FULLY SPRINKLERED
o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Office of Construction and Facilities Management th re e e ig h th s in c h o n e fo o t
EXPAND SPECIALTY
CARE
SUBMISSIONS
REVISIONS
ARCHITECT/ENGINEERS:
USFin Development, LLC 1105 West Weir Street Litchfield, IL 62056
CONSULTANTS
7260 SHADELAND STATION
INDIANAPOLIS, IN 46256-3957
TEL 317.547.5580 FAX 317.543.0270
www.structurepoint.com
United States Department of Veterans Affairs R. L. Roudebush VAMC 1481 West 10th Street Indianapolis, Indiana 46202
65% DESIGN DEVELOPMENT 1-23-15
95% CONSTRUCTION DOCUMENTS 2-25-15
11FY14100% SUBMITTAL DOCUMENTS 5-29-15
BID DOCUMENTS 5-10-17
/9
/2
:1
:3
A
M C
R e v it \2
\L o c a l C o p ie s \2
V
A In d y O n c o lo g y C
E N
T R
A L R ff a c k e n th a l.
rv t
COVER SHEET
05-10-17
V.A. 583-331
R. L. Roudebush VAMC, Indianapolis, IN
1-GI-001
FF APN
BIDDING DOCUMENTS
This facility contains _ _ asbestos and/or _ _ LBP that will be removed under a seperate contract.
This facility contains asbestos that will be removed under this contract.
This facility contains no known or suspected asbestos or LBP.
This facility contains _ _ asbestos and/or _ _ LBP that will be removed by the VA.
X
ASBESTOS CONTAINING MATERIAL (ACM)
AND LEAD BASED PAINT (LBP) STATEMENT
(Place an "X" in the appropriate box.)
NORTH REFERENCE
LOCATION MAP VICINITY MAP
BUILDING 1-RENOVATE 6TH FLOOR D-WING
E
N
NW
SW
NE
SE
S
W
E
M E
PA
R
N U
D
DE
S TAT E
TI
T
E NT OF V
A I R
S
MA
OS F
I R
E C
A
F
FA
N
ET RA
S
EXPAND SPECIALTY CARE
SHEET NUMBER SHEET NAME
PLUMBING
1-FD101 SIXTH FLOOR D WING FIRE PROTECTION DEMOLITION PLAN
1-FX101 SIXTH FLOOR D WING FIRE PROTECTION PLAN
1-P-001 PLUMBING NOTES, ABBREVIATIONS, LEGEND, AND SCHEDULES
1-PD101 FIFTH FLOOR D WING PLUMBING DEMOLITION PLAN
1-PD102 SIXTH FLOOR D WING PLUMBING DEMOLITION PLAN
1-PD103 SIXTH FLOOR D WING MEDICAL GAS DEMOLITION PLAN
1-PP101 FIFTH FLOOR D WING PLUMBING PLAN
1-PP102 SIXTH FLOOR D WING WASTE AND VENT PLAN
1-PP103 SIXTH FLOOR D WING DOMESTIC WATER PLAN
1-PP104 SIXTH FLOOR MEDICAL GAS PLAN
1-PP105 SEVENTH FLOOR D WING PLUMBING PLAN
1-PL501 PLUMBING DETAILS
1-PP901 SIXTH FLOOR D WING WASTE, VENT, AND STORM ISOMETRIC
1-PP902 SIXTH FLOOR D WING DOMESTIC WATER ISOMETRIC
ELECTRICAL
1-E-001 ELECTRICAL SYMBOLS AND ABBREVIATIONS
1-ED101 SIXTH FLOOR ELECTRICAL DEMOLITION PLAN
1-ED102 SIXTH FLOOR LIGHTING DEMOLITION PLAN
1-ED103 SIXTH FLOOR ELECTRICAL DEMOLITION ABOVE CEILING CONDUIT PLAN
1-ED104 SIXTH FLOOR TECHNOLOGY DEMOLITION PLAN
1-EP101 SIXTH FLOOR POWER PLAN
1-EM101 SIXTH FLOOR MECHANICAL POWER PLAN
1-EM102 D WING ROOF MECHANICAL POWER PLAN
