HAAW162100-Addendum 02 - Dwg_S-A-601.pdf

PDF 138 KB Posted

Attached to
Squadron Operations Center Build / Upgrade Federal contract opportunity
Solicitation number
W50S8N20B0001
Issued by
Department of the Army National Guard

About this file

This document contains a door schedule and door details for a construction project. The schedule lists all doors in the project including door numbers, sizes, materials, frame details, sound ratings, hardware sets, and notes. Standard door and frame types are defined in legends. The project involves renovations and upgrades to an existing squadron operations facility building at Hancock Field Air National Guard Base in Syracuse, New York.

The related federal contract opportunity is a solicitation for construction services for Project No. HAAW179035 to build a new 3,365 square foot addition to the existing building and for Project No. HAAW162100 to renovate and upgrade the existing squadron operations facility building in accordance with provided contract documents, plans, and specifications. The work is being solicited as a total small business set-aside under NAICS code 236220 with a size standard of $39.5 million average annual revenue. The project magnitude is between $1-5 million. A pre-bid conference and site visit are encouraged and failure to bid on all items will result in rejection. The solicitation and amendments are posted at SAM.gov and instructions to obtain plans are in Section 00100. Funding for CLIN 0003 is currently unavailable but is expected to become available by 30 September 2020.

View the file

Other files for this federal contract opportunity

Other files attached to Squadron Operations Center Build / Upgrade, newest first.
File Type Posted
Bid Abstract.pdf PDF
Bid Opening Sign In.pdf PDF
Questions and Answers 29 May 2020.docx DOCX document
W50S8N20B00010004 Amendment.pdf PDF
Questions and Answers 27 May 2020.docx DOCX document
W50S8N20B00010004 Amendment.pdf PDF
W50S8N20B00010003 Amendment.pdf PDF
Questions and Answers 20 May 2020.docx DOCX document
HAAW179035-Addendum 02 - Dwg_R-A-601.pdf PDF
Tax Form NY ST120_1_fill_in.pdf PDF
HAAW179035-Addendum 02 - Spec_08 14 00.pdf PDF
HAAW179035-Addendum 02 - Spec_23 11 25.pdf PDF
HAAW162100-Addendum 02 - Spec_08 14 00.pdf PDF
W50S8N20B00010002 Amendment.pdf PDF
Questions and Answers 18 May 2020.docx DOCX document
HAAW162100-Addendum 02 - Spec_09 29 00.pdf PDF
W50S8N20B00010001 Amendment.pdf PDF
HAAW179035-Addendum 02 - Spec_09 29 00.pdf PDF
W50S8N20B00010001 Amendment.pdf PDF
HAAW179035_Fire Alarm_ADDENDUM-001.pdf PDF
HAAW179035_Arch_ADDENDUM-001.pdf PDF
HAAW179035_Elec_Comm_ADDENDUM-001.pdf PDF
Pre-bid Slides HAAW179035-HAAW162100.pptx PPTX presentation
B643 Pre-Bid Sign In Sheet.pdf PDF
Attachment 7 - HAAW162100 Drawings.pdf PDF
Attachment 6 - HAAW179035 Drawings.pdf PDF
Attachment 3 - HAAW179035 Vol 2.pdf PDF
Attachment 1 - SOW HAAW179035_162100 25 Mar 2020.docx DOCX document
W50S8N20B0001 IFB Add_Alter B643.pdf PDF
Attachment 5 - HAAW162100 Vol 2.pdf PDF
Attachment 4 - HAAW162100 Vol 1.pdf PDF
Attachment 2 - HAAW179035 Vol 1.pdf PDF
Show all 32

