TECH LIBRARY 1 SVPP Supplier Manuals Everight Alliance S1A_datasheet_022610.pdf

PDF 139 KB Posted

Attached to
Launch Operations Support Contract (LOSC) Request for Proposal (RFP) – FINAL Federal contract opportunity
Solicitation number
FA4610-22-R-0001
Issued by
Department of the Air Force Space Command

About this file

This request for proposal solicits offers for launch operations support contract services at Vandenberg Air Force Base in California. Offerors are to submit proposals by January 27, 2022 to provide facilities support services with a NAICS code of 561210 and small business size standard of $41.5 million. The performance work statement and appendices outline requirements for supporting launch operations, including government furnished property. Attachments also provide applicable Department of Labor wage determinations and collective bargaining agreements. Questions regarding the final RFP are due by January 4, 2022.

View the file

Other files for this federal contract opportunity

Other files attached to Launch Operations Support Contract (LOSC) Request for Proposal (RFP) – FINAL, newest first.
File Type Posted
L-4_Section L dtd 19Nov21_Revised_30Aug22.pdf PDF
L-5_Section M dtd 19Nov21_Revised_30Aug22.pdf PDF
L-4_Section L dtd 19Nov21_Revised_04Feb2022.pdf PDF
RFP Amendment 0004 Conf SF33 - FA461022R00010004.pdf PDF
RFP Amendment - FA461022R00010002 Conf SF33 20220118.pdf PDF
Atch 8 SCA WD 2015-5637_Rev 19_20211020_12Jan2022.pdf PDF
L-2_SubcontractTeamingPartnerConsent_Revised_11Jan2022.pdf PDF
Solicitation - FA461022R0001_20211209.pdf PDF
L-2_SubcontractTeamingPartnerConsent_Final_9Dec2021.pdf PDF
Atch 2_Appendix B_Antenna Tower Responibility List_Final_9Dec2021.pdf PDF
Atch 2_Appendix G_Environmental Requirements_Final_9Dec2021.pdf PDF
Atch 2_Appendix J_Contract Data Requiremetns List (CDRL) Deliverables_Final_9Dec2021.pdf PDF
Atch 3_LOSC_GFP Attachment_9Dec2021.pdf PDF
Atch 7 DB WD CA20210018_Mod 28_20211203.pdf PDF
Atch 11 2019-2024 CBA_Redacted_w_Appendix A.pdf PDF
Atch 11 CBA-2019-12949.pdf PDF
Atch 12 DB WD CA20210014_Mod 14_20211029.pdf PDF
Exhibit A_CDRL_A001_Corrosion Prevention and Control Plan_Final_9Dec2021.pdf PDF
Exhibit A_CDRL_A006_Technical Report Waster Water Discharge_Final_9Dec2021.pdf PDF
Exhibit A_CDRL_A009_Program Management Plan_Final_9Dec2021.pdf PDF
Exhibit A_CDRL_A015_Solid Waste Report_Final_9Dec2021.pdf PDF
Exhibit A_CDRL_A016_HMMP Report_Final_9Dec2021.pdf PDF
Exhibit A_CDRL_A019_Cost Peformance Report_Final_9Dec2021.pdf PDF
Exhibit A_CDRL_A021_JOCAS Reports_Final_9Dec2021.pdf PDF
Exhibit A_CDRL_A023_RCM Plan_Final_9Dec2021.pdf PDF
Exhibit A_CDRL_A024_Work Order Status Report_Final_9Dec2021.pdf PDF
Exhibit A_CDRL_A026_System Safety Program Plan_Final_9Dec2021.pdf PDF
TECH LIBRARY 1 SVPP Supplier Manuals Rockwell 1756-td002_-en-e.pdf PDF
TECH LIBRARY 1 Drawings - As Builts - ACGAL020E000000.pdf PDF
TECH LIBRARY 1 Func Desc Instrux - Control - ACGAL020S000002_B.pdf PDF
TECH LIBRARY 1 SVPP Supplier Manuals EthosEnergy Speed Input Module II User Manual.pdf PDF
TECH LIBRARY 1 SVPP Supplier Manuals Rockwell 1756-OB32 Contact Output Module.pdf PDF
TECH LIBRARY 1 SVPP Supplier Manuals Axiomatic 0-200mA to 4-20mA Converter.pdf PDF
TECH LIBRARY 1 SVPP Supplier Manuals Phoenix Contact 3044102 (1).pdf PDF
TECH LIBRARY 2-8310-PV-181-VTE-20210225.pdf PDF
TECH LIBRARY 6-PTO-13968-R2-Final.pdf PDF
TECH LIBRARY 13-CDRL_A005_FUGITIVE REPORT_example.pdf PDF
TECH LIBRARY 13-CDRL_A025_Generator Testing and Maint Report_example.pdf PDF
Exhibit A_CDRL_A011_Quality Management Plan_Final_9Dec2021.pdf PDF
Exhibit A_CDRL_A012_Requisition Summary_Final_9Dec2021.pdf PDF
L-5_Section M dtd 19Nov21_Final_9Dec2021.pdf PDF
Atch 6_LOSC_DD254_9Dec2021.pdf PDF
Atch 11 Appendix B - Wage Rate Tables (2019-2024)_Redacted.pdf PDF
Exhibit A_CDRL_A002_GFP Inventory Report_Final_9Dec2021.pdf PDF
Exhibit A_CDRL_A010_Daily Maintenance and Repair Schedule_Final_9Dec2021.pdf PDF
Exhibit A_CDRL_A014_Cathodic Protection Booklet_Final_9Dec2021.pdf PDF
Exhibit A_CDRL_A020_Contract Funds Status Report_Final_9Dec2021.pdf PDF
Exhibit A_CDRL_A027_Facility Assessment Report_Final_9Dec2021.pdf PDF
TECH LIBRARY 1 SVPP Supplier Manuals Rockwell 1444-um001_-en-p.pdf PDF
TECH LIBRARY 1 SVPP Supplier Manuals Rockwell 1407-CGCM-DLR.pdf PDF
Show all 50

