Technical_Exhibit_7.5.2__Task_Codes.docx

DOCX document 56 KB Posted

Attached to
FORT GORDON BASE OPERATIONS AND MAINTENANCE SUPPORT SERVICES REQUEST FOR PROPOSAL - SOLICITATION Federal contract opportunity
Solicitation number
W91249-18-R-0001
Issued by
Department of the Army Materiel Command Mission and Installation Contracting Command Fort Gordon

About this file

Attachment 6 - TE 7.5.2 - Task Codes

View the file

Other files for this federal contract opportunity

Other files attached to FORT GORDON BASE OPERATIONS AND MAINTENANCE SUPPORT SERVICES REQUEST FOR PROPOSAL - SOLICITATION, newest first.
File Type Posted
W91249-18-R-0001-0004.docx DOCX document
Attachment_16_-_Revised_Questions_&_Responses_to_Solicitation_&_Amendment_0001_0002__and_0003.pdf PDF
Technical_Exhibit_7.5.9.8.1__Dumpster_Locations_List.docx DOCX document
W91249-18-R-0001-0003.pdf PDF
Attachment_16_-_Revised_Questions_&_Responses_to_Solicitation_&_Amendment_0001.pdf PDF
Attachment_10_-_Pricing_and_Labor_Matrix_Worksheet_(Revision_1).xlsx XLSX spreadsheet
Attachment_16_-_Questions_&_Responses_to_Solicitation_&_Amendment_0001.pdf PDF
Technical_Exhibit_7.3.3__PWO_Workload.docx DOCX document
Amendment_W91249-18-R-0001-0001.pdf PDF
Attachment_10_-_Pricing_and_Labor_Matrix_Worksheet.xlsx XLSX spreadsheet
Technical_Exhibit_7.5.6.6_Range_Hood_Cleaning_Services.docx DOCX document
Technical_Exhibit_7.5.7.5_Range_Mowing_Map.docx DOCX document
Technical_Exhibit_7.5.9.2__Central_Energy_Plant_No._1_Building_25910_Buildings_Served.docx DOCX document
Technical_Exhibit_7.5.7.7_Flower_Beds.doc DOC document
Attachment_11_-_Sample_Past_Performance_Cover_Letter.docx DOCX document
Technical_Exhibit_7.5.4.3_Underground_Storage_Tanks.docx DOCX document
Technical_Exhibit_7.4.5__Government_Furnished_Vehicles.docx DOCX document
Technical_Exhibit_7.4.3__Fort_Gordon_Facility_Listing_(Excluding_Privatized_Facilities).docx DOCX document
Technical_Exhibit_7.5.8.5_Lakes_and_Ponds.docx DOCX document
Technical_Exhibit_7.5.6.2_Electrical_Lines_of_Demarcation.doc DOC document
Attachment_8_-_Service_Contract_Act_(SCA)_Wage_Determation_2015-4465_Rev5.pdf PDF
Technical_Exhibit_7.5.9.8_Dumpster_Container_Cleaning_List.docx DOCX document
Technical_Exhibit_7.5.6.3__Natural_Gas_Lines_of_Demarcation.doc DOC document
Technical_Exhibit_7.5.9.3a__Plant_No._1_Operation_CEP_CHW_and_High_Temperature_Water_(HTW).doc DOC document
Technical_Exhibit_7.4.7_Energy_Conservation_Measures.docx DOCX document
W91249-18-R-0001.pdf PDF
Technical_Exhibit_7.4.1__Contractor_Personnel_Minimum_Qualifications.docx DOCX document
Technical_Exhibit_7.5.7.6_Semi-Improved_Grounds_Maintenance_Areas_Frequency_Schedule.docx DOCX document
Technical_Exhibit_7.5.6.20_Pest_Control_Services_Look_Ahead_Report_Template.doc DOC document
Technical_Exhibit_7.3.3__PWO_Workload.docx DOCX document
Technical_Exhibit_7.5.9.1__Central_Energy_Plant_No__1_Bldg_25910_Installed_Equipment.docx DOCX document
Technical_Exhibit_7.3.1__DMO_Workload.docx DOCX document
Technical_Exhibit_7.5.7.8_Fort_Gordon_Cemeteries.doc DOC document
Technical_Exhibit_7.5.9.7_Fuel_Oil_Tanks_At_Dual_Fired_Facilities.doc DOC document
Technical_Exhibit_7.5.6.12_Emergency_Generators.docx DOCX document
Technical_Exhibit_7.3.4__RPMA_Supply_Operations_Estimated_Workload.docx DOCX document
Technical_Exhibit_7.5.6.7_Lifts_and_Cranes_Inventory.docx DOCX document
Technical_Exhibit_7.3.2__OWO_Workload.docx DOCX document
Technical_Exhibit_7.3.7_Estimated_Furniture_Management_Workload.docx DOCX document
Technical_Exhibit_7.5.4.2_Water_Monitoring_Wells_Requiring_Sampling_and_Analysis.docx DOCX document
Technical_Exhibit_7.5.7.1_Ft._Gordon_Grounds_Mowing_Map.docx DOCX document
Attachments_4_-_6_-_DRAFT_Technical_Exhibits_7.3_7.4_7.5.docx DOCX document
Technical_Exhibit_7.5.6.18_Public_Works_Look_Ahead_Report_Template.doc DOC document
Attachment_10_-_Pricing_and_Labor_Matrix_Worksheet.xlsx XLSX spreadsheet
Technical_Exhibit_7.5.7.9_Pruning_Standards.docx DOCX document
Technical_Exhibit_7.5.8.1_Recreation_and_Athletic_Fields.docx DOCX document
Technical_Exhibit_7.5.8.4_Special_Events_Taskings.doc DOC document
Technical_Exhibit_7.5.5.1._Pest_Control_Amplifying_Information.docx DOCX document
Technical_Exhibit_7.4.2_Government_Furnsihed_Equipment.docx DOCX document
Technical_Exhibit_7.5.7.7.1_Estimated_IDIQ_Qunatities.docx DOCX document
Show all 50

