171214_-_FULL_SET.pdf
PDF 20 MB Posted
- Attached to
- Alter/Reconfigure B6922 for Cyber Ops Federal contract opportunity
- Solicitation number
- W912JB-18-R-8004
- Issued by
- Department of the Army National Guard
About this file
DRAWINGS - FULL SET
View the file
Other files for this federal contract opportunity
Show all 27
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LOT
A
LOT
P
LOT
C
L O T
D
LOT
E
LOT
E
LOT
E
LO
T
H
LO
T
I
EAST APRON
TRANSIENT PAD
LOT
F
LOT
J
LOT
O
F
TAXILANE - F
LOT
S
LOT
B
DEMO 10 JUNE
RE
MO
VE
D
.1
REMOVED
MAIN GATE
SIGN
SIGN
SIGN
CONTRACTOR GATE
RE
C R
UI T
IN
G
VIS
I T O
RS
ON
LY
RE
C R
UI T
IN
G
VIS
I T O
RS
ON
LY
RE
C R
UI T
IN
G
VIS
I T O
RS
ON
LY
RESERVED
VISITOR
RESERVED
VISITOR
RESERVED
VISITOR
R E S E R V
ED
R E S E R V
ED
R E S E R V
ED
H A N D
IC
A P
H A N D
IC
A P
R E S E R V
ED
R E S E R V
ED
R E S E R V
ED
HAND ICAP
CUSTO MER
HAND ICAP
CUSTO MER
CUSTO MER
RESERVED
RESERVED
RESERVED
R E S E R V
ED
R E S E R V
ED
R E S E R V
ED
R E S E R V
ED
H A N D
IC
A P
H A N D
IC
A P
LOT
G
LOT
N
U T A
U T A
U T A
RESERVEDUTA
RESERVED
RESERVEDUTA
RESERVEDUTA
RESERVED
RESERVED
U T A
2 3
U T A
U T A
U T A
RESERVED
RESERVED
RESERVED
RESERVED
RESERVEDUTA
RESERVEDUTA
RESERVEDUTA
RESERVEDUTA
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
R E S E R V
ED
0 R E S E R V
ED
R E S E R V
ED
9 R E S E R V
ED
R E S E R V
ED
RESERVED
RESERVED
RESERVED
RE
SE
RV
ED
RE
SE
RV
ED
RE
SE
RV
ED
RE
SE
RV
ED
UT
A
RE
SE
RV
ED
RE
SE
RV
ED
UT
A55
RE
SE
RV
ED
UT
A56
RE
SE
RV
ED
UT
A57
RE
SE
RV
ED
RE
SE
RV
ED
RE
SE
RV
ED
74RE
SE
RV
ED
RESERVEDUTA
RESERVEDUTA
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
GO
RESERVED
RESERVED
RESERVEDUTA
RESERVED
RESERVEDUTA
R E S E R V
ED
U T A
7 R E S E R V
ED
U T A
R E S E R V
ED
U T A
R E S E R V
ED
R E S E R V
ED
U T A
R E S E R V
ED
R E S E R V
ED
NEW SIDEWALK
08'
NEW SIDEWALK
08'
ABI#1
NEW
SIDEWALK
ABI
#1
N E W
S
ID
E W
AL
K
A B I
N E W
S
ID
E W
AL
K
A B I
NEW
SIDEWALK
ABI
#1
THUNDERBOLT
AVE.
THUNDERBOLT
AVE.
S A B R E
S T R E E T
S P
IT
F
IR
E
A V E
MUSTANG
AVE.
MUSTANG
AVE.
FALCON
STREET
D R A G O N F L Y
TALON
DRIVE
MUSTANG
AVE.
DICKMAN
AVE.
S E N
TR
Y
D R
IV
E
P H A N
TO
M
A V E
S C O R P
IO
N
S T R E E T
THUNDERB
OLT
AVE.
TH
U N
DE
RB
O
LT
AV
E.
C A N B
ER
R A
PROJECT LOCATION
BUILDING 6922
NORTH
VICINITY MAP
MICHIGAN
LANSING
CALHOUN
COUNTY
NORTH
BATTLE CREEK
SPRINGFIELD
LOCAL VICINITY MAP
BATTLE
CREEK ANGB
WK KELLOGG
AIRPORT
NORTH
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
ANG No.:
/1 /2
:0
:5
P M
C R e v it L o c a l\
-1
.0
-A
-C e n tr a l-m a b
.r v t
B A
T T
L E
C R
E E
K A
N G
B B
A T
T L E
C R
E E
K M
IC
H
IG
A
N
G-001
COVER SHEET
M
IC
H
IG
A N
A
IR
N A
T
IO
N A
L G
U A
R D
B A
T T
L E
C R
E E
K A
N G
B R
E P
A
IR
B L D
G
F O
R C
Y B
E R
O P
E R
A T
IO
N
S S
Q U
A D
R O
N
BATTLE CREEK ANGB, REPAIR BLDG 6922
FOR CYBER OPERATIONS SQUADRON
BATTLE CREEK ANGB
BATTLE CREEK, MICHIGAN
MBMV162472
MICHIGAN AIR NATIONAL GUARD
3141900-160242.01
MAB
RCL
DECEMBER 14, 2017
JTP
ELECTRICAL
E-001 NOTES, SYMBOLS & ABBREVIATIONS
ED-101 FIRST FLOOR DEMOLITION PLAN - LIGHTING
ED-131 FIRST FLOOR DEMOLTION PLAN - POWER
ED-132 ROOF DEMOLITION PLAN - POWER
ED-701 ONE-LINE DIAGRAM DEMOLITION
E-101 FIRST FLOOR PLAN - LIGHTING
E-131 FIRST FLOOR PLAN - POWER
E-132 ROOF PLAN - POWER
E-401 ENLARGED PLANS
E-402 ENLARGED PLANS
E-501 DETAILS
E-502 DETAILS
E-601 SCHEDULES
E-602 SCHEDULES
E-603 SCHEDULES
E-604 SCHEDULES
E-605 SCHEDULES
E-606 SCHEDULES
E-607 SCHEDULES
E-701 ONE-LINE DIAGRAM
TECHNOLOGY SYSTEMS
T-001 NOTES, SYMBOLS & ABBREVIATIONS
T-002 NOTES, SYMBOLS & ABBREVIATIONS
TD101 FIRST FLOOR - COMMUNICATIONS - DEMOLITION
TD121 FIRST FLOOR - SECURITY - DEMOLITION
TD141 FIRST FLOOR - AUDIO/VISUAL - DEMOLITION
TD401 ENLARGED DEMOLITION PLANS
T-101 FIRST FLOOR PLAN - COMMUNICATIONS
T-102 FIRST FLOOR PLAN - PATHWAYS
T-121 FIRST FLOOR PLAN - SECURITY
T-141 FIRST FLOOR PLAN - AUDIO/VISUAL
T-401 ENLARGED PLANS
T-402 ENLARGED PLANS
T-403 ENLARGED PLANS
T-501 DETAILS
T-502 DETAILS
T-503 DETAILS
T-601 SCHEDULES
T-701 ONE-LINE DIAGRAMS
FIRE PROTECTION
F-001 FIRE PROTECTION SYMBOLS, ABBREVIATIONS, NOTES AND DETAILS
FD101 FIRE PROTECTION DEMOLITION PLUMBING PLAN
FD-141 FIRST FLOOR PLAN - FIRE ALARM - DEMOLITION
F-101 FIRE PROTECTION - FIRST FLOOR PLAN
F-141 FIRST FLOOR PLAN - FIRE ALARM
F-541 FIRE ALARM DETAILS
PLUMBING
P-001 PLUMBING NOTES & SYMBOLS
PD100 UNDERGROUND DRAIN AND VENT DEMOLITION PLUMBING PLAN
PD101 ABOVEGROUND DRAIN AND VENT DEMOLITION PLUMBING PLAN
PD131 SUPPLY DEMOLITION PLUMBING PLAN
P-100 UNDERGROUND DRAIN AND VENT PLUMBING PLAN
P-101 FIRST FLOOR DRAIN AND VENT PLUMBING PLAN
P-131 FIRST FLOOR SUPPLY PLUMBING PLAN
P-401 ENLARGED PLUMBING PLANS
P-501 PLUMBING DETAILS
P-601 PLUMBING SCHEDULES
P-901 DRAIN AND VENT RISER DIAGRAM
P-902 SUPPLY PLUMBING RISER DIAGRAM
MECHANICAL
M-001 MECHANICAL NOTES & SYMBOLS
MD101 FIRST FLOOR HVAC DEMO PLAN
MD102 ROOF HVAC DEMO PLAN
MD131 FIRST FLOOR MECHANICAL PIPING DEMO PLAN
M-101 FIRST FLOOR HVAC PLAN
M-102 ROOF HVAC PLAN
M-131 FIRST FLOOR MECHANICAL PIPING PLAN
M-401 MECHANICAL - ENLARGED PLANS
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-511 MECHANICAL DETAILS
M-601 MECHANICAL SCHEDULES
M-602 MECHANICAL SCHEDULES
M-603 MECHANICAL SCHEDULES
M-611 MECHANICAL SCHEDULES
M-612 MECHANICAL SCHEDULES
M-613 MECHANICAL SCHEDULES
M-701 CONTROL SCHEMATICS
M-702 CONTROL SCHEMATICS
GENERAL
G-001 COVER SHEET
G-002 CYBER OPERATIONS ENCLOSURE
G-003 CONTRACTOR LAY DOWN AND PARKING AREA
G-004 CONSTRUCTION OPERATIONS AND PHASING NOTES
G-102 CODE ANALYSIS SCHEDULE
G-103 LIFE SAFETY PLAN
CIVIL
C-021 EXISTING SITE PLAN
C-041 SITE REMOVALS PLAN
C-042 SITE REMOVALS PLAN
C-101 SITE IMPROVEMENTS PLAN
C-102 SITE IMPROVEMENTS PLAN
C-501 SITE DETAILS
C-601 FENCE DETAILS
STRUCTURAL
S-001 STRUCTURAL NOTES
S-002 STRUCTURAL NOTES
SD111 FLATWORK DEMOLITION PLAN
SD121 WALL DEMOLITION PLAN
S-101 FOUNDATION PLAN
S-111 FLATWORK PLAN
S-121 STRUCTURAL WALL PLAN
S-151 STRUCTURAL ROOF FRAMING PLAN
S-501 FOUNDATION DETAILS
S-521 STRUCTURAL WALL DETAILS
S-541 FRAMING DETAILS
ARCHITECTURAL
A-001 NOTES & SYMBOLS
AD101 FIRST FLOOR DEMOLITION PLAN
AD102 ROOF DEMOLITION PLAN
A-101 FIRST FLOOR PLAN
A-102 ROOF PLAN
A-121 FIRST FLOOR CEILING PLAN
A-141 PARTITION TYPES
A-201 EXTERIOR ELEVATIONS
A-202 EXTERIOR ELEVATIONS
A-301 BUILDING SECTIONS
A-302 BUILDING SECTIONS
A-401 ENLARGED INTERIOR PLANS
A-402 ENLARGED INTERIOR ELEVATIONS
A-501 EXTERIOR PLAN DETAILS
A-601 ARCHITECTURAL SCHEDULES
A-602 ARCHITECTURAL SCHEDULES
A-701 FINISH PLAN
A-702 ENLARGED FINISH PLAN
A-801 SIGNAGE
A-901 FIRST FLOOR FURNITURE PLAN
SHEET INDEX
12/14/17 B3 FINAL
R E
F
REF.REF.
