HAAW179035_Elec_Comm_ADDENDUM-001.pdf

PDF 1 MB Posted

Attached to
Squadron Operations Center Build / Upgrade Federal contract opportunity
Solicitation number
W50S8N20B0001
Issued by
Department of the Army National Guard

About this file

This document package includes construction drawings and specifications for upgrades to an existing National Guard facility. The project involves a new 3,365 square foot addition and renovations to Building 643 at Hancock Field Air National Guard Base in Syracuse, New York. Electrical, telecommunications, and security demolition plans are provided detailing the scope of work. Enlarged telecommunications plans show device locations and cabling requirements. The related federal contract opportunity is a total small business set-aside between $1 million to $5 million soliciting bids for construction services in accordance with the provided plans and specifications. The pre-bid conference and site visit are highly encouraged. Bids are due through the SAM portal and must address all line items. Funding for one CLIN is currently unavailable but anticipated by September 30, 2020. The project has priority list status contingent upon available funds and prices.

View the file

Other files for this federal contract opportunity

Other files attached to Squadron Operations Center Build / Upgrade, newest first.
File Type Posted
Bid Abstract.pdf PDF
Bid Opening Sign In.pdf PDF
Questions and Answers 29 May 2020.docx DOCX document
W50S8N20B00010004 Amendment.pdf PDF
Questions and Answers 27 May 2020.docx DOCX document
W50S8N20B00010004 Amendment.pdf PDF
W50S8N20B00010003 Amendment.pdf PDF
Questions and Answers 20 May 2020.docx DOCX document
HAAW179035-Addendum 02 - Dwg_R-A-601.pdf PDF
HAAW162100-Addendum 02 - Dwg_S-A-601.pdf PDF
W50S8N20B00010002 Amendment.pdf PDF
Questions and Answers 18 May 2020.docx DOCX document
Tax Form NY ST120_1_fill_in.pdf PDF
HAAW179035-Addendum 02 - Spec_08 14 00.pdf PDF
HAAW179035-Addendum 02 - Spec_23 11 25.pdf PDF
HAAW162100-Addendum 02 - Spec_08 14 00.pdf PDF
HAAW162100-Addendum 02 - Spec_09 29 00.pdf PDF
W50S8N20B00010001 Amendment.pdf PDF
HAAW179035-Addendum 02 - Spec_09 29 00.pdf PDF
W50S8N20B00010001 Amendment.pdf PDF
HAAW179035_Arch_ADDENDUM-001.pdf PDF
HAAW179035_Fire Alarm_ADDENDUM-001.pdf PDF
Pre-bid Slides HAAW179035-HAAW162100.pptx PPTX presentation
B643 Pre-Bid Sign In Sheet.pdf PDF
Attachment 7 - HAAW162100 Drawings.pdf PDF
Attachment 6 - HAAW179035 Drawings.pdf PDF
Attachment 3 - HAAW179035 Vol 2.pdf PDF
Attachment 1 - SOW HAAW179035_162100 25 Mar 2020.docx DOCX document
W50S8N20B0001 IFB Add_Alter B643.pdf PDF
Attachment 5 - HAAW162100 Vol 2.pdf PDF
Attachment 4 - HAAW162100 Vol 1.pdf PDF
Attachment 2 - HAAW179035 Vol 1.pdf PDF
Show all 32

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DN

J

M M

B C E F H J K L M N P Q R S

11.1

AABBCCDDEE

19.4

17.8

17.2

15.2

13.1

11.5

9.9

MISSION

PLANNING

SIMULATOR

174A

OFFICE

174B

OFFICE

174C

COMM CLOSET

CORR

SSO

COMM RM #2

MISSION

PLANNING

COMM MX

MEN'S

MAN

TRAP

SHIFT BREAK

DINING

137 MEAL KITCHEN

FITNESS

COMM RM #3

STAN EVAL OGV

OG CHIEF

OG / CD

CORRIDOR

FLT / CCs

MAIL/COPY ROOM

ELEC RM #2

117B

STORAGE

CONFERENCE

COMM ROOM

AS / CHIEF

CLOSET

SOC

TRAINING CBT

CENTER

AIR CREW

SCHEDULING

AIR CREW

TRAINING /

RECORDS OFFICE

CORRIDOR

JAN. CLOSET

SHARM OFFICE

COMM ROOM

117A

MECH RM #1

TRAINING ADO

CHEIF OF STAN

EVAL

AIR CREW

TESTING

CLOSET

148A

GENERAL

STORAGE

177D

JAN. CLOSET

WOMEN'S VEST.