FORT GORDON BASE OPERATIONS AND MAINTENANCE SUPPORT SERVICES REQUEST FOR PROPOSAL - SOLICITATION has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Technical Exhibit 7.5.2 Task Codes

TASK
TASK DESCRIPTION
Priority Assigned to Installation Facilities
Priority Assigned to Child Development Centers/Children Youth Service Support Centers,
Priority Assigned to Barracks Facilities
PRIORITY EXCEPTION
1
LOCKS/KEYS
2
1
2
001A
RE-KEY ROOM
001B
RE-CORE ROOM
001C
KNOB
001D
SAFES
001E
OCCUPANT LOCKED OUT

1 - Lockout/Security

001F
RE-KEY FACILITY
001G
RE-KEY EQUIPMENT
001H
RE-CORE FACILITY
001I
LOCKS/INOP

1 - Lockout/Security

001J
REPRODUCE KEYS
2
EXTERIOR(Carpentry/Sheet metal/ Masonry)
3
1
3
002A
SIDING

1 - Safety Issue

002B
AWNING

1 - Safety Issue

002C
DOWNSPOUTS

1 - Safety Issue

002D
PRESSURE WASH
002E
BRICKWORK
002F
CONCRETE
002G
CAULK WINDOWS
002H
INSTALL FRENCH DRAIN

Considered “L” Work

002I
HARDWARE
002J
PAINT
002K
WINDOW HARDWARE

1 - SECURITY ISSUE

002L
WINDOW GLASS

1 - SECURITY ISSUE

002M
DOOR GLASS

1 - SECURITY ISSUE

002N
SCREENS
002Q
TREADS

1 - Safety Issue

002R
HANDRAILS

1 - Safety Issue

3
INTERIOR(Carpentry/Sheet-metal /Masonry)
3
1
3
003A
FIREWALL PENETRATION

1 - Safety Issue

003B
PAINTING
003C
PATCHING
003D
WALL COVERING
003E
BASEBOARD
003F
TRIM
003G
DOORS

1 – Security Issue

003H
WINDOWS

1 – Security Issue

003I
FRAMES
003J
DOOR STOPPER/CLOSER

1 – Security Issue

003K
WINDOW HARDWARE

1 – Security Issue

003L
WOODWORK
003M
SHELVING
003N
AUTO DOOR CLOSER
003O
HARDWARE
003P
CEILING TILE
003Q
PARTITIONS
003R
MOUNTING ACCS.
003S
FLOORING