UP
WEAPONS
/ INTEL
ENTRY
LOBBY
PASSAGE
PASSAGE
SSO
MAN TRAPPASSAGE
ASC/IDS
FLT A
FLT B
TEAMS
PASSAGE
TRAINING
CONFERENCE
COF
COS
ELECTRICAL
COS
MECHANICAL
SERVER
CYBER MAINTENCE /
OPEN STORAGE COS
COMM.
ACOS
AFFOR
ACOS
COMM.
CONFERENCE
ROOM
PASSAGE
OFFICE
A2/A6
A3/A5
A4/A7
A1
FIRST
SGT
DIRECTOR
OF OPS
SUPER
COS
COMMANDER
ACOS
COMMANDER
OPEN
OFFICE
112 ACOS
ELECTRICAL
ACOS
MECHANICAL
G.O.
OFFICE
ACOS /
EXEC
CONFERENCE
ROOM
STORAGE
112B
BREAK
ROOM
WOMEN'S
LOCKER
MEN'S
LOCKER
MEN'S
WOMEN'S
JANITOR
MEN'S
VESTIBULE
OPEN OFFICE
STORAGE
FIRE
CLOSET
G-002
765432
11'2'3'4'
A
B
AA
A.7
C
D
FIRST FLOOR
100' - 0"
TOW LOW WALL
116' - 8"
TOW HIGH WALL
128' - 8"
TOW 2012 ADD
120' - 0"
FLT A
TEAMS
CONFERENCE
COF
142 143
CYBER MAINTENCE /
OPEN STORAGE
AB
AAA.7CD
ENCLOSURE PLAN LEGEND:
CYBER OPERATIOS ENCLOSURE AREA
SOUND ASSEMBLY GROUP 3 - MIN STC 45
SOUND ASSEMBLY GROUP 4 - MIN STC 50
ENCLOSURE PLAN GENERAL NOTES:
1. SEE SHEET A-141 FOR PARTITION TYPES AND STC RATINGS AND TYPICAL
SOUND PARTITION HEAD CONDITION.
REFERENCED DOCUMENTS: UFC 4-010-05, ICD/ICS705
WALL WILL BE FROM FLOOR SLAB (TRUE FLOOR) TO UNDERSIDE OF FLOOR OR
ROOF DECK (TRUE CEILING). PERIMETER WALLS, FLOOR AND CEILING SHALL BE
PERMANENTLY AND SOLIDLY CONSTRUCTED AND ATTACHED TO EACH OTHER.
SEAL PARTITIONS CONTINUOUSLY WITH ACOUSTICAL FOAM OF SEALANT (BOTH
SIDES) AND FINISHED TO MATCH WALL WHENEVER IT ABUTS ANOTHER ELEMENT
SUCH FLOOR, CEILING, WALL, COLUMN OR MULLION. WALLS WILL BE UNIFORMLY
FINISHED ON BOTH SIDES FROM FLOOR SLAB (TRUE FLOOR) TO UNDERSIDE OF
FLOOR OR ROOF DECK (TRUE CEILING).
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
/1 /2
:0
:0
P M
C R e v it L o c a l\
-1
.0
-A
-C e n tr a l-m a b
.r v t
G-002
CYBER OPERATIONS
ENCLOSURE
M
IC
H
IG
A N
A
IR
N A
T
IO
N A
L G
U A
R D
B A
T T
L E
C R
E E
K A
N G
B B
A T
T L E
C R
E E
K M
IC
H
IG
A
N
B A
T T
L E
C R
E E
K A
N G
B R
E P
A
IR
B L D
G
F O
R C
Y B
E R
O P
E R
A T
IO
N
S S
Q U
A D
R O
N
3141900-160242.01
MAB
RCL
DECEMBER 14, 2017
JTP
3/32" = 1'-0"1
CYBER OPERATIONS ENCLOSURE PLAN
3/32" = 1'-0"2
CROSS SECTION CYBER OPERATIONS ENCLOSURE
NEW SIDEWALK
08'
PROJECT BUILDING
CONTRACTOR GATEMAIN GATE
DICKMAN AVE.
THUNDERBOLT AVE.
S A
B R
E S
T R
E E
T
P H
A N
T O
M A
V E
MUSTANG AVE.
TH
U
N D
ER
BO
LT
A
VE.
TH
U N D
ER
BO
LT AVE.
S C
O R
P
IO
N S
T R
E E
T
D R
A G
O N
F L Y
FALCON STREET
HAUL ROUTE
HAUL ROUTE
HAUL RO
UTE
CONTRACTOR'S
PARKING LOT
CONTRACTOR'S
TRAILER
LAY DOWN AREA
CONSTRUCTION FENCE:
TEMPORARY, 7' TALL, CHAIN LINK.
GENERAL NOTES:
1. COORDINATE FINAL LOCATIONS WITH CONTRACTION OFFICER'S REPRESENTATIVE.
2. ORIENTATION OF NORTH ON GENERAL AND CIVIL DRAWINGS SHEETS DIFFERS FROM PLAN SHEETS.
3. ALL CONSTRUCTION WORKERS WILL BE REQUIRED TO ADHERE TO THE SITE SECURITY PLAN.
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
/1 /2
:0
:0
P M
C R e v it L o c a l\
-1
.0
-A
-C e n tr a l-m a b
.r v t
G-003
CONTRACTOR LAY
DOWN AND PARKING
AREA
M
IC
H
IG
A N
A
IR
N A
T
IO
N A
L G
U A
R D
B A
T T
L E
C R
E E
K A
N G
B B
A T
T L E
C R
E E
K M
IC
H
IG
A
N
B A
T T
L E
C R
E E
K A
N G
B R
E P
A
IR
B L D
G
F O
R C
Y B
E R
O P
E R
A T
IO
N
S S
Q U
A D
R O
N
3141900-160242.01
MAB
RCL
DECEMBER 14, 2017
JTP
1" = 80'-0"1
CONTRACTOR LAY DOWN AND PARKING
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
/1 /2
:0
:0
P M
C R e v it L o c a l\
-1
.0
-A
-C e n tr a l-m a b
.r v t
G-004
CONSTRUCTION
OPERATIONS AND
PHASING NOTES
M
IC
H
IG
A N
A
IR
N A
T
IO
N A
L G
U A
R D
B A
T T
L E
C R
E E
K A
N G
B B
A T
T L E
C R
E E
K M
IC
H
IG
A
N
B A
T T
L E
C R
E E
K A
N G
B R
E P
A
IR
B L D
G
F O
R C
Y B
E R
O P
E R
A T
IO
N
S S
Q U
A D
R O
N
3141900-160242.01
MAB
RCL
DECEMBER 14, 2017
JTP
12/14/17 B3 FINAL
THE FOLLOWING NOTES ARE IN ACCORDANCE WITH THE MOST CURRENT EDITION OF FAA AC 150/5370-2, OPERATIONAL SAFETY ON AIRPORTS DURING CONSTRUCTION, ALONG WITH THOSE INCLUDED IN THE PROJECT SPECIFICATIONS.
SAFETY PLAN COMPLIANCE DOCUMENT
A. THE CONTRACTOR SHALL PREPARE A SAFETY PLAN COMPLIANCE DOCUMENT (SPCD) DESCRIBING HOW THE REQUIREMENTS OF THE CONSTRUCTION SAFETY AND PHASING PLAN WILL BE MET. THE SPCD SHALL INCLUDE A CERTIFICATION STATEMENT BY
THE CONTRACTOR THAT:
1. INDICATES FULL UNDERSTANDING OF THE OPERATIONAL SAFETY REQUIREMENTS OF THE CONSTRUCTION SAFETY AND
PHASING PLAN AND;
2.ASSERTS NO DEVIATIONS SHALL BE MADE FROM THE APPROVED SAFETY PHASING PLAN AND SPCD UNLESS WRITTEN APPROVAL IS GRANTED BY THE AIRPORT. THE SPCD SHALL FOLLOW THE FORMAT OF THE MOST CURRENT EDITION OF FAA AC 150/5370-2, SECTION 204(b) AND SHALL ADDRESS ITEMS (1)-(18) PER THE REQUIREMENTS OF THE AC.
