

O N

T R

A C

T

IO

N J

O

IN

T

SOLE PL

EL. 595.0

304 305

S W

IT

C H

B O

A R

D

A S

SWITCHBOARD "MS"

STATION SERVICE SWITCHGEAR "SS"

NO. 2

LTG. TRANSF.

NO. 1

LTG. TRANSF.

LTG. SWGR. "LS"

INSTRUMENT ROOM

ROOM

DARK 318

NO. 4

R

D N

R

U P

313 315

ROOM

FAN

DN.

D N

E L .0

EL. 594.0

SLOPE

S L

O P

E

SINK

WATERTIGHT HATCH COVER

GATE SLOT COVER

D.F.

BRONZE GATE

PAVER TILE FLOOR

DRAINS

NO. 2

NO. 3

DN. 24 R

UP 26 R

UNIT NO. 2

EL. 595.0

SWITCHGEAR ROOM

U P

R

EL. 595.0

144321 5 6 2

1 17

7 8 2 18 9 10 2

F

E

D

C

B

A

TOIL.

REFERENCE DRAWINGS:

DRAWING NUMBER

NOTES:

& ED208

SEE SHEET ED207

FLOOR PLAN UNITS 1-3 - EL. 580.0 AND EL. 595.0- REMOVAL

16 '-5"W x 28'H

POWERHOUSE MAIN DOOR

FRONT ACCESS

5'-9"

28'-4"

WALKWAY PAD

EXISTING

7 '-9"D x 9'-8"W x 8'H

ELEVATOR

V-1 BOARD

CABLE TRAY

EXISTING SUMP PUMP

SEE NOTE 6

SEE NOTE 6

SEE NOTE 6 SEE NOTE 6

KEY PLAN

Q - 2-56/14.4

Q - 2/8397

Q - 2-79/725.2

Q - 2/828B.8

Q - 2/842F.2

Q - 2/828A.5

Q - 2/828E.5

Q - 2/8280.8

Q - 2/829.6

Q - 2/716.1

Q - 2 / 731.4

ELECTRICAL PYLON CONDUIT LAYOUT SECTIONS

SPREAD ROOM ARANGEMENT

ARRANGEMENT IN SPREAD ROOM AND TELEPHONE ROOM

POWER WIRING DETAILS - ELEV. 580.0

CABLE TUNNEL - ELECTRICAL INSTALLATION CABLE TRAYS

POWER WIRING PLAN - ELEV. 580.0 UNITS NOS 4,5,6

POWER WIRING DETAILS - ELEV 580.0

POWER WIRING DETAILS - ELEV. 580.0

POWER WIRING PLAN - ELEV. 595.0, UNITS 1 THRU 6

EL. 595.0 UN. 1, 2 & 3

POWERHOUSE ARRANGEMENT PLAN

TITLE

E L .0

.0 U

N ,2 ,3

(SEE NOTE 7)

OPENING IN FLOORTO REMAIN

BUS DUCT 2'-1"x2-1/2"

(SEE NOTE 5)

OPENING IN FLOORTO REMAIN

BUS DUCT 2'-1"x2-1/2"

D

K W

O N

G

ON THE TILE FLOOR INSIDE THE POWERHOUSE WITH THE COR .

8. THE CONTRACTOR MUST COORDINATE THE MAXIMUM LOAD ALLOWABLE

7. SEE REFERENCE DRAWINGS FOR CABLE AND CONDUCTOR ROUTINGS.

6. CONTRACTOR STORAGE AREA DURING CONSTRUCTION.

EXISTING BUS DUCT WITH STEEL PLATE AND MATCH THE FINISHED FLOOR.

5. CLOSE PERMANENTLY AND COVER AFTER REMOVAL OF

SEE ONE- LINE AND CABLE AND CONDUIT SCHEDULES REMOVAL DRAWINGS.

4. FOR CLARITY NOT ALL POWER AND CONTROL CABLES TO BE REMOVED ARE SHOWN.

UNLESS OTHERWISE NOTED.

OF ALL THE EXISTING LOADS AND DEVICES WHEN NEW EQUIPMENT ARE INSTALLED

OF ANY EXISTING EQUIPMENT AS NECESSARY TO MAINTAIN CONTROL FUNCTIONALITY

3. CONTRACTOR SHALL VERIFY CONTROL WIRING AND TERMINATIONS PRIOR TO REMOVAL

2. EXISTING CONDUITS NOT SHOWN FOR CLARITY.

1. BOLD INDICATES EQUIPMENT TO BE REMOVED.

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/8 /2

DRAWING PLOT SIZE: ANSI E DATE AND TIME PLOTTED: 1/8/2016 9:58:08 AM BY USERNAME: g2hdcclg Chuck Gierek SHEET NAME: ED101

D E

S

IG

N F

IL

E n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

E V

E N R

M

IL

E S P .E

A N

S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

N A

S H

V

IL

L E T

E N

N E

S S

E E

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

S T

A T

IO

N S

E R

V

IC

E U

P G

R A

D E

P O

W E

R H

O U

S E

C U

M B

E R

L A

N D R

IV

E R

W O

L F C

R E

E K D

A M

W C

P .0

E

D

X X

X .d g n

/1

/2

G

H D

C C

L G

A B

D U

L S

A W

A B

W C

P -1 .0

-6 -9 -D -4

/1

P

O W

E R

H O

U S

E A

R R

A N

G E

M E

N T P

L A

N

ED102

12"0 5' 10' 15'

" = 1'-0"8 1Scale:

R E

M O

V A

L

REFERENCE DRAWINGS:

DRAWING NUMBER TITLE

Q - 2 / 731a.1

EL. 595.0 UN. 4, 5 & 6

POWERHOUSE ARRANGEMENT PLAN

L

IN

E O

F C

O N

T R

A C

T

IO

N J

O

IN

T

L

IN

E O

F C

O N

T R

A C

T

IO

N J

O

IN

T

UNIT NO. 4

EL. 580.0

GENERATOR ROOM

UNIT NO. 5 UNIT NO. 6

EL. 580.0

GENERATOR ROOM

RAILING

CONCRETE

L UNITSC

EL. 607.0

BALCONY

FLOOR OF

8" CONCRETE WALL

UP TO BOTTOM OF BEAM

IRON LADDER

RAILING

CONCRETE

CRANE CAB ABOVE

OUTLINE OF

L UNITSC

EL. 595.0

GRILLE

18"x36"

X X

R

D N

GRILLE

18"x18"

O V

E R S

T A

IR

S C

O N

C P

L A

S

C E

IL

IN

G

NO. 9

16 R

DN.