1-ET101 SIXTH FLOOR TECHNOLOGY SYSTEMS PLAN
1-EL101 SIXTH FLOOR LIGHTING PLAN
1-E-401 ELECTRICAL PLAN ENLARGEMENTS
1-E-501 ELECTRICAL DETAILS
1-E-502 ELECTRICAL DETAILS
1-E-503 ELECTRICAL DETAILS
1-E-601 ELECTRICAL SINGLE-LINE DIAGRAM AND EQUIPMENT SCHEDULE
1-E-602 ELECTRICAL PANEL SCHEDULES
1-E-603 ELECTRICAL PANEL SCHEDULES
1-F-101 SIXTH FLOOR FIRE ALARM & LIFE SAFETY DEMOLITION PLAN
1-FA101 SIXTH FLOOR FIRE ALARM LIFE SAFETY PLAN
SHEET NUMBER SHEET NAME
GENERAL
1-GI-001 COVER SHEET
1-GI-002 ABBREVIATIONS & UL RATINGS
1-LS-001 SIXTH FLOOR-LIFE SAFETY PLAN
ARCHITECTURE
1-AD-101 SIXTH FLOOR DEMOLITION PLAN
1-AS-001 WALL TYPES & RATED PARTITIONS
1-AS-101 SIXTH FLOOR-OVERALL
1-AS-102A SIXTH FLOOR-AREA 'A'
1-AS-102B SIXTH FLOOR-AREA 'B', 7TH FLOOR WORK
1-AS-111 SIXTH FLOOR-REFLECTED CEILING PLAN
1-AS-301 SIXTH FLOOR-SECTIONS & DETAILS
1-AS-401 SIXTH FLOOR-SIGNAGE
1-AS-402 SIXTH FLOOR-WALL PROTECTION
1-AS-411 SIXTH FLOOR - ONCOLOGY INTERIOR ELEVATION KEY PLAN
1-AS-412 SIXTH FLOOR - ONCOLOGY INTERIOR ELEVATIONS
1-AS-413 SIXTH FLOOR - ONCOLOGY INTERIOR ELEVATIONS
1-AS-414 SIXTH FLOOR - ONCOLOGY INTERIOR ELEVATIONS
1-AS-417 SIXTH FLOOR - ONCOLOGY PHARMACY & MED PREP INTERIOR ELEVATIONS
1-AS-420 INTERIOR SECTIONS & DETAILS
1-AS-421 ENLARGED PLANS
1-AS-501 SIXTH FLOOR DETAILS
1-AS-601 SIXTH FLOOR-DOOR SCHEDULE & STOREFRONTS
1-AS-701A SIXTH FLOOR - ONCOLOGY FINISH PLAN - AREA "A"
1-AS-701B SIXTH FLOOR - ONCOLOGY FINISH PLAN - AREA "B"
1-AS-801 SIXTH FLOOR - ONCOLOGY EQUIPMENT PLAN - OVERALL
1-AS-801A SIXTH FLOOR - ONCOLOGY EQUIPMENT PLAN - AREA "A"
1-AS-801B SIXTH FLOOR - ONCOLOGY EQUIPMENT PLAN - AREA "B"
1-AS-802A SIXTH FLOOR - ONCOLOGY EQUIPMENT SCHEDULE
1-AS-802B SIXTH FLOOR - ONCOLOGY EQUIPMENT SCHEDULE
1-AS-802C SIXTH FLOOR - ONCOLOGY EQUIPMENT SCHEDULE
MECHANICAL
1-M-001 MECHANICAL NOTES, ABBREVIATIONS, AND LEGEND
1-MD101 SIXTH FLOOR MECHANICAL DEMOLITION PLAN
1-MD102 SIXTH FLOOR MECHANICAL PIPING DEMOLITION PLAN
1-MD103 D WING ROOF MECHANICAL DEMOLITION PLAN
1-MH101 SIXTH FLOOR MECHANICAL HVAC PLAN
1-MH102 D WING ROOF MECHANICAL PLAN
1-MP101 SIXTH FLOOR MECHANICAL PIPING PLAN
1-MP102 D WING ROOF MECHANICAL PIPING PLAN
1-MP103 PARTIAL D WING BASEMENT MECHANICAL PIPING PLAN
1-M-501 MECHANICAL DETAILS
1-M-502 MECHANICAL DETAILS
1-M-503 MECHANICAL DETAILS
1-M-504 CONTROL DETAILS
1-M-505 CONTROL DETAILS
1-M-506 CONTROL DETAILS
1-M-601 MECHANICAL SCHEDULES
1-M-602 MECHANCIAL SCHEDULES
BUILDING 1
BUILDING 5
Revision # Description Date
SHEET INDEX
5-1/2"
System Description
Shaft Wall (Non-loadbearing)
- 1/2" SHEETROCK Brand FIRECODE C Core Gypsum Panels
- RC-1 resilient channel 24" o.c.