WOMEN'S

ELEC RM #1

FIXED GCS

BRIEFING #1

ISSO

INTEL WEAPONS

TACTICS

CLOSET

168A

SERVER ROOM

COMM. WORK

AREA

CONFERENC

GCS MX

E.O.C

JAN. CLOSET

CLOSET

149A

CONTRACTOR

SUPPORT

OSS ADMIN

WORK AREA

RECEPTION

CORRIDOR

CORRIDOR

MEN'S VEST.

LOCKER ROOM

MEN'S ROOM

LOCKER ROOM

WOMEN'S ROOM

ENTRANCE #2

100B

CORRIDOR

177C

CORRIDOR

177B

CORRIDOR

COMMAND POST

AS / DO

OG / CC

CORRIDOR

177A

LIBRARY

DEBREIFIN

BRIEFING

MAN TRAP

BRIEFING

SCIF CORRIDOR

MAIN CORRIDOR

AS / ADMIN

PUB. STORAGE

ACTIVE ICD 705

PERIMETER

PHASE 0

ED03

ED02

ED04

ED01

ED07

ED11

ED04

ED09 ED10

ED05

ED06 ED08

ELEC ROOM

HP-35 HP-46

ED04

ED12

ED12

ED13

ED14

ED15

ED13

ED16

ED04

date detailed checkeddesigned ofsheet sheets project contract rev.drawing file

no. date descriptionby ckd

1 1312111098765432

I

H

G

F

E

D

C

B

A

CONSTRUCT REAPER OPERATIONS

CENTER BUILDING 643

HAAW179035

174 ATTACK WING

HANCOCK FIELD AIR NATIONAL GUARD BASE

SYRACUSE, NEW YORK

10 N PARK PLACE, SUITE 330

MORRISTOWN, NEW JERSEY 07960

973-884-8701

BMCD LICENSE NO 000165

103179

F

/2

/2

:5

:2

P

M

103182_E_Central

R-ED102

ELECTRICAL DEMOLITION PLAN

11/28/18

P. KANG A. NELSON

K. DISPOTO

DISCONNECT AND REMOVE EXISTING WALLPACK ABOVE DOOR AND

ADJACENT EM LIGHTING FIXTURE.

DISCONNECT AND REMOVE EXISTING WP/GFI RECEPTACLE.

DISCONNECT AND REMOVE EXISTING DISCONNECTS AND JUNCTION

BOX FOR RTU-4 AND RTU-5. THESE UNITS CURRENTLY SERVE THE

MGCS ROOM.

DISCONNECT AND REMOVE EXISTING GFCI RECEPTACLE AND

FACEPLATE. BACKBOX AND CONDUIT SHALL REMAIN. FILL BACKBOX

WITH ACOUSTICAL PUTTY AND SOUND ATTENUATION BATT TO MEET

REQUIRED STC RATING.

DISCONNECT AND REMOVE EXISTING MGCS 100A, 480V DISCONNECT

AND HUBBELL RECEPTACLE, FEEDERS, SUPPORT, ETC. BACK TO

SOURCE. REFER TO R-E-701 FOR ADDITIONAL INFORMATION.

DISCONNECT AND REMOVE EXISTING MGCS 60A, 480V DISCONNECT,

FEEDER, SUPPORT, ETC. BACK TO SOURCE. REFER TO R-E-701 FOR

ADDITIONAL INFORMATION.

DISCONNECT AND REMOVE EXISTING MGCS GROUND BAR. MAINTAIN

CONTINUITY OF GROUNDING/BONDING SYSTEM AND CONDUCTORS.

PROVIDE NEW GROUND CABLING AS REQUIRED.

DISCONNECT AND REMOVE EXISTING MGCS 2-LAMP, T-8

FLUORESCENT LIGHTING FIXTURES (TYPICAL FOR 6), AND ONE EXIT

SIGN, CONTROLS, BRANCH CIRCUITS, SUPPORTS, ETC. SAFE-OFF

BRANCH WIRING FOR CONNECTION TO NEW LED LIGHTING FIXTURES

IN OPEN OFFICE/MGCS.