B. THE CONTRACTOR SHALL SUBMIT THE SPCD TO THE BUREAU OF AERONAUTICS FOR DELIVERY TO THE AIRPORT FOR REVIEW AND APPROVAL A MIN. OF FOURTEEN (14) DAYS PRIOR TO THE ANTICIPATED ISSUE OF THE NOTICE TO PROCEED. COPIES OF THE APPROVED CONSTRUCTION SAFETY PHASING PLAN AND SAFETY PLAN COMPLIANCE DOCUMENT SHALL BE MAINTAINED AT
THE PROJECT SITE.
RESTRICTED AREAS / SAFETY AREAS
A. CONSTRUCTION ACTIVITY ADJACENT TO ACTIVE RUNWAYS, TAXIWAYS, AND APRONS SHALL BE COORDINATED WITH THE
AIRPORT AND MAY BE AUTHORIZED AFTER :
1.NOTICES TO AIRMEN (NOTAM'S) HAVE BEEN ISSUED BY THE AIRPORT,
2.BARRICADES AND LIGHTING PROVISIONS HAVE BEEN IMPLEMENTED BY THE CONTRACTOR, AND
3. IT HAS BEEN DETERMINED THAT THE HEIGHT OF EQUIPMENT AND MATERIALS IS BEYOND THE REACH, OR SAFELY BELOW, AIRCRAFT USING ADJACENT OPERATIONAL AREAS. THE AIRPORT WILL SUPPLY INFORMATION FOR RUNWAY APPROACHES
AND OTHER AREAS IF REQUIRED.
B. NO CONSTRUCTION MAY OCCUR WITHIN AN EXISTING RUNWAY SAFETY AREA (WITHIN 250 FEET OF AN ACTIVE RUNWAY CENTERLINE AND 1,000 FEET BEYOND THE RUNWAY THRESHOLDS) OR TAXIWAY SAFETY AREA (WITHIN 85.5 FEET OF AN ACTIVE TAXIWAY CENTERLINE OR 48 FEET FROM THE EDGE OF AN APRON) WHILE THE RUNWAY/TAXIWAY IS OPEN TO AIRCRAFT OPERATIONS. OPEN TRENCHES OR EXCAVATIONS ARE NOT PERMITTED WITHIN THE SAFETY AREA OF AN OPEN RUNWAY OR TAXIWAY. IF THE RUNWAY/TAXIWAY MUST BE OPENED BEFORE EXCAVATIONS ARE BACKFILLED, THE EXCAVATIONS MUST BE COVERED IN SUCH A WAY AS TO ALLOW THE HEAVIEST AIRCRAFT OPERATING ON THE RUNWAY/TAXIWAY TO CROSS THE COVERING WITHOUT DAMAGE TO THE AIRCRAFT. THE SAFETY AREA MUST BE GRADED WITH NO POTENTIALLY HAZARDOUS RUTS, HUMPS, DEPRESSIONS, OR OTHER SURFACE VARIATIONS UPON OPENING. EXCAVATIONS WITHIN THE CONSTRUCTION
AREA(S) MUST BE PROMINENTLY MARKED.
C. CONSTRUCTION MAY BE PERMITTED IN THE RUNWAY OBJECT FREE AREA (WITHIN 400 FEET OF AN ACTIVE RUNWAY CENTERLINE AND 1,000 FEET BEYOND THE RUNWAY THRESHOLDS), BUT EQUIPMENT MUST BE REMOVED FROM THE ROFA WHEN NOT IN USE AND MATERIAL SHOULD NOT BE STOCKPILED WITHIN THE ROFA. UNLIKE THE RUNWAY, NO CONSTRUCTION MAY TAKE PLACE WITHIN THE OBJECT FREE AREA OF AN OPEN TAXIWAY (WITHIN 129.5 FEET OF AN ACTIVE TAXIWAY
CENTERLINE OR 92 FEET FROM THE EDGE OF AN APRON), UNLESS
1.THE TOFA DIMENSION IS TEMPORARILY ADJUSTED FOR USE BY SMALLER AIRCRAFT ONLY;
2.TEMPORARY OFFSET TAXIWAY MARKINGS ARE USED; OR
3.CONSTRUCTION PROCEEDS WITH THE FOLLOWING RESTRICTIONS: APPROPRIATE NOTICES TO AIRMEN (NOTAM'S) HAVE
BEEN ISSUED BY THE AIRPORT, BARRICADES AND LIGHTING PROVISIONS HAVE BEEN IMPLEMENTED BY THE CONTRACTOR, AND FLAGGERS AND WINGWALKERS ARE UTILIZED TO MAINTAIN A 5 FOOT SEPARATION BETWEEN AIRCRAFT AND ALL
EQUIPMENT OR MATERIALS.
D. STOCKPILED MATERIALS AND EQUIPMENT STORAGE IS NOT PERMITTED WITHIN THE SAFETY AREA OR OBJECT FREE AREA OF AN OPERATIONAL RUNWAY OR TAXIWAY. IF THE CONTRACTOR WISHES TO STOCKPILE MATERIALS OR EQUIPMENT ADJACENT TO A RUNWAY/TAXIWAY OBJECT FREE AREA, HE MUST FIRST COORDINATE WITH THE AIRPORT OPERATOR TO ENSURE THAT
1.APPROPRIATE LIGHTING AND BARRICADES ARE IN PLACE, AND
2.THE STOCKPILED MATERIALS DO NOT CREATE A WILDLIFE ATTRACTANT OR FOREIGN OBJECT DEBRIS (FOD) HAZARD.
EXCAVATION AND RESULTANT STOCKPILES ADJACENT TO OTHER PAVED SURFACES MUST BE APPROPRIATELY MARKED WITH BARRICADES, AS DIRECTED BY THE AIRPORT. DEBRIS SHALL NOT BE DEPOSITED ON ANY PORTION OF AN OPERATIONAL RUNWAY, TAXIWAY OR APRON. SHOULD ANY DEBRIS BE DEPOSITED ON ACTIVE OPERATIONAL AREAS, EITHER INTENTIONALLY OR ACCIDENTALLY, IT SHALL BE REMOVED IMMEDIATELY TO THE SATISFACTION OF THE BCE AND
THE AIRPORT.
E. PERSONNEL, MATERIAL, AND/OR EQUIPMENT SHALL NOT PENETRATE THE RUNWAY OBSTACLE FREE ZONE (OFZ) OR THRESHOLD SIGHTING SURFACES WHILE THE RUNWAY IS OPEN. RUNWAY APPROACH/DEPARTURE AREAS AND CLEARWAYS
SHALL BE PROTECTED.
F. CLOSING OF RUNWAYS OR TAXIWAYS:
WHEN IT BECOMES NECESSARY TO CLOSE OR CHANGE THE STANDARD OPERATIONS OF A RUNWAY OR TAXIWAY, THE CONTRACTOR SHALL, THROUGH THE BCE, NOTIFY THE AIRPORT 72 BUSINESS HOURS IN ADVANCE OF THE PROPOSED CHANGE IN OPERATIONS. SHOULD A RUNWAY BE TEMPORARILY CLOSED, THE CONTRACTOR SHALL MARK THE AFFECTED RUNWAY WITH CLOSURE CROSSES IN ACCORDANCE WITH THE CLOSURE CROSS SPECIFICATIONS FOUND IN THE MOST CURRENT EDITION OF FAA AC 150/5345-55. CLOSURE CROSSES SHALL REMAIN IN PLACE UNTIL NORMAL RUNWAY OPERATIONS RESUME, AND BE
REMOVED/REINSTALLED DAILY IF NECESSARY.
G. OPEN-FLAME WELDING OR TORCH CUTTING OPERATIONS ARE PROHIBITED UNLESS ADEQUATE FIRE AND SAFETY PRECAUTIONS ARE PROVIDED AS APPROVED BY THE AIRPORT. USE OF ELECTRICAL BLASTING CAPS IS PROHIBITED ON OR WITHIN 1,000 FEET OF THE AIRPORT PROPERTY. FLARE POTS ARE PROHIBITED WITHIN THE AIR OPERATIONS AREA (AOA).
H. ALL VEHICLES ARE TO BE PARKED AND SERVICED IN THE CONTRACTOR STAGING/STORAGE AREA.
I. THE CONTRACTORS' EQUIPMENT IS STRICTLY LIMITED TO THE CONSTRUCTION AREAS DURING CONSTRUCTION AND TO THE CONTRACTOR STAGING/STORAGE AREA DURING NON-CONSTRUCTION PERIODS, EXCEPT AS PROVIDED ON THE PLANS, IN THE
CONTRACT SPECIAL PROVISIONS, OR AS MAY BE AUTHORIZED BY THE AIRPORT IN WRITING.
J. DURING NON-WORKING HOURS BY THE CONTRACTOR, ALL WORK AREAS WITHIN THE SAFETY AREA OF ANY ACTIVE RUNWAY OR TAXIWAY, THE CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING GRADES NO STEEPER THAN A 10:1 SLOPE. EVENLY GRADED TRANSITIONS OFF ALL EXISTING PAVEMENT EDGES, USING BASE COURSE MATERIAL AT SAME GRADE AS REMAINING PAVEMENT WILL BE REQUIRED. AT NO LOCATION WILL A GRADE CHANGE BE GREATER THAN 2 INCHES.
MARKING, LIGHTING, AND BARRICADES
NO CONSTRUCTION SHALL BEGIN UNTIL ALL BARRICADES, CLOSURE CROSSES, AND SAFETY MEASURES HAVE BEEN PLACED AS
SHOWN ON THE PREVIOUS SHEET AND APPROVED BY THE AIRPORT OPERATIONS PERSONNEL.
