This solicitation requests proposals for an intelligence vault upgrade project. The project scope includes drywall systems, electrical work, security equipment installation, minor HVAC work, and soundproofing upgrades to meet rating requirements. Sole source brand names specified include Corning Edge and Splice Cassette, Kaba Mas X-10 locks, Indalla card readers and Cisco networking equipment for compatibility. The opportunity is set aside exclusively for small businesses with a NAICS code of 236220 and size standard of $39.5 million. The budget range is $100,000 to $250,000. A pre-bid conference will be held on 3 May 2022 and requests for information are due by 18 May 2022. Award is anticipated by 30 September 2022 if funds become available within the competitive price range. The soliciting agency is the Department of the Army National Guard.

View the file

Other files for this federal contract opportunity

Other files attached to 138 FW Intel Vault Upgrade, newest first.
File Type Posted
Attendance Sheet Bid opening Intel Vault_Redacted.pdf PDF
Abstract of Offers Intel Vault.pdf PDF
W50S8U-22-B-0002-0003.pdf PDF
SOW - Intel Vault Conversion v1.9.pdf PDF
22B00020002.pdf PDF
W50S8U-22-B-0002-0001.pdf PDF
RFI_5_MiniSplitPhotos.pdf PDF
E-101 revised.pdf PDF
Pre-Bid RFI Intel Vault 11May22.pdf PDF
Site Visit Sign In - Intel Vault_3May22_Redacted.pdf PDF
Site Visit Slides Intel vault.ppt PPT presentation
Site Visit Minutes - Intel Vault_signed.pdf PDF
Brand_Name_Justification Indalla 1.4.pdf PDF
A101 Final - Drawing.pdf PDF
Upgrade Intel Vault Specs.pdf PDF
Brand_Name_Justification (Cisco_infrastructure) 1.0.pdf PDF
RFI Template Intel Vault Repairs.docx DOCX document
JA Cooper V-line Cabinet.pdf PDF
SOW - Intel Vault Conversion v1.8.pdf PDF
Brand_Name_Justification X-10 1.2.pdf PDF
Brand_Name_Justification (Corning_FODP) 1.0.pdf PDF
W50S8U-22-B-0002.pdf PDF
JA APC Smart-UPS.pdf PDF
Show all 23

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CO

M

BA

A IR

M

AND

CO

M

T

AutoCAD SHX Text

WALL SECTION

AutoCAD SHX Text 3/4" = 1'-0"

AutoCAD SHX Text A

AutoCAD SHX Text OKLAHOMA AIR NATIONAL GUARD - 138th FIGHTER WING

AutoCAD SHX Text

DEPARTMENT OF THE ARMY AND THE AIR FORCE

AutoCAD SHX Text

NATIONAL GUARD BUREAU - WASHINGTON,D.C.

AutoCAD SHX Text A-501

AutoCAD SHX Text of sheets

AutoCAD SHX Text

OF

AutoCAD SHX Text 3/4"=1'-0"

AutoCAD SHX Text Checked By:

AutoCAD SHX Text Scale:

AutoCAD SHX Text Sheet

AutoCAD SHX Text Drawn By:

AutoCAD SHX Text

JC

AutoCAD SHX Text

REVISION:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text 05/11/2022

AutoCAD SHX Text

XHZG20161734

AutoCAD SHX Text

TULSA I.A.P., OKLAHOMA

AutoCAD SHX Text

BCE: LT COL KURT STEPHENS

AutoCAD SHX Text 138th CIVIL ENGINEER SQUADRON

AutoCAD SHX Text

OKLAHOMA AIR NATIONAL GUARD TULSA I.A.P. OK.

AutoCAD SHX Text

DBCE: MAJ PATRICK DEERING

AutoCAD SHX Text

BOTTOM OF DECK

AutoCAD SHX Text FIRE SAFE NON-SHRINK GROUT, OR ACOUSTIC SEALANT IN ALL VOIDS ABOVE TRACK AND BOTH SDIES OF PARTITION

AutoCAD SHX Text SCHEDULED WALL FINISH TO BE CONTINUOUS ABOVE FALSE CEILING AND BELOW RAISED FLOOR

AutoCAD SHX Text

ENTIRE WALL ASSEMBLY SHALL BE

AutoCAD SHX Text

FINISHED AND PAINTED FROM TRUE

AutoCAD SHX Text

FLOOR TO TRUE CEILING

AutoCAD SHX Text

5/8" GYPSUM WALL BOARD (GWB)

AutoCAD SHX Text

SOUND GROUP 4 REQUIRES

AutoCAD SHX Text

ADDITIONAL LAYER OF 5/8" GWB

AutoCAD SHX Text

TWO LAYERS OF 5/8" GYPSUM WALL BOARD (GWB) MOUNTED ON 16 GAUGE METAL FRAMING

AutoCAD SHX Text SOUND ATTENUATION MATERIAL, FASTENED TO PREVENT SLIDING DOWN AND LEAVING VOID AT THE TOP

AutoCAD SHX Text 16 GAUGE CONTINUOUS TRACK (TOP AND BOTTOM) WITH ANCHORS AT 32" O.C. MAXIMUM- BED IN CONTINUOUSE BEAD OF ACOUSTICAL SEALANT

AutoCAD SHX Text

FINISH FLOOR

AutoCAD SHX Text

CONTINUOUS ACOUSTIC SEALANT

AutoCAD SHX Text

IN VOID - BOTH SIDES OF

AutoCAD SHX Text

PARTITION

AutoCAD SHX Text

SCHEDULED WALL BASE, BOTH SIDES OF PARTITION

AutoCAD SHX Text

1. PARTITION SHALL BE SEALED CONTINUOUSLY WITH ACOUSTICAL SEALANT PARTITION SHALL BE SEALED CONTINUOUSLY WITH ACOUSTICAL SEALANT WHENEVER IT ABUTS ANOTHER ELEMENT (E.G., WALL, COLUMN, MULLION, ETC). 2. ANY ELECTRICAL OR COMMUNICATIONS OUTLETS REQUIRED ON THE ANY ELECTRICAL OR COMMUNICATIONS OUTLETS REQUIRED ON THE PERIMETER WALL SHALL BE SURFACE MOUNTED.

AutoCAD SHX Text

DUCT SECURITY BAR DETAIL

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text B

AutoCAD SHX Text

DUCT

AutoCAD SHX Text 3/16

AutoCAD SHX Text

TYPICAL THRU-OUT

AutoCAD SHX Text

6" O.C. HORIZONTALLY AND VERTICALLY

AutoCAD SHX Text

6 OZ. RIVETS 6" O.C. MAX SPACING ALL AROUND DUCT FRAME

AutoCAD SHX Text

1/2" RODS 600/650 BRINELL RATING (TYPICAL)

AutoCAD SHX Text

1" X 1/4" FLAT BAR ROLLED FRAME. WELD RODS TO FRAME

AutoCAD SHX Text ACCCESS DOOR TO INSPECT BARS (INSTALL ON BOTTOM OF DUCT - SHOWN ON SIDE FOR CLARITY)

AutoCAD SHX Text

1. REMOVE ALL EXCESS SLAG, BREAK ALL CORNERS, AND POLISH TO REMOVE ALL EXCESS SLAG, BREAK ALL CORNERS, AND POLISH TO PROVIDE SMOOTH SURFACES. 2. SECURITY BARS NOT REQUIRED IN DUCTS LESS THAN 96 SQUARE INCHES SECURITY BARS NOT REQUIRED IN DUCTS LESS THAN 96 SQUARE INCHES IN CROSS SECTIONAL AREA.

AutoCAD SHX Text

INTEL VAULT