05_51_33.pdf

PDF 43 KB Posted

Attached to
General Purpose Storage Building, Watervliet, NY Federal contract opportunity
Solicitation number
W912DS-18-B-0014
Issued by
Department of the Army Corps of Engineers Engineering District New York

About this file

05 51 33

View the file

Other files for this federal contract opportunity

Other files attached to General Purpose Storage Building, Watervliet, NY, newest first.
File Type Posted
Bid_Abstract_-__W912DS18B0014.pdf PDF
EP-601_(revision_2).pdf PDF
W912DS18B0014-0007.pdf PDF
A-501.pdf PDF
A-601.pdf PDF
photo 9.jpg JPG image
03_30_00._00_10.pdf PDF
A-101.pdf PDF
photo 5.jpg JPG image
photo 14.jpg JPG image
photo 13.jpg JPG image
M-101.pdf PDF
W912DS18B0014-0007.pdf PDF
photo 10.jpg JPG image
A-502.pdf PDF
A-201.pdf PDF
C-505__24JUL18.pdf PDF
10_44_16.pdf PDF
photo 11.jpg JPG image
S-001.pdf PDF
G-003.pdf PDF
EP-602_-_PANEL_SCHEDULES_(24jul18).pdf PDF
photo 22.jpg JPG image
photo 19.jpg JPG image
Watervliet_Arsenal_1A1_Approvals.pdf PDF
A-401.pdf PDF
photo 3.jpg JPG image
SUBMITTAL_REGISTER.PDF PDF
photo 12.jpg JPG image
EP-101_24jul18.pdf PDF
W912DS18B0014-0006.pdf PDF
12_21_00.pdf PDF
41_22_13.14.pdf PDF
03_33_00.pdf PDF
22_00_00.pdf PDF
08_71_00.pdf PDF
W912DS18B0014-0005_-_Revised_7.27.pdf PDF
08_33_23.pdf PDF
00_73_00.00_18.pdf PDF
09_30_10.pdf PDF
C-101_AMENDMENT.pdf PDF
S-404_Watervliet_Warehouse_Loading_Dock_Amendment.pdf PDF
W912DS18B0014-0005.pdf PDF
W912DS18B0014_-_0003.pdf PDF
WVA_Storage_Warehouse_sign_in_sheet.pdf PDF
specification_41_22_13.14.pdf PDF
W912DS18B0014_-_0001.pdf PDF
W912DS18B0014.pdf PDF
WATERVLIETWHSE_100PCNT_SPECS_RTA.pdf PDF
75906_WVA_Warehs_Dwg_RTA.pdf PDF
Show all 50

General Purpose Storage Building, Watervliet, NY has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WATERVLI ET WAREHOUSE WATERVLIETWHSE

AMENDMENT 1

SECTI ON 05 51 33

METAL LADDERS

02/16

PART 1 GENERAL

1. 1 REFERENCES

The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o wi t hi n t he t ext by t he basi c desi gnat i on onl y.

AMERI CAN LADDER I NSTI TUTE ( ALI )

ALI A14. 3 ( 2008) St andar d f or Fi xed Ladder s and Saf et y Requi r ement s

AMERI CAN WELDI NG SOCI ETY ( AWS)

AWS D1. 1/ D1. 1M ( 2015; Er r at a 1 2015; Er r at a 2 2016) St r uct ur al Wel di ng Code - St eel

ASTM I NTERNATI ONAL ( ASTM)

ASTM A36/ A36M ( 2014) St andar d Speci f i cat i on f or Car bon St r uct ur al St eel

ASTM A47/ A47M ( 1999; R 2014) St andar d Speci f i cat i on f or Fer r i t i c Mal l eabl e I r on Cast i ngs

ASTM A500/ A500M ( 2013) St andar d Speci f i cat i on f or Col d- For med Wel ded and Seaml ess Car bon St eel St r uct ur al Tubi ng i n Rounds and Shapes

ASTM A53/ A53M ( 2012) St andar d Speci f i cat i on f or Pi pe, St eel , Bl ack and Hot - Di pped, Zi nc- Coat ed, Wel ded and Seaml ess

ASTM B108/ B108M ( 2015) St andar d Speci f i cat i on f or Al umi num- Al l oy Per manent Mol d Cast i ngs

