W912NS19B60020003_Amendment__3.pdf

PDF 151 KB Posted

Attached to
Replace Communications Facility Federal contract opportunity
Solicitation number
W912NS-19-B-6002
Issued by
Department of the Army National Guard

About this file

Solicitation Amendment #3

View the file

Other files for this federal contract opportunity

Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ULYB049040

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

The purpose of this amendment is to:

1. Correct the Draw ings and Specifications, see attached changes.

2. Add additional extended description to ABI 4

1. CONTRACT ID CODE PAGE OF PAGES

J 1 4

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 15-Jul-2019

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912NS19B6002

X 9B. DATED (SEE ITEM 11)

14-Jun-2019

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

15-Jul-2019

CODE

USPFO FOR MISSOURI - W912NS

ATTN: MSGT JOSHUA ZACHARIAH,

BASE CONTRACTING OFFICE

705 MEMORIAL DRIVE

ST. JOSEPH MO 64503-9307

W912NS 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

W912NS19B6002

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION SF 30 - BLOCK 14 CONTINUATION PAGE

The following have been added by full text:

AMENDMENT 0003

This addendum forms a part of the Contract Documents and modifies the Bidding Documents with amendment and additions noted below. Acknowledge receipt of this Addendum in the Bid Form. Failure to do so may subject the Proposer to disqualification.

Amendment 0003 consists of descriptive changes and revised drawings listed below. Revised specifications and drawings are also provided with this amendment.

GENERAL CHANGES:

A. General: Disregard any references to work on buildings 52 or 56.

B. General: MC cable is only acceptable in exposed locations.

C. General: Contractor is to provide service and pay usage costs on facility until Beneficial

Occupancy is obtained by the Government.

D. General: ABI for sodding – the contractor shall include costs for watering until sod is established at a minimum. Once the Government takes Beneficial Occupancy, the water usage cost will no longer be on the contractor as the Government will assume all utility costs.

E. General: Refer to attached floor plan for Bldg. 58 demo.

F. General: Refer to attached Geotechnical Report for requirements on engineered fill settle time.

CHANGES TO SPECIFICTIONS:

A. Spec Section 011100: A Salvage Plan is not required.

B. Spec Section 072113: Provide 4 feet of R15 horizontally at perimeter of the heated building slab. Insulation is not required at the mechanical yard slab or any other exterior slabs.

C. Spec Section 081113: There are no maximum duty doors required for this project.

D. Spec Section 105113: Provide 12x18x72 single tier lockers. Each locker area will require

(1) 20"W x 42"L ADA bench (Robinson Steel co. model # RSCADAPLB or approved equal). The remaining benches shall be non-ADA benches 12”W x 36” L (Robinson Steel

co. model # RSCPLB or approved equal).

E. Spec Section 321313: Remove requirement for albedo and 25% recycled concrete aggregate.

CHANGES TO DRAWINGS:

A. DWG CS-101: Disregard note for bike rack and 10’x6’ concrete pad. Item is no longer required.

B. DWG CS-101/C-100: Contractor access to the job site will be from the south along NW

Rosecrans Road, outside of the existing perimeter fencing.

C. DWG CS-501, Detail 5: Reinforcement shown in detail 5/CS501 is applicable to all concrete areas. Dowels are required for “R” panels in accordance with detail 9/CS502

D. DWG S-001: Dead Load: Framing and Roof panel = Actual weight. Collateral Loads:

10psf, except for mechanical, electrical, and communication rooms (i.e. telecom, network operation space) use 15 psf.

E. DWGs S401/402: Length of the 6” slab is 29’-2”. Overall length of the slab for the mechanical yard is 98’-5”.

F. DWG S-501, Detail 9: Add a 6”Hx6”W curb to Section 9/S-501. Curb shall be chamfered on each face. Provided a #4 x 32” LG vertical dowel at 12” OC. lap dowel with grade beam closed tie reinforcing (which has a 2” concrete cover), and extend dowel 5” above top of slab. Provide continuous #4 horizontal bar with 1” clear for top of curb.

Provide a self-adhesive hydrophilic water-stop at the center of curb. Contractor may to use post-installed dowels with adhesive anchors. Follow anchor guidance on DWG S- 002.

G. DWG S-503, Detail 1: Provide compacted fill, vapor retarder and aggregate fill for the 6”, 8”, 9”, and 12” slabs on grade.

H. DWG AF-110, Note 19: Provide epoxy flooring in Vestibule 100 in lieu of LVT and eliminate walk-off mat.

I. DWG AF-110, Note 1: To be furnished and installed by contractor. Provide Model LCS5034, LCS Deluxe Combo, 034 = 3' x 4' board size by Claridge (or approved equal).

J. DWG AF-110, Note 4: To be furnished and installed by contractor. Provide Model 953A, 900 Series Tackboard, 3' x 5' board size by Claridge (or approved equal).

K. DWG AF-110, Note 7: To be furnished and installed by contractor. Provide Model LCS2046R, LCS Deluxe, 034 = 6' x 4' board size, with Map Rail by Claridge (or approved equal). Boards shall span entire length of wall.

L. DWG AF-110, Note 8: To be furnished and installed by contractor. Provide Da-Lite Screen Company, 80” wide x 60” viewing area. Color white (or approved equal)

M. DWG AF-110, Note 20: To be furnished and installed by contractor. Provide Powerheart G5 AED by Cardiac Science (or approved equal).

N. DWG AF-110: Government is furnishing and installing projectors. Contractor is to provide mounting brackets as indicated.

O. DWGs A-201/202 & A-502: Precast Stone is dimensioned on A-502, Detail S-14.

Precast wall is max 3-1/2” thick. Joint layout shall at a minimum match the control joints in the brick. Minimize joints in areas where there is no brick. Attach precast panel to structure per manufacturer’s recommendations. Precast Wainscot is part of base bid on the main communications facility, it is an ABI for the Warehouse portion.

P. DWG A-201/202: Translucent panels shown are not required to be insulated.

Q. DWG A-502, Details H12&J12: Embedded plate is not required.

SECTION 00010 - SOLICITATION CONTRACT FORM

The Issued By organization has changed from

USPFO FOR MISSOURI - W912NS

ATTN: MSGT JOSHUA ZACHARIAH,

BASE CONTRACTING OFFICE

705 MEMORIAL DRIVE

ST. JOSEPH MO 64503-9307

to

139TH BASE CONTRACTING OFFICE

705 MEMORIAL DRIVE

ST. JOSEPH MO 64503-9307

CLIN 0005

The CLIN extended description has changed from:

Additional Parking on West

To:

Additional Parking on West; Five (5) additional Parking Spaces Plus Sidewalk

(End of Summary of Changes)