A. CONSTRUCTION EQUIPMENT:
ALL CONSTRUCTION EQUIPMENT MUST BE MARKED WITH A 3 FEET BY 3 FEET ORANGE AND WHITE CHECKERED FLAG AND/OR AMBER BEACON. FOR NIGHT CONSTRUCTION, ALL EQUIPMENT MUST BE EQUIPPED WITH AN AMBER BEACON. ALL CONSTRUCTION VEHICLES MUST BE CLEARLY MARKED WITH THE COMPANY NAME/LOGO AT ALL TIMES IN ACCORDANCE WITH
THE MOST CURRENT EDITION OF FAA AC 150/5210-5.
B. EXCAVATION/STOCKPILES:
STOCKPILED MATERIALS AND EQUIPMENT STORAGE IS NOT PERMITTED WITHIN THE SAFETY AREA, OBJECT FREE AREA, AND/OR OBSTACLE FREE ZONE OF AN OPERATIONAL RUNWAY. IF THE CONTRACTOR WISHES TO STOCKPILE MATERIALS OR EQUIPMENT ADJACENT TO RUNWAY SAFETY AREAS OR RUNWAY OBSTACLE FREE ZONES, HE/SHE MUST FIRST COORDINATE WITH THE AIRPORT OPERATOR TO ENSURE THAT APPROPRIATE LIGHTING AND BARRICADES ARE IN PLACE AND TO ENSURE THAT THE STOCKPILED MATERIALS DO NOT CREATE A WILDLIFE ATTRACTANT OR FOREIGN OBJECT DEBRIS (FOD) HAZARD.
EXCAVATION AND RESULTANT STOCKPILES ADJACENT TO OTHER PAVED SURFACES MUST BE APPROPRIATELY MARKED WITH
BARRICADES, AS DIRECTED BY THE BCE.
C. IF ANY AIRCRAFT MOVEMENT AREA MUST BE CLOSED, THE CONTRACTOR SHALL FURNISH AND PLACE PORTABLE BARRICADES ACROSS RUNWAYS, APRONS, OR TAXIWAYS TO KEEP VEHICLES FROM ENTERING ACTIVE OPERATION AREAS AND TO KEEP AIRCRAFT FROM TAXIING INTO CONSTRUCTION AREAS. SUPPLEMENT BARRICADES WITH SIGNS AS NECESSARY.
D. BARRICADES SHALL BE MARKED WITH DIAGONAL, ALTERNATING ORANGE AND WHITE STRIPES AND SUPPLEMENTED WITH EITHER FLASHING OR STEADY-BURNING LIGHTS DURING HOURS OF RESTRICTED VISIBILITY OR DARKNESS. LIGHTS SHALL BE THE BARRICADE TYPE TYPICAL FOR CONSTRUCTION ZONES, AND RED IN COLOR. ALL LIGHTS MUST BE CHECKED NIGHTLY TO
ENSURE THAT THEY ARE OPERATING. ANY LIGHTS NOT FUNCTIONING SHALL BE REPLACED.
THE INTENSITY OF THE LIGHTS AND BARRICADE LAYOUT MUST ADEQUATELY AND WITHOUT AMBIGUITY DELINEATE THE HAZARDOUS AREA. BARRICADES SHALL BE CAPABLE OF INTERLOCKING TO MAKE A PHYSICAL BORDER AROUND
CONSTRUCTION SITE.
BARRICADES SHALL BE LOW LEVEL AVIATION BARRICADES SPECIFICALLY MANUFACTURED AND DESIGNED FOR SUCH PURPOSE. THEY SHALL BE ALTERNATING ORANGE AND WHITE IN COLOR 10 INCHES HIGH AND 96 INCHES LONG, MADE OF UV-RESISTANT POLYETHYLENE AS MANUFACTURED BY MULTI-BARRIER (MODEL AR 10x96 HDPE) OR APPROVED EQUAL.
E. TRAFFIC CONTROL DEVICES:
ALL TRAFFIC CONTROL DEVICES SHALL MEET INDUSTRY AND WISCONSIN DOT STANDARDS ACCESS ROUTES USED BY CONTRACTOR MUST BE CLEARLY MARKED TO PREVENT INADVERTENT ENTRY TO AREAS OPEN TO AIRPORT OPERATIONS.
CONTRACTOR SHALL PROVIDE "25 MPH SPEED LIMIT" SIGNS AND "HAUL ROUTE" SIGNS WHEN HAULING ON THE AIRPORT ROADWAYS AND TAXIWAYS. OTHER SPEED LIMITS THAT MUST BE OBSERVED ARE, 10 MPH ON ANY AIRCRAFT APRON AND
5 MPH WITHIN 50 FEET OF ANY AIRCRAFT.
F. CONTRACTOR MUST PROVIDE AN EMERGENCY CONTACT AVAILABLE 24 HOURS FOR MAINTENANCE OF CONSTRUCTION LIGHTING AND BARRICADING, OR ANY OTHER ISSUES THAT INTERFERE WITH THE OPERATIONS AT THE AIRPORT.
G. CONTRACTOR SHALL, ON A DAILY BASIS, COORDINATE WITH THE AIRPORT MAINTENANCE SUPERINTENDENT TO ENSURE ALL REQUIRED AIRFIELD LIGHTING IS FUNCTIONAL, LIGHTED BARRICADES ARE OPERATIONAL, AND TO REVIEW NOTAM'S.
FUEL SUPPORT
ANY TYPE OF FUELING SUPPORT FACILITY OR DEVICE USED TO REFUEL CONSTRUCTION EQUIPMENT IS SUBJECT TO LOCAL FIRE INSPECTION. LOCAL FIRE CODES AND SAFETY STANDARDS SHALL BE MET PRIOR TO COMMENCEMENT OF WORK.
SWEEPING / CLEAN-UP
A. THE CONTRACTOR SHALL HAVE SWEEPING OR VACUUMING CAPABILITIES ON-SITE AT ALL TIMES IN ORDER TO REMOVE DEBRIS FROM ACTIVE OPERATIONAL AREAS (RUNWAYS, TAXIWAYS, APRONS, ENTRANCE ROADS, PARKING LOTS, ETC). MATERIAL TRACKED ONTO THESE AREAS MUST BE CONTINUOUSLY REMOVED DURING THE CONSTRUCTION PROJECT. PRIOR TO OPENING AIRCRAFT MOVEMENT AREAS CLOSED FOR THIS PROJECT, THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT THE SITE, INCLUDING ADJACENT PAVEMENTS AND HAUL ROUTES, IS CLEAR OF ANY FOREIGN OBJECT DEBRIS (FOD) TO THE SATISFACTION OF AIRFIELD MANAGEMENT. UPON COMPLETION OF THIS PROJECT, THE CONTRACTOR IS RESPONSIBLE FOR INSURING THAT THE SITE, INCLUDING ADJACENT PAVEMENTS AND HAUL ROUTES, IS RETURNED TO ORIGINAL CONDITION TO THE SATISFACTION OF THE AIRPORT. CONTRACTOR MAY CHOOSE TO USE TRACKOUT CONTROL DEVICES ALONG WITH SWEEPING AND VACUUMING EFFORTS TO DEAL WITH POTENTIAL FOD ISSUES. SUCH TRACKOUT DEVICES CAN BE FOUND AT WWW.TRACKOUTCONTROL.COM
OR BY SIMILAR SUPPLIERS.
B. HAZARDOUS MATERIALS (HAZMAT) MANAGEMENT, CONTRACTOR MUST CONTAIN AND CLEAN-UP SPILLS RESULTING FROM FUEL OR HYDRAULIC FLUID LEAKS. ANY SPILLS OF HAZARDOUS MATERIAL MUST BE CLEANED UP IN ACCORDANCE WITH APPLICABLE
REGULATIONS.
C. CONTRACTOR SHALL USE ALL MEANS NECESSARY TO MINIMIZE DUST DURING CONSTRUCTION OPERATIONS. IF THE AIRPORT
REQUESTS DUST CONTROL, IT SHALL BE APPLIED IMMEDIATELY.
HAUL ROUTES, PLANT SITES AND STAGING AREAS
HAUL ROUTES AND ACCESS TO THE CONSTRUCTION SITE(S) WILL BE AS SHOWN ON THE CONSTRUCTION SAFETY AND PHASING
PLAN AND AS DISCUSSED AT THE PRE-BID CONFERENCE.
CONTRACTOR IS RESPONSIBLE FOR RESTORING ALL HAUL ROADS, PLANT SITES AND STAGING AREAS TO ORIGINAL CONDITION.
THIS WILL INCLUDE BUT NOT BE LIMITED TO GRADING (FILLING IF NECESSARY) AND SEEDING ALL TURF AREAS. ANY PAVEMENT AREAS USED BY THE CONTRACTOR AS A HAUL ROUTE WHICH ARE DAMAGED WILL BE REPAVED AND/OR REMARKED AS APPROVED
BY THE BCE AT THE CONTRACTOR'S EXPENSE.
THE CONTRACTOR IS RESPONSIBLE FOR INSPECTING ALL HAUL ROUTES PRIOR TO THE START OF CONSTRUCTION. THE CONDITION OF EXISTING HAUL ROUTES SHALL BE DOCUMENTED EITHER WITH PICTURES OR VIDEO AND PROVIDED TO THE BCE PRIOR TO ANY HAULING ACTIVITIES. ANTICIPATED COSTS ASSOCIATED WITH DOCUMENTING EXISTING HAUL ROUTE CONDITION, OR RECONSTRUCTING OR RESTORING HAUL ROUTES AND STAGING AREAS SHALL BE INCIDENTAL TO THE PROJECT.
