VA250-17-R-0594-024.pdf

PDF 15 MB Posted

Attached to
Expand Specialty Care Clinic 583-331
Solicitation number
VA25017R0594
Issued by

About this file

VA250-17-R-0594 Attachment 1. Bldg 1-Architectural-Drawings.pdf

View the file

Other files

File Type Posted
VA250-17-R-0594-00004000.docx DOCX document
VA250-17-R-0594-00004001.pdf PDF
VA250-17-R-0594-00003000.docx DOCX document
VA250-17-R-0594-00003001.pdf PDF
VA250-17-R-0594-00002006.pdf PDF
VA250-17-R-0594-00002011.pdf PDF
VA250-17-R-0594-00002013.pdf PDF
VA250-17-R-0594-00002007.pdf PDF
VA250-17-R-0594-00002001.doc DOC document
VA250-17-R-0594-00002003.pdf PDF
VA250-17-R-0594-00002000.docx DOCX document
VA250-17-R-0594-00002010.pdf PDF
VA250-17-R-0594-00002004.pdf PDF
VA250-17-R-0594-00002015.pdf PDF
VA250-17-R-0594-00002005.pdf PDF
VA250-17-R-0594-00002014.pdf PDF
VA250-17-R-0594-00002012.pdf PDF
VA250-17-R-0594-00002016.pdf PDF
VA250-17-R-0594-00002009.pdf PDF
VA250-17-R-0594-00002008.pdf PDF
VA250-17-R-0594-00002002.pdf PDF
VA250-17-R-0594-00001001.pdf PDF
VA250-17-R-0594-00001000.docx DOCX document
VA250-17-R-0594-00001002.pdf PDF
VA250-17-R-0594-036.docx DOCX document
VA250-17-R-0594-040.doc DOC document
VA250-17-R-0594-037.docx DOCX document
VA250-17-R-0594-033.pdf PDF
VA250-17-R-0594-026.pdf PDF
VA250-17-R-0594-031.pdf PDF
VA250-17-R-0594-034.pdf PDF
VA250-17-R-0594-032.pdf PDF
VA250-17-R-0594-027.pdf PDF
VA250-17-R-0594-043.pdf PDF
VA250-17-R-0594-042.docx DOCX document
VA250-17-R-0594-029.pdf PDF
VA250-17-R-0594-028.pdf PDF
VA250-17-R-0594-044.pdf PDF
VA250-17-R-0594-038.pdf PDF
VA250-17-R-0594-025.pdf PDF
VA250-17-R-0594-041.docx DOCX document
VA250-17-R-0594-039.pdf PDF
VA250-17-R-0594-035.pdf PDF
VA250-17-R-0594-030.pdf PDF
VA250-17-R-0594-000.docx DOCX document
Show all 45

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

6 45

10 10101010

1111111111

11 11 11 11 11

15 1616

15 18

1111111111

E X

T E

N T

S O

F W

O R

K

EXTENTS OF WORK

EXTENTS OF WORK

C-6122

C-6121

C6-29

8-6

C6-28

C-6123

C-6124

C-6120

C-6118

C-6119

C-6125

D-6030 D-6031

D-6032

D-6032 D-6033

D-6034D-6035D-6036D-6037D-6038

D-6039

C6-33

7-6

D-6001

D-6002

D-6003

D-6004

D-6005 D-6006

D-6007

D-6008

CG-31

C6-30

D-6009

D-6010

D-6011 D-6012

D-6013

D-6014

D-6015

D-6016

D-6017

D-6018

D-6019

D-6020

D-6021

P-9

P-8

D-6022

D-6023 D-6024

D-6025

D-6026

P-7

D-6028

D-6027

FULLY SPRINKLERED

o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Office of Construction and Facilities Management th re e e ig h th s in c h o n e fo o t

EXPAND SPECIALTY

CARE

SUBMISSIONS

REVISIONS

ARCHITECT/ENGINEERS:

USFin Development, LLC 1105 West Weir Street Litchfield, IL 62056

CONSULTANTS

7260 SHADELAND STATION

INDIANAPOLIS, IN 46256-3957

TEL 317.547.5580 FAX 317.543.0270

www.structurepoint.com

United States Department of Veterans Affairs R. L. Roudebush VAMC 1481 West 10th Street Indianapolis, Indiana 46202

65% DESIGN DEVELOPMENT 1-23-15

95% CONSTRUCTION DOCUMENTS 2-25-15

11FY14100% SUBMITTAL DOCUMENTS 5-29-15

BID DOCUMENTS 5-10-17

/8

/2

:1 :3

P

M C

R e v it \2

\L o c a l C o p ie s \2

V

A In d y O n c o lo g y C

E N

T R

A L R ff a c k e n th a l.

rv t

SIXTH FLOOR DEMOLITION PLAN

05-10-17

V.A. 583-331

R. L. Roudebush VAMC, Indianapolis, IN

1-AD-101

FF APN

BIDDING DOCUMENTS

N

1/8" = 1'-0"

1-AD-101

1 SIXTH FLOOR-DEMOLITION

1 REMOVE ACCORDIAN PARTITION & ASSOCIATED SUPPORT STRUCTURE COMPLETE. VERIFY ALL ITEMS TO

BE RELOCATED OR TURNED OVER TO OWNER

2 REMOVE FIRE EXTINGUISHER CABINET

3 FIRE EXTINGUISHER CABINET TO REMAIN. RE-PAINT OUTSIDE AND INSIDE AS LOCAL CODE PERMITS TO

MATCH NEW CABINETS

4 REMOVE BATHROOM ACCESSORIES, PARTITIONS AND GRAB BARS, VERIFY ALL ITEMS TO BE RELOCATED OR TURNED OVER TO OWNER. ITEMS TO BE TURNED OVER TO BE TAKEN TO DESIGNATED STORAGE AREA

5 REMOVE PLUMBING FIXTURES COMPLETE. REF. PLUMBING DEMOLITION DRAWINGS

6 REMOVE GLAZED CERAMIC WALL TILE. REPAIR OR REPLACE SUBSTRATE TO MATCH EXISTING ADJACENT THICKNESS. REMOVE GWB AS REQUIRED FOR BLOCKING AND INSULATION OF NEW FURNITURE SYSTEMS & EQUIPMENT. COORDINATE LOCATION OF NEW EQUIPMENT WITH ARCHITECTURAL & MEP DRAWINGS

7 REMOVE HANDRAILS & ALL OTHER EQUIPMENT ATTACHED TO WALL. REMOVE FURRING WHERE EXISTS DOWN TO ORIGINAL PARTITION STRUCTURE. REPAIR OR REPLACE GWB TO MATCH EXISTING ADJACENT THICKNESS. REMOVE GWB AS REQUIRED FOR BLOCKING AND INSULATION OF NEW FURNITURE SYSTEMS &

EQUIPMENT.

8 REMOVE DRINKING FOUNTAIN. REF PLUMBING DEMOLITION DRAWINGS

9 LOCATION OF EXISTING ACCESS PANEL. REF MEP DWGS

10 REMOVE & SALVAGE DEMOUNTABLE WALL SYSTEM/CUBICAL WALL SYSTEM AND TURN OVER TO OWNER

11 REMOVE LAMINATE WINDOW SILLS AT WINDOWS

12 REPLACE EXPANSION JOINT COVER WITH NEW

13 REMOVE CASEWORK COMPLETE

14 REMOVE GYPSUM BULKHEAD COMPLETE

15 HM FRAME & HARDWARE TO REMAIN. REPAINT DOOR PANEL AND FRAME.

16 NO DEMOLITION WORK TO BE DONE IN THIS SPACE

17 MED GAS SHUT-OFF TO BE RELOCATED. COORD W/ MEP DWGS

18 REPLACE DOOR PANELS & HARDWARE. FRAME TO REMAIN

19 REMOVE DUSTPROOF STRIKE IN FLOOR

20 REMOVE PLASTER & LATHE AT WINOW. REPLACE W/ WOOD BLOCKING & SOLID SURFACE SILL

21 INSTALL LOCKING HARDWARE WITH 7-PIN REMOVABLE CORE DURING CONSTRUCTION. DOOR TO REMAIN LOCKED FROM STAIRWELL SIDE TO PREVENT PUBLIC AND STAFF FROM ENTERING CONSTRUCTION AREA.

HARDWARE TO ALLOW FOR EGRESS INTO STAIRWELL AT ALL TIMES

DEMOLITION PLAN KEY NOTES ( )2

N

N

SIXTH FLOOR KEY PLAN

AREA 'A' AREA

'B'

TRUE NORTH

PLAN NORTH

A VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING WORK. NOTIFY THE ARCHITECT AND COR OF ANY

CONFLICTS PRIOR TO PROCEEDING WITH DEMOLITION.

B ALL FURNITURE, FURNISHINGS AND EQUIPMENT WILL BE REMOVED, RELOCATED AND/OR STORED BY VA

PERSONNEL UNLESS NOTED OTHERWISE.

C ALL ITEMS BEING REMOVED SHALL REMAIN THE PROPERTY OF THE VA MEDICAL CENTER UNTIL CONFIRMATION HAS BEEN MADE BY THE COR AS TO WHETHER THE VA WILL RETAIN SUCH ITEMS. ALL ITEMS NOT BEING RETAINED BY THE VA OR DESIGNATED ON THE DRAWINGS TO BE RELOCATED OR REINSTALLED

SHALL BE COMPLETELY REMOVED FROM THE SITE BY THE CONTRACTOR.

D THE DEMOLITION CONTRACTOR SHALL PROVIDE AND INSTALL ONE-HOUR FIRE-RATED TEMPORARY DUST PARTITIONS, 45 MINUTE FIRE-RATED DOORS, WALK-OFF MATS AND EQUIPMENT PROTECTION WHERE SHOWN ON THE DOCUMENTS OR IMPLIED BY THE WORK BEING PERFORMED. SUCH PROTECTION SHALL BE MAINTAINED AND REPAIRED PROMPTLY IF DAMAGED TO AVOID DUST INFILTRATION INTO ADJACENT AREAS.

PROVIDE HEPA FILTER FILTRATION AND NEGATIVE AIR MACHINES WITH MONITORING GAGES.

E COVER ALL ACTIVE RETURN AIR GRILLES AND EXHAUST GRILLES IN CONSTRUCTION AREA WITH FILTER MEDIA

AND CHANGE REGULARLY.

