HAAW179035_Elec_Comm_ADDENDUM-001.pdf
PDF 1 MB Posted
- Attached to
- Squadron Operations Center Build / Upgrade Federal contract opportunity
- Solicitation number
- W50S8N20B0001
- Issued by
- Department of the Army National Guard
About this file
This document package includes construction drawings and specifications for upgrades to an existing National Guard facility. The project involves a new 3,365 square foot addition and renovations to Building 643 at Hancock Field Air National Guard Base in Syracuse, New York. Electrical, telecommunications, and security demolition plans are provided detailing the scope of work. Enlarged telecommunications plans show device locations and cabling requirements. The related federal contract opportunity is a total small business set-aside between $1 million to $5 million soliciting bids for construction services in accordance with the provided plans and specifications. The pre-bid conference and site visit are highly encouraged. Bids are due through the SAM portal and must address all line items. Funding for one CLIN is currently unavailable but anticipated by September 30, 2020. The project has priority list status contingent upon available funds and prices.
View the file
Other files for this federal contract opportunity
Show all 32
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
J
M M
B C E F H J K L M N P Q R S
11.1
AABBCCDDEE
19.4
17.8
17.2
15.2
13.1
11.5
9.9
MISSION
PLANNING
SIMULATOR
174A
OFFICE
174B
OFFICE
174C
COMM CLOSET
CORR
SSO
COMM RM #2
MISSION
PLANNING
COMM MX
MEN'S
MAN
TRAP
SHIFT BREAK
DINING
137 MEAL KITCHEN
FITNESS
COMM RM #3
STAN EVAL OGV
OG CHIEF
OG / CD
CORRIDOR
FLT / CCs
MAIL/COPY ROOM
ELEC RM #2
117B
STORAGE
CONFERENCE
COMM ROOM
AS / CHIEF
CLOSET
SOC
TRAINING CBT
CENTER
AIR CREW
SCHEDULING
AIR CREW
TRAINING /
RECORDS OFFICE
CORRIDOR
JAN. CLOSET
SHARM OFFICE
COMM ROOM
117A
MECH RM #1
TRAINING ADO
CHEIF OF STAN
EVAL
AIR CREW
TESTING
CLOSET
148A
GENERAL
STORAGE
177D
JAN. CLOSET
WOMEN'S VEST.
WOMEN'S
ELEC RM #1
FIXED GCS
BRIEFING #1
ISSO
INTEL WEAPONS
TACTICS
CLOSET
168A
SERVER ROOM
COMM. WORK
AREA
CONFERENC
GCS MX
E.O.C
JAN. CLOSET
CLOSET
149A
CONTRACTOR
SUPPORT
OSS ADMIN
WORK AREA
RECEPTION
CORRIDOR
CORRIDOR
MEN'S VEST.
LOCKER ROOM
MEN'S ROOM
LOCKER ROOM
WOMEN'S ROOM
ENTRANCE #2
100B
CORRIDOR
177C
CORRIDOR
177B
CORRIDOR
COMMAND POST
AS / DO
OG / CC
CORRIDOR
177A
LIBRARY
DEBREIFIN
BRIEFING
MAN TRAP
BRIEFING
SCIF CORRIDOR
MAIN CORRIDOR
AS / ADMIN
PUB. STORAGE
ACTIVE ICD 705
PERIMETER
PHASE 0
ED03
ED02
ED04
ED01
ED07
ED11
ED04
ED09 ED10
ED05
ED06 ED08
ELEC ROOM
HP-35 HP-46
ED04
ED12
ED12
ED13
ED14
ED15
ED13
ED16
ED04
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
no. date descriptionby ckd
1 1312111098765432
I
H
G
F
E
D
C
B
A
CONSTRUCT REAPER OPERATIONS
CENTER BUILDING 643
HAAW179035
174 ATTACK WING
HANCOCK FIELD AIR NATIONAL GUARD BASE
SYRACUSE, NEW YORK
10 N PARK PLACE, SUITE 330
MORRISTOWN, NEW JERSEY 07960
973-884-8701
BMCD LICENSE NO 000165
103179
F
/2
/2
:5
:2
P
M
103182_E_Central
R-ED102
ELECTRICAL DEMOLITION PLAN
11/28/18
P. KANG A. NELSON
K. DISPOTO
DISCONNECT AND REMOVE EXISTING WALLPACK ABOVE DOOR AND
ADJACENT EM LIGHTING FIXTURE.
DISCONNECT AND REMOVE EXISTING WP/GFI RECEPTACLE.