UNDERGROUND ELECTRICAL CIRCUITS
THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF EXISTING AIRFIELD UTILITIES, AND ELECTRICAL CIRCUITS, WHETHER OWNED BY THE AIRPORT OR OTHER AGENCIES OPERATING AT THE AIRPORT. LOCATIONS OF EXISTING UTILITIES SHOWN IN THE PLANS ARE BASED ON AVAILABLE AS-BUILT DATA AND ARE APPROXIMATE ONLY. THE CONTRACTOR SHALL COORDINATE THE LOCATION OF ANY CROSSING OF UNDERGROUND ELECTRICAL CIRCUITS AND UTILITIES WITH THE AIRPORT, AND FAA FACILITIES PRIOR TO THE START OF ANY CONSTRUCTION ACTIVITIES. THE CONTRACTOR SHALL PROVIDE TONING EQUIPMENT CAPABLE OF DETECTING A 60 HZ SIGNAL FOR LOCATING CABLES IN THE CONSTRUCTION AREA. THE CONTRACTOR SHALL LOCATE EXISTING UTILITIES PRIOR TO START OF CONSTRUCTION. COST OF LOCATING THE UTILITIES AND PROVIDING THE TONING EQUIPMENT SHALL
BE INCIDENTAL TO THE PROJECT.
ANY ELECTRICAL CIRCUITS TO BE CROSSED SHALL THEN BE TESTED FOR RESISTANCE TO GROUND BY THE CONTRACTOR UNDER SUPERVISION OF THE BCE AND THE READINGS RECORDED. FOLLOWING CONSTRUCTION, THE CONTRACTOR, UNDER THE SUPERVISION OF THE BCE, SHALL CHECK ALL CIRCUITS CROSSED DURING THE PROJECT. ANY CIRCUITS SHOWING A DECREASE IN RESISTANCE TO GROUND SHALL BE CORRECTED BY THE CONTRACTOR SO AS TO PROVIDE AT LEAST 50 MEGOHMS RESISTANCE IN THAT CIRCUIT. NO ADDITIONAL COMPENSATION WILL BE MADE FOR ANY CORRECTIVE ELECTRICAL WORK DUE TO CONTRACTOR'S OPERATIONS. SEE SPECIFICATIONS FOR REPAIR AND SPLICING REQUIREMENTS.
AIRPORT SECURITY
NOTE: IT IS REQUIRED THAT CONTRACTORS WILL ACCESS THE ACTIVE AIRFIELD. WORK WITHIN THE PROJECT LIMITS WILL NOT
REQUIRE COMMUNICATION WITH THE CONTROL TOWER.
THE CONTRACTOR WILL PROVIDE A GATE GUARD AT ALL POINTS OF ENTRY USED BY THE CONTRACTOR. COST OF GUARD TO BE PAID BY THE CONTRACTOR. GATES MUST BE LOCKED AT ALL TIMES WHEN NOT USED OR NOT GUARDED BY THE GATE GUARD. IF ANY CONSTRUCTION GATES ARE FOUND BY AIRFIELD STAFF TO BE OPEN AND UNATTENDED, ALLOWING UNINHIBITED ACCESS TO ANY SECURE AND/OR AIRCRAFT MOVEMENT AREAS ON THE AIRFIELD, THE CONTRACTOR MAY INCUR A FINE.
ALL COSTS INCURRED IN MEETING THE AIRFIELD SECURITY REQUIREMENTS SHALL BE CONSIDERED INCIDENTAL TO THE PROJECT.
WILDLIFE MANAGEMENT
CONTRACTOR MUST AVOID CREATING WILDLIFE HAZARDS ON THE AIRPORT SUCH AS TRASH, STANDING WATER, TALL GRASS AND SEEDS. SEEDING SHOULD COMPLY WITH THE MOST CURRENT EDITION OF FAA AC 150/5370-10.
MEETINGS AND CORRESPONDENCE
A. AIRPORT SHALL ISSUE ALL NOTAMS.
B. CONTRACTOR IS REQUIRED TO ATTEND WEEKLY COORDINATION MEETINGS AT WHICH SAFETY ISSUES WILL BE DISCUSSED.
C. ALL CONTRACTOR PERSONNEL SHALL COMPLETE THE AIRPORT'S BADGING REQUIREMENTS AND APPLICABLE SIDA/AOA/DRIVERS TRAINING COURSE. INFORMATION WILL BE SUPPLIED AT THE PRE-CONSTRUCTION MEETING.
ENFORCEMENT
A. VIOLATIONS TO THE AIRPORT OPERATIONS OR THESE RULES AND REGULATIONS, DEPENDING UPON THE SEVERITY OF THE
VIOLATION, MAY RESULT IN ONE OR MORE OF THE FOLLOWING:
1. FINES
2. A VERBAL AND/OR WRITTEN WARNING
3. REVOCATION OF AOA BADGE AND/OR VEHICLE ACCESS PERMIT
4. THE CONTRACT WORK BEING STOPPED UNTIL CORRECTIVE MEASURES ARE TAKEN TO PRECLUDE A RECURRENCE OF
THE VIOLATIONS. NO TIME EXTENSION WILL BE ISSUED DUE TO A VIOLATION.
5. REMOVAL FROM THE PROJECT
B. THE CONTRACTOR IS RESPONSIBLE FOR ALL FINES LEVIED BY THE AIRPORT, AND/OR TSA FOR VIOLATIONS OF AIRFIELD AND
SECURITY REGULATIONS.
PERMITS AND LOCAL INSPECTION FEES
THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ANY AND ALL PERMITS REQUIRED FOR THIS PROJECT. ALL COSTS
ASSOCIATED WITH PERMITS SHALL BE CONSIDERED INCIDENTAL TO THE PROJECT.
OPERATIONS/PHASING/TRAFFIC CONTROL GENERAL NOTES:
1. ALL SCHEDULING TO BE COORDINATED THROUGH THE BCE AND APPROVED BY AIRPORT OPERATIONS.
2. CONTRACTOR SHALL LOCATE ALL PUBLIC AND PRIVATE UTILITIES
2. ALL LANDSIDE AND AIRSIDE PAVEMENTS SHALL BE KEPT CLEAN OF CONSTRUCTION DEBRIS AT ALL TIMES. PAVEMENT CLEANING SHALL BE ACCOMPLISHED WITH A VACUUMING SWEEPER TRUCK (ELGIN CROSSWIND FSX OR AIRPORT APPROVED EQUAL).
3. ALL ROADS TO REMAIN OPEN TO VEHICLE TRAFFIC AT ALL TIMES.
4. CONTRACTOR SHALL SUPPLY ANY TEMPORARY STOP, SPEED LIMIT, OR ANY OTHER SIGN OR TRAFFIC CONTROL DEVICE
REQUIRED TO PERFORM CONSTRUCTION.
5. CONTRACTOR SHALL NOT PARK OR TURN AROUND CONSTRUCTION VEHICLES IN ANY AIRCRAFT ACTIVE AREAS.
6. NO PERSONAL VEHICLES WILL BE ALLOWED THROUGH AIRPORT GATES OR FENCE.
7. THE CONTRACTOR SHALL LOCATE ALL PUBLIC AND PRIVATE UTILITIES PRIOR TO BEGINNING CONSTRUCTION AND PROTECT THROUGHOUT CONSTRUCTION. ANY DAMAGE TO EXISTING UTILITIES SHALL BE REPAIRED IMMEDIATELY BY THE CONTRACTOR
AT NO COST TO THE OWNER.
8. ALL CONTRACTOR PERSONNEL SHALL COMPLETE THE AIRPORT BACKGROUND, SECURITY CHECK, AND DRIVERS TRAINING COURSE PRIOR TO BEING ABLE TO ACCESS THE SITE. THIS SHALL BE COORDINATED THROUGH AIRPORT OPERATIONS A MINIMUM OF TEN DAYS PRIOR TO THE REQUESTED DATE. FOR INFORMATION REGARDING THE TRAINING REQUIRED, SEE
"AIRPORT SECURITY" ON THE PROJECT PHASING NOTES.
9. ALL CONTRACTOR VEHICLES ON THE AIRFIELD MUST HAVE AN AIRPORT PASS ISSUED FOR AND DISPLAYED ON EACH VEHICLE'S
DASHBOARD. THIS PASS WILL BE OBTAINED AFTER PASSING REQUIRED BADGING PROCESS.
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
/1 /2
:0
:0
P M
C R e v it L o c a l\
-1
.0
-A
-C e n tr a l-m a b
.r v t
G-102
CODE ANALYSIS
SCHEDULE
M
IC
H
IG
A N
A
IR
N A
T
IO
N A
L G
U A
R D
B A
T T
L E
C R
E E
K A
N G
B B
A T
T L E
C R
E E
K M
IC
H
IG
A
N
B A
T T
L E
C R
E E
K A
N G
B R
E P
A
IR
B L D
G
F O
R C
Y B
E R
O P
E R
A T
IO
N
S S
Q U
A D
R O
N
3141900-160242.01
MAB
RCL
DECEMBER 14, 2017
JTP
ASHRAE Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings – 2013
ASHRAE Standard 62.1: Ventilation for...
ASHRAE Standard 55: Thermal...
NFPA 914: Code for Fire Protection of Historic Structures - 2014
NFPA 780: Standard for the Installation of Lightning Protection Systems -...
