B.08.02.2.3 ar123_Att_3_Architectural Drawings.pdf

PDF 3 MB Posted

Attached to
FY19 Command Control Facility and VMF, Chad
Solicitation number
W912GB19R0043
Issued by

About this file

Solicitation Attachments

View the file

Other files

File Type Posted
B.08.03_W912GB19R0043-0005_Extension.pdf PDF
B.08.04_ATTACHMENT_1__SOW_ar104_01010_2019-06-21_REVISED.pdf PDF
B.08.04_ATTACHMENT_2__SOW_ar123_01010_2019-06-21_REVISED.pdf PDF
B.08.04_W912GB19R0043-0004_SOWs_Updates.pdf PDF
B.08.03_W912GB19R0043-0003_Extension.pdf PDF
A.02.16_ar104_Att_6_NDJAMENA_C2_Location.pdf PDF
B.08.02_Att9_C2_VMF_Combined_-_MP_29_May_2019.docx DOCX document
ar104_01010_2019-05-29_Revised.docx DOCX document
ar123_01010_2019-05-24_Revised.docx DOCX document
B.08.03_W912GB19R0043-0002_SOWs_Updates,_Site_Visit,_Instructions.pdf PDF
B.01.03_W912GB19R0043_Amendment_0001.pdf PDF
B.08.02.2 SOW ar123_01010_2019-04-12.pdf PDF
B.08.02.1 SOW ar104_01010_12 APR 2019 Update.pdf PDF
B.08.02.1.1 ar104_Att 1_Conceptual Site Plan.pdf PDF
B.08.02.4 Past Performance Questionnaire - 19R0043.pdf PDF
B.08.02.6 Arr 6 - BLG Template 19R0043.docx DOCX document
B.08.02.1.3 ar104_Att 3_Room Data Sheets.pdf PDF
B.08.02.2.5 ar123 Att. 5 Structural Calculations Guideline.pdf PDF
B.08.02.2.2 ar123_Att_2_Conceptual Site Plan 2019-04-12.pdf PDF
B.08.02.2.1 ar123_Att1_LocationMap.pdf PDF
B.08.02.2.6 ar123_Att_6_Geotechnical Report for Adjacent Site.pdf PDF
B.08.02_W912GB19R0043_RFP_Faya_VMF_and_NDjamena_C2.pdf PDF
B.08.02.2.7 ar123_Att_7 Existing Generator Pad As-Builts.pdf PDF
B.08.02.1.5 ar104_Att 5_NASS BYOT ASSEMBLY INSTRUCTIONS.PDF PDF
B.08.02.1.2 ar104_Att 2_Conceptual Floor Plan_12 APR 19_update.pdf PDF
B.08.02.7 Att 7 Specification Binder.pdf PDF
B.08.02.1.4 ar104_Att 4_Structural Calculations Guideline.pdf PDF
B.08.02.2.4 ar123_Att_4 Vehicle for planning.pdf PDF
B.08.02.3 Preproposal Conf Attendee Info Sheet.xlsx XLSX spreadsheet
B.08.02.5 Att 5 - BLA Template 19R0043.docx DOCX document
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

U P

5.

m 5.

m

5.

m

.5 m

²

A D

M

IN

./O F

F

IE

C S

P A

C E

8.

m

²

G A

R A

G E

INSPECTION PIT

3.

m 3.

m

3.

m 3.

m

20.10 m

F U

R N

IT

U

R E

N O

T

IN

C O

N T

R A

C T

C O

N C

R E

T E

A P

R O

N

C O

N C

R E

T E

A P

R O

N

2.

m

1.30 m

2.

m

1.30 m

E X

IT

O

N

LY

E X

IT

O

N

LY

.7 m

²

S T

A

IR

S

.7 m

²

S T

A

IR

S

B O

LL

A

R D

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I '

D

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

A-101

F

IR

S T

F

LO

O R

P

LA

N

X X

X Y

Y Y

A ut ho r

X X

X Y

Y Y

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

-1

F

IR

S T

F

LO

O R

E7EDGMCB

Typewritten Text

CONTRACTOR TO PROVIDE

ON THE FIRST FLOOR:

- 2 SHOWER ROOMS WITH

LOCKER AND DRESSING SPACE

AND 2 SHOWERS, 90 X 90 CM EACH

- 2 TOILET ROOMS 1 TOILET 1 SINK

EACH

.5 m

²

A D

M

IN

S

T O

R A

G E

.7 m

²

S T

A

IR

S

.7 m

²

S T

A

IR

S

F U

R N

IT

U

R E

N O

T

IN

C O

N T

R A

C T

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I '

D

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

A-102

S E

C O

N D

F

LO

O R

P

LA

N

X X

X Y

Y Y

A ut ho r

X X

X Y

Y Y

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

-1

S E

C O

N D

F

LO

O R

E7EDGMCB

Rectangle

E7EDGMCB

Typewritten Text

GENERAL PURPOSE

MULTI-FUNCTIONAL SPACE

FIRST FLOOR

0.00 m

ROOF

5.75 m

TOF

-0.91 m

SECOND FLOOR

2.88 m

FIRST FLOOR

0.00 m

ROOF

5.75 m

TOF

-0.91 m

SECOND FLOOR

2.88 m

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I '

D

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

A-201

N O

R T

H A

N D

S O

U T

H E

L E V

A T

IO

N

S

X X

X Y

Y Y

A ut ho r

X X

X Y

Y Y

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

1 : 50A-201

1 ELEVATION NORTH

1 : 50A-201

2 ELEVATION SOUTH

FIRST FLOOR

0.00 m

ROOF

5.75 m

TOF

-0.91 m

SECOND FLOOR

2.88 m

FIRST FLOOR

0.00 m

ROOF

5.75 m

TOF

-0.91 m

SECOND FLOOR

2.88 m

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I '

D

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

A-202

E A

S T

A N

D W

E S

T E

LE

V

A T

IO

N

S

X X

X Y

Y Y

A ut ho r

X X

X Y

Y Y

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

1 : 50A-202

1 ELEVATION EAST

1 : 50A-202

2 ELEVATION WEST

File details come from the government source that posted it.