SLOPE

E L .0

FAN ROOM

GRILLE

18"x36"

VENTILATING SWGR. V2

SWITCHGEAR ROOM

EL. 595.0

RAILING

CONCRETE

FIN. FL.EL. 595.0

R

D N

R

U P

GRILLE

20"x36"

X X

GRILLE

20"x36"

F A

N

ROOM

FAN

FAN #13

S L

O P

E

SLOPE

E L .0

E L .0

DN. 15. R

ROOM

DARK 318

SINK

INSTRUMENT ROOM

NO. 4

TRANSFORMER

STA. SERVICE

L

IN

E O

F C

O N

T R

A C

T

IO

N J

O

IN

T

10 2 110 11 12 2

112 13 14 2 114 15 16 17

A

B

C

D

E

FF

E

NOTES:

BUS DUCT

15KV SEGREGATED

EL. 580.0

GENERATOR ROOM

EL. 580.0

GENERATOR ROOM

SEE NOTE 6

FLOOR PLAN UNITS 4-6 - EL. 580.0 AND EL. 595.0- REMOVAL

N

KEY PLAN

10 2 110 11 12 2

112 13 14 2 114 15 16 17

FLOOR

4'-11"x4'-11" OPENING IN

SWITCHES "T3"

STA. SERVICE SELECTOR

FLOOR

4'-11"x4'-11" OPENING IN

SWITCHES "T2"

STA. SERVICE SELECTOR

OPENING IN FLOOR

1'-3"x1'-4 1/2"

E L

.0 U

N ,5 ,6

2" FINISH

SPARE-2"C

MB72-2"C

SS84-2"C

SPARE-2"C

MB73-2"C

SS85-2"C

SEE SHEET ED106

D

K W

O N

G

7. SEE REFERENCE DRAWINGS FOR CABLE AND CONDUCTOR ROUTINGS.

6. CONTRACTOR STORAGE AREA DURING CONSTRUCTION.

AND MATCH THE FINISHED FLOOR GRADE. SEE DRAWING S-501 FOR DETAILS.

5. COVER OPENING AFTER REMOVAL OF EXISTING BUS DUCT WITH CONCRETE COVER

SEE ONE- LINE AND CABLE AND CONDUIT SCHEDULES REMOVAL DRAWINGS.

4. FOR CLARITY NOT ALL POWER AND CONTROL CABLES TO BE REMOVED ARE SHOWN.

UNLESS OTHERWISE NOTED.

OF ALL THE EXISTING LOADS AND DEVICES WHEN NEW EQUIPMENT ARE INSTALLED

OF ANY EXISTING EQUIPMENT AS NECESSARY TO MAINTAIN CONTROL FUNCTIONALITY

3. CONTRACTOR SHALL VERIFY CONTROL WIRING AND TERMINATIONS PRIOR TO REMOVAL

2. EXISTING CONDUITS NOT SHOWN FOR CLARITY.

1. BOLD INDICATES EQUIPMENT TO BE REMOVED.

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/8 /2

DRAWING PLOT SIZE: ANSI E DATE AND TIME PLOTTED: 1/8/2016 9:58:19 AM BY USERNAME: g2hdcclg Chuck Gierek SHEET NAME: ED102

D E

S

IG

N F

IL

E n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

E V

E N R

M

IL

E S P .E

A N

S

P -1 .0

-6 -9 -D -4

/1

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

N A

S H

V

IL

L E T

E N

N E

S S

E E

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

S T

A T

IO

N S

E R

V

IC

E U

P G

R A

D E

P O

W E

R H

O U

S E

C U

M B

E R

L A

N D R

IV

E R

W O

L F C

R E

E K D

A M

/1

/2

G

H D

C C

L G

A B

D U

L S

A W

A B

P O

W E

R H

O U

S E A

R R

A N

G E

M E

N T

ED103

F

E

D

C

B

7 8

1 17

9 105 64321

A

B

C

D

F

E

B

A

18 2

P L

A N E

L .0

U

N

IT

S ,2

R E

M O

V A

L

NO. 6

NO. 3

NO. 1

NO. 4

NO. 8 NO. 8 NO. 8

111 112

SEPARATION JOINT

DRAIN

OVEN

DRYING

OIL PUMP

FIRE DAMPER

16"x24" GRILLE &

PURIFIER

DRAIN

STORE ROOM

S T

O R

A G

E T

A N

K

L U

B R

IC

A T

IN

G O

IL

S T

O R

A G

E T

A N

K

L U

B R

IC

A T

IN

G O

IL

PURIFIER

DRAIN

PUMPS

FIRE DAMPER

16x32" GRILLE &

R

U P

R

D N

DRAIN

SEPTIC TANK EJECTOR

SEWAGE

16"x24" GRILLE

STRAINER

8" TWIN

ELEV.