DISCONNECT AND RELOCATE EXISTING MGCS 100A, 480V DISCONNECT

AND HUBBELL RECEPTACLE.

DISCONNECT AND RELOCATE EXISTING MGCS 60A, 480V DISCONNECT.

DISCONNECT AND RELOCATE EXISTING GROUND BAR. MAINTAIN

CONTINUITY OF GROUNDING/BONDING SYSTEM AND CONDUCTORS.

DISCONNECT AND REMOVE EXISTING DISCONNECT SWITCH, JUNCTION

BOX, SUPPORTS AND ASSOCIATED FEEDERS SERVING EACH 'HP' UNIT

BACK TO SOURCE.

ACTIVE ICD 705 PERIMETER PHASE 1. SEE DRAWING R-G-003 FOR

OVERALL PHASING OF ICD 705 PERIMETER. WALLS WILL NEED TO BE

UPGRADED PRIOR TO REMOVAL OF OTHER ITEMS NOT MOUNTED ON

AFFECTED WALLS.

DISCONNECT AND REMOVE EXISTING WALLPACK LIGHTING FIXTURE.

DISCONNECT AND REMOVE EXISTING 400A, MLO, 208Y/120V, 3Ø, 4W

DISTRIBUTION BOARD INSTALLED UNDER THE UPS SHELTER PROJECT.

DISCONNECT AND REMOVE EXISTING LIGHT SWITCH AND FACEPLATE.

BACKBOX AND CONDUIT SHALL REMAIN. FILL BACKBOX WITH

ACOUSTICAL PUTTY AND SOUND ATTENUATION BATT TO MEET

REQUIRED STC RATING.

ED01

ED02

ED03

ED04

ED05

ED06

ED07

ED08

ED09

ED10

ED11

ED12

ED13

ED14

ED15

ED16

KEYED NOTES: ED##

NOTES:

1. ROOM NAMES AND NUMBERS ON THIS DRAWING REFERENCE EXISTING

CONDITIONS ONLY.

2. REFER TO ARCHITECTURAL DRAWINGS FOR THE EXTENT OF

DEMOLITION WORK.

ELECTRICAL DEMOLITION PLAN

SCALE IN FEET

0 8' 16' 24'

NORTH

A 01/03/19 PK AAC MOCA

B 01/18/19 PK AAC TYPE B-1 SUBMITTAL

C 05/20/19 PK AAC TYPE B-2 SUBMITTAL

D 07/26/19 PK AAC TYPE B-2 SUBMITTAL TO NGB

E 12/09/19 PK AAC TYPE B-3 SUBMITTAL

F 02/20/20 AAC AAC ADDENDUM 001

F

F

F

B C E F H J K L M N P Q R S

11.1

AABBCCDDEE

19.4

17.8

17.2

15.2

13.1

11.5

9.9

MISSION

PLANNING

SIMULATOR

174A

OFFICE

174B

OFFICE

174C

COMM CLOSET

CORR

SSO

COMM RM #2

MISSION

PLANNING

COMM MX

MEN'S

MAN

TRAP

SHIFT BREAK

DINING

137 MEAL KITCHEN

FITNESS

COMM RM #3

STAN EVAL OGV

OG CHIEF

OG / CD

CORRIDOR

FLT / CCs

MAIL/COPY ROOM

ELEC RM #2

117B

STORAGE

CONFERENCE

COMM ROOM

AS / CHIEF

CLOSET

SOC

TRAINING CBT

CENTER

AIR CREW

SCHEDULING

120 AIR CREW

TRAINING /

RECORDS OFFICE

CORRIDOR

JAN. CLOSET

SHARM OFFICE

COMM ROOM

117A

MECH RM #1

TRAINING ADO

CHEIF OF STAN

EVAL

AIR CREW

TESTING

CLOSET

148A

GENERAL

STORAGE

177D

JAN. CLOSET

WOMEN'S VEST.