1 - Safety Issue

003T
TREADS

1 - Safety Issue

003U
HANDRAILS
2
1 - Safety Issue
003V
GENDER ALARMS
2
1 - Security Issue
6
ROOF
2
1
2
006A
CLEAN ROOF DRAINS
006B
GUTTERS
006C
DOWNSPOUTS
006D
ROOF VENT
006E
VENTILATION
006F
SEAL JOINT
006G
REPLACE SHINGLE
006H
RE-COAT
006I
INSPECTION
006J
LEAKS
006K
FLASHING
7
PLUMBING
2
1
2
007A
FAUCET LEAK
007B
UNSTOP DRAINS

1 - Safety/Health Issue

007C
PIPING LEAK

1 - Safety Issue

007D
URINAL
007E
SHOWERHEAD
007F
REPLACE FAUCET
007G
FLUSH VALVE

1 - Only toilet in room

007H
TANK BOLTS
007I
REPLACE WASHER
007J
WAX SEAL
007K
REPLACE TRAPS
007L
FIXTURE
17
ELECTRICAL
2
1
2
017A
COMPLETE OUTAGE

1 - Complete Outage/Installation /EAMC

017B
FEEDER OUTAGE

1 - Complete Outage/Installation /EAMC

017C
BUILDING OUTAGE

1 - Complete Outage/Installation /EAMC

017D
CIRCUIT OUTAGE

1 - Mission Impacting

017E
COMPONENT OUTAGE

1 - Mission Impacting

017F
CIRCUIT
017G
CONDUIT
017H
PANEL
017I
INTERIOR LIGHTS
017J
MAIN DISTRIBUTION PANEL

1 - Mission Impacting

017K
BRANCH DISTRIBUTION PANEL

1 - Mission Impacting

017L
CIRCUIT BREAKER
017M
TRANSFORMER

1 - Complete Outage/Installation/ EAMC

017N
REPLACE FUSES
017O
EXIT LIGHTS
017P
LIGHTNING PROTECTION

1 - Safety Issue

017Q
PHOTO CELL
017R
TIMER
017S
REPLACE BALLAST
017T
EMERENCY GENERATOR

1 - Mission Impacting

017U
TRANSFER GEAR

1 - Mission Impacting

017V
CONNECT
017W
DISCONNECT
017X
METER
017Y
EMERGENCY LIGHTS

1 - Mission Impacting

017Z
FLUORESCENT LIGHT
17AA
RECEPTACLE
17BB
SWITCH
17CC
NAVIGATIONAL LIGHTS

1 - Safety Issue

17DD
PARTIAL OUTAGE
17EE
FIXTURES
17FF
OVERHEAD LINES
17GG
UNDERGROUND LINES
17HH
DE-ENERGIZE
17II
ENERGIZE
17JJ
EXTERIOR LIGHTS
17KK
ICIDS
2
2
2
Component Assessment
21
FIRE PROTECTION
1
1
1
021A
HYDRANTS
021B
DETECTORS
021C
CONTROL PANEL
021D
ALARMS
021E
TRANSMITTER
021F
SUPPRESSION
021G
PULL STATIONS
021H
STROBE
021I
SPRINKLER HEADS
021J
FIRE DAMPERS
021K
EXTINGUISHER
22
IN-PLACE EQUIPMENT
3
1
3
022A
HAND DRYER
022B
EYE-WASH STATION

1 - Safety Issue

022C
LOCKER( Built In)
022D
RESERVED
022E
PLAYGROUND EQUIPMENT
2

1 – SAFETY ISSSUE

26
EXTERIOR WATER
2
1
2
1 – CDC/CYSS
026A
COMPLETE OUTAGE

1 - Installation//EAMC

026B
DISTRIBUTION OUTAGE

1 – Installation/EAMC

026C
BUILDING OUTAGE

1 - Installation/EAMC

026D
HYDRANT
N/A
N/A
N/A
026E
LOW WATER PRESSURE
026F
CONNECT
026G
DISCONNECT
026H
CHLORINE

1 - Health Issue

026I
METER
026J
PIPE LEAK

1 for Dining facility

026K
BACKFLOW
1
1
1
026L
FLUSHING
026M
MANHOLE PUMPOUT
2
27
WASTEWATER
1
1
1
027A
LIFT STATION
027B
PUMPS
027C
CONNECT
027D
DISCONNECT
027E
SEWER CLEANOUT
027F
LOCATE
027G
PUMP SEPTIC TANK
28
LP/NATURAL GAS
2
1
2
028A
LEAK

