WALL SECTION.pdf
PDF 102 KB Posted
- Attached to
- 138 FW Intel Vault Upgrade Federal contract opportunity
- Solicitation number
- W50S8U-22-B-0002
- Issued by
- Department of the Army National Guard
About this file
This solicitation requests proposals for an intelligence vault upgrade project. The project scope includes drywall systems, electrical work, security equipment installation, minor HVAC work, and soundproofing upgrades to meet rating requirements. Sole source brand names specified include Corning Edge and Splice Cassette, Kaba Mas X-10 locks, Indalla card readers and Cisco networking equipment for compatibility. The opportunity is set aside exclusively for small businesses with a NAICS code of 236220 and size standard of $39.5 million. The budget range is $100,000 to $250,000. A pre-bid conference will be held on 3 May 2022 and requests for information are due by 18 May 2022. Award is anticipated by 30 September 2022 if funds become available within the competitive price range. The soliciting agency is the Department of the Army National Guard.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attendance Sheet Bid opening Intel Vault_Redacted.pdf | ||
| Abstract of Offers Intel Vault.pdf | ||
| W50S8U-22-B-0002-0003.pdf | ||
| SOW - Intel Vault Conversion v1.9.pdf | ||
| 22B00020002.pdf | ||
| W50S8U-22-B-0002-0001.pdf | ||
| RFI_5_MiniSplitPhotos.pdf | ||
| E-101 revised.pdf | ||
| Pre-Bid RFI Intel Vault 11May22.pdf | ||
| Site Visit Sign In - Intel Vault_3May22_Redacted.pdf | ||
| Site Visit Slides Intel vault.ppt | PPT presentation | |
| Site Visit Minutes - Intel Vault_signed.pdf | ||
| Brand_Name_Justification Indalla 1.4.pdf | ||
| A101 Final - Drawing.pdf | ||
| Upgrade Intel Vault Specs.pdf | ||
| Brand_Name_Justification (Cisco_infrastructure) 1.0.pdf | ||
| RFI Template Intel Vault Repairs.docx | DOCX document | |
| JA Cooper V-line Cabinet.pdf | ||
| SOW - Intel Vault Conversion v1.8.pdf | ||
| Brand_Name_Justification X-10 1.2.pdf | ||
| Brand_Name_Justification (Corning_FODP) 1.0.pdf | ||
| W50S8U-22-B-0002.pdf | ||
| JA APC Smart-UPS.pdf |
Show all 23
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CO
M
BA
A IR
M
AND
CO
M
T
AutoCAD SHX Text
WALL SECTION
AutoCAD SHX Text 3/4" = 1'-0"
AutoCAD SHX Text A
AutoCAD SHX Text OKLAHOMA AIR NATIONAL GUARD - 138th FIGHTER WING
AutoCAD SHX Text
DEPARTMENT OF THE ARMY AND THE AIR FORCE
AutoCAD SHX Text
NATIONAL GUARD BUREAU - WASHINGTON,D.C.
AutoCAD SHX Text A-501
AutoCAD SHX Text of sheets
AutoCAD SHX Text
OF
AutoCAD SHX Text 3/4"=1'-0"
AutoCAD SHX Text Checked By:
AutoCAD SHX Text Scale:
AutoCAD SHX Text Sheet
AutoCAD SHX Text Drawn By:
AutoCAD SHX Text
JC
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text 05/11/2022
AutoCAD SHX Text
XHZG20161734
AutoCAD SHX Text
TULSA I.A.P., OKLAHOMA
AutoCAD SHX Text
BCE: LT COL KURT STEPHENS
AutoCAD SHX Text 138th CIVIL ENGINEER SQUADRON
AutoCAD SHX Text
OKLAHOMA AIR NATIONAL GUARD TULSA I.A.P. OK.