WOMEN'S

ELEC RM #1

FIXED GCS

BRIEFING #1

ISSO

INTEL WEAPONS

TACTICS

CLOSET

168A

SERVER ROOM

COMM. WORK

AREA

CONFERENC

GCS MX

E.O.C

JAN. CLOSET

CLOSET

149A

CONTRACTOR

SUPPORT

OSS ADMIN

WORK AREA

RECEPTION

CORRIDOR

CORRIDOR

MEN'S VEST.

LOCKER ROOM

MEN'S ROOM

LOCKER ROOM

WOMEN'S ROOM

ENTRANCE #2

100B

CORRIDOR

177C

CORRIDOR

177B

CORRIDOR

COMMAND POST

AS / DO

OG / CC

CORRIDOR

177A

LIBRARY

DEBREIFIN

BRIEFING

MAN TRAP

BRIEFING

SCIF CORRIDOR

MAIN CORRIDOR

AS / ADMIN

PUB. STORAGE

ACTIVE

ICD 705 PERIMETER

PHASE 0

TD01

MS MS

TD05

TD06 ACS IDS

A C

S B

TD03

TD04

CLOSET

155A

MS

TD09

TD11

B

TD07

TD08

TD10

ELEC ROOM

166ACTIVE

ICD 705

PERIMETER

PHASE 0

ACTIVE

ICD 705

PERIMETER

PHASE 1 & 2

date detailed checkeddesigned ofsheet sheets project contract rev.drawing file

no. date descriptionby ckd

1 1312111098765432

I

H

G

F

E

D

C

B

A

CONSTRUCT REAPER OPERATIONS

CENTER BUILDING 643

HAAW179035

174 ATTACK WING

HANCOCK FIELD AIR NATIONAL GUARD BASE

SYRACUSE, NEW YORK

10 N PARK PLACE, SUITE 330

MORRISTOWN, NEW JERSEY 07960

973-884-8701

BMCD LICENSE NO 000165

103179

F

/2

/2

:5

:2

P

M

103182_E_Central

R-TD101

TELECOMMUNICATION & SECURITY

DEMOLITION PLAN

12/13/18

A. CARABILLO A. NELSON

K. DISPOTO

TELECOMMUNICATION &

SECURITY DEMOLITION PLAN

DISCONNECT AND REMOVE EXISTING ROLL DOWN MAGNETIC

CONTACTS, ALONG WITH, BUT NOT LIMITED TO ASSOCIATED

CABLING, CONDUIT, SUPPORTS, ETC. BACK TO SOURCE CONTROL

PANEL. ASSOCIATED DEVICES ARE NOT SHOWN ON THE PLAN.

EXISTING HONEYWELL-VINDICATOR V5 ACS & IDS CONTROL PANELS

AND POWER SUPPLIES SHALL REMAIN.

EXISTING HONEYWELL-VINDICATOR V5 ACS CONTROL PANEL SHALL

REMAIN.

EXISTING BLUE LIGHT SYSTEM SWITCH AND CONTROLLER (LOCATED

IN MAN TRAP 147) SHALL REMAIN.

DISCONNECT AND RELOCATE EXISTING CEILING MOUNTED MOTION

SENSORS. REFER TO DRAWING R-TY401 FOR NEW LOCATIONS.

DISCONNECT AND REMOVE EXISTING MANDOOR MAGNETIC

CONTACTS, ALONG WITH, BUT NOT LIMITED TO ASSOCIATED

CABLING, CONDUIT, SUPPORTS, ETC. BACK TO SOURCE CONTROL

PANEL. ASSOCIATED DEVICES ARE NOT SHOWN ON THE PLAN.

DISCONNECT AND RELOCATE EXISTING WALL MOUNTED BLUE LIGHT.

MAINTAIN CONTINUITY OF EXISTING SYSTEM WIRING AND

FUNCTIONALITY. REFER TO DRAWING R-TY401 FOR NEW LOCATIONS.

BACKBOX AND CONDUIT SHALL REMAIN. FILL BACKBOX WITH

ACOUSTICAL PUTTY AND SOUND ATTENUATION BATT TO MEET

REQUIRED STC RATING.

DISCONNECT AND REMOVE EXISTING MTC CABLE CABINET.

DISCONNECT AND RELOCATE EXISTING MTC CABLE CABINET.

REFER TO DRAWING R-TY404 FOR NEW LOCATION.