1 - Installation//EAMC

028B
BURNING ODOR

1 - Installation/EAMC

028C
LP GAS TANK

1 - Installation//EAMC

028D
LP GAS PIPING

1 - Installation/EAMC

028E
CONNECT
028F
DISCONECT
028G
SAFETY VALVE

1 - Installation/EAMC

028H
METER
028I
REGULATOR

1 - Installation/EAMC

028J
PURGE
028K
REMOVE TANK
31
DFAC EQUIPMENT
1
1
N/A
031A
REFRIGERATION (COOLERS/FREEZERS)

Real Property, built-in to facility, not ON to the facility

031B
FAT FRYERS

Personal Property / Reimbursable

031C
RANGERS

Personal Property / Reimbursable

031D
OVENS

Personal Property / Reimbursable

031E
COFFEE UM

Personal Property / Reimbursable

031F
TRASH COMPACTORS

Personal Property / Reimbursable

031G
DISPOSALS

Personal Property / Reimbursable

031H
DISHWASHER

Personal Property / Reimbursable

031I
GRILLS

Personal Property / Reimbursable

031J
STREAM KETTLES

Personal Property / Reimbursable

031K
REACH-IN

Personal Property / Reimbursable

031L
WALK-IN

Real Property, built-in to facility, not ON to the facility

031M
PRESSURE COOKERS

Personal Property / Reimbursable

031N
AIR CURTAINS

Personal Property / Reimbursable

031O
SALAD BAR

Personal Property / Reimbursable

031P
SERVING LINE

Personal Property / Reimbursable

031Q
INSTALL EQUIP

Real Property, built-in to facility, not ON to the facility

031R
ICE MACHINES
2
2
N/A
Personal Property / Reimbursable
031S
Equipment Gasket/Seals
2
2
N/A
Personal Property / Reimbursable
36
AIR CONDITIONING
2
1
2
036A
WINDOW UNIT

1 - Real Property - Any area in facility to include entire facility without AC Personal Property/Reimbursable