- 4" USG C-H Stud 25 gauge 24" o.c.
- 3" mineral wool batt
- 1" SHEETROCK Brand Gypsum Liner Panel
System Performance
2 HR Fire
UL Design No.U415 System F
STC 53 Sound
USG-040909
4-7/8"
System Performance
1HR Fire
UL Design No. U419 or MEA 81-98-M
49 STC
SA-870717System Description
Steel Stud Partition (Non-loadbearing)
- 5/8 in. thick gypsum board applied vertically or horizontally.
- 3-5/8" 20 gauge steel stud 24" o.c.
- 3" mineral wool batt
- 5/8 in. thick gypsum board applied vertically or horizontally.
EARTH
NOTE: PATTERNS SHOWN REPRESENT CUT
MATERIALS IN PLAN OR SECTION, UNLESS
NOTED OTHERWISE.
GRANULAR FILL
CONCRETE, CAST-IN-PLACE
CONCRETE, PRECAST/CAST
STONE
CONCRETE MASONRY UNIT
BRICK MASONRY
STONE: LIMESTONE, GRANITE,
MARBLE OR AS NOTED
METAL: TYPE AS NOTED
METAL: ROLLED SHAPES
WOOD FRAMING / BLOCKING:
CONTINOUS
WOOD SHIM
WOOD/FINISHED,
SHOWN CUT AND ELEVATION
PLYWOOD
PARTICLEBOARD
EIFS
SPRAYED FIREPROOFING
SHOWN ON ROLLED SHAPE
BATT INSULATION: THERMAL
OR ACOUSTICAL, UNO
RIGID INSULATION: THERMAL,
ACOUSTICAL, OR SAFING
SHEATHING: GYPSUM, OR AS
NOTED
GYPSUM WALL BOARD
TILE: CERAMIC, QUARRY, UNO
RESINOUS FLOORING:
TERRAZO, TROWEL-ON, UNO
ACOUSTICAL CEILING TILE
GRATING (PLAN)
INSULATED GLASS:
(SMALL SCALE)
GRATING (SECTION)
MEMBRANE: WATERPROOF,
ROOF, DAMPPROOFING
AIR BARRIER SYSTEM
INSULATED GLASS:
(DETAIL)
TERRA COTTA, STRUCTURAL
CLAY TILE
CARPET, CARPET TILE (DETAIL)
SAND, GROUT
AS NOTED
GLASS FIBER REINFORCED
CONCRETE SIDING OR TRIM
WOOD/ENGINEERED: GLUE
LAMINATED
PLASTER ON METAL LATH
WOOD FLOOR, WOOD
SHINGLES, OR SIDING
STRUCTURAL CORE SIZE
Y6S
PARTITION DESIGNATION
ACOUSTICAL ATTENUATION REQ'D
ENLARGED DRAWING REFERENCE
ELEVATION DATUM REFERENCE
NORTH ARROW
DRAWING NUMBER
SHEET NUMBER
BUILDING SECTION CUT REFERENCE
A
A101
A101
A101
A101
W3
N
A101
KEYED NOTE
REVISION REFERENCE
WINDOW TAG
DOOR TAG
ROOM NAME AND NUMBER
COLUMN GRID NEW
A
DRAWING NUMBER
SHEET NUMBER
WALL SECTION CUT REFERENCE
DRAWING NUMBER
SHEET NUMBER
ELEVATION REFERENCE
WALL TYPE REFERENCE
COLUMN GRID EXISTING
1. EQUIPMENT TAG
1' - 0"
M A
X
4'
M A
X
2'
0"
M
IN
6'
M A
X
3'
1 3/8"
3' - 6" MIN.