F REFER TO MECHANICAL, ELECTRICAL, FIRE PROTECTION, COMMUNICATION, AND PLUMBING DOCUMENTS FOR

RESPECTIVE DEMOLITION INFORMATION.

G REPAIR AND LEVEL FLOOR SLAB, WALLS AND/OR CEILINGS SUITABLE FOR NEW FINISHES WHERE DEMOLITION CAUSES OR EXPOSES DAMAGE TO THESE SURFACES. FLOOR LEVELING MAY REQUIRE GRINDING OF RAISED

AREAS OR FILLING LOW AREAS TO PROVIDE SUITABLE SURFACES FOR NEW MATERIIALS.

H REMOVE ALL REMAINING MISCELLANEOUS EQUIPMENT/ACCESSORIES ON WALLS AND CEILINGS IN AREA OF RENOVATION UNLESS NOTED OTHERWISE. VERIFY ITEMS TO BE RELOCATED OR TURNED OVER TO THE VA.

I FILL ALL FLOOR OPENINGS WITH APPROPRIATE FIRESTOPPING ASSEMBLIES WHERE PIPING, CONDUITS, DUCTS, AND OTHER ITEMS HAVE BEEN REMOVED. MAINTAIN TWO-HOUR FIRE RATING OF FLOOR ASSEMBLY.

J REPAIR/REPLACE COLUMN FIREPROOFING IF DAMAGED DURING DEMOLITION PROCESS.

K COORDINATE WORKING HOURS ALLOWED FOR DEMOLITION WITH VA COR AS INSTRUCTED IN THE GENERAL

REQUIREMENTS.

L AFTER REMOVAL OF EXISTING CHASES, VERIFY FLOOR PENETRATION CONDITION. FIRE STOP ALL PENETRATIONS THROUGH FLOOR TO COMPLY WITH A TWO-HOUR FIRE RATING OR IF NECESSARY, INSTALL A

TWO-HOUR FIRE RATED CHASE.

DEMOLITION PLAN GENERAL NOTES

TYPICAL DEMOLISHED ITEMS

1 REMOVE WALL COMPLETE. PATCH AND REPAIR CONCRETE SLAB WITH TOPPING MATERIAL FLUSH WITH ADJACENT FLOOR SLAB. ALSO PATCH AND REPAIR AT EXISTING WALL(S) (WHERE APPLICABLE) TO MATCH SURROUNDING FINISH AND MATERIALS, CUT OUT EXTERIOR MASONRY WALL AND TOOTH

IN NEW MASONRY AS REQUIRED

2 REMOVE DOOR, FRAME & HARDWARE. ALL CYLINDRICAL LEVER STYLE AND MORTISE TYPE

LATCHSETS, LOCKSETS, AND STRIKES SHALL BE TURNED OVER TO THE OWNER.

3 REMOVE FLOOR FINISH(ES) AND BASE TO CONCRETE. PREPARE FOR NEW FINISH. ALL ACM

FLOORING AND MASTIC SHALL BE REMOVED IN ACCORDANCE WITH THE ASBESTOS ABATEMENT

SPECIFICATIONS

4 REMOVE SUSPENDED ACOUSTICAL CEILING GRID & BOARD

DASHED ELEMENTS TO BE REMOVED PER NOTES BELOW & ON PLAN

NOTES COVER BOTH 6TH & 8TH FLOORS AND MAY NOT APPEAR ON THIS SHEET

Revision # Description Date

B2

B3

B6

B1 B1S

WALL PARTITION TYPE

P

LA

N V

IE

W

S E

C T

IO

N

V

IE

W S

E C

T

IO

N V

IE

W

REMARKS

REFER TO SCHEDULE BELOW FOR PARTITION WIDTH

NON-

RATED

B

METAL STUD FRAMING @ 16" O.C. MAX.

ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE

PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED - SEE SCHEDULE BELOW

METAL RUNNER

SEALANT AND BACKER ROD; BOTH SIDES, CONT.

ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS;

REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURANCE, LOCATION, AND

EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES

TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL

METAL RUNNER

LINE OF

STRUCTURE

UNDERSIDE

OF DECK

LINE OF

CEILING

STUD

WIDTH

PART.

WIDTH

FIRE

RATING

UL LISTING

WITH SOUND

ATTENUATION

DESIGNATION

NO SOUND

ATTENUATION

DESIGNATION

NA2 - 7/8"

3 - 3/4"

4 - 7/8"

7 - 1/4"6"

3 - 5/8"

2 - 1/2"

1 - 5/8"

STC:

NO SOUND

WITH SOUND

B2S

B3S

B6S

B8

9 - 1/4"8"

B8S

SEALANT AND BACKER ROD; BOTH SIDES, CONT.

NON-

RATED NA

NON-

RATED NA

NON-

RATED NA

NON-

RATED NA

F2

F3

F6

F1 F1S

WALL PARTITION TYPE

4"

P

LA

N V

IE

W

S E

C T

IO

N

V

IE

W S

E C

T

IO

N V

IE

W

REMARKS

NON-

RATED

NON-

RATED

NON-

RATED

REFER TO SCHEDULE BELOW FOR PARTITION WIDTH

NON-

RATED

F

METAL STUD FRAMING @ 16" O.C. MAX.

ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, ONE SIDE

PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED - SEE SCHEDULE BELOW

METAL RUNNER

SEALANT AND BACKER ROD; ONE SIDE, CONT.

ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS;

REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURANCE, LOCATION,

AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD

REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S

CLOSETS,TYPICAL.

METAL RUNNER

LINE OF

STRUCTURE

UNDERSIDE OF

DECK

LINE OF

CEILING

STUD

WIDTH

PART.

WIDTH

FIRE

RATING

UL LISTING

WITH SOUND

ATTENUATION

DESIGNATION

NO SOUND

ATTENUATION

DESIGNATION

NA

NA

NA

NA

2 - 1/4"

3 - 1/8"

4 - 1/4"

6 - 5/8"6"

3 - 5/8"

2 - 1/2"

1 - 5/8"

STC:

NO SOUND

WITH SOUND

F2S

F3S

F6S

NON-

RATED

NA2 5/8"2" Z

F2.Z

2" Z-CLIP

3 HOUR ASSEMBLY 1

2 HOUR ASSEMBLY 2

1 HOUR ASSEMBLY 3

SMOKE RATED ASSEMBLY 4

NON RATED ASSEMBLY 5

RATING PRIORITY

HIGHER PRIORITY PARTITION

GYPSUM BOARD CONTINUES

THROUGH STUD CAVITY OF

LOWER WALL

LOWER PRIORITY PARTITION

(LOWER NUMBER, HIGHER PRIORITY)

HIGHER PRIORITY

CEILING/ROOF ASSEMBLY

LOWER PRIORITY PARTITION

GYPSUM BOARD CONTINUES

PAST TOP OF LOWER WALL

C2

C3

C6

C1 C1S

WALL PARTITION TYPE

P

LA

N V

IE

W

S E

C T

IO

N

V

IE

W S

E C

T

IO

N V

IE

W

REMARKS

REFER TO SCHEDULE BELOW FOR PARTITION WIDTH

ONE

HOUR

C

METAL STUD FRAMING @ 16" O.C. MAX.

ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE.

PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED - SEE SCHEDULE BELOW

METAL RUNNER

RATED SEALANT AND BACKER ROD; BOTH SIDES, CONT.

ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS;

REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURANCE, LOCATION,

AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD

REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S

CLOSETS,TYPICAL.

METAL RUNNER

LINE OF

STRUCTURE

UNDERSIDE

OF DECK

LINE OF

CEILING

STUD

WIDTH

PART.

WIDTH

FIRE

RATING

UL LISTING

WITH SOUND

ATTENUATION

DESIGNATION

NO SOUND

ATTENUATION

DESIGNATION

UL Des U419 or U465

2 - 7/8"

3 - 3/4"

4 - 7/8"

7 - 1/4"6"

3 - 5/8"

2 - 1/2"

1 - 5/8"

STC:

NO SOUND

WITH SOUND

C2S

C3S

C6S

C8

9 - 1/4"8"

C8S

ONE

HOUR

ONE

HOUR

ONE

HOUR

ONE

HOUR

RATED SEALANT AND BACKER ROD; BOTH SIDES, CONT.

UL Des U419 or U465

UL Des U419 or U465

UL Des U419 or U465

UL Des U419 or U465

A2

A3

A6

A1 A1S

WALL PARTITION TYPE

4"

P

LA

N V

IE

W

S E

C T

IO

N

V

IE

W S

E C

T

IO

N V

IE

W

REMARKS

NON-

RATED

NON-

RATED

NON-

RATED

REFER TO SCHEDULE BELOW FOR PARTITION WIDTH

NON-

RATED

A

METAL STUD FRAMING @ 16" O.C. MAX.

ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE

PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED - SEE SCHEDULE BELOW

METAL RUNNER

SEALANT AND BACKER ROD; BOTH SIDES, CONT.

ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS;

REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURANCE, LOCATION, AND

EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES

TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL

METAL RUNNER

LINE OF

STRUCTURE

UNDERSIDE

OF DECK

LINE OF

CEILING

STUD

WIDTH

PART.

WIDTH

FIRE

RATING

UL LISTING

WITH SOUND

ATTENUATION

DESIGNATION

NO SOUND

ATTENUATION

DESIGNATION

NA

NA

NA

NA

2 - 7/8"

3 - 3/4"

4 - 7/8"

7 - 1/4"6"

3 - 5/8"

2 - 1/2"

1 - 5/8"

STC:

NO SOUND

WITH SOUND

A2S

A3S

A6S

A8

NON-

RATED

NA9 - 1/4"8"

A8S

G2

G3

G6

G1 G1S

WALL PARTITION TYPE

P

LA

N V

IE

W

S E

C T

IO

N

V

IE

W S

E C

T

IO

N V

IE

W

REMARKS

NON-

RATED

NON-

RATED

NON-

RATED

REFER TO SCHEDULE BELOW FOR PARTITION WIDTH

NON-

RATED

G

METAL STUD FRAMING @ 16" O.C. MAX.

ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, ONE SIDE

PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED - SEE SCHEDULE BELOW

METAL RUNNER

SEALANT AND BACKER ROD; ONE SIDE, CONT.

ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS;

REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURANCE, LOCATION,

AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD

REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S

CLOSETS,TYPICAL.