DISCONNECT AND REMOVE EXISTING DISCONNECTS AND JUNCTION
BOX FOR RTU-4 AND RTU-5. THESE UNITS CURRENTLY SERVE THE
MGCS ROOM.
DISCONNECT AND REMOVE EXISTING GFCI RECEPTACLE AND
FACEPLATE. BACKBOX AND CONDUIT SHALL REMAIN. FILL BACKBOX
WITH ACOUSTICAL PUTTY AND SOUND ATTENUATION BATT TO MEET
REQUIRED STC RATING.
DISCONNECT AND REMOVE EXISTING MGCS 100A, 480V DISCONNECT
AND HUBBELL RECEPTACLE, FEEDERS, SUPPORT, ETC. BACK TO
SOURCE. REFER TO R-E-701 FOR ADDITIONAL INFORMATION.
DISCONNECT AND REMOVE EXISTING MGCS 60A, 480V DISCONNECT,
FEEDER, SUPPORT, ETC. BACK TO SOURCE. REFER TO R-E-701 FOR
ADDITIONAL INFORMATION.
DISCONNECT AND REMOVE EXISTING MGCS GROUND BAR. MAINTAIN
CONTINUITY OF GROUNDING/BONDING SYSTEM AND CONDUCTORS.
PROVIDE NEW GROUND CABLING AS REQUIRED.
DISCONNECT AND REMOVE EXISTING MGCS 2-LAMP, T-8
FLUORESCENT LIGHTING FIXTURES (TYPICAL FOR 6), AND ONE EXIT
SIGN, CONTROLS, BRANCH CIRCUITS, SUPPORTS, ETC. SAFE-OFF
BRANCH WIRING FOR CONNECTION TO NEW LED LIGHTING FIXTURES
IN OPEN OFFICE/MGCS.
DISCONNECT AND RELOCATE EXISTING MGCS 100A, 480V DISCONNECT
AND HUBBELL RECEPTACLE.
DISCONNECT AND RELOCATE EXISTING MGCS 60A, 480V DISCONNECT.
DISCONNECT AND RELOCATE EXISTING GROUND BAR. MAINTAIN
CONTINUITY OF GROUNDING/BONDING SYSTEM AND CONDUCTORS.
DISCONNECT AND REMOVE EXISTING DISCONNECT SWITCH, JUNCTION
BOX, SUPPORTS AND ASSOCIATED FEEDERS SERVING EACH 'HP' UNIT
BACK TO SOURCE.
ACTIVE ICD 705 PERIMETER PHASE 1. SEE DRAWING R-G-003 FOR
OVERALL PHASING OF ICD 705 PERIMETER. WALLS WILL NEED TO BE
UPGRADED PRIOR TO REMOVAL OF OTHER ITEMS NOT MOUNTED ON
AFFECTED WALLS.
DISCONNECT AND REMOVE EXISTING WALLPACK LIGHTING FIXTURE.
DISCONNECT AND REMOVE EXISTING 400A, MLO, 208Y/120V, 3Ø, 4W
DISTRIBUTION BOARD INSTALLED UNDER THE UPS SHELTER PROJECT.
DISCONNECT AND REMOVE EXISTING LIGHT SWITCH AND FACEPLATE.
BACKBOX AND CONDUIT SHALL REMAIN. FILL BACKBOX WITH
ACOUSTICAL PUTTY AND SOUND ATTENUATION BATT TO MEET
REQUIRED STC RATING.
ED01
ED02
ED03
ED04
ED05
ED06
ED07
ED08
ED09
ED10
ED11
ED12
ED13
ED14
ED15
ED16
KEYED NOTES: ED##
NOTES:
1. ROOM NAMES AND NUMBERS ON THIS DRAWING REFERENCE EXISTING
CONDITIONS ONLY.
2. REFER TO ARCHITECTURAL DRAWINGS FOR THE EXTENT OF
DEMOLITION WORK.