1' - 0" MAX.
1/
2" M
IN
6"
MIN.
1' - 0"
MIN.
2' - 0"
1' - 6"
1' - 6"
M A
X
1'
SIDE WALL
OF STALL
TOILET PAPER
DISPENSER
NAPKIN
DISPOSAL
REAR
WALL OF
STALL
B/O
REFLECTIVE
SURFACE
TO ENSURE
FORWARD
REACH
NOTE:
DIMENSIONS SHOWN ARE TO FINISHED WALL
REFER TO MANUFACTURER'S SPECIFIC
RECOMMENDATIONS FOR ADA COMPLIANCE
KNEE & TOE
CLEARANCE
RESTROOM ACCESORIES
ROBE
HOOK
TOWEL
BAR
TOWEL
RING
WALL
SHELF
SPECIMEN
PASS THRU
39"-41"
1/
2" M
IN
MIN.
1' - 3"
M
IN
1'
7"-9"
SOAP
DISPENSER
TOWEL
DISPENSER
TOWEL
DISPENSER /
WASTE
RECEPTACLE
M A
X
3'
M
IN
9"
MIN.
11"
MAX.
6"
17"-25"
MIN.
8"
REAR WALL
GRAB BAR
SIDE WALL
ACCESSORIES
MIRROR
FULLY SPRINKLERED
o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Office of Construction and Facilities Management th re e e ig h th s in c h o n e fo o t
EXPAND SPECIALTY
CARE
SUBMISSIONS
REVISIONS
ARCHITECT/ENGINEERS:
USFin Development, LLC 1105 West Weir Street Litchfield, IL 62056
CONSULTANTS
7260 SHADELAND STATION
INDIANAPOLIS, IN 46256-3957
TEL 317.547.5580 FAX 317.543.0270
www.structurepoint.com
United States Department of Veterans Affairs R. L. Roudebush VAMC 1481 West 10th Street Indianapolis, Indiana 46202
65% DESIGN DEVELOPMENT 1-23-15
95% CONSTRUCTION DOCUMENTS 2-25-15
11FY14100% SUBMITTAL DOCUMENTS 5-29-15
BID DOCUMENTS 5-10-17
/8
/2
:1 :0
P
M C
R e v it \2
\L o c a l C o p ie s \2
V
A In d y O n c o lo g y C
E N
T R
A L R ff a c k e n th a l.