NFPA 285: Standard Fire Test Method for Evalution of Fire Propagation Charcteristics of Exterior Non-Load-Bearing Wall Assemblies Contain Combustible Compennts - 2012
NFPA 170: Standard for Fire Safety and Emergency Symbols - 2015
NFPA 101: Life Safety Code - 2015
NFPA 90A: Standard for the Installation of Air Conditioning and Ventilating Systems - 2015
NFPA 75: Standard for Fire Protection of Information Technology Equipment - 2017
NFPA 72: National Fire Alarm Code and Signaling Code - 2016
NFPA 70: National Electrical Code - 2017
NFPA 58: Liquefied Petroleum Gas Code - 2017
NFPA 54 (ANSI Z223.1): National Fuel Gas Code - 2015
NFPA 24: Standard for the Installation of Private Service Mains and Their Appurtenances - 2016
NFPA 13: Standard for the Installation of Sprinkler Systems - 2016
NFPA 1: Fire Code - 2015
International Code Council (ICC) Library of Codes - 2015
Public Codes:
● Applicable current ANG-ETL's as listed in ANG-ETL 15-01
ANG-ETL 15-01, Air National Guard Design Policy - May 1, 2015
Air National Guard Engineering Technical Letters (ANG-ETL)
Air National Guard Design Requirements:
Accessibility: Architectural Barriers Act (ABA) Standards (2015)
Energy Conservation: Public Law 1095-58; Energy Policy Act (EPAct of 2005), - August 8, 2005
Public Law:
UFC 3-575-01: Lightning and Static Electricity Protection Systems - July 1, 2012
UFC 3-430-01FA: Heating and Cooling Distribution Systems - July 25, 2003
UFC 3-400-02: Design: Engineering Weather Data - February 28, 2003
UFC 4-021-01: Design and O&M: Mass Notification Systems - Change 1, January 2010
UFC 4-010-02: DoD Minimum Antiterrorism Standards for Buildings (FOUO) - February 9, 2012
UFC 4-010-01: DoD Minimum Antiterrorism Standards for Buildings - Change 1, October 1, 2013
UFC 3-600-01: Fire Protection Engineering for Facilities - August 8, 2016
UFC 3-580-01: Telecommunications Building Cabling Systems Planning and Design - June 1, 2016
UFC 3-560-01: Electrical Safety, O&M - Change 5, April 14, 2015
UFC 3-550-01: Exterior Electrical Power Distribution - September 1, 2016
UFC 3-530-01: Interior and Exterior Lighting Systems and Controls - Change 3, June 1, 2016
UFC 3-520-01: Interior Electrical Systems - October 6, 2015
UFC 3-501-01: Electrical Engineering - October 6, 2015
UFC 3-420-01: Plumbing Systems - Change 10, October 26, 2015
UFC 3-410-01: Heating, Ventilating, and Air Conditioning - Change 2, October, 2015
UFC 3-401-01: Mechanical Engineering - Change 1, October, 2015
UFC 3-310-04: Seismic Design of Buildings - Change 1, June 20, 2016
UFC 3-301-01: Structural Engineering - Change 3, September 12, 2016
UFC 3-240-01: Waste Water Collection - Change 1, November 1, 2014
UFC 3-230-01: Water Storage, Distribution, and Transmission - Change 2, July 2, 2014
UFC 3-220-01: Geotechnical Engineering - November 1, 2012
UFC 3-210-10: Low Impact Development - Change 1, February 1, 2016
UFC 3-201-02: Landscape Architecture - Change 1, November, 2009
UFC 3-201-01: Civil Engineering - June 1, 2013
UFC 3-120-10: Interior Design - Change 1, July, 2007
UFC 3-110-03: Roofing - Change 1, May 22, 2014
UFC 3-101-01: Architecture - Change 3, June 20, 2016
UFC 1-200-02: High Performance and Sustainable Building Requirements - Change 3, November 7, 2014
UFC 1-200-01: General Building Requirements - August 20, 2016
Core Uniform Facility Criteria (UFC)
Department of Defense (DoD) Design Requirements:
Applicable Design Criteria and Codes:
Battle Creek, MI
W.K. Kellogg Airport
Repair Bldg. 6922 for Cyber Operations Squadron
Project Name and Location:
APPLICABLE CODES AND DESIGN CRITERIA
NFPA 70.
All references to NFPA 70 muste be considered to be references to UFC 3-501-01, which cites
Electrical Code:
UFC 3-410-01, which cites the IMC.
All references to the International Mechanical Code (IMC) must be considered to be references to
Mechanical Code:
references to UFC 1-200-02, which cites ASHRAE 90.1 and ASHRAE 189.1.
All references to the International Energy Conservation Code (IECC) must be considered to be
Energy Code:
UFC 3-410-01,which cites the IPC.
All references to the International Plumbing Code (IPC) must be considered to be referrenes to
Plumbing Code:
NFPA 54 (ANSI Z223.1) and NFPA 58.
All references to the Internatinal Fuel Gas Code (IFGC) must be considered to be references to
Fuel Gas Code:
UFC-3-600-01,which cites NFPA 1.
All references to the International Fire Code (IFC) must be considered to be references to
Fire Code:
criteria.
miltiary criteria in UFC 1-200-01. In conflicts between the IEBC and military criteria use the military through reference to core UFC, other UFC as identified in Appendix A, References, and other listed
ICC - International Existing Building Code (IEBC) as modified by Chapter 2, 3, and 4 of UFC 1-200-01
Existing Structure:
earthquake), as well as load combinations, and permitted design methodoologies.
loading requirements, minimum design loads (live and dead load, snow and wind, rain, flood, and
UFC 3-310-04 for the sesmic design of buildings. IBC Chapter 16 describes minimal structural
. Use IBC Chapter 16, Structural Design as modified by UFC 3-3010-01. Use IBC Chapter 16 and
Chapter 16 - Structural Design accessibility.
Architectrual Barriers Act (ABA) Standards (2015). Do notu use IBC, Chapter 11 for determining
. All references twithin the IBC to Chapter 11, Accessibility must be considered be references to the
Chapter 11 - Accessibility cites NFPA 101. Do not use IBC, Chapter 10 for determining means of egress.
. All references to IBC, Chapter 10 must be considered to be references to UFC-3-600-01, which
Chapter 10 - Means of Eagress criteria.
miltiary criteria in UFC 1-200-01. In conflicts between the IBC and military criteria use the military through reference to core UFC, other UFC as identified in Appendix A, References, and other listed
ICC - International Building Code (IBC) as modified by Chapter 2, 3, and 4 of UFC 1-200-01
Building Code:
Required Core Design References
ADMINISTRATION OF CODES AND DESIGN CRITERIA
of 0.1 W/cm² or as otherwise specified.
Interior Floor Finish: Floor coverings other than carpet shall have a minimum critical radiant flux
Interior Floor Finish: Carpet and carpet like interior floor finishes shall comply with ASTM D-2859
Interior Floor Finish in Exit Enclosures: Class II (Minimum)
Interior Wall and Ceiling Finish for other areas: Class B (Minimum)
Interior Wall and Ceiling Finish for Exits and Exit Corridors: Class A (Minimum)
NFPA 101, Section 39.3.3 including subsections and Section 10.2 including subsections
Interior Finishes:
X ≥ 30 ft 0 hr
10 ft ≤ 30 ft 0 hr
5 ft ≤ 10 ft 1 hr
X < 5 ft 1 hr
Group B, Type IIB Construction
Exterior Nonbearing Walls and Partitions where "x" is distance from fire separation
IBC Table 602
Fire-Resistance Rating Requirements for Exterior Walls Based on Fire Separation Distance
Roof Construction 0 hr
Floor Construction 0 hr
Interior 0 hr
Nonbearing walls and Partitions
Exterior 0 hr
Nonbearing walls and Partitions
Interior 0 hr
Exterior 0 hr
Bearing Walls
Primary structural frame 0 hr
Group B, Type IIB Construction
IBC Table 601
Fire-Resistance Rating Requirements for Building Elements (Hours)
Bldg 6922 92,000 22,789
Allowable Area (S.F.) Actual Area (S.F.)
Occupancy / Construction Type - Group B / IIB = 92,000 s.f.
IBC Table 506.2:
Building Area:
Actual
Maximum Allowed
Number of Stories
Actual 1 Stories
Maximum Allowed 4 Stories Group B
Number of Stories
Group B / IIB = 4 Stories
IBC Table 504.4:
Allowable Number of Stories Above Grade Plane
Actual 29 Feet
Maximum Allowed 75 Feet Group B
Building Height
Group B / IIB = 75 Feet High
IBC Table 504.3:
Allowable Building Height
Sprinklered: Yes
Type IIB
IBC Table 601
Construction Type:
IBC Section 304.1: Business Group B (Professional services)-Office
Building Occupancy Classifications:
FIRE PROTECTION AND LIFE SAFETY ANALYSIS
Service Sinks: 1 per floor
Drinking Fountains: 1 per 75 persons (p)
Showers - both male and female: 1 per 15 persons (p), only if need
Lavatories - both male and female: 1 per 20 persons (p), up to 100 p ; then 1 per 45 p required, one for one.
Urinals - male: Urinals may be substituted for no more than one-third of the water closets
Water Closets - both male and female: 1 per 20 persons (p), up to 100 p ; then 1 per 40 p
Business Occupancy
Minimum Number of Plumbing Fixtures
UFC 3-420-01, Section 402.1.D
Plumbing Fixtures:
dated October 31, 2008 (Revised 2015).
Department of Defense Facilities as adopted by the Deputy Secretary of Defense Memorandum
The design and construction of this facility shall comply with ABA Accessible Standards for
ABA Accessibility Standard for Department of Defense Facilities
Accessibility Requirements:
Portable fire extinguishers shall be selected, installed, inspected, and maintained in accordance with NFPA 10.
The local Authority Having Jurisdiction (AHJ) shall coordinate the (1) size, (2) type, and (3) location of portable fire extinguishers for each room in the facility.
NFPA 101, Section 9.7.4.1
Fire Extinguishers, General:
Existing Business Occupancies 300 feet
NFPA 101, Section 39.2.6.3
Travel Distance to Exits:
Existing Business Occupancies 100 feet
NFPA 101, Section 39.2.5.3.1
Common Path of Travel:
Existing Business Occupancies 50 feet
NFPA 101, Section 39.2.5.2.1
Dead-end Corridor Distance:
Total Occupants: 228
Bldg 6922 22,789 228
Floor Level Area Occupants
Business Occupancy: 1 occupant / 100 gsf
NFPA 101, Table 7.3.1.2 Occupant Load Factor:
Occupant Load:
Section 39.2.5 with subsections included.