ELECTRICAL DEMOLITION PLAN
SCALE IN FEET
0 8' 16' 24'
NORTH
A 01/03/19 PK AAC MOCA
B 01/18/19 PK AAC TYPE B-1 SUBMITTAL
C 05/20/19 PK AAC TYPE B-2 SUBMITTAL
D 07/26/19 PK AAC TYPE B-2 SUBMITTAL TO NGB
E 12/09/19 PK AAC TYPE B-3 SUBMITTAL
F 02/20/20 AAC AAC ADDENDUM 001
F
F
F
B C E F H J K L M N P Q R S
11.1
AABBCCDDEE
19.4
17.8
17.2
15.2
13.1
11.5
9.9
MISSION
PLANNING
SIMULATOR
174A
OFFICE
174B
OFFICE
174C
COMM CLOSET
CORR
SSO
COMM RM #2
MISSION
PLANNING
COMM MX
MEN'S
MAN
TRAP
SHIFT BREAK
DINING
137 MEAL KITCHEN
FITNESS
COMM RM #3
STAN EVAL OGV
OG CHIEF
OG / CD
CORRIDOR
FLT / CCs
MAIL/COPY ROOM
ELEC RM #2
117B
STORAGE
CONFERENCE
COMM ROOM
AS / CHIEF
CLOSET
SOC
TRAINING CBT
CENTER
AIR CREW
SCHEDULING
120 AIR CREW
TRAINING /
RECORDS OFFICE
CORRIDOR
JAN. CLOSET
SHARM OFFICE
COMM ROOM
117A
MECH RM #1
TRAINING ADO
CHEIF OF STAN
EVAL
AIR CREW
TESTING
CLOSET
148A
GENERAL
STORAGE
177D
JAN. CLOSET
WOMEN'S VEST.
WOMEN'S
ELEC RM #1
FIXED GCS
BRIEFING #1
ISSO
INTEL WEAPONS
TACTICS
CLOSET
168A
SERVER ROOM
COMM. WORK
AREA
CONFERENC
GCS MX
E.O.C
JAN. CLOSET
CLOSET
149A
CONTRACTOR
SUPPORT
OSS ADMIN
WORK AREA
RECEPTION
CORRIDOR
CORRIDOR
MEN'S VEST.
LOCKER ROOM
MEN'S ROOM
LOCKER ROOM
WOMEN'S ROOM
ENTRANCE #2
100B
CORRIDOR
177C
CORRIDOR
177B
CORRIDOR
COMMAND POST
AS / DO
OG / CC
CORRIDOR
177A
LIBRARY
DEBREIFIN
BRIEFING
MAN TRAP
BRIEFING
SCIF CORRIDOR
MAIN CORRIDOR
AS / ADMIN
PUB. STORAGE
ACTIVE
ICD 705 PERIMETER
PHASE 0
TD01
MS MS
TD05
TD06 ACS IDS
A C
S B
TD03
TD04
CLOSET
155A
MS
TD09
TD11
B
TD07
TD08
TD10
ELEC ROOM
166ACTIVE
ICD 705
PERIMETER
PHASE 0
ACTIVE
ICD 705
PERIMETER
PHASE 1 & 2
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
no. date descriptionby ckd
1 1312111098765432
I
H
G
F
E
D
C
B
A
CONSTRUCT REAPER OPERATIONS
CENTER BUILDING 643
HAAW179035
174 ATTACK WING
HANCOCK FIELD AIR NATIONAL GUARD BASE
SYRACUSE, NEW YORK
10 N PARK PLACE, SUITE 330
MORRISTOWN, NEW JERSEY 07960
973-884-8701
BMCD LICENSE NO 000165
103179
F
/2
/2
:5
:2
P
M
103182_E_Central
R-TD101
TELECOMMUNICATION & SECURITY
DEMOLITION PLAN
12/13/18
A. CARABILLO A. NELSON
K. DISPOTO
TELECOMMUNICATION &
SECURITY DEMOLITION PLAN
DISCONNECT AND REMOVE EXISTING ROLL DOWN MAGNETIC
CONTACTS, ALONG WITH, BUT NOT LIMITED TO ASSOCIATED
CABLING, CONDUIT, SUPPORTS, ETC. BACK TO SOURCE CONTROL
PANEL. ASSOCIATED DEVICES ARE NOT SHOWN ON THE PLAN.
EXISTING HONEYWELL-VINDICATOR V5 ACS & IDS CONTROL PANELS
AND POWER SUPPLIES SHALL REMAIN.
EXISTING HONEYWELL-VINDICATOR V5 ACS CONTROL PANEL SHALL
REMAIN.
EXISTING BLUE LIGHT SYSTEM SWITCH AND CONTROLLER (LOCATED
IN MAN TRAP 147) SHALL REMAIN.
DISCONNECT AND RELOCATE EXISTING CEILING MOUNTED MOTION
SENSORS. REFER TO DRAWING R-TY401 FOR NEW LOCATIONS.
DISCONNECT AND REMOVE EXISTING MANDOOR MAGNETIC
CONTACTS, ALONG WITH, BUT NOT LIMITED TO ASSOCIATED
CABLING, CONDUIT, SUPPORTS, ETC. BACK TO SOURCE CONTROL
PANEL. ASSOCIATED DEVICES ARE NOT SHOWN ON THE PLAN.