ASTM B209 ( 2014) St andar d Speci f i cat i on f or Al umi num and Al umi num- Al l oy Sheet and Pl at e

ASTM B221 ( 2014) St andar d Speci f i cat i on f or Al umi num and Al umi num- Al l oy Ext r uded Bar s, Rods, Wi r e, Pr of i l es, and Tubes

ASTM B26/ B26M ( 2014; E 2015) St andar d Speci f i cat i on f or Al umi num- Al l oy Sand Cast i ngs

ASTM D1187/ D1187M ( 1997; E 2011; R 2011) Asphal t - Base Emul si ons f or Use as Pr ot ect i ve Coat i ngs f or Met al

SECTI ON 05 51 33 Page 1

07/ 27/ 18 9: 59 AM

MASTER PAI NTERS I NSTI TUTE ( MPI )

MPI 79 ( Oct 2009) Al kyd Ant i - Cor r osi ve Met al Primer

SOCI ETY FOR PROTECTI VE COATI NGS ( SSPC)

SSPC SP 3 ( 1982; E 2004) Power Tool Cl eani ng

SSPC SP 6/ NACE No. 3 ( 2007) Commer ci al Bl ast Cl eani ng

U. S. NATI ONAL ARCHI VES AND RECORDS ADMI NI STRATI ON ( NARA)

29 CFR 1910. 27 Fi xed Ladder s

1. 2 SUBMITTALS

Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;

submi t t al s not havi ng a " G" desi gnat i on ar e f or i nf or mat i on onl y. When used, a desi gnat i on f ol l owi ng t he " G" desi gnat i on i dent i f i es t he of f i ce t hat wi l l r evi ew t he submi t t al f or t he Gover nment . Submi t t al s wi t h an " S" ar e f or i ncl usi on i n t he Sust ai nabi l i t y Not ebook, i n conf or mance wi t h Section 01 33 29 SUSTAI NABI LI TY REPORTI NG. Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00 SUBMI TTAL PROCEDURES:

SD- 02 Shop Dr awi ngs

Ladders , I nst al l at i on Dr awi ngs

SD- 03 Pr oduct Dat a

Ladders

Ladder Saf et y Devi ces

SD- 07 Cer t i f i cat es

Fabr i cat or Cer t i f i cat i on f or Ladder Assembl y

Fabr i cat or Cer t i f i cat i on f or Shi ps Ladder Assembl y

1. 3 CERTIFICATES

Provide f abr i cat or cer t i f i cat i on f or l adder assembl y st at i ng t hat t he l adder and associ at ed component s have been f abr i cat ed accor di ng t o t he r equi r ement s of 29 CFR 1910. 27.

Provide f abr i cat or cer t i f i cat i on f or shi ps l adder assembl y st at i ng t hat t he shi ps l adder and associ at ed component s have been f abr i cat ed accor di ng t o t he r equi r ement s of 29 CFR 1910. 27.

1. 4 QUALI FI CATI ON OF WELDERS

Qual i f y wel der s i n accor dance wi t h AWS D1. 1/ D1. 1M. Use pr ocedur es, mat er i al s, and equi pment of t he t ype r equi r ed f or t he wor k.

1. 5 DELI VERY, STORAGE, AND PROTECTI ON

Pr ot ect f r om cor r osi on, def or mat i on, and ot her t ypes of damage. St or e

SECTI ON 05 51 33 Page 2 i t ems i n an encl osed ar ea f r ee f r om cont act wi t h soi l and weat her . Remove and r epl ace damaged i t ems wi t h new i t ems.

PART 2 PRODUCTS

2. 1 MATERIALS

2. 1. 1 St r uct ur al Car bon St eel

ASTM A36/ A36M.

2. 1. 2 St r uct ur al Tubi ng

ASTM A500/ A500M.

2. 1. 3 St eel Pi pe

ASTM A53/ A53M, Type E or S, Gr ade B.

2. 1. 4 Fi t t i ngs f or St eel Pi pe

St andar d mal l eabl e i r on f i t t i ngs ASTM A47/ A47M.

2. 1. 5 Al umi num Al l oy Pr oduct s

Conf or m t o ASTM B209 f or sheet pl at e, ASTM B221 f or ext r usi ons and ASTM B26/ B26M or ASTM B108/ B108M f or cast i ngs, as appl i cabl e. Pr ovi de al umi num ext r usi ons at l east 1/ 8 i nch t hi ck and al umi num pl at e or sheet at least 0. 050 i nch t hi ck.