METAL RUNNER

LINE OF

STRUCTURE

UNDERSIDE OF

DECK

LINE OF

CEILING

STUD

WIDTH

PART.

WIDTH

FIRE

RATING

UL LISTING

WITH SOUND

ATTENUATION

DESIGNATION

NO SOUND

ATTENUATION

DESIGNATION

NA

NA

NA

NA

2 - 1/4"

3 - 1/8"

4 - 1/4"

6 - 5/8"6"

3 - 5/8"

2 - 1/2"

1 - 5/8"

STC:

NO SOUND

WITH SOUND

G2S

G3S

G6S

G8

NON-

RATED

NA8 - 5/8"8"

G8S

SEALANT AND BACKER ROD; ONE SIDE, CONT.

H2

H3

H6

H1 H1S

WALL PARTITION TYPE

P

LA

N V

IE

W

S E

C T

IO

N

V

IE

W S

E C

T

IO

N V

IE

W

REMARKS

REFER TO SCHEDULE BELOW FOR PARTITION WIDTH

NON-

RATED

H

METAL STUD FRAMING @ 16" O.C. MAX.

ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, PHARMACY SIDE

PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED - SEE SCHEDULE BELOW

METAL RUNNER

SEALANT AND BACKER ROD; BOTH SIDES, CONT.

ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS;

REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURANCE, LOCATION, AND

EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES

TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL

METAL RUNNER

LINE OF

STRUCTURE

UNDERSIDE

OF DECK

LINE OF

CEILING

STUD

WIDTH

PART.

WIDTH

FIRE

RATING

UL LISTING

WITH SOUND

ATTENUATION

DESIGNATION

NO SOUND

ATTENUATION

DESIGNATION

NA

6"

3 - 5/8"

2 - 1/2"

1 - 5/8"

STC:

NO SOUND

WITH SOUND

H2S

H3S

H6S

H8

8"

H8S

SEALANT AND BACKER ROD; BOTH SIDES, CONT.

NON-

RATED NA

NON-

RATED NA

NON-

RATED NA

NON-

RATED NA

ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, SIDE OPPOSITE PHARMACY

.048" HIGH STRENGTH, FIRE RESISTANT, CARBON STEEL MESH, SIDE OPPOSITE

PHARMACY

2 - 15/16"

3 - 13/16"

4 - 15/16"

7 - 5/16"

9 - 5/16"

I2

I3

I6

I1 I1S

WALL PARTITION TYPE

P

LA

N V

IE

W

S E

C T

IO

N

V

IE

W S

E C

T

IO

N V

IE

W

REMARKS

REFER TO SCHEDULE BELOW FOR PARTITION WIDTH

NON-

RATED

I

METAL STUD FRAMING @ 16" O.C. MAX.

PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED - SEE SCHEDULE BELOW

METAL RUNNER

SEALANT AND BACKER ROD; BOTH SIDES, CONT.

ADDITIONAL WALL FINISH (SHOWN DASHED) WHERE OCCURS; REFER TO FLOOR PLANS

AND ROOM FINISH SCHEDULE FOR OCCURANCE, LOCATION, AND EXTENT OF WALL

COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS

SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL

METAL RUNNER

LINE OF

STRUCTURE

UNDERSIDE

OF DECK

LINE OF

CEILING

STUD

WIDTH

PART.

WIDTH

FIRE

RATING

UL LISTING

WITH SOUND

ATTENUATION

DESIGNATION

NO SOUND

ATTENUATION

DESIGNATION

NA2 - 5/16"

3 - 3/16"

4 - 5/16"

6 - 11/16"6"

3 - 5/8"

2 - 1/2"

1 - 5/8"

STC:

NO SOUND

WITH SOUND

I2S

I3S

I6S

I8

8 - 11/16"8"

I8S

SEALANT AND BACKER ROD; BOTH SIDES, CONT.

NON-

RATED NA

NON-

RATED NA

NON-

RATED NA

NON-

RATED NA

ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD

.048" HIGH STRENGTH, FIRE RESISTANT, CARBON STEEL MESH

AK4

AK6

AK2 AK2S

WALL PARTITION TYPE

P

LA

N V

IE

W

S E

C T

IO

N

V

IE

W S

E C

T

IO

N V

IE

W

REMARKS

REFER TO SCHEDULE BELOW FOR PARTITION WIDTH

TWO

HOUR

AK

METAL C-H STUD FRAMING @ 24" O.C. MAX.

TWO (2) LAYERS 5/8" (TYPE-X) GYPSUM WALL BOARD, ONE SIDE

PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED - SEE SCHEDULE BELOW

METAL "J" RUNNER

RATED SEALANT AND BACKER ROD; BOTH SIDES, CONT.

METAL "J" RUNNER

LINE OF

STRUCTURE

UNDERSIDE

OF DECK

LINE OF

CEILING

STUD

WIDTH

PART.

WIDTH

FIRE

RATING

UL LISTING

WITH SOUND

ATTENUATION

DESIGNATION

NO SOUND

ATTENUATION

DESIGNATION

3 - 3/4"

5 - 1/4"

7 - 1/4"6"

4"

2 - 1/2"

STC:

NO SOUND

WITH SOUND

AK4S

AK6S

RATED SEALANT AND BACKER ROD; BOTH SIDES, CONT.

ONE LAYER 1" GYPSUM SHAFT WALL LINER PANEL

UL Des U415-B or U438

UL Des U415-B or U438

UL Des U415-B or U438

TWO

HOUR

TWO

HOUR

ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS;

REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURANCE, LOCATION, AND

EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES

TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL.

FULLY SPRINKLERED

o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Office of Construction and Facilities Management th re e e ig h th s in c h o n e fo o t

EXPAND SPECIALTY

CARE

SUBMISSIONS

REVISIONS

ARCHITECT/ENGINEERS:

USFin Development, LLC 1105 West Weir Street Litchfield, IL 62056

CONSULTANTS

7260 SHADELAND STATION

INDIANAPOLIS, IN 46256-3957

TEL 317.547.5580 FAX 317.543.0270

www.structurepoint.com

United States Department of Veterans Affairs R. L. Roudebush VAMC 1481 West 10th Street Indianapolis, Indiana 46202

65% DESIGN DEVELOPMENT 1-23-15

95% CONSTRUCTION DOCUMENTS 2-25-15

11FY14100% SUBMITTAL DOCUMENTS 5-29-15

BID DOCUMENTS 5-10-17

/8

/2

:1 :3

P

M C

R e v it \2

\L o c a l C o p ie s \2

V

A In d y O n c o lo g y C

E N

T R

A L R ff a c k e n th a l.

rv t

WALL TYPES & RATED PARTITIONS

05-10-17

V.A. 583-331

R. L. Roudebush VAMC, Indianapolis, IN

1-AS-001

FF APN

BIDDING DOCUMENTS

INTERIOR PARTITION GENERAL NOTES

RATED WALL PRIORITY

1 PARTITION SYMBOLS APPEAR ON LARGEST SCALE FLOOR PLAN PROVIDED FOR

AREA.

2 REFER TO FINISH PLANS FOR WALL FINISH, BASE, AND CEILING INFORMATION.

3 PROVIDE WATER-RESISTANT GYPSUM BOARD ON WALLS WITH OPERABLE PLUMBING

FIXTURES AND WITHIN 4'-0" OF DRINKING FOUNTAINS OR WATER COOLERS, U.N.O.

4 PROVIDE LATERAL BRACING FOR PARTITIONS WHICH EXTEND ABOVE CEILINGS.

5 PROVIDE FIRE RESISTIVE RATED GYPSUM WALL BOARD AT ALL RATED ASSEMBLIES

TO MEET ASSEMBLY REQUIREMENTS.

6 PROVIDE FIRE RESISTIVE JOINT SYSTEMS EQUAL TO WALL RATING AT ALL

PENETRATIONS AND AT HEAD/FLOOR INTERSECTIONS WITH RATED ASSEMBLIES.

7 PROVIDE ACOUSTICAL SEALANT AT WALL BASE, TOP, PENETRATIONS, AND

ADDITIONAL SPECIFIED SOUND ATTENUATION COMPONENTS AT SOUND RATED

WALLS.

8 PROVIDE SPECIFIED TILE BACKER BOARD AT ALL WALLS SCHEDULED TO HAVE

CERAMIC TILE.

9 STUD SPACING IS 16" O.C. MAX. U.N.O.

10 "LINE OF STRUCTURE" INDICATED FOR EACH PARTITION IS DIAGRAMMATIC ONLY

AND DOES NOT INDICATE EXACT CONSTRUCTION CONDITIONS OR GEOMETRY.

11 FIRE RESISTANCE RATED PARTITIONS SHALL USE RATED FIRE RESISTANT FILL

MATERIAL IN CONJUNCTION WITH AN APPROPRIATE RATED FIRESTOPPING SYTEM.

12 NON-RATED PARTITIONS SHALL USE ACOUSTICAL SEALANT.

13 REFER TO SPECIFICATIONS FOR MINIMUM STUD THICKNESS, MAXIMUM SPACING,

AND ALLOWABLE LIMITING HEIGHTS DEFLECTION CRITERIA FOR GYPSUM BOARD

ASSEMBLIES.

14 FOR PARTITIONS INDICATED TO RECEIVE SOUND ATTENUATION BLANKETS (SAB),

EXTEND SAFB TO FULL HEIGHT OF PARTITION U.N.O. FLOOR TRACK TO BE SET IN A

CONTINUOUS BED OF SEALANT.

15 ALTHOUGH WALL STUD SIZES ARE LISTED, FOR AREAS WHERE STUDS EXTEND TO

STRUCTURE ABOVE OR HIGH AREAS, CONTRACTOR TO VERIFY SIZE INDICATED IS

ADEQUATE FOR HEIGHT LISTED, PROVIDE ADEQUATE SIZE STEEL STUD FRAMING

AND NOTIFY ARCHITECT OF ANY DISCREPANCY PRIOR TO

FABRICATION/INSTALLATION.