NOT IN POWERHOUSE CONTRACT

FACE OF DAM STEP

DRAIN

DRAIN

WATER TREATMENT PLANT

DRAIN

DRAIN

U-7

SEPARATION JOINT

DRAINDRAIN

DRAIN

FACE OF DAM

R

U P

C O

N T

R A

C T

IO

N J

O

IN

T

U-3

SUMP

AND

PUMP

T R E N C

H

TANK

PRESSURE

METAL FRAME AND COVER

U P

UP DOWN UP

U P

EL. 567.0

D N

GRATING

TRENCH

TRENCH

D N

UNIT NO. 2 UNIT NO. 3

U-2

SUMP

AND

PUMP

TANK

PRESSURE

TRENCH

TURBINE ROOM EL. 567.0

U-1

SUMP

AND

PUMP

TANK

PRESSURE

U P

DOWNUP

UNIT NO. 1

RAMP

N O

N -S

L

IP

S

U R

F A

C E

R A

M P T

O H

A V

E

E L .0

S T

A T

IO

N S

E R

V

IC

E B

A Y

DRAIN

S W

IT

C H

B O

A R

D

DOWN

T A

N K

S

D R

A

IN

R E

T A

IN

IN

G W

A L L N

O T I

N P

O W

E R

H O

U S

E C

O N

T R

A C

T

C O

N T

R A

C T

IO

N J

O

IN

T

LADDER

DRAFT TUBE GATE

DRAFT TUBE

LADDER TO

S T

O R

A G

E

D R

A

IN

F

IR

E D

A M

P E

R

"x

G R

IL

L E

O

IL

D R

A

IN

T R

A N

S

IL

GRILLE

8"x16"

Co2 STORAGE

16 R

DN.

PIPE

UP 26 R

VALVES

GENERATOR

GRATING

5 R

UP

C O

N T

R A

C T

IO

N J

O

IN

T

C O

N T

R A

C T

IO

N J

O

IN

T

GRATINGGOVERNOR

GRATING

COVER

PUMPS

D N

METAL FRAME AND COVER

TRENCH

C O

N T

R A

C T

IO

N J

O

IN

T

DRAFT TUBE

ACCESS TO

LADDER

GRATING

C O

N T

R A

C T

IO

N J

O

IN

T

U -8

NOTES:

TITLE:DRAWING NUMBER:

REFERENCE DRAWINFGS:

POWER WIRING DETAIL EL. 580. 0Q - 2 / 828E. 5

POWER WIRING DETAIL EL. 580. 0Q - 2 / 828D. 5

POWER WIRING DETAIL EL. 580. 0Q - 2 / 828C. 8

POWER WIRING DETAIL EL. 580. 0Q - 2 / 828B. 8

POWER WIRING PLAN EL. 587. 0 UNITS 4, 5 & 8Q - 2 / 827A. 4

POWER WIRING PLAN EL. 567. 0 UNITS 1, 2 & 3Q - 2 / 827. 7

EL. 567. 0 UNITS 1, 2 & 3

POWERHOUSE ARRANGEMENT PLAN Q - 2 / 729. 5

W C

P .0

E

D

X X

X .d g n

12"0 5' 10' 15'

" = 1'-0-"8 1Scale:

TURBINE ROOM EL. 567.0

TURBINE ROOM EL. 567.0

TURBINE ROOM EL. 567.0

TURBINE ROOM EL. 567.0 TURBINE ROOM EL. 567.0 TURBINE ROOM EL. 567.0

U-8 BOARD

U-1 BOARD U-2 BOARD U-3 BOARD

U-7 BOARD

TURBINE ROOM FLOOR PLAN UNITS 1-3 - EL. 564.0 AND EL. 567.0 - REMOVAL

N

KEY PLAN

5. SEE REFERENCE DRAWINGS FOR CABLE AND CONDUCTOR ROUTINGS.

SEE ONE- LINE AND CABLE AND CONDUIT SCHEDULES REMOVAL DRAWINGS.

4. FOR CLARITY NOT ALL POWER AND CONTROL CABLES TO BE REMOVED ARE SHOWN.

UNLESS OTHERWISE NOTED.

OF ALL THE EXISTING LOADS AND DEVICES WHEN NEW EQUIPMENT ARE INSTALLED

OF ANY EXISTING EQUIPMENT AS NECESSARY TO MAINTAIN CONTROL FUNCTIONALITY

3. CONTRACTOR SHALL VERIFY CONTROL WIRING AND TERMINATIONS PRIOR TO REMOVAL

2. EXISTING CONDUITS NOT SHOWN FOR CLARITY.

1. BOLD INDICATES EQUIPMENT TO BE REMOVED.

C O

N T

IN

U E

D O

N S

H E

E T E

D

D

K W

O N

G

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/8 /2

DRAWING PLOT SIZE: ANSI E DATE AND TIME PLOTTED: 1/8/2016 9:58:30 AM BY USERNAME: g2hdcclg Chuck Gierek SHEET NAME: ED103

D E

S

IG

N F

IL

E n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

E V

E N R

M

IL

E S P .E

A N

S

P -1 .0

-6 -9 -D -4

/1

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

N A

S H

V

IL

L E T

E N

N E

S S

E E

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

S T

A T

IO

N S

E R

V

IC

E U

P G

R A

D E

P O

W E

R H

O U

S E

C U

M B

E R

L A

N D R

IV

E R

W O

L F C

R E

E K D

A M

/1

/2

G

H D

C C

L G

A B

D U

L S

A W

A B

P O

W E

R H

O U

S E A

R R

A N

G E

M E

N T

ED104

12"0 5' 10' 15'

11010

A

11 12 2 112 13

1 17

1615 17

A

B

C

D

F

E

17161514 2 11411 12 2

112 132 11010

F

D

E

B

C

R E

M O

V A

L

NO. 9

NO. 8

NO. 8

NO. 8NO. 8

C O

N T

R A

C T

IO

N J

O

IN

T

113 CFM COMPRESSOR

330 CFM COMPRESSOR

34 CF RECEIVER

SEPARATION JOINT

10.8 CFM COMPRESSOR

"2 17'-9

CEILING

CONTRACT

NOT IN POWER HOUSE

E L .0

F

IN

F

L

R

U P

SEPARATION JOINT

7'-11"

CEILING

DN. 42 R

NO. 10

TANK

PRESSURE

SUMP

AND

PUMP

U-6

TURBINE ROOM EL. 567.0

(CEMENT MORTAR FINISH)

TRENCH

TANK

PRESSURE

METAL FRAME AND COVER

SUMP

AND

PUMP

U-5

UNIT NO. 6

TANK

PRESSURE

AND SUMP

OIL PUMP

GOVERNOR

U-4

U P

U P

DN.