2. 2 FABRI CATI ON FI NI SHES

2. 2. 1 Galvanizing

Hot - di p gal vani ze i t ems speci f i ed t o be zi nc- coat ed, af t er f abr i cat i on wher e pr act i cabl e. Gal vani z i ng: ASTM A123/ A123M, ASTM A153/ A153M, ASTM A653/ A653M or ASTM A924/ A924M, G90, as appl i cabl e.

2. 2. 2 Galvanize

Anchor bol t s, washer s, and par t s or devi ces necessar y f or pr oper i nst al l at i on, unl ess i ndi cat ed ot her wi se.

2. 2. 3 Repai r of Zi nc- Coat ed Sur f aces

Repai r damaged sur f aces wi t h gal vani z i ng r epai r met hod and pai nt conf or mi ng t o ASTM A780/ A780M or by appl i cat i on of st i ck or t hi ck past e mat er i al speci f i cal l y desi gned f or r epai r of gal vani z i ng, as appr oved by Cont r act i ng Of f i cer . Cl ean ar eas t o be r epai r ed and r emove sl ag f r om wel ds. Heat sur f aces t o whi ch st i ck or past e mat er i al i s appl i ed, wi t h a t or ch t o a t emper at ur e suf f i c i ent t o mel t t he met al l i cs i n st i ck or past e;

spr ead mol t en mat er i al uni f or ml y over sur f aces t o be coat ed and wi pe of f excess mat er i al .

2. 2. 1 Shop Cl eani ng and Pai nt i ng

2. 2. 1. 1 Sur f ace Pr epar at i on

Bl ast c l ean sur f aces i n accor dance wi t h SSPC SP 6/ NACE No. 3. Sur f aces

SECTI ON 05 51 33 Page 3 t hat wi l l be exposed i n spaces above cei l i ng or i n at t i c spaces, cr awl spaces, f ur r ed spaces, and chases may be cl eaned i n accor dance wi t h SSPC SP 3 i n l i eu of bei ng bl ast c l eaned. Wash cl eaned sur f aces whi ch become cont ami nat ed wi t h r ust , di r t , oi l , gr ease, or ot her cont ami nant s wi t h sol vent s unt i l t hor oughl y c l ean.

2. 2. 1. 2 Pr et r eat ment , Pr i mi ng and Pai nt i ng

Appl y pr et r eat ment , pr i mer , and pai nt i n accor dance wi t h manuf act ur er ' s pr i nt ed i nst r uct i ons. On sur f aces conceal ed i n t he f i ni shed const r uct i on or not accessi bl e f or f i ni sh pai nt i ng, appl y an addi t i onal pr i me coat t o a mi ni mum dr y f i l m t hi ckness of 1. 0 mi l . Ti nt addi t i onal pr i me coat wi t h a smal l amount of t i nt i ng pi gment .

2. 3 LADDERS

Fabr i cat e ver t i cal l adder s conf or mi ng t o 29 CFR 1910. 27and Sect i on 5 of ALI A14. 3. Use 2 1/ 2 by 3/ 8 i nch st eel f l at s f or st r i nger s and 3/ 4 i nch di amet er st eel r ods f or r ungs. Rungs must not be l ess t han 16 i nches wi de, spaced one f oot apar t , pl ug wel ded or shoul der ed and headed i nt o st r i nger s. I nst al l l adder s so t hat t he di st ance f r om t he r ungs t o t he f i ni shed wal l sur f ace wi l l not be l ess t han 7 i nches. Pr ovi de heavy cl i p angl es r i vet ed or bol t ed t o t he st r i nger and dr i l l ed f or not l ess t han t wo 1/ 2 i nch di amet er expansi on bol t s as i ndi cat ed. Pr ovi de i nt er medi at e c l i p angl es not over 48 i nches on cent er s. The t op r ung of t he l adder must be l evel wi t h t he t op of t he access l evel , par apet or l andi ng ser ved by t he l adder except f or hat ches or wel l s. Ext end t he si de r ai l s of t hr ough or s i de st ep l adder s 42 i nches above t he access l evel . Pr ovi de l adder access pr ot ect i ve swi ng gat es at t he t op of access/ egr ess l evel . The dr awi ngs must i ndi cat e l adder l ocat i ons and det ai l s of cr i t i cal di mensi ons and materials.