D-6027

D-6013

C-6119C-6120 C-6118

C-6124C-6123C-6122C-6121

D-6037D-6038

D-6009D-6008D-6007

D-6006

D-6040

D-6039

D-6036

D-6029

D-6005

D-6004

D-6003

D-6002

D-6001

D-6011

D-6032

D-6033

D-6034

D-6018

D-6023

D-6014

D-6022

D-6021

D-6026

D-6019

D-6035 D-6025 D-6024

D-6-C4

D-6-C5

D-6-C1

D-6028

D-6030

D-6020

D-6010

D-6017

D-6012

D-6041

/1 1-AS-102B

/1 1-AS-102A

D-6-C2

D-6031

FULLY SPRINKLERED

o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Office of Construction and Facilities Management th re e e ig h th s in c h o n e fo o t

EXPAND SPECIALTY

CARE

SUBMISSIONS

REVISIONS

ARCHITECT/ENGINEERS:

USFin Development, LLC 1105 West Weir Street Litchfield, IL 62056

CONSULTANTS

7260 SHADELAND STATION

INDIANAPOLIS, IN 46256-3957

TEL 317.547.5580 FAX 317.543.0270

www.structurepoint.com

United States Department of Veterans Affairs R. L. Roudebush VAMC 1481 West 10th Street Indianapolis, Indiana 46202

65% DESIGN DEVELOPMENT 1-23-15

95% CONSTRUCTION DOCUMENTS 2-25-15

11FY14100% SUBMITTAL DOCUMENTS 5-29-15

BID DOCUMENTS 5-10-17

/8

/2

:1 :3

P

M C

R e v it \2

\L o c a l C o p ie s \2

V

A In d y O n c o lo g y C

E N

T R

A L R ff a c k e n th a l.

rv t

SIXTH FLOOR-OVERALL

05-10-17

V.A. 583-331

R. L. Roudebush VAMC, Indianapolis, IN

1-AS-101

FF APN

BIDDING DOCUMENTS

N

1/8" = 1'-0"

1-AS-101

1 SIXTH LEVEL FLOOR PLAN

GENERAL PLAN NOTES, ALL CONTRACTORS

GENERAL CONSTRUCTION NOTES

N

N

SIXTH FLOOR KEY PLAN

AREA 'A' AREA

'B'

TRUE NORTH

PLAN NORTH

A ALL ITEMS NOT SYMBOLIZED OR NOTED ARE EXISTING TO REMAIN.

B CUTTING AND PATCHING: ALL OPENINGS REQUIRED IN NEW CONSTRUCTION FOR

DUCTWORK, CONDUIT, ETC. SHALL BE BY G.C.

C UNLESS OTHERWISE NOTED, ALL OPENINGS AND PATCH WORK REQUIRED IN

EXISTING WALLS AND/OR FLOORS. FOR DUCTWORK, CONDUIT AND OTHER

PENETRATIONS SHALL BE BY RESPECTIVE MECHANICAL AND ELECTRICAL

CONTRACTORS. MAINTAIN EXISTING MATERIAL, FINISH AND FIRE RATING AT WALLS

TO BE PATCHED. COORDINATE WORK WITH G.C.

D ANY WOOD SHALL BE FIRE RETARDANT OR NON-FIRE RETARDANT PAINTED WITH

INTUMESCENT PAINT.

G1 PROVIDE LATEX UNDERLAYMENT AT ALL DEPRESSIONS IN EXISTING FLOOR SLAB AND

FLUSH WITH TOP OF EXISTING ADJACENT FLOOR.

G2 DISTANCE FROM EDGE OF DOOR JAMB AT HINGE SIDE TO FACE OF ADJACENT WALL SHALL

BE 4" UNLESS OTHERWISE NOTED.

G3 PROVIDE WALL BLOCKING AS REQUIRED FOR SUPPLIED FURNITURE SYSTEM.

COORDINATE W/ OWNER'S SUPPLIER.

1 Pharmacy Revisions 3-5-17

ELECTRICAL

ROOM

D-6027

SOILED

UTILITY

D-6013

SOCIAL

WORKERS/

DIETICIAN

C-6120

PATIENT

NAVIGATION

C-6121

EXAM

3/BD

D-6037

EXAM

4/BD

D-6038

EXAM 12

D-6009

EXAM 11

D-6008

EXAM 10

D-6007

EXAM 9 /

SPECIALTY

PROCEDURE

D-6006

S.U.

D-6040

HAC

D-6039

EXAM

2/BD

D-6036

PATIENT

TOILET

D-6029

EXAM 8

D-6005

EXAM 7

D-6004

EXAM 6

D-6003

EXAM 5

D-6002

C.U.

D-6001

PRIVATE

INFUSION

D-6011

EXAM 13/

TELEHEALTH

D-6032

EXAM 14

D-6033

EXAM 15

D-6034

MED PREP

D-6018

C.U.

D-6017

UNISEX

TOILET

D-6023

PATIENT

TOILET

D-6014

WAITING-PRIVATE

D-6022

/1 1-AS-102B

/1 1-AS-102B

025A

025B

EXAM

1/BD

D-6035

CHECK-IN/OUT

D-6025

WAITING-

GENERAL

D-6024

F1 F1

10' - 6 5/8" 10' - 7 1/4" 10' - 7 1/4" 10' - 4 7/8" 26' - 8 3/8"

B3S

B3S

B3S

B3S

B3SB3SB3SB3S

5' - 4 7/8" 5' - 4 7/8" 5' - 4 7/8" 5' - 2 7/8"

/8

1'

1/

B3S

F3SF3S

F3S

CORRIDOR

D-6-C3

F .O

.F

7'

1"

A3S

48" A.F.F.

A3S

48" A.F.F.

F3S

B3S

010C

035036037038

B3S

B3S

B3S

F1S

F3S

B6S

B3S

B6S

B6S

B3SB3S

B3S

B3S

B3S

F1

AK4S

AK4S

B3S

5'

/4

5'

/8

/2

6' - 5 3/8" 5' - 9" 9' - 5 3/4" 12' - 4 1/4"

5' - 1 3/8"

6'

/8

7'

/8

/8

/4

/8

/4

5'

/8

/8

AK4S

F1

B3S

B6S

B3S

B6S

B3S

B6S

B3S

B3S

B3S

B6S

B3S

B6S

B3S

B3S

F1

F1S

F3S

F3S

F1

F3S

B6S B6S

B6S

009008007

B3S

B3S

O.I.T./BIOMED

D-6021

ELEV.

LOBBY

D-6-C5

ELECTRICAL

ROOM

D-6026

PRIVATE

INFUSION

D-6012

F3S

B6S

B3S

B6S

F3S

F3S

B3S

B3S

HAC

D-6019

NURSE

STATION

D-6016

B3S

F1

F1

H6S

F3S

H3S

I3S

I3S

B3S

B3S

B3S

F1 F1

F1

H6S

H3S

G3S

G3S

F1

F1

H3S

F1

F6S

F1

CORRIDOR

D-6-C2

CORRIDOR

D-6-C1

CORRIDOR

D-6-C4

F3S

F3S

F3S F3

INFUSION

BAYS

D-6010

INFUSION

BAYS

D-6010

B3S

F1 F1

.0

110.00°

160.00°

110.00°

I3S

/8

/4

/8

8'

1/ 8"

/8

36' - 4 1/4"

F2.Z F2.Z

3' - 8 1/2" 8' - 11 13/16" 4' - 11 1/16" 3' - 0" 4' - 10 15/16" 8' - 11 7/8" 1' - 10 1/8"

9'

/8

SF1

B3S

6" 5' - 4 1/8"

F2S

A3S

F3S

3' - 1 1/2"

97.00°

B3S

0287'

/8

2'

/8

6'

7/ 8"

/4

B3S

B3S

3'

1/

6' - 8 1/2"

12' - 3 1/4" 6' - 10 7/8" 2' - 4 5/8" 12' - 5" 11' - 0 1/8"

CASE

MANAGER

D-6028

CHARTING

ROOM

D-6030

B6S

F1B3S

B3S

030A

030B

7'

1'

7/ 8"

1-AS-301

1-AS-301

1-AS-301

2'

/4

4' - 10 3/4"

5'

/4

F.O.

6' - 6"

F2.Z

F2.Z

F2.Z

F2.Z

F2.Z

F2.Z

F2.Z

B3SF3S

F2.Z

F2.Z

F2.Z

F3S

F3

10' - 4 5/8" 10' - 4 7/8" 10' - 7 1/4" 10' - 7 1/4" 4' - 0 5/8"

9' - 1 1/2"

PATIENT

TOILET

D-6031

B3S

160.00°

010A

2'

2' - 0"

B6S

B3S

B3S

B3S

SF2

6' - 10 7/8" 19' - 11 7/8" 3' - 7 1/8" 6' - 6 7/16"

9' - 11 7/8"

9' - 4 3/8"

F2.Z

F2.ZF2.ZF2.Z

19' - 6 3/8"

7' - 0 1/16"

15' - 6 15/16"

11 9/16"

7' - 8 5/8"

4' - 1 3/4"

6' - 3 5/8"

4' - 6 1/8"

4' - 8 1/2"

3' - 9 5/8"

8' - 8 1/2"

4' - 1 11/16" 2' - 2 7/8"

3' - 0"

5' - 7 3/8"

21' - 3 5/8"

3' - 7 3/4"

2' - 8 3/8"

6' - 5 5/8"

6' - 9 3/8"

7' - 3 5/8"

2'

/4

10' - 4 5/8"

3' - 9 1/4"

3' - 7 5/16"

8' - 0 7/8"

8' - 9 9/16"

6 5/8"

8' - 0 1/2"

4' - 2 5/8"

3' - 4"

6' - 1 7/8"

5' - 5 5/8"

G3S

G3S

G3S

1' - 3 3/8"7' - 6 1/2"

5' - 10 13/16" 11 5/8"

7'

5' - 9"

5' - 1 5/8"

1-AS-301

1-AS-501

1 1-AS-501

1-AS-501

PHARMACY-ORAL

CHEMO

D-6020

HEALTH

TECH

STATION

D-6041

SCALES

D-6-C1.A

W.C.

ALCOVE

D-6-C1.B

SCALE

D-6010.B

W.C.

ALCOVE

D-6010.C

W.C.

ALCOVE

D-6010.D

NOURISHMENT

CENTER

D-6-C4.A

DRINKING

FOUNTAIN

D-6-C4.B

9' - 0 1/4"

010B

C. B. X. W. V.

6.

5.

4.

3.

2.

1.