rv t
ABBREVIATIONS & UL RATINGS
05-10-17
V.A. 583-331
R. L. Roudebush VAMC, Indianapolis, IN
1-GI-002
FF APN
BIDDING DOCUMENTS
SYM SYMBOL
SYS SYSTEM
T
T&G TONGUE AND
GROOVE
TAFS TEXTURE APPLIED
FINISH
TB TOWEL BAR
TD TOWEL DISPENSER
TDR TOWEL DISPENSER /
RECEPTACLE
TEL TELEPHONE
TEMP TEMPORARY
TF TOP OF FOOTING
TFF TOP OF FINISH FLOOR
THRES THRESHOLD
TJ TOP OF JOIST
TOT TOTAL
TPH TOILET PAPER
HOLDER
TSL TOP OF SLAB
TST TOP OF STEEL
TYP TYPICAL
U
UNIF UNIFORM
UNO UNLESS NOTED
OTHERWISE
UR URINAL
V
VB VINYL BASE
VCT VINYL COMPOSITION
TILE
VERT VERTICAL
VIN VINYL
VT VINYL TILE
VWC VINYL WALL
COVERING
W
W/W WALL TO WALL
WC WATER CLOSET
WD WOOD
WDW WINDOW
WH WALL HUNG
WT WEIGHT
MLDG MOLDING
MLWK MILLWORK
MO MASONRY OPENING
MTD MOUNTED
MTG MOUNTING
MULL MULLION
MULT MULTIPLE
N
N/A NOT APPLICABLE
ND NAPKIN DISPENSER
NIC NOT IN CONTRACT
NOM NOMINAL
NR NAPKIN RECEPTACLE
NTS NOT TO SCALE
O
O/O OUT TO OUT
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OFCI OWNER FURNISHED -
CONTRACTOR
INSTALLED
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OPP HAND OPPOSITE HAND
OPT OPTIONAL
ORD OVERFLOW ROOF
DRAIN
ORIG ORIGINAL
P
PERIM PERIMETER
PERM PERMANENT
PH PHASE
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTIC
PLBG PLUMBING
PLYWD PLYWOOD
PNL PANEL
PRCST PRECAST
PREFAB PREFABRICATED
PREFIN PREFINISHED
PRELIM PRELIMINARY
PREP PREPARATION
PRKG PARKING
PROJ PROJECT
PT PRETREATED
PTD PAINTED
PTN PARTITION
Q
QT QUARRY TILE
R
R RADIUS
RD ROOF DRAIN
REC RECESSED
RECPT RECEPTACLE
REF REFER(ENCE)
REINF REINFORCE(D)(ING)(M
ENT)
REQD REQUIRED
RESIL RESILIENT
RFG ROOFING
RLG RAILING
RM ROOM
RND ROUND
RO ROUGH OPENING
RTU ROOF TOP UNOT
S
SAN SANITARY
SCW SOLID CORE WOOD
SF SQUARE FOOT
SP STAND PIPE
SPKLR SPRINKLER
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STOR OR ST STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
F
F/F FACE TO FACE
FBD FIBERBOARD
FDN FOUNDATION
FE FIRE EXTINGUISHER
FGL FIBERGLASS
FHC FIRE HOSE CABINET
FHP FULL HEIGHT
PARTITION
FIN FINISH
FIN FL FINISHED FLOOR
FLOUR FLOURESCENT
FLR (FLRG) FLOOR(ING)
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FR FIRE RATING
FTG FOOTING
FURN FURNITURE
FURR FURRING
G
GALV GALVANIZED
GDR GUARDRAIL
GLZ GLAZING
GUT GUTTER
GYP BD/GWB GYPSUM BOARD
H
HC HANDICAP(PED)
HCMU HOLLOW CONCRETE
MASONRY UNIT
HCW HOLLOW CORE WOOD
HDWE/HDW HARDWARE
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HNDRL HANDRAIL
HORIZ HORIZONTAL
HT HEIGHT
HVAC HEATING,
VENTILATION, AIR
CONDITIONING
I
ICF INSULATED
CONCRETE FORM
ID INSIDE DIAMETER
IF INSIDE FACE
INCAND INCANDESCENT
INDIC INDICATE
INS ALUM INSULATED ALUMINUM
INSTL INSTALL(ATION)
INSUL INSULATION
INT INTERIOR
J
JST JOIST
JT JOINT
K
KPL KICKPLATE
L
