A-401.pdf

PDF 293 KB Posted

Attached to
Alter/Reconfigure B6922 for Cyber Ops Federal contract opportunity
Solicitation number
W912JB-18-R-8004
Issued by
Department of the Army National Guard

About this file

Updated Specification Drawing A-401

View the file

Other files for this federal contract opportunity

Other files attached to Alter/Reconfigure B6922 for Cyber Ops, newest first.
File Type Posted
MBMV162472_Addendum_2.pdf PDF
SF30_Amend_0005.pdf PDF
RFI_as_of_16_July_2018.pdf PDF
W912JB18R8004-0004_SF_30.pdf PDF
Brand_Name-Sole_Source_Justification_Stanley_Best.pdf PDF
RFI_0003.pdf PDF
MBMV162472_Addendum_1_180629.pdf PDF
W912JB18R8004-0004_Conform_Doc.pdf PDF
RFI_0002.pdf PDF
Site_Visit_Sign_In_Sheet.pdf PDF
AMENDED_SOLICITATION_W912JB18R8004-0003.pdf PDF
RFI_0001.pdf PDF
SF30_W912JB18R8004-0003.pdf PDF
Brand_Name-Sole_Source_Justification_Advantor_CORRECTED_(002).pdf PDF
Brand_Name-Sole_Source_Justification_Monaco_(002).pdf PDF
EXHIBIT_A-B.pdf PDF
Brand_Name-Sole_Source_Justification_Federal_(002).pdf PDF
Site_Visit_Minutes_18R8004_(002).pdf PDF
W912JB-18-R-8004-0002_SF30_PROPOSAL_DUE_TIME_AMENDMENT.pdf PDF
W912JB-18-R-8004-0002_PROPOSAL_DUE_TIME_AMENDMENT.pdf PDF
W912JB-18-R-8004-0001_SITE_VISIT_AMENDMENT.pdf PDF
W912JB-18-R-8004_EXHIBIT_C.pdf PDF
171214_Specs_Vol_3_B3_Battle_Creek_Cyber_Ops.pdf PDF
171214_Specs_Vol_2_B3_Battle_Creek_Cyber_Ops.pdf PDF
W912JB-18-R-8004_RELEASED_SOLICITATION.pdf PDF
171214_-_FULL_SET.pdf PDF
171214_Specs_Vol_1_B3_Battle_Creek_Cyber_Ops_(2).pdf PDF
Show all 27

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R E

F

REF.REF.

PASSAGE

MEN'S

VESTIBULE 106

MEN'S

WOMEN'S

JANITOR

BREAK ROOM

WOMEN'S

LOCKER

MEN'S

LOCKER

PASSAGE

CONFERENCE

ROOM

ACOS / EXEC

OPEN OFFICE

G.O. OFFICE

A

A

A

A

A

106A

110A

4' - 0"

1' - 5 1/2"

4' - 6" 3' - 11 1/4"

6' - 5 7/8" 5' - 3 3/4" 21' - 2" 17' - 5 3/4" 6' - 4 7/8" 8' - 5 1/4"

/8

/4

/4

/2

5' - 3 5/8"

/4

11' - 9 5/8" 5' - 5 5/16" 3' - 4 7/8" 3' - 4 7/8" 3' - 4 7/8" 3' - 4 1/4" 3' - 9 11/16" 3' - 4 7/8" 3' - 4 7/8" 3' - 4 7/8" 5' - 0"

11' - 9 5/8"

/8

SA6

SA3

FC3

SA3

SA6SA6

SA6

SA6SA6

SA6

SA3

SA3

SA3

SA3

SA3 FC3 FC3 SA3 SA3

SA6

FC3

SA6

FC3

A-401

A-401

A-401

A-401

A-4021

GB-2

GB-1

GB-3

TPD

3' - 1" 3' - 1" 3' - 1" 5' - 0"

GB-1

GB-3

TPD

5' - 0" 3' - 1" 3' - 1"

SND

GB-2

TPD

SND

TPD

SNDTPDTPDTPDURS

PTD PTD PTD

PTD

SDSDSDSDSDSDSD

FSS

VSC

VSC

RH

FSS

VSC

VSC

RH

FSS

VSC

VSC

RH

FSS

VSC

VSC

RH

FSS

VSC

VSC

RH

PART PART

EWC

4.136 4.137

4.106

4.1364.136

4.108

A-402

A-402

A-402

A-301

A-301

4.1084.108

4.1104.110

TYP.

3' - 0" CLR. 1' - 6"

FSS

VSC

VSC

RH

TYP.