MANUFACTURER

TURBINE

METAL STAIRS BY

UP DN.

GRATING

D N

METAL FRAME AND COVER

TRENCH

UP

U P

DN. UP

U P

EL. 567.0

FIN. FL.

B O

A R

D S

W

D N R

15 R

DN. NO. 11

F

IN

F

L E

L .0

D N

STAIRS

METAL CIRCULAR

C O

N T

R A

C T

IO

N J

O

IN

T

TRENCH

TRENCH

GRATING

D N

GRATING

D N

C O

N T

R A

C T

IO

N J

O

IN

T

UNIT NO. 4 UNIT NO. 5

C O

N T

R A

C T

IO

N J

O

IN

T

NOT IN POWERHOUSE CONTRACT

FACE OF DAM

DRAIN

96 CF RECEIVER

275 CF RECEIVER DRAIN

DRAIN

DRAIN

U -9

14 2

NOTES:

REFERENCE DRAWINGS:

DRAWING NUMBER TITLE

EL. 567.0 UN. 4, 5 & 6

POWERHOUSE ARRANGEMENT PLANQ - 2 / 729A

W C

P .0

E

D

X X

X .d g n

FIN. FL. EL. 567.0 FIN. FL. EL. 567.0 FIN. FL. EL. 567.0

TURBINE ROOM FLOOR PLAN UNITS 4-6 - ELEVATION 567.0 - REMOVAL

U-4 BOARD U-5 BOARD U-6 BOARD

U-9 BOARD

COVER

AND

FRAME

METAL

SUMP PUMPS

N

KEY PLAN 5. SEE REFERENCE DRAWINGS FOR CABLE AND CONDUCTOR ROUTINGS.

SEE ONE- LINE AND CABLE AND CONDUIT SCHEDULES REMOVAL DRAWINGS.

4. FOR CLARITY NOT ALL POWER AND CONTROL CABLES TO BE REMOVED ARE SHOWN.

UNLESS OTHERWISE NOTED.

OF ALL THE EXISTING LOADS AND DEVICES WHEN NEW EQUIPMENT ARE INSTALLED

OF ANY EXISTING EQUIPMENT AS NECESSARY TO MAINTAIN CONTROL FUNCTIONALITY

3. CONTRACTOR SHALL VERIFY CONTROL WIRING AND TERMINATIONS PRIOR TO REMOVAL

2. EXISTING CONDUITS NOT SHOWN FOR CLARITY.

1. BOLD INDICATES EQUIPMENT TO BE REMOVED.

C O

N T

IN

U E

D O

N S

H E

E T E

D

P L

A N E

L .0

U

N

IT

S ,5

D

K W

O N

G

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/8 /2

DRAWING PLOT SIZE: ANSI E DATE AND TIME PLOTTED: 1/8/2016 9:58:41 AM BY USERNAME: g2hdcclg Chuck Gierek SHEET NAME: ED104

D E

S

IG

N F

IL

E n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

E V

E N R

M

IL

E S P .E

A N

S I E

G

H D

C C

L G

A B

D U

L S

A W

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

N A

S H

V

IL

L E T

E N

N E

S S

E E

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

S T

A T

IO

N S

E R

V

IC

E U

P G

R A

D E

P O

W E

R H

O U

S E

C U

M B

E R

L A

N D R

IV

E R

W O

L F C

R E

E K D

A M

/1

/2

C

C

BEAMS SHOWN ARE BEAMS FOR FLOOR AT EL. 595.0

NO-4FLOOR EL. 580.0

B

VENTILATION DUCT

B

NO-1

U P

D O

W N

16 1/2"x16"

OFFSET IN

WALL

BUILDING CONTRACTION JOINTS. MAKE NECESSARY PROVISIONS IN BUS

FOR POSSIBLE BUILDING MOVEMENT AT THESE POINTS.

BEAM DEPTHS MESA-

URED FROM TOP OF

STRUCT. SLAB

2" FINISH

6" FILL

5 1/2" SLAB

EL. 595.0

15"x16 1/2" OPEN-

CONTROL CABLE

TUNNEL

EL. 580.0

2" FINISH

6" FILL

5 1/2" SLAB

600V., 2000 AMP.

A

EL. 546.5

H A

N D

R A

IL

E L .3

3600V., 2000

EL. 550.0

18"x17"

OPENING

IN WALL

CABLE TAP

BOX

SEE DWG.

Q-21826B

STATION SERVICE

GENERATOR

ALL BEAM DEPTHS MEASURED

FROM TOP OF STRUCT. SLAB

2" FINISH

6" FILL

5 1/2" SLAB

600V. 2000 AMP.

40 1/2" x15" BEAM

(LOWEST BEAM ALONG DUCT RUN)

2" FINISH

5" FILL

5 1/2" SLAB

EL. 580.0

CONTROL CABLE

TUNNEL

7 1/2"x25" OPEN-

ING IN FLOOR

VENTILATION DUCT

EL. 595.0

EL. 583.62

CABLE

TUNNEL

NO. 2

CABLE

TUNNEL

NO. 1 CONTROL

CABLE

TUNNEL

FIN. FLOOR EL. 595.0

FIN. FLOOR EL. 580.0 FLOOR FLANGE

4"x4" CONC. CURB

CLEARANCE

FIN. FLOOR EL. 564.0

17"x18" OPENING

IN FLOOR AND RAMP

SS PENSTOCK

STA. SERV. TUR.

& GAV. TERM. CAB.

