Amendment_0004_-_Updated_Drawing_M-601.pdf
PDF 1 MB Posted
- Attached to
- FY16 Poe Lock Electrical Modernization
- Solicitation number
- W911XK-16-R-0005
About this file
Amendment 0004 - Updated Drawing M-601
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M-601
J L
O W
E
E L E
IS
U R
E A F
R E
G O
S O
S C
H E
D U
L E
S D
IA
G R
A M
S S
U M
P P
U M
P H
V A
C
S L P
L
M -6
.d g n
A N
S I
D
M A
Y
/s J
O H
N E
N
IT
E S P .E
W
X K -1
-R -0
EF-9 & EF-19 SHALL NOT OPERATE UNTIL INTAKE AND EXHAUST LOUVERS ARE OPEN.2.
THE OPERATION OF THE FANS WILL BE CONTROLLED BY A PLC FROM THE CONTROL ROOM.1.
NOTES:
CONTROL INPUT FROM CONTROLLER. ACTUATOR SHALL HAVE A 2 TO 10 VDC FEED BACK SIGNAL FOR POSITION INDICATION.
ACTUATOR MOTORS SHALL OPERATE ON 24VDC POWER SOURCE. ACTUATOR SHALL OPERATE ON A 4 TO 20 mA
LOUVER ACTUATORS SHALL BE PROVIDED WITH AUXILIARY CONTACTS FOR INDICATION OF OPEN & CLOSE POSITIONS.3.
PROVIDE L-1 WITH EXTERIOR INSECT SCREEN.2.
PROVIDE ELECTRIC MOTOR ACTUATOR FOR L-1 THRU L-3. COORDINATE OPERATION OF LOUVERS WITH EF-9 AND EF-19.1.
NOTES:
SCHEDULE (UH) HEATERUNIT
MARK
REQ'D
TOTAL
TYPE
UNIT
SPHASE/AMP
VOLTAGE/
SOURCE
VOLTAGE
SERVICE
Kw.
CAP.
CFM
CAPACITY
FAN
REMARKS
UH-1 1 ELECTRIC 480/3/6.0 DPB-1P ROOM PUMP SOCKET 11FENDER 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-2 1 ELECTRIC 480/3/6.0 DPB-1P ROOM PUMP 1NGATE 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-3 1 ELECTRIC 480/3/6.0 DPB-1P 1 ROOMSWITCHBOARD 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-4 1 ELECTRIC 480/3/6.0 DPB-1P 1 ROOMSWITCHBOARD 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-6 1 ELECTRIC 480/3/6.0 DPB-1P ROOM PUMP SOCKET 12FENDER 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-7 1 ELECTRIC 480/3/6.0 DPB-1P ROOM PUMP 1NVALVE 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-8 1 ELECTRIC 480/3/6.0 DPB-2P ROOM PUMP SOCKET 13FENDER 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-9 1 ELECTRIC 480/3/6.0 DPB-2P ROOM PUMP 2NVALVE 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-10 1 ELECTRIC 480/3/6.0 DPB-2P ROOM PUMP 2NGATE 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-11 1 ELECTRIC 480/3/6.0 DPB-2P 2 ROOMSWITCHBOARD 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-12 1 ELECTRIC 480/3/6.0 DPB-2P 2 ROOMSWITCHBOARD 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-14 1 ELECTRIC 480/3/6.0 DPB-2P ROOM PUMP 3NGATE 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-15 1 ELECTRIC 480/3/6.0 DPB-2P ROOM PUMP SOCKET 14FENDER 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-16 1 ELECTRIC 480/3/6.0 DPB-3P ROOM PUMP BOOM 11FENDER 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-17 1 ELECTRIC 480/3/6.0 DPB-3P ROOM PUMP 1SGATE 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-18 1 ELECTRIC 480/3/6.0 DPB-3P ROOM PUMP BOOM 12FENDER 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-19 1 ELECTRIC 480/3/6.0 DPB-3P ROOM PUMP 1SVALVE 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-20 1 ELECTRIC 480/3/6.0 DPB-4P ROOM PUMP BOOM 13FENDER 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-21 1 ELECTRIC 480/3/6.0 DPB-4P ROOM PUMP 2SVALVE 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-22 1 ELECTRIC 480/3/6.0 DPB-4P ROOM PUMP 2SGATE 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-23 1 ELECTRIC 480/3/6.0 DPB-4P ROOM PUMP 3SGATE 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
UH-24 1 ELECTRIC 480/3/6.0 DPB-4P ROOM PUMP BOOM 14FENDER 5 350 THERMOSTAT INTEGRAL AND FAN WITH MOUNTWALL
SCHEDULE (EF) FANEXHAUST
MARK
REQ'D
TOTAL
TYPE
FAN
PHASE
VOLTAGE/
SOURCE