3' - 0" CLR.

FSS

VSC

VSC

RH

SA3

A-602 TYP

A-402

FC3

FC3

1' - 5 1/2"

2' - 10 1/2" 2' - 10 1/2" 2' - 10 1/2" 3' - 0 1/2" 3' - 1" 3' - 1" 5' - 1" 1' - 6" 1' - 6" 5' - 1" 3' - 1"

1' - 6" 3' - 0" 3' - 0" 3' - 0"3' - 0" 3' - 0" 3' - 0" 3' - 0" 1' - 6"

4.1274.127

4.128

A-402

4.129

FC3

120"

FSS FSS

FSS

GB-1

GB-3

MIR2

SA6

4.136

4.136

4.136

4.136

4.137 4.136

4.106

4.106

4.106

4.106

FD = FLOOR DRAIN (PITCH FLOOR TO DRAIN)

EWC = ELECTRIC WATER COOLER

FSS = FOLDING SHOWER SEAT

GB1 = GRAB BAR (42" L. x 33" A.F.F.)

GB2 = GRAB BAR (36" L. x 33" A.F.F.)

GB3 = GRAB BAR (18"" L. x 39" A.F.F.)

MS = MOP STRIP

MIR1 = MIRROR (2'-0"w. x 4'-0"h.)

MIR2 = MIRROR (2'-6"w. x 5'-0"h.)

PTD = PAPER TOWEL DISPENSER/DISPOSAL (GFCI)

PART = TOILET PARTITION

RH = ROBE HOOKS (3 HOOKS)

SCR = SHOWER CURTAIN ROD

SD = LIQUID SOAP DISPENSER (GFCI)

SND = SANITARY NAPKIN DISPOSAL UNIT

TPD = TOILET PAPER DISPENSER (GFCI)

URS = URINAL SCREEN

VSC = VINYL SHOWER CURTAIN

TOILET ROOM ACCESSORY GENERAL NOTES:

1. LAVATORIES IN TOILET ROOM ARE SOLID SURFACE COUNTERTOPS WITH

UNDERCOUNTER MOUNTED BOWLS, BACKSPLASH SHALL BE INTEGRAL

WITH COUNTERTOP.

2. PROVIDE BLOCKING IN WALLS FOR ALL WALL MOUNTED ACCESSORIES.

3. ALL DOORS AND DRAWERS IN CASEWORK TO HAVE LOCKS AND KEYS.

4. ALL EXPOSED SURFACES OF MILLWORK TO BE P. LAMINATE ON 3/4" PART. BD.,

TYPICAL, UNLESS NOTED OTHERWISE.

5. PROVIDE MOISTURE- AND MOLD-RESISTANT GYPSUM BOARD, AND TILE

BACKING GYPSUM BOARD AS SPECIFIED AND AS REQUIRED BY THE BUILDING

CODE.

6. SEE "ARCHITECTURAL FINISH LIST" IN SPECIFICATIONS FOR MATERIAL

INFORMATION.

7. SEE SHEET A-602 FOR "FINISH" ABBREVIATIONS.

8. SEE SHEET A-121 FOR "CEILING FINISH" ABBREVIATIONS.

9. SEE DETAIL 8/A-401 FOR ALL TOILET ACCESSORY MOUNTING HEIGHTS.

10. ALL TOWEL PINS MOUNTED AT 6' AND 3' ABOVE FINISHED FLOOR UNLESS

NOTED OTHERWISE.

11. VERIFY WALL DIMENSIONS WITH LOCKER MANUFACTURER PRIOR TO

CONSTRUCTION.

TOILET ACCESSORY KEY

M A

X

"M

A X

MIN

1'-3"

(URS)

URINAL

URINAL

@ NON-ADA

ACCESSIBLE

@ ADA

ACCESSIBLE

'-1

URINAL

SCREEN

(URS)

TOILET

PARTITION

(PART)

FLOOR LINE

MAX

6"

MAX

1' - 0"

T

O

GRAB BAR,

REQD (GB3)

GRAB BAR,

REQD (GB1)

GRAB

BAR,

REQD

(GB2)

(2) TOILET PAPER

DISPENSER DBL

ROLL (TPD)

SANITARY NAPKIN

DISPOSAL (SND)

WALL

MOUNT

TOILET

41"

39" TO

MIN

3' - 6"

1' - 6" 7" 8"

MIN

3' - 0"

A D

A R

E Q

M A

X

SOAP

DISPENSER

(SD)

LAVATORY

MIRROR

(MIR)

C L R

M A

X

M A

X

ELECTRIC

WATER

COOLER

HI-LO

(EWC)

M

IN

SHOWER

CURTAIN

ROD

(SCR)

ROBE

HOOKS

(RH)

PAPER

TOWEL

DISP.