The entire building meets the requirements for 2 exits maximum per NFPA 101, Section 39.2
2 Exits only however areas of the building can be served by a single exit per this section.
NFPA 101, Section 39.2.4 including subsections: The building does not meet the requireme...
1 Exit Only
Number of Exits:
50 or more people per NFPA 101, Section 38.2.3.2 44-inches minimum
49 or less people per NFPA 101, Section 7.3.4.1.2 36-inches minimum
Clear width of any corridor or passageway
Capacity of Means of Egress:
FIRE PROTECTION AND LIFE SAFETY ANALYSIS, CONTINUED
F
REF.REF.
UP
K - 84 LF 36"
L - 73 LF 36"
K
J
I
H
G F
A
L
C
J - 95 LF 36"
I - 73 LF 36"
26'
14'
19'
2'
38'
45'
12'
H - 123 LF 36"
G - 144 LF 36"
14'
53'
23'
54'
14'
8'
11'
B,D
E
F - 83 LF 36"
E - 90 LF 36"
61'
12'
10'
10'
46'
11'
14'
16'
14'
7'
11'
D - 62 LF 36"
6'
29'
6'
60'
7'
3'6'
8'
19'
19'
19'
12' 26'
19'
29'
21'
14'
20'
29'
A - 83 LF 36"
- 138 LF 36"C
9'
B - 77 LF 36"
765432
11'2'3'4'
A
B
AA
A.7
C
D
9'
14'
9'
9'
CEILING MOUNT / PENDANT MOUNT EXIT SIGN,
SHADED QUADRANT (S) DENOTES ILLUMINATED
FACE OF SIGN. ARROW DESIGNATES CHEVRON
INDICATING DIRECTION OF TRAVEL.
(SEE ELECTRICAL DRAWINGS FOR EXIT LIGHT
LOCATIONS)
FIRE / LIFE SAFETY / MEANS OF EGRESS LEGEND
WALL MOUNTED EXIT SIGN WITH SAME
DESIGNATIONS NOTED ABOVE.
(SEE ELECTRICAL DRAWINGS FOR EXIT LIGHT
LOCATIONS)
DIRECTION OF TRAVEL
POINT OF BEGINNING (POB) IN PATH
OF EXIT ACCESS TRAVEL DISTANCE
POINT OF EXIT
PATH OF TRAVEL
-EXIT DISTANCE,
EXIT WIDTH
X
X
POINT OF END IN PATH OF EXIT ACCESS
EXISTING WALL HUNG F.E
F.E
EXISTING FEC
1 HR RATED
1 HR RATED WALLS,FLOOR PENETRATIONS,
CEILING AND STRUCTURE ABOVE.
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
/1 /2
:0
:0
P M
C R e v it L o c a l\
-1
.0
-A
-C e n tr a l-m a b
.r v t
G-103
LIFE SAFETY PLAN
M
IC
H
IG
A N
A
IR
N A
T
IO
N A
L G
U A
R D
B A
T T
L E
C R
E E
K A
N G
B B
A T
T L E
C R
E E
K M
IC
H
IG
A
N
B A
T T
L E
C R
E E
K A
N G
B R
E P
A
IR
B L D
G
F O
R C
Y B
E R
O P
E R
A T
IO
N
S S
Q U
A D
R O
N
3141900-160242.01
MAB
RCL
DECEMBER 14, 2017
JTP
3/32" = 1'-0"1
CODE ANALYSIS AND LIFE SAFETY PLAN
STRUCTURAL DESIGN CRITERIA FOUNDATION NOTES
F-1. ALL COLUMN FOOTINGS ARE TO BE CENTERED UNDER COLUMN
CENTERLINES, UNLESS NOTED OR DETAILED OTHERWISE.
F-2. THE FOUNDATION CONTRACTOR SHALL FULLY REVIEW UNDER-GROUND
PLUMBING DRAWINGS AND SHALL COORDINATE WITH THE UNDER-GROUND
PLUMBING CONTRACTOR TO DEPRESS FOOTINGS AND PROVIDE PIPE
SLEEVES THROUGH FOUNDATION WALLS AS NECESSARY TO ACCOMMODATE
PLUMBING LINES OR TRAPS WHICH PENETRATE CONCRETE FOOTINGS OR
FOUNDATIONS.
F-3. PROVIDE PVC SLEEVES THROUGH FOUNDATION WALLS/FOOTINGS FOR PIPE,
CONDUIT, AND CABLE PENETRATIONS, INCLUDING ELECTRICAL GROUNDING
SYSTEM CABLES. SEE APPROPRIATE DRAWINGS FOR LOCATIONS/SIZES.
PLACE SLEEVES IN LOCATIONS TO AVOID DISPLACING REINFORCING STEEL.
F-4. FOOTING SUBGRADES SHALL BE CLEAN AND FREE OF DEBRIS, STANDING
WATER, AND LOOSE SOIL.
F-5. COORDINATE WITH ARCHITECTURAL AND CIVIL DRAWINGS FOR
MISCELLANEOUS FOUNDATIONS NOT SHOWN ON STRUCTURAL DRAWINGS.
F-6. CONTROL JOINTS IN THE CAST-IN-PLACE CONCRETE FOUNDATION WALLS
SHALL BE PLACED AT SPACING NOT TO EXCEED 20' O.C. OR AS LOCATED PER
DRAWINGS AND SHOULD ALIGN WITH MASONRY CONTROL JOINTS WHERE
APPLICABLE. SEE DETAIL SHEETS FOR CONTROL JOINT DETAILS. PROVIDE
VERTICAL "V" GROOVE AT ALL CONSTRUCTION AND CONTROL JOINTS.
CONTRACTOR SHALL SUBMIT PLANS OF JOINT LOCATIONS FOR APPROVAL.
F-7. SEE TYPICAL SLAB-ON-GRADE DETAILS FOR SLAB AND SUB-BASE
REQUIREMENTS. THESE WILL BE TYPICAL THROUGHOUT UNLESS NOTED
OTHERWISE.
F-8. A LEAN CONCRETE MUD SLAB 2" TO 3" THICK SHALL BE USED IN THE FOOTING
EXCAVATION IF THE BOTTOM OF THE EXCAVATION TENDS TO BECOME
MUDDY AND SOFT DUE TO CONSTRUCTION ACTIVITY. LEAN CONCRETE
SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2000 PSI.
F-9. COORDINATE GROUNDING REQUIREMENTS FOR FOUNDATION/FOOTING
REINFORCING STEEL WITH ELECTRICAL DRAWINGS. COORDINATE
INSTALLATION OF GROUNDING WIRES/EQUIPMENT WITH ELECTRICAL
CONTRACTOR PRIOR TO CASTING CONCRETE.
CONCRETE & REINFORCING STEEL NOTES
MATERIAL PROPERTIES (U.N.O.)
COMPRESSIVE STRENGTH - F'c = 4 KSI CONCRETE REINFORCEMENT - Fy = 60 KSI (A615 GR 60)
CR-1. PROVIDE ONE (1) HOOKED REINFORCING BAR IN CONCRETE FOOTING
TO SERVE AS A “CONCRETE ENCASED ELECTRODE” IN ACCORDANCE WITH
THE NATIONAL ELECTRIC CODE. COORDINATE WITH ELECTRICAL
CONTRACTOR FOR EXACT LOCATION. HOOKED REINFORCING BAR SHALL
CONFORM TO THE FOLLOWING:
A. UNCOATED, LOW-ALLOY STEEL, CONFORMING TO ASTM A706.
B. BAR SIZE NUMBER 4 HOOKED AT ONE END ONLY.
C. MINIMUM HORIZONTAL LENGTH OF REINFORCING BAR ENCASED IN
CONCRETE FOOTING SHALL BE 20’-0” AS DEFINED IN NEC, ARTICLE 250.
D. MINIMUM VERTICAL PROJECTION OF REINFORCING BAR ABOVE
CONCRETE SLAB SHALL BE 0’-6”.
E. MINIMUM COVER ALL AROUND REINFORCING BAR SHALL BE 2”.
CR-2. ALL BAR LAPS SHALL CONFORM TO ACI 318 CLASS "B" SPLICE CRITERIA. USE
TOP BAR LAP LENGTHS FOR TOP BARS IN SLABS AND BEAMS OVER 14" DEEP.
MINIMUM BAR LAPS AS FOLLOWS U.N.O.:
#3 = 1'-4" #4 = 1'-4" #5 = 1'-10" #6 = 2'-7" #7 = 4'-2" #8 = 5'-2" #9 = 6'-4" #10 = 7'-8" #11 = 9'-0"
FOR EPOXY COATED BARS, PROVIDE 1.5 TIMES THE INDICATED LAP LENGTH.
FOR TOP BARS PROVIDE 1.3 TIMES THE INDICATED LAP LENGTH.
CR-3. LAP LENGTH SHALL BE SPECIFICALLY NOTED ON SHOP DRAWINGS WHERE
MORE THAN ONE BAR MAKES UP A CONTINUOUS STRING.
CR-4. HORIZONTAL BARS SHALL BE DETAILED TO SHOW THE DISTANCE FROM AT
LEAST ONE END OF THE BAR TO THE NEAREST BUILDING GRID LINE OR
WALL.
CR-5. ALL REINFORCEMENT BARS SHALL BE FABRICATED IN ACCORDANCE WITH
THE LATEST CRSI MANUAL OF STANDARD PRACTICE AND SHALL BE CLEAN
AND FREE OF GREASE AND SCALING RUST.
CR-6. CONTINUOUS TOP AND BOTTOM BARS, WHEN SHOWN IN TRANSVERSE
SECTION ONLY, SHALL BE LAPPED AS FOLLOWS:
TOP BARS NEAR MID-SPANS; BOTTOM BARS DIRECTLY OVER SUPPORTS,
U.N.O.