LAM LAMINATION
LAV LAVATORY
LD BRG LOAD BEARING
LDG LANDING
LF LINEAR FOOT
LRV LOUVERED ROOF
VENT
LTG LIGHTING
LTWT LIGHTWEIGHT
LVR LOUVER
M
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MBRN MEMBRANE
MECH MECHANICAL
MED MEDICINE (MEDICAL)
MET METAL
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
A
A/E ARCHITECT/ENGINEER
ACOUS ACOUSTICAL
ACP ACOUSTICAL CEILING
PANEL
ACT ACOUSTICAL CEILING
TILE
ADA AMERICAN'S WITH
DISABILITIES ACT
ADD ADDENDUM
ADJ ADJACENT
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZED
ARCH ARCHITECT (URAL)
B
BET BETWEEN
BH BULKHEAD
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BOT BOTTOM
BRCG BRACING
BRDG BRICK
BRG BEARING
C
C/C CENTER TO CENTER
CAB CABINET
CB CORNER BEAD
CER CERAMIC
CF CUBIC FOOT
CFCI CONTRACTOR
FURNISHED /
CONTRACTOR
INSTALLED
CGD CORNER GUARD
CHAN CHANNEL
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CMU CONCRETE MASONRY
UNIT
CNTR COUNTER
COLM COLUMN
CONC CONCRETE
CONSTR CONSTRUCTION
CONT CONTINUOUS
CP/CPT CARPET
CRS COLD ROLLED STEEL
CRS COURSE
CRTN CURTAIN
CSMT CASEMENT
CSWK CASEWORK
CUB CUBICLE
D
DEMO DEMOLITION
DF DRINKING FOUNTAIN
DFR DOOR FRAME
DIFF DIFFUSER
DIM DIMENSION
DISP DISPENSER
DLV DOOR LOUVER
DO DOOR OPENING
DS DOWNSPOUT
DT DRAIN TILE
DWG DRAWING
E
EHD ELECTRICAL HAND
DRYER
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
ENCL ENCLOSURE
ENGR ENGINEER
EQUIP EQUIPMENT
ESMT EASEMENT
EWC ELECTRICAL WATER
COOLER
EXST EXISTING
EXT EXTENDER
ARCHITECTURAL ABBREVIATIONS
MATERIALS LEGEND
INTERIOR PARTITION LEGEND
GRAPHIC LEGEND
1 REFER TO SHEET 1-AS-001 FOR WALL HEIGHTS AND TYPE DESCRIPTIONS.
2 SEE SHEET 1-G1-002 FOR GRAPHIC SYMBOL LEGEND.
3 COORDINATE WORK OF ALL TRADES PRIOR TO STARTING
CONSTRUCTION.
4 ALL DIMENSIONS ARE TO GRID LINES, FACE OF STUD FRAMING, FACE OF
EXISTING PARTITIONS OR FACE OF CONCRETE/MASONRY UNITS UNLESS
NOTED OTHERWISE.
5 PROVIDE GYPSUM BOARD CONTROL JOINTS AT WALLS OVER 30'-0" IN
LENGTH. LOCATE ABOVE EDGE OF OPENING WHEN POSSIBLE.
6 AT FIRE RATED WALLS WHERE OPENINGS ARE GREATER THAN 16
SQUARE INCHES OR WHERE TOTAL AREA OF OPENINGS EXCEEDS 100
SQUARE INCHES IN 100 SQUARE FEET, WRAP 5/8" TYPE 'X' GYPSUM
BOARD BEHIND OPENINGS PER U.L. DESIGN #U510.
7 FRAME DOOR OPENINGS 4" FROM FACE OF PERPENDICULAR WALL ON
HINGE SIDE AND 1'-6" FROM FACE OF PERP. WALL ON LATCH SIDE UNLESS
NOTED OTHERWISE.
8 THE CONTRACTORS INVOLVED IN THIS PROJECT SHALL BE RESPONSIBLE
FOR DESIGNING AND INSTALLING THEIR RESPECTIVE WORK AND
SYSTEMS TO MEET ALL APPLICABLE FEDERAL, STATE, AND LOCAL
CODES, LAWS, SAFETY REGULATIONS AND HAZARDOUS WASTE LAWS.
THE CONTRACTORS SHALL FURNISH ALL NECESSARY PERMITS.
9 PROVIDE MOISTURE RESISTANT GYPSUM BOARD IN ALL RESTROOMS
AND WET AREAS.