AutoCAD SHX Text
DBCE: MAJ PATRICK DEERING
AutoCAD SHX Text
BOTTOM OF DECK
AutoCAD SHX Text FIRE SAFE NON-SHRINK GROUT, OR ACOUSTIC SEALANT IN ALL VOIDS ABOVE TRACK AND BOTH SDIES OF PARTITION
AutoCAD SHX Text SCHEDULED WALL FINISH TO BE CONTINUOUS ABOVE FALSE CEILING AND BELOW RAISED FLOOR
AutoCAD SHX Text
ENTIRE WALL ASSEMBLY SHALL BE
AutoCAD SHX Text
FINISHED AND PAINTED FROM TRUE
AutoCAD SHX Text
FLOOR TO TRUE CEILING
AutoCAD SHX Text
5/8" GYPSUM WALL BOARD (GWB)
AutoCAD SHX Text
SOUND GROUP 4 REQUIRES
AutoCAD SHX Text
ADDITIONAL LAYER OF 5/8" GWB
AutoCAD SHX Text
TWO LAYERS OF 5/8" GYPSUM WALL BOARD (GWB) MOUNTED ON 16 GAUGE METAL FRAMING
AutoCAD SHX Text SOUND ATTENUATION MATERIAL, FASTENED TO PREVENT SLIDING DOWN AND LEAVING VOID AT THE TOP
AutoCAD SHX Text 16 GAUGE CONTINUOUS TRACK (TOP AND BOTTOM) WITH ANCHORS AT 32" O.C. MAXIMUM- BED IN CONTINUOUSE BEAD OF ACOUSTICAL SEALANT
AutoCAD SHX Text
FINISH FLOOR
AutoCAD SHX Text
CONTINUOUS ACOUSTIC SEALANT
AutoCAD SHX Text
IN VOID - BOTH SIDES OF
AutoCAD SHX Text
PARTITION
AutoCAD SHX Text
SCHEDULED WALL BASE, BOTH SIDES OF PARTITION
AutoCAD SHX Text
1. PARTITION SHALL BE SEALED CONTINUOUSLY WITH ACOUSTICAL SEALANT PARTITION SHALL BE SEALED CONTINUOUSLY WITH ACOUSTICAL SEALANT WHENEVER IT ABUTS ANOTHER ELEMENT (E.G., WALL, COLUMN, MULLION, ETC). 2. ANY ELECTRICAL OR COMMUNICATIONS OUTLETS REQUIRED ON THE ANY ELECTRICAL OR COMMUNICATIONS OUTLETS REQUIRED ON THE PERIMETER WALL SHALL BE SURFACE MOUNTED.
AutoCAD SHX Text
DUCT SECURITY BAR DETAIL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text B
AutoCAD SHX Text
DUCT
AutoCAD SHX Text 3/16
AutoCAD SHX Text
TYPICAL THRU-OUT
AutoCAD SHX Text
6" O.C. HORIZONTALLY AND VERTICALLY
AutoCAD SHX Text
6 OZ. RIVETS 6" O.C. MAX SPACING ALL AROUND DUCT FRAME
AutoCAD SHX Text
1/2" RODS 600/650 BRINELL RATING (TYPICAL)
AutoCAD SHX Text
1" X 1/4" FLAT BAR ROLLED FRAME. WELD RODS TO FRAME
AutoCAD SHX Text ACCCESS DOOR TO INSPECT BARS (INSTALL ON BOTTOM OF DUCT - SHOWN ON SIDE FOR CLARITY)
AutoCAD SHX Text
1. REMOVE ALL EXCESS SLAG, BREAK ALL CORNERS, AND POLISH TO REMOVE ALL EXCESS SLAG, BREAK ALL CORNERS, AND POLISH TO PROVIDE SMOOTH SURFACES. 2. SECURITY BARS NOT REQUIRED IN DUCTS LESS THAN 96 SQUARE INCHES SECURITY BARS NOT REQUIRED IN DUCTS LESS THAN 96 SQUARE INCHES IN CROSS SECTIONAL AREA.
AutoCAD SHX Text
INTEL VAULT
File details come from the government source that posted it. Updated .