DISCONNECT AND RELOCATE EXISTING WALL MOUNTED BLUE LIGHT.
MAINTAIN CONTINUITY OF EXISTING SYSTEM WIRING AND
FUNCTIONALITY. REFER TO DRAWING R-TY401 FOR NEW LOCATIONS.
BACKBOX AND CONDUIT SHALL REMAIN. FILL BACKBOX WITH
ACOUSTICAL PUTTY AND SOUND ATTENUATION BATT TO MEET
REQUIRED STC RATING.
DISCONNECT AND REMOVE EXISTING MTC CABLE CABINET.
DISCONNECT AND RELOCATE EXISTING MTC CABLE CABINET.
REFER TO DRAWING R-TY404 FOR NEW LOCATION.
EXISTING TELECOMMUNICATION AND SECURITY DEVICES TO
REMAIN.
EXISTING MTC CABLE CABINET TO REMAIN.
TD01
TD02
TD03
TD04
TD05
TD06
TD07
TD08
TD09
TD10
TD11
KEYED NOTES: TD##
SCALE IN FEET
0 8' 16' 24'
NOTES:
1. REPROGRAM EXISTING ACS & IDS CONTROL PANELS AS REQUIRED.
2. EXISTING BLUE LIGHT SYSTEM AND CONTROLS SHALL REMAIN, UON.
3. REFER TO ARCHITECTURAL DRAWING R-AD010 FOR ADDITIONAL
DEMOLITION SCOPE.
NORTH
A 01/03/19 AAC AAC MOCA
B 01/18/19 AAC AAC TYPE B-1 SUBMITTAL
C 05/20/19 AAC AAC TYPE B-2 SUBMITTAL
D 07/26/19 AAC AAC TYPE B-2 SUBMITTAL TO NGB
E 12/09/19 AAC AAC TYPE B-3 SUBMITTAL
F 02/20/20 AAC AAC ADDENDUM 001
F
B C E FBBCCDDEE
19.4
17.8
17.2
15.2
CLASSIFIED
AUDITORIUM
COMM. WORK
AREA
SCIF CORRIDOR
FIXED GCS
T001
T001
STORAGE
GCS MX
5 5 1 5 5
T005
T003 1 1
T002
T0
T0
T0
T003
T006
T004
T005
T006
T006
1 1
V
T010
(TYP OF 5)
T011
T013
CONFERENCE
MISSION
PLANNING
UNCLASSIFIED
AUDITORIUM
LOCKER ROOM
MEN'S VEST.
CORRIDOR
177C
CONTRACTOR
SUPPORT
WOMEN'S
COMM MX
LOCKER ROOM
MEN'S
WOMEN'S VEST.
T018
T020
T019
T020
T022 T022
F1 T021
T013
T013
T016
T012
T014T015
F2 F2
F2 F2F2
T012
T012
T012
T011 T011
T011
T006
T017
ACTIVE ICD 705
BOUNDARY PHASE 4
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
no. date descriptionby ckd
1 1312111098765432
I
H
G
F
E
D
C
B
A
174 ATTACK WING
HANCOCK FIELD AIR NATIONAL GUARD BASE
SYRACUSE, NEW YORK
10 N PARK PLACE, SUITE 330
MORRISTOWN, NEW JERSEY 07960
973-884-8701
BMCD LICENSE NO 000165
103182 HAAW162100
REPAIR SQUADRON OPERATIONS CENTER
BUILDING 643
F
2/
/2
1:
:4
103182_E_Central
S-TN401
TELECOMMUNICATIONS ENLARGED PLAN
01/02/19
A. CARABILLO A. NELSON
K. DISPOTO
TELECOMMUNICATIONS
ENLARGED PLAN
SCALE IN FEET
0 4' 8' 12'
PROVIDE 22-'0" WIDE, 8'-0" HIGH, 3/4" THICK FIRE TREATED A/B GRADE,
PAINTED GRAY PLYWOOD BACKBOARD ALONG ENTIRE WALL.
EXISTING 4-4"C. POE.
EXISTING TGB.
EXISTING CATV MEDIA COUNTER AND RACKS.
REWIRE EXISTING COMMUNICATIONS DEVICES IN ROOM AS INDICATED
TO EXISTING SERVER ROOM 161, UON.
NEW SURFACE MOUNTED COMMUNICATIONS BACKBOX AND CONDUIT.
NIPR WALL OUTLET DISTRIBUTION RACK (GREEN).
TS WALL OUTLET DISTRIBUTION RACK (YELLOW).
SIPRNET WALL OUTLET DISTRIBUTION RACK (RED).