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

SCHEDULE

DOOR PER A

B

S C

H E

D U

L E

D O

O R

P E

R

D O

O R

P E

R S

C H

E D

U L E

SCHEDULE

DOOR PER

F1

FRAME TYPES DOOR TYPES

date detailed checkeddesigned ofsheet sheets project contract rev.drawing file

no. date descriptionby ckd

1 1312111098765432

I

H

G

F

E

D

C

B

A

174 ATTACK WING

HANCOCK FIELD AIR NATIONAL GUARD BASE

SYRACUSE, NEW YORK

10 N PARK PLACE, SUITE 330

MORRISTOWN, NEW JERSEY 07960

973-884-8701

BMCD LICENSE NO 000165

103182 HAAW162100

REPAIR SQUADRON OPERATIONS CENTER

BUILDING 643

H

/1

/2

:4

:4

P

M

Proj. No._A_CENTRAL

S-A-601

DOOR SCHEDULE

11/28/18

B. BAKAS B. BAKAS

C. REED

DOOR SCHEDULE SQUAD OPS

DOOR

NUMBER

DOOR FRAME

ASSEMBLY

RATING STC

DETAIL

CARD

READER

HARDWARE

SET REMARKS

SIZE

TYPE MATERIAL FINISH TYPE MATERIAL FINISH HEAD JAMB SILL

PAIR

DOOR WIDTH HEIGHT

SquadOps

147A - 3' - 0" 7' - 0" F WD FF-1 1.1 HM PE-4 - 50 1A / S-A-611 1D / S-A-611 1G / S-A-611 Yes 2.0 3

147B - 3' - 0" 7' - 0" F WD FF-1 1.1 HM PE-4 - 50 1A / S-A-611 1D / S-A-611 1G / S-A-611 Yes 1.0 2,3

154A - 3' - 0" 7' - 0" F WD FF-1 1.1 - PE-4 - 50 Yes 3.0 2,3,4

160 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM PE-4 - - 4A / S-A-611 4D / S-A-611 4G / S-A-611 No 4.0

163A PR. 3' - 0" 7' - 0" F-IN HM PE-3 1.1 HM PE-4 - 45 4A / S-A-611 4D / S-A-611 4G / S-A-611 No 4.0 1,3,9

173 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM PE-4 - 50 1A / S-A-611 1D / S-A-611 1G / S-A-611 Yes 5.0 3

181B - 3' - 0" 7' - 0" F-IN HM PE-3 1.1 HM PE-4 - 50 4A / R-A-611 4D / R-A-611 4G / R-A-611 No 2.0 1,3,7,8

183 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM PE-4 - - 4A / S-A-611 4D / S-A-611 4G / S-A-611 No 6.0

(DOOR FRAME)

TYPE A B

1.1 2" 2"

(FLUSH PANEL)

TYPE DESCRIPTION

F-IN FLUSH PANEL INSULATED

F FLUSH PANEL

REMARKS KEY:

1. EXIT ONLY, NO EXTERIOR DOOR HARDWARE.

2. X-10 LOCK

3. SOUND CONTROL DOOR ASSEMBLIES

4. SALVAGED DOOR, FRAME AND HARDWARE.

5. EXISTING CARDREADER TO BE REMOVED. HARDWARE MODFIED TO PROVIDE

OFFICE FUNCTION LOCKSET WITH NEW CORES

6. EXISTING CARDREADER TO BE REMOVED. HARDWARE MODFIED TO PROVIDE

STOREROOM FUNCTION LOCKSET WITH NEW CORES

7. REPLACEMENT OF EXISTING DOOR, FRAME SHALL REMAIN. NEW DOOR SHALL BE

SIZED TO FIT EXISTING FRAME.

8. REMOVAL OF EXISTING DOOR FOR INSTALL OF NEW DOOR SHALL NOT PROCEED

UNTIL GOVERNMENT RECIEVES ICD705 ACCREDITATION FOR NEW WORK PART OF

PROJECT DOCUMENTS.

9. CONFIRM EXISTING PRECAST PANEL SUPPORTS PRIOR TO DEMOLITION. MOVE

DOOR LOCATION TO EXTENT POSSIBLE TO MAINTIAN EXISTING PRECAST PANEL

SUPPORTS

GENERAL DOOR SCHEDULE NOTES:

1. ALL EXTERIOR DOORS SHALL HAVE

INSULATED CORE.

DOOR SCHEDULE MODIFIED EXISTING

DOOR

NUMBER

DOOR FRAME

ASSEMBLY

RATING STC

HARDWARE

SET REMARKS

SIZE

MATERIAL MATERIAL

PAIR

DOOR WIDTH HEIGHT

GROUND FLOOR

E149 - 3' - 0" 7' - 0" - - - 7.0 5

E150 - 3' - 0" 7' - 0" - - - 7.0 5

E156 - 3' - 0" 7' - 0" - - - 7.0 5

E158 PR. 3' - 0" 7' - 0" - - - 7.0 5

E161 - 3' - 0" 7' - 0" - - - 8.0 6

E169 - 3' - 0" 7' - 0" - - - 7.0 5

E170 - 3' - 0" 7' - 0" - - - 7.0 5

E171 - 3' - 0" 7' - 0" - - - 8.0 6

E172 - 3' - 0" 7' - 0" - - - 7.0 5

DOOR AND FRAME LEGEND

FINISH

FF-1* FACTORY FINISHED

PE-1** PAINT-EPOXY

MATERIAL

AL ALUMINUM

HM HOLLOW METAL

WD WOOD

SIZE

- SINGLE DOOR

PR PAIR OF DOORS

UPR UNEQUAL PAIR

C 01/18/19 VV BB TYPE B-1 SUBMITTAL

D 05/20/19 VV BB TYPE B-2 SUBMITTAL

E 07/26/19 VV BB TYPE B-2 SUBMITTAL TO NGB

F 12/09/19 VV BB TYPE B-3 SUBMITTAL

H 05/12/20 RA BB ADDENDUM 002

H

H

H

H

H

Sheets
S-A-601 - DOOR SCHEDULE

File details come from the government source that posted it. Updated .