EXISTING TELECOMMUNICATION AND SECURITY DEVICES TO

REMAIN.

EXISTING MTC CABLE CABINET TO REMAIN.

TD01

TD02

TD03

TD04

TD05

TD06

TD07

TD08

TD09

TD10

TD11

KEYED NOTES: TD##

SCALE IN FEET

0 8' 16' 24'

NOTES:

1. REPROGRAM EXISTING ACS & IDS CONTROL PANELS AS REQUIRED.

2. EXISTING BLUE LIGHT SYSTEM AND CONTROLS SHALL REMAIN, UON.

3. REFER TO ARCHITECTURAL DRAWING R-AD010 FOR ADDITIONAL

DEMOLITION SCOPE.

NORTH

A 01/03/19 AAC AAC MOCA

B 01/18/19 AAC AAC TYPE B-1 SUBMITTAL

C 05/20/19 AAC AAC TYPE B-2 SUBMITTAL

D 07/26/19 AAC AAC TYPE B-2 SUBMITTAL TO NGB

E 12/09/19 AAC AAC TYPE B-3 SUBMITTAL

F 02/20/20 AAC AAC ADDENDUM 001

F

B C E FBBCCDDEE

19.4

17.8

17.2

15.2

CLASSIFIED

AUDITORIUM

COMM. WORK

AREA

SCIF CORRIDOR

FIXED GCS

T001

T001

STORAGE

GCS MX

5 5 1 5 5

T005

T003 1 1

T002

T0

T0

T0

T003

T006

T004

T005

T006

T006

1 1

V

T010

(TYP OF 5)

T011

T013

CONFERENCE

MISSION

PLANNING

UNCLASSIFIED

AUDITORIUM

LOCKER ROOM

MEN'S VEST.

CORRIDOR

177C

CONTRACTOR

SUPPORT

WOMEN'S

COMM MX

LOCKER ROOM

MEN'S

WOMEN'S VEST.

T018

T020

T019

T020

T022 T022

F1 T021

T013

T013

T016

T012

T014T015

F2 F2

F2 F2F2

T012

T012

T012

T011 T011

T011

T006

T017

ACTIVE ICD 705

BOUNDARY PHASE 4

date detailed checkeddesigned ofsheet sheets project contract rev.drawing file

no. date descriptionby ckd

1 1312111098765432

I

H

G

F

E

D

C

B

A

174 ATTACK WING

HANCOCK FIELD AIR NATIONAL GUARD BASE

SYRACUSE, NEW YORK

10 N PARK PLACE, SUITE 330

MORRISTOWN, NEW JERSEY 07960

973-884-8701

BMCD LICENSE NO 000165

103182 HAAW162100

REPAIR SQUADRON OPERATIONS CENTER

BUILDING 643

F

2/

/2

1:

:4

103182_E_Central

S-TN401

TELECOMMUNICATIONS ENLARGED PLAN

01/02/19

A. CARABILLO A. NELSON

K. DISPOTO

TELECOMMUNICATIONS

ENLARGED PLAN

SCALE IN FEET

0 4' 8' 12'

PROVIDE 22-'0" WIDE, 8'-0" HIGH, 3/4" THICK FIRE TREATED A/B GRADE,

PAINTED GRAY PLYWOOD BACKBOARD ALONG ENTIRE WALL.

EXISTING 4-4"C. POE.

EXISTING TGB.

EXISTING CATV MEDIA COUNTER AND RACKS.

REWIRE EXISTING COMMUNICATIONS DEVICES IN ROOM AS INDICATED

TO EXISTING SERVER ROOM 161, UON.

NEW SURFACE MOUNTED COMMUNICATIONS BACKBOX AND CONDUIT.

NIPR WALL OUTLET DISTRIBUTION RACK (GREEN).

TS WALL OUTLET DISTRIBUTION RACK (YELLOW).

SIPRNET WALL OUTLET DISTRIBUTION RACK (RED).

REWIRE EXISTING COMMUNICATIONS FLOOR BOXES AS INDICATED.

REWIRE EXISTING COMMUNICATIONS WALL MOUNTED DEVICES TO

RACKS IN COMM ROOM 117.