REWIRE EXISTING COMMUNICATIONS FLOOR BOXES AS INDICATED.
REWIRE EXISTING COMMUNICATIONS WALL MOUNTED DEVICES TO
RACKS IN COMM ROOM 117.
EXISTING COMMUNICATIONS DEVICE(S) INSTALLED SURFACE
MOUNTED ON NEWLY CONSTRUCTED ICD 705 WALL. PROVIDE
SURFACE MOUNTED BACKBOX AND CONDUIT. EXTEND EXISTING
COMMUNICATIONS CABLING FROM CEILING PULL BOX DOWN TO
DEVICE.
EXISTING COMMUNICATIONS DEVICE(S) INSTALLED SURFACE
MOUNTED ON NEWLY CONSTRUCTED WALL. PROVIDE SURFACE
MOUNTED BACKBOX AND CONDUIT. EXTEND EXISTING
COMMUNICATIONS CABLING FROM CEILING PULL BOX DOWN TO
DEVICE.
EXISTING CABINETS TO REMAIN.
EXISTING CABINETS RELOCATED (GFGI).
NEW COMMUNICATIONS DEVICE(S) INSTALLED SURFACE MOUNTED ON
NEWLY CONSTRUCTED WALL. PROVIDE SURFACE MOUNTED BACKBOX
AND CONDUIT.
REWIRE EXISTING FLOOR BOX AND WALL MOUNTED
COMMUNICATIONS DEVICES IN THE EXISTING FIXED GCS 163, AS
INDICATED, TO SERVER ROOM 180.
PROVIDE 24" WIDE x 4" DEEP ALUMINUM CENTER HUNG CABLE TRAY
INSTALLED 11'-0" AFF. RUN A #2 AWG INSULATED GROUND
CONDUCTOR THE ENTIRE LENGTH OF THE TRAY AND BONDED TO THE
TRAY WITH MANUFACTURER'S FITTINGS AT EVERY SECTION OF TRAY.
PROVIDE GROUND CONDUCTOR IN 3/4" CONDUIT FROM
COMMUNICATION ROOM GROUND BAR TO CABLE TRAY. SEE BASKET
CABLE TRAY DETAIL ON DRAWING R-TN504. PROVIDE AND MAINTAIN
MINIMUM 12" CLEARANCE ABOVE CABLE TRAY FOR ACCESS, UON.
PROVIDE (4) 4" FIRE RATED CONDUIT SLEEVES THROUGH WALL ABOVE
DOOR. COORDINATE EXACT LOCATIONS WITH EXISTING
PENETRATIONS IN THIS AREA. BASIS OF DESIGN SHALL BE HILTI,
MODEL #CFS-SL SK.
EXTEND 24" WIDE x 4" DEEP CABLE TRAY MINIMUM 4'-0" INTO ROOM.
LOCATE FIBER DISTRIBUTION PANEL BELOW RAISED FLOOR IN AN
EASILY ACCESSIBLE LOCATION. FURNITURE/EQUIPMENT SHALL NOT
BLOCK ACCESS.
EXISTING DEVICES TO REMAIN.
T001
T002
T003
T004
T005
T006
T007
T008
T009
T010
T011
T012
T013
T014
T015
T016
T017
T018
T019
T020
T021
T022
KEYED NOTES: T0##
NOTES:
1. EXISTING COMMUNICATIONS AND SECURITY DEVICES AND CABLING
OUTSIDE AREA OF WORK ARE NOT SHOWN AND ARE EXISTING TO REMAIN.
2. PROVIDE EXPANSION JOINT FITTINGS WHERE REQUIRED. REFER TO
ARCHITECTURAL DRAWINGS FOR LOCATIONS.
3. REFER TO DRAWING S-G-003 FOR OVERALL PHASING OF ICD 705
PERIMITER.
4. PROVIDE PULL STRINGS IN ALL NEW CONDUITS.
NORTH
A 01/03/19 AAC AAC MOCA
B 01/18/19 AAC AAC TYPE B-1 SUBMITTAL
C 05/20/19 AAC AAC TYPE B-2 SUBMITTAL
D 07/26/19 AAC AAC TYPE B-2 SUBMITTAL TO NGB
E 12/09/19 PK AAC TYPE B-3 SUBMITTAL
F 02/20/20 AAC AAC ADDENDUM 001
| Sheets |
| R-ED102 - ELECTRICAL DEMOLITION PLAN |
| R-TD101 - TELECOMMUNICATION & SECURITY DEMOLITION PLAN |
| S-TN401 - TELECOMMUNICATIONS ENLARGED PLAN |
File details come from the government source that posted it. Updated .