IN WALL

OPENING

EL. 564.0 CABLE TAP BOX 6" OFFSET

STA. SERVICE

GENERATOR

SEE DWG. Q-2/826B

CABLE TAP BOX

STAIR

WALL

2" FINISH

6" FILL

24" SLAB

A

9'-8

3 4 4 1/2 5 6 6 1/2 7 8 8 1/2 9 10 10 1/2 12 12 1/2 13

F

E

F

E

C

D

B

E F

F E D C B

F

E

R E

M O

V A

L

S S G

E N

E R

A T

O R B

U S D

U C

T

G E

N E

R A

L A

R R

A N

G E

M E

N T

W C

P .0

E

D

X X

X .d g n

ED105

REFERENCE DRAWINGS:

DRAWING NUMBER TITLE

NOTES:

W C

P -1 .0

-6 -9 -D -4

/2

VENTILATION DUCT

FLOOR EL. 580.0

BEAMS SHOWN ARE BEAMS FOR FLOOR AT EL. 595.0

PLAN EL. 580.0

C

15"x16 1/2" OPEN-

CONTROL CABLE

TUNNEL

EL. 580.0

2" FINISH

6" FILL

5 1/2" SLAB

STRUCT. SLAB 5 1/2" SLAB

EL. 595.0

BEAM DEPTHS MESA-

URED FROM TOP OF

2" FINISH

6" FILL

BUILDING CONTRACTION JOINTS. MAKE NECESSARY PROVISIONS IN BUS

FOR POSSIBLE BUILDING MOVEMENT AT THESE POINTS.

U P

D O

W N

16 1/2"x16"

OFFSET IN

WALL

A

EL. 546.5

H A

N D

R A

IL

600V., 2000

E L .3

EL. 550.0

18"x17"

OPENING

IN WALL

CABLE TAP

BOX

SEE DWG.

Q-21826B

STATION SERVICE

A

ALL BEAM DEPTHS MEASURED

FROM TOP OF STRUCT. SLAB

2" FINISH

6" FILL

5 1/2" SLAB

EL. 595.0

7 1/2"x25" OPEN-

ING IN FLOOR

VENTILATION DUCT

CONTROL CABLE

TUNNEL

2" FINISH

5" FILL

5 1/2" SLAB

EL. 580.0

(LOWEST BEAM ALONG DUCT RUN)

17"x18" OPENING

IN FLOOR AND RAMP

FIN. FLOOR EL. 564.0

SS PENSTOCK

STA. SERV. TUR.

& GAV. TERM. CAB.

IN WALL

OPENING

CABLE TAP BOX 6" OFFSET

CABLE TAP BOX

SEE DWG. Q-2/826B

STAIR

WALL

2" FINISH

6" FILL

24" SLAB

STA. SERVICE

GENERATOR

FLOOR FLANGE

4"x4" CONC. CURB

CLEARANCE

FIN. FLOOR EL. 580.0

CONTROL

CABLE

TUNNEL

FIN. FLOOR EL. 595.0

CABLE

TUNNEL

NO. 2

CABLE

TUNNEL

NO. 1

EL. 583.62 SECTION C-C

PLAN EL. 550.0

SECTION B-B

SECTION A-A

(SEE NOTE 2)

UP TO "SS" SWBD.

(SEE NOTE 2)

ING IN FLOOR

600V BUS DUCT EL.580.0

600V BUS DUCT EL.580.0

TRANSFORMER

STATION SERVICE

"SS" SWGR.

EL. 580.0

UP TO

600V STATION SERVICE GEN. BUS DUCT

TRANSFORMER

KITCHEN

(SEE NOTE 2)

TRANSF.

SERVICE

STATION

UP TO

SHAFT

ELEVATOR

Q - 2/828A.5

Q - 2/828E.5

Q - 2/8280.8

Q - 2/829.6

Q - 2 / 792.1

Q - 2 / 797.2

POWER WIRING PLAN - ELEV. 580.0 UNITS NOS 4,5,6

POWER WIRING DETAILS - ELEV 580.0

POWER WIRING DETAILS - ELEV. 580.0

POWER WIRING PLAN - ELEV. 595.0, UNITS 1 THRU 6

ONE LINE DIAGRAM LS BUS

GENERAL ARRANGEMENT

SS GENERATOR BUS DUCT

SS114, SS115, SS122, SS123, SS124, SS41 (SEE NOTE 3)

SS33, SS34, SS101, SS102, SS103, SS104, SS105, SS106, SS121

SS11, SS12, SS13, SS14, SS15, SS16, SS24, SS25, SS32, SS31

IN CABLE TUNNEL (TYP.)

EXISTING CABLE TRAYS

D

K W

O N

G

(SEE NOTE 3)

AS38, AS68, AS69, RAG4, MB72, MB73, MR73

MR71, SS61, SS71, SS81,SS62, SS63, SS83, LS29

SS21, SS23, SS42, SS111, SS113, SS131, SS133, SS132

ROUTINGS.

SEE REFERENCE DRAWINGS FOR CABLE AND CONDUCTOR

4. REMOVE EXISTING DESIGNATED CABLES AND CONDUCTORS.

FOR CABLE AND CONDUCTOR ROUTINGS.

3. SEE CABLE AND CONDUCTOR SCHEDULE AND REFERENCE DRAWINGS

SEE DRAWING S-501 FOR DETAILS.

CONCRETE COVER AND MATCH THE FINISHED FLOOR GRADE.