10 THE CONTRACTOR SHALL REVIEW THE DRAWINGS AND UNDERSTAND
THE SCOPE OF THE DRAWINGS TO BE THE FOLLOWING: THESE
CONSTRUCTION DOCUMENTS (DRAWINGS, SPECIFICATIONS, ADDENDA)
INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF
ARCHITECTURAL DESIGN CONCEPTS, THE DIMENSION OF THE BUILDING,
THE MAJOR ARCHITECTURAL ELEMENTS, AND THE MAJOR STRUCTURAL,
MECHANICAL, AND ELECTRICAL SYSTEMS. THE DOCUMENTS DO NOT
AND ARE NOT INTENDED TO INDICATE OR DESCRIBE IN DETAIL ALL THE
NECESSARY WORK REQUIRED FOR FULL PERFORMANCE OF, AND
COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS
OF THE GENERAL SCOPE INDICATED IN THESE DOCUMENTS, THE TRADE
CONTRACTOR SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER
EXECUTION AND COMPLETION OF THE WORK. ALL WORK SHALL BE
COMPLETE IN EVERY DETAIL AND THE CONTRACTORS SHALL PROVIDE A
ONE YEAR WARRANTY FOR THEIR WORK.
11 DO NOT SCALE DRAWINGS. DIMENSIONS SHALL GOVERN EACH BUILDING
COMPONENT LOCATION. BRING ANY DISCREPANCIES TO THE
ARCHITECT'S ATTENTION IN WRITING IMMEDIATELY.
12 FIRE EXTINGUISHER CABINET LOCATIONS SHOWN ARE SUGGESTED
LOCATIONS ONLY. FIRE EXTINGUISHERS AND CABINETS TO COMPLY
WITH NFPA 101. CONTRACTOR TO VERIFY QUANTITY AND EXACT
LOCATIONS WITH VA SAFETY DIRECTOR PRIOR TO INSTALLATION.
13 BUILDING FIRST FLOOR REFERENCE ELEVATIONS IS 100'-0".
14 ALL WORK SHALL BE PERFORMED IN A SKILLED WORKMANSHIP TYPE AND
MANNER ACCEPTABLE TO THE ARCHITECT AND OWNER.
15 PROVIDE SHEET METAL OR FIRE RETARDANT WOOD BLOCKING IN WALL
CAVITIES FOR ITEMS THAT ARE REQUIRED TO BE SECURED TO THE
WALLS.
16 TAPE AND SPACKLE ALL PENETRATIONS IN GYPSUM BOARD PARTITIONS,
INCLUDING WATER LINES, DRAINS, CONDUIT AND THERMOSTATS.
INSTALL FIRE RETARDANT SEALANT AT PENETRATIONS IN RATED
PARTITIONS AS REQUIRED.
17 CAULK INTERSECTION BETWEEN DIFFERENT MATERIALS.
18 CAULK TOILET FIXTURES TO FLOOR PER SEALANT SCHEDULE IN
SPECIFICATIONS.
19 CAULK ALL COUNTERTOP BACKSPLASHES TO WALL USING SILICONE
SEALANT.
20 ALL NEW INTERIOR FINISHES, INCLUDING FLOOR, WALL, AND CEILING
MATERIALS, SHALL BE IN ACCORDANCE WITH FLAME SPREAD AND SMOKE
DEVELOPMENT REQUIREMENTS, CHAPTER 8, CURRENT EDITION OF THE
INTERNATIONAL BUILDING CODE AND NFPA 101.
21 EXISTING CONDITIONS SHALL BE FIELD VERIFIED PRIOR TO BIDDING OR
BEGINNING OF WORK. ANY ERRORS OR OMISSIONS SHALL BE BROUGHT
TO THE ATTENTION OF THE ARCHITECT.
22 COVER ALL RETURN AIR AND EXHAUST GRILLES WITH FILTER MEDIA FOR
DURATION OF JOB AND CHANGE REGULARLY.