036B
CHILLER

1 - Any area in facility to include entire facility without AC

036C
COMPRESSOR

1 - Any area in facility to include entire facility without AC

036D
AIR HANDLER

1 - Any area in facility to include entire facility without AC

036E
INTEGRAL CONTROLS

1 - Any area in facility to include entire facility without AC

036F
DISTRIBUTION PIPING

1 - Any area in facility to include entire facility without AC

036G
VAV BOX

1 - Any area in facility to include entire facility without AC

036H
PUMP

1 - Any area in facility to include entire facility without AC

036I
VALVE

1 - Any area in facility to include entire facility without AC

036J
PIPING

1 - Any area in facility to include entire facility without AC

036K
AIR COMPRESSOR

1 - Any area in facility to include entire facility without AC

036L
THERMOSTAT

1 - Any area in facility to include entire facility without AC

036M
RELIEF VALVE

1 - Any area in facility to include entire facility without AC

036N
PRESSURE GAGE

1 - Any area in facility to include entire facility without AC

036O
DUCKWORK

1 - Any area in facility to include entire facility without AC

036P
VALVE BOX

1 - Any area in facility to include entire facility without AC

036Q
GASKET/SEALS

1 - Any area in facility to include entire facility without AC

036R
PULLEY/BELTS

1 - Any area in facility to include entire facility without AC

036S
FANS

1 - Any area in facility to include entire facility without AC

036T
MOTORS

1 - Any area in facility to include entire facility without AC

036U
CLEAN/CLEAR COIL

1 - Any area in facility to include entire facility without AC

036V
BEARINGS

1 - Any area in facility to include entire facility without AC

036W
CONVERTER

1 - Any area in facility to include entire facility without AC

036X
FAN COIL UNIT

1 - Any area in facility to include entire facility without AC

036Y
CONDENSATE DRAIN

1 - Any area in facility to include entire facility without AC

036Z
COOLING TOWER

1 - Any area in facility to include entire facility without AC

36AA
COOLING TOWER PUMP

1 - Any area in facility to include entire facility without AC

36BB
COOLING TOWER FAN

1 - Any area in facility to include entire facility without AC

36CC
EVAPORATOR COIL

1 - Any area in facility to include entire facility without AC

36DD
CHARGE REFRIGERANT

1 - Any area in facility to include entire faclity without AC

36EE
REFRIGERANT LEAK

1 - Any area in facility to include entire facility without AC

36FF
ECONOMIZER

1 - Any area in facility to include entire facility without AC

36GG
RESET CHILLER

1 - Any area in facility to include entire facility without AC

36HH
CONTROL VALVE

1 - Any area in facility to include entire facility without AC

36II
DRAIN SYSTEM

1 - Any area in facility to include entire facility without AC

36JJ
INSULATION

1 - Any area in facility to include entire facility without AC

36KK
VENTS
3
36LL
FREON RECOVERY
37
HEATING
2
1
2
037A
BOILER

1 - Any area in facility to include entire facility without heat

037B
HIGH-TEMP PIPINIG

1 - Any area in facility to include entire facility without heat

037C
INTEGRAL CONTROLS

1 - Any area in facility to include entire facility without heat

37D
AIR HANDLER

1 - Any area in facility to include entire facility without heat

037E
VAV BOX

1 - Any area in facility to include entire facility without heat

037F
PUMP

1 - Any area in facility to include entire facility without heat

037G
VALVE

1 - Any area in facility to include entire facility without heat

037H
PIPING

1 - Any area in facility to include entire facility without heat

037I
COMPRESSOR

1 - Any area in facility to include entire facility without heat

037J
WINTERIZE BUILDING
037K
FUEL PUMP

1 - Any area in facility to include entire facility without heat

037L
AIR COMPRESSOR

1 - Any area in facility to include entire facility without heat

037M
FIRE STAT

1 - Any area in facility to include entire facility without heat

037N
THERMOSTAT

1 - Any area in facility to include entire facility without heat

037O
RELIEF VALVE

1 - Any area in facility to include entire facility without heat

037P
PRESSURE GAGE

1 - Any area in facility to include entire facility without heat

037Q
DUCTWORK

1 - Any area in facility to include entire facility without heat

037R
VALVE BOX

1 - Any area in facility to include entire facility without heat

037S
GASKETS/SEALS

1 - Any area in facility to include entire facility without heat

037T
PULLEY/BELTS

1 - Any area in facility to include entire facility without heat

037U
FANS

1 - Any area in facility to include entire facility without heat

037V
MOTORS

1 - Any area in facility to include entire facility without heat

037W
CLEAN/CLEAR COIL

1 - Any area in facility to include entire facility without heat

037X
BEARINGS

1 - Any area in facility to include entire facility without heat

037Y
CONVERTER

1 - Any area in facility to include entire facility without heat

037Z
FAN COIL UNIT

1 - Any area in facility to include entire facility without heat

37AA
UNIT HEATER

1 - Any area in facility to include entire facility without heat

37BB
RADIANT HEATER

1 - Any area in facility to include entire facility without heat

37CC
RESET BOILER

1 - Any area in facility to include entire facility without heat

37DD
IGNITOR

1 - Any area in facility to include entire facility without heat

37EE
CONTROL VALVE

1 - Any area in facility to include entire facility without heat

37FF
FUEL TANK

1 - Any area in facility to include entire facility without heat

37GG
DRAIN SYSTEM

1 - Any area in facility to include entire facility without heat

37HH
INSULATION
37II
FUEL DELIVERY

1 - Any area in facility to include entire facility without heat

39
APPLIANCE EQUIPMENT
2
1
2
039A
WASHERS

UPH Equipment

039B
DRYERS

UPH Equipment

039C
DRYER VENT

UPH Equipment

039D
WASHER HOSE

UPH Equipment

039E
LINT TRAP

UPH Equipment

039F
HEATING ELEMENT

UPH Equipment

039G
GASKET

UPH Equipment

039H
TIMER

UPH Equipment

039I
INSTALL

UPH Equipment

039J
KNOB

UPH Equipment

039K
PUMP

UPH Equipment

039L
MOTOR

UPH Equipment

039M
BELT

UPH Equipment

039N
ROLLERS

UPH Equipment

039O
DRUM

UPH Equipment

039P
RESERVED
039Q
REFRIGERATORS (UPH)
2
Component Assessment
039R
WASHER VANDALISM