A. Y.Z. U.

F1

6"

4'

H3S

H3SH3S

2' - 6 7/8"

1'

5/ 8"

/8

6-C3

EX02

EX06

EX05

EX04

B3S

2'

/8

2'

1/ 4"

3'

1-AS-301

3' - 0"

W1

W1

2' - 7 1/8"

2' - 8 1/4"

7' - 2 7/8"

8' - 7 3/16"

.0

3' - 5 1/4"

8' - 3 3/16"

.6

5°

14 14

14 14 14 14

1-AS-501

F3S

B3S

A3S

6' - 4"7' - 1 5/8"

6"

F6S

3'

6-C2

3' - 6"

F6S

F6S

F6S

7'

/8

6'

0"

3'

/4

6' - 7 1/8"

1' - 8 5/8"

5' - 7"

9' - 0 1/4"

3' - 5 1/2"

TYP

TYP

7' - 1 1/4"

7' - 6 5/8"

9' - 6" F3S

3' - 3"

5' - 6 5/8"

B3S

B3S

F3S

F3S

F3S

B3S

F3S

PHARMACY

NON HD

PREP

STERILE

D-6015

15A

PHARMACY

HD PREP

STERILE

D-6015A

3' - 0"

6' - 3 1/4"

1' - 4"

3 5/8"

SIM.

FULLY SPRINKLERED

o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Office of Construction and Facilities Management th re e e ig h th s in c h o n e fo o t

EXPAND SPECIALTY

CARE

SUBMISSIONS

REVISIONS

ARCHITECT/ENGINEERS:

USFin Development, LLC 1105 West Weir Street Litchfield, IL 62056

CONSULTANTS

7260 SHADELAND STATION

INDIANAPOLIS, IN 46256-3957

TEL 317.547.5580 FAX 317.543.0270

www.structurepoint.com

United States Department of Veterans Affairs R. L. Roudebush VAMC 1481 West 10th Street Indianapolis, Indiana 46202

65% DESIGN DEVELOPMENT 1-23-15

95% CONSTRUCTION DOCUMENTS 2-25-15

11FY14100% SUBMITTAL DOCUMENTS 5-29-15

BID DOCUMENTS 5-10-17

/8

/2

:1 :4

P

M C

R e v it \2

\L o c a l C o p ie s \2

V

A In d y O n c o lo g y C

E N

T R

A L R ff a c k e n th a l.

rv t

SIXTH FLOOR-AREA 'A'

05-10-17

V.A. 583-331

R. L. Roudebush VAMC, Indianapolis, IN

1-AS-102A

FF APN

BIDDING DOCUMENTS

N

1/4" = 1'-0"

1-AS-102A

1 6TH FLOOR-AREA 'A'

N

N

SIXTH FLOOR KEY PLAN

AREA 'A' AREA

'B'

TRUE NORTH

PLAN NORTH

1 REPLACE EXPANSION JOINT COVER WITH NEW

2 FILL EXISTING OPENING WITH METAL STUD & GYPSUM BOARD TO

MATCH EXISTING WALL THICKNESS

3 SOUND ATTENUATING ACCORDIAN ROOM PARTITION

4 PLANT LEDGE

5 FIRE EXTINGUISHER CABINET - REF DETAILS ON LIFE SAFETY DWGS

6 DRINKING FOUNTAINS - REF PLUMBING DWGS

7 DASHED LINE INDICATES MAX LIMITS OF PATIENT LIFT LOCATION - REF

RCP

8 MOP SERVICE BASIN - REF PLUMBING DWGS

9 APPLY OPAQUE FILM TO WINDOW GLAZING

10 PASS-THRU WINDOW. SEE WINDOW ELEVATION FOR TYPE &

DIMENSIONS ON SHEET 1-AS-601

11 EYE WASH - COORD PLUMBING DWGS

12 ADHERE 1/2" GYPSUM BOARD TO EXISTING WALL. PROVIDE FURRING

AS REQUIRED TO MAKE FLUSH WITH ADJACENT WALL.

13 WALL MOUNTED BLOW-OUT SERVICE SINK

14 CUBICLE CURTAIN TRACK FLUSH W/ CEILING- SEE SHEET 1-AS-501

15 CUBICLE CURTAIN TRACK HUNG BELOW CEILING- SEE SHEET 1-AS-501

16 MED GAS ZONE BOX-COORD W/ MEP DRWGS

FLOOR PLAN KEY NOTES ( )2

FLOOR PLAN GENERAL NOTES

A WALL TAGS (ex F3S) REFER TO WALL TYPES ON SHEET 1-AS-001

B DIMENSIONS OF RADIUSED WALLS ON SHEETS 1-AS-111, 112.

DIMENSIONS SIM. TO BULKHEAD ABOVE

NOTE: REFERENCE 1-AS-112 FOR WALL

RADIUS DIMENSIONS

NOTES COVER BOTH 6TH & 8TH FLOORS AND MAY NOT APPEAR ON THIS SHEET

CLINICAL

MANAGER

C-6119

SOCIAL

WORKERS/

DIETICIAN

C-6120

STAFF

LOUNGE

C-6118

PATIENT

EDUCATION

C-6124

PATIENT

EDUCATION

C-6123

ONCOLOGY

COORDINATION

C-6122

PATIENT

NAVIGATION

C-6121

/1 1-AS-102A

/1 1-AS-102A

F3S

F3S

3'

/8

F3SF1

042043

044 045

F3SF1

8' - 11 3/4" 10' - 8 1/4" 15' - 10 1/2"

1' - 11 1/4"

CORRIDOR

C-6-C1

B3S

B3S

B3S B3S

8' - 3 3/16" 9' - 8 11/16" 10' - 2 1/8" 11' - 3 1/8"

F1

F3S

F1

F1

1' - 10 1/8"

1-AS-501

Sim

F .O

.F

0"

V. U. T.

F1

12 12

12 12

EX02

F3S

6-C1

CLR

7 1/2"

/2

8'

/8

/8

F .O

.F

7'

3/ 4"

TYP

F2.ZF2.Z F2.Z

F2.Z

F2.Z

1-AS-301

Sim

V.

5.

4.

U.

V .I.

F

2'

F .O

.F

D -7

1-AS-501

Sim

DOOR SET IN

NEW 'A6S' WALL

FULLY SPRINKLERED

o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Office of Construction and Facilities Management th re e e ig h th s in c h o n e fo o t

EXPAND SPECIALTY

CARE

SUBMISSIONS

REVISIONS

ARCHITECT/ENGINEERS:

USFin Development, LLC 1105 West Weir Street Litchfield, IL 62056

CONSULTANTS

7260 SHADELAND STATION

INDIANAPOLIS, IN 46256-3957

TEL 317.547.5580 FAX 317.543.0270

www.structurepoint.com

United States Department of Veterans Affairs R. L. Roudebush VAMC 1481 West 10th Street Indianapolis, Indiana 46202

65% DESIGN DEVELOPMENT 1-23-15

95% CONSTRUCTION DOCUMENTS 2-25-15

11FY14100% SUBMITTAL DOCUMENTS 5-29-15

BID DOCUMENTS 5-10-17

/8

/2

:1 :4

P

M C

R e v it \2

\L o c a l C o p ie s \2

V

A In d y O n c o lo g y C

E N

T R

A L R ff a c k e n th a l.

rv t

SIXTH FLOOR-AREA 'B', 7TH FLOOR

WORK

05-10-17

V.A. 583-331

R. L. Roudebush VAMC, Indianapolis, IN

1-AS-102B

FF APN

BIDDING DOCUMENTS

N

1/4" = 1'-0"

1-AS-102B

1 6TH FLOOR-AREA 'B'

N

N

SIXTH FLOOR KEY PLAN

AREA 'A' AREA

'B'

TRUE NORTH

PLAN NORTH

1 REPLACE EXPANSION JOINT COVER WITH NEW

2 FILL EXISTING OPENING WITH METAL STUD & GYPSUM BOARD TO

MATCH EXISTING WALL THICKNESS

3 SOUND ATTENUATING ACCORDIAN ROOM PARTITION

4 PLANT LEDGE

5 FIRE EXTINGUISHER CABINET - REF DETAILS ON LIFE SAFETY DWGS

6 DRINKING FOUNTAINS - REF PLUMBING DWGS

7 DASHED LINE INDICATES MAX LIMITS OF PATIENT LIFT LOCATION - REF

RCP

8 MOP SERVICE BASIN - REF PLUMBING DWGS

9 APPLY OPAQUE FILM TO WINDOW GLAZING

10 PASS-THRU WINDOW. SEE WINDOW ELEVATION FOR TYPE &

DIMENSIONS ON SHEET 1-AS-601

11 EYE WASH - COORD PLUMBING DWGS

12 ADHERE 1/2" GYPSUM BOARD TO EXISTING WALL. PROVIDE FURRING

AS REQUIRED TO MAKE FLUSH WITH ADJACENT WALL.

13 WALL MOUNTED BLOW-OUT SERVICE SINK

14 CUBICLE CURTAIN TRACK FLUSH W/ CEILING- SEE SHEET 1-AS-501

15 CUBICLE CURTAIN TRACK HUNG BELOW CEILING- SEE SHEET 1-AS-501

16 MED GAS ZONE BOX-COORD W/ MEP DRWGS

FLOOR PLAN KEY NOTES ( )2FLOOR PLAN GENERAL NOTES

A WALL TAGS (ex F3S) REFER TO WALL TYPES ON SHEET 1-AS-001

B DIMENSIONS OF RADIUSED WALLS ON SHEETS 1-AS-111, 112.

DIMENSIONS SIM. TO BULKHEAD ABOVE

N

1/4" = 1'-0"

1-AS-102B

2 7TH FLOOR-MONITORING PANEL

DOOR AND FRAME SCHEDULE-7TH FLOOR

MARK LOCATION

DOOR SIZE DOOR FRAME

HARDWARE FIRE RATING COMMENTSWIDTH HEIGHT MATERIAL TYPE MATERIAL TYPE JAMB HEAD

201 MONITORING PANEL 2' - 2" 7' - 0" WD D1 HM F1 J3 H3

NOTES COVER BOTH 6TH & 8TH FLOORS AND MAY NOT APPEAR ON THIS SHEET

OS

W

EXAM 4/BD

D-6038

EXAM 3/BD

D-6037

EXAM 2/BD

D-6036

EXAM 1/BD

D-6035

CHECK-IN/OUT

D-6025

WAITING-

GENERAL

D-6024

SOCIAL

WORKERS/

DIETICIAN

C-6120

CLINICAL

MANAGER

C-6119

STAFF

LOUNGE

C-6118

PATIENT

EDUCATION

C-6124

PATIENT

EDUCATION

C-6123

ONCOLOGY

COORDINATION

C-6122

PATIENT

NAVIGATION

C-6121

HAC

D-6039

S.U.