2. 3. 1 Ladder Cages

Conf or m t o 29 CFR 1910. 27. Fabr i cat e 2 by 1/ 4 i nchhor i zont al bands and 1 1/ 2 by 3/ 16 i nch ver t i cal bar s. Pr ovi de at t achment s f or f ast eni ng bands t o t he s i de r ai l s of l adder s or di r ect l y t o t he st r uct ur e. Pr ovi de and f ast en ver t i cal bar s on t he i nsi de of t he hor i zont al bands. Ext end cages not l ess t han 27 i nches or mor e t han 28 i nches f r om t he cent er l i ne of t he r ungs, excl udi ng t he f l ar e at t he bot t om of t he cage, and not l ess t han 27 inches i n wi dt h. Cl ear t he i nsi de of t he cage of pr oj ect i ons.

2. 3. 1 Ladder Saf et y Devi ces

Conf or m t o 29 CFR 1910. 27 and Sect i on 7 of ALI A14. 3. I nst al l l adder saf et y devi ces on l adder s over 20 f eet l ong or mor e. The l adder saf et y syst ems must meet t he desi gn r equi r ement of t he l adder s whi ch t hey ser ve.

The l adder saf et y syst em must be capabl e of sust ai ni ng a st at i c l oad of 1, 000 pounds.

PART 3 EXECUTI ON

3. 1 GENERAL I NSTALLATI ON REQUI REMENTS

I nst al l i t ems at l ocat i ons i ndi cat ed, accor di ng t o manuf act ur er ' s i nst r uct i ons. Ver i f y al l measur ement s and t ake al l f i el d measur ement s necessar y bef or e f abr i cat i on. Pr ovi de Exposed f ast eni ngs of compat i bl e mat er i al s, gener al l y mat chi ng i n col or and f i ni sh, and har moni ze wi t h t he mat er i al t o whi ch f ast eni ngs ar e appl i ed. I ncl ude mat er i al s and par t s

SECTI ON 05 51 33 Page 4 necessar y t o compl et e each i t em, even t hough such wor k i s not def i ni t el y shown or speci f i ed. Poor mat chi ng of hol es f or f ast ener s wi l l be cause f or r ej ect i on. Conceal f ast eni ngs wher e pr act i cabl e. Thi ckness of met al and det ai l s of assembl y and suppor t s must pr ovi de st r engt h and st i f f ness.

For med j oi nt s exposed t o t he weat her t o excl ude wat er . I t ems l i s t ed bel ow r equi r e addi t i onal pr ocedur es.

3. 2 WORKMANSHIP

Met al wor k must be wel l f or med t o shape and si ze, wi t h shar p l i nes and angl es and t r ue cur ves. Dr i l l i ng and punchi ng must pr oduce cl ean t r ue l i nes and sur f aces. Cont i nuousl y wel d al ong t he ent i r e ar ea of cont act .

Do not t ack wel d exposed connect i ons of wor k i n pl ace. Gr i d smoot h exposed wel ds. Pr ovi de smoot h f i ni sh on exposed sur f aces of wor k i n pl ace, unl ess ot her wi se appr oved. Wher e t i ght f i t s ar e r equi r ed, mi l l j oi nt s. Cope or mi t er cor ner j oi nt s, wel l f or med, and i n t r ue al i gnment .

I nst al l i n accor dance wi t h manuf act ur er ' s i nst al l at i on i nst r uct i ons and appr oved dr awi ngs, cut s, and det ai l s.

3. 3 ANCHORAGE, FASTENI NGS, AND CONNECTI ONS

Pr ovi de anchor age wher e necessar y f or f ast eni ng met al i t ems secur el y i n pl ace. I ncl ude f or anchor age not ot her wi se speci f i ed or i ndi cat ed sl ot t ed i nser t s, expansi on anchor s, and powder - act uat ed f ast ener s, when appr oved f or concr et e; t oggl e bol t s and t hr ough bol t s f or masonr y; machi ne bol t s, car r i age bol t s and powder - act uat ed t hr eaded st uds f or st eel ; t hr ough bol t s, l ag bol t s, and scr ews f or wood. Do not use wood pl ugs i n any mat er i al . Pr ovi de non- f er r ous at t achment s f or non- f er r ous met al . Make exposed f ast eni ngs of compat i bl e mat er i al s, gener al l y mat chi ng i n col or and f i ni sh, t o whi ch f ast eni ngs ar e appl i ed. Conceal f ast eni ngs wher e practicable.