GENERAL NOTES
ACCESSORY MOUNTING HEIGHTS
UPUP
S S S
C-6121 C-6122 C-6123 C-6124
C-6118C-6119 C-6120
D-6024 D-6025
D-6035D-6036D-6037D-6038
D-6039
D-6040
D-6001
D-6022D-6034
D-6033
D-6002
D-6003
D-6004
D-6005
D-6006
D-6007 D-6008 D-6009
D-6011
D-6018
D-6017
D-6014
D-6021
D-6012
D-6032 D-6027
D-6029
D-6026 D-6013
C-6-C1
D-6-C4
D-6-C5
D-6-C3
D-6041
D-6-C1
D-6-C2
D-6020
D-6019
D-6010
D-6030
D-6031 D-6028
22'
6'38'
4'
22'
38'
9'
7'
38'
34'
4'
42'
32'
39'
20'
13'
23'
7'
16'
36'
23'
23'
7'
20'
EXAM/INFUSION SUITE
CODE LEGEND
REFERENCE CODES:
A. BUILDING OCCUPANCY CLASSIFCATION
1. Ambulatory Business (NFPA 101)
B. BUILDING CONSTRUCTION TYPE
1. Type II (222) -NFPA
C. BUILDING HEIGHT
1. > 4 stories allowed
a. Actual: 9 stories
D. FIRE SUPPRESSION SYSTEM
1. Fully automatic supervised fire sprinkler system is installed
E. OCCUPANCY LOAD
1. Ambulatory Business:1 Occupant per 100 sf
a. 10,770 sf/100 = 107 occupants
F. EXITING
1. Travel distance to an exit: 300 feet allowed
G. CORRIDORS
1. Deadend corridors shall not exceed 50 feet
a. All corridors within the project area are less than 50 feet to an exist or point where an occupant can travel two ways to an exit
2. Fire Rating: No requirements.
H. AREA CALCULATIONS
6th Floor Construction Area: 10,770 SF
SEMI RECESSED FIRE EXTINGUISHER
CABINET W/ FIRE EXTINGUISHER.
VERIFY FEC LOCATIONS AND QUANTITIES
W/ OWNER AND FIRE MARSHAL. SEE
DETAIL ON THIS SHEET.
10'
EXIT
TRAVEL DISTANCE
2 HOUR RATED FIRE BARRIER
SMOKE BARRIER
2 HOUR RATED AREA SEPARATION
1 HOUR RATED FIRE PARTITION
2012 IBC
2014 Indiana Building Code NFPA 101 Life Safety Code NFPA 10 Standard for Portable Fire Extinguishers NFPA 99 Health Care Facilities Code
LIFE SAFETY CODE
SEMI-RECESSED
FIRE CABINET
3 5/8" METAL STUD
SOUND
ATTENUATION
5/8" GYPSUM
WALLBOARD EACH SIDE
M A
X
T O
F E
C H
A N
D L E
FLOOR LINE
FULLY SPRINKLERED
o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Office of Construction and Facilities Management th re e e ig h th s in c h o n e fo o t
EXPAND SPECIALTY
CARE
SUBMISSIONS
REVISIONS
ARCHITECT/ENGINEERS:
USFin Development, LLC 1105 West Weir Street Litchfield, IL 62056
CONSULTANTS
7260 SHADELAND STATION
INDIANAPOLIS, IN 46256-3957
TEL 317.547.5580 FAX 317.543.0270
www.structurepoint.com
United States Department of Veterans Affairs R. L. Roudebush VAMC 1481 West 10th Street Indianapolis, Indiana 46202
65% DESIGN DEVELOPMENT 1-23-15
95% CONSTRUCTION DOCUMENTS 2-25-15
11FY14100% SUBMITTAL DOCUMENTS 5-29-15
BID DOCUMENTS 5-10-17
/8
/2
:1 :0
P
M C
R e v it \2
\L o c a l C o p ie s \2
V
A In d y O n c o lo g y C
E N
T R
A L R ff a c k e n th a l.
rv t
SIXTH FLOOR-LIFE SAFETY PLAN
05-10-17
V.A. 583-331
R. L. Roudebush VAMC, Indianapolis, IN
1-LS-001
FF APN
BIDDING DOCUMENTS
N
1/8" = 1'-0"
1-LS-001
1 SIXTH LEVEL LIFE SAFETY PLAN
6TH-LIFE SAFETY REFERENCE CODES
N
N
SIXTH FLOOR KEY PLAN
AREA 'A' AREA
'B'
TRUE NORTH
PLAN NORTH
FIRE EXT. CABINET
FIRE EXT. CABINET ELEVATION
1 Pharmacy Revisions 3-5-17