D-6040

C.U.

D-6001

HEALTH

TECH

STATION

D-6041

EXAM 5

D-6002

EXAM 6

D-6003

EXAM 13/

TELEHEALTH

D-6032

EXAM 14

D-6033

EXAM 15

D-6034

8' - 0" 8' - 0"

8' - 2"

8' - 0"8' - 0" 8' - 0"

8' - 0"

8' - 0"8' - 0" 8' - 0"8' - 0"8' - 0"

8' - 0"

8' - 0"

8' - 0"

8' - 0"

8' - 0"

8' - 0"

8' - 0" 8' - 0"

8' - 0"

8' - 0"

8' - 0"

8' - 0"

8' - 2"

7' - 8"

7' - 8"

7' - 8"

8' - 0"

8' - 0"

8' - 0"

8' - 0" 8' - 0" 8' - 0"

8' - 0"

8' - 0"

8' - 2"

8' - 6"

8' - 6"

8' - 2" 8' - 6"

8' - 2"

8' - 6"

8' - 2"

8' - 6"

8' - 2"

7' - 8" 7' - 8"

8' - 2"

8' - 0"

8' - 0"

8' - 0"

7' - 10"

8' - 0"

8' - 0"

8' - 0"

8' - 0"

8' - 0"

8' - 0"

8' - 0"

CASE

MANAGER

D-6028

CHARTING

ROOM

D-6030

9' - 0"

8' - 0"

8' - 0"

7' - 1"

7' - 1"

7' - 1"

7' - 1"

7' - 1"

7' - 1"

7' - 1" 7' - 10"

7' - 10"

7' - 8"

7' - 8"

1-AS-501

Sim

1-AS-501

Sim

7' - 10"

1-AS-501

Sim

5 555

5 5 5 5

1-AS-111

1-AS-111

8' - 2"

8' - 6"1

PATIENT

TOILET

D-6031

CORRIDOR

D-6-C4

ELEV. LOBBY

D-6-C5

O.I.T./BIOMED

D-6021

WAITING-PRIVATE

D-6022

CORRIDOR

D-6-C3

UNISEX

TOILET

D-6023

EXAM 9 /

SPECIALTY

PROCEDURE

D-6006

EXAM 10

D-6007

EXAM 11

D-6008

EXAM 12

D-6009

PRIVATE

INFUSION 1

D-6011

CORRIDOR

D-6-C2

INFUSION

BAYS

D-6010

NURSE

STATION

D-6016

HAC

D-6019

MED PREP

D-6018

C.U.

D-6017

8' - 0"

PHARMACY-ORAL

CHEMO

D-6020

PATIENT

TOILET

D-6014

PRIVATE

INFUSION 2

D-6012

1-AS-301

Sim

T Y

P

.5

8' - 2" 8' - 6"

8' - 2"

8' - 6"

8' - 2"

8' - 6"

8' - 2"

8' - 2"

8' - 6"

8' - 2"

8' - 6"

/8

11' - 7 13/16"

110.00°

FLUSH WITH WALL ANGLE

.0

8' - 6"

8' - 2" 8' - 2"

R 16' - 6"

R 19' - 4"

R

' - 0"

R 26' - 0"

F .O

.F

/8

F.O.F.

11' - 7 13/16"

R 44' - 0"

R

1'

0" R

' - 0

R

' - 4

R

' - 9

R

R 8' - 6"

R

7' - 10 1/8"

7'

3/ 8"

2'

/8

R 18' - 3"

2' - 7 1/2"

10' - 0"

1' - 1"

2' - 7"

5' - 4"

PRIVATE

INFUSION

D-6011

DASHED LINE

INDICATES MAX LIMITS

OF PATIENT LIFT

LOCATION

1' - 0" 8' - 6" 6"

2'

5'

EXAM 9 /

SPECIALTY

PROCEDURE

D-6006

DASHED LINE

INDICATES MAX LIMITS

OF PATIENT LIFT

LOCATION

FULLY SPRINKLERED

o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Office of Construction and Facilities Management th re e e ig h th s in c h o n e fo o t

EXPAND SPECIALTY

CARE

SUBMISSIONS

REVISIONS

ARCHITECT/ENGINEERS:

USFin Development, LLC 1105 West Weir Street Litchfield, IL 62056

CONSULTANTS

7260 SHADELAND STATION

INDIANAPOLIS, IN 46256-3957

TEL 317.547.5580 FAX 317.543.0270

www.structurepoint.com

United States Department of Veterans Affairs R. L. Roudebush VAMC 1481 West 10th Street Indianapolis, Indiana 46202

65% DESIGN DEVELOPMENT 1-23-15

95% CONSTRUCTION DOCUMENTS 2-25-15

11FY14100% SUBMITTAL DOCUMENTS 5-29-15

BID DOCUMENTS 5-10-17

/8

/2

:1 :4

P

M C

R e v it \2

\L o c a l C o p ie s \2

V

A In d y O n c o lo g y C

E N

T R

A L R ff a c k e n th a l.

rv t

SIXTH FLOOR-REFLECTED CEILING

PLAN

05-10-17

V.A. 583-331

R. L. Roudebush VAMC, Indianapolis, IN

1-AS-111

FF APN

BIDDING DOCUMENTS

N

1/8" = 1'-0"

1-AS-111

1 SIXTH FLOOR-REFLECTED CEILING PLAN

REFLECTED CEILING KEY NOTES ( )1

A ALL NEW CEILIING GRID IS EQUAL/EQUAL

WHERE BOUNDED BY NEW ROOM UNLESS

NOTED OTHERWISE

B ALIGN NEW CEILING GRID WITH EXISTING

WHERE EXTENDED IN EXISTING ROOM

C REFERENCE SHEETS 1-MI-001 & 1-E-001 FOR

MECHANICAL & ELECTRICAL SYMBOLS

GENERAL REFLECTED CEILING PLAN NOTES

N

N

SIXTH FLOOR KEY PLAN

AREA 'A' AREA

'B'

TRUE NORTH

PLAN NORTH

1 GYPSUM BOARD BULKHEAD

2 LINEAR LIGHT - COORD W/ ELECTRICAL DWGS

3 METAL TRIM BY CEILING MANUFACTURER

4 SUSPENDED CUBICLE CURTAIN TRACK - SEE SHEET 1-AS-501

5 FLUSH CUBICLE CURTAIN TRACK - SEE SHEET 1-AS-501

6 TURN UP CEILING TO EXPANSION JOINT COVER

7 PATIENT LIFT - TRACK, BRACING, HANGERS AND ALL CONNECTIONS

TO BUILDING STRUCTURE TO BE PROVIDED BY MANUFACTURER.

N

1/8" = 1'-0"

1-AS-111

2 SIXTH FLOOR-CEILING RADIAL DIMENSIONS

1/16" = 1'-0"

1-AS-111

3 SIXTH FLOOR-CEILING RADIAL DIMENSIONS

1/16" = 1'-0"

1-AS-111

4 SIXTH FLOOR-CEILING RADIAL DIMENSIONS

- ALL DIMENSIONS TO FACE OF FINISH

- RADIUS OF WALLS BELOW TO MATCH

DIMENSIONED RADIUS OF BULKHEADS

ALL DIMENSIONS TO FACE OF FINISH

NOTES COVER BOTH 6TH & 8TH FLOORS AND MAY NOT APPEAR ON THIS SHEET

- ALL DIMENSIONS TO FACE OF FINISH

- RADIUS OF WALLS BELOW TO MATCH

DIMENSIONED RADIUS OF BULKHEADS

N

1/4" = 1'-0"

1-AS-111

6 PATIENT LIFT-PRIVATE INFUSION

N

1/4" = 1'-0"

1-AS-111

5 PATIENT LIFT-SPECIALTY PROCEDURE

SIXTH_LEVEL

158' - 5 1/4"

BULKHEAD FLUSH W/

COLUMN WRAP

BEYOND

3 5/8" METAL STUD @ 16" O.C. W/

SOUND ATTENUATING INSULATION

BOTTOM OF SLAB

ACCOUSTICAL CEILING

5/8" GYPSUM WALLBOARD

5/8" GYPSUM WALLBOARD ON

2" Z-CHANNEL FURRING @

16" OC.

REMOVE EXISTING PL.

LAMINATE SILL AND INSTALL

NEW 1/2" SOLID SURFACE SILL

W/ BLOCKING

EXISTING WINDOW

1/2"

CLNG HEIGHT

REF RCP

R 1

4"

MANUFACTURED COLUMN WRAP -

REF INTERIOR FINISHES

EXISTING CONCRETE COLUMN

ATTACH TO STRUCTURAL

COLUMN PER MFG

DETAILS

SIXTH_LEVEL

158' - 5 1/4"

SIXTH_LEVEL

158' - 5 1/4"

VARIES

1/2"

5/8" GYPSUM WALLBOARD 3

5/8" METAL STUDS @ 16" OC.

REMOVE EXISTING PL. LAMINATE

SILL AND INSTALL NEW 1/2"SOLID

SURFACE SILL OVER 1/2" WOOD

SHEATHING OVER 3 5/8" METAL

STUDS @ 16" O.C.

EXISTING WINDOW

8'-2"

METAL ACCORDION CEILING TRACK

METAL ACCORDION DOOR TRACK

C8x11.5 STEEL CHANNEL

3"x3"x3/16" STEEL ANGLES

@ 48" O.C. MAX. - WELD

TO ANGLES ABOVE

ACOUSTICAL BOARD

CEILING TILE

8"x3/16"CONT. STEEL PLATE

THREADED ROD; SIZE AND SPACING IN ACCORDANCE

WITH ACCORDION DOOR MANUFACTURER

4"x4"x1/4" STEEL ANGLE, 16" LENGTH -

EPOXY EXPANSION ANCHORED INTO

EXISTING SLAB

3"x3"x3/16

" STEEL ANGLE

DIAGONAL BRACING @ 48"

O.C. MAX. - WELD TO

SUPPORT ANGLES

ACCORDION DOOR

EXISTING SLAB TO REMAIN

1/2

" DIAMETER EXPANSION ANCHOR W/ 4"

MIN. EMBED. HILTI KWIK BOLT TZ,

SIMPSON STRONGBOLT, POWERS

POWER-STUD+SD2 OR ARCHITECT

APPROVED EQUIVALENT

4"x4"x1/4

" STEEL ANGLE, 16" LENGTH -

EPOXY EXPANSION ANCHORED INTO

EXISTING SLAB

1/2

" DIAMETER EXPANSION ANCHOR W/ 4"

MIN. EMBED. HILTI KWIK BOLT TZ,

SIMPSON STRONGBOLT, POWERS

POWER-STUD+SD2 OR ARCHITECT

APPROVED EQUIVALENT

3/16

3/16

3/16

3/16

10'-6"

V.I.F.

