Attach_0003_TIQ14Aug2017.docx

DOCX document 18 KB Posted

Attached to
GENERAL MECHANICS TOOL KIT
Solicitation number
w56hzv16r0092
Issued by

About this file

Technical Information Questionnaire

View the file

Other files

File Type Posted
W56hzv16R0092_SOL_Amendment_0005.pdf PDF
Attach_0001_-_GMTK_component_list_Rev4.xlsx XLSX spreadsheet
W56hzv16R0092_SOL_Amendment_0004.pdf PDF
Attach_0003_TIQ14NOV2017.docx DOCX document
Questions_and_Answers_for_the_GMTK_0002.pdf PDF
Attachment_0001_-_GMTK_component_list_Rev3.xlsx XLSX spreadsheet
W56HZV16R0092-0003.pdf PDF
Attach_0005_-_Replacement_Spreadsheet.xlsx XLSX spreadsheet
Attach_0006_Product_Engineering_Requirements_(003).docx DOCX document
Attach_0002_-_PES_Oct_2017.xlsx XLSX spreadsheet
W56HZV16R0092-0002.pdf PDF
Attach_0001_-_GMTK_component_list_Rev3.xlsx XLSX spreadsheet
Attach_0004_-Technical_Factor_Elements-DELETED.xlsx XLSX spreadsheet
W56hzv16R0092_SOL_Amendment_0001B.pdf PDF
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GMTK Took Chest – Technical Information Questionnaire (TIQ)

Company:________________________________ Cage Code:_______________________ POC: ____________________________________ POC Telephone:___________________ POC Email:_______________________________

The following TIQ is intended to support the Government’s determination whether the proposed GMTK Tool Chest is technically acceptable and is capable of meeting the performance requirements outlined in the Solicitation and attached drawings. The proposer’s failure to answer each of the questions in this TIQ and submit substantiating data may result in the rejection of the proposal. Every question must be supported with substantiating data as detailed in RFP Section L.3.2 and below. The product offered must meet ALL of the capabilities and requirements as described in the Item Description and specification (attachment 0001) for the GMTK Took Chest. Please answer every question below indicating via an “X” in the “Yes” or “No” column. Substantiating data shall also be attached to this completed TIQ. The substantiating data for questions shall be in the form listed in the column titled “Verification”.

Vendor Response

Item #
Evaluation Question
Reference: Description
Verification
Yes
No
Proposal Location of Substantiating Data
1
Are the tool chest drawers fully extendable so that all portions of the drawer are accessible with each tool able to be lifted straight up out of any drawer without interference with the tool chest or other drawers no matter where it is located in the drawer?
Drawing 0627B0000, note 3.4.6
Provide written response and drawings/figures of one drawer highlighting accessible space claim for proposed tool placement, taking into consideration tool chest overlap.
2
Does the tool chest have an adequate number or size of side handles for a 4-person lift?
Drawing 0627B0000, note 3.5.1
Provide drawings/figures to depict proposed handle locations and manufacturer’s specification sheet for proposed handles.
3
Are the tool chests stackable and crush resistant when loaded with no less than 3 other identical tool chests, each loaded to 120 pounds, stacked on top of it?
Drawing 0627B0000, notes 3.8.2 and 3.8.3
Provide test report for proposed or similar tool chest.
4
Is the tool chest rated for use in temperatures from -25°F to +170°F?
Drawing 0627B0000, notes 3.8.6 and 3.8.10
Provide test reports, commercial item literature, user manuals, or material specification sheets for the proposed or similar tool chest.
5
Is the tool chest resistant to water entry when immersed in water to a depth of no less than 1 meter (3.28 feet) for no less than 30 minutes?
Drawing 0627B0000, note 3.8.7
Provide test report for proposed tool chest.
6
Is the tool chest equipped with a pressure relief valve that regulates air with changing altitude and temperature to equalize pressures while prohibiting the intrusion of water and dust?
Drawing 0627B0000, note 3.8.12
Provide manufacturer’s specification sheet for proposed relief valve.
7
Does the tool chest resist dust entry when the dust is blowing at a velocity of 8.9 meters/second (1750 feet/minute)?
Drawing 0627B0000, note 3.8.9
Provide test report for proposed or similar tool chest.
8
Is the tool organizing liner closed-cell, cross-linked foam with a density of 4 to 6 lbs per cubic foot and a water absorption of no more than 0.02 lbs/ft2 over cut surfaces when tested in accordance with ASTM D3575?
drawing 0627C0000
Provide manufacturer’s material specification sheet.