2. COVER OPENING AFTER REMOVAL OF EXISTING BUS DUCT WITH

1. BOLD INDICATES EQUIPMENT TO BE REMOVED.

(LOWEST BEAM ALONG DUCT RUN)

40 1/2" x15" BEAM

S-501

D

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/8 /2

DRAWING PLOT SIZE: ANSI E DATE AND TIME PLOTTED: 1/8/2016 9:58:52 AM BY USERNAME: g2hdcclg Chuck Gierek SHEET NAME: ED105

D E

S

IG

N F

IL

E n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

E V

E N R

M

IL

E S P .E

A N

S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

N A

S H

V

IL

L E T

E N

N E

S S

E E

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

S T

A T

IO

N S

E R

V

IC

E U

P G

R A

D E

P O

W E

R H

O U

S E

C U

M B

E R

L A

N D R

IV

E R

W O

L F C

R E

E K D

A M

W C

P .0

E

D

X X

X .d g n

/1

/2

G

H D

C C

L G

A B

D U

L S

A W

A B

W C

P -1 .0

-6 -9 -D -4

/2

R E

M O

V A

L

K V S

T A

T

IO

N S

E R

V

IC

E S

W

IT

C H

G E

A R

EL. 610.83

EL. 595.0

FRONT ELEVATION

1500 KVA 3 STATION SERVICE

TRANSF. 13,200/480 VOLTS

15 KV STATION SERVICE BUS

480 VOLT BUS TO

SWITCHGEAR SS

SEE DWGS Q-2/793

& Q-2/797

B

B

SWITCHGEAR T2

DOORS OPEN

12 1/2 13

FOR SECONDARY LEADS

BEAM

EL. 610.83

EL. 595.0

BOX CONTAINING 1 STA. SERVICE

SECTION B-B

TRANSFORMERTERMINAL BOARD, 4

POLE WITH SHORT

CIRCUITING STRIPS

SWITCHGEAR T3

DOORS CLOSED

ED106

REFERENCE DRAWINGS:

DRAWING NUMBER TITLE

Q - 2 / 790.2

SECTIONAL UN. T2, T3, SS TRANSFORMER

15 KV STATION SERVICE SWITCHGEAR

S E

C T

IO

N A

L U

N T ,T

S

S T

R A

N S

O R

M

1 1/4" CONDUIT TO CABLE TUNNEL

9'-0" 9'-0" 4'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0"

58'-0"

2"± 71

2"±

24'-7"8'-0"20'-6"

NOTES:

STATION SERVICE TRANSFORMER

15 KV STATION SERVICE BUS

OPENING IN FLOOR

OPENING IN FLOOR

WALL

11'-4"

5'-2"

5'-2" 3'-3"

WALL

SELECTION SWITCH

STATION SERVICE

N

KEY PLAN

SEE REFERENCE DRAWINGS FOR CABLE AND CONDUCTOR ROUTINGS.

5. REMOVE CABLES AND CONDUCTORS TO THE FIRST POINT OF TERMINATION.6.

SEE ONE- LINE AND CABLE AND CONDUIT SCHEDULES REMOVAL DRAWINGS.

4. FOR CLARITY NOT ALL POWER AND CONTROL CABLES TO BE REMOVED ARE SHOWN.

3. SEE DRAWING E-106 FOR NEW EQUIPMENT INSTALL.

UNLESS OTHERWISE NOTED.

OF ALL THE EXISTING LOADS AND DEVICES WHEN NEW EQUIPMENT ARE INSTALLED

OF ANY EXISTING EQUIPMENT AS NECESSARY TO MAINTAIN CONTROL FUNCTIONALITY

2. CONTRACTOR SHALL AS- BUILT CONTROL WIRING AND TERMINATIONS PRIOR TO REMOVAL

1. BOLD INDICATES EQUIPMENT TO BE REMOVED.

D

K W

O N

G

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/8 /2

DRAWING PLOT SIZE: ANSI E DATE AND TIME PLOTTED: 1/8/2016 9:59:03 AM BY USERNAME: g2hdcclg Chuck Gierek SHEET NAME: ED106

D E

S

IG

N F

IL

E n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

E V

E N R

M

IL

E S P .E

A N

S I E

G

H D

C C

L G

A B

D U

L S

A W

P -1 .0

-6 -9 -D -4

/2

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

N A

S H

V

IL

L E T

E N

N E

S S

E E

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

S T

A T

IO

N S

E R

V

IC

E U

P G

R A

D E

P O

W E

R H

O U

S E

C U

M B

E R

L A

N D R

IV

E R

W O

L F C

R E

E K D

A M

/1

/2

A

EL. 595.0

EL 5950

CABLE PIT

1'-8 1/2"

2000 5-5 CT'S

480-120V PT'S

LIMIT OF BUS DUCT DOOR O

SEE DWG Q-2/797

ENCLOSED BUS.

600V, 2000A, 3 PHASE

ITEM

NO.

USE VOLTAGE

RATING

INT. CAP.

NEMA

FRAME

RATING

NO.

POLES

TRIP

RATING

TERMINAL

& CABLE

SIZE

MAN. OR

ELECT

OPERATED

50,000

50,000

50,000

50,000

50,000

50,000

50,000

50,000

50,000

50,000

50,000

50,000

75,000

75,000

75,000

50,000

50,000

50,000

50,000

50,000

50,000

50,000

50,000

50,000

50,000

50,000

50,000 3

3 800

800 300

500 MAN.

6-#4/0

6-#4/0

3-#4/0

3-#4/0

6-500MCM

3-500MCM

3-500MCM

3-400MCM

3- #4/0

3 #4/0

BUS

BUS

BUS

6- #4/0

6- #4/0

6- #4/0

3- #4/0

3- #4/0

6-500MCM

3-500MCM

3-500MCM

3-400MCM

3- #4/0

3-400MCM

3 #4/0

MAN.

MAN.

MAN.

MAN.

MAN.

MAN.

MAN.

MAN.

MAN.

MAN.

MAN.

ELECT.

ELECT.

ELECT.

MAN.

MAN.

MAN.

MAN.

MAN.

MAN.

MAN.

MAN.

MAN.

MAN.

MAN.

MAN.

STATION SERVICE BUS GRD. RELAY WITH AMBER IND. LIGHT

AMMETER-TRANSFER SWITCH

VOLTMETER-TRANSFER SWITCH

AMMETER-STATION SERVICE TRANSFORMER (0-2000A)

VOLTMETER-STATION SERVICE TRANSFORMER (0-600V)

AMMETER-STATION SERVICE GENERATOR (0-2000A)

VOLTMETER-STATION SERVICE GENERATOR (0-600V)

BUS TRANSITION SPACE

SWITCHYARD FEEDER NO 2 A.C.B.

CRANE FEEDER A.C.B.