UPH Equipment

039S
DRYER VANDALISM

UPH Equipment

42
SIGNS
3
1
3
042A
BUILDING
042B
TRAFFIC
2
042C
HANG WOOD SIGN
042D
REPAIR WOOD SIGN
042E
STRAIGHTEN SIGN POST
042F
REPLACE SIGN
042G
RELETTER
042H
INSTALL
042I
RELOCATE
042J
FABRICATE
042K
REPLACE SIGN POST
042L
REPAIR SIGN
53
TRAFFIC LIGHTS
1
N/A
N/A
053A
FIXTURES
053B
INSPECTION
54
DIG SURVEY
2
2
2
1-Emergency Dig
054A
ELECTRICAL
054B
GAS
054C
HIGH TEMP
054D
CHILLED WATER
054E
WATER
054F
SEWAGE
054G
STORMWATER DRAINS
60
GROUNDS MAINTENANCE
3
1
3
060A
WEED CONTROL
060B
BIRD CONTROL
060C
REMOVE DEAD ANIMALS
060D
TRAP ANIMALS
060E
CLEAN & HAUL DEBRIS
060F
GRADE RUNNING TRACK
060G
EXCAVATE SOIL
060H
SODDING
060I
HYDROSEEDING
060J
CUT/REMOVE TREE
060K
REMOVE SHRUB
060L
GRADING
060M
EROSION
060N
GRASS CUTTING
060O
EDGING
06OP
FORKLIFT/EQUIPMENT SUPPORT
61
GROUNDS MATERIAL DELIVERY
3
1
3
061A
SAND
061B
MULCH
061C
GRAVEL
061D
ASPHALT
061E
RIP-RAP
061F
TOP SOIL
64
FENCES/GATES REPAIRS
3
1
2
1 - Security Issue
064A
FENCE
064B
GATE
064C
POST
67
SPRAY INSIDE
2
1
2
067A
ANTS
067B
BEES
067C
FLIES
067D
MOSQUITOS
067E
TERMITES
067F
WASPS
067G
ROACHES
68
SPRAY OUTSIDE
2
1
2
068A
ANTS
068B
BEES
068C
FLIES
068D
MOSQUITOS
068E
TERMITES
068F
WASPS
068G
ROACHES
068H
HERBICIDE
70
DOMESTIC WATER
2
1
2
070A
WATER FOUNTAIN
070B
WATER HEATER

1 - Entire Facility

070C
STORAGE TANK
070D
PIPING
070E
BURNERS
070F
HOT WATER - BLDG

1 - Entire Facility

070G
HOT WATER - ROOM
070H
CIRC. PUMP

1 - Entire Facility

78
MASTER CLOCK SYSTEM
2
N/A
N/A
Component Assessment
82
ELEVATORS
2

1 All light Out

082A
LIGHTS
082B
FANS
83
INTRUSION DETECTION
1
1
1
083A
ICIDS
1
93
LEAD SAMPLE
2
1
2
093A
SAMPLE
093B
SURVEY
093C
REMOVE/ABATE
95
ASBESTOS
2
1
2
095A
SAMPLE
095B
SURVEY
095C
REMOVE/ABATE
96
HAZ-MAT
2
1
2
096A
MOLD
096B
BIOHAZARD CLEANUP
1
1
1
096C
OIL SPILLS
1
1
096D
UNKNOWN SAMPLE
97
INBETWEEN OCCUPANCY MAINT
N/A
N/A
3
N/A
097A
CARPENTRY
097B
ELECTRICAL
097C
PLUMBING
097D
HVAC
097E
LOCKS