3. 4 WELDING

Per f or m wel di ng, wel di ng i nspect i on, and cor r ect i ve wel di ng, i n accor dance with AWS D1. 1/ D1. 1M. Use cont i nuous wel ds on al l exposed connect i ons.

Gr i nd v i s i bl e wel ds smoot h i n t he f i ni shed i nst al l at i on.

3. 5 FINISHES

3. 5. 1 Di ssi mi l ar Mat er i al s

Wher e di ssi mi l ar met al s ar e i n cont act , pr ot ect sur f aces wi t h a coat conf or mi ng t o MPI 79 t o pr event gal vani c or cor r osi ve act i on. Wher e al umi num i s i n cont act wi t h concr et e, pl ast er , mor t ar , masonr y, wood, or absor pt i ve mat er i al s subj ect t o wet t i ng, pr ot ect wi t h ASTM D1187/ D1187M, asphal t - base emul si on.

3. 5. 2 Fi el d Pr epar at i on

Remove r ust pr event i ve coat i ng j ust pr i or t o f i el d er ect i on, usi ng a r emover appr oved by t he r ust pr event i ve manuf act ur er . Sur f aces, when assembl ed, must be f r ee of r ust , gr ease, di r t and ot her f or ei gn mat t er .

3. 5. 3 Envi r onment al Condi t i ons

Do not c l ean or pai nt sur f ace when damp or exposed t o f oggy or r ai ny weat her , when met al l i c sur f ace t emper at ur e i s l ess t han 5 degr ees F above t he dew poi nt of t he sur r oundi ng ai r , or when sur f ace t emper at ur e i s bel ow

SECTI ON 05 51 33 Page 5

45 degr ees F or over 95 degr ees F, unl ess appr oved by t he Cont r act i ng Officer.

3. 6 LADDERS

Secur e t o t he adj acent const r uct i on wi t h t he c l i p angl es at t ached t o t he st r i nger . Secur e t o masonr y or concr et e wi t h not l ess t han t wo 1/ 2 i nch di amet er expansi on bol t s. I nst al l i nt er medi at e c l i p angl es not over 48 inches on cent er . I nst al l br acket s as r equi r ed f or secur i ng of l adder s wel ded or bol t ed t o st r uct ur al st eel or bui l t i nt o t he masonr y or concr et e. Ends of l adder s must not r est upon f l oor .

- - End of Sect i on - -

SECTI ON 05 51 33 Page 6

05 51 33
METAL LADDERS
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 CERTIFICATES
1.4 QUALIFICATION OF WELDERS
1.5 DELIVERY, STORAGE, AND PROTECTION
PART 2 PRODUCTS
2.1 MATERIALS
2.1.1 Structural Carbon Steel
2.1.2 Structural Tubing
2.1.3 Steel Pipe
2.1.4 Fittings for Steel Pipe
2.1.5 Aluminum Alloy Products
2.2 FABRICATION FINISHES
2.2.1 Shop Cleaning and Painting
2.2.1.1 Surface Preparation
2.2.1.2 Pretreatment, Priming and Painting
2.3 LADDERS
2.3.1 Ladder Safety Devices
PART 3 EXECUTION
3.1 GENERAL INSTALLATION REQUIREMENTS
3.2 WORKMANSHIP
3.3 ANCHORAGE, FASTENINGS, AND CONNECTIONS
3.4 WELDING
3.5 FINISHES
3.5.1 Dissimilar Materials
3.5.2 Field Preparation
3.5.3 Environmental Conditions

3.6 LADDERS

08 33 23
OVERHEAD COILING DOORS
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 QUALITY ASSURANCE
1.3.1 Air Leakage / Infiltation