VILLAGE FEEDER NO.2 A.C.B.

SWITCHGEAR "U9" & "V2" FEEDER NO.2 A.C.B.

SWITCHGEAR "U8" FEEDER NO.2 A.C.B.

LIGHTING TRANSFORMER NO.2 A.C.B.

SWITCHGEAR "U7" & "V1" FEEDER NO.2 A.C.B.

DAM FEEDER NO.2 A.C.B.

HEADGATE FEEDER NO.2 A.C.B.

SWITCHGEAR "U3" & "U6" FEEDER NO.2 A.C.B.

SWITCHGEAR "U2" & "U5" FEEDER NO.2 A.C.B.

SWITCHGEAR "U1" & "U4" FEEDER NO.2 A.C.B.

STATION SERVICE TRANSFORMER A.C.B.

BUS TIE A.C.B.

STATION SERVICE GENERATOR A.C.B.

SPARE A.C.B.

VILLAGE FEEDER NO.1 A.C.B.

SWITCHGEAR "U9" & V2" FEEDER NO.1 A.C.B.

SWITCHGEAR "U8" FEEDER NO.1 A.C.B.

LIGHTING TRANSFORMER NO.1 A.C.B.

SWITCHGEAR "U7" & "V1" FEEDER NO.1 A.C.B.

DAM FEEDER NO.1 A.C.B.

HEADGATE FEEDER NO.1 A.C.B.

SWITCHGEAR "U3" & "U6" FEEDER NO.1 A.C.B.

SWITCHGEAR "U2" & "U5" FEEDER NO.1 A.C.B.

SWITCHGEAR "U1" & "U4" FEEDER NO.1 A.C.B.

LIST OF EQUIPMENT

CIRCUIT BREAKER

6-#4/0

SEE SPECS

SWITCHYARD.1 FEEDER NO.1 A.C.B.

5-200 VA 480-120V POT. TRANSFS.(3 IN GEN. ACB COMPT. AND 2 IN TRANSF. ACB COMPT.

3-2000-5A CT'S (IN GENERATOR ACB COMPT.)

3-10-54 AUXILIARY CTS (IN TRANSTFS. A.C.B. COMPT.)

D-C PANELBOARDS CONTAINING 15-250V, 2P, 50A FRAME BREAKERS (NOS. 40-54 INCL.) & 3-250V, 2P, 100A

FRAME FEEDER BREAKERS 9NOS. 39,55,&56) FOR TRIP RATING AND USE SEE DWG. Q-2/833

3 2000-5-5ACT'S (IN TRANSF. A.C.B. COMPT.)

W C

P .0

E

D

X X

X .d g n

REFERENCE DRAWINGS:

ED201

SECTION A-A

1 4 7 10

2 5 8 11

3 6 9 12

PANEL NO. 1 PANEL NO. 2 PANEL NO. 3 PANEL NO. 4

33 34

29 30

13 14 15

33 34

31 32

16 19 22 25

17 20 23 26

18 21 24 27

PANEL NO. 9 PANEL NO. 10 PANEL NO. 11 PANEL NO. 12 PANEL NO. 13

SPACE FOR TELEPHONE. TO BE

FURNISHED AND MOUNTED

BY GOVERNMENT

STATION SERVICE GENERATOR

A.C.B. ELECTRICALLY OPERATED

BUS TIE A.C.B.

ELECTRICALLY OPERATED

STATION SERVICE TRANSFORMER

A.C.B. ELECTRICALLY OPERATED

PANEL NO. 5 PANEL NO. 6 PANEL NO. 7

FRONT ELEVATION

C STA. GEN.L

BUS DUCT.

SEE DWG

Q-2/797 SEE DWG

BUS DUCT.

C STA. TRANSF.L

PANEL NO. 8

A 7

NOTES:

TITLE:DRAWING NUMBER:

56 &

SCALE: 1"=1'-0"

SCALE: 1"=1'-0"

STATION SERVICE SWITCHGEAR

Q-2/797 AND

Q - 2-56/14.4

Q - 2/8397

Q - 2-79/725.2

Q - 2/828B.8

Q - 2/842F.2

Q - 2/828A.5

Q - 2/828E.5

Q - 2/8280.8

Q - 2/829.6

Q - 2/716.1

Q - 2 / 797.2

Q - 2 / 793. 1

ELECTRICAL PYLON CONDUIT LAYOUT SECTIONS

SPREAD ROOM ARANGEMENT

ARRANGEMENT IN SPREAD ROOM AND TELEPHONE ROOM

POWER WIRING DETAILS - ELEV. 580.0

CABLE TUNNEL - ELECTRICAL INSTALLATION CABLE TRAYS

POWER WIRING PLAN - ELEV. 580.0 UNITS NOS 4,5,6

POWER WIRING DETAILS - ELEV 580.0

POWER WIRING DETAILS - ELEV. 580.0

POWER WIRING PLAN - ELEV. 595.0, UNITS 1 THRU 6

ARRANGEMENT

SS GENERATOR AND SS TRANSFORMER BUS DUCTS GENERAL

STATION SERVICE SWITCHGEAR LAYOUT

6. SEE REFERENCE DRAWINGS FOR CABLE AND CONDUCTOR ROUTINGS.

EXISTING BUS DUCT WITH PROPER MATERIAL TO MATCH THE FLOOR.

5. CLOSE PERMANENTLY AND REPAIR OPENING AFTER REMOVAL OF

WHEN NEW EQUIPMENT'S ARE INSTALLED UNLESS OTHERWISE NOTED.

TO MAINTAIN CONTROL FUNCTIONALITY OF ALL THE EXISTING LOADS AND DEVICES

CONTROL SCHEMATICS AND WIRING'S FOR SWITCHGEAR AND ALL CONTROL CENTERS.

4. REFERENCE DRAWINGS ARE NOT VERIFIED. CONTRACTOR TO VERIFIED EXISTING

SEE ONE- LINE AND CABLE AND CONDUIT SCHEDULES REMOVAL DRAWINGS.