Launch Operations Support Contract (LOSC) Request for Proposal (RFP) – FINAL has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

The Everight S1A DIN rail module ends the usual difficulties that accompany AC-LVDT set up with a built-in null indicator and simple front panel pushbuttons to set zero and full scale. Engineered to work with the widest range of AC-LVDTs and inductive half-bridges, the S1A module monitors LVDT operation and indicates most common failures. The S1A offers a choice of four excitation frequencies and eight analog DC outputs, as well as an RS-485 digital communications port. These features make the Everight S1A the world leader in AC- LVDT signal conditioning…

• Smart setup with 2 front panel push buttons --- NO POTS

• Built-in null indicator: LEDs and separate DC null voltage output

• Choice of 1, 3, 5, or 10 kHz nominal excitation frequencies

• Use with 3-, 4-, 5-, or 6-wire LVDTs and inductive half-bridges including 3-wire GE LVRTs

• Choice of 6 DC voltage outputs and 2 current loop outputs

• 40 dB range of FS outputs from LVDT: 50 mV rms to 5 Volts rms

• Fail-safe master /slave syncing eliminates beat frequencies

• 15 - 32 Volts DC operation, 80 mA maximum operating current.

• Self-diagnostic for LVDT winding failures or cable disconnection

• Independent failure warning flag via open collector output

• Digital communications link via

RS-485 multi-drop bus with up to 16 individual module addresses

• Hot swappable: set-up can be saved /reloaded via RS-485 port

• Color coded plug-in connections to 22.5 mm wide DIN-rail module

• TWO (2) YEAR warranty instead of industry standard (1) year

Everight Sensors Corporation

102 Commerce Drive, Unit 8 Moorestown, New Jersey 08057 USA www.everightsensors.com info@everightsensors.com 856-727-9500 http://www.everightsensors.com/ mailto:info@everightsensors.com

Everight Sensors S1A LVDT Signal Conditioner Specifications Operating power: +15 to +32 V DC (+24 V DC nominal), 60 mA max. at 24 V DC;

+15 V DC and -15 V DC for -10 V to +10 V DC bipolar output

Excitation voltage: 3.0 Vrms sine wave push-pull drive nominal (factory default)

4.5 Vrms sine wave push-pull drive via on-board jumper shift

1.5 Vrms single ended drive for low impedance (100 -150 Ω) primary

Excitation frequencies: 1 kHz, 3 kHz, 5 kHz, 10 kHz (nominal)

Master/slave syncing: Master output couples up to fifteen slave inputs; if original master fails, new master is automatically generated for fail-safe excitation control.

LVDT AC Output Signal: 50 mVrms to 5000 mVrms at LVDT's full scale position

Analog DC Outputs: 0 - 5 V, 1 - 5 V, 0.5 - 4.5 V, 0 -10 V, -10 to +10 V, 0.5 - 9.5 V, 0 -20 mA sourcing, 4 -20 mA sourcing

Loop resistance: 850 Ω max (current loop output mode, 24 V DC supply)

Output non-linearity: ≤0.025% of Full Span Output (FSO)

Frequency response: -3 dB at 10% of excitation frequency (nominal) (standard: DS2-4 off) -3 dB at 10 Hz (nominal) (low noise setting: DS2-4 on)

Noise and ripple: ≤2 mVrms (voltage output), or ≤4 µArms (current loop output.)

Fault indication: Loss of excitation, open primary or secondary, LVDT disconnected

Fault output: LED indicators, open collector output, 50 mA, 26.5 V DC max.

Null detection: Front panel LEDs, ± 30 mV threshold out of ≈ ±1.6V signal level

Null output: LEDs, DC null voltage signal (≈ ±3 V DC = ±FS)

Operating Temperature: -20 ºC to +75 ºC

Zero set: Front panel push button or RS-485 command

Full Scale set: Front panel push button or RS-485 command

Digital interface: RS-485 2-wire multi-drop network, 16 addresses

S1A Module Outline Dimensions