REF RCP

1'

3/

4"

1/ 4"

8" 1' - 6 1/8" 8"

2'

FULLY SPRINKLERED

o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Office of Construction and Facilities Management th re e e ig h th s in c h o n e fo o t

EXPAND SPECIALTY

CARE

SUBMISSIONS

REVISIONS

ARCHITECT/ENGINEERS:

USFin Development, LLC 1105 West Weir Street Litchfield, IL 62056

CONSULTANTS

7260 SHADELAND STATION

INDIANAPOLIS, IN 46256-3957

TEL 317.547.5580 FAX 317.543.0270

www.structurepoint.com

United States Department of Veterans Affairs R. L. Roudebush VAMC 1481 West 10th Street Indianapolis, Indiana 46202

65% DESIGN DEVELOPMENT 1-23-15

95% CONSTRUCTION DOCUMENTS 2-25-15

11FY14100% SUBMITTAL DOCUMENTS 5-29-15

BID DOCUMENTS 5-10-17

/8

/2

:1 :4

P

M C

R e v it \2

\L o c a l C o p ie s \2

V

A In d y O n c o lo g y C

E N

T R

A L R ff a c k e n th a l.

rv t

SIXTH FLOOR-SECTIONS & DETAILS

05-10-17

V.A. 583-331

R. L. Roudebush VAMC, Indianapolis, IN

1-AS-301

FF APN

BIDDING DOCUMENTS

3/4" = 1'-0"

1-AS-301

1 6TH FLOOR-SECTION AT WINDOW

3/4" = 1'-0"

1-AS-301

3 6TH-COLUMN WRAP

3/4" = 1'-0"

1-AS-301

2 SHELF SECTION

3" = 1'-0"

1-AS-301

4 ACCORDIAN PARTITION SECTION DETAIL

D-6027

D-6013

C-6119C-6120

C-6124C-6123C-6122C-6121

D-6037D-6038

D-6009D-6008D-6007

D-6006

D-6040

D-6039

D-6036

D-6029

D-6005

D-6004

D-6003

D-6002

D-6001

D-6011

D-6032

D-6033

D-6034

D-6018

D-6023

D-6014

D-6022

D-6021

D-6026

D-6019

D-6035 D-6025 D-6024

D-6-C4

D-6-C5

D-6-C1

D-6028

D-6030

D-6020

D-6010

D-6017

D-6012

D -6

-C

D-6041

C-6118

001-06-N102 001-06-N111

001-06-N100

001-06-N101001-06-N103

001-06-N104

001-06-N105

001-06-N106

001-06-N107

001-06-N108

001-06-N109

001-06-N110001-06-N115 001-06-N116

001-06-N117

001-06-N118

001-06-N119

001-06-N120001-06-N121

001-06-N125

001-06-N126 001-06-N127

001-06-N128 001-06-N129

001-06-N130

001-06-N124

001-06-N114

001-06-N112

001-06-N122 001-06-N123

001-06-N131

001-06-N132 001-06-N133

001-06-N134 001-06-N135

001-06-N137

001-06-N136

001-06-N138

D-6-C2

001-06-N139 001-06-N140 001-06-N142 001-06-N141

001-06-N143 001-06-N144

001-06-N145

001-06-N146

001-06-N147 001-06-N148

001-06-N149

001-06-N150

001-06-N151

001-06-N152 001-06-N153 001-06-N154 001-06-N155

001-06-N156 001-06-N157

001-06-N158

001-06-N159

001-06-N160 001-06-N161

001-06-N164

001-06-N163

001-06-N162

001-06-N165

001-06-N168

001-06-N166

001-06-N167

001-06-N169

001-06-N170

001-06-N171

001-06-N131A

FULLY SPRINKLERED

o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Office of Construction and Facilities Management th re e e ig h th s in c h o n e fo o t

EXPAND SPECIALTY

CARE

SUBMISSIONS

REVISIONS

ARCHITECT/ENGINEERS:

USFin Development, LLC 1105 West Weir Street Litchfield, IL 62056

CONSULTANTS

7260 SHADELAND STATION

INDIANAPOLIS, IN 46256-3957

TEL 317.547.5580 FAX 317.543.0270

www.structurepoint.com

United States Department of Veterans Affairs R. L. Roudebush VAMC 1481 West 10th Street Indianapolis, Indiana 46202

65% DESIGN DEVELOPMENT 1-23-15

95% CONSTRUCTION DOCUMENTS 2-25-15

11FY14100% SUBMITTAL DOCUMENTS 5-29-15

BID DOCUMENTS 5-10-17

/8

/2

:1 :5

P

M C

R e v it \2

\L o c a l C o p ie s \2

V

A In d y O n c o lo g y C

E N

T R

A L R ff a c k e n th a l.

rv t

SIXTH FLOOR-SIGNAGE

05-10-17

V.A. 583-331

R. L. Roudebush VAMC, Indianapolis, IN

1-AS-401

FF APN

BIDDING DOCUMENTS

N

1/8" = 1'-0"

1-AS-401

1 SIXTH FLOOR SIGNAGE PLAN

SIGNAGE -6TH FLOOR

Sign Mark Sign Type Name Sign Type Proposed Content

001-06-N100 Automatic Fire Door IN-01.08 Room: Insert:

001-06-N101 Automatic Fire Door IN-01.08 Room: Insert:

001-06-N102 Fire Equipment Identification Sign (Flag) IN-01.31 Room: Insert:

001-06-N103 Primary Room Identification with Insert IN-04.03 Room: Insert:

001-06-N104 Primary Room Identification with Insert IN-04.03 Room: Insert:

001-06-N105 Primary Room Identification with Insert IN-04.03 Room: Insert:

001-06-N106 Primary Room Identification with Insert IN-04.03 Room: Insert:

001-06-N107 Automatic Fire Door IN-01.08 Room: Insert:

001-06-N108 Automatic Fire Door IN-01.08 Room: Insert:

001-06-N109 Primary Room Identification with Insert IN-04.03 Room: Insert:

001-06-N110 Primary Room Identification with Insert IN-04.03 Room: Insert:

001-06-N111 Primary Room Identification with Insert IN-04.03 Room: Insert:

001-06-N112 Fire Door IN-01.05 Room: Insert:

001-06-N112 Fire Door IN-01.05 Room: Insert:

001-06-N114 Fire Procedure Sign IN-01.03 IN CASE OF FIRE USE STAIRS. R.A.C.E.

001-06-N115 Perpendicular (Flag) Mount IN-13 Room: Insert:

001-06-N116 Fire Equipment Identification Sign (Flag) IN-01.31 Room: Insert:

001-06-N117 Secondary Room Identification with Insert IN-04.04 Room: Insert:

001-06-N118 Primary Room Identification with Insert IN-04.03 Room: Insert:

001-06-N119 Restroom Identification IN-09.03 Room: Symbol: Women-Men-Accessible Text: Restroom

001-06-N120 Secondary Room Identification with Insert IN-04.04 Room: Insert:

001-06-N121 Secondary Room Identification with Insert IN-04.04 Room: Insert:

001-06-N122 Automatic Fire Door IN-01.08 Room: Insert:

001-06-N123 Automatic Fire Door IN-01.08 Room: Insert:

001-06-N124 Fire Door IN-01.04 IN CASE OF FIRE USE STAIRS. DO NOT USE ELEVATORS.

001-06-N125 Secondary Room Identification with Insert IN-04.04 Room: Insert:

001-06-N126 Primary Room Identification with Insert IN-04.03 Room: Insert:

001-06-N127 Primary Room Identification with Insert IN-04.03 Room: Insert:

001-06-N128 Primary Room Identification with Insert IN-04.03 Room: Insert:

001-06-N129 Secondary Room Identification with Insert IN-04.04 Room: Insert:

001-06-N130 Secondary Room Identification with Insert IN-04.04 Room: Insert:

001-06-N131 Secondary Room Identification with Insert IN-04.04 Room: Insert:

001-06-N131A Secondary Room Identification with Insert IN-04.04 Room: Insert:

001-06-N132 Room Sign with Indicator IN-07.01-.03 Room: Insert:

001-06-N133 Room Sign with Indicator IN-07.01-.03 Room: Insert:

001-06-N134 Room Sign with Indicator IN-07.01-.03 Room: Insert:

001-06-N135 Room Sign with Indicator IN-07.01-.03 Room: Insert:

001-06-N136 Secondary Room Identification with Insert IN-04.04 Room: Insert:

001-06-N137 Secondary Room Identification with Insert IN-04.04 Room: Insert:

001-06-N138 Secondary Room Identification with Insert IN-04.04 Room: Insert:

001-06-N139 Room Sign with Indicator IN-07.01-.03 Room: Insert:

001-06-N140 Fire Equipment Identification Sign (Flag) IN-01.31 Room: Insert:

001-06-N141 Room Sign with Indicator IN-07.01-.03 Room: Insert:

001-06-N142 Room Sign with Indicator IN-07.01-.03 Room: Insert:

001-06-N143 Automatic Fire Door IN-01.08 Room: Insert:

001-06-N144 Automatic Fire Door IN-01.08 Room: Insert:

001-06-N145 Room Sign with Indicator IN-07.01-.03 Room: Insert:

001-06-N146 Room Sign with Indicator IN-07.01-.03 Room: Insert:

001-06-N147 Restroom Identification IN-09.03 Room: Symbol: Women-Men-Accessible Text: Restroom

001-06-N148 Room Sign with Indicator IN-07.01-.03 Room: Insert:

001-06-N149 Primary Room Identification with Insert IN-04.03 Room: Insert:

001-06-N150 Room Sign with Indicator IN-07.01-.03 Room: Insert:

001-06-N151 Room Sign with Indicator IN-07.01-.03 Room: Insert:

001-06-N152 Room Sign with Indicator IN-07.01-.03 Room: Insert:

001-06-N153 Room Sign with Indicator IN-07.01-.03 Room: Insert:

001-06-N154 Room Sign with Indicator IN-07.01-.03 Room: Insert:

001-06-N155 Primary Room Identification with Insert IN-04.03 Room: Insert:

001-06-N156 Secondary Room Identification with Insert IN-04.04 Room: Insert:

001-06-N157 Restroom Identification IN-09.03 Room: Symbol: Women-Men-Accessible Text: Restroom

001-06-N158 Primary Room Identification with Insert IN-04.03 Room: Insert:

001-06-N159 Secondary Room Identification with Insert IN-04.04 Room: Insert:

001-06-N160 Secondary Room Identification with Insert IN-04.04 Room: Insert:

001-06-N161 Secondary Room Identification with Insert IN-04.04 Room: Insert:

001-06-N162 Fire Equipment Identification Sign (Flag) IN-01.31 Room: Insert:

001-06-N163 Restroom Identification IN-09.03 Room: Symbol: Women-Men-Accessible Text: Restroom

001-06-N164 Secondary Room Identification with Insert IN-04.04 Room: Insert:

001-06-N165 Secondary Room Identification with Insert IN-04.04 Room: Insert:

001-06-N166 Fire Procedure Sign IN-01.03 IN CASE OF FIRE USE STAIRS. R.A.C.E.