(PTD)

SANITARY

NAPKIN

DISPOSAL

(SND)

"FAUCET ON

OPPOSITE WALL

FROM MOP

STRIP

(IF APPLICABLE)

SHELF W/

MOP STRIP

(MS)

MOP BASIN

FIRE

EXTINGUISHER

CABINET

(FEC)

M A

X

FOLDING

SHOWER

SEAT

(FSS)

MAX

2' - 3"

1' - 4" SHOWER HEIGHT

ACCESSORIES

M A

X

T.O. HOSE MOUNTING

BRACKET

DESIGN OPTION, STD HEAD

FLEXIBLE SHOWER SPRAY HOSE - 60" L

SINGLE LEVEL MIXING VALVE CONTROL

GRAB BAR (GB4)

MEN'S

MIR1 MIR1 MIR1

PTD

SD SD PTD8

A-402

4.203

MEN'S

URS URS

PART

TPDTPD

GB2

GB1

GB3

TPD TPD

4.203

GB1

GB3

MEN'S

LOCKER

4.106

4.106

4.106

VSC

SCR

FSS

RH

SCR SCR

VSC

FSS

RH

VSC

FSS

RH

VSC

FSS

RH

SA6

4.203

SCR

WOMEN'S

MIR1

EHD

SD

MIR1

SDPTD 8

A-402

4.203

WOMEN'S

TPD

GB2

GB1

GB3

SND

TPD

SND

TPD

SND

PART

4.203

WOMEN'S

LOCKER

VSC

SCR

FSS

RH

VSC

FSS

RH

SCR

4.106

SCR

VSC

FSS

RH

4.203

CTB-1

CT-1

CT-1

CT-2

CT-2

SEE SHEET A-602 FOR TILE FINISH INFORMATION

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

ISSUED

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

/2

/2

:3 :1

P

M C

R e v it L o c a l\

-1

.0

-A

-C e n tr a l-m a rk .b ra it h w a it e .r v t

A-401

ENLARGED

INTERIOR PLANS

M

IC

H

IG

A N

A

IR

N A

T

IO

N A

L G

U A

R D

B A

T T

L E

C R

E E

K A

N G

B B

A T

T L E

C R

E E

K M

IC

H

IG

A

N

B A

T T

L E

C R

E E

K A

N G

B R

E P

A

IR

B L D

G

F O

R C

Y B

E R

O P

E R

A T

IO

N

S S

Q U

A D

R O

N

3141900-160242.01

MAB

RCL

DECEMBER 14, 2017

JTP

1/4" = 1'-0"1

ENLARGED FLOOR PLAN

1/4" = 1'-0"8

ACCESSORY MOUNTING HEIGHTS

1/4" = 1'-0"2

INTERIOR ELEVATION

1/4" = 1'-0"3

INTERIOR ELEVATION

1/4" = 1'-0"4

INTERIOR ELEVATION

1/4" = 1'-0"5

INTERIOR ELEVATION

1/4" = 1'-0"6

INTERIOR ELEVATION

1/4" = 1'-0"7

INTERIOR ELEVATION

KEYED NOTES

4.106 12" X 48" HDPE BENCH WITH STAINLESS STEEL TRAPEZOID PEDESTALS,

COLOR TO BE SELECTED BY GOVERNMENT REPRESENTATIVE.

4.108 REFRIGERATOR GFCI.

4.110 COFFEE MAKER GFCI.

4.127 ALIGN GYPSUM BOARD OF NEW PARTITION WITH EXISTING GYPSUM BOARD.

4.128 INSTALL EXISTING ENOOK CABINET.

4.129 RECESSED PLASTIC LAMINATE ELECTRONIC DEVICE STORAGE CABINET.

4.136 DOUBLE TIER HDPE LOCKERS.

4.137 SINGLE TIER HDPE LOCKERS.

4.203 SEE DETAIL 9/A-401 FOR TYPICAL WALL TILE ELEVATION.

1/2" = 1'-0"9

TOILET, SHOWER AND LOCKER ROOM

TYPICAL WALL TILE ELEVATION

12/14/17 B3 FINAL

1 07/27/18 ADDENDUM 01

Sheets
A-401 - ENLARGED INTERIOR PLANS

File details come from the government source that posted it.