3. FOR CLARITY NOT ALL POWER AND CONTROL CABLES TO BE REMOVED ARE SHOWN.

2. SEE DRAWING E-201 FOR NEW EQUIPMENT INSTALL.

1. BOLD INDICATES EQUIPMENT TO BE REMOVED.

K V S

T A

T

IO

N S

E R

V

IC

E S

W

IT

C H

G E

A R

L A

Y O

U T N

A M

E P

L A

T E

R E

M O

V A

L

D

K W

O N

G

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/8 /2

DRAWING PLOT SIZE: ANSI E DATE AND TIME PLOTTED: 1/8/2016 9:59:15 AM BY USERNAME: g2hdcclg Chuck Gierek SHEET NAME: ED201

D E

S

IG

N F

IL

E n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

E V

E N R

M

IL

E S P .E

A N

S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

N A

S H

V

IL

L E T

E N

N E

S S

E E

N A

S H

V

IL

L E D

IS

T R

IC

T

NASHVILLE DISTRICT

S T

A T

IO

N S

E R

V

IC

E U

P G

R A

D E

P O

W E

R H

O U

S E

C U

M B

E R

L A

N D R

IV

E R

W O

L F C

R E

E K D

A M

/1

/2

G

H D

C C

L G

A B

D U

L S

A W

A B

W C

P -1 .0

-6 -9 -D -4

/2

U

U

L

A Y

O U

T N

A M

E P

L A

T E

W C

P .0

E

D

X X

X .d g n

REFERENCE DRAWINGS:

ED203

FRONT VIEW CONTROL CENTER U7

ITEM

NO

VOLTAGE

RATING INT CAP

NEMA

NO.

POLES

FRAME

RATING

HP

LOAD

& CABLE

TERMINAL

TRIP

RATING SIZE

NEMA COIL

VOLTAGE

USE

SIZE

BUS SUPPLY FDR. NO.1

SPARE COMPARTMENT

GEN. JACKING PUMP MOTOR FDR.

GEN. HSG. HEATER FDR.

GOV. OIL PUMP (#1A-6A) FDR.

TURBINE OIL PUMP MOTOR STARTER

ROOM HEATER (F1-F6) FEEDER

INDICATING LIGHTS FEEDER BREAKER ON SWGR. SS

AUXILIARY RELAY TO OPERATE ALARM ON LOSS OF BUS VOLTAGE

BUS SUPPLY FDR. NO.2

GOV. OIL PUMP (#1B-6B) FDR.

SPARE COMPARTMENT

SPARE COMPARTMENT

INDICATING LIGHTS FEEDER BREAKER ON SWGR. SS

25,000

25,000

15,000

15,000

15,000

15,000

15,000

15,000

3 600 275 - - #4/0

3 600 275 - - #4/0

3 100 15 -- #12

3 100 50 - - #8

3 100 90 - - #4

3 100 90 - - #4

600 100 15 1 440AC #12

600 100 50 - - #8

1 1/2

24 KW

1/2

30 KW

BUS SUPPLY FDR. NO.1

BATT. CHGR. M-G SET NO.1 MOTOR

ELEVATOR FEEDER

BUS SUPPLY FDR. NO.2

25,000

25,000

15,000

15,000

15,000

15,000

15,000

15,000

3 600 500 - - 500 MCM

3 600 500 - - 500 MCM

3 100 15 1 440AC #12

3 100 15 - - #12

3 100 25 1 440AC #12

3 100 15 1 440AC #12

3 100 70 3 440AC #6

3 225 150 - 440AC #1/0

7 1/2

SPARE BREAKER

SPARE COMPARTMENT

INDICATING LIGHTS - NO.6 FEEDER BREAKER ON SWGR.SS

NO.2 SEWAGE PUMP MOTOR STARTER

INDICATING LIGHTS - NO.21 FEEDER BREAKER ON SWGR.SS

600 25,000

15,000

15,000

15,000

15,000

15,000

15,000

120AC

440AC

440AC

#10

#12

#12

#1/0

#1/0

#8

#1/0

SEE ONE LINE DIAGRAM FOR BREAKER NUMBERS

MOTOR STARTERCIRCUIT BREAKER

LIST OF EQUIPMENT - CONTROL CENTERS UI - U6 INCL.

SECTION 1 SECTION 2 SECTION 3

4 9

12 5 10

2 6

13 7 11

EL.567.0

A

MASTER TERMINAL BOARDS

A

MAIN BUS

MASTER

TERMINAL BOARD

CABLE

RACEWAY

INDIVIDUAL

TERMINAL BOARDS

MASTER TERMINAL BOARD

4 9 11 14

17 5 12 15

18 7

EL.567.0

SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5

FRONT VIEW CONTROL CENTER U1

CONTROL CENTERS U2 - U6 SIMILAR

SECTION A-A

R E

M O

V

NOTES:

E-210

TITLE:DRAWING NUMBER:

CONNECTION DIAGRAMS CONTROL CENTERS "U7"Q - 2 / 834S.1

CONNECTION DIAGRAMS CONTROL CENTERS "U1" TO "U8"Q - 2 / 834R.2

SCHEMATIC DIAGRAM CONTROL CENTERS 112 & 119Q - 2 / 834G.4

SCHEMATIC DIAGRAM COINTROL CENTERS "U1" TO "U7"Q - 2 / 834F.5

POWER WIRING DIAGRAM EL. 580.0 & 595.0Q - 2 / 829B.3

POWER WIRING DETAIL EL. 580. 0Q - 2 / 828E. 5

POWER WIRING DETAIL EL. 580. 0Q - 2 / 828D. 5

POWER WIRING DETAIL EL. 580. 0Q - 2 / 828C. 8

POWER WIRING DETAIL EL. 580. 0Q - 2 / 828B. 8

POWER WIRING PLAN EL. 587. 0 UNITS 4, 5 & 8Q - 2 / 827A. 4

POWER WIRING PLAN…