CR-7. WATER STOPS SHALL BE PROVIDED IN HORIZONTAL AND VERTICAL
CONSTRUCTION JOINTS WHERE FINISHED FLOOR IS BELOW EXTERIOR
GRADE UNLESS OMISSION IS APPROVED BY THE CONTRACTING OFFICER'S
REPRESENTATIVE.
CR-8. HOOK HORIZONTAL WALL AND BEAM REINFORCING BARS AT
DISCONTINUOUS ENDS, TYPICAL U.N.O. EXTEND REINFORCEMENT TO FAR
FACE OF PIERS/PEDESTALS AND/OR COLUMNS U.N.O.
CR-9. PROVIDE HOT/COLD WEATHER PROCEDURES AND PROTECTION IN
ACCORDANCE WITH ACI RECOMMENDATIONS AND PROJECT
SPECIFICATIONS.
CR-10. CONCRETE REINFORCEMENT PROTECTION/CLEAR COVER, U.N.O.:
FOOTINGS:
BOTTOM & SIDES 3"
TOP 2"
WALLS:
EXTERIOR EXPOSURE 2"
INTERIOR EXPOSURE 1"
BEAMS/COLUMNS:
OVER TIES OR STIRRUPS 1 1/2"
ELEVATED SLABS: 1"
CR-11. PROVIDE ADDITIONAL #4 BARS AT 4'-0" LONG 1" BELOW TOP OF SLAB AT
45° TO ALL REENTRANT CORNERS,OPENINGS IN CONCRETE SLABS AND
AS INDICATED ON DRAWINGS.
CR-12. ALL CONCRETE FOUNDATION WALLS SHALL HAVE A MINIMUM OF (2) #5 BARS
CONTINUOUS TOP AND BOTTOM, UNLESS NOTED OR DETAILED OTHERWISE.
CR-13. EXTEND ALL PIER STEEL TO PROVIDE STD. HOOK UNDER FOOTING
REINFORCEMENT, UNLESS NOTED OTHERWISE.
CR-14. ALL CONCRETE DESIGN AND CONSTRUCTION SHALL CONFORM WITH THE
LOCAL BUILDING CODE REQUIREMENTS AND THOSE OF THE FOLLOWING
STANDARDS (LATEST EDITION):
"ACI 318, BUILDING CODE REQUIREMENTS FOR REINFORCED CONC."
"ACI 315, DETAILS AND DETAILING OF CONCRETE REINFORCEMENT"
"ACI 301, SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BLDGS."
"ACI 307, RECOMMENDED PRACTICE FOR CONCRETE FORM WORK"
CR-15. SEE SECTION 033000 OF SPECIFICATIONS FOR INFORMATION REGARDING
CONCRETE MIX DESIGN, TESTING, MATERIALS, AND ADMIXTURES.
CR-16. ALUMINUM CONDUIT IS NOT PERMITTED TO BE EMBEDDED IN CONCRETE.
CR-17. REFER TO FLATWORK DRAWINGS AND/OR SPECIFICATIONS FOR
SLAB-ON-GRADE FINISH TYPES AND DEPRESSIONS REQUIRED FOR MATS,
TILE, AND OTHER FINISH MATERIALS.
CR-18. PROVIDE FOOTING DOWELS TO MATCH VERTICAL WALL REINFORCING.
WHERE WALL REINFORCING IS NOT INDICATED, DOWEL FOOTING TO
FOUNDATION WALLS WITH #5 REBAR AT 16" O.C. BY 3'-0" LONG, WITH
STANDARD HOOKS EMBEDDED A MINIMUM OF 9" INTO FOOTING.
CR-19. ALL PIER FOOTINGS TO HAVE DOWELS WITH STANDARD HOOKS OF SAME
SIZE AND QUANTITY AS PIER STEEL. DOWELS TO LAP PIER STEEL AS
REQUIRED FOR A CLASS "B" TENSION SPLICE.
CR-20. ALL OPENINGS IN CONCRETE FOUNDATION WALLS ARE TO HAVE (4) #5
DIAGONAL BARS EACH FACE OF THE WALL UNLESS OTHERWISE NOTED.
BARS SHALL EXTEND 2 FEET BEYOND OPENING ON EACH SIDE.
CR-21. UNLESS NOTED OTHERWISE, THICKEN THE SLAB-ON-GRADE BENEATH
INTERIOR MASONRY PARTITIONS 8 INCHES BELOW BOTTOM OF SLAB ON
GRADE. THICKENED PORTION TO EXTEND 8 INCHES BEYOND THE FACE OF
THE
WALL ON EACH SIDE. REINFORCE THE THICKENED PORTION WITH (3) #5
CONTINUOUS, LONGITUDINAL REINFORCING BARS AND #5 TRANSVERSE
BARS AT 16" O.C., U.N.O.
CR-22. PITCH CONCRETE TO FLOOR DRAINS. COORDINATE WITH PLUMBING AND
ARCHITECTURAL DRAWINGS.
CR-23. U.N.O., PROVIDE CONTROL OR CONSTRUCTION JOINTS IN SLABS-ON-GRADE
AT 15 FOOT MAXIMUM CENTERS EACH DIRECTION. CONTRACTOR SHALL
SUBMIT PLANS OF JOINT LOCATIONS TO THE ARCHITECT/ENGINEER FOR
APPROVAL PRIOR TO CASTING SLABS-ON GRADE. COORDINATE WITH
ARCHITECTURAL DRAWINGS AND FLOOR FINISHES SUCH AS TILE AND
TERRAZZO.
CR-24. ALL DOWELS INTO EXISTING CONCRETE OR SOLID MASONRY TO BE EPOXY
ANCHORED WITH HILTI HIT-RE 500-SD ADHESIVE OR EQUIVALENT, (UNLESS
INDICATED OTHERWISE.)
GENERAL NOTES
G-1. FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO START
OF CONSTRUCTION - RESOLVE ANY DISCREPANCY WITH CONTRACTING
OFFICER'S REPRESENTATIVE.
G-2. FOR CLARITY, ALL EXTERIOR SLABS AND SIDEWALKS MAY NOT BE SHOWN.
FOR EXACT DIMENSIONS, LOCATIONS, JOINTS AND SCORE LINES, SEE
ARCHITECTURAL AND/OR CIVIL DRAWINGS.
G-3. VERIFY ALL SIZES, WEIGHTS AND LOCATIONS OF MECHANICAL AND
ELECTRICAL EQUIPMENT, ROOF PENETRATIONS, DUCTS, ETC. WITH
MECHANICAL AND ELECTRICAL CONTRACTORS AND FIELD CONDITIONS.
G-4. DETAILS MARKED "TYPICAL" MAY OR MAY NOT BE CUT ON PLANS, BUT
SHALL APPLY UNLESS NOTED OTHERWISE.
G-5. STRUCTURAL SYSTEM IS DESIGNED TO WORK AS A COMPLETED SYSTEM,
ANY SHORING OR BRACING NECESSARY DURING CONSTRUCTION SHALL
BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.
G-6. SEE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING PLANS
FOR SLEEVES, INSERTS, ETC. NOT SHOWN ON STRUCTURAL PLANS.
G-7. NO PIPES OR SLEEVES FOR MECHANICAL TRADES SHALL PASS THROUGH
STRUCTURAL MEMBERS WITHOUT APPROVAL OF THE CONTRACTING OFFICER'S
REPRESENTATIVE
G-8. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL SITE SAFETY AND ALL
ACCIDENTS WHICH RESULT IN DEATH, PERSONAL INJURY, OR DAMAGE TO
PROPERTY ARISING OUT OF OR IN CONNECTION WITH THE PERFORMANCE
OF THE WORK.
G-9. CONTRACTOR SHALL POST LIVE LOADS PER SECTION 106.1 OF THE
GOVERNING CODE.
G-10. SECTIONS, DETAILS, AND NOTES SHOWN ON THE DRAWINGS ARE INTENDED
TO BE TYPICAL AND SHALL APPLY TO SIMILAR CONDITIONS ELSEWHERE,
UNLESS OTHERWISE SHOWN.
DO NOT SCALE DRAWINGS
EARTHWORK NOTES
EW-1. SEE GEOTECHNICAL REPORT AND SPECIFICATIONS FOR DEFINITION OF
MATERIALS AND COMPACTION REQUIREMENTS.
EW-2. U.N.O., THE CONTRACTOR SHALL RETAIN AN INDEPENDENT, QUALIFIED
GEOTECHNICAL ENGINEERING FIRM/TESTING AGENCY TO IDENTIFY AREAS
OF POOR SOILS, TO MONITOR PROPER SUBGRADE PREPARATIONS AND TO
OVERSEE AND TEST THE PLACEMENT OF COMPACTED FILL MATERIAL.
EW-3. ALL SUBTERRANEAN STRUCTURES, UTILITIES, PIPING, ETC. IIN THE AREA
OF EXCAVATIONS TO BE LOCATED AND MARKED BY CONTRACTOR PRIOR
TO EARTH REMOVAL WORK. CONTRACTOR TO MAINTAIN MARKERS UNTIL
EXCAVATION ACTIVITIES HAVE CEASED. IF UNDERGROUND UTILITY
CONFLICTS ARE DISCOVERED BEFORE OR ENCOUNTERED DURING
EXCAVATION, NOTIFY THE CONTRACTING OFFICER'S REPRESENTATIVE
IMMEDIATELY.
EW-4. BEFORE PLACING FOOTINGS, FOUNDATIONS OR SLAB-ON-GRADE, THE
SUB-GRADE SHALL BE PREPARED AND INSPECTED AS REQUIRED BY THE
SPECIFICATIONS.
EW-5. REFERENCE THE GEOTECHNICAL REPORT INCLUDED IN THE PROJECT
MANUAL FOR…