1.4 DELIVERY, STORAGE, AND HANDLING

PART 2 PRODUCTS
2.1 SYSTEM DESCRIPTION
2.1.1 Design Requirements
2.1.1.1 Overhead Coiling Door Detail Shop Drawings
2.1.2 Performance Requirements
2.1.2.1 Wind Loading
2.1.2.2 Operational Cycle Life
2.2 COMPONENTS
2.2.1 Overhead Coiling Doors
2.2.1.1 Curtain Materials and Construction
2.2.1.2 Insulated Curtains
2.2.1.3 Curtain Bottom Bar
2.2.1.4 Vision Panels
2.2.1.5 Locks
2.2.1.6 Weather Stripping
2.2.1.7 Locking Devices
2.2.1.8 Safety Interlock
2.2.1.9 Overhead Drum
2.2.1.10 Slats
2.2.1.11 Air Leakage / Infiltation
2.2.2 Hardware
2.2.2.1 Guides
2.2.2.2 Equipment Supports
2.2.2.3 Hood
2.2.3 Counterbalancing Mechanism
2.2.3.1 Brackets
2.2.3.2 Counterbalance Barrels
2.2.3.3 Torsion Rod for Counter Balance
2.2.3.4 Counterbalance Shaft Assembly
2.2.4 Manual Door Operators
2.2.4.1 Manual Chain-Hoist Door Operators
2.2.5 Electric Door Operators
2.2.5.1 Door-Operator Types
2.2.5.2 Electric Motors
2.2.5.3 Motor Bearings
2.2.5.4 Motor Starters, Controls, and Enclosures
2.2.5.5 Control Enclosures
2.2.5.6 Transformer
2.2.5.7 Safety-Edge Device
2.2.5.8 Speed-Reduction Units
2.2.5.9 Chain Drives
2.2.5.10 Brakes
2.2.5.11 Clutches
2.2.5.12 Weather/Smoke Seal Sensing Edge

2.2.6 Factory Applied Surface Finishing for Doors and Frames

2.3 BASIS OF DESIGN

PART 3 EXECUTION
3.1 INSTALLATION
3.1.1 Field Painted Finish
3.2 ADJUSTING AND CLEANING
3.2.1 Acceptance Provisions
3.2.1.1 Maintenance and Adjustment
3.3 CLOSEOUT ACTIVITIES
3.3.1 Warranty
3.3.2 Operation And Maintenance
08 71 00
DOOR HARDWARE
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 SHOP DRAWINGS
1.4 PRODUCT DATA
1.5 HARDWARE SCHEDULE
1.6 KEY BITTING CHART REQUIREMENTS
1.6.1 Requirements
1.7 QUALITY ASSURANCE
1.7.1 Hardware Manufacturers and Modifications
1.7.2 Key Shop Drawings Coordination Meeting