VOLTAGE
SERVICE TYPE CFM
WATER
INESP
REMARKS
4 3, 2,EF-1, 4 EXHAUST 120/1 DPB-1A ROOMSPUMP PROPELLER 231 0.10
REQUIRED AS BOX JUNCTION OR RECEPTACLE NEW MATCHTO
LENGTH SUFFICIENT OF PLUG AND PIGTAIL ELECTRICALPROVIDE
8 7, 6,EF-5, 4 EXHAUST 120/1 DPB-2A ROOMSPUMP PROPELLER 231 0.10
REQUIRED AS BOX JUNCTION OR RECEPTACLE NEW MATCHTO
LENGTH SUFFICIENT OF PLUG AND PIGTAIL ELECTRICALPROVIDE
EF-9 1 EXHAUST 480/3 CC2 GALLERY PROPELLER 4500 0.20 POSITION OPEN LOUVER WITH OPERATION FANINTERLOCK
EF-10 1 EXHAUST 120/1 DPB-2A ROOMSPUMP PROPELLER 231 0.10
REQUIRED AS BOX JUNCTION OR RECEPTACLE NEW MATCHTO
LENGTH SUFFICIENT OF PLUG AND PIGTAIL ELECTRICALPROVIDE
14 13, 12,EF-11, 4 EXHAUST 120/1 DPB-3A ROOMSPUMP PROPELLER 231 0.10
REQUIRED AS BOX JUNCTION OR RECEPTACLE NEW MATCHTO
LENGTH SUFFICIENT OF PLUG AND PIGTAIL ELECTRICALPROVIDE
18 17, 16,EF-15, 4 EXHAUST 120/1 DPB-4A ROOMSPUMP PROPELLER 231 0.10
REQUIRED AS BOX JUNCTION OR RECEPTACLE NEW MATCHTO
LENGTH SUFFICIENT OF PLUG AND PIGTAIL ELECTRICALPROVIDE
EF-19 1 EXHAUST 480/3 CC2 GALLERY PROPELLER 4500 0.20 POSITION OPEN LOUVER WITH OPERATION FANINTERLOCK
EF-20 1 EXHAUST 120/1 DPB-4A ROOMSPUMP PROPELLER 231 0.10
REQUIRED AS BOX JUNCTION OR RECEPTACLE NEW MATCHTO
LENGTH SUFFICIENT OF PLUG AND PIGTAIL ELECTRICALPROVIDE
SCHEDULE (P)PUMP
MARK
PHASE
VOLTAGE/
SOURCE
VOLTAGE
SERVICE REMARKS
P-1 480/3 CC1 SOCKET 11 RECESS CYLINDERBRAKE
INSTALLEDBE
TO EQUIPMENT FURNISHEDGOVERNMENT
P-3 480/3 CC2 GALLERY CROSSOVERD/S RE-INSTALLED BE TO PUMPEXISTING
P-4 480/3 CC2 GALLERY CROSSOVERD/S RE-INSTALLED BE TO PUMPEXISTING
P-6 480/3 CC1 BOOM 11 RECESS CYLINDERBRAKE
INSTALLEDBE
TO EQUIPMENT FURNISHEDGOVERNMENT
P-7 480/3 CC1 GALLERY CROSSOVERU/S RE-INSTALLED BE TO PUMPEXISTING
P-8 480/3 CC1 GALLERY CROSSOVERU/S RE-INSTALLED BE TO PUMPEXISTING
(L)SCHEDULELOUVER
MARK
REQ'D
TOTAL
TYPE
UNIT
CFM
DESIGN
W.C.)(IN
ESP
SERVICE REMARKS
L-1 8 OPERABLE 4500 0.125 S-3) & (N-3 STRUCTURE INTAKEAIR MOTORIZED
L-2 1 OPERABLE 4500 6.0
S-56) & (N-56 DUCTDISCHARGE
GALLERYCABLE MOTORIZED
L-3 1 OPERABLE 4500 6.0 MOTORIZED
DIAGRAM ALARM AND CONTROL PUMPSUMP
NUMBER
DESIGNATION
PUMP
FUNCTION
PUMP
CHANGE
LEVEL
WATEROF
DIRECTION
LEVELWATER
BOTTOM
ABOVE
6"
-OFF
SUMP
MIDWAY
ON
FLOOR
WBELO
8"
FLOOR
WBELO
4"
ALARM
HIGH
FLOOR
WBELO
2"
ALARM
HIGH
HIGH
&P-7P-3
1STSTART RISING
1STSTOP FALLING
P-8 &P-4
2NDSTART RISING
2NDSTOP FALLING
P-6P-1, PUMPSTART RISING
PUMPSTOP FALLING
PUMPSALL ALARM RISING
P-8&
P-7, P-4,P-3, ALARM RISING
A_03L1A
D_03L1A
A_03L1B
D_03L1B
A_03L1C
D_03L1C
A_03L1D
D_03L1D
A_56L3A
D_56L3A
(CPS56)
CPN56
PANEL
CONTROL
EXISTING
(S-56)
N-56
LOUVER
EXHAUST
SOUTH GALLERY - S-03
NORTH GALLERY - N-03
INTAKE LOUVER ONE-LINE DIAGRAM
SOUTH GALLERY - S-56
NORTH GALLERY - N-56
EXHAUST LOUVER ONE-LINE DIAGRAM
(S-03)
N-03
LOUVER 1A
INTAKE
(S-03)
N-03
LOUVER 1B
INTAKE
(S-03)
N-03
LOUVER 1C
INTAKE
(S-03)
N-03
LOUVER 1D
INTAKE
(CPS03)
CPN03
PANEL
CONTROL
EXISTING
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
S
A AF
E
Y
Y
T
P S
C O
R P
S
O F
E N
G
IN
E E
R S
D E
T R
O
IT
D
IS
T R
IC
T
In c r e a s e
P r o f it .S u b m it
V
E C
P 'S
V a lu e n g in e e r in g
D
T R
O
IT
M
IC
H
IG
A N
D E
T R
O
IT
D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
Detroit District of Engineers
US Army Corps
SHEET OF
IDENTIFICATION
SHEET
P O
E L
O C
K E
L E
C T
R
IC
A L M
O D
E R
N
IZ
A T
IO
N S
O O L
O C
K C
O M
P L E
X S
A U
L T S
T E
M A
R
IE
M I
CERTIFIED FINAL DOCUMENTS
H7ET9JTI
Line
H7ET9JTI
Callout
H7CT9BMW
Text Box Drawing Revision for Solicitation Amendment 0004
File details come from the government source that posted it. Updated .