EXISTING COMMUNICATIONS DEVICE(S) INSTALLED SURFACE

MOUNTED ON NEWLY CONSTRUCTED ICD 705 WALL. PROVIDE

SURFACE MOUNTED BACKBOX AND CONDUIT. EXTEND EXISTING

COMMUNICATIONS CABLING FROM CEILING PULL BOX DOWN TO

DEVICE.

EXISTING COMMUNICATIONS DEVICE(S) INSTALLED SURFACE

MOUNTED ON NEWLY CONSTRUCTED WALL. PROVIDE SURFACE

MOUNTED BACKBOX AND CONDUIT. EXTEND EXISTING

COMMUNICATIONS CABLING FROM CEILING PULL BOX DOWN TO

DEVICE.

EXISTING CABINETS TO REMAIN.

EXISTING CABINETS RELOCATED (GFGI).

NEW COMMUNICATIONS DEVICE(S) INSTALLED SURFACE MOUNTED ON

NEWLY CONSTRUCTED WALL. PROVIDE SURFACE MOUNTED BACKBOX

AND CONDUIT.

REWIRE EXISTING FLOOR BOX AND WALL MOUNTED

COMMUNICATIONS DEVICES IN THE EXISTING FIXED GCS 163, AS

INDICATED, TO SERVER ROOM 180.

PROVIDE 24" WIDE x 4" DEEP ALUMINUM CENTER HUNG CABLE TRAY

INSTALLED 11'-0" AFF. RUN A #2 AWG INSULATED GROUND

CONDUCTOR THE ENTIRE LENGTH OF THE TRAY AND BONDED TO THE

TRAY WITH MANUFACTURER'S FITTINGS AT EVERY SECTION OF TRAY.

PROVIDE GROUND CONDUCTOR IN 3/4" CONDUIT FROM

COMMUNICATION ROOM GROUND BAR TO CABLE TRAY. SEE BASKET

CABLE TRAY DETAIL ON DRAWING R-TN504. PROVIDE AND MAINTAIN

MINIMUM 12" CLEARANCE ABOVE CABLE TRAY FOR ACCESS, UON.

PROVIDE (4) 4" FIRE RATED CONDUIT SLEEVES THROUGH WALL ABOVE

DOOR. COORDINATE EXACT LOCATIONS WITH EXISTING

PENETRATIONS IN THIS AREA. BASIS OF DESIGN SHALL BE HILTI,

MODEL #CFS-SL SK.

EXTEND 24" WIDE x 4" DEEP CABLE TRAY MINIMUM 4'-0" INTO ROOM.

LOCATE FIBER DISTRIBUTION PANEL BELOW RAISED FLOOR IN AN

EASILY ACCESSIBLE LOCATION. FURNITURE/EQUIPMENT SHALL NOT

BLOCK ACCESS.

EXISTING DEVICES TO REMAIN.

T001

T002

T003

T004

T005

T006

T007

T008

T009

T010

T011

T012

T013

T014

T015

T016

T017

T018

T019

T020

T021

T022

KEYED NOTES: T0##

NOTES:

1. EXISTING COMMUNICATIONS AND SECURITY DEVICES AND CABLING

OUTSIDE AREA OF WORK ARE NOT SHOWN AND ARE EXISTING TO REMAIN.

2. PROVIDE EXPANSION JOINT FITTINGS WHERE REQUIRED. REFER TO

ARCHITECTURAL DRAWINGS FOR LOCATIONS.

3. REFER TO DRAWING S-G-003 FOR OVERALL PHASING OF ICD 705

PERIMITER.

4. PROVIDE PULL STRINGS IN ALL NEW CONDUITS.

NORTH

A 01/03/19 AAC AAC MOCA

B 01/18/19 AAC AAC TYPE B-1 SUBMITTAL

C 05/20/19 AAC AAC TYPE B-2 SUBMITTAL

D 07/26/19 AAC AAC TYPE B-2 SUBMITTAL TO NGB

E 12/09/19 PK AAC TYPE B-3 SUBMITTAL

F 02/20/20 AAC AAC ADDENDUM 001

Sheets
R-ED102 - ELECTRICAL DEMOLITION PLAN
R-TD101 - TELECOMMUNICATION & SECURITY DEMOLITION PLAN
S-TN401 - TELECOMMUNICATIONS ENLARGED PLAN

File details come from the government source that posted it. Updated .