1.8 DELIVERY, STORAGE, AND HANDLING

PART 2 PRODUCTS
2.1 TEMPLATE HARDWARE
2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS
2.3 HARDWARE ITEMS
2.3.1 Hinges
2.3.2 Locks and Latches
2.3.2.1 Mortise Locks and Latches
2.3.2.2 Auxiliary Locks
2.3.3 Exit Devices
2.3.4 Exit Locks With Alarm
2.3.5 Cylinders and Cores
2.3.5.1 High Security Cylinders
2.3.6 Push Button Mechanisms
2.3.7 Electrified Hardware
2.3.7.1 Electrified Mortise Locks
2.3.7.1.1 Power Transfer Hinges
2.3.7.2 Card Readers and Keypad Access Control Hardware
2.3.7.3 Power Operated Pedestrian Door Hardware
2.3.7.4 Release Devices
2.3.7.5 Electromagnetic Locks
2.3.7.5.1 Armature
2.3.7.5.2 Tamper Resistance
2.3.7.5.3 Mounting Method
2.3.8 Keying System
2.3.9 Lock Trim
2.3.9.1 Lever Handles
2.3.9.2 Texture
2.3.10 Keys
2.3.11 Closers
2.3.11.1 Identification Marking
2.3.12 Overhead Holders
2.3.13 Door Protection Plates
2.3.13.1 Sizes of Armor and Kick Plates
2.3.13.2 Edge Guards
2.3.14 Door Stops and Silencers
2.3.15 Thresholds
2.3.16 Weatherstripping Gasketing
2.3.16.1 Extruded Aluminum Retainers
2.3.17 Soundproofing Gasketing
2.3.18 Rain Drips
2.3.18.1 Overhead Rain Drips
2.3.19 Auxiliary Hardware Other than locks
2.3.20 Special Tools
2.4 FASTENERS
2.5 FINISHES
PART 3 EXECUTION
3.1 INSTALLATION
3.1.1 Weatherstripping Installation
3.1.1.1 Stop Applied Weatherstripping
3.1.2 Soundproofing Installation
3.1.3 Threshold Installation
3.2 FIRE DOORS AND EXIT DOORS
3.3 HARDWARE LOCATIONS
3.4 FIELD QUALITY CONTROL
3.5 HARDWARE SETS
09 30 10
CERAMIC, AND QUARRY TILING
PART 1 GENERAL
1.1 REFERENCES
1.2 SUSTAINABILITY REPORTING
1.3 SUBMITTALS
1.4 QUALITY ASSURANCE
1.5 DELIVERY, STORAGE, AND HANDLING
1.6 ENVIRONMENTAL REQUIREMENTS
1.7 WARRANTY
1.8 EXTRA MATERIALS
PART 2 PRODUCTS
2.1 TILE
2.1.1 Mosaic Tile
2.1.2 Glazed Wall Tile
2.2 SETTING-BED
2.2.1 Aggregate for Concrete Fill
2.2.2 Portland Cement
2.2.3 Sand
2.2.4 Hydrated Lime
2.2.5 Metal Lath
2.2.6 Reinforcing Wire Fabric
2.3 WATER
2.4 MORTAR, GROUT, AND ADHESIVE
2.4.1 Dry-Set Portland Cement Mortar
2.4.2 Latex-Portland Cement Mortar
2.4.3 Ceramic Tile Grout
2.4.4 Organic Adhesive
2.4.5 Epoxy Resin Grout
2.4.6 Furan Resin Grout
2.4.7 Sealants
2.5 TRANSITION STRIPS
2.6 MEMBRANE MATERIALS
2.7 COLOR, TEXTURE, AND PATTERN
PART 3 EXECUTION
3.1 PREPARATORY WORK AND WORKMANSHIP
3.2 GENERAL INSTALLATION REQUIREMENTS
3.3 INSTALLATION OF WALL TILE
3.3.1 Dry-Set Mortar and Latex-Portland Cement Mortar
3.3.2 Organic Adhesive
3.3.3 Furan Mortar and Grout
3.3.4 Ceramic Tile Grout
3.4 INSTALLATION OF FLOOR TILE
3.4.1 Workable or Cured Mortar Bed
3.4.2 Dry-Set and Latex-Portland Cement
3.4.3 Ceramic Tile Grout
3.4.4 Waterproofing
3.4.5 Concrete Fill
3.5 INSTALLATION OF TRANSITION STRIPS
3.6 CLEANING AND PROTECTING
10 44 16
FIRE EXTINGUISHERS
PART 1 GENERAL
1.1 SUBMITTALS
1.2 DELIVERY, STORAGE, AND HANDLING
1.2.1 Samples
PART 2 PRODUCTS
2.1 SYSTEM DESCRIPTION
2.1.1 Accessories
2.2 EQUIPMENT
2.2.1 Wall Brackets
PART 3 EXECUTION
3.1 INSTALLATION
3.2 PROTECTION
3.2.1 Repairing
3.2.2 Cleaning
12 21 00
WINDOW BLINDS
PART 1 GENERAL
1.1 SUMMARY
1.2 REFERENCES
1.3 SUBMITTALS
1.4 SUSTAINABLE DESIGN CERTIFICATION
1.5 DELIVERY, STORAGE, AND HANDLING
1.6 WARRANTY
PART 2 PRODUCTS
2.1 WINDOW BLINDS
2.1.1 Horizontal Blinds
2.1.1.1 Head Channel and Slats
2.1.1.2 Controls
2.1.1.3 Intermediate Brackets
2.1.1.4 Bottom Rail
2.1.1.5 Braided Ladders
2.1.1.6 Hold-Down Brackets

2.2 COLOR

PART 3 EXECUTION
3.1 EXAMINATION
3.2 INSTALLATION
3.2.1 Horizontal and Audio Visual Blinds

3.3 CLEAN-UP

File details come from the government source that posted it.