001-06-N167 Stair Identification Sign IN-01.10 Room: Insert:

001-06-N168 Fire Door IN-01.05 Room: Insert:

001-06-N169 Stair Identification Sign IN-01.11 Room: Insert:

001-06-N170 Fire Equipment Identification Sign IN-01.02 Room: Insert:

001-06-N171 Fire Equipment Identification Sign (Flag) IN-01.31 Room: Insert:

WP1

WP2

WP3

WP4

CG1

CG2

WALL PROTECTION

HANDRAIL

BASE AS SCHEDULED

3'

R E

F R

C P

LEGEND:

D-6027

D-6013

C-6119C-6120 C-6118

C-6124 C-6123

C-6122C-6121

D-6037D-6038

D-6009 D-6008D-6007

D-6006

D-6040

D-6039

D-6036

D-6029

D-6005

D-6004

D-6003

D-6002

D-6001

D-6011

D-6032

D-6033

D-6034

D-6018

D-6023

D-6014

D-6022

D-6021

D-6026

D-6019

D-6035 D-6025

D-6024

D-6-C4

D-6-C5

D-6-C1

D-6028

D-6030

D-6020

D-6010

D-6017

D-6012

D-6041

D-6-C2

1 1 1

1 1

1 1

1 1 1 1

11 1

FULLY SPRINKLERED

o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Office of Construction and Facilities Management th re e e ig h th s in c h o n e fo o t

EXPAND SPECIALTY

CARE

SUBMISSIONS

REVISIONS

ARCHITECT/ENGINEERS:

USFin Development, LLC 1105 West Weir Street Litchfield, IL 62056

CONSULTANTS

7260 SHADELAND STATION

INDIANAPOLIS, IN 46256-3957

TEL 317.547.5580 FAX 317.543.0270

www.structurepoint.com

United States Department of Veterans Affairs R. L. Roudebush VAMC 1481 West 10th Street Indianapolis, Indiana 46202

65% DESIGN DEVELOPMENT 1-23-15

95% CONSTRUCTION DOCUMENTS 2-25-15

11FY14100% SUBMITTAL DOCUMENTS 5-29-15

BID DOCUMENTS 5-10-17

/8

/2

:1 :5

P

M C

R e v it \2

\L o c a l C o p ie s \2

V

A In d y O n c o lo g y C

E N

T R

A L R ff a c k e n th a l.

rv t

SIXTH FLOOR-WALL PROTECTION

05-10-17

V.A. 583-331

R. L. Roudebush VAMC, Indianapolis, IN

1-AS-402

FF APN

BIDDING DOCUMENTS

3/4" = 1'-0"

WALL PROTECTION LEGEND & ELEVATION

N

3/16" = 1'-0"

1-AS-402

1 6TH-CORNER GUARD & WALL PROTECTION LOCATION

1-AS-412

1-AS-412

1-AS-412

1-AS-412

1-AS-412

1-AS-412

1-AS-413

1-AS-413

1-AS-413

1-AS-413

1-AS-413

8A

8C

8B

8D

1-AS-413

9B

9C

9A

9D

1-AS-413

11 10

1-AS-414

1-AS-414

1-AS-414

1-AS-414

TYPICAL EXAM ROOM

SIMILAR

TO D-6023

SIMILAR TO

D-6014

TYP.

1-AS-414

1-AS-414

1-AS-413

1-AS-413

1-AS-421

1-AS-421

TYP.

TYP.

1-AS-414

1-AS-421

1-AS-417

1-AS-417

1-AS-417

1-AS-417

1-AS-417

1-AS-417

2-

SIM.

1-AS-417

TYP.

TYP.

1-AS-417

1-AS-417

ELECTRICAL

ROOM

D-6027

SOILED

UTILITY

D-6013

SOCIAL

WORKERS/

DIETICIAN

C-6120

PATIENT

NAVIGATION

C-6121

EXAM

3/BD

D-6037

EXAM

4/BD

D-6038

EXAM 12

D-6009

EXAM 11

D-6008

EXAM 10

D-6007

EXAM 9 /

SPECIALTY

PROCEDURE

D-6006

S.U.

D-6040

HAC

D-6039

EXAM

2/BD

D-6036

PATIENT

TOILET

D-6029

EXAM 8

D-6005

EXAM 7

D-6004

D-6003

EXAM 5

D-6002

C.U.

D-6001

PRIVATE

INFUSION

D-6011

EXAM

13/TELEHEALTH

D-6032

EXAM 14

D-6033

EXAM 15

D-6034

MED PREP

D-6018

C.U.

D-6017

PHARMACY-CHEMO

PREP-NON-STERILE

D-6015

UNISEX

TOILET

D-6023

PATIENT

TOILET

D-6014

WAITING-PRIVATE

D-6022

EXAM

1/BD

D-6035

CHECK-IN/OUT

D-6025

WAITING-GENERAL

D-6024

CORRIDOR

D-6-C3

O.I.T./BIOMED

D-6021

ELEV.

LOBBY

D-6-C5

ELECTRICAL

ROOM

D-6026

PRIVATE

INFUSION

D-6012

HAC

D-6019

NURSE

STATION

D-6016

CORRIDOR

D-6-C2

CORRIDOR

D-6-C1

CORRIDOR

D-6-C4

INFUSION

BAYS

D-6010

INFUSION

BAYS

D-6010

CASE

MANAGER

D-6028

CHARTING

ROOM

D-6030

PATIENT

TOILET

D-6031

PHARMACY-ORAL

CHEMO

D-6020

HEALTH

TECH

STATION

D-6041

SCALES

D-6-C1.A

W.C.

ALCOVE

D-6-C1.B

SCALE

D-6010.B

W.C.

ALCOVE

D-6010.C

W.C.

ALCOVE

D-6010.D

CORRIDOR

D-6-C1

NOURISHMENT

CENTER

D-6-C4.A

DRINKING

FOUNTAIN

D-6-C4.B

CLINICAL

MANAGER

C-6119

SOCIAL

WORKERS/

DIETICIAN

C-6120

STAFF

LOUNGE

C-6118

PATIENT

EDUCATION

C-6124

PATIENT

EDUCATION

C-6123

ONCOLOGY

COORDINATION

C-6122

PATIENT

NAVIGATION

C-6121

CORRIDOR

C-6-C1

ELEVATOR

ELEVATOR

ELEVATOR

PHARMACY-CHEMO

PREP-STERILE

D-6015A

P

M C

U s e r s J u l i e D o c u m e n t s V

A

R o u d e b u s h a n d f l o o r s

R e n o v a t i o n w

J u l i e r v t

SIXTH FLOOR - ONCOLOGY INTERIOR

ELEVATION KEY PLAN

5-10-17

1-AS-411

A Henry A Henry

N

1/8" = 1'-0"

1-AS-411

1 SIXTH FLOOR - INTERIOR ELEVATION KEY PLAN

Revision #

FULLY SPRINKLERED

o n e e i g h t h i n c h o n e f o o t 1 t h r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Drawing

Title

Approved: Project

Director

Project

Title

Date

Location

Checked

Building

Number

Project

Number

Drawing

Number

Drawn t h r e e e i g h t h s i n c h o n e f o o t

EXPAND SPECIALTY

CARE

SUBMISSIONS

REVISIONS

USFin Development, LLC

1105 West Weir Street

Litchfield, IL 62056

7260 SHADELAND STATION

INDIANAPOLIS, IN 46256-3957

TEL 317.547.5580 FAX 317.543.0270

www.structurepoint.com

United States Department of

Veterans Affairs

R. L. Roudebush VAMC

1481 West 10th Street

Indianapolis, Indiana 46202

65% DESIGN DEVELOPMENT 1-23-15

95% CONSTRUCTION DOCUMENTS 2-25-15

11FY14

100% SUBMITTAL DOCUMENTS

5-29-15

BID DOCUMENTS

5-10-17

P

M C

R e v i t L o c a l

C o p i e s V

A I n d y

O n c o l o g y C

E N

T R

A L R a n o r d s t r o m r v t

V.A. 583-331

R. L. Roudebush VAMC, Indianapolis, IN

BIDDING DOCUMENTS

N

N

SIXTH FLOOR KEY PLAN

AREA 'A' AREA

'B'

TRUE NORTH

PLAN NORTH

NOTE: Not all symbols used on all Sheets

= DUPLEX RECEPTACLE

= QUADRUPLEX RECEPTACLE

= SIMPLEX RECEPTACLE

= CABLE TV RECEPTACLE

= NURSE CALL

= WALL SWITCH

= TELEPHONE JACK

= FA SPEAKER STROBE 80" AFF

= DUPLEX RECEPTACLEE

= NURSE CALL DOME LIGHT

= MEDICAL GAS - AIR

= MEDICAL GAS - VACUUM

= MEDICAL GAS - OXYGEN

= DATA JACK

T

= THERMOSTAT

JSN…

This is the start of the